1. 8 1 1 Scope 8 1 2 Validity 8 1 3 Cautions and Notes 8 1 4 Spellings 8 2 Safety Instructions 9 3 Description 10 3 1 Application 10 3 2 Access Options 10 3 3 System Overview 11 3 4 Product Range 12 3 5 Accessories 12 3 6 Device Views 14 3 6 1 Draco tera 288 Port 14 3 6 2 Draco tera 160 Port 16 3 6 3 Draco tera 80 Port 17 3 6 4 Draco tera 48 Port 18
2. 198 9 5 Network Error 198 9 6 Failure at the Matrix 199 9 7 Blank Screen 200 10 Technical Support 201 10 1 Support Checklist 201 10 2 Shipping Checklist 201 11 Certificates 202 11 1 CE Declaration Of Conformity 202 11 2 North American Regulatory Compliance 203 11 3 Product Safety 203 11 4 WEEE 204 11 5 RoHS RoHS 2 204 12 Glossary 205 12 1 Matrix specific Glossary 208 Pos 1 806 IHSE Zu diesem Handbuch ATB_Zu diesem Handbuch 5 mod_1278573163276_6 doc 41510 1222 1 Draco tera 8 2013 08 14 1 About This Manual 1 1 Scope This ma
3. 190 7 5 Power Supply 190 Contents 2013 08 14 7 7 6 Environmental Conditions 190 7 7 Size 191 7 8 Shipping Weight 192 7 9 MTBF 193 8 Maintenance 194 8 1 Power Supply Units 194 8 2 Fan trays 194 8 3 CPU Board 195 8 4 I O Board 195 8 5 Filter Pads 196 9 Troubleshooting 197 9 1 External Failure 197 9 2 Video Interference 197 9 3 Malfunction of Fans 198 9 4 Malfunction of Power Supply Units
4. 94 5 5 User Settings 97 5 5 1 User 97 5 5 2 Favorite List Users 100 5 5 3 User Macros 103 5 6 Extender Settings 107 5 6 1 Creating Flex Port Extender Unit 109 5 6 2 Creating Fixed Port Extender Units 110 5 6 3 Deleting Flex Port Extender Units 110 5 6 4 Deleting Fixed Port Extender Units 110 5 7 CPU Settings 111 Contents 2013 08 14 5 5 8 Console Settings 115 5 8 1 CON Devices 115 5 8 2 Mouse and Keyboard 120 5 8 3 Extender OSD 123 5 8 4 Favorite List Consoles 126 5 8 5 Console Macros 128 5 8 6 Parallel Operation 132 5 8 7 Multi Screen Control 135 5 9 Saving and Loadin
5. In order to set a Private Mode connection between a console and a CPU double click on the corresponding selection box within the column Private Mode and select the requested CPU Operation 2013 08 14 167 CPUs whose respective console does not have access rights will not appear in the list The following symbols are shown in the connection overview Symbol Description CON device is connected via Shared Access with at least one further console to the same CPU The CON device has Full Access at the moment CON device is connected via Shared Access with at least one further console to the same CPU The CON device has a Video Access connection at the moment You can use the following button to perform a switching operation Button Function Send Send effected switching operations to the matrix Reset Disconnect all existing connections within the matrix Reload Reload switching status When activating the function Auto Send in the left lower corner of the working area switching operations will be done immediately without confirmation by pressing the button Send When activating the function Hide Devices w o Extender Assignment in the left lower corner of the working area only these CON and CPU devices are shown that are assigned to an extender Draco tera 168 2013 08 14 Possibility 2 Select Status gt Matrix View in the task area Menu Status Matrix View In order to perform switch
6. 3 Select for the highlighted position on the list a macro command in the field Macro Data 4 Set the necessary parameters P1 and P2 e g CON Devices or CPU Devices for the selected macro command 5 Confirm your inputs by pressing the key lt Enter gt and repeat the process for further macro commands if necessary Configuration 2013 08 14 131 Java Tool Select the console in the working area of the menu Definition gt CON Devices for which a macro has to be created and open the tab Macros Menu Definition CON Devices In order to create a macro for the selected console proceed as follows 1 Select in the field Key that one 1 16 for which a macro has to be created 2 Select in the column Function the commands that should be part of the macro The selection list will be opened by a double click on the empty fields 3 Select the respective parameters for the macro functions e g corresponding consoles and CPUs in the columns P1 and P2 4 Confirm your inputs by pressing the button Apply Draco tera 132 2013 08 14 For an efficient macro configuration the following context functions are available When clicking on the tab Macros macros can be assigned to other consoles by using the function Assign Macros to and can be copied from other consoles by using the function Copy Macros from When clicking on the macro list macros of the selected key can be copied into t
7. Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment Shielded cables must be used with this equipment to maintain compliance with radio frequency energy emission regulations and ensure a suitably high level of immunity to electromagnetic disturbances All power supplies are certified to the relevant major international safety standards Pos 173 806 IHSE Zertifikate 474 xx_Produktsicherheit 9 mod_1373964601786_6 doc 77511 2 4 11 3 Product Safety The product safety of the devices is proven by the compliance to the following standards IEC 60950 1A1 2010 EN 60950 1 A12 2011 UL 60950 1 2007 CAN CSA C22 2 60950 1 07 The compliance is verified and confirmed by T V S d Germany Pos 174 806 IHSE Zertifikate ATB_WEEE 5 mod_1278579673292_6 doc 42704 2 1 Draco tera 204 2013 08 14 11 4 WEEE The manufacturer complies with the EU Directive 2012 19 EU on the prevention of waste electrical and electronic equipment WEEE The device labels carry a respective marking Pos 175 806 IHSE Zertifikate ATB_RoHS 5 mod_1278579714214_6 doc 42722 2 1 11 5 RoHS RoHS 2 This device complies with the Directive 2011 65 EU of the European Parliament and of the council of 8 June 2011 on the restriction of the use of certain hazardous substances in electrical and electronic equipment RoHS
8. Working area Lower status area lowest two text lines Configuration 2013 08 14 57 Keyboard control You can select between the following keyboard commands Function Keyboard Command Left cursor only within an input field or a switching screen lt Cursor Left gt Right Cursor only within an input field or a switching screen lt Cursor Right gt In input fields Line up with wrap around In menus Line up without wrap around lt Cursor Up gt In input fields Line down with wrap around In menus Line down without wrap around lt Cursor Down gt Previous page in menus with more than one page lt Page Up gt Next page in menus with more than one page lt Page Down gt Next input field lt Tab gt Previous input field lt Left Shift gt lt Tab gt Next option in selection fields lt gt Previous option in selection fields lt gt Switching in selection fields between two conditions e g between ON OFF or Y Yes N No lt Space gt In menus with input fields Save data In menus Select menu item lt Enter gt In menus with input fields Cancel data input without saving In menus with selection fields Go back to the superior menu lt Esc gt Draco tera 58 2013 08 14 Sorting Function Lists and tables in the Java Tool offer a sorting function for fast and smooth search You have the possibility to
9. 4 3 3 Parallel Operation Stacking 50 4 3 4 Cascading 52 5 Configuration 53 5 1 Command Mode 53 5 2 Control Options 55 5 2 1 Control via OSD 55 5 2 2 Control via Java Tool 60 5 2 3 Control via Serial Interface 69 5 3 Assignment 69 5 3 1 Virtual CPU 69 5 3 2 Virtual Console 72 5 4 System Settings 75 5 4 1 System Data 75 5 4 2 Automatic ID 79 5 4 3 Access 82 5 4 4 Switch 86 5 4 5 Network 90 5 4 6 Date and Time
10. Activate the function Keyboard Connect if taking over control by a keyboard event should be possible 4 Activate the function Mouse Connect if taking over control by a keyboard movement should be possible 5 Define a Release Time of inactivity 0 999 sec after that control can be taken over Draco tera 134 2013 08 14 Java Tool Select System gt Switch in the task area Menu System Switch In order to configure parallel operation proceed as follows 1 Activate the function Enable Video Sharing 2 Activate the function Force Connect 3 Activate the function Keyboard Connect if taking over control by a keyboard event should be possible 4 Activate the function Mouse Connect if taking over control by a keyboard movement should be possible 5 Define a Release Time of inactivity 0 999 sec after that control can be taken over Pos 79 806 IHSE Konfiguration 480_Konsolen Einstellungen 480 xx Multi Screen Kontrolle 8 mod_1360595667772_6 doc 71051 3 1 Configuration 2013 08 14 135 5 8 7 Multi Screen Control In this menu switching of USB HID to control several connected sources computer CPU by a CON device with several monitors can be configured The switching can be performed for up to four connected sources computer CPU and is made smoothly by crossing the mouse pointer beyond the respective monitor to the next one Thereby the monitors can be arranged in sequ
11. Java Tool Select the tab Automatic ID in System gt System Data Menu System Automatic ID Pos 55 806 IHSE zz_Layout Seitenumbruch 8 mod_1348581820516_0 doc 69462 1 Draco tera 82 2013 08 14 Pos 56 806 IHSE Konfiguration Systemeinstellung 480 xx Zugang 7 mod_1309938080446_6 doc 53086 3 1 5 4 3 Access The access configuration is set in this menu You have the following possibilities to access the menu You can select between the following settings Field Selection Description activated The user has to login with a user name and a password once to enter OSD Thereafter the user remains logged in until he explicitly logs out or an auto logout is effected Note When using the function Force User Login console favorites and console macros still remain active Force User Login deactivated Function not active default activated CPU access is restricted according to the permissions in the ACL Access Control List User login is required Switching by keyboard Hot Keys requires a prior login Enable User ACL deactivated Function not active default activated CPU access is restricted according to the permissions in the respective Console ACL Access Control List No login required Enable Console ACL deactivated Function not active default activated Newly created users automatically receive access to all CPUs Enable new User deactivated Fun
