Home
Wood Burning Inset Stove Installation and Operating Instructions
Contents
1. Di USSO Wood Burning Inset Stove Installation and Operating Instructions JINDLUO5 Rev D 14 11 14 Di Lusso CE R5 Di Lusso Emperor Way Exeter Business Park Exeter United Kingdom EX1 3QS Recommended Fuel Wood Important Use Only Recommended Fuel Follow the Operating Instructions DSEN13229 Inset Wood Burning Stove 79 4 9 kW 0 2 Mean Flue Gas Temperature 239 C Flue Gas Mass Flow 5 4 g sec NS3058 59 This appliance is not suitable for use in a shared flue This appliance is suitable for intermittent burning Smoke Control Areas This appliance is only exempt for use in a smoke control area when fitted with a smoke control area kit JDLUO501 Find out if you are in a Smoke Control Area by contacting your Local Authority Contents General Guidance Appliance Dimensions Flue Requirements Preparing the stove for installation Direct Air Adaptor and Convection Duct kits Installation into a solid non combustible wall Hearth requirements Clearances to combustibles Fitting the stove Flue Connection Installation into a non combustible enclosure Enclosure Dimensions Re assembling the stove Fitting the Frame Pack Commissioning Operating Instructions Recommended Fuel Air Controls Lighting Recommended Settings Refueling De ashing Maintenance Troubleshooting Spares Page 1 Page 3 Page 3 Page 4 Pages 6 amp 10 Page 6 Page 7 Page 7 Page 8 Page
2. Door Catch Over time the rope seal in the door will become compressed It may therefore be necessary to adjust the door catch to maintain the door seal To adjust the catch slacken the two set screws on the catch bar and adjust the position of the catch bar as necessary Air Valves Over time the sealing face of the air valves may wear This will reduce the 17 effectiveness of the controls To replace a worn valve remove the air valve cassette lift off the worn valve and replace with new Trouble shooting Fire will not burn Check that e The air inlet slots in the front of the stove are not obstructed in any way e Chimneys and flueways are clear e 6A suitable fuel is being used e There is an adequate air supply into the room e Anextractor fan is not fitted in the Same room as the stove e Flue draught is above minimum level see installation instructions Fire blazing out of control Check that e The door is tightly closed e The air controls are in the closed position e A suitable fuel is being used e The glass is not loose e The door rope seal is in good condition e The air valve sealing faces are not worn e Flue draught is below maximum level see installation instructions LEO SOJWH loulpjey Bon 4 ZO LIA V FOJWH LAR joo Buibliado N AN Z0OO LJJV SOJWH 94019 SNOW ma r ao W AY T Sl GSO SOJWH 1919 2114 IDSY Su
3. The supplied operating tool or gloves may be used to open the door and operate the air controls AEROSOLS Do not use an aerosol spray on or near the stove when it is alight FIRES CAN BE DANGEROUS Always use a fireguard in the presence of children the elderly or the infirm The fireguard should be manufactured in accordance with BS8423 Fireguards for use with solid fuel appliances DO NOT OVER FIRE it is possible to fire the stove beyond its design capacity This could damage the stove so watch for signs of over firing If any part of the stove starts to glow red the stove is in an over fire situation and the controls should be adjusted accordingly Never leave the stove unattended for long periods without first adjusting the controls to a safe setting Careful air supply control should be exercised at all times FUME EMISSION properly installed and operated this appliance will not emit fumes Occasional fumes from de ashing and refueling may occur Persistent fume emission must not be tolerated This appliance should not be operated with the door open If fume emission does persist then the following action should be taken immediately e Open doors and windows to ventilate room e Let the fire out or eject and safely dispose of fuel from the appliance e Check for flue chimney blockage and clean if required e Do not attempt to relight the fire until the cause has been identified and corrected e
4. f necessary seek professional advice ADVERSE WEATHER In a small number of installations occasional local weather conditions e g wind from a particular direction may cause downdraught in the flue and the stove to emit fumes In these circumstances the stove should not be used A professional flue installer will be able to advise on solutions to this problem e g anti downdraught cowl EXTRACTOR FANS DO NOT FIT AN EXTRACTOR FAN IN THE SAME ROOM AS THIS APPLIANCE IN THE EVENT OF A CHIMNEY FIRE e Raise the alarm e Call the Fire Brigade e Close appliance air controls e Move furniture ornaments etc away e Place a fireguard in front of stove e Check the chimney breast for signs of excessive heat If the wall is becoming excessively hot move furniture away Ensure the Fire Brigade can gain access to your roof space in order to check for fire spread 750 APPLIANCE DIMENSIONS 662 355 FLUE OUTLET POSITION The flue outlet angle and position is determined by the orientation of the flue collar The outlet can be either vertical or leant backwards by 30 To change the angle rotate the flue collar by 180 The effective centre dimensions in millimeters are shown below FLUE REQUIREMENTS The flue serving this appliance must be dry free from cracks and obstructions and be in accordance with the designations shown in Table 1 The diameter of the flue should not be less than 150mm a
