Home

Pulsed Ionizing Bar Installation and Operating Instructions

image

Contents

1. MA 01752 508 485 7390 Fax 508 480 0257 Website ESDSystems com 2009 DESCO INDUSTRIES INC TB 6115 Page 2 of 4 Employee Owned To change the unit network three digit address and enable disable the remote control use the following procedure 12 3 qvAaA gt Press lt and gt buttons simultaneously to go into the ionizer setup mode HEH E 0 8 P lt VA gt The unit will display Prog momentarily and go to the period setting menu Press the lt button to go back to the address menu HEHE E 12 4A lt VA gt The last digit of the address will be flashing Press VW or A buttons to change the last digit 0 to 9 Press the lt button to go to the second digit of the address HEHE E 15 4A lt VA gt The second digit of the address will be flashing Press W or A buttons to change the second digit O to 9 Press the lt button to change first digit of the address EE E 2 54A oe ae The first digit of the address will be flashing Press V or A buttons to change the first digit 0 lt VA gt to 2 Press the lt button to go to the enable disable remote menu BEE Note address 000 is reserved as a network broadcast command Do not use OF Fr After pressing the lt button to go to the enable disable remote menu the display will show qvAa gt OFF r for off remote default setting This means that the unit will not respond to the remote control To enable the remote press V or A buttons and the di
2. 4 of 4 Employee Owned
3. ESD SYSTEMS com INSTRUCTIONS MANUAL TB 6115 Pulsed lonizing Bar Installation and Operating Instructions Figure 1 62406 Pulsed lonzing Bar The Pulsed lonizing Bar combines the effectiveness of pulsed DC ionization with the ease of adjustability communication capability and the flexibility of a micro controller based design to produce a versatile ionization system The Pulsed lonizing Bar uses pulses of positive and negative ions to produce extended ionization coverage with or without forced air flow Optional communication port network software and remote control ZVI IR for adjustments are available Installation Remove the Pulsed lonizing Bar from the carton and inspect for shipping damage Included with the unit should be Pulsed lonizing Bar Earth grounding wire 24V 350mA power supply Emitter point cleaner Hanging Kit optional ork WD Setup and Operation The unit is powered by the 24V DC supply and begins working when plugged in Note the earth grounding wire must be connected to the terminal on the unit and to earth ground for the PIB3000 to work properly The RS485 input output ports for the optional software package are located on the back side towards the right end of the unit The control buttons along with the LED display are located on the front side towards the right end of the unit The control buttons are numbered left to right as shown in Figure 1 Button 1 lt d correspond
4. s to Go Back button 2 W corresponds to Decrease button 3 A corresponds to Increase and button 4 P corresponds to Go Forwara When the Pulsed lonizing Bar is first powered on the unit will display its default address 000 ha Made in Amenta Specifications Balance User adjustable Dimensions 1 5H X1 5W X 1 2 4 OR6 FT L Weight 1 1 5 2 5 OR 3 5 LBS Respectively Emitter Points Machined tungsten High Voltage Power Supply 5kV Input Power 24V DC 350mA lon Emission Pulsed DC open loop control Ozone Less than 0 05ppm Cleaning Procedure To clean the Pulsed Ionizing Bar first turn off and unplug the unit The emitter points are easily cleaned using Semtronics part number S204 200 emitter point cleaner To clean any dirt off of the bar itself using clean compressed air is recommended or wiping with any suitable material ESD Systems com 432 Northboro Road Central Marlboro MA 01752 508 485 7390 Fax 508 480 0257 Website ESDSystems com TB 6115 January 2009 Page 1 of 4 2009 DESCO INDUSTRIES INC Employee Owned VAP LED DISPLAY Figure 2 Set Up Mode Pr og Press lt and gt buttons simultaneously to go into the ionizer setup mode When the buttons are A VA b gt released the unit should beep once and Prog should appear momentarily on the LED display The display will then show the period setting EE E 1 6P Press V or A buttons to adj
