OPERATION AND INSTALLATION MANUAL FOR E/M SPEED LOG

image

Contents

1. LOCH ALIZE ENCOMBREMENT ET POSE SERES S ALIZE LOG OUTLINES AND MOUNTING CE ERU 2 Dess Drawn Ver Chec Date Jate Folio 1 1 Ind 0 CEDEX 3 BP102000 ALLEGRE NOUGIER 05 03 2001 N F0126 M Ce document est la propri t de BEN E S et ne peut tre reproduit sans son autorisation his arawing is the property of BEN ES and cannot be communicated or reproducted without authorization F0126 DWG REFERENCE 03MU006 INDICE B PAGE 13 14 Operation and Installation manual DATE ALIZE E M SPEED LOG 27 03 06 ALIZE REPEATER CONNECTION WIRES COLOUR RED SENSOR NOT USED p RS 422 RECEPTION pve i BEEN i ORANGE 12V POWER SUPPLY GREY OV YELLOW 1 200 OF MILE OUTPUT NOT USED WHITE BLUE gt RS 422 EMISSION WHITE YELLOW gt RS 422 JALARM not USED
2. 1 2 MAIN FEATURES CJ Watertight main cabinet bracket mounted Size 110x 110 x 35 mm O LCD Screen for Speed display on circular bargraph Digital speed display 0 1 knot definition Covered distance 99999 9 Covered distance with reset 9999 09 Double scale 30 or 60 n uds Average speed Water temperature CJ Brightness control 1 3 TECHNICAL FEATURES Power supply 12 Vcc 30 10 15 6 VDC 10 8 VDC Outputs 1x 1 200 of mile potential free contact output 40V 500 mA l potential free contact alarm output 50V 2A 1 RS432 NMEA 0183 format 4800 Baud 8 bits no parity 1 stop bit speed message l distance distance with reset message This document is amesys international property and cannot be copied or transmitted without the company s authorization REFERENCE 03MU006 INDICE B PAGE 6 14 Operation and Installation manual DATE ALIZE E M SPEED LOG 27 03 06 Sensor location The flat sensor surface measures the water speed along the hull This measured speed is not equal to the vessel s true speed Measured speed is lower than vessel s speed At vessel s extreme fore near true speed is obtained but towards the aft of vessel speed value differs The area along the hull where speed is different from vessel s speed is called the boundary layer Its thickness increases from fore to aft The main cause is water running along the hull which descreases up front Because of
3. This document is amesys international property and cannot be copied or transmitted without the company s authorization ELECTRODE LLECTROMES CAPTEUR SENSOR PERCAGE COQUE DRULING HULL ANNEAU D EXTRACTION s Aut ING FIL DE SECURITE SAFETY MAT ECROU CAPTEUR CAP AUT i I PIECE DE COQUE HOUSING ECROU PIECE DE COQUE v HULL NUT Oo o e RONDELLE Option WASHER Gotronal COQUE 777 od LOCH ALIZE CAPTEUR EQUIPEMENTS MASTIC SILICONE MARINE gt a MARINE SEALANT AVANT NAVIRE ZAC de Pichaury II Dess Mown Ver Chec Date Jate Folio 1 1 Ind 0 I ne DEO CEDEX 3 8PI02000 ALLEGRE NOUGIER 06 03 2001 N F0125 M E Ce document est la propri t de BEN E S et ne peut tre reproduit sans son autorisation h s arawing is the property of BEN ES and cannot be communicated or reproducted without authorization F0125 M DWG PERCAGE VERSION ETRIER DRILLING FOR BRACKET MOUNTING PERCAGE VERSION CLOISON DRILLING FOR WALL MOUNTING 4x04 5 112 VERSION SUR ETRIER BRACKET MOUNTING 126
4. the hull profile hydrodynamic penetration coefficient is minimum in the fore Speed does not depend on fouling of the hull located in the boundary layer Therefore the ratio of the vessel s speed and measured speed is constant The sensor must be located near the bow as far forward as possible It must always remain immerged if thesensor emerges occasionally this can cause a short disturbance which doesn t effect the total distance information The line joining the electrodes of the sensor must be perpendicular to the vessels longitudinal axis In case of particular installation please contact a Ben s agent After installation do not forget to clean the sensor DO NOT PAINT THE ELECTRODES DO NOT GREASE THE ELECTRODES 2 INSTALLATION AND CABLING The log is supplied with a bracket for wall mounting Its inclination is adjustable and insures an optimal using The instrument is designed for a battery power supply of 12 volts 10 30 Its average consumption is 150mA minimum lighting and 600mA maximum lighting The instrument is protected by a fuse 1A delayed The sensor cable is 5 meters long For greater lengths use a junction box max length 20 meters This document is amesys international property and cannot be copied or transmitted without the company s authorization REFERENCE 03MU006 INDICE B PAGE 7 14 Operation and Installation manual ALIZE E M SPEED LOG DATE 27 03 06 2 1 LOG CONNE