12. Java tool Serial interface Pos 7 806 IHSE zz_Layout Seitenumbruch 8 mod_1348581820516_0 doc 69462 1 Description 2013 08 14 11 Pos 8 806 IHSE Beschreibung System bersicht 480 xx 7 mod_1309933171196_6 doc 52495 2 1 4 3 3 3 System Overview A Draco tera matrix system consists of a Draco tera matrix and for KVM applications of one or more CPU Units CON Units The Draco tera matrix is connected to the CPU Units CON Units by interconnect cables or connected directly to the video devices where used as a video matrix The CPU units are connected directly to the sources computer CPU by the provided cables Monitor s keyboard and mouse are connected to the CON units The communication between the Draco tera matrix and the CPU Units CON Units takes place over the respective interconnect cables 1 2 3 5 3 6 4 System Overview exemplary 1 Source computer CPU 2 CPU Units 3 Interconnect cable 4 Draco tera matrix 5 CON Units 6 Console monitor keyboard mouse See Chapter 4 3 Page 47 for installation examples Pos 9 806 IHSE Beschreibung Ger tetypen 480 xx 7 mod_1309934329227_6 doc 52513 2 1 Draco tera 12 2013 08 14 3 4 Product Range Part No Description K480 288 Draco tera matrix with 288 ports empty free configuration K480 160 Draco tera matrix with 160 ports empty free configuration K480 080 Draco tera matrix with 80 port
13. The matrix will be reset to factory settings Pos 116 806 IHSE Betrieb Ein und Ausschaltfunktionen 480 xx 480_Ausschalten 7 mod_1310646450471_6 doc 54300 3 1 6 9 3 Power Down You have the following possibilities to perform a shut down of the system or single components OSD In order to shut down the system proceed as follows 1 Select Configuration gt Shut down Matrix in the main menu 2 Confirm the selection with the button Okay The matrix will be shut down In order to shut down an I O board proceed as followsr 1 Select Configuration gt Shut Down IO Board in the main menu 2 Confirm the selection with the button Okay The I O board will be shut down Pos 117 806 IHSE Betrieb 480_Zusammenfassung Tastaturkommandos 480_Zusammenfassung Tastatur Kommandos 9 mod_1360601486169_6 doc 71092 2 1 Operation 2013 08 14 177 6 10 Summary of Keyboard Commands In the following you find a summary of keyboard commands that can activate extender and matrix functions after executing the Hot Key Extender Keyboard Command Description lt Hot Key gt lt a gt Download of DDC information of the monitor connected to the CON Unit into the CPU Unit lt Hot Key gt lt k gt lt 1 gt lt Enter gt Switch to the KVM connection only with HDMI CON Units with available connection for a local source lt Hot Key gt lt k gt lt 2 gt lt Enter gt Switch to the KVM c
14. IHSE GmbH Maybachstrasse 11 88094 Oberteuringen Germany info ihse de www ihse de Tel 49 7546 9248 0 Fax 49 7546 9248 48 User Manual Edition 2013 08 14 Draco tera Model K480 Series Firmware V02 10 Draco tera 2 2013 08 14 Copyright 2013 All rights reserved This information may not be reproduced in any manner without the prior written consent of the manufacturer Information in this document is subject to change without notice Trademarks All trademark and trade names mentioned in this document are acknowledged to be the property of their respective owners Disclaimer While every precaution has been taken during preparation of this manual the manufacturer assumes no liability for errors or omissions Neither does the manufacturer assume any liability for damages resulting from the use of the information contained herein The manufacturer reserves the right to change specifications functions or circuitry of the product without notice The manufacturer cannot accept liability for damage due to misuse of the product or due to any other circumstances outside the manufacturer s control whether environmental or installation related The manufacturer shall not be liable for any loss damage or injury arising directly indirectly incidentally or consequently from the use of this product Contents 2013 08 14 3 Contents 1 About This Manual
15. It allows a data exchange via monitor cable and an automatic installation and configuration of a monitor driver by the operating system Dual Access A system to operate a source computer CPU from two consoles Dual Link A DVI D interface for resolutions up to 2560x2048 by signal transmission of up to 330 MPixel s 24 bit Dual Head A system with two video connections Draco tera 206 2013 08 14 Term Explanation DVI Digital video standard introduced by the Digital Display Working Group http www ddwg org Single Link and Dual Link standard are distinguished The signals have TMDS level DVI I A combined signal digital and analog that allows running a VGA monitor at a DVI I port in contrast to DVI D see DVI EGA The Enhanced Graphics Adapter EGA is an old analog graphic standard introduced by IBM in 1984 A D Sub 9 connector is used for connection Fiber Single mode or multi mode fiber cables HDMI An interface for an all digital transmission of audio and video data It is differentiated between the HDMI standards 1 0 to 1 4a The signals have TMDS level KVM Keyboard video and mouse Mini XLR Industrial standard for electrical plug connections 3 pole for the transmission of digital audio and control signals Multi mode 62 5 multi mode fiber cable or 50 multi mode fiber cable OSD The On Screen Display is used to display information or to operate a device Quad Head A system wi
16. Report The Java tool is equipped with a report function that shows the current switching status and all relevant parts of the matrix configuration in a PDF file In order to create a report proceed as follows 1 Select File gt Report in the menu bar A selection assistant will be opened 2 Select those contents that should be included in the report Matrix View EXT Units CPU Devices CON Devices and Users and confirm with the button Next gt 3 Select the preferred location for storage of the report and confirm with the button Finish The report will be created as a PDF file Menu File gt Report The report function can be used in both online or offline mode of the Java tool Pos 47 806 IHSE Konfiguration 480_Ansteuerung 480 xx Ansteuerung via serieller Schnittstelle 7 mod_1309937747180_6 doc 52956 3 1 Configuration 2013 08 14 69 5 2 3 Control via Serial Interface The Draco tera operating system offers various functions for an operation via serial interface There are telegrams for Switching single or all connections available both unidirectional and bidirectional In addition to that there are telegrams for an overall definition of the total switching status and for saving and loading such switching states By request the Draco tera optionally provides an echo of all effected switching operations via serial interface or network interface That is why you have the possibility to track
17. SWITCH_01 Name Text Enter the name of the configuration that is used to save the current settings default Standard Info Text Additional text field to describe the configuration default Factory settings activated If the matrix is defined as a sub matrix in the OSD the user will loose control automatically Control can be recovered by using the keyboard command lt Shift gt lt Shift gt lt s gt lt o gt The OSD now will be opened again in the matrix that has been defined as sub matrix Sub Matrix deactivated Function not active default activated Starting the matrix after a restart or a switch on with the default configuration Load Default deactivated Starting the matrix after a restart or a switch on with the last saved configuration default Draco tera 76 2013 08 14 Field Selection Description activated Save the current configuration of the matrix in the flash memory periodically Note During saving of the configuration the matrix will not be operational Saving takes place every 600 seconds as long as changes of the configuration or switching operations have been executed in the meantime Auto Save deactivated Function not active default activated Send all performed switching commands in the matrix as an echo via serial interface Note This function should be enabled when using a media control via serial interface Enable COM Echo deactivated Function not active
18. The filter function is based on the functional principle of common web search engines Offline Configuration Configuration and system settings via Java Tool can be changed in offline mode without a direct connection between matrix and Java Tool In order to activate a configuration in the matrix proceed as follows 1 Select File gt Upload in the menu bar 2 Enter the IP address of the matrix see Chapter 5 2 3 Page 69 and the name and password of the user authorization and select the storage location of the new configuration default or config01 08 in the menu Select Configuration 3 Select Matrix gt Connect in the menu bar and enter the IP address of the matrix and the name and password for user authorization 4 Select Administration gt Activate Configuration in the task area and select the storage location that has been selected above 5 Use the button Activate to open the selected configuration within the matrix The connection and the open tab will be closed and the matrix will be restarted During the activation of a configuration the matrix is temporarily not available Draco tera 66 2013 08 14 Online Configuration Configurations and system settings can be also edited via Java tool in online mode with an active connection between matrix and Java tool Menu System System Data In order to edit a configuration in online mode proceed as follows 1 Select the menu item Matrix g
