Wireless Safety Edge System Installation Manual
Contents
1. 4 6 Installation on one leafed residential folding door with control panel with RADIOBAND RC RCS card connector PAGE 22 4 7 Installation on one leafed folding door for communities with control panel and RADIOBAND R x NN N bbs 4 8 Installation on one leafed sliding door with control panel and RADIOBAND R PAGE 23 4 9 Installation sliding door with control panel and RADIOBAND RC RCS card connector SS SOS EN AS NA S 4 10 Installation on guillotine door with control panel and RADIOBAND R PAGE 24
2. needs to be connected the jumper JP4 must be bridged This application does not comply with safety standard EN 12453 for the use of motorised garage doors since the connection of the resistive element to the RADIOBAND T is not checked OPERATION The receiver checks that all the programmed bands are working properly If a band is activated or if there is an error in its operation the receiver activates the output relay PROGRAMMING RADIOBAND T If the receiver is in programming see MANUAL PROGRAMMING on page 10 or 16 press the transmitter button to programme it into the receiver TRANSMITTER BATTERY LOW INDICATOR RADIOBAND T If the battery of a transmitter programmed into the receiver becomes low it will give out 4 short signals every 20 seconds If there is more than one transmitter programmed the safety band must be activated to check whether the receiver then makes these 4 short signals If this is the case the transmitter connected to the activated safety band will be the one with the low battery Change it CHANGING THE BATTERY Remove the box cover The batteries are positioned on the back of the cover Replace the two used batteries with new ones taking into account the polarity indicated by the connector Check that the new batteries support the same temperature range as those they are replacing PAGE 5 INSTALLATION ADVICE Install the equipment so that the cable outlet is at the bottom In installations likely to hav
3. for 2 seconds Autotest Autotest Polarity Jumper ATEST1 ATEST2 output in output type ATEST POL standby activated Connection to a 12 24V Positive Connecte Connecte equipment with d d autotest 12 24V ill idi N Connection to a ad Find equipment without connected connected autotest N B Only connect the auto test output to be used Where the auto test is not used the system is not checked at the start of the operation which means that security normative EN 12453 regarding the use of motorised garage doors is in some cases not complied with PAGE 8 LIGHT INDICATORS RADIOBAND R In operation In programming 5 Relay 1 LED Normally off On Indicates the channel to be Indicates the status of the relay output programmed If R1 is not connected on Relay 2 LED Normally off On Indicates the channel to be Indicates the status of the relay output programmed If R2 is not connected on OPERATION The receiver checks that all the programmed bands are working properly If a band Is activated or if there is an error in its operation the receiver activates the output relay MANUAL PROGRAMMING RADIOBAND R makes it possible to store 6 RADIOBAND Ts 3 on Relay 1 and 3 on Relay 2 Press the receiver programming PROG button for 1s a sound signal will be heard The receiver will go into programming the first relay If the programming button is kept pressed the receiver will go
4. negative polarisation RADIOBAND R e lt CONTROL PANEL EE Ge 23 m CS1 BS1 52 BS2 B1B2 2102210 eee RR _ _ 20 EEE EE EEE EEE EEE EEE GE KE EE cB EE ME 9 9 24Vac 24 Vac CL OP SEG CL OP FC CL OP K CO TEST SEC EDGE AUTOTEST CONNECTION NEGATIVE POLARIZATION d Auto test connection with positive polarisation RADIOBAND R CONTROL PANEL ME CL OP SEG CL OP FC CL OP AITEST SEC EDGE AUTOTEST CONNECTION POSITIVE POLARIZATION Once the system has been installed check it works correctly by enabling the safety edge on the ends of the door PAGE 13 2 3 RADIOBAND RC RCS BSC EI HC 9 E CHECK MR PROG BSO Conector para cuadro de maniobra Pulsador de programaci n Connecteur pour armoire de commande Bouton de pragrammation Connector for control panel Programming button Anschluss tur Steuerung Pragrammischalter mil Leds de indicaci n activaci n elemento de seguridad Led y pulsador de verificaci n Leds indiquant l activation de l l ment de s curit Led et poussoir de v rification Safety element activation indicator lights Check led and check button Anzergeleds for Aktivierung des Sicherhertselementes Check Led und Check Taster Power supply range PAGE 14 INSTALLATION AND CONNECTIONS Connection to a control panel using a connector for safety devices LIGHT INDICATORS RADIOBAND R In op
