Home
        Operating Instructions - Stahl
         Contents
1.      Observe national safety and accident prevention regulations       Only run the device according to its performance data       Servicing maintenance or repair work which are not described in the operating  instructions must not be performed without prior agreement with the manufacturer       Any damage may render explosion protection null and void       No changes to the devices or components impairing their explosion protection are    permitted        Install and use the device only if it is undamaged  dry and clean     If you have questions      Contact the manufacturer     3 2 Warning notes    Warnings are sub divided in these operating instructions according to the following    scheme     Z WARNING    Type and source of the danger      gt  Possible consequences           Measures to avoid danger   They are always identified by the signalling word    WARNING  and sometimes also have  a symbol which is specific to the danger involved     150646   8570601300    S BA 8570 11 12 04 en 1 7 06 2009 E       Wall Mounted Socket  Plug 3  8570 11  8570 12    Intended Area of Application    3 3 Conformity to Standards  The wall mounted socket 8570 11 and plug 8570 12 comply with the following directives  and standards   X Directive 94 9 EC  X IEC EN 60079 0  IEC 60079 1  IEC EN 60079 7  IEC EN 60079 11  X IEC EN 61241 1  X IEC EN 60947 3  IEC EN 60947 4 1  IEC EN 60309  IEC EN 60529    4 Intended Area of Application  The wall mounted socket 8570 11 and plug 8570 12 are explosion 
2.    Ke   U  Klausmey  Regierungsdirektor    sheet 1 3         EC type examination Certificates without signature and official stamp shall not be valid  The certificates may be circulated  only without alteration  Extracts or alterations are subject to approval by the Physikalisch Technische Bundesanstalt   In case of dispute  the German text shall prevail     Physikalisch Technische Bundesanstalt e Bundesallee 100   D 38116 Braunschweig    Wall Mounted Socket  Plug 150646   8570601300    8570 11  8570 12 S BA 8570 11 12 04 en 17 06 2009       EC Type Examination Certificate    13 2 EC Type Examination Certificate  current supplement        Physikalisch Technische Bundesanstalt    Braunschweig und Berlin    Ist SUPPLEMENT  according to Directive 94 9 EC Annex III 6    to EC TYPE EXAMINATION CERTIFICATE PTB 03 ATEX 1227     Translation     Equipment  Plug and socket device  type 8570           Marking          112G EEx ed  ia  IIC T6  2D IP66 T80  C    Manufacturer  R  STAHL Schaltger  te GmbH    Address  Am Bahnhof 30  74638 Waldenburg  W  rtt    Germany    Description of supplements and modifications    e The wall mounting socket outlet  mounted in a basket guard  is designed as a portable  socket outlet   The type name for this version is  8570  6        e The cable entries used may also be of a type permitting mobile applications as certified under a  separate test certificate  The screw threads are mounted with interference fit  using a tool    e The inner contour line of t
3.    Operating Instructions        Sal Wall Mounted Socket    ConeX Plu g     gt  8570 11  8570 12       Contents    1    2 1    2 2    2 3    Contents   1 NE mare ai E E E E E E 2  2 G  neral NNN 2  3 General Notes Regarding Safety          rrrnnnnnnnnnnrnanrnnnrnnnnrnanenanennnennannnannnannnnnennnannene 3  4 Intended Area of Application          rrrrrarennrnnnrnnnennnrnnrnnernanerannnnnnnnennnenunnnusnnnennsenuneneene 4  D FEN WIAA  E D  6 Transport  Storage and Disposal        rarranenannnnnnnernanennrnnernnnnnannnernnnennnnnnsnnnenneenuneneenn 9  7 AN E 10  8 It UE Le W   11  9 COMMI SONN E 13  VAN EE 13  CE Ou Tuer 14  12 Accessories and Spare Parts        rrrrrnanennnenannnennnnrnnnennnnnnnnnnennnnnnnnneennnennnnnennnnennnen 15  13 EC Type Examination Certificate             rrrrarerarernorrnnrrnarernnrrnnennnrnnanenanennnernnnnaennne 16  14 EC Declaration of Conformity           rrrrrrrareranenanernrnnnnrvanernnrrarnnnnnnanenanenanennsannasennee 18    General Information    Manufacturer  R  STAHL Schaltger  te GmbH  Am Bahnhof 30  74638 Waldenburg  Germany    Phone   49 7942 943 0    Fax      49 7942 943 4333    Internet  www stahl de    Information Regarding these Operating Instructions   ID NO   150646   8570601300   Publication Code  S BA 8570 11 12 04 en 17 06 2009  We reserve the right to make technical changes without notice     Symbols Used    Action request   Describes actions to be carried out by the user    gt  Reaction sign   Describes the results or the reac