19. Tie Line Communication connection to and between extension modules in a network environment User ACL User Access Control List is a list that shows the respective switching rights for the various users Video Sharing Matrix function that allows switching from the own console to any CPU with video Ende der Liste f r Textmarke Inhalt
20. activated If a console is not connected to a CPU you can establish an automatic connection to the next available CPU by hitting any key or mouse button CPU Auto Connect deactivated Function not active default CPU Timeout 0 999 minutes Period of inactivity after which a console will be automatically disconnected from its current CPU default value 0 minutes activated Activate request of K M control by keyboard event key will be lost Keyboard Connect deactivated Function not active default activated Activate request of K M control by mouse event Mouse Connect deactivated Function not active default Release Time 0 999 seconds Period of inactivity of a connected console after which K M control can be requested by other consoles connected to the CPU Note Set 0 for an immediate transfer in real time Only one console can have keyboard and mouse control at the same time The other consoles that are connected to the same CPU have a video only status default value 10 seconds If the options Keyboard Connect and or Mouse Connect are activated the condition Release Time will have to be met until a new user will gain control Draco tera 88 2013 08 14 OSD Select Configuration gt Switch in the main menu Menu Configuration Switch You can select between the following buttons Button Function Cancel Reject changes Save Save changes Configura
21. default activated Send all performed switching commands in the matrix as an echo via LAN connection Note This function should be enabled when using a media control via LAN connection or when using stacking with two ore more matrices Enable LAN Echo deactivated Function not active default activated Synchronize the slave matrix according to the switch status of the master matrix Slave Matrix deactivated Function not active default Master IP Address Numerical value Set the network address of the master matrix default value 000 000 000 000 activated Keep I O boards with wrong or invalid firmware online in the matrix Ivalid IO Boards deactivated Shut down I O boards with wrong or invalid firmware automatically default Hor Mouse Speed 1 x 1 9 Adjustment of the horizontal mouse speed 1 slow 9 fast default value 4 Ver Mouse Speed 1 x 1 9 Adjustment of the vertical mouse speed 1 slow 9 fast default value 5 Double Click Time 100 800 Adjustment of the time slot for a double click default value 200 ms Keyboard layout Region Set the OSD keyboard layout according to the used keyboard default German DE Configuration 2013 08 14 77 OSD Select Configuration gt System in the main menu Menu Configuration System You can select between the following buttons Button Function Cancel Reject changes Save Save changes Draco tera 78
22. 2013 08 14 Java Tool Menu System System Data Pos 53 806 IHSE zz_Layout Seitenumbruch 8 mod_1348581820516_0 doc 69462 1 Configuration 2013 08 14 79 Pos 54 806 IHSE Konfiguration Systemeinstellung 480 xx Automatic ID 7 mod_1309938041118_6 doc 53068 3 1 5 4 2 Automatic ID The settings for the automatic creation of CPU and CON devices by connecting a new extender unit are made in this menu You have the following possibilities to access the menu You can select between the following settings Field Selection Description activated Automatic creation of a new CPU or CON device if new extender units are connected default Enable Auto Config deactivated Function not active ID Real CPU Device Numerical value Initial value of the automatic ID for real CPUs default value 1000 ID Virtual CPU Device Numerical value Initial value of the automatic ID for virtual CPUs default value 2000 ID Real CON Device Numerical value Initial value of the automatic ID for real CONs default value 3000 ID Virtual CON Device Numerical value Initial value of the automatic ID for virtual CONs default value 4000 Draco tera 80 2013 08 14 OSD Select Configuration gt System in the main menu Menu Configuration System You can select between the following buttons Button Function Cancel Reject changes Save Save changes Configuration 2013 08 14 81
23. 3 7 Diagnostics and Status 19 3 7 1 Status LEDs 19 3 7 2 Port Status 26 3 7 3 Extender OSD 30 3 7 4 Network Status 31 3 7 5 Firmware Status Matrix 34 3 7 6 Firmware Status Extender 36 3 8 Trace Function 37 3 9 Syslog Monitoring 38 3 10 SNMP 40 3 11 System Check 44 4 Installation 46 4 1 Package Contents 46 Draco tera 4 2013 08 14 4 2 System Setup 46 4 3 Example Applications 47 4 3 1 KVM Matrix 48 4 3 2 Video Matrix 49
24. 5 Draco tera matrix slave matrix 6 Network connection master slave s 7 CON unit 8 Console 2x monitor keyboard mouse Pos 41 806 IHSE Installation Installationsbeispiele 480 xx Kaskadierung 7 mod_1309936471961_6 doc 52864 3 1 Draco tera 52 2013 08 14 4 3 4 Cascading For applications exceeding the number of available ports the system can be extended by cascading In this case the Draco tera devices are connected by so called tie lines The tie lines are dynamically configured to support connections in both directions To access cascaded matrices from a console one of the matrices has to be configured as sub matrix see Chapter 5 4 1 Page 75 1 2 3 3 4 6 3 7 5 Cascading 1 Source computer CPU 2 CPU unit 3 Interconnect cable 4 Draco tera sub matrix 5 Draco tera main matrix 6 CON unit 7 Console monitor keyboard mouse Pos 42 806 IHSE Konfiguration UEB_Konfiguration 5 mod_1278575517073_6 doc 41846 1 1 Configuration 2013 08 14 53 5 Configuration Pos 43 806 IHSE Konfiguration Kommando Modus 480 xx 7 mod_1309936855602_6 doc 52882 2 1 5 1 Command Mode The Draco tera has a Command Mode that allows several functions via keyboard command during normal use To enter Command Mode use a Hot Key sequence and to exit Command Mode press lt Esc gt While in Command Mode the LEDs Shift and Scroll on the console keyboard will fl
25. 568 B Four pairs of wires AWG26 8 Connection according to EIA TIA 568 B 1000BASE T The use of flexible cables patch cables type AWG26 8 is possible however the maximum possible extension distance is halved Pos 129 806 IHSE Technische Daten Verbindungskabel Verbindungskabel Cat X _Kabell nge 477 xx 5 mod_1278937761105_6 doc 43167 1 Draco tera 182 2013 08 14 Maximum Acceptable Cable Length Cat X Installation Cable AWG24 140 m 400 ft Cat X Patch Cable AWG26 8 70 m 200 ft Pos 130 806 IHSE Technische Daten Verbindungskabel 480 xx Glasfaser 7 mod_1309942335305_6 doc 53729 3 1 7 2 2 Fiber A point to point connection is necessary Operation with multiple patch panels is allowed Routing over active network components such as Ethernet Hubs Matrixes or Routers is not allowed Type of Interconnect Cable Cable notations according to VDE Type of cable Specifications Single mode 9 m Two fibers 9 m I V ZN H 2E9 in house patch cable I V ZN HH 2E9 in house breakout cable I AD ZN H 4E9 in house or outdoor breakout cable resistant A DQ ZN B2Y 4G9 outdoor cable with protection against rodents Multi mode 50 m Two fibers 50 m I V ZN H 2G50 in house patch cable I AD ZN H 4G50 in house or outdoor breakout cable resistant Multi mode 62 5 m Two fibers 62 5 m I V ZN HH 2G62 5 in house breakout cable A DQ Z
26. 7 4 2 I O Port Cat X Pos 145 806 IHSE Technische Daten Pinbelegungen RJ45 5 mod_1278578820011_6 doc 42405 1 RJ45 Picture Pin Signal Pin Signal 1 D1 5 D3 2 D1 6 D2 3 D2 7 D4 8 1 4 D3 8 D4 Pos 146 806 IHSE Technische Daten Pinbelegungen UEB_E A Port SFP 7 mod_1309943436008_6 doc 53894 3 1 7 4 3 I O Port SFP Pos 147 806 IHSE Technische Daten Pinbelegungen Glasfaser SFP Typ LC 5 mod_1278938501151_6 doc 43210 1 Fiber SFP Typ LC Picture Diode Signal 1 Data OUT 1 2 2 Data IN Pos 148 806 IHSE Technische Daten Pinbelegungen UEB_E A Port SDI 7 mod_1309943510165_6 doc 53912 3 1 Draco tera 190 2013 08 14 7 4 4 I O Port SDI Pos 149 806 IHSE Technische Daten Pinbelegungen Mini BNC SDI 7 mod_1309943545633_6 doc 53930 1 Mini BNC SDI Picture Pin Signal 1 Data IN 1 2 2 GND Pos 150 806 IHSE Technische Daten Stromversorgung 480 xx 7 mod_1309943583946_6 doc 53948 2 1 7 5 Power Supply Nominal Current Nominal Voltage Draco tera 288 12 A 100 240 Vac 50 60 Hz Draco tera 160 9 A 100 240 Vac 50 60 Hz Draco tera 80 48 5 A 100 240 Vac 50 60 Hz Power Requirement Draco tera 288 max 202 W without I O boards Draco tera 160 max 188 W without I O boards Draco tera 80 max 99 W without I O boards Draco tera 48 max 94 W without I O boards I O Board max 13 W Pos
27. Creating Fixed Port Extender Units In order to create a fixed port extender unit e g USB 2 0 proceed as follows 1 Press the button New 2 Select if a template of a USB 2 0 CON unit USB CON Unit or USB 2 0 CPU unit USB CPU Unit should be used 3 Press the button OK 4 Determine a port at the matrix that should be used with the USB 2 0 extender unit Fixed Port As an option the name of the USB 2 0 extender unit can be changed Name 5 Press the button Apply to save the new extender unit Created extender units are always set as fixed port extenders These configurations are necessary if you want to switch e g USB 2 0 connections via the matrix 5 6 3 Deleting Flex Port Extender Units Deleting Flex Port extender units connected to the matrix is not possible 5 6 4 Deleting Fixed Port Extender Units In order to delete a fixed port extender unit e g USB 2 0 proceed as follows 1 Verify that the fixed port extender unit to be deleted is currently not assigned to a device 2 Select the fixed port extender unit to be deleted in the selection list on the left side of the menu EXT Units and confirm with the key lt Enter gt 3 Press the button Delete 4 Confirm the delete process with the button Okay In order to make a fixed port available again for Flex Port extender units after deleting a fixed port extender unit a restart of the I O board is obligatory Pos 67 806 IHS
