Intaeco Solarfill2 operating instructions
Contents
1. 45 FOR INSTALLING AND USING Solarfill 2 thermal filling set Solarfill 2 operating instructions Introduction The Intaeco Solarfill 2 is a solar thermal filling set designed to make the filling and flushing of aqueous glycol based systems easy Solarfill 2 features a robust trolley type design with swivel wheels allowing it to be easily manoeuvred into position in the plant room Key features Increased capacity 30 litre solar fluid tank with large lid for easy filling New 0 5 Hp pump Reduced noise level during operation Filling port with shut off ball valve and flexible connection hose Flushing de aeration port with shut off ball valve amp flexible hose Clear large capacity bowl filter replaces old Y strainer Pressure gauge High output filling pump with cast iron body and brass manifold Variable pressure regulator to set fill pressure Inlet for connection to an external tank Optional manual pump for pressurising without electrical power By employing the Solarfill 2 cleaning draining venting and filling of pipe systems is made much easier and can take place in a single operation It s also no longer necessary to work on the roof adjacent to the solar array and solar air vents on the roof can be omitted from the system design System debris can also be flushed out through the inbuilt strainer Instructions for use Filling method ball valve closed solar fluid in Pressure gauge
2. air amp debris outy Bowl filter re ee AA AE Pp isolation valve Inlet when tank is not Filling pump used with isolation valve Solarfill 2 operating instructions Read before operating Solarfill 2 Never run the pump set unmanned Avoid running the pump without fluid Hot fluid returning from the collectors can pose a scalding risk Temperatures can exceed 60 C On sunny days cover the collectors or avoid filling the system during the hottest part of the day Ensure the flexible connection pipes are fitted to the correct connections on the pump set and system Only use on aqueous and aqueous glycol systems If required clean or flush the solar fluid tank with the strainer open Use bund trays and avoid operation with wet hands Filling and flushing These instructions should be used in conjunction with the instructions for the components contained within the solar thermal installation Before filling and flushing carry out system checks and ensure the solar expansion vessel has the correct gas charge 1 Securely fit the connection hoses to the solar thermal system Use the connections on the solar pump Station if installed 2 When using the integral tank use a funnel and a bund tray and carefully fill the integral tank When using IBC or external solar fluid containers or tanks dip the flexible inlet hose in the container 3 Depending on the source of the fluid either open the isolation valve below the integral t
3. ank or the isolation valve at the side of the pump set outlet Whichever one is open the other must be shut 4 Open the outlet isolation valve 5 Close the isolation valve between the flushing and filling points on the solar pump station 6 Open the flushing and filling isolation valves on the solar pump station Switch on the Solarfill pump set and refill the tank when necessary Always turn the pump off when refilling the tank There is no need to use the isolation valves as there is a non return valve on the discharge side of the filling pump 8 Fill and flush until there are no more bubbles visible in the integral tank Then continue for 15 minutes to deaerate 9 Close the flushing isolation valve and pressurize to the required fill pressure 10 Switch off the filling pump and shut off the filling isolation valve on the solar pump station 11 Where vents are used deaerate the system and recharge using the filling pump set when necessary 12 Switch on the solar circulation pump using manual output on the solar controller and allow it to run for 1 hour 13 Deaerate again using vents where provided and refill to required pressure if necessary 14 Shut off the inlet and outlet isolation valves on the filling set 15 Carefully remove the connection pipes from the solar pump station avoid spills using a bucket or container Then drain down the flexible pipes Important Most collector manufacturers recommend not to fill
4. m Technical details Max flow rate 23 litres per minute Max pressure 5 barg Size 390mm d x 320mm w x 780mm h with wheels Connections 3 4 BSP male Weight 15 5kg when empty Electrical 230v 110v options Net frequency 50Hz Motor IP55 Min Glycol temp 05 C Max Glycol temp 35 C Solarfill 2 operating instructions Position Description Quantity Cap Gasket E Hexagon nut Handle Washer Cap 3 4 Seal Tank Tap 90 Tank stand Screw Console plate Screw Tap straight Hexagon nut Washer Screw Base support Wheel Hexagon nut Washer Hexagon nut Anti vibration Outlet tube Nipples O ring Pressure gauge Pump Washer Screw Tube filter Nipples Filter Inlet tube Component Parts NO BRN PR m N m Jt PRENPERBRRPPNNFPNARRRPRENNBHR ENE BD Intaeco Limited Airfield Industrial Estate Hixon Staffordshire ST18 OPF t 01889 272190 f 01889 272191 e sales intaeco co uk w www intaeco co uk
5. the system when the collectors are hot Therefore either fill the system during times of the day when the collectors are cooler i e 1st thing in the morning or late afternoon or better still cover the collectors I I Solar pump station i Solarfill filling pump set i Solarfill 2 operating instructions Troubleshooting Peete Case Remedy The motor does not start There is no voltage Check fuses or loose contacts and check the value of line voltage The capacitor is ineffective Replace the part Low supply voltage or line drop Increase the voltage within the nominal limits specified The electric motor is running but The filter is clogged Clean the filter the pump is not producing pressure The suction tube is clogged Remove amp clean Check seals are undamaged The pump is by passing the system Check valve positions on the pump station System is not in pressurise test Shut the out valve on the pump Station Pressurise configuration to 4 bar turn off system inlet and outlet valves then turn off the electric power The over heat safety switch cuts Excessive overheating of the electric Check voltage and fan out the electric motor motor The electric motor is damaged Contact Intaeco Customer Services Hose connections leaking The seals are damaged Replace seals On system test pressure is lost Check the hose seals first before Tighten joints checking the system for leaks If no leaks then check the syste
Download Pdf Manuals
Related Search
Related Contents
紙折機F-260(PDF:2.61MB) XFX NVIDIA GeForce 8800 GTS 640MB DDR3 XXX Version GeForce 8800 GTS Unity™ for Vari-Flex CATS User Manual Manual do Usuário - Toledo do Brasil Table of Content JVC Arsenal KD-AR800 CD Player Grundig 28 VLE 5401 BG 28" HD-ready Black Freatichem Model AVR-32 Manual Copyright © All rights reserved.