5. 8 Page 9 Page 11 Page 12 Page 12 Page 13 Page 13 Page 14 Page 14 Page 15 Page 15 Page 15 Page 16 Page 16 Page 17 Pages 18 20 Guarantee The body of the stove is covered under a five year guarantee from date of purchase to be free from defects in materials and workmanship Internal components other than consumable items such as glass and firebricks are covered for a period of one year from date of purchase General Guidance It is important that your stove is correctly installed as Di Lusso cannot accept responsibility for any fault arising through incorrect use or installation These instructions cover the basic principles to ensure satisfactory installation of the stove although detail may need slight modification to suit particular local site conditions The installation must comply with current Building Regulations national and European standards Local Authority byelaws and other specifications or regulations as they affect the installation of the stove The Building Regulations requirements may also be met by adopting the relevant recommendations in the current issues of British Standards BS 8303 and BS EN 15287 1 COMPETENT PERSONS SCHEME Di Lusso recommend that this stove is installed by a member of an accredited competent persons scheme e g HETAS If the installer is not a member of a competent persons scheme it is a legal requirement in the UK to notify your local building control body in advance
6. D a E SCALE I 10 7e o a TOM o a ni Pm 300 N B Ventilation openings are identical SECON BER on both sides of the enclosure 11 RE ASSEMBLING THE STOVE 1 Smear some fire cement around the flue outlet on the outside of the Fire cement firebox 2 Offer the firebox into position and push it as far back as possible 3 Refit the fixing screws through the firebox legs Tighten the screws equally to draw the firebox into place Do not over tighten 4 Refit the two M8 x 25mm studs into the two fixing holes around the flue outlet Fix in place with the washers and nuts 5 Wipe off any excess fire cement around the inside of the flue which may have been squeezed out when fitting the firebox 6 Refit the fire bricks grate support ash pan log retainer and baffle 7 Check that the valves are in the fully open position fully clockwise and refit the Air Valve Cassette 8 Close the stove door and check that the touch latch pin is in line with the touch latch in the control fascia 12 FITTING THE FRAME PACK 1 Loosen the four M6 Nuts to the ends of the studs on the convection chamber sides 2 Slide the frame into position making sure that the lower inner edge of the frame is in line with the base of the stove and tighten the nuts with a 10mm spanner 3 Place around spacer supplied with the frame pack over each of the fascia studs 4
7. Offer the door fascia into position passing the three M6 studs through the holes Ensure that the fascia is resting on the two clips at the top Operating Instructions Read the General Guidance Section at the of the door and fix in position using the nuts and washers provided Close the door and check that there is an even gap between the frame and door fascia on the left and right hand sides approximately 16mm Adjust as Necessary COMMISSIONING Upon completion of the installation allow a suitable period of time for any fire cement and mortar to dry out A small fire may then be lit and the installation checked to ensure the smoke and fumes are drawn up the flue and emitted safely to atmosphere The stove should not be run at full output for at least 24 hours Read the Operating Instructions before lighting the stove for the first time 13 start of these instructions before operating your stove for the first time IMPORTANT Do not hang pictures televisions or combustible ornaments above the stove as these could be damaged and could potentially create a fire hazard For more information read the Clearances to Combustible Materials section of the installation instructions on page 7 WARNING This appliance will be hot when in operation and due care should be taken The supplied operating tool or gloves may be used to open the door and operate the air controls THE CLEAN AIR ACT 1993 AND SMOKE CON
