1. Germany Certificate number 88 162 11 HH Mark CE 0098 WF wwe Vu H Peters M Wenzel General Manager Proxy Holder Hofheim 28 May 2013 page 10 SEN 9601 K02 0513
2. GmbH Nordring 22 24 D 65719 Hofheim Tel 49 0 6192 2990 Fax 49 0 6192 23398 E Mail info de kobold com Internet www kobold com page 2 SEN 9601 K02 0513 SEN 9601 2 Note Please read these operating instructions before unpacking and putting the unit into operation Follow the instructions precisely as described herein The devices are only to be used maintained and serviced by persons familiar with these operating instructions and in accordance with local regulations applying to Health amp Safety and prevention of accidents When used in machines the measuring unit should be used only when the machines fulfil the EWG machine guidelines 3 Instrument Inspection Instruments are inspected before shipping and sent out in perfect condition Should damage to a device be visible we recommend a thorough inspection of the delivery packaging In case of damage please inform your parcel service forwarding agent immediately since they are responsible for damages during transit Scope of delivery The standard delivery includes e Pressure Sensor with Ceramic Instrument model SEN 9601 e Operating Instructions 4 Regulation Use Any use of the Pressure Sensor with Ceramic Sensor Element model SEN 9601 which exceeds the manufacturer s specification may invalidate its warranty Therefore any resulting damage is not the responsibility of the manufacturer The user assumes all risk for such usage Caution The manufa
3. KEN _ O Operating Instructions for Pressure Sensor with Ceramic Sensor Element Model SEN 9601 SEN 9601 We don t accept warranty and liability claims neither upon this publication nor in case of improper treatment of the described products The document may contain technical inaccuracies and typographical errors The content will be revised on a regular basis These changes will be implemented in later versions The described products can be improved and changed at any time without prior notice Copyright All rights reserved 1 Contents l 50 0 2 cane nn ann th oot A on A eee a ee eee CP eee ero e ew eee ane eee 2 2a uee nv SBT le aD ng A Eo OO I oe tee eee ee ee 3 Ss INSUUMENTINSDCCHON serranas anaa EA ETE AE 3 A REJUN USE sasra aa A sneaks 3 5 SI ic ee ce cre ic cee es cre er ee es a ata taal aetna ede haite thes 4 Gz Installat ren nausea needa 4 l Electrical Connection sesura EE tne E teeta te bacen EE EERE 5 Gs We 9 fa gl eea 6 9 Product AIDC aac cic adic sieves ove vies Sule i vec bos avie diss evicted nun od nde sob ve ney eatecauavoeeseueeoeeses 6 10 Technical Information cies tess sees te sera ies ere ie a ee eer ee ea ee eu ree eee ueiat 6 Wl OPOClGOOES cites ee eee eee 8 TZ 2 DIMENSIONS axceee ce oeecdsenveccesencectezcech EE 9 13 Declaration of Conformance ts cees ao coe aos hott Sos hots eos atts Se atts Sen ete Se ets Sel et te 10 Manufactured and sold by Kobold Messring
4. N 9601 K02 0513 SEN 9601 7 Electrical Connection 4 20 mA N of wires Charee Ohm UB 9V 6 02 Input UB I N E 2 J0 Vde 0 5 4 5 Vde eS E E Cha pe Ohm min SKohm ymin lOKohm min Kohm 5 EN 75301 803 Form A The transmitter metal case should always be connected to ground through the process connection thread in order to protect it from disturbances due to electromagnetic fields or electrostatic charges If it is not possible to do so connect the transmitter to ground through the connector and the cable screen SEN 9601 K02 0513 page 5 SEN 9601 8 10 page 6 Maintenance The SEN 9601 transmitter is maintenance free If a fault occurs contact Kobold Using transmitters that have been subjected to work not explicitly authorised by Kobold relieves the Company of any and all responsibility and causes the contractual guarantee to become null and void Product Label SEN 96010B075A0 8 30 VDC 0 10 bar 4 20mMA A lt 0 5 10 13 1 UB 2 0V OPC riri rr S 9 B0248 Technical Information Ranges Accuracy Non linearity BFSL Non repeatability Output signal deviation of zero Thermal drift Long term drift Process fluid temperature ambient and stocking temperature Output signals Response time Emission and immunity Process connection Sensor Case 0 1 0 600 bar relative 1 O 1 24 bar relative lt 1 0 of the r
5. PT clear text ee eae a ratiometric B085 0 16bar_ o U k 1 Aa A At 1 5 VDC 8 30 VDC Minimum or quantity 20 pieces per item identical model code Output signal 4 20 mA 0 5 Voc 0 10 Voc 0 5 4 5 VbDc 1 5 Voc code 0 1 2 ratiometric 3 4 No of wires Load max Q Ri lt Vin Ri gt 5 KQO R 2 10 KQ R 2 4 5KQ R 2 5 KQO 8 0 02 Voc Absorbed current lt 25 lt 10 lt 10 lt 10 lt 10 MA Mia a a a All output signals are provided of protection against short circuit and polarity inversion Insulation tension 500 Vpc page 8 SEN 9601 K02 0513 SEN 9601 12 Dimensions DIN 3852 E EN 837 B G t4 male EN 837 F 12 14 NPT G 18 NPT 0 Torque 20 30 Nm 5 For pressures up to 400 bar SEN 9601 K02 0513 page 9 SEN 9601 13 Declaration of Conformance We KOBOLD Messring GmbH Hofheim Ts Germany declare under our sole responsibility that the product Pressure Sensor with Ceramic Sensor Elements Model SEN 9601 to which this declaration relates is in conformity with the standards noted below DIN EN 61326 1 2006 Electrical equipment for measurement control and laboratory use EMC requirements Industrial environment Also the following EWG guidelines are fulfilled 2004 108 CE EMC Electromagnetic compatibility 2011 65 EC Restriction of Hazardous Substances RoHS 97 23 EC PED max 200 bar Category Module D1 D Notified body Germanischer Lloyd
