1. d will be displayed Key in the zone num ber s to be omitted which will flash to confirm selection Zone indicators which show steady are still about to armed When the selection is com plete press Set and the exit tone will sfart if a zone refuses to be omitted it may be because the engineer has programmed the con tro system to prevent you from turning off the zone ff in doubt ask for advice QUICK SET During the exit period after entering your code the system may be Set quickly by pressing Sef This removes the time period usually allowed for exit and would be used if you are not leaving the premises If you omit zones and require Quick Set you will need to press Set twice CHIME Chime is a low security monitoring system for use when the system is Unset When a zone that is set to chime is operated the internal sounder will produce a low volume two stage warning tone and the Zone indicator will show The indicator may be cancelled by pressing Reset Chime is particularly useful in a shop to warn of a customers presence or in a house to warn that a door or a particular area has been accessed Any zone may set to be on or off chime by press ing the CHIME key and then keying in the required zone number s Key 0 to cancel all zones from chime After a few seconds the sys tem will automatically return to the Day mode POWER INDICATOR The red Power indicator on the control panel or RKPs should be showing at all
2. intruder Alarm Control System Operating Instructions nee coer 2 As fe Sass SP no CL lt ff e SS a S Se es 000000 moj OOOOH 8 OOOOG 50000 gt 6 zones plus PA and Tamper p gt On Board Backlit Keypad gt Option of up to four remote keypads per installation gt Three fully selectable part set programs gt Chime on any zone gt 8 event memory recall indicates first and subse quent alarm activations B gt Programmable timers including bell cut off gt NVM for protection of engineer programme gt Quick set feature gt Service warning indicator programmable between 200 and 1200 Set and Unset events Operating Information CE Intruder Alarm Control System Operating Insiructions The Optima Compact Optima is a highly flexible intruder alarm control system designed to be in stalled in a wide variety of applications Up to three progroms may be preset within Optima Compact Optima to allow full control over selected areas of your property The Engineer Details section of these instructions contains a chart showing the zones in each Program For Clarity the information below on Setting the System assumes that all Programs use a Timed or Final Door Setting routine TO SET THE SYSTEM ON PROGRAM 1 The green Day indicator should be showing Enter your code number and check that the sys tem is clear none of the Zone indicat
3. now in the memory To stop the memory recall Press Day indicator shows or wait for the scrolling to y stop automatically Adding Deleting Changing User Code 2 Day indicator shows User code 1 generally considered as the system managers can add delete or change user code Notes 2 1 if the Day indicator shows in any of the alarm events that alarm condition occured Follow the information above but use Key 7 instead in the Day mode of 8 to change user code 2 To delete the code press Omit instead of entering a new code 2 Ifthe alarm event shows as a blank display then that event is empty Engineer Details Alarm Company Name Press PROG All indicators will show Enter your code Tamper indicator shows Tamper and press _ O Attack indicators show The system is now in the test routine Press 1 To Test Set Output Press O to stop Account No i TETTETETT FE GOES OF50 OFFS F500 FOF 9F FEES HESS ETE HOD OF SSO OH SEE HOC SOCOE Date of Installation kha a ESOS EEDEF SSE DHSSS OESSCHSSSHESESESS SS ESHOSSSSH SERFS SACOG SHE SFHHOESCESSSOHOHSSH HEH ESSS EES ESSCOEED Area Protected Pro 3 2 D Ni e 3 D N To test the strobe Q NINjN lololo J121313 DID IDO Of Ou BE Oo To test the external bell sounder To test low volume internal sounder To test high volume internal sounder To ente
4. ors are showing The sounder will now produce an exit beep tone and you should leave by the approved route The system will Set as the tone stops TO SET A PROGRAM The green Day indicator should be showing Enter your code number and the exit tone will start Press the Prog key and the exit tone will stop Press 1 2 or 3 for the required program the sounder will beep to acknowledge the program number The exit tone will start and you should leave by the approved route The system will Set as the tone stops it is important that you follow the correct pro cedure when setting the system After leaving the protected area it is absolutely essential that you wait until the exit tone stops before assuming the system has Set FAULTS DURING SETTING if the system is not clear when you try to Set it the sounder will produce an open zone tone and the fault will be displayed Either re enter your code to turn off and investigate or omit the faulty zone s from the system TO UNSET THE SYSTEM Turn Off Enter your code If the system has not been pre viously activated the green Day indicator will come on If the system has been activated then entering the code will turn the alarm off and the cause of the alarm will be displayed Press Reset to clear the indication TO OMIT A ZONE During the exit period after entering your code and selecting a program press OMIT the exit tone will stop and the zones that are about to be arme
5. r walk test During Pross 5 walk test the intemal sounder wil beep and the respective Zone Press Co to StOP indicator will show as each circuit is tested Press Day indicator shows CHLORIDE SAFETY SYSTEMS Due to continuous product development ADE reserve the right to change emeemess FEJBSIA T3198 98
6. times If the indica tor goes off the mains supply has failed or been disconnected If in doubt consult the Engineer FAULTS PROBLEMS if any faults occur or if any fault indicators remain on contact the Engineer for assistance SEVICE MAINTENANCE It is important that you fully understand the oper ation of your alarm system and that it is regularly serviced and tested by the Engineer if the Tamper indicator starts to flash this means that your system may require servicing It will not prevent the system from being used but you should call the engineer for advice To test your alarm system change your code or recall the alarm memory follow the instructions below Before you begin check that the Day and Power indicators are showing and that they show again when you have finished programming or testing ALARM MEMORY RECALL Press PROG All indicators will Press PROG A indicators will show Enter your code C7JC 7IC IjC73 Enter your code Tamper indicator shows CL L 2 Ce Press The indicators will now scroll to show the last 8 Tamper indicators show alarm conditions The sounder will bleep as each new condition is shown Zone indicators Pross 1 2 3 and 4 show Now enter your new code 4 digits To view the previous event To view the last newest event To view the oldest event A series rapid blips will be heard and the Tamper To continue scrolling indicator will show events The new code is
Download Pdf Manuals
Related Search
Related Contents
Butterfly Valves - Chemline Plastics Limited C-more Micro-Graphic Hardware User Manual Dataflex LTX Laser Printer Hood Stand 290 Panasonic Air Conditioner 取扱説明書 eBuy User Guide Soil Classification Soil Equipment Bedienungsanleitung MIKRO Professional 4 Kaltura`s Entitlement Infrastructure Information Copyright © All rights reserved.