5. shipping instructions and address Include a copy of your Original packing slip invoice or other proof of date of purchase Any unit under warranty should be shipped prepaid to the Semtronics factory Warranty replacements will take approximately two weeks If your unit is out of warranty Semtronics will quote repair charges necessary to bring your unit up to factory standards Call Customer Service at 909 627 8178 for proper shipping instructions and address Ship your unit freight prepaid WARRANTY EXCLUSIONS THE FOREGOING EXPRESS WARRANTY IS MADE IN LIEU OF ALL OTHER PRODUCT WARRANTIES EXPRESSED AND IMPLIED INCLUDING MERCHANTABILITY AND FITNESS FORA PARTICULAR PURPOSE WHICH ARE SPECIFICALLY DISCLAIMED The express warranty will not apply to defects or damage due to accidents neglect misuse alterations operator error or failure to properly maintain clean or repair products LIMIT OF LIABILITY In no event will Semtronics or any seller be responsible or liable for any injury loss or damage direct or consequential arising out of the use of or the inability to use the product Before using users shall determine the suitability of the product for their intended use and users assume all risk and liability whatsoever in connection therewith ESD Systems com 432 Northboro Road Central e Marlboro MA 01752 508 485 7390 Fax 508 480 0257 Website ESDSystems com 2009 DESCO INDUSTRIES INC TB 6115 Page
6. splay will read On r ee for on remote Alarm Conditions The Pulsed lonizing Bar is able to detect low and high input voltages It will sound a continuous tone audible alarm during all alarm conditions H P If the unit detects that the input voltage is too low it will display LO P for low power and VA gt sound the audible alarm If the unit detects that the input voltage is too high it will display EEEn HI P for high power and sound the audible alarm ESD Systems com 432 Northboro Road Central Marlboro MA 01752 508 485 7390 Fax 508 480 0257 Website ESDSystems com 2009 DESCO INDUSTRIES INC TB 6115 Page 3 of 4 Employee Owned TECHNICAL SUPPORT ESD Systems 432 Northboro Road Central Marlboro MA 01752 Tel 508 485 7390 Fax 508 480 0257 NOTE Unauthorized servicing or modifications to your monitor will void the product warranty and may create dangerous conditions Servicing should be performed only at the factory or by a Semtronics approved technician LIMITED WARRANTY Semtronics expressly warrants that for a period of one 1 year from the date of purchase Semtronics 62260 ZVI IR will be free of defects in material parts and workmanship labor Within the warranty period a unit will be tested repaired or replaced at our option free of charge Call Customer Service at 909 627 8178 Chino CA or 781 821 8370 Canton MA for Return Material Authorization RMA and proper
7. ust the period from 0 1P shortest 0 1 seconds to 10P A VA gt longest 10 seconds for acceptable balance swing and satisfactory decay time Press the gt button to go to the next menu The next menu is for the duty cycle adjustment EEE g y Cy J Place the charge plate monitor under the middle of the ionizing bar The number shown represents the duty cycle The duty cycle is the percentage of time that the positive supply is 9 0 on For example for a period of 10 seconds selecting a 40 duty cycle corresponds to the A VA es positive supply being on for 4 seconds and negative being on for 6 seconds Press and hold SEE the V button smaller duty cycle more negative or the A button larger duty cycle more positive to adjust the balance for an even swing For finer adjustment use single clicks of the buttons to change in one percent increments Press the button to save and exit Press the lt button to go to the previous menu V E To save and exit at any time during the setup mode press lt and gt buttons simultaneously A gt The Pulsed lonizing Bar will save all settings and return to normal operation The Pulsed lonizing Bar will display SAVE and the status of the buttons On b for on buttons meaning E that the buttons are enabled then the unit address b q VA P Note the control buttons can be disabled OFF b by the ZVI IR remote control only ESD Systems com 432 Northboro Road Central Marlboro