5. then more at a faster frequency indicating that the operation has been carried out The receiver will stay in programming mode If 10 seconds elapse without programming or if you press the programming button quickly the receiver will go out of programming mode emitting two 1s sound signals TRANSMITTER BATTERY LOW INDICATOR RADIOBAND T If the battery of a transmitter programmed into the receiver becomes low it will give out 4 short signals every 20 seconds If there is more than one transmitter programmed the safety band must be activated to check whether the receiver then makes these 4 short signals If this is the case the transmitter connected to the activated safety band will be the one with the low battery Change it PAGE 10 INSTALLATION ADVICE The transmitter and receiver antenna must be parallel to each other for optimum signal reception Do not place metal surfaces between recelver the transmitter and the Do not fit the equipment at ground level The transmitter and receiver antenna must be parallel to each other for optimum signal reception PAGE 11 a Connection to safety edge inlet RADIOBAND R CONTROL PANEL COM ATEST SEC ED E CONNECTION TO SAFETY EDGE CONTACT b Connection to security contact inlet RADIOBAND R al S CONTROL PANEL CONNECTION TO SECURITY CONTACT PAGE 12 Auto test connection with
6. RADIOBAND SYSTEM INSTALLATION MANUAL RADIOBAND SYSTEM INSTALLATION MANUAL V2 2 1 Quantek Systems Ltd CONTENTS CONTENT we 2 Inge CHON m 3 tl SVETON A AS 3 brad 3 ZO WRES EN 4 21 RADIOBABND se UM 4 22 FADEREN KE 7 25 FADIOBAND uke 14 AUTO TESS TRYNET N NE 18 S AUTOTESTPESCRIPTION tia 18 3 2 RADIOBAND RES CONNECTION Sinai dis 19 4 RADIOBAND SYSTEM INSTALLATION RECOMMENDATIONS 20 4 1 Installation on roller door with control panel and RADIOBAND R 20 4 2 Installation on two leafed swing door with control panel and RADIOBANBD RERO See 20 4 3 Installation on horizontal sectional door with control panel and KEN BIG Sy hs ra a EE 21 4 4 Installation on angled sectional door with control panel and RADIOBAND R rem 21 4 5 Installation on stackable sectional door with control panel and RADIOCAND NT NN 22 4 6 Installation on one leafed residential folding door with control panel with RADIOBANDRE ROS CONTE are idas 22 4 7 Installation on one leafed folding door for communities with control panel VPN 23 4 8 Installation on one leafed sliding door with control panel and RADIOBAND R A AEE SE 23 4 9 Installation on sliding door with control panel and RADIOBAND RC RCS cara conect
7. a 24 4 10 Installation on guillotine door with control panel and RADIOBAND R 24 5 CONTROL PANEL DIAGRAM FOR CONNECTION TO THE RADIOBAND SISTE N 25 1 INTRODUCTION 1 1 System description The Radioband system 15 designed for installation with a safety edge in automatic garage door and gate installations This system allows for wireless safety edge control panel connection To install this system you must follow the advice included in this manual and take the requirements of the applicable normative into account 1 2 Normative requirements The directives applicable to this system are 98 37 EC Machines Directive 73 23 EEC Low Voltage Directive 2004 108 EC Electromagnetic Compatibility Directive R amp TTE 1999 5 EC Radio and telecommunication terminal equipment Directive Below are some of the requirements of the applicable harmonised standards In accordance with the European low voltage directive you are informed of the following requirements For permanently connected equipment an easily accessible connection device must be incorporated into the cabling This equipment must be installed in a vertical position and firmly fixed to the structure of the building This equipment may only be handled by a specialized installer by maintenance staff or by a properly instructed operator he instructions for use of this equipment must always remain in the possession of