8. TROL AREAS Under the Clean Air Act 1993 local authorities may declare the whole or part of the district of the authority to be a smoke control area It is an offence to emit smoke from a chimney of a building from a furnace or from any fixed boiler if located in a designated smoke control area It is also an offence to acquire an unauthorized fuel for use within a smoke control area unless it is used in an exempt appliance exempted from the controls which generally apply in the smoke control area The Secretary of State for Environment Food and Rural Affairs has powers under the Act to authorize smokeless fuels or exempt appliances for use in smoke control areas in England In Scotland and Wales this power rests with Ministers in the devolved administrations for those countries Separate legislation the Clean Air Northern Ireland Order 1981 applies in Northern Ireland Therefore it is a requirement that fuels burnt or obtained for use in smoke control areas have been authorized in Regulations and that appliances used to burn solid fuel in those areas other than authorized fuels have been exempted by an Order made and signed by the Secretary of State or Minister in the devolved administrations Further information on the requirements of the Clean Air Act can be found here http smokecontrol defra gov uk Your local authority is responsible for implementing the Clean Air Act 1993 including designation and supe
9. ating tool or gloves should be used to operate the air controls RECOMMENDED SETTINGS Once the fire is established the Ignition Air Control should be fully closed and the Combustion Air Control turned to a setting of approximately 20 30 open This setting should allow the nominal output and efficiency to be achieved Avoid running the stove on very low air settings as this could result in a reduction in efficiency and increase emissions into the atmosphere REFUELLING Avoid refueling on to a low firebed as this may cause excessive smoke emission Ensure there are sufficient embers to ignite the new fuel load rapidly Alternatively add some more kindling before adding larger pieces of firewood Do not add firewood above the level of the tertiary air inlet at the back of the stove Exceeding this amount can result in the production of excessive smoke DE ASHING To remove the ash pan for emptying insert the end of the operating tool into the socket on the ash pan and withdraw it from the grate Do not allow ash to build up to the level of the grate Maintenance Important In order to ensure continued compliance with current Building Regulations Local Authority Byelaws and the Clean Air Act if applicable this appliance requires regular maintenance of the following COMPONENT REMOVAL Baffle Brick Lift the baffle and slide it to the right or left to free it from the side bricks before lowering it into
10. efore deciding on this method Flue Liner Suitable For Solid Fuel Flue Liner Adaptor A ES If connecting to an existing masonry chimney it is recommended that a flue forming pipe short length of flue pipe is used and the void between the flue forming pipe and the chimney is filled with vermiculite concrete A suitable access hole will need to be made in the chimney breast to allow the back filling to be carried out and then filled and sealed once the installation is complete Alternatively a connection can be made using a register plate although it will be necessary to allow access for fitting the flue pipe to the register plate and sealing all joints Vermiculite Concrete Flue Forming Pipe Register Plate Connecting Flue Pipe i Ze fi INSTALLATION INTO A NON COMBUSTIBLE ENCLOSURE The Di Lusso R5 has been designed tested and approved to be installed either into solid non combustible material or into an enclosure according to the following specification It is the duty of the installer to ensure that the requirements of this specification and all relevant standards are met e There must be no combustible material within the construction of the enclosure e The stove should be supported on the Di Lusso Enclosure Stand Part Number HMROS5ARRTO13 e The enclosure must be produced from 30mm Skamol Super Isol board held together with a non combustible framework and finished i
11. en LERN iR AT LyO SOAWH ISAOD AIDIS PUNOdWIOD Z O SOUWH 109 AW UONIUBI SO SOJWH 19119 314 1D9Y ddn eee nn aS AA A JOSO SOJWH DUDH IUDI YOSO SOJWH DUDH HS7 APU 3114 SPIS PSO SOJWH ACU 911404 f pi d 2 F iy e v AF V f Pii f F d E Pa H Sen w s 4 4 A x P e L a e F li ras a soJeds Apog 18 790 FONWH _ SO0 LISW SOIWH 3009 YO OU JLIJWOD ud 45407 YONo 2 090 SOJWH OLO LYNV SONWH woog dijH 198LDAS SO Ajquessy UDJDD JOOG L 90 SOJWH 3pIS diy 19S9DAS SSO O L00 SON10 SD 9 JOO S Sdoy 1000 ZS0 VOAWH 190 g SOUH san 50 bolqi4 PS UN NO leddn di ER EE SZO SONWH b Aa aili AJquuassy sissoyp 100 19 saJeds 100q Yo61 ONS 900 NNW GOJWH 8PODJ SHESI MIDA Jiy OPPAD OD0 SOJWH AJQquISssy DIDDY JUOD LEO FONWNH qouy oUon OSO POJWH S10 4 YOUONUISYI SA ZZO LIY POSWH SI UISSsy pouysnd L gt ZO lJlav rOJWH AIQuuessy 2019 PEYI A MI DOD SY AOOHDIS 6 0 SOSWH S10 4 JUOIY SLLSSSDI SAPA Aly YS00 I v rOJWH IquIassy AUOD 1189 PUPH 4YBI 1600 13 v POYWH YOZO LIIY POYWH AJquusssy UbIO 199 PUDH 4J97 AQUISSsY SAPA My PUDH UB N SLO SOYWH SWD SLLOSIOTD SAPA Aly ZO POJWH SIPUIAS SADA Aly 10Z0 l l v PONWH AIQUISSSy SAPA Iy PUOH H97 S9Jeds 9119558 anjenA AY 0 N
