OPERATING INSTRUCTIONS PLEASE READ CAREFULLY

image

Contents

1. be left connected once charging has completed however disconnection within 12 16 hours is recommended for best performance Only the supplied charger should be used Operation 1 Connect your laptop or other network equipment to the DATA port using the supplied blue patch cable 2 Connect your IP camera or other PoE device to the POE OUT port using the supplied red patch cable 3 Switch on POINTSOURCE and allow the camera to power up 4 Configure the camera using the laptop as normal Note the laptop and camera are connected in exactly the same way as if they had been directly connected with a network crossover cable POINTSOURCE does not have any effect on the network data connection Therefore if you are experiencing problems connecting to the camera please consult the camera manufacturer s documentation or contact your camera supplier for support You can leave POINTSOURCE switched on and hot plug network connections without damage however it is recommended to switch off the unit when not in use even if it is fully discharged Technical specification 190 x 120 x90mm 7 5 x4 7 x3 5in 1 7kg 3 75Ib unpackaged RoHS Battery Directive compliant CE FCC REACH exempt IATA non restricted OK to transport by air Operating 20 to 45 C 4 to 113 F Charge 0 to 35 C 32 to 95 F Network 100BASE TX 10BASE T PoE IEEE 802 3af 15 4 watts max Dimensions Weight Compliance Temperature Auxilia
2. POIN I SOURCE BATTERY POWERED POE INJECTOR OPERATING INSTRUCTIONS PLEASE READ CAREFULLY Package contents 1 x POINTSOURCE unit 1 x Shoulder strap 1 x Universal charger UK US EU AU plugs 1 x 1 5m Red network patch cable 1 x 1 5m Blue network patch cable 1 x Operating instructions this leaflet Important safety notes gt Only the supplied charger should be connected to POINTSOURCE gt Donot charge POINTSOURCE in a fully sealed enclosure gt Donot attempt to service the unit or replace the battery Other brands of lead acid battery are not compatible with POINTSOURCE Take care when connecting accessories to the 12 volt terminals POINTSOURCE can deliver high currents before tripping its internal fuse Maintaining battery performance For optimal battery performance and longevity POINTSOURCE should be fully charged e before first use after long periods of storage e before being stored for long periods every six months during storage Always switch off POINTSOURCE when it is not in use even if the unit is fully discharged Disconnection from the charger within 16 hours is recommended veracity Overview Veracity s POINTSOURCE is a portable rechargeable battery powered Power over Ethernet PoE injector Itis designed to be compact and easy to handle yet able to deliver enough power to support a full day of IP camera installation POINTSOURCE can be used with all PoE pow
3. ed by a single 3 amp self resetting fuse however note that the auxiliary output can deliver significant currents for short periods before the fuse trips Battery replacement and end of life POINTSOURCE has an anticipated battery life of 3 5 years or approximately 200 1000 charging cycles depending on discharge depth and operating temperature It uses a maintenance free Sealed Lead Acid battery that is not replaceable by the user however a battery replacement service may be available contact Veracity for details Only Veracity specification batteries may be used in POINTSOURCE other similar sized units eg Yuasa are not compatible Where the product has been purchased within the European Union it should be disposed of at a lead acid battery collection facility or returned at the customer s expense to Veracity UK Ltd A professional service engineer may remove the battery for disposal by unscrewing the case and detaching the battery terminals Also from Veracity HIGHWIRE HIGHWIRE Ethernet over Coax technology lets you upgrade analog installations to digital easily by re using up to 300 metres of RG59 cable as a full JOOBASE T network connection OUTREACH Simply connect an OUTREACH Max to double the 100 metre range of Ethernet and PoE over Cat 5 or use multiple units to extend network and power up to 800 metres TIMENET Synchronising your DVR NVR installation to an accurate reference time is essential TIMENET recei
4. ered equipment such as IP cameras and wireless access points enabling applications such as e on site configuration site surveys and pre installation trials customer demonstrations mobile and temporary installations It complies with the universal 802 3af PoE standard and can deliver up to 15 4 watts of PoE power while simultaneously powering other 12 Volt accessories if required Network crossover between ports is integrated to allow direct connection of a laptop PC as shown in the example below POINTSOURCE lt gt P CAMERA gt POE POWER LAPTOP OR PDA lt gt NETWORK DATA Connections To 12V accessories Power switch PoE status OFF CHARGE ON Enabled ON FLASH Error OFF No PoE Battery level FULL HALF To Laptop To Camera LOW Charging POINTSOURCE should be charged before first use and after long periods of storage f stored it should be fully charged before storage and recharged every 6 months to maintain battery performance To charge the POINTSOURCE unit connect the supplied charger to the socket on the side of the unit with the unit switched off The unit should sit on a horizontal surface in a ventilated area such as a shelf or bench in an office or workshop during charging The LED on the charger will light red during charging and green when charging is complete or if no charge is required Charge time is typically 4 8 hours The charger can
5. ry output 10 to 13 5 volt Typ 12 volt 1 5 amps max Fuse 3A slow blow self resetting Discharge life 6 hours continuous fora 5 watt camera typ Charger Three stage intelligent POINTSOURCE is designed for indoor use only For outdoor use suitable weather protection must be employed If the product is dropped or sustains physical damage discontinue use immediately and dispose of the product safely LED indicators The three green LEDs provide an indication of remaining battery life though the level may dip under heavy load If only one LED lights recharging is recommended If none of the battery LEDs light then the battery is fully discharged and the unit will not operate to prevent battery damage In this case leave POINTSOURCE switched off until it has been charged The red LED lights when power is being delivered to a compatible device connected to the DATA port It will flash if an incompatible non 802 3af device has been connected or if the device has drawn more power than it is permitted to Using the 12 volt output The 12 volt output can be used for accessories such as monitors or meters and may be used at the same time or independently of the PoE supply Before connecting any equipment switch off POINTSOURCE check the wiring polarity and ensure that the equipment can accept power in the range 10 to 14 volts The current drawn should not exceed 1 5 amps The PoE and auxiliary outputs are both protect
6. ves atomic time from GPS and hosts it as a universal NTP server WWW VERACITYGLOBAL COM