4.   2 5 mm  solid  finely stranded    1xM25x1 5  1xM25x1 5  7 mm    17 mm    Cable entries on top and rear side     1 x M25 metal cable gland  see R  STAHL Catalogue  Chapter 12      8570 11 3 1 12 kg  8570 11 4 1 35 kg  8570 11 5 1 45 kg  8570 12 3 0 31 kg  8570 12 4 0 38 kg  8570 12 5 0 43 kg    5000 switching cycles  electrical and mechanical     max  1 2 Nm    max  1 8 Nm    8570 12  see sockets 8570 11    8 mm     20 mm    max  1 0 Nm       150646   8570601300    S BA 8570 11 12 04 en 17 06 2009    Technical Data    Dimension drawings  all dimensions in mm    subject to alterations       10338E00 10333E00    8570 11 4   and 8570 11 5         Type  8570 12 3    16A 2P    8570 12 4    16A 3P      8570 12 5    16A 3P N         10337E00    8570 12       150646   8570601300 Wall Mounted Socket  Plug 7  S BA 8570 11 12 04 en 17 06 2009 8570 11  8570 12       Technical Data    Position of the protective earth  PE  contact    Position  clock hour position  View  front face of the socket    1 3 Example  clock hour position       06190E00    250 V   6 o clock       02395E00    Contact layout and terminal markings    2P 4 3P 4 3P N 4       06190E00  06556E00 06555E00    8570 11 3   8570 11 4   8570 11 5      Contact layout and terminal markings in the 6 o clock position  view from the front face of shrouded socket onto the contacts      8 Wall Mounted Socket  Plug  8570 11  8570 12    150646   8570601300  S BA 8570 11 12 04 en 17 06 2009       Transport  Storage and Disposal    Conta
5.  ia  IIC T6    Ex de IIC T6  Ex de  ia  IIC T6    x   Il 2 D Ex tD A21 IP66 T80   C  Ex tD A21 IP66 T80   C      30  C      55   C    50   C on request  internal lubrication with silicone grease     PTB 03 ATEX 1227  IECEx PTB 05 0023    PTB 03 ATEX 1227   IECEx PTB 05 0023   GL 26 296   05 HH  Germanischer Lloyd   2P 4  3P t 3P N 4   optionally  2 pieces   ON   delayed  OFF  advanced    max  690 V AC  max  110 V DC    max  500 V AC   110 V DC  0 Hz    60 Hz    10        6     16 A  max  6A    Main contacts     AC 3 690 V 16A   4 kW 220 V  230 V   240 V  7 5kW 380 V 400 V   415 V   500 V  11 kW 600 V   690 V   DC1 110 V 16 A  Auxiliary contacts    AC 15 500 V max  1250 VA  AC 15 230 V max  1380 VA  AC 12 500 V max  3000 VA  DC 13 110 V 110 W   16 A gl   35 A gL    Actuator is lockable in 0 and I position    Wall Mounted Socket  Plug  8570 11  8570 12       Technical Data    Technical Data    Material   Enclosure  Degree of protection  Type of connection  Connection cross section    Main contacts    Auxiliary contacts  Cable entries  Stopping plug  Cable gland  Cable dia  range    Special version    Weight    Service life  Tightening torque  Terminals    Connection chamber  cover    Plug   Further technical data   Cable connection  Cable dia  range   Tightening torque    Plug enclosure    Wall Mounted Socket  Plug  8570 11  8570 12    Polyamide  glass fibre reinforced  IP66    Screw terminals    12 x 1 5 mm      6 mm  solid  2x 1 5 mm      4 mm  finely stranded    2 x 0 5 mm  
6.  if necessary       Clean the connection chamber if necessary       Check that the cables enter the casing correctly     gt  Check tighten all screws  bolts and nuts     gt  Check tighten all cable entry glands and sealing plugs     gt  Observe the mains voltage       Seal all cable entries  which are not used  with plugs certified in accordance with  directive 94 9 EC and seal all holes  which are not used  with sealing plugs certified in  accordance with directive 94 9 EC       Only operate if fully assembled     10 Operation         The wall mounted socket and plug must only be operated if fully assembled     10 1 Operation  wall mounted socket  type 8570 11        L    X The wall mounted socket switch can only be operated if a plug is inserted     X When the plug is disconnected  lock the hinged cover with the bayonet  ring   Only type 8570 12 and 8575 12 plugs  manufactured by R  STAHL  must be used     10 2 Operation  plug  type 8570 12      If a short circuit occurs in the circuit  to which the plug is connected  check the function of  the plug        The plug can be operated together with the following products manufactured by  R  STAHL     X Wall mounted sockets 8570 11  8575 11  8575 13  7570 11 and 7575 11  X Flange sockets 8570 15 and 8575 15   X Coupling sockets 8575 14 and 8575 16   The plug fits industrial sockets  compliant with CEE standard      150646   8570601300  S BA 8570 11 12 04 en 1 7 06 2009       Wall Mounted Socket  Plug 13    8570 11  8570 12    Ma