5. CTION REPEATER CABLE WIRES COLOUR RED BLACK BLUE WHITE ORANGE GREY YELLOW BROWN WHITE BLUE WHITE YELLOW GREEN PURPLE 3 9 9 3 9 9 9 KOE EE EK 4 12V o c J OV lt lt Output 1 200 of mile Output 1 200 of mile TXB RS422 output NMEA TXA RS422 output NMEA ALARM output ALARM output SENSOR CABLE WIRES COLOUR RED or PINK BLACK or GREY BLUE WHITE Power supply battery gt gt gt gt This document is amesys international property and cannot be copied or transmitted without the company s authorization REFERENCE 03MU006 INDICE B PAGE 8 14 Operation and Installation manual DATE ALIZE E M SPEED LOG 27 03 06 3 ADJUSTMENTS The keyboard comprises 3 keys DIMMER DIST RST CHRONO ALARM 3 1 Brightness adjustment Press DIMMER to adjust brightness The lighting level is indicated on the bargraph 0 corresponds to the minimum lighting 30 corresponds to the maximum lighting To execute a complete lighting adjustment cycle press the touch in continuous The brightness increases to its maximum and then decreases until quenching According to the adjustment stage press on DIMMER will increase or decrease the lighting 3 2 Daily Distance Reset Press DIST RST to reset the daily dis
6. REFERENCE 03MU006 INDICE B PAGE 1 14 Operation and Installation manual DATE ALIZE E M SPEED LOG 710808 OPERATION AND INSTALLATION MANUAL FOR E M SPEED LOG ALIZE 03MU006 B Amesys international 1030 avenue Guillibert de la lauzi re ZAC de Pichaury II 13793 Aix en Provence c dex 3 T l 33 0 4 42 60 71 15 Fax 33 0 04 42 60 70 48 e mail international amesys fr Site web www benmarine fr REFERENCE 03MU006 INDICE B PAGE 2 14 Operation and Installation manual DATE ALIZE E M SPEED LOG 27 03 06 IND Author Date Description A 19 06 03 Initial Version B JCN 27 03 06 3 1 Wires colour This document is amesys international property and cannot be copied or transmitted without the company s authorization REFERENCE 03MU006 INDICE B PAGE 3 14 Operation and Installation manual DATE ALIZE E M SPEED LOG 27 03 06 SOMMAIRE 1 DESCRIPTION PR sissa siss Ssss sostas sses s rniii 4 1 L E QUIPMENT DESCRIPTION creien a a EE A ERE E O N bu aN EEE A hen 4 L 2MAIN BEA TURES enero rere T aa ere Ld ed ERANTIS 5 1 3 TECHNICAL FEATURES erroen e a a orbe ep eee aa E E aae Ea ovencesdesesoosaacarteases 5 2 INSTALLATION AND CABLING esssesssssecssccecsecesssecsssoeesscceesscceessecesccecsscoeessecessseesscoeessoceessecsesoecescseesseceese 6 2 1 LOG CONNECTION eo irre pee r E A E E 7 J ADJUSTMENTS sovscssccssesecessconsevescsacsvoecssssevecssevendcvsscv
7. esdssoseet sehesessusevonsssssesseessesested soussdesesgsoncsvouedetabeetsecousuecese 8 3 1 BRIGHTNESS ADJUSTMENT 5 opener eher ase rne soesnnpsosed obo seasoned edb soassbopsoinbebssobeobebouss eE a Eaa E ii 8 3 2DATLY DISTANCE RESET si ssssiccisasisadeadsavavdeasdaedesssasaddantdaadendsayacdbasdaudeodessavdon sia eode esa ede de due Feo dea sat esa ds a uasa roues 8 3 3 ALARM FUNCTION oos taro oa t ee rosea sa coole doa kao dee sa ve oa T een aoa e a gave ndo doa edo dea ava ea dae aoa e esa veo do doa eod ea sae eoa see a c eode uses ends 8 3 4 DISPLAY CHANGE FUNCTION c scc0ceceseesesesesesesesesesecesecesecesecereceseseneceteseseseeesesesereseresereceseseseceeesesesenesereserens 9 3 LOG ADJUSTMENT 1 ee erisec ette E A E E tede ed ee Ie anses ee repo euer aduer era eee eri du rd 9 3 0 ZERO BASKET T m T T 9 3 GAIN ADIUSTIMENT sisi ssissssavenes 10 3 8 TEMPERATURE ADJUSTMENT cccccecceeseseseseseseseseseseseseseseseseseseeeeeseseseseseceseseseseseseseseseceseseseseeeseseseceseseeeeens 10 3 9 DAMPINGADIUSTMEN EUREN RET 11 3 JOXCHRONO EUNGTION 5412 5 5 2 ceca oreet eie ioris rade istos a a Ea O La rere eoa 11 3 11 SCALE CHANGE ON THE CIRCULAR BARGRAPH cccscssssseeeseseeeseeeseeeseseseseseseseseseseseseseseseseseseceseseeeeeseseseeens 12 Annex 1 Sensor Drawing F 0125 M Annex 2 Alize Outlines and mounting Drawing F 0126 M Annex 3 Repeater connection This documen
8. justed by equalizing absolute speed values when sensor is in normal position and is back to front Do not forget then to put sensor back in correct position red mark towards ship bow This document is amesys international property and cannot be copied or transmitted without the company s authorization REFERENCE 03MU006 INDICE B PAGE 10 14 Operation and Installation manual DATE ALIZE E M SPEED LOG 27 03 06 Instead of the distance the display shows xxx zero adjustment The touch DIST RST becomes T increase the zero value The touch CHRONO ALARM becomes t decrease the zero value The touch DIMMER becomes ENTER Go to the following menu gain adjustment 3 7 Gain Adjustment Instead of distance the display shows 2 xxx x gain adjustment in The touch DIST RST becomes T increase the gain value The touch CHRONO ALARM becomes t decrease the gain value The touch DIMMER becomes ENTER Go to the following menu Temperature adjustment 3 8 Temperature adjustment Instead of the distance the display shows 3 xx x Temperature adjustment The touch DIST RST becomes 7 increase the temperature value The touch CHRONO ALARM becomes 4 decrease the temperature value The touch DIMMER becomes ENTER Return to Main Menu This document is amesys international property and cannot be copied or transmitted without the company s authorization REFERENCE 03MU006 INDICE B PAGE 11 14 Operation and Instal
