Home

Combi / Mastercheck Instructions PDF

image

Contents

1. Automatic battery monitor ing Single hand operation for testing socket outlets using clip connector for test pro bes Phase testing Combi Check 1 2 only Visual and accoustic indicator Combi Check 1 2 only Selectable test probe light Combi Check 1 2 only Master Check 3 2 Test probe guard Test probes Voltage indicator LED Pushbutton Clip connector LED s for indicating DC and AC voltage polarity continuity testing Battery compartment 880809 Q A Safety Instructions E The voltage tester must only be used within the specified rated voltage range The provisions con tained in DIN VDE 0105 Part 100 and EN 50110 1 regarding the use of volt age testers stipulate that just before testing for iso lation from supply the voltage tester must be checked for proper work ing order If the indicator fails to operate during this check the voltage tester must not be used E Indication that the upper limit for extra low voltages ELV has been exceeded only serves as a warning to the user and not as a measurement reading E Due to the high input resistance the capacitive and inductive voltages may be indicated E When testing hold the voltage tester by its hand les only Do not touch the test electrodes Only per form 2 pole voltage tests E Before using the voltage tester in places where noise levels are high first check whether the accoustic test signal is aud
2. A at 400 V Continuity testing Continuity lt 500 kOhm Single pole phase testing Continuity at voltages Combi Check 1 2 only gt 90 V AC acoustic signal Temperature range 10 C to 55 C Battery life approx 1500 operations Battery type 2 x micro 1 5 V AAA Alkaline do not use rechargeable batteries Enclosure IP 50 Approval to EN 61243 3 VDE 0682 Part 401 Weight 135 g Battery and Function Test Battery installation Open the battery compart ment using a screwdriver or a coin With the rear side of the unit facing up turn the catch clockwise through 45 to unlock Now pull the bat tery compartment out as far as the stop Install batteries as indicated do not use rechargeable batteries To close the battery compart ment push the battery com partment as far as it will go into the housing and lock the compartment in place by turning the catch anticlock wise through 45 WARNING Voltage tester must not be used with the battery compartment open Function test battery test With the test probes shorted and pushbutton pressed the entire LED step display must come on briefly leaving only the 6 V step indicator on An acoustic signal will also sound If the 6 V step indi cator flashes during this test change the batteries at the next opportunity possible The LED step display will flash while conducting further voltage continuity checks to remind you t
3. Spannungspr fer Combi Check 1 2 Master Check 3 2 d z x 2 i Bedienungsanleitung S Operating instructions Gebruiksaanwijzing Mode d emploi Istruzioni per Puso Instrucciones de manejo Bruksanvisning Brugsanvisning K ytt ohje e88909980 Bruksanvisning STERNEL Zuschaltbare Priifspitzenbeleuchtung NI ei CE Konformit tserkl rung Das Produkt erf llt die Niederspannungsrichtlinie Funktionsgarantie Dieses STEINEL Produkt ist mit gr ter Sorgfalt hergestellt funktions und sicherheitsge pr ft nach geltenden Vor schriften und anschlie end einer Stichprobenkontrolle unterzogen Die Garantiefrist betr gt 36 Monate und beginnt mit dem Tag des Verkaufs an den Verbraucher Wir beseitigen M ngel die auf Material oder Fabrikationsfehlern beruhen die Garantieleistung erfolgt durch Instandsetzung oder Austausch mangelhafter Teile nach unserer Wahl Eine Garantieleistung entf llt f r Sch den an Verschlei teilen f r Sch den und M n gel die durch unsachgem e Behandlung oder Wartung auftreten sowie f r Bruch bei Sturz nur Combi Check 1 2 Die Pr fspitzenbeleuchtung kann manuell durch Dr cken der Taste und einmaliges Kurzschlie en der Pr fspitzen eingeschaltet werden Die Beleuchtung bleibt nur f r die Dauer der Tastenbet ti gung eingeschaltet 73 23 EWG
4. anu facturing defects This war ranty undertaking shall be performed by the repair or replacement of the defective parts at our own discretion This warranty shall not cover damage to wearing parts or damage and faults caused by incorrect operation or maintenance Breakage due to a fall is also not covered 14 73 23 EEC and EMC Directive 89 336 EEC Further consequential dama ge to external items is ex cluded Claims under warranty shall only be accepted if the pro duct is sent fully assembled and well packed complete with sales slip or invoice date of purchase and dea ler s stamp to the appro priate Service Centre or handed in to the dealer within the first 6 months Repair Service Our Customer Service Department will repair faults not covered by warranty or after the warranty period Please send the product well packed to your nearest Service Centre 86 month Mode d emploi Cher client Nous vous remercions de la confiance que vous avez t moign e STEINEL en achetant ce testeur de ten sion Vous avez choisi un article de tr s grande qualit fabriqu teste et conditionn avec le plus grand soin Le testeur de tension vous offre les fonctions suivantes affichage de tensions con tinues et alternatives affichage de la polarite test de continuite avec poussoir Description de l appareil Combi Check 1 2 Protection des pointes de test Pointes de te