7. 1 7 06 2009       
8. ct layout and identification colour and terminal markings    Number of poles Frequency  Hz  Voltage  V  Identification colour Position of the PE  contact  60 250 440   265 460 1  red 11 o clock    Identification colour and layout in relation to the keyway for the various voltages and frequencies  in accordance with IEC EN 60309 2  1  Primarily for installation on board ships    2  Frequencies   100 Hz lead to increased heating behaviour  This must be compensated for by a max  ambient temperature  of  lt  40   C  temperature class T5 or a reduction of current to 12 A     6 Transport  Storage and Disposal    Transport     Shock free in its original carton  do not drop  handle carefully     Storage       Store in a dry place in its original packaging      Storage temperature range    55   C       80   C    Disposal       Ensure environmentally friendly disposal of all components according to legal  regulations     150646   8570601300    Wall Mounted Socket  Plug 9  S BA 8570 11 12 04 en 17 06 2009    8570 11  8570 12       Assembly    7 Assembly    7 1 Assembly  wall mounted socket  type 8570 11         8 If exposed to the elements  the casing must be provided with a protective  Canopy or wall     Position for use  Hinged cover down  connection chamber up       Fasten the wall mounted socket  in a vertical position  to a flat wall  using four screws     L    The securing holes are elongated  This allows the casing to be adjusted both  vertically and horizontally     Assembling t
9. h  have an EC Type examination certificate     gt  Conductor insulation must reach right to the terminal       The conductor must not be damaged  e g  notched  when stripping the  insulation       Always connect the protective earth conductor    8 1 Installation wall mounted socket  type 8570 11  L     Two conductors can be clamped under a single terminal  Conductor material  and cross sectional area must be identical  The conductors can be connected   without special preparatory measures   Dimensions  mm  A   Main contacts   Auxiliary contacts   Auxiliary contacts Ex        Open enclosure       Pass the cable through the cable entry into the connection chamber       Insert the conductors into the corresponding terminals and clamp them  tightening  torque  see Chapter 5     Technical Data    The stripped ends of the wire must be fully  beneath the terminal clamping plate       Align the wires  clamped ends must be relieved of strain      gt  Tighten the cable gland s        Close enclosures  Tightening torque see Chapter 5 Technical Data    150646   8570601300 Wall Mounted Socket  Plug 11  S BA 8570 11 12 04 en 17 06 2009 8570 11  8570 12       Installation    Installing auxiliary contacts       11202E00     gt  Open enclosures       Pass the cable through the cable entry into the connection chamber       Unlock screwless terminals with a slotted screwdriver 0 6x3 5 mm   ISO 2380  2  and secure  stripped wire ends  The stripped wire ends must be entirely placed under the clam
10. he auxiliary contacts       11203E00       Open enclosure       Insert the auxiliary contacts into the left or right receptacle  until they engage    Both can be fitted if necessary       Close the casing     7 2 Assembly  plug type 8570 12        L    ITo prevent dirt from contaminating the contacts  a compatible sealing cap can  be used  see Chapter 12     Accessories and Spare Parts      Position for use  When the plug is disconnected  it must be hung with the pins pointing   downwards     150646   8570601300  S BA 8570 11 12 04 en 1 7 06 2009    10 Wall Mounted Socket  Plug    8570 11  8570 12       Installation                   8 Installation  AA WARNING   Danger from live parts     gt  Risk serious injury       All connections and wiring must be disconnected from the power supply       Secure the connections against unauthorised re connection    Z WARNING   Danger of explosion     gt  There is a risk of injury to persons and material damage       Choose a suitable conductor  so that the maximum permissible  conductor temperature is not exceeded       If using wire end ferrules  fit these in a gastight manner using the  appropriate tool       Only use 2 core cables  without screen braiding in intrinsically safe circuits   Observe the insulating capacity and spacing between intrinsically safe and  non intrinsically safe circuits  in accordance with IEC EN 60079 11 and  IEC EN 60079 14  section 12       Only use separately tested cable entry glands and sealing plugs  whic