12. indow or Within At least 600mm above any part 2300mm of ofthe adjacent building within an adjoining 2300mm or adjacent O building whether or not beyond the boundary Table 2 Flue terminal positions N B When closing the door keep the door handle out to the right until the door is closed 2 Remove the nuts washers and M8 x 25mm studs located either side of the flue outlet Q O 5 Carefully slide the firebox out from 3 Remove the Air Valve Cassette by removing o DO the convection chamber remove any the two fixing screws holding it in place ein put ihe Trebor and Air turning both air controls fully clockwise and vale cassete nasa pae These gently pulling on the fascia to slide the BAFSAVI AGE beheaded aeainuntl cassette out from under the firebox N B DO NOT remove the Air Valve Cassette with the controls in the closed position as this will damage the valve gaskets the final stages of the installation 4 Remove the two fixing screws located on the firebox legs IMPORTANT This appliance may be installed either into a solid non combustible opening or into an enclosure fabricated from non combustible sheet material as per the specifications in these instructions For installation instructions covering the approved enclosure design please proceed to page 9 DIRECT AIR ADAPTOR AND CONVECTION DUCT KITS If fitting either the Direct Air Adaptor Kit or Convectio
13. ld be provided The constructional hearth should be made of solid non combustible material and can include any solid non combustible floor The boundary of the hearth must be 300 or Over clearly marked This can be done by adding a super imposed hearth on top of the constructional hearth e g a slate slab on top of a solid concrete floor Appliances installed with the base plate Est Magi lower than 300mm above the hearth should have a constructional hearth extending to at least 650mm in front of the stove and 150mm at the sides CLEARANCES TO COMBUSTIBLE MATERIALS There should be no combustible materials for a distance of 450mm either side of the stove or 750mm above No combustible furniture should be placed any closer than 1100mm from the front of the stove Allow sufficient clearance between the stove and pictures electrical equipment or ornaments etc as these could be damaged and could potentially create a fire hazard 750 rai Appliances installed with their base plate 300mm or more above the hearth require a be kept clear of combustible material This area must constructional hearth with a depth of 225mm in front of the stove The base on which the This area must be kept clear of stove is mounted should be an extension of combustible furniture the constructional hearth i e all material between the stove base and the constructional hearth must be solid non combustible
14. m a draught stabilizer must be fitted so that the rate of burning can be controlled UY and to prevent over firing If the reading is less than the recommended minimum then the performance of the appliance will be compromised The flue draught should be checked under fire at high output Minimum Draught 1 2mm Water Gauge Maximum Draught 2 5mm Water Gauge Terminal Clearances to Flue Outlet PREPARING THE STOVE FOR INSTALLATION At or within At least 600mm above the ridge The firebox must be separated from the 600mm of the ridge outer convection chamber prior to fitting the Bien eter tease cana ONAY stove This allows easier handling of the on aroof from the nearest point on the whether weather surface and stove and protects the internal firebox from pitched or flat a Atleast 1000mm above the highest point of also recommended that the loose internal intersection of the A chimney arid the weather components Ash pan grate fire bricks damage during the installation process It is Surface or baffle and log retainer within the firebox are At least as high as the ridge Below ona At least 1000mm above the top removed pitched of the opening roof or within 1 To open the stove door press on the 2300mm horizontally door handle to release it from the latch Swing the door handle out to openable rooflight the right until the mechanism engages GO men and the door catch is released w
15. material FITTING THE STOVE IMPORTANT Read this section carefully and ensure that any required access holes register plates or flue connections are in place before carrying out the installation If the installation is to be back filled with vermiculite concrete the convection chamber flange should be sealed to the fireplace using fire cement heat proof silicone or similar material All seams in the convection chamber should also be sealed It is recommended that the convection chamber flange is sealed to the fireplace in all cases as this will reduce the chance of airflow into any voids reducing the stoves efficiency or the ingress of unpleasant smells into the room If fitting the Direct Air Adaptor Kit the instructions supplied with the kit should be read in conjunction with these instructions 1 Offer the convection chamber into position in the recess pushing it back far enough so that the flanges on the edges are pushed up tightly against the front face of the chimney breast fireplace 2 Drilla6mm hole into the hearth in the centre of the base plate fixing hole Use the screw supplied to fix the convection chamber in place Any voids around the stove must be in filled with vermiculite concrete with a recommended mix of six parts vermiculite to one part Ordinary Portland Cement This may be carried out once the flue has been fitted provided a suitable access hole for backfilling is made in the chimney breast see sec
