Home

Operating Instructions - York Survey Supply Centre

image

Contents

1. Nothing else measures up Prospect House George Cayley Drive Clifton Moor York England YO30 4XE Tel 44 0 1904 692723 Fax 44 0 1904 690385 E Mail sales yorksurvey co uk YorkSurvey for secure online ordering of all our products Ref operat98 instructions 15 37203 qxp 05 01 15 Survey Supply USB Microscope Code 37203 Operating Instructions ITN York Survey Supply Centre 2015 Prior to use the user should read the following instructions and familiarise themselves with the functions of the microscope The microscope is covered for 1 year warranty against any manufacture defects When not in use keep the microscope in its box to prevent damage Never open or try to repair the microscope Never use the microscope for medical purposes Do not dispose of the product into industrial or consumer waste Supplied USB Microscope with a hard wired USB connection cable Support stand Image processing software Instructions for use The USB Microscope is a multipurpose microscope with a USB interface The microscope provides visual inspection of hard to see places things with the ability to view capture and store still and video images Adjustable light intensity focus and magnification offer clear and sharp images Technical Specifications Image sensor 2 megapixels Video capture resolution 1600 x 1200 1280 x 1024 64x 480 320 x 240 Still image capture resolution
2. The first is for help using Digi View second lets you change the settings You can send your photos and videos by email delete them using the rubbish bin and print them out Troubleshooting 1 The picture is not clear Clean the camera lens with a soft and dry cloth 2 There are black bars on the picture Delete anything that could be effecting the camera 3 The picture is too bright or too dark or has very low contrast Adjust the settings to change the contrast brightness etc until it meets your preference 4 The computer does not detect the USB device Please try the following 1 Check that the device is turned on If a blue light is not shining out of the microscope lens there is no power going through the instrument 2 Check that the computer meets the correct system requirements to use this instrument 3 If there is no window that says new removable device check the USB device 4 Try disconnecting the device rebooting the system and trying again 5 If you have connected the instrument to a USB hub please try connecting the microscope directly to the computer 6 Check that your USB port provides enough energy to power the unit If not try connecting it through a USB hub or if you have a y cable try connecting the instrument into two USB ports to provide more power 7 Check that the correct driver is installed in your control panel 8 Make sure that the USB device is connected to t
3. 1600 x 1200 1280 x 1024 64x 480 320 x 240 Colour 24bit RGB Lens Dual axis 27X amp 100X microscope lens Focus range Manual focus from 10mm to infinity Flicker frequency 50HzZ 60Hz Frame rate Max 30f s under 600 Lux brightness Magnification ratio 10X to 200X Shutter speed 1 sec to 1 1000 sec Video format AVI format White balance Auto Exposure Auto Light source 6 LED white lights adjustable light intensity PC interface Mini USB 2 0 with 1 2m cable Operating system Windows 2000 XP Vista Power supply 5V DC from USB port Size 110mm x 33mm Computer System Requirements e Microsoft Windows 2000 XP and Vista e Pentium 300 or AMD Athlon processor or higher e 100MB free hard disk space and 32MB or more of RAM e 16 bit colour display adaptor s e Available USB port p e CD ROM drive Software installation a oi S MA 1 Place the mini disc supplied with the g jo instrument into your CD DVD drive on your gy computer If a window called Digital g Microscope Application Setup Wizard jir a does not appear automatically please use Sl age the following instructions ES 2 Go to Start on your desktop s toolbar me and click on Run This will bring up a _ window that will allow you to search for the Ref operat98 instructions 15 37203 qxp 05 01 15 software you are trying to install Go to browse my computer and double click on D If this
4. Connection and Hardware Installation The hardware for this meter is installed at the same time as the software This means that as soon as the installation is complete for both programs the instrument and software are ready to use straight away Operation With your microscope connected to your PC open up the software called AMCAP and a window very similar to the webcam window will appear ja with a digital image of what the microscope is detecting Snapshot Function On the back of the microscope there is a raised button This is the snapshot button that allows you to take a still photo Using this application will not effect the instrument from normal operation as it opens a new window called SnapShot Reader Your still image will appear in this window and allow you to save or rotate the image through 180 Focus Function On the microscope there is a wheel that you can turn By turning this wheel you can control the focus of the images User Program To adjust options and take photos you do need AMCAP to be open at all times On the main window you will see a tool bar across the top see image below ean l LE File gt Set Capture File Lets you make an AVI File to store your photos taken using the microscope gt Allocate File Space You can choose how much memory you can spare on your computer to store your images gt Save Captured Video Choose where to save and store your v