28. Ctrl gt at the same time more than one CPU device can be marked 2 Press the button gt to move the marked CPU devices to the favorite list If you press the button gt gt the first eight CPU devices from the list CPU available will be moved to the favorite list CPU assigned 3 The order of marked CPU devices within the favorite list can be changed by pressing the keys lt gt and lt gt 4 To remove marked CPU devices from the favorite list press the button lt If you press the button lt lt all CPU devices will be removed from the favorite list Pos 77 806 IHSE Konfiguration 480_Konsolen Einstellungen 480 xx Konsolen Makros 7 mod_1330939768963_6 doc 57900 3 1 5 8 5 Console Macros In this menu macro commands for switching disconnection or user administration can be created The macro commands are created for each console separately A macro can execute up to 16 switching commands successively The execution of the macros is done via Hot Key and the function keys lt F1 gt lt F16 gt see Chapter 6 1 3 Page 159 You can select between the following settings Field Selection Description Connect P1 CON P2 CPU Set bidirectional connection from console P1 to CPU P2 Connect Video P1 CON P2 CPU Set video connection from console P1 to CPU P2 Disconnect P1 CON Disconnect console P1 Logout User Logout current user Function 01 16 Set Real CPU P1 VCPU P2
29. D S data 2 9 T M D S data 1 17 T M D S data 0 2 T M D S data 2 10 T M D S data 1 18 T M D S data 0 3 T M D S data 2 GND 11 T M D S data 1 GND 19 T M D S data 0 GND 4 n c 12 n c 20 n c 5 n c 13 n c 21 n c 6 DDC Input SCL 14 5VDC high impedance 22 T M D S clock GND 7 DDC Output SDA 15 GND 23 T M D S clock 8 Internal use 16 Hot Plug recognition 24 T M D S clock C1 Internal use C3 Internal use C2 n c C5 GND C4 Internal use Pos 141 806 IHSE Technische Daten Pinbelegungen Buchse USB Typ A 5 mod_1278578771214_6 doc 42369 1 Connector USB Type A Picture Pin Signal Color 1 VCC 5VDC Red 2 Data White 3 Data Green 1 3 2 4 4 GND Black Pos 142 806 IHSE Technische Daten Pinbelegungen D Sub 9 Seriell 5 mod_1291128631437_6 doc 44882 1 Specifications 2013 08 14 189 D Sub 9 Serial RS232 Picture Pin Signal Pin Signal 1 n c 6 DSR 2 RxD 7 RTS 3 TxD 8 CTS 4 DTR 9 n c 1 5 6 9 5 GND Pos 143 806 IHSE Technische Daten Pinbelegungen 480 xx RJ45 7 mod_1309943226649_6 doc 53857 1 RJ45 Picture Pin Signal Pin Signal 1 D1 5 n c 2 D1 6 D2 3 D2 7 n c 8 1 4 n c 8 n c Pos 144 806 IHSE Technische Daten Pinbelegungen UEB_E A Port Cat X 7 mod_1309943361243_6 doc 53876 3 1
30. Description 2013 08 14 27 Menu Status Matrix View example 2 The colors indicate the connection status Color Description Grey Port not connected Yellow Video connection Green KVM connection Red Faulty Port Draco tera 28 2013 08 14 The symbol indicates the extender that is recognized and defined at a certain port Symbol Description Port connected to a CPU Unit Port is connected to a CPU Unit that is switched to a CON Unit in Private Mode see Chapter 3 7 3 Page 30 Port connected to a CON Unit Port connected to a CON Unit with Shared Access to a CPU Port is connected to a CON Unit that is connected to a CPU Unit in Private Mode see Chapter 3 7 3 Page 30 Port connected to an USB 2 0 CPU Unit Port connected to an USB 2 0 CON Unit Port is configured as a CON port for customer specific applications Port is configured as a CPU port for customer specifiv applications Red framed ports are defined as fixed e g for USB 2 0 connections The port with four static blue squares is currently selected If a port is selected all the other ports will be shown transparently except of those that are connected to the currently selected port A selection can be cleared by pressing the button Clear Selection If there is shown a red cross on a port when switching via Matrix View the console to be connected does not have access rights to the respecting CPU
31. Down Functions Pos 113 806 IHSE Betrieb Ein und Ausschaltfunktionen 480 xx Neustart 7 mod_1309941015165_6 doc 53620 3 1 6 9 1 Restart You have the following possibilities to perform a restart OSD 1 Select Configuration gt Restart Matrix or Restart IO Board in the main menu to restart either the matrix or the I O boards 2 Confirm the selection with button Okay The matrix and the I O boards will be restarted with the current settings Java Tool Select Matrix gt Restart Matrix in the menu bar The matrix will be restarted with the current settings The boot process of the matrix might take longer if there is no physical network connection available Pos 114 806 IHSE zz_Layout Seitenumbruch 8 mod_1348581820516_0 doc 69462 1 Draco tera 176 2013 08 14 Pos 115 806 IHSE Betrieb Ein und Ausschaltfunktionen 480 xx Factory Reset 7 mod_1309941081774_6 doc 53638 3 1 6 9 2 Factory Reset You have the following possibilities to perform a reset of the system If you do a factory reset all current settings and all configurations stored in the matrix will be lost This also applies to the network parameters reset to DHCP and the admin password If a firmware update has been done since the delivery the matrix will be set to the state defined there OSD 1 Select Configuration gt Factory Reset in the main menu 2 Confirm the selection with the button Okay
32. Enter a name or the new switch macro and confirm by pressing the button Ok in the save dialog 5 By clicking on a selected switch macro with the right mouse button you can create a copy of the current switch macro when using the option Save as 6 Already saved macros can be deleted by pressing the symbol Delete To load a predefined switching proceed as follows 1 Select the switch macro in the right column of the working area that has to be loaded 2 Activate the selected switch macro by pressing the button Send on the bottom right of the working area A predefined switch macro can only be activated in online mode When loading presets only these switching operations are taken into account that are compliant with the hardware and the configuration of the currently used matrix Pos 110 806 IHSE Betrieb Serielle Schnittstellen 480 xx 7 mod_1309940914961_6 doc 53582 2 1 6 8 Serial Interface The Draco tera offers the possibility to switch via a serial interface RS232 Detailed information for the serial interface and the corresponding switching commands are available in form of an API application programming interface upon request Pos 111 806 IHSE zz_Layout Seitenumbruch 8 mod_1348581820516_0 doc 69462 1 Operation 2013 08 14 175 Pos 112 806 IHSE Betrieb Ein und Ausschaltfunktionen UEB_Ein _und_Ausschaltfunktionen 7 mod_1309940964258_6 doc 53601 2 1 6 9 Power On and Power
33. ID Text ID of the CON unit see Chapter 5 4 2 Page 79 Name Text Name of the CON device activated Create new CON device as a virtual one Virtual Device deactivated Function not active default activated Allow activation of the User ACL at the local console Allow User ACL deactivated Function not active default activated Force user login at this CON device Force Login deactivated Function not active default activated When losing the video signal between source computer CPU and the CPU unit or when losing the connection between the matrix and the CON unit there will be displayed an orange frame When switching to a CPU without video signal a blank screen will appear surrounded by an orange frame LOS Frame deactivated Function not active default Draco tera 116 2013 08 14 Field Selection Description activated Allow a scan mode with an automatic change of the video signal for the favorite list CPU devices of the respective console or a logged in user Allow CPU Scan deactivated Function not active default activated Force a scan mode with an automatic change of the video signal for the favorite list CPU devices of the respective console or a logged in user Force CPU Scan deactivated Function not active default Scan Time 0 99 seconds Retention period until switching to the next CPU device Configuration 2013 08 14 117
34. Switching 161 6 3 Extended Switching 164 6 4 CON Switch 169 6 5 Multi Screen Control 171 6 6 USB 2 0 Switching 172 Draco tera 6 2013 08 14 6 7 Presets 173 6 8 Serial Interface 174 6 9 Power On and Power Down Functions 175 6 9 1 Restart 175 6 9 2 Factory Reset 176 6 9 3 Power Down 176 6 10 Summary of Keyboard Commands 177 7 Specifications 179 7 1 Interfaces 179 7 1 1 DVI D Single Link 179 7 1 2 USB HID 179 7 1 3 RJ45 Network 180 7 1 4 RS 23
35. The pollution of the filter pads has to be checked regularly and the pads have to be cleaned with slight compressed air or suction by the operator of the system The inspection cycle depends on the ambient air and cannot be determined generally A period of 6 months should not be exceeded A replacement of the filter pads or the filter trays has to be performed every year In order to replace a filter pad proceed as follows 1 Pull the filter pad together with the mounting frame out of the proper slot by using the handle 2 Press the used filter pad out of the mounting frame 3 Insert a new filter pad into the mounting frame 4 Put the mounting frame back into the slot again Pos 158 806 IHSE Hilfe im Problemfall UEB_Hilfe im Problemfall 5 mod_1278579113839_6 doc 42536 1 1 Troubleshooting 2013 08 14 197 9 Troubleshooting Pos 159 806 IHSE Hilfe im Problemfall Hilfe im Problemfall 480 xx 7 mod_1309943852774_6 doc 54002 1 In the following chapters support for problems with the Draco tera matrix is provided This help is based on a working point to point extender connection concerning the contents Please ensure before running your extenders with the matrix that they work over a peer to peer connection This can be supported by the use of a Cat X or fiber coupler If you have problems referring to this the manuals of the respective extenders will offer support Pos 160 806 IHSE Hilfe im P