16. n Duct Kit the dimensions of the opening may need to be altered Read the instructions supplied with the kit before proceeding INSTALLATION INTO A SOLID NON COMBUSTIBLE WALL This stove must be fitted on a hearth or base with adequate load bearing capacity The opening into which this stove is fitted should be constructed wholly from non combustible 6 0 F materials The dimensions of the opening should be at least those shown in the diagram Ensure there is a sufficient overlap where the convection chamber flange meets the face of the opening If not either the opening should be made smaller or a suitable fire surround should be fitted to reduce the opening dimensions Any non combustible walls within 50mm of this appliance should be at least 200mm thick and should extend at least 300mm above the top of the appliance and at least 1 2 metres above the hearth Any walls more than 50mm from the appliance may be reduced to a thickness of 75mm Ensure the inter connecting flue pipe also has adequate clearances to combustible materials The wall above the stove will become hot and should therefore be finished in a heat resistant plaster IMPORTANT Do not hang pictures electrical equipment or ornaments above the stove as these could be damaged and could potentially create a fire hazard This area to be finished in heat resistant plaster HEARTH REQUIREMENTS A constructional hearth with a minimum thickness of 125mm shou
17. n heat resistant plaster e Particular attention must be paid to the size and position of ventilation openings These openings must be kept clear at all times 10 All flue pipe within the enclosure must be insulated twin wall flue pipe suitable for solid fuel as specified in Table 1 on page 3 factory made metal chimney If fitting the Direct Air Adaptor Kit the adaptor box and ducting must be insulated with 30mm thick Rockwool Rocklap H amp V Pipe Sections having a nominal density not less than 120kg m If fitting the Convection Duct Kit the ducting within the enclosure must also be insulated with 30mm thick Rockwool H amp V Pipe Sections having a nominal density not less than 120kg m as per the instructions supplied with the kit The clearances to combustible The diagrams on page 11 show the material shown on page 7 must be dimensions of the approved enclosure met N B the side distance is for arrangement material proud of the front face of the wall The enclosure should be stood wholly above a non combustible hearth with a minimum thickness of 12mm The hearth should extend at least 225mm in front of the stove and 150mm either side The hearth may be super imposed Enclosure Details all dimensions in millimetres 450 SECTION A A All panels including heat shield to be produced from 30mm Skamol Super Isol board Internal heat shield JE a DETAIL
18. nd not more than 200mm If these requirements are not met the chimney should be lined by a suitable method If there is no existing chimney then either a prefabricated block chimney in accordance with Building Regulations Approved Document J or a twin walled insulated stainless steel flue to BS EN 1856 can be used These chimneys must be fitted in accordance with the manufacturer s instructions and Building Regulations Masonry or flue block T400 N2 D3 G Clay Flue Blocks FB1 N2 El n BS EN 1457 2009 a BS EN 1857 2003 Factory Made Metal Table 1 Minimum Flue Designations The chimney flue should have a vertical height of at least 4 5 metres and should terminate in accordance with Table 2 If the chimney is believed to have previously served an open fire installation it is possible that the higher flue gas temperature from the stove may loosen deposits that were previously firmly adhered with the consequent risk of flue blockage It is therefore recommended that the chimney is swept a second time within a month of regular use after installation If you have any doubts about the suitability of your chimney consult your local dealer stockist Both the chimney and flue pipe must be accessible for cleaning and if ANY part of the chimney cannot be reached through the stove with baffle removed a soot door must be fitted in a suitable position d FLUE DRAUGHT If the draught exceeds the recommended b maximu