6. ange lt 0 5 of the range according to EN 61298 2 lt 0 1 of the range according to EN 61298 2 lt 0 5 of span typical j 0 8 of span max Between 0 and 80 C 1 of span 2 5 of span Max lt 0 2 of span according to EN 61298 2 25 85 C 4 20 mA 0 5 VDC 0 10 VDC 1 5 VDC 0 5 4 5 ratiometric VDC lt 4 ms According to EN 61326 group 1 class B industrial applications In AISI 316L hole 2 5 mm Ceramic in Al203 In AISI 316L vented up to 16 bar SEN 9601 K02 0513 SEN 9601 Gasket Sensor FKM Electric connection EN 175301 803 Form A Protection degree IP 65 according to IEC 529 EN 60529 Weight 0 12 kg Including non linearity hysteresis non repeatability and output signal deviation of zero at the reference conditions described in standard EN 61298 1 with properly assembled electric connection Ranges Overpressure Bar relative Bar relative 0 4 E e 0 100 0 250 0 400 0 600 0 160 SEN 9601 K02 0513 page 7 SEN 9601 11 Order Codes Order Details Example SEN 9601 0 B075 A 0 Measuring range Mechanical Connection C 315 1 0 bar C 505 1 0 6 bar C 515 1 1 5 bar C 525 1 3 bar 0 4 20 mA C 535 1 5 bar A G male 2 wire standard standard B G male SEN 9601 1 0 5 Voc 0 without 8 30 Voc E GY DIN 2 0 10 VDC a ee neat F N
7. cal gases and water and oil designed to be installed in gas distribution plants on bottles on refrigerators on compressors on vacuum pumps and hydraulics and water high pressure plants It is ideally suited to be used in the industry in general in the gas stocking or machines production in light or heavy pneumatics industry in the refrigeration industry in welding and vacuum 6 Installation Before installing electrical instrument safely and securely into a plant or a system the user should verify the instrument suitability to the plant characteristics and the correct installation After installation the user should verify that the instrument is not exposed to any source of heat exceeding the established ambient limits Secure the instrument thread through a special key wrench on the process connection hexagon 20 30 Nm The correct torque depends on the type of process connection and the type of seal used form and material As for those process connections with a cylindrical thread Gas Metric a head gasket compatible with the measurement gas or fluid should be used If the connection thread is conical the instrument is tightened through a simple screwing on the plug In order to improve the thread tightness it is recommended to place a PTFE layer on the male thread If the instrument is equipped with a fluid diaphragm seal the connection should be clamped on the diaphragm otherwise the calibration could be compromised page 4 SE
8. cturer disclaims all responsibility in case of damages caused by the improper use of the product and by the non respect of the instructions reported in this manual Follow carefully the specific safety rules in case of measuring oxygen pressure acetylene inflammable or toxic gas or liquids Disconnect the instruments only after depressurization of the system The process fluids residuals in the disassembled instruments could affect people the environment and the system It is highly recommended to take proper precautions SEN 9601 K02 0513 page 3 SEN 9601 Before installation be sure that the right instrument has been selected following the working conditions and in particular the range the working temperature and the compatibility between the material used and the process fluid This manual does not concern the instruments conforming to standard 94 9 CE ATEX The product warranty is no longer valid in case of non authorized modifications and of wrong use of the product The user is totally responsible for the instrument installation and maintenance Handle and carefully stock the instrument used for toxic or inflammable liquids measurement The pressure transmitter turns the input pressure into an output electrical signal The electrical signal changes in proportion to the input pressure level 5 General The KOBOLD SEN 96 Standard model is an electronic transmitter with ceramic sensor for air industrial techni

Download Pdf Manuals

image

Related Search

Related Contents

Cambridge Audio Topaz AM10  電子レンジ用ゆで卵調理器具の使い方に注意!  テレスコピック クローラクレーン  GFIS Node User and Installation Manual  User manual  Máquinas Para Trabajar la Madera  ET-3200A ALICATE AMPERÍMETRO DIGITAL  全ページをダウンロード(PDF:1.2MB)  Toshiba Portégé R930 (3G)  ÉCRIVAIN PUBLIC - Pour entrer quand même sur le site, CLIQUEZ  