36. Y Yes or N No IP Address Information about the IP address as provided manually or via DHCP Subnet Mask Information about the subnet mask as provided manually or via DHCP Gateway Information about the gateway address as provided manually or via DHCP MAC ID Information about the MAC address of the matrix Draco tera 32 2013 08 14 OSD Select Status gt Network in the main menu Menu Status Network Description 2013 08 14 33 Java Tool 1 Select Status gt Matrix View in the task area Menu Status Matrix View 2 Use the left mouse button to click on the network port of the CPU board The corresponding network status will be shown in the right part of the working area Pos 27 806 IHSE Beschreibung Status Firmware Status 480 xx 7 mod_1309935560836_6 doc 52699 33 1 Draco tera 34 2013 08 14 3 7 5 Firmware Status Matrix The current firmware status of the installed boards is shown in this menu You have the following possibilities to access the menu The following information is shown in this menu Field Description Name Description of the modules Type Type number Ports Number of ports Version Complete description of the firmware version Date Date of the firmware version Status Module status OSD Select Status gt Firmware in the main menu Menu Status Firmware Description 2013 08 14 35 Java Tool 1 Select Statu
37. area 4 Quit Service Mode after updating upon request in the popup window or via Matrix gt Deactivate Service Mode in the task area 5 Verify after the update in the Java tool via Administration gt Update EXT Firmware in the tab Protocol of the Expert Mode if the updates for all extenders have been installed correctly Pos 92 806 IHSE Konfiguration 480_Lizenzmanagement 480 xx 8 mod_1352795644169_6 doc 69622 2 4 5 12 License Management In this menu the matrix can be upgraded with new function bundles by using license keys In order to get license keys to upgrade matrix functions contact your distributor You have the following possibility to access the menu Configuration 2013 08 14 155 Java Tool In order to activate a function bundle proceed as follows 1 Select Administration gt License Management in the task area Menu Administration License Management 2 Enter your license key in the working area under Activate Bundles in the field License Key 3 In order to activate the license key press the button Activate The new functions will be immediately enabled a restart of the matrix will not be necessary Pos 93 806 IHSE Betrieb UEB_Betrieb 5 mod_1278577614980_6 doc 41970 1 1 Draco tera 156 2013 08 14 6 Operation Pos 94 806 IHSE Betrieb 480 xx 7 mod_1309939496086_6 doc 53444 1 The Draco tera can be operated in three different ways 1 Direct S
38. be removed and exchanged during operation The following exchangeable components can be found within the Draco tera 8 1 Power Supply Units In order to exchange the power supply units proceed as follows 1 Make sure that the power cord cable is removed from the power supply that has to be exchanged 2 Unlock the locking screw s 3 With the power supply units of Draco tera 288 and 160 turn the unlocked bracket down 4 Pull the power supply unit out of the corresponding slot 5 Push a new or maintained power supply unit into the slot and lock it accordingly 6 Connect the power cord cable to the power supply unit It will be recognized by the system and can be used afterwards 8 2 Fan trays In order to exchange the fan trays proceed as follows 1 Unlock the locking screw s 2 Pull the fan tray out of the corresponding slot by using the provided mount 3 Push a new or maintained fan tray into the slot 4 Lock the fan tray accordingly It will be recognized by the system and can be used afterwards Maintenance 2013 08 14 195 8 3 CPU Board In order to exchange the CPU board proceed as follows 1 Pull the locking pin slowly out of the CPU board up to the stop Wait until the CPU board will be deregistered from the matrix The de registration will be confirmed by a permanent green light of the status LED 1 at the CPU board see Chapter 3 7 1 Page 19 2 Remove all cabl
39. by pressing the button Apply For an efficient macro configuration the following context functions are available Via right click on the tab Macros macros can be assigned to other users by using the function Assign Macros to and can be copied from other users by using the function Copy Macros from Configuration 2013 08 14 107 Via right click on the macro list macros of the selected key can be copied into the cache by using the function Copy Key Macros You can paste the macros from the cache into a key by using the function Paste Key Macros and you can reset all macros of the selected key by using the function Reset Key Macros Pos 66 806 IHSE Konfiguration 480_Extender Einstellungen 480 xx 7 mod_1309938366618_6 doc 53197 23333 1 5 6 Extender Settings All extender units are managed in this menu This also contains the creation of new extender units and the deletion of existing extender units The extender unit describes the connection of an physical extender to the matrix Every extender board with a direct cable connection to the matrix is recognized as an extender unit Dual Head KVM extenders will be recognized as two independent extender units KVM Extenders automatically create extender units inside the matrix You have the following possibilities to access the menu You can select between the following settings Field Selection Description ID Text Numerical value of the extender I
40. kg 69 9 lb Draco tera 80 Matrix 11 1 kg 24 5 lb fully equipped Shipping Box 15 6 kg 34 4 lb Draco tera 48 Matrix 8 9 kg 19 6 lb fully equipped Shipping Box 12 1 kg 26 7 lb Pos 156 806 IHSE Technische Daten MTBF 480_MTBF 9 mod_1375173854011_6 doc 79261 2 4 Specifications 2013 08 14 193 7 9 MTBF The following table contains the mean time between failure MTBF in power on hours POH The estimate is based on the FIT rates of the parts included FIT rates are based on normalized environmental conditions of T 60 C and activation energy Ea of 0 7 eV Calculations are based on 90 confidence limit We estimate that inside the housing temperature will be 15 C higher than the ambient temperature Therefore the MTBF calculation refers to an ambient temperature of 45 C The humidity is limited to 60 Draco tera 288 chassis 260 000 POH Draco tera 160 chassis 310 000 POH Draco tera 80 chassis 320 000 POH Draco tera 48 chassis 350 000 POH CPU board 480 000 POH I O board SFP 500 000 POH I O board Cat X 410 000 POH Draco tera 288 160 PSU 200 000 POH Draco tera 80 48 PSU 130 000 POH Pos 157 806 IHSE Wartung 480 xx_Wartung 8 mod_1351506868807_6 doc 69520 122222 4 Draco tera 194 2013 08 14 8 Maintenance The Draco tera contains various components and assemblies that can be maintained All relevant components and assemblies are hot swappable and can
41. mini BNC connectors or 3G SFPs with transmission speeds of 0 360 Gbit s SD SDI SMPTE 259M 1 485 Gbit s HD SDI SMPTE 292M and 2 970 Gbit s 3G SDI Pos 127 806 IHSE Technische Daten Verbindungskabel UEB_Verbindungskabel 5 mod_1279191107845_6 doc 43870 2 1 7 2 Interconnect Cable Pos 128 806 IHSE Technische Daten Verbindungskabel Verbindungskabel Cat X 5 mod_1278578406026_6 doc 42205 3 1 7 2 1 Cat X A point to point connection is required Operation with several patch fields is possible Routing over an active network component such as an Ethernet Hub Router or Matrix is not allowed Avoid routing Cat X cables along power cables If the site has 3 phase AC power try to ensure that CPU Unit and CON Unit are on the same phase To maintain regulatory EMC compliance correctly installed shielded Cat X cable must be used throughout the interconnection link To maintain regulatory EMC compliance all Cat X cables need to carry ferrites on both cable ends close to the device Type of Interconnect Cable The Draco tera requires interconnect cabling specified for Gigabit Ethernet 1000BASE T The use of solid core AWG24 shielded Cat 5e or better is recommended Cat X Solid Core Cable AWG24 S UTP Cat 5e cable according to EIA TIA 568 B Four pairs of wires AWG24 Connection according to EIA TIA 568 B 1000BASE T Cat X Patch Cable AWG26 8 S UTP Cat 5e cable according to EIA TIA
42. position of the extender OSD By pressing the key lt F8 gt inactive CPU Devices can be hidden to ensure a better overview 3 Execute the desired switching operation by pressing the respective key see Chapter 6 3 Page 164 In order to not execute a switching operation and access OSD press the key lt F7 gt In order to close the selection list press the key lt Esc gt Operation 2013 08 14 163 Example view Selection list CPU Devices Activating the automatical Scan Mode for CPU Devices The matrix offers the possibility to use a scan mode based on the favorite list of each console or user The scan mode allows the matrix to switch in sequence between the CPU Devices in the favorite list within a predefined time All scans are performed in video only mode For a configuration of the scan mode Chapter 5 8 1 Page 115 You have the following possibility to activate the scan mode In order to activate the scan mode proceed as follows 1 Define a favorite list for the respective CON Device or user see Chapter 5 8 4 Page 126 for CON Devices or see Chapter 5 5 2 Page 100 for users 2 Start Command Mode with the Hot Key and press lt o gt to open OSD 3 Select in the CPU selection list one of the CPU Devices that are defined in your favorite list Draco tera 164 2013 08 14 4 Confirm your selection by pressing the button CPU Scanner The scan will automatically start 5 If you have enabled