8. e range problems between the transmitter and the receiver the antenna must stand vertically from the hole in the gland Do not fit the equipment at ground level Do not place metal surfaces between the transmitter and the receiver The transmitter and receiver antenna LUN d must be parallel to each other for optimum signal reception Once the system has been installed check works correctly by enabling the safety edge on the ends of the door PAGE 6 2 2 RADIOBAND R 19 24v RIO ac dc 4 Pulsador de programacion Poussoir de Pragrammaton fe Puente Selector R1 Pontet S amp lecteur J3 selector Bridge R1 Steckbrucke R1 Ed Puente Selector R2 Pontet Selecteur J Selector Bridge RZ Steckbrucke RZ Leds de indicaci n activaci n rel s Leds de signalisation activation des relais Relay activated indicator lights and bow battery in Radioband T Programming button Pragrammier schalter Fontet MR pour effacement des RADIOBAND Transmetteurs Total Reset Bridge MR Reset berbr ckung Total MR 3 Led y pulsador de verificacion Led et poussoir de v rification Check led and check button Check Led und Check Taster Anzeigeleds f r die Aktivierung des Relais und Batterie fast leer in Radioband T Power supply range 9 35V DC 8 28V AC Relay contacts PAGE 7 INSTALLATION AND CONNECTIONS Fix the back of the box to the wall using the wall plugs and scr
9. eration In programming 5 Relay 1 LED Normally off On Indicates the channel to be Indicates the status of the relay output programmed If R1 is not connected on Relay 2 LED Normally off On Indicates the channel to be Indicates the status of the relay output programmed If R2 is not connected on OPERATION The receiver checks that all the programmed bands are working properly If a band is activated or if there is an error in its operation the receiver activates the output relay MANUAL PROGRAMMING RADIOBAND RC RCS makes it possible to store 6 RADIOBAND Ts 3 on Relay 1 and 3 on Relay 2 Press the receiver programming PROG button for 1s a sound signal will be heard The receiver will enter safety band closing programming mode BSC If the programming button is kept pressed the receiver will enter safety band opening programming mode BSO moving cyclically from one really to another Once the programming relay has been chosen for the transmitter you want to start using send the programming code by pressing the transmitter Every time a transmitter 15 programmed the receiver will emit a sound signal for O 5s If 10 seconds pass without programming the receiver will go out of programming mode emitting two ls sound signals If when programming a transmitter the receiver s memory is full it will emit 7 sound signals lasting O 5s and come out of programming Note For a right operation of the system the tran
10. ews supplied Install the receiver close to the door and avoid metal surfaces between the receiver and the transmitter Pass the cables through the bottom of the receiver Connect the power cables to the terminals of the printed circuit following the indications of the connections diagram Store RADIOBAND T Fix the front of the receiver to the back with the screws supplied for the purpose 1 Power supply 12 24V AC DC 2 Power supply 12 24V AC DC 3 4 R1 Connection to the safety band input of the control panel resistive contact 8 2kQ with jumper in position BS1 see CONNECTIONS Figure 1 Or to the control panel safety contact input NC with jumper in position CS1 see CONNECTION Figure 2 5 6 R2 Connection to a second safety band input of the control panel resistive contact 8 2kQ with jumper in position BS2 Or to the control panel safety contact input NC with jumper in position CS2 7 AUTOTEST Common connection safety self test See CONNECTIONS Figure 3 and table POLARIZED SELF TEST 8 AUTOTEST Self test connection for R1 See CONNECTIONS Figure 3 and table POLARIZED AUTO TEST 9 AUTOTEST Self test connection for R2 See CONNECTIONS Figure 3 and table POLARIZED AUTO TEST POLARIZED AUTO TEST Check the auto test output on the control panel in standby to see whether the voltage is OV inverted test input or 12 24V AC DC positive polarity The auto test signal of the panel must remain at its maximum