9. lation manual DATE ALIZE E M SPEED LOG 27 03 06 3 9 Damping adjustment Press simultaneously DIST RST and CHRONO ALARM to enter in damping adjustment menu Instead of distance display shows 4 xx damping adjustment The touch DIST RST becomes T The touch CHRONO ALARM becomes increase damping i decrease damping The touch DIMMER becomes ENTER Return to main menu Damping setting from 1 to 99 seconds The zero gain temperature and damping values are recorded in the microcontroller EEPROM 3 10 Chrono function Press simultaneously DIMMER and CHRONO ALARM to display 960 9 minutes 60 seconds on the main display Press a second time simultaneously DIMMER and CHRONO ALARM to display 600 6 minutes Press CHRONO ALARM to launch the account for the regatta start up Press DIMMER to return to the speed display This document is amesys international property and cannot be copied or transmitted without the company s authorization REFERENCE 03MU006 INDICE B PAGE 12 14 Operation and Installation manual DATE ALIZE E M SPEED LOG 27 03 06 3 11 Scale change on the circular bargraph The ALIZE speed log is fitted with an automatic scale change that allows a permanent optimal display When the vessel speed is higher than 30 knots the log goes automatically over the 60 knots scale The log will go over the 30 knots scale for speeds under 29 knots
10. t is amesys international property and cannot be copied or transmitted without the company s authorization REFERENCE 03MU006 INDICE B PAGE 4 14 Operation and Installation manual DATE ALIZE E M SPEED LOG 27 03 06 1 DESCRIPTION The ALIZE is a new generation of electromagnetic speed log dedicated to small ships or pleasure boats It uses an intelligent sensor The unit comprises a low speed alarm that can control an audio detector This detector can be inhibited using the keyboard on the log front face This alarm is very helpful onboard In fact the detection of the tension modification via the speed measurement is faster and more sensitive than via a tractive stress measurement 1 1 EQUIPMENT DESCRIPTION Standard equipment includes O One main cabinet with 1 LCD Screen indicating Digital and pseudo analog speed Mile totalizer 10 of mile Daily mile totalizer 100 of mile Water temperature Average speed 3 touchs keyboard O One intelligent sensor fitted with 5m cable CJ One hullfitting Options CJ RGD 100 combined repeater Digital and pseudo analog speed Covered distance with reset Covered distance without reset This document is amesys international property and cannot be copied or transmitted without the company s authorization REFERENCE 03MU006 INDICE B PAGE 5 14 Operation and Installation manual DATE ALIZE E M SPEED LOG 27 03 06
11. tance totalizer 3 3 Alarm function Alarm function is dedicated to the small trawlers It allows a prompt detection of a trawl latching Press ALARM to proceed with the alarm threshold recording The bell drawing appears The recording can be done only if the vessel speed is higher than 2 knots When the vessel speed goes under the alarm threshold the output relay contacts will be closed This document is amesys international property and cannot be copied or transmitted without the company s authorization REFERENCE 03MU006 INDICE B PAGE 9 14 Operation and Installation manual DATE ALIZE E M SPEED LOG 27 03 06 It will be open only if the vessel goes to an higher speed the alarm function is inhibited The alarm function inhibition is done by pressing again on ALARM The bell drawing disappears 3 4 Display Change Function Press at the same time DIMMER and DIST RST to display Ist pushing daily distance 2 pushing Temperature in C 3 pushing Average speed A XX XX 4th pushing Covered distance xxxxxx x 3 5 Log adjustment You can go into the adjustment mode by pressing simultaneously the three touchs 3 6 Zero adjustment When ship is motionless on dead calm water speed can be above zero You then have to correct this zero shifting Make sure there is no undertow You can easily check it by putting sensor back to front to check zero does not change If it does zero can be ad