5. is not showing in My Computer try removing the disc and starting again 3 In D there is an icon called pe Digital Microscope Seem te ie Ea era ami n a Application Installation es hae ee Double click on this icon to enter nna Digital Microscope Application Setup Wizard to install the software Make sure all applications other than the installation window are closed _ as this could affect the installation process 4 Follow the instructions on the Digital Microscope Application Setup Wizard Once this has finished this icon will appear on your desktop If not then the program will be found in all programs under the name digi view 5 To complete the installation another window Vimicro USB 2 0 UVC PC Camera InstallShield Wizard will appear At this point the microscope needs to be connected to your computer to aid the installation Follow the instructions 6 The installation should happen Meeme automatically but before installation is complete a window called Software Installation will appear with the following message opposite Please press Continue Anyway as it has been tested and is safe to use 7 Press Finish on the InstallShield Wizard and this icon el should appear on your desktop So you now have two different programs that can be used with this instrument 8 Close or minimise the InstallShield Wizard window
6. he same USB port used during the installation of the hardware 9 If this is still unsuccessful try uninstalling the hardware and installing again 10 Check that the USB port is still functioning correctly 11 Check that the USB port is activated in the BIOS Basic Input Output System of your computer 12 Deactivate the Legacy USB function in BIOS 13 If a USB device is not used for a while Windows will deactivate it Reconnect the device and try again 14 If Windows has a problem recognising the uSB port when your motherboard uses an AMD 754 chipset please install the Bus Master Drivers 5 Each time you connect the device using the USB port Windows tries to re install it again 1 Check that you re using the correct hard driver 2 Make sure that you are using the same USB port that you used when installing the hardware 3 Uninstall the hardware driver and try again 6 The file transfer is running low 1 Check that the USB port supports USB 2 You need the following service packs for USB 2 0 gt Windows XP Service pack 1 or higher gt Windows 2000 Service pack 4 or higher 2 Make sure that you just use one USB device at a time to transfer the files 3 Check that USB 2 0 is activated in the BIOS settings 7 The computer does not start any more or works very slowly The more USB devices you connect to your computer the more time it needs to start and load up Wait until the boot process is fi
7. ideo files gt Exit Closes the program Devices gt You can choose your preferred connection for your microscope You have an option between BERE copem Capture Hab jot mro USAR O LWC PE Camera w Sounda Cegtal Audio a Both of these will show you an image but one will be more focussed and clearer than the other The better one will vary with each computer Options gt Option allows you to decide if you would like to preview your photos within the program If preview is un selected there will be no image in the software window gt If you select any of the following Audio Capture Filter Video Capture Filter and Video Capture Pin it will open an options window from where you can adjust the settings to your preference Capture gt On the capture you can start and stop a capture gt Set a frame rate and time limit gt You can also select a master stream Help gt This option opens up a box to tell you the name copyright and serial of the program Operation Using Digi View Open up Digi View so the window that can be seen on the left hand side will appear on your desktop This software is easier to use but has a lot less functions options To take a photo press A Tss a jpeg file m oN 25 amp will appear underneath To take a video press fE vdeo Recond and a video will appear Across the bottom of the software window these icons can be seen d i
8. nished before you connect the USB device 8 You cannot transfer files on the USB device 1 Check that there is enough memory free on your USB device Delete files that you no longer need or transfer them to your computer to free up the memory 2 Re format the USB device with FAT32 please note that doing this will delete all saved files York Survey Supply Centre 2015

Download Pdf Manuals

image

Related Search

Related Contents

  Instruction Manual    Tech air Z0128  GE 29893 Telephone User Manual  SERVICE MANUAL - Manuals, Specs & Warranty  

Copyright © All rights reserved.