43. proceed as follows 1 Set the option SNTP Client to Y Yes 2 Enter the IP address of your SNTP server in the field SNTP Server 3 Select your time zone in the field Time Zone 4 Press the button Okay to confirm your settings 5 Restart the matrix The system time will be now provided by the SNTP server In order to set the real time clock without using SNTP proceed as follows 1 Set the current date in the field Date 2 Set the current Day in the field Day 3 Set the current time in the field Time 4 Press the button RTC to confirm your settings Draco tera 96 2013 08 14 Java Select System gt Date and Time in the main menu Menu Configuration Date and Time In order to configure a time server proceed as follows 1 Enable option SNTP 2 Enter the IP address of your SNTP server in the field SNTP Server 3 Select your time zone in the field Time Zone 4 Press the button Apply to confirm your settings 5 Restart the matrix The system time will be now provided by the SNTP server In order to set the real time clock without using SNTP proceed as follows 1 Set the current date in the field Date and Time 2 Set the current time in the field Day and Time 3 Press the button Apply to set the system time 4 Option If you want to receive the time from your currently used computer press the button Get Local Time Pos 61 806 IHSE zz_Layout Seitenu
44. standard with a typical resolution of 640x480 pixels and up to 262 144 colors It can be seen as a follower of the graphics standards MDA CGA and EGA Pos 177 806 IHSE zz_Layout Seitenumbruch 8 mod_1348581820516_0 doc 69462 1 Draco tera 208 2013 08 14 Pos 178 806 IHSE Glossar 480 xx 7 mod_1309944815290_6 doc 54151 2 1 12 1 Matrix specific Glossary Term Explanation Auto Disconnect Matrix function that allows an automatic disconnect between a console and a CPU if OSD is opened via this console Auto Logout Matrix function that describes the duration of inactivity after the user has been logged out from the OSD at this console CON Device Logical term that summarizes several physical extenders to switch more complex console systems via matrix CON Timeout Matrix function that allows an automatic disconnect of the own console from the connected CPU after a predefined time Console ACL Console Access Control List is a list that shows the respective switching rights for the various consoles CPU Auto Connect Matrix function that allows an automatic connection establishment between the own console and a random CPU that is available CPU Device Logical term that summarizes several physical extenders to switch more complex CPU systems via matrix CPU Timeout Matrix function that allows the user to disconnect after a predefined period of time of inactivity from the respective CPU EXT Uni
45. the option Force CPU Scan the scan will automatically start after switching the respective CON Device to any CPU Device from the favorite list without the need to press the button CPU Scanner 6 3 Extended Switching You have the following possibilities to perform switching operation with the Draco tera OSD To switch any console to any available CPU proceed as follows Select Extended Switch in the main menu By pressing the key lt F8 gt inactive CPU Devices can be hidden to ensure a better overview Menu Extended Switch Operation 2013 08 14 165 1 Select in the list CON Devices on the left side that one that should be switched to a CPU device and open it by pressing lt Enter gt 2 Select in the list CPU Devices on the left side that one that should be connected to the open CON device 3 Confirm with the respective keyboard command according to the desired connection type Switching operations from the own CON device can only be done to CPU devices that are available in the list CPU Devices The following information is shown in this menu Field Description CON device Assigned physical extender unit CON unit CON assigned Virtual CON Device that is assigned to the real CON device CPU connected Currently connected CPU device CON status Current connection status CON device EXT list List of all available physical extender units CON units CPU device Assigned physical exten
46. this option the permission for an active query of the SNMP agent is granted In order to configure a SNMP server proceed as follows 1 Select Configuration gt SNMP in the main menu 2 Set the option Enable Traps to Y Yes within SNMP Server This function allows an active transmission of trap messages from the SNMP agent to the SNMP server 3 Set the IP address of the SNMP server within Server Address 4 Activate the requested traps by enabling them to Y Yes Draco tera 42 2013 08 14 You can select between the following traps Trap Description Status Notification about the matrix status Temperature Notification about the temperature within the matrix Insert Board Notification about the insertion of a new I O board into a slot Remove Board Notification about the removal of an I O board out of a slot Invalid Board Notification about a non properly working I O board Insert Extender Notification about a newly connected extender to the matrix notification about a switched on extender notification about a newly established link between extender and matrix Remove Extender Notification about a removed extender from the matrix notification about a switched off extender notification about an interrupted link between extender and matrix Switch Command Notification about a performed switching operation at the matrix Fan Tray 1 Notification about the status of fan tray 1 Fan Tray 2 Not
47. virtual CPU device Edit Edit an existing CPU device Delete Delete an existing CPU device Cancel Reject changes Save Save changes Configuration 2013 08 14 113 Java Tool Select Definition gt CPU Devices in the task area Menu Definition CPU Devices You can select between the following buttons Button Function New Open a new CPU Device Delete Delete a new CPU Device Apply Confirm a created CPU Device Cancel Reject changes gt Assign selected extender units gt gt Assign all available extender units lt Remove the selected extender units lt lt Remove all extender units Draco tera 114 2013 08 14 You can select between the following keyboard commands Function Keyboard Command Change assignment number of the EXT unit upwards lt gt Change assignment number of the EXT unit downwards lt gt In order to create a new CPU device proceed as follows 1 Press the button New 2 Select if a real CPU Create a real CPU or a virtual CPU Create a virtual CPU should be created or a template of an existing CPU should be used Choose template A template can only be used if there is at least one existing CPU device 3 Press the button OK 4 Determine all parameters that are relevant for the CPU 5 To confirm the new CPU press the button Apply In order to access a new CPU via matrix an assignment of one or more CPU type extender un
48. 05_6 doc 52994 3 1 5 3 2 Virtual Console You can assign real consoles to virtual consoles in this menu With this function the effort to set and change access permissions can be reduced by changing the permissions of the virtual console and so applying them to all assigned real consoles too Virtual consoles can be switched exactly in the same way as real consoles If a virtual console is switched to a CPU all real consoles that are assigned to the virtual console will receive the video signal The real console that is lastly scheduled in the list of assignments will additionally receive keyboard and mouse control You have the following possibilities to access the menu Configuration 2013 08 14 73 OSD Select Assignments gt Virtual CON Devices in the main menu Menu Assignments Virtual CON Devices For an assignment proceed as follows 1 Select the real console in the list Real Devices that has to be assigned to a virtual CPU 2 Press the button Edit 3 Select the virtual console in the list Virtual Devices that has to be assigned to the selected real console 4 Press the button Okay to confirm the assignment The assignment will be done A virtual console can be assigned to more than one real consoles Draco tera 74 2013 08 14 Java Tool Select Assignment gt Virtual CON Devices in the task area Menu Assignment Virtual CON Devices In order to place an assignm
49. 06 IHSE Beschreibung Ger teansichten 480 xx Draco tera 48 Port 7 mod_1311324635246_6 doc 54330 3 1 3 6 4 Draco tera 48 Port FILTER TOP 1 2 3 4 5 6 7 OK HS FAN TRAY OK HS FAN TRAY Front View 1 Slot for fan tray 2 Slot for power supply unit 1 3 Slot for I O boards 1 6 4 Slot for power supply unit 2 5 Slot for CPU board 6 Slot for air filter 7 Slot for fan tray 2 Pos 20 806 IHSE zz_Layout Seitenumbruch 8 mod_1348581820516_0 doc 69462 1 Description 2013 08 14 19 Pos 21 806 IHSE Beschreibung Status UEB_Diagnose_und_Status 7 mod_1309935121461_6 doc 52641 2 4 3 7 Diagnostics and Status Pos 22 806 IHSE Beschreibung Diagnose LEDs 480 xx 7 mod_1309934983180_6 doc 52622 3 1 3 7 1 Status LEDs The Draco tera components are fitted with the following LEDs for overall status indication CPU Board Front View Draco tera 20 2013 08 14 Status LEDs on CPU board Pos LED Status Description White CPU board is in registration process Blue flashing Registration at the matrix is started Red flashing Registration in progress Green flashing Operating condition 1 Status 1 Green CPU board de registered White CPU board is in registration process Red flashing Registration at the matrix is started 2 Status 2 Off Operating condition Due to variations in LED type white might also appear as light purple or lig
