Operating Instructions Omega 5 Control Panel

image

Contents

1. figure code and display flashing E 3 1 Bell Test 3 2 Walk Test Cattle Carcieah Ltd Omega s Alarm System Operating Manual 3 3 Alarm Memory L With the Control in the test mode display E press 2 followed by enter The memory is now accessed 2 The display will show the number of the keyholder I or 2 who armed the system _ followed by the zone that caused the alarm press scroll e to display any further zones to alarm press scroll to display omitted zon es and the keyholder who disarmed the system and finally three bar s end of event next event will begin press enter to return to the day mode 3 4 Changing Your Access Code The Omega 5 has 2 customer codes NB Any code that reads identically forwards and backwards will not be Following the bell test you can perform a walk test 2 Alternatively with the H displayed key in S and press enter 4 zones in fault will be displayed and sounder tone changes 3 When you are satisfied with the test press enter to return the Control to the day mode accepted 0 will be displayed re enter a different valid code press ENTER to return to the DAY mode For example Acceptable Code 1234 Unacceptable Code 1221 The reverse of Code I is NOT acceptable as Code 2 Do NOT use codes beginning with number 0 With the Panel in the test mode key in 4 and press enter display n 4 Key in the number of the k
2. Castle Care Tah Ltd Omega s Alarm System Operating Manual Cattle Cam7ah l td Omega S Alum System Operating Manual 6 Sounds and Indications 6 1 Sounder Tones Mode Tone Exit Soft Continuous Tone Fault on Exit Soft Interrupted Tone Entry Mode Soft Pulsing Pips Walk Test Soft Pulsing Pips Keypad Entry Soft Single Pip Operator Error Loud Single Tone Alarm Loud Sweeping Tone Chime Bing Bong 3 to silence Tamper Loud sweeping tone All tones except clume may be silenced by entering the 4 digit code and enter 6 2 Omeea 5 Indications Operating Instructions Omega 5 Control Panel A Flashing Code required to enter customer test mode DAY mode d flashing Panel requires engineer to reset the system Communicator Line Fault Mains Fail F flashing Low volts or bell control tamper 0 9 Zone Alarm 0 9 flashing Zone Tamper Alarm Flashing Part Guard Armed steady Full Guard Armed Duress Alarm or Keypad Code Guessing Walk Test mode W 3 Page 8 Contents Arming LI Full Guard 1 2 Part Guard 1 3 Fault Warning During Exit 1 4 Omitting Zones 2 Entry 21 Disarming the System 2 2 Cancelling an Alarm 2 3 Resetting the System Test Modes 11 Bell Test 32 Walk Test 33 Alarm Memory 34 Changing your Access Code 4 Warnings 4 1 Tamper blamings 4 2 Monitor Warnings 4 3 Resetting a Warning 5 Special Operations 5 1 Silent Set 5 2 Auxiliary Output 5 3 Monitor 54 Using the
3. Omega 5 with Remote Keypads b Sounds and Indications 6 1 Sounder Tones 6 2 Omega 5 Indications NOTE Castle Care Tech Ltd reserve the right to change the specification of this system at my ume in the interests of product improvement In S Paget Castle Care Tech Ltd Omega 5 Alarm System Operating Manual Arming 1 1 Full Guard I Key in first two digits of your code and press enter or turn the key to FULL ON _ The indication will briefly Flash 8 as a lamp test then continuous exit tone sounds 2 Now leave by the exit route _ exit tone stops followed by a pip _ alarm now set 1 2 Part Guard L Key in first three digits of your code and press enter or turn the key to PART ON The indication will briefly flash 8 as a lamp test then scroll any zones automatically omitted followed by continuous exit tone sounding 2 Exit tone stops followed by a pip system set 1 3 Fault Warning During Exit If during exit the sounder tone is NOT continuous then the Panel will display the zone in fault EITHER clear the fault close the door etc OR omit the zone by pressing the zone number and enter the omitted zone number will flash briefly to confirm omission Do NOT exit with the Panel in fault condition as the system is NOT set 1 4 Omitting Zones To isolate a part of the alarm system after switching the panel ON just key in the zone number and press enter k the zone number will flash brief
4. ated _ sound and indication If the zone wiring is broken or a detector is tampered with a tamper alarm will occur and the zone number will indicate when the alarm is cancelled warnings with four digit code and press enter 4 4 2 Monitor Warnin s Mains failure display F Telecom line failure display L 4 3 Resetting a Monitor Warninp Key in 3 and press enter to cancel alarm tone 2 Key in your four figure code to return to the day mode Page 6 Castle CareTec6 Ltd Omega 5 Alarm System Openting Manual 2 Entry 2 1 pisarmingthe System Enter by the entry route entry tone sounds 2 Go direct to Control Panel key in your four figure code and press enter or turn the key to OFF REMEMBER if you arm with the key you can ONLY disarm with the key If you arm with the keypad you can ONLY disarm with the keypad 3 System now off display d day mode 4 If entry time is exceeded or you deviate from the entry route the alarm Reset tamper will sound 2 2 Cancelling an Alarm Key in your four figure code and press enter display shows zone that caused the alarm 2 3 Resetting the System Key in your four figure code and press enter 9 display d Page 3 Castle Care Tech Ltd Omegas Alarm System Operating Manual 3 Test Modes Ensure the system is in the day mode display V 2 Key in 1 and press enter display flashing A 3 Enter your master four
5. eyholder whose code is to be changed ie I or 2 2 display E 3 Now key in your new four figure code and press enter 9 display n To change code 2 key in 2 and press enter and key in the new four figure cod e and press enter Press enter twice to return the panel to the day mode
6. ly to confirm ontission W S Page i Castle GroTech Ltd Omega 5 Alarm System Operating Manual 5 Special Operations 5 1 Silent Set To arm the system without any tone sounding press the key instead of enter after keying in the first two digits oFyour code WARNING The system is only set when the final pip is heard Be careful not to leave the system with e aull present 5 2 Auxiliary Output If you are using the auxiliary output for say water leak detection freezer failure external lighting etc the output may be reset by keying in your four digit code and enter 5 3 Monitor If you have any zones designated as monitor zones then in day mode the sounder will chime if these zones are violated To turn off the monitor chime in day mode press 3 and enter d zones violated will then only indicate 5 4 Usine the OmeQa 5 with Remote Keypads RDTs All the operational facilities are identical on the remote keypads as described here EXCEPT that the OMEGA 5 log review is seen by keying in 0219 in day mode IM 3 Page 7 Castle CaroTech Ltd Omega 5 Alarm System Operating Manual 4 Warnings 4 1 Tamper WarninCS If the 12 volt intemal supply system should reach a critically low level a tamper alarm continuous internal sounder will be generated and the display will indicate the appropriate warning If the supply to the external audibles should fail or be tampered with a tamper alarm will be gener

Download Pdf Manuals

image

Related Search

Related Contents

Philips HD3133/00  MANUAL DO CONSUMIDOR - Amazon Web Services  datasheet: pdf  Farm & Ranch FR1245-2 Instructions / Assembly  Rat Glial Precursor Cells - Thermo Fisher Scientific  取扱説明書 - 第一電波工業    「Linux 環境に対応したHP Serviceguard」(PDF: 2.11MB)  Pelco FR8316 Satellite Radio User Manual  Alcatel OmniPCXOffice Alcatel 4018/4019  