19. of any work Starting HEALTH AND SAFETY PRECAUTIONS Special care must be taken when installing the stove such that the requirements of the Health and Safety at Work Act are met PACKAGING All packaging supplied with this stove can be re used or recycled Please contact your local authority for information on recycling schemes in your area HANDLING Adequate facilities must be available for loading unloading and site handling FIRE CEMENT Some types of fire cement are caustic and should not be allowed to come into contact with the skin In case of contact wash immediately with plenty of water ASBESTOS This stove contains no asbestos If there is a possibility of disturbing any asbestos in the course of installation then please seek specialist guidance and use appropriate protective equipment METAL PARTS When installing or servicing this stove care should be taken to avoid the possibility of personal injury AIR SUPPLY The room or space containing this appliance should have purpose provided ventilation where necessary in accordance with Building Regulations Due consideration should be given to air requirements for any other appliance in the Same room or space Any air opening must be kept clear from blockage or obstruction MODIFICATION No unauthorized modification of this appliance should be carried out SAFETY WARNING This appliance will be hot when in operation and due care should be taken
20. our stove to its maximum heat output This is to allow the paint to cure in steadily and to give a long service life to the paint finish During this curing in process you may notice an unpleasant smell It is non toxic but for your comfort we would suggest that during this period you leave all doors and windows open Open both air controls fully and light one or two firelighters placed centrally on the grate allowing the flames to become established before placing several pieces of small dry kindling in a crisscross fashion above the firelighters taking care not to smother the fire Close the stove door Once the kindling is well alight open the door and build the fire by gradually adding slightly larger pieces of wood closing the door afterwards Once the fire is established close the Ignition Air Control anti clockwise and add more fuel as necessary The Combustion Air control can 15 now be used to regulate the burn rate of the stove see Recommended Settings Should the fire fail to light correctly open the door and use a poker to spread the fuel across the grate Close the door and allow the fuel and stove to cool before attempting to relight the fire N B Leaving the air controls in the closed position adding too much fuel or using wood that is wet or too large will prevent the fire from establishing correctly and may result in smoke emission from the stove When the stove is up to operating temperature the oper
21. release it from the latch and swing it to the right If the door handle is swung past the point where resistance is felt the door will be unlatched and may swing open When the stove is hot the door handle can be released by pressing the end of the operating tool against the arm below the handle This will prevent damage to the paint Alternatively a glove can be used Combustion Air Control Ignition Air control regulates air flow directly into the firebed This is used when lighting from cold or when reviving a fire that has nearly burnt out Turn clockwise to open and anti clockwise to close The Ignition Air Control must be closed once the fire is established Combustion Air Control regulates the flow of air downwards into the combustion chamber via the airwash airflow over the inside of the glass and the air inlet at the back of the firebox below the tertiary air inlet see below Turn clockwise to open and anti clockwise to close This control is used to regulate the burn rate and therefore heat output of the stove Tertiary Air Tertiary Air enters the firebox through the series of holes in the rear wall This air supply helps to reduce emissions into the atmosphere The tertiary air supply is fixed and cannot be adjusted N B When closing the door keep the door handle out to the right until the door is closed LIGHTING We recommend that you have two or three small fires before you operate y
22. rvision of smoke control areas and you can contact them for details of Clean Air Act requirements The Di Lusso R5 has been recommended as suitable for use in Smoke Control Areas when burning wood logs RECOMMENDED FUEL IMPORTANT Use only recommended fuels This appliance is designed and approved to burn wood logs with a moisture content not exceeding 20 The maximum recommended log length is 350mm 14 and the maximum recommended log diameter is 100mm 4 Do not load fuel higher than the bottom of the compound tertiary cover Burn only dry well seasoned wood which should have been cut split and stacked for at least 12 months with free air movement around the sides of the stack to enable it to dry out Burning wet or unseasoned wood will create tar deposits in the stove and chimney increase harmful emissions and will not produce a satisfactory heat output Do not burn waste mineral fuel or treated or painted wood in this appliance AIR CONTROLS Installed and used correctly this stove will burn cleanly and efficiently Therefore to avoid the disappointment of poor performance or dirty glass please familiarize 14 Ignition Air Control yourself with the controls and their recommended settings before use To prevent excess smoke emissions the air controls of this appliance must only be operated as directed in the instructions a AS To access the air controls press on the door handle to
