        NETWORK OPERATING INSTRUCTIONS 12pCO DOMINO System
         Contents
1.   Istruzioni per la messa in rete DOMINO   operation for DOMINO network    THE AIRVOLUTION j        Thermocold    THE AIRVOLUTION    NETWORK OPERATING  INSTRUCTIONS  12pCO DOMINO System    Hydronic modular groups with scroll  compressors       GUDOM DOEL REVOO 0613 UK    Thermocold Istruzioni per la messa in rete DOMINO   operation for DOMINO network    THE AIRWVOLUTION       1  Netwok Configuration    The software provides customizing the network configuration based on the number of units chiller  heat  pump and only chiller units  The software provides for the assignment of addresses to PCOS cards on the  network  The addresses to be assigned to the PCO units in the network are the progressive values ranging  from 1  for the Master unit  up to 12  In particular  in the case of a network of machines composed by  machines chiller and heat pump  the only Chiller units will receive the last P Lan network addresses  for  example a configuration with 7 units of which 4 heat pumps and 3 only chiller  the 4 heat pumps must have  address  respectively  1  2  3 and 4  while only chiller units respectively 5  6 and 7  This is because during  winter  the operation mode will be only heat pumps and the master must necessarily be one of them     2  Address Configuration Operating Instructions    We show below an example of an address configuration using the accessory kit DOMINO GENIUS     e disconnect the network connector for each machine  e connect the terminal to the pCO  e give power 
2.  system     At this point the main menu mask will appear  To view SLAVEs press the INFO button and in the mask that  appears  press ENTER and enter the address of the unit to control and press ENTER again to confirm  To  return from a SLAVE to MASTER  you must log into the INFO mask and set address 1     4     At the end of the addressing operation  you can then proceed to complete the configuration steps of the  network  In the C4 mask in the manufacturer branch of the MASTER card  you can enter the number of  units only chiller and the number of heat pump units of the network  and in the C1 mask you can enable  the B2 probe  outlet water temperature system      For modular units ordered with MASTER  amp  SLAVE configuration  the customer must only perform the  procedure in step 3      GUDOM DOEL_REV00_0613_UK    
3. to the board      press the ENTER key and the two directional buttons for more than 5 seconds  the following screen  will appear    Display address  setting    I O Board       e change the address on the keypad press ENTER  change the value to 0 and press ENTER again to  confirm  e power off the Pco card      Power up again Pco and simultaneously press the ALARM key and the Up arrow until the  appearance of the mask    pLan address   UP  increase    DOWN  decrease  ENTER  save  amp  exit       e    Set 1 for the Master address by pressing UP and DOWN buttons and then press ENTER to confirm    GUDOM DOEL_REV00_0613_UK    i Thermocold Istruzioni per la messa in rete DOMINO   operation for DOMINO network    THE AIRWVOLUTION       e Remove power to the board Pco   e Disconnect the GENIUS terminal and connect it to the other units and repeat step 2  by assigning  the addresses according to the rules written above   e After these operations reconnect the GENIUS terminal to the M aster unit   3    e Give power to the Pco board by simultaneously pressing the ENTER and the arrow keys for 5  seconds  this screen will reappear    Terminal config  Press ENTER    to continue       e tochangethe keypad address press ENTER  the following screen will appear    P 01 Adr  Priv Shared  Trml 32 sh  Trm2 02   Trmi             e set address 16 and in the adjacent field you must set SH  share  and press ENTER to confirm   After configuring all units  restore the network connections and power up the
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
Formation clinique des physiciens médicaux se  StirLITE Especificacion Tecnica  Modèles Mise sous tension Guide de démarrage rapide  Not require for standard ANSI/UL 60065  Descargar Ficha técnica  COMIST 180 COMIST 250 COMIST 300  This manual contains information regarding the safe installation and    Atlantis Land A02-RAV211 User's Manual  Plasma/LCD TV Wall Bracket 42"-80" CW    Copyright © All rights reserved. 
   Failed to retrieve file