50. 0758_6 doc 53710 3 1 7 1 4 RS 232 Serial The communication takes place with a transmission speed of up to 115 2 KBaud regardless of the file format The transmission takes place with eight data bits and a stop bit but without a parity bit Limited hardware handshake DSR is possible Pos 124 806 IHSE Technische Daten Schnittstellen RJ45 Ger tekommunikation 5 mod_1278578339308_6 doc 42186 3 1 7 1 5 RJ45 Interconnect The communication of the Cat X devices requires a 1000BASE T connection Connector wiring must comply with EIA TIA 568 B 1000BASE T with RJ45 connectors at both ends All four cable wire pairs are used Pos 125 806 IHSE Technische Daten Schnittstellen Glasfaser SFP Typ LC 5 mod_1278937700855_6 doc 43149 3 1 7 1 6 Fiber SFP Type LC Interconnect The communication of fiber devices is performed via Gigabit SFPs that have to be connected to suitable fibers fitted with connectors type LC see Chapter 7 2 2 Page 182 The correct function of the device can only be guaranteed with SFPs provided by the manufacturer SFP modules can be damaged by electrostatic discharge ESD Please consider ESD handling specifications Pos 126 806 IHSE Technische Daten Schnittstellen SDI Ger tekommunikation 7 mod_1309941998461_6 doc 53674 3 1 Specifications 2013 08 14 181 7 1 7 SDI Interconnect The communication of the SDI devices requires a mini coax connection with
51. 151 806 IHSE Technische Daten Einsatzbedingungen ATB_Einsatzbedingungen 5 mod_1278578980026_6 doc 42480 2 1 7 6 Environmental Conditions Operating Temperature 41 to 113 F 5 to 45 C Storage Temperature 13 to 140 F 25 to 60 C Relative Humidity Max 80 non condensing Pos 152 806 IHSE zz_Layout Seitenumbruch 8 mod_1348581820516_0 doc 69462 1 Specifications 2013 08 14 191 Pos 153 806 IHSE Technische Daten Abmessungen 480 xx 7 mod_1309943734415_6 doc 53966 2 1 7 7 Size Draco tera 288 Matrix 483 x 578 x 330 mm 19 0 x 22 8 x 12 0 Shipping Box 650 x 680 x 760 mm 25 6 x 26 8 x 29 9 Draco tera 160 Matrix 483 x 400 x 330 mm 19 0 x 15 8 x 12 0 Shipping Box 650 x 680 x 540 mm 25 6 x 26 8 x 21 3 Draco tera 80 Matrix 483 x 178 x 230 mm 19 0 x 7 0 x 9 1 Shipping Box 640 x 570 x 360 mm 25 2 x 22 4 x 14 2 Draco tera 48 Matrix 483 x 133 x 230 mm 19 0 x 5 3 x 9 1 Shipping Box 640 x 570 x 316 mm 25 2 x 22 4 x 12 4 Pos 154 806 IHSE zz_Layout Seitenumbruch 8 mod_1348581820516_0 doc 69462 1 Draco tera 192 2013 08 14 Pos 155 806 IHSE Technische Daten Transportgewicht 480 xx 7 mod_1309943775602_6 doc 53984 2 1 7 8 Shipping Weight Draco tera 288 Matrix 34 6 kg 76 2 lb fully equipped Shipping Box 41 1 kg 90 6 lb Draco tera 160 Matrix 26 3 kg 60 0 lb fully equipped Shipping Box 31 7
52. 2 RoHS II The device labels carry a respective marking Pos 176 806 IHSE Glossar ATB_Glossar 5 mod_1278576825433_6 doc 41890 1 1 Glossary 2013 08 14 205 12 Glossary The following terms are commonly used in this guide or in video and KVM technology Term Explanation AES EBU Digital audio standard that is officially known as AES3 and that is used for carrying digital audio signals between devices Cat X Any Cat 5e Cat 6 Cat 7 cable CGA The Color Graphics Adapter CGA is an old analog graphic standard with up to 16 displayable colors and a maximum resolution of 640x400 pixels Component Video The Component Video YPbPr is a high quality video standard that consists of three independently and separately transmittable video signals the luminance signal and two color difference signals Composite Video The Composite Video is also called CVBS and it is part of the PAL TV standard CON Unit Component of a Draco tera or Media Extender to connect to the console monitor s keyboard and mouse optionally also with USB 2 0 devices Console Keyboard mouse and monitor CPU Unit Component of a Draco tera or Media Extender to connect to a source computer CPU CVBS The analog color video baseband signal CVBS is also called Composite Video and it is part of the PAL TV standard DDC The Display Data Channel DDC is a serial communication interface between monitor and source computer CPU
53. 2 Serial 180 7 1 5 RJ45 Interconnect 180 7 1 6 Fiber SFP Type LC Interconnect 180 7 1 7 SDI Interconnect 181 7 2 Interconnect Cable 181 7 2 1 Cat X 181 7 2 2 Fiber 182 7 2 3 Coaxial 183 7 3 Supported Peripherals 184 7 3 1 KVM Extenders with Cat X Connection 184 7 3 2 KVM Extenders with Fiber Connection Single Mode 185 7 3 3 USB 2 0 Extenders with Cat X Connection 186 7 3 4 USB 2 0 Extenders with Fiber Connection Single Mode 187 7 4 Connector Pinouts 188 7 4 1 CPU Board 188 7 4 2 I O Port Cat X 189 7 4 3 I O Port SFP 189 7 4 4 I O Port SDI
54. 2013 08 14 161 Pos 104 806 IHSE Betrieb KVM Schaltung 480 xx 7 mod_1309940863555_6 doc 53563 22 1 6 2 KVM Switching You have the following possibilities to perform switching operations with the Draco tera OSD Select Switch in the main menu By pressing the key lt F8 gt inactive CPU devices can be hidden in order to ensure a better overview Menu Switch To switch the own console to any available CPU proceed as follows 1 Select in the list CPU Devices on the left side that one that should be connected to the own CON device 2 Confirm with the respective keyboard command according to the desired connection type Draco tera 162 2013 08 14 Switching operations from the own CON device can only be done to CPU devices that are available in the list CPU Devices Listed CPU devices highlighted in red color are currently connected in Private Mode and are blocked by the connected CON device Switching via Selection List for CPU Devices The matrix offers the possibility to execute KVM switching operations by a selection list for CPU devices next to the OSD in full screen In order to use the selection list for CPU Devices proceed as follows 1 Activate the option Enable CPU Selection in the menu Configuration for those consoles where the selection list for CPU devices should be available 2 Execute the key sequence for opening the OSD The selection list immediately appears in the preset
55. 3 08 14 Java Tool Select Definition gt EXT Units in the task area Mouse and keyboard settings are made in the tab OSD Data Menu Definition EXT Units Pos 73 806 IHSE zz_Layout Seitenumbruch 8 mod_1348581820516_0 doc 69462 1 Configuration 2013 08 14 123 Pos 74 806 IHSE Konfiguration 480_Konsolen Einstellungen 480 xx Extender OSD 8 mod_1351502028499_6 doc 69501 3 1 5 8 3 Extender OSD In this menu the settings for the Extender OSD can be adjusted These are local settings that can be made individually for each console You can select between the following Extender OSD settings Field Selection Description activated When executing the key sequence for opening the OSD a selection list for switching CPU devices will be displayed in the center of the monitor Pressing the button lt F7 gt within the selection list opens the standard OSD Enable CPU Selection deactivated Function not active default activated Enable Extender OSD default YES Enable Connection Info deactivated Function not active activated Update connection changes during fade in of Extender OSD default YES Update Connection Info deactivated Function not active Display Time 0 999 seconds Duration of OSD fade in default 10 Horizontal Position 10 pixels Horizontal OSD position default 2 Vertical Position 10 pixels Vertical OSD position default 2 When setting the horizo
56. 4 9 2 Safety Instructions To ensure reliable and safe long term operation of your Draco tera please note the following guidelines Installation Only use the device according to this User Manual Otherwise the provided safety can be affected Only use in dry indoor environments The Draco tera and the power supply units can get warm Do not situate them in an enclosed space without any airflow Do not obscure ventilation holes Only use power supplies originally supplied with the product or manufacturer approved replacements Do not use a power supply if it appears to be defective or has a damaged chassis Connect all power supplies to grounded outlets In each case ensure that the ground connection is maintained from the outlet socket through to the power supply s AC power input Do not connect the link interface to any other equipment particularly network or telecommunications equipment Only connect devices to the serial interface that are sufficiently secured against short circuit currents and false voltages at the serial interface To disconnect the Draco tera from the power supply remove the power cord cables of all power supply units that are in use or set the power switch if available to the off position Take any required ESD precautions In order to disconnect the device completely from the electric circuit all power cables have to be removed Repair D
57. 5 2 3 Page 69 4 Enter the user name and password for the Draco tera see Chapter 5 4 1 Page 75 5 Confirm your inputs with the button OK or reject with Cancel Menu Connect Up to twelve connections between the matrix and the Java tool can be established at the same time due to a limitation of available sockets Draco tera 62 2013 08 14 Menu structure Example View System System Data The menu structure of the Java Tools is subdivided into various sections Menu bar top line Toolbar second line Tab bar third line Task area left menu section Working area right menu section Status bar bottom line section Operating Instructions The operation of the Java Tool is intuitive and corresponds to the user interface of common operating systems The Java Tool contains its own support function The integrated help texts in the working area of the Java Tool can be activated or deactivated by the checkbox in the upper right corner Configuration 2013 08 14 63 Mouse Control You can select between the following mouse commands Function Mouse Command Menu selection marking Left mouse button Open function specific selection menus Double click left mouse button Open context specific selection menus Right mouse button Keyboard Control You can select between the following keyboard commands Function Keyboard Command Cursor to the le