11. he switch element has been modified    e Alternative materials are used for the plug and socket device     Applied standards  EN 50014  1997   A1   A2 EN 50018  2000   A1 EN 50019  2000  EN 50020  2002 EN 50281 1 1 1998    Test report  PTB Ex 05 15305    Braunschweig  February 10  2006    Sheet 1 1          EC type examination Certificates without signature and official stamp shall not be valid  The certificates may be circulated  only without alteration  Extracts or alterations are subject to approval by the Physikalisch Technische Bundesanstalt   In case of dispute  the German text shall prevail     Physikalisch Technische Bundesanstalt   Bundesallee 100   38116 Braunschweig  Germany    150646   8570601300 Wall Mounted Socket  Plug 17  S BA 8570 11 12 04 en 17 06 2009 8570 11  8570 12       EC Declaration of Conformity    14 EC Declaration of Conformity    EG Konformitatserklarung  EC Declaration of Conformity  D  claration de Conformit   CE            Wir  we  nous          R  STAHL Schaltgerate GmbH  Am Bahnhof 30  74638 Waldenburg  Germany   69 0              erkl  ren in alleiniger Verantwortung  dass das Produkt Steckvorrichtung  hereby declare in our sole responsibility  that the product Plug and socket  d  clarons  sous notre seule responsabilit    que le produit Prise de courant         mit der EG Baumusterprifbescheinigung    under  EC Type Examination Certificate  PTB 03 ATEX 1227  avec  Attestation dexamen CE de type              auf das sich diese Erkl  rung bez
12. ieht  mit den folgenden Normen oder normativen  Dokumenten   bereinstimmt   which is the subject of this declaration  is in conformity with the following standards or normative  documents   auquel cette d  claration se rapporte  est conforme aux normes ou aux documents normatifs suivants              Nummer sowie Ausgabedatum der Norm  Number and date of issue of the standard  Num  ro ainsi que date d   mission de la norme    Bestimmungen der Richtlinie  terms of the directive  prescriptions de la directive                   EN 60079 0 2006  EN 60079 1 2007  EN 60079 7 2007  EN 61241 0 2006  EN 61241 1 2004    94 9 EG  ATEX Richtlinie  94 9 EC  ATEX Directive  94 9 CE  Directive ATEX              2004 108 EG  EMV Richtlinie  2004 108 EC  EMC Directive  2004 108 CE  Directive CEM          Qualit  tssicherung Produktion   Production Quality Assessment  PTB 96 ATEX Q006 6  Assurance Qualit   Production     Kenn Nr  der benannten Stelle   Notified Body number   N   de Forganisme de certification  0102                     p   p  5 Waldenburg  08  Sept  2009 i V    a hue LV  77  go    5 7  5 Ort und Datum B  Limbacher Dr  S  Jung     Place and date Leiter Entwicklung    Leiter Qualit  tsmanagement  e Lieu et date Head of Development Director Quality Management Dept   3 Directeur D  veloppement Directeur Dept  Assurance de Qualit    18 Wall Mounted Socket  Plug 150646   8570601300       8570 11  8570 12 S BA 8570 11 12 04 en 17 06 2009    150646   8570601300  S BA 8570 1 1 12 04 en 
13. intenance    11 Maintenance    AA WARNING  Danger from live parts    gt  Risk serious injury      All connections and wiring must be disconnected from the power supply      Secure the connections against unauthorised re connection     A  WARNING  Danger through defective switch contacts    gt  There is a risk of injury to persons and material damage      The complete flange socket must always be replaced  if a short circuit occurs  in the switch s main circuit  as the state of the switch contacts of hermetically sealed  devices can not be determined        Regular Maintenance Work      Refer to the corresponding national regulations  e g  IEC EN 60079 17  for the type  and scope of tests       The maintenance intervals must