23. the firebox and removing it Air Valve Cassette the removal procedure is shown on page 5 Grate remove the log retainer and ash pan and then lift the front of the grate up until it is free from the ignition air bar before sliding it out of the stove Side firebricks remove the baffle brick and grate Lift the side bricks away from the base and remove Rear Firebricks remove the side firebricks and swing the base of either rear brick towards the front of the stove 16 MONTHLY MAINTENANCE Baffle Brick this should be removed and cleaned at least once a month to prevent any buildup of soot or ash that could lead to blocked flueways Firebricks in normal use these can last for many years It is possible however to damage them if care is not taken when refueling the stove Check periodically for seriously cracked bricks which can be replaced with new available from your dealer Air Valve Cassette this should be removed and cleaned monthly to remove any ash that may be in the controls N B Make sure that the controls are in the maximum position turned fully clockwise before removing the air valve cassette Glass Panel clean the glass panel when cool with a proprietary stove glass cleaner Highly abrasive substances should be avoided as these can scratch the glass and make subsequent cleaning more difficult ANNUAL MAINTENANCE Annual maintenance of the following should be carried out b
24. tion on connection to an existing masonry chimney Sufficient water should be added so that when a handful of the mixture is squeezed no more than one or two drops of water are released FLUE CONNECTION The flue connection is made to the convection chamber and not to the firebox The connection between the flue and firebox is completed when the firebox is re fitted to the convection chamber Dependent on the type of installation the flue collar may need to be connected to the convection chamber before or after installation of the flue liner 1 Remove the flue collar by undoing the four countersunk screws that secure it in place 2 Determine the required orientation of the flue collar vertical or leant backwards by 30 3 Offer the flue collar into position from inside the convection chamber and fix in place using the four M8 countersunk screws Ensure that the screw heads are not proud of the flue collar flange If connecting to a stainless steel liner the flue liner and single skin adaptor can be lowered down the chimney and the spigot end of the adaptor lowered into the convection chamber The flue collar can then be connected to the adaptor The completed flue collar assembly can then be pushed up to the top of the convection chamber and secured in position using the four M8 countersunk screws Check the clearance of the flue liner adaptor through the top of the convection chamber b
25. y a competent person Chimney and flueways it is important that the chimney flueways and any connecting pipe are swept regularly This means at least twice a year for Woodburning appliances Only wire centered sweeps brushes fitted with a guide wheel should be used If it is not possible to sweep all parts of the chimney through the appliance ensure there is adequate access to cleaning doors If the stove is fitted in place of an open fire the chimney should be swept one month after installation to clear any soot falls which may have occurred due to the difference in combustion between the stove and the open fire PERIODS OF PROLONGED NON USE If the stove is to be left unused for a prolonged period then it should be given a thorough clean to remove ash and unburned fuel residues To enable a good flow of air through the appliance to reduce condensation and subsequent damage leave the air controls fully open If the appliance has been unused for a long period such as during the spring and summer months a competent person should check the chimney for potential obstructions before lighting the stove i e get the chimney swept before the start of the heating season As NECESSARY Stove Body the stove is finished with a heat resistant paint and this can be cleaned with a soft brush Do not clean the stove whilst it is hot wait until it has cooled down The finish can be renovated with proprietary stove paint
Download Pdf Manuals
Related Search
Related Contents
M16C R8C Compact Emulator Debugger V.1.02 User's Manual Mode d`emploi de poche Goodmans GDR10 User's Manual Comman SPANIS Manual COM028 - dia MODE D`EMPLOI POUR LA REGULATION DE Tricity Bendix DSIE328 Cooktop User Manual Manuel d`utilisation Installation Manual.cdr Doc - France Industrie sa Dicota PerfectSkin Color Copyright © All rights reserved.