11. into programming the second relay moving cyclically from one really to another Once the programming relay has been chosen for the transmitter you want to start using send the programming code by pressing the transmitter Every time a transmitter is programmed the receiver will emit a sound signal for O 5s If 10 seconds pass without programming the receiver will go out of programming mode emitting two ls sound signals If when programming a transmitter the receivers memory is full it will emit sound signals lasting 0 55 and come out of programming Note For a right operation of the system the transmitter has to be programmed in one receiver only RADIOBAND T replacement In case you need to replace a RADIOBAND T it is necessary to reset the system see TOTAL RESET on next page and reprogram all RADIOBAND T used in the installation SYSTEM CHECK This function has to be used to check the operation and range of all the devices once the installation has been carried out Press the receiver s CHECK button for at least 1 second to enter check mode The indicator light will come on and four beeps will be heard Perform a complete door opening and closing manoeuvre During the system check a beep will be heard every 1 5 seconds CORRECT OPERATION OF THE SYSTEM If no other acoustic signal is heard on completing the manoeuvre the system 15 operating correctly Either press the CHECK button again or wait 5 minutes and the RADIOBAND R wil
12. ion and where no obstacles are expected between all RADIOBAND antennas _ Where an antenna extension is not installed place the receiver card antenna in vertical position Once the system has been installed check works correctly by enabling the safety edge on the ends of the door PAGE 17 3 AUTO TEST FUNCTION 3 1 AUTO TEST DESCRIPTION Before starting operations the control panel must check that the entire security system is working correctly The control panel shall not start Auto test during a pressed safety edge output To make this check the panel must act on the auto test signal e AUTO TEST timing correct Tena Autotest RADIOBAND T status Auto test carried out CS indicates the correct autotest of all bands Autotest OK The operation can now be carried out e AUTO TEST timing error TMAXautotest Lend Autotest RADIOBAND T status Auto test carried out CS indicates the correct 7 autotest of all Autotest Error bands THE OPERATION CANNOT BE STARED AS THE AUTO TEST HAS NOT BEEN SUCCESSFULLY COMPLETED While the auto test is being run to learn of the status of the RADIOBAND T the RADIOBAND R questions the status of the different Safety edges inputs This process ensures the correct working order of the following parts e Safety edge input e RADIOBAND T 1 or several e Channel if there is any interference e RADIOBAND R control and RF PAGE 18 sw
13. itching off the output relay means that the control status and the correct working order of the RADIOBAND R output relay has been checked Description To pes LES Tend 3 2 RADIOBAND RCS CONNECTIONS BV O 1 NC 23 H 5 R AT E ix 1 Not connected 2 RB SI Outlet 1 Radioband activation 3 Mass 4 RB S2 Outlet 2 Radioband activation D 5Vdc power supply 6 RB AT 1 Inlet 1 Radioband auto test Not connected 8 RB AT 2 Inlet 2 Radioband auto test PAGE 19 4 RADIOBAND SYSTEM INSTALLATION RECOMMENDATIONS 4 1 Installation on roller door with control panel and RADIOBAND R 4 2 Installation on two leafed swing door with control panel and RADIOBAND RC RCS PAGE 20 RADIOBAND R 4 3 Installation on horizontal sectional door with control panel and 4 4 Installation on angled sectional door with control panel and RADIOBAND R PAGE 21 4 5 Installation on stackable sectional door with control panel and RADIOBAND R
14. l exit checking automatically indicating with two beeps that the check has been correct The check indicator light will go out PAGE 9 DETECTION OF BAND FAILURE If the communication with a RADIOBAND T fails during checking or the communication is deficient for instance too many communication retries or poor coverage the RADIOBAND R emits three consecutive beeps indicating that an error has occurred Halt the door manoeuvre and press the safety bands installed to detect what has failed single beep is heard on pressing a band this means that the band is correct If three consecutive beeps are heard on pressing the band this means that the band has failed In this event it is recommended changing the orientation of the transmitting receiving aerials or installing an AED 868 or FLAT 868 outdoor aerial to ensure the desired range On exiting check mode seven consecutive beeps will be heard and the indicator light will flash continuously Perform another system check until the result is correct Signal coverage After pressing one of the installed bands continuous flashes ranging from 1 to 5 indicate the signal coverage for this band at the time it was pressed Number of check LED Coverage Result of check Lo Band failure Very good TOTAL RESET In programming mode keep the programming PROG button pressed down and make a bridge with the MR reset jumper for 3s The receiver will emit 10 warning sound signals and