5. hat the batteries need changing 11 Voltage testing Apply the test probes to the potential points you wish to test E For DC voltage testing the test probe on the display handle represents the positive pole and the small test probe the neg ative pole E The positive and the neg ative diode of the 6 V volt age step will light up simultaneously for AC voltage E The entire LED step dis play will briefly light up at the start of each voltage test Continuity testing Before conducting a con tinuity test in electrical systems first switch off external voltage sources and where applicable discharge capacitors Short the test probes and keep button pressed Contact the test object with the test probes Contact the test object The level of voltage pre sent is indicated by the LED s lighting up as far as the step level of voltage present An acoustic indi cation is also given for Combi Check 1 2 with the test probes If contact resistance is lt 500 kOhms the 6 V diode will light up An acoustic indication is also given for Combi Check 1 2 Impressed external voltages will be indicated despite the continuity test and will not harm the tester 12 Semiconductor testing When the button is pressed during polarity dependent continuity testing the internal test voltage source is switched to the test probes The display handle repre sents the p
6. ible E The LEDs start to glow at 80 85 of designated voltage 10 E Reliable indication is only assured over a tempera ture range of 10 C to 55 C E The voltage tester must be checked for proper work ing order shortly before and after testing for isola tion from supply If this check reveals any failure of the tester to indicate one or more steps or ifthe voltage tester fails to show that it is ready for opera tion it must not be used E The voltage tester and its accessories must not be dismantled by unauthor ized persons E The tester must be stored in a dry and clean place E The tester must not be used in wet conditions e g condensation or rain IP 50 E Within its maximum ON duration the device may be exposed for up to 30 seconds to the maximum rated voltage of the indi cated range E Indicator legibility may be impaired in adverse light conditions e g in sunlight E WARNING Voltage tester must not be used with the battery compartment open Technical Specifications L x W x H 230 x 55 x 34 mm Dimensions Rated voltage range Combi Check 1 2 6 690 V AC DC Master Check 3 2 6 400 V AC DC Frequency range 0 100 Hz AC display from f gt 2 Hz Voltage surge proof Combi Check 1 2 6 KV Master Check 3 2 4 KV Input resistance gt 300 kOhm Input current Combi Check 1 2 Is lt 2 5 mA at 690 V Master Check 3 2 Is lt 2 5 m
7. ositive pole and the small handle the negative pole If continuity is given the 6 V diode illuminates An acoustic indication is also given for Combi Check 1 2 Phase testing Combi Check 1 2 only WARNING Phase testing cannot be performed in unfavourable locations e g on ladders with wooden rungs or in rooms with insu lated floor coverings and in AC voltage systems not properly bonded to earth E To perform the phase test contact the small test probe with the phase gt 90 V AC of the AC voltage system and touch the phase tester contact on the indicator handle with your thumb The 6 V step indicator and will light up upon phase contact and an acoustic signal is also given 13 Selectable test probe light Combi Check 1 2 only The test probe light can be switched on manually by pressing the button and briefly shorting the test pro bes The light only remains on while the button is pressed C Declaration of Conformity This product complies with Low Voltage Directive Functional Warranty This STEINEL product has been manufactured with great care and its operation and safety have been tested in conformity with the current regulations Production is also submitted to final ran dom sample testing The warranty period is 36 months starting on the date of sale to the user We undertake to remedy faults caused by material or m
8. st T moin de tension DEL Poussoir Cran Diodes pour l affichage de tensions continues et alternatives polarit test de continuit test de phase uni quement Combi Check 1 2 Compartiment a piles Avertisseur sonore pour signal acoustique uniquement Combi Check 1 2 Eclairage des pointes de test uniquement Combi Check 1 2 908080 Elei detection de tensions gt 50 V C A 120 V C C m me sans piles contr le automatique des piles utilisation d une seule main pour les tests de prises de courant par enclenchement des pointes de test test de phase uniquement Combi Check 1 2 affichage visuel et signal acoustique uniquement Combi Check 1 2 clairage d brayable des pointes de test unique ment Combi Check 1 2 Master Check 3 2 Protection des pointes de test Pointes de test Temoin de tension DEL Poussoir Cran Diodes pour l affichage de tensions continues et alternatives polarit test de continuit Compartiment a piles 8808 15
9. und die EMV Richtlinie 89 336 EWG Weitergehende Folgesch den an fremden Gegenst nden sind ausgeschlossen Die Garantie wird nur gew hrt wenn das unzerlegte Ger t mit Kassenbon oder Rechnung Kaufdatum und H ndler stempel gut verpackt an die zutreffende Servicestation ein gesandt oder in den ersten 6 Monaten dem H ndler ber geben wird Reparaturservice Nach Ablauf der Garantiezeit oder M ngeln ohne Garantie anspruch repariert unser Werkservice Bitte das Produkt gut verpackt an die n chste Servicestation senden 36 Monate GARANTIE Instructions for Use Dear Customer Congratulations on purchas ing your new STEINEL Voltage Tester and thank you for the confidence you have shown in us You have cho sen a high quality product that has been manufactured tested and packed with the greatest care The step volt age tester is capable of the following functions DC and AC voltage indica tion Polarity indication Continuity testing with pushbutton Description Combi Check 1 2 Test probe guard Test probes Voltage indicator LED Pushbutton Clip connector LED s for indicating DC and AC voltage polarity continuity testing phase testing Combi Check 1 2 only Battery compartment Accoustic indicator buz zer Combi Check 1 2 only Test probe light Combi Check 1 2 only G amp 6 00 GO Voltage detection gt 50 V AC 120 V DC even with out batteries