be chosen  such that the occurrence of deficiencies   anticipated in the system  can be avoided     gt  The plug must be disconnected at regular intervals  to prevent contact corrosion     The following items must be checked as part of the maintenance schedule     X Check that no cable connections are loose    X Inspect the casing for visible signs of damage    X Check that the permitted temperatures  in accordance with IEC EN 60079 0  are  adhered to    Check that female contacts are clean    Inspect seals for damage    Check that the device functions correctly    Check that surfaces of the plug pins are not damaged     x e e Ze    11 2 Cleaning    14    X Clean with a cloth  brush  vacuum cleaner or similar items    X When cleaning with a damp cloth use 
14. p plate       Align the wires  clamped ends must be relieved of strain      gt  Tighten the cable entry gland s        Close enclosures  Tightening torque see Chapter 5 Technical Data     8 2 Installation  plug  type 8570 12        12       11222E00       Screw the cable gland  1  off and remove the dust exclusion plate  2        Remove the pressure ring  3  and seal  4        Remove the shell securing screws  5  and remove the plug shell  6      gt  Insert the cable  max  4 mm   through the cable gland  1   pressure ring  3  and  seal  4   If necessary  cut the seal out to match the cable diameter     gt  Open the strain relief  7  and swivel it by 90       gt  Insert stripped cable ends in corresponding terminal and clamp  1 2 Nm   The stripped wire  ends must be entirely placed under the clamp plate     gt  The stripped ends of the wire must be fully within the terminal clamp       Swivel the strain relief back into position and fit it to the cable  The clamped end must be  relieved of strain       Fit the plug shell  insert and tighten screws  tightening torque  see Chapter 5   Technical  Data         Press the seal into the plug shell  apply the pressure ring and screw the cable gland  tight     150646   8570601300  S BA 8570 11 12 04 en 17 06 2009    Wall Mounted Socket  Plug    8570 11  8570 12       Commissioning    9 Commissioning    Before commissioning       Check for correct assembly and installation       Inspect the casing for damage       Remove foreign objects
15. protected electrical    devices     They serve the connection of portable and fixed electrical devices and the connection of  cable or circuits respectively  in areas where an explosion hazard exists     They have an area classification for use in Zones 1  2  21 and 22     A WARNING  Only use the device for its intended purpose    gt  Otherwise  the manufacturer   s liability and warranty expire      The device may only be used under the operating conditions described in these    operating instructions      The device may only be used in hazardous areas according to these operating  instructions        150646   8570601300  S BA 8570 11 12 04 en 1 7 06 2009    4 Wall Mounted Socket  Plug    8570 11  8570 12       5 Technical Data    Socket  Explosion protection  Gas explosion protection    ATEX    IECEXx    Dust explosion protection  ATEX  IECEx    Ambient temperature    Certificates  Gas explosion protection  ATEX  IECEx  Dust explosion protection  ATEX  IECEx  Marine certification  Number of pins  Auxiliary contacts  Rated operational voltage    Main contacts    Auxiliary contacts   Frequency   Voltage tolerance   Rated operational current  Main contacts  Auxiliary contacts    Rated operational power    Back up fuse  without thermal protection  with thermal protection    Operating handle    150646   8570601300    S BA 8570 11 12 04 en 1 7 06 2009    8570 11  16 A         amp  Il 2 G Ex de IIC T6  Special version with intrinsically safe auxiliary contacts     x  Il 2 G Ex de 