15. secutive beeps are heard on pressing the band this means that the band has failed In this event it is recommended changing the orientation of the transmitting receiving aerials or installing an AED 868 or FLAT 868 outdoor aerial to ensure the desired range On exiting check mode seven consecutive beeps will be heard and the indicator light will flash continuously Perform another system check until the result is correct Signal coverage After pressing one of the installed bands continuous flashes ranging from 1 to 5 indicate the signal coverage for this band at the time it was pressed Number of check LED Coverage Result of check flashes Band failure TOTAL RESET In programming mode keep the programming PROG button pressed down and make a bridge with the MR reset jumper for 3s The receiver will emit 10 warning sound signals and then more at a faster frequency indicating that the operation has been carried out The receiver will stay in programming mode If 10 seconds elapse without programming or if you press the programming button quickly the receiver will go out of programming mode emitting two 15 sound Signals PAGE 16 INSTALLATION ADVICE 868MHz AED 868 or FLAT 868 antenna extension with RG 58 coaxial cable An AED 868 or FLAT 868 antenna extension to 868 MHz should be installed for greater range Install the external antenna and its cable at a place where they are protected against damage and vibrat
16. smitter has to be programmed in one receiver only RADIOBAND T replacement In case you need to replace a RADIOBAND T it is necessary to reset the system see TOTAL RESET on next page and reprogram all RADIOBAND T used in the installation SYSTEM CHECK This function has to be used to check the operation and range of all the devices once the installation has been carried out Press the receivers CHECK button for at least one second to enter check mode The indicator light will come on and four beeps will be heard Perform a complete door opening and closing manoeuvre During the system check a beep will be heard every 1 5 seconds CORRECT OPERATION OF THE SYSTEM If no other acoustic signal is heard on completing the manoeuvre the system 15 operating correctly Either press the CHECK button again or wait 5 minutes and the PAGE 15 RADIOBAND RC RCS will exit checking automatically indicating with two beeps that the check has been correct The check indicator light will go out DETECTION OF BAND FAILURE If the communication with a RADIOBAND T fails during checking or the communication is deficient for instance too many communication retries or poor coverage the RADIOBAND RC RCS emits three consecutive beeps indicating that an error has occurred Halt the door manoeuvre and press the safety bands installed to detect what has failed single beep is heard on pressing a band this means that the band is correct If three con
17. the user Terminals with a maximum section of 3 8mm2 must be used to connect the cables he frequency of the Radioband system does not interfere in any way with the 368 MHz remote control systems However a signal centred at 868 9MHz may cause a delay on the reaction of the system Always connect the door structure and metal parts to an earthing connection Do not share the power and signal supply PAGE 3 2 THE SYSTEM 2 1 RADIOBAND T Conexi n banda de seguridad Connection Barre Palpeuse de Securite Pulsador de programaci n Bouton de programmation Safety band connectionl Programming button Anschluss Sicherheitsleiste Programmschalter 868 90MHz 3V DC 2 x 1 5V LRO3 AAA 12mA 25mW 20 C 55 C P67 85 x 53 x 36mm Range guaranteed 10m Battery life 2 years Minimum time between two 7 min RADIOBAND T activations for complying with the R amp TTE Directive PAGE 4 INSTALLATION AND CONNECTIONS Fix the back of the box to the door Install the transmitter following the technical manual and avoid placing metallic surfaces between the receiver and the transmitter Pass the cables through the bottom of the transmitter Connect a resistive 8K2 safety band directly to terminal B1 and ensure that the safety edge keeps totally waterproof Fix the front of the transmitter to the back with the screws supplied for the purpose N B If a non resistive element with a contact normally closed