16. table variation thereto are specified in the schedule to this certificate and  the documents therein referred to      8  The Physikalisch Technische Bundesanstalt  notified body No  0102 in accordance with Article 9 of the  Council Directive 94 9 EC of 23 March 1994  certifies that this equipment has been found to comply with  the Essential Health and Safety Requirements relating to the design and construction of equipment and  protective systems intended for use in potentially explosive atmospheres  given in Annex II to the  Directive     The examination and test results are recorded in the confidential report PTB Ex 04 13432      9  Compliance with the Essential Health and Safety Requirements has been assured by compliance with     EN 50014  1997   A1   A2 EN 50018  2000 EN 50019  2000  EN 50281 1 1 1998     10  If the sign  X  is placed after the certificate number  it indicates that the equipment is subject to special  conditions for safe use specified in the schedule to this certificate      11  This EC type examination Certificate relates only to the design  examination and tests of the specified  equipment in accordance to the Directive 94 9 EC  Further requirements of the Directive apply to the  manufacturing process and supply of this equipment  These are not covered by this certificate      12  The marking of the equipment shall include the following      amp   112 G D EExed  ia  IIC T6 IP 66 T80 C  fizierungsstelle Explosionsschutz Braunschweig  March 24  2004     
17. tions to the actions taken     x Bullet    L      Information sign   Describes the notes and recommendations     Warning sign   Danger from energised parts     Warning sign   Danger due to an explosive atmosphere        150646   8570601300  S BA 8570 11 12 04 en 1 7 06 2009    Wall Mounted Socket  Plug    8570 11  8570 12       3 General Notes Regarding Safety    General Notes Regarding Safety    3 1 Safety instructions for installation and operating personnel  The operating instructions contain basic safety instructions which are to be observed  during installation  operation and maintenance  Non observance can lead to  endangerment of persons  plant and the environment     A WARNING  Risk due to unauthorised work being performed on the device    gt  There is a risk of injury to persons and damage to equipment        Assembly  installation  commissioning  operation and maintenance must only be       performed by personnel who are both authorised and suitably trained for this purpose     Before assembly commissioning      Read through the operating instructions        Give adequate training to the assembly and operating personnel      Ensure that the contents of the operating instructions are fully understood by    the personnel in charge        The national installation and assembly regulations  e g  IEC EN 60079 14  apply     When operating the device      gt  Ensure the operating instructions are made available on location at all times        Observe safety instructions   
18. water or mild  non abrasive  non scratching  cleaning agents    X Never use aggressive cleaning agents or solvents    X Avoid the ingress of water or cleaning agents into the female contacts     150646   8570601300  S BA 8570 11 12 04 en 1 7 06 2009    Wall Mounted Socket  Plug    8570 11  8570 12       12 Accessories and Spare Parts    Designation Illustration    Sealing plugs    Auxiliary contacts    Protection caps    05365E00    150646   8570601300  S BA 8570 11 12 04 en 1 7 06 2009          Description  8290 3 M 25 x 1 5    1 NO   1 NC   1 NO  gold contact   1 NC  gold contact   for plug 16 A 3 pole    not for extra low voltage version  for plug 16A 4 pole    for plug 16A 5 pole       Accessories and Spare Parts       Wall Mounted Socket  Plug  8570 11  8570 12    Order number  143524    150682  150680  150686  150684  150496    150510    150520    15    EC Type Examination Certificate    13 EC Type Examination Certificate    13 1 EC Type Examination Certificate  Page 1     16    Physikalisch Technische Bundesanstalt PIB    Braunschweig und Berlin        1  EC TYPE EXAMINATION CERTIFICATE     Translation      2  Equipment and Protective Systems Intended for Use in  Potentially Explosive Atmospheres   Directive 94 9 EC     3  EC type examination Certificate Number     PTB 03 ATEX 1227     4  Equipment  Plug and socket device  type 8570          5  Manufacturer  R  STAHL Schaltger  te GmbH   6  Address  74638 Waldenburg  Wirtt    Germany     7  This equipment and any accep
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
Huffy M7800041 User's Manual  Philips Activated carbon filter AC4103    Package Content Physical Installation Print Server Setup  Prevention Cannabis V5-1 - Fédération française de sport universitaire  PDFNF Trial Pack 紹介  El Portégé 2000.  Visual Basic .NET  user manual  to view pdf Elgin Part List    Copyright © All rights reserved. 