58. Apply You can select between the following keyboard commands Function Keyboard Command Add CPU to list Full Access lt F gt Add CPU to list Video Access lt V gt Add CPU to list No Access lt N gt Pos 72 806 IHSE Konfiguration 480_Konsolen Einstellungen 480 xx Maus und Tastatur 7 mod_1309938591211_6 doc 53272 3 1 5 8 2 Mouse and Keyboard The OSD configuration for mouse and keyboard is made in this menu You have the following possibilities to access the menu You can select between the following settings Field Selection Description Hor Speed 1 x 1 9 Adjustment of the horizontal mouse speed 1 slow 9 fast default value 4 Ver Speed 1 x 1 9 Adjustment of the vertical mouse speed 1 slow 9 fast default value 5 Double Click 100 800 Adjustment of the time slot for a double click default value 200 ms Keyboard layout Region Set the OSD keyboard layout according to the used keyboard default German DE Video Mode Variable or specific resolution Resolution that is used when opening OSD The mouse and keyboard settings are console specific and can be separately set for each console Configuration 2013 08 14 121 OSD Select Configuration gt EXT Units in the main menu Menu Configuration EXT Units You can select between the following buttons Button Function Cancel Reject changes Save Save changes Draco tera 122 201
59. CON Unit Single Head 2x USB HID 4x USB 2 0 L477 1STX Draco tera KVM CPU Unit Single Head 2x USB HID 4x USB 2 0 XV R477 1STX Draco tera KVM CON Unit Single Head 2x USB HID 4x USB 2 0 XV L477 2S4S Draco tera KVM CPU Unit Dual Head 4x USB HID R477 2S4S Draco tera KVM CON Unit Dual Head 4x USB HID Draco tera 186 2013 08 14 Type Description L477 2S4X Draco tera KVM CPU Unit Dual Head 4x USB HID XV R477 2S4X Draco tera KVM CON Unit Dual Head 4x USB HID XV L477 1SHSV Draco tera KVM CPU Unit Single Head DVI I input VGA 2x USB HID R477 1SHSV Draco tera KVM CON Unit IR receiver 2x USB HID L477 1SHXV Draco tera KVM CPU Unit Single Head DVI I Input VGA 2x USB HID XV R477 1SHXV Draco tera KVM CON Unit Single HEad DVI I Input VGA 2x USB HID XV K474 Series Type Description L474 BSHS Draco tera KVM CPU Unit Single Head 2x USB HID R474 BSHS Draco tera KVM CON Unit Single Head 2x USB HID L474 BSHX Draco tera KVM CPU Unit Single Head 2x USB HID XV R474 BSHX Draco tera KVM CON Unit Single Head 2x USB HID XV L474 BSHSV Draco tera KVM CPU Unit Single Head DVI I Input VGA 2x USB HID R474 BSHSV Draco tera KVM CON Unit Single Head IR receiver 2x USB HID L474 BSHXV Draco tera KVM CPU Unit Single Head DVI I Input VGA 2x USB HID XV R474 BSHXV Draco tera KVM CON Unit Single Head DVI I Input VGA 2x USB HID XV Pos 135 806 IHSE T
60. D KVM extenders ID is provided by extender unit Serial No and cannot be changed Name Text Name of the extender unit activated Create an extender unit with a fixed port assignment default Fixed deactivated Function not active Port 1 288 depending on the matrix Port number of the extender unit Draco tera 108 2013 08 14 OSD Select Configuration gt EXT Units in the main menu Menu Configuration EXT Units You can select between the following buttons Button Function New Create a new extender unit Edit Edit an existing extender unit Delete Delete an existing extender unit Cancel Reject changes Save Save changes The settings for the tab OSD Data are described in Chapter 5 8 2 Page 120 Configuration 2013 08 14 109 Java Tool Select Definition gt EXT Units in the task area Menu Definition EXT Units You can select between the following buttons Button Function New Create a new extender unit Delete Delete an existing unit Apply Confirm changes of an extender unit Cancel Reject changes 5 6 1 Creating Flex Port Extender Unit Extenders with ID function are automatically recognized by the system and cannot be created manually They were used at so called Flex Ports at the matrix The connection of fixed port extender unit e g USB 2 0 to a Flex Port can cause unintended results Draco tera 110 2013 08 14 5 6 2
61. E Konfiguration Systemeinstellung 480 xx Switch 7 mod_1309938125852_6 doc 53104 3 1 Draco tera 86 2013 08 14 5 4 4 Switch The configuration of the switching parameters is set in this menu You have the following possibilities to access the menu You can select between the following settings Field Selection Description activated The user can switch to any CPU as an observer even to such ones that are already assigned to another user observer without keyboard mouse access Note Switching with the key lt Space gt not lt Enter gt The operator will not be informed if further users connect as an observer to the CPU that is connected to his console Video Sharing deactivated Function not active default activated The user can connect to every single CPU as an operator even to such ones that are related to another user Note The previous user is set to video only status To share K M control Force Connect has to be activated Force Connect deactivated Function not active default activated Extension of Force Connect If the user connects to a CPU as an operator that is already related to another user the connection to the previous user will be completely disconnected Note To share K M control Force Disconnect has to be deactivated Force Disconnect deactivated Function not active default Configuration 2013 08 14 87 Field Selection Description
62. E zz_Layout Seitenumbruch 8 mod_1348581820516_0 doc 69462 1 Configuration 2013 08 14 111 Pos 68 806 IHSE Konfiguration 480_CPU Einstellungen 480 xx 7 mod_1309938442055_6 doc 53216 2 1 5 7 CPU Settings New CPU devices are configured in this menu including their assignment to extenders The assignment helps to describe and switch more complex computer configurations e g Quad Head with USB 2 0 in the matrix You have the following possibilities to access the menu You can select between the following settings Field Selection Description ID Text ID of the CPU unit see Chapter 5 4 2 Page 79 Name Text Name of the CPU Device activated Create new CPU device as a virtual one Virtual Device deactivated Function not active default activated Allow switching to the respective CPU device in Private Mode Allow Private deactivated Function not active default activated Force switching to the respective CPU only in Private Mode Force Private deactivated Function not active default activated Force showing a red frame when switching to the respective CPU Fix Frame deactivated Function not active default Draco tera 112 2013 08 14 OSD Select Configuration gt CPU Units in the main menu Menu Configuration CPU Devices You can select between the following buttons Button Function New R Create a new real CPU device New V Create a new
63. Einstellungen 480 xx Favoritenliste Konsolen 7 mod_1321435290266_6 doc 54758 3 1 5 8 4 Favorite List Consoles Individual favorite lists of CPUs that have to be switched frequently can be created for all consoles in this menu A favorite list can contain up to 16 different CPUs The switching of the favorites is done via Hot Key using the keyboard see Chapter 6 1 1 Page 157 You have the following possibilities to access the menu OSD Select Assignments gt CON Favorites in the main menu Menu Assignments CON Favorites Configuration 2013 08 14 127 To create a favorite list for your own console proceed as follows 1 Select successively these CPUs from the list CPU Devices that have to be moved to the favorite list By pressing the key lt a gt a CPU device will be moved to the favorite list and it will be removed by pressing lt r gt 2 The order of the CPU devices within the favorite list can be changed by pressing the keys lt gt and lt gt 3 Press the button Save to save the settings Java Tool Select the respective user in the working area of the menu CON Devices for the favorite list and open the tab Favorites Menu Definition CON Devices Draco tera 128 2013 08 14 To create a favorite list for any console proceed as follows 1 Select the CPUs in the list CPU available that should be added to the favorite list CPU assigned By pressing the key lt
64. Extender 1 Connect the CON units to the matrix by using the interconnect cables Cat X or fiber 2 Connect the CON units to the input devices that has to be used for example keyboard and mouse 3 Connect the 5VDC power supply units to the CON units 4 Check the basic function of the CON unit by opening the OSD via Hot Key 5 Connect the source computer CPU to the CPU unit of the extender by using the provided connection cables 6 Connect the CPU unit to the matrix by using the interconnect cables Cat X or fiber 7 If you have a video matrix connect the video source directly to the matrix by using the interconnect cables coax fiber 8 Connect the 5VDC power supply units to the CPU units 9 Start the system Pos 36 806 IHSE Installation Installationsbeispiele UEB_Installationsbeispiele_480 xx 7 mod_1311338893738_6 doc 54459 2 1 4 3 Example Applications The Draco tera supports a most flexible configuration of your system environment Pos 37 806 IHSE Installation Installationsbeispiele 480 xx Installationsbeispiele 7 mod_1309936170836_6 doc 52791 1 A part of the Draco tera can be configured as a Single Head work station a part as Dual Head as Quad Head or even as a video matrix for example In addition to that there are configurations with KVM and USB 2 0 available Among the access via OSD by the keyboard connected to the CPU board or an extender CON unit you have the f
65. IHSE Betrieb Bedienung ber HotKeys 480 xx Adressierung von Main Matrix und Sub Matrix 7 mod_1309940780680_6 doc 53526 3 1 6 1 4 Addressing of Main and Sub Matrices The Draco tera can be cascaded in two steps You can optionally send the commands including opening the OSD to the main or the sub matrix Whenever command mode is activated you can select by a lt m gt or a lt s gt if all of the following commands should be handled in the main or in the sub matrix OSD Access OSD access to the main matrix lt Left Shift gt lt Left Shift gt lt m gt optional lt o gt OSD access to the sub matrix lt Left Shift gt lt Left Shift gt lt s gt lt o gt Example Switching to the CPU port 23 of the sub matrix 1 Switching to the CPU Port e g 12 of the master matrix that have the connection to the sub matrix lt Left Shift gt lt Left Shift gt lt 1 gt lt 2 gt lt Enter gt 2 Switching to the CPU Port 23 of the sub matrix lt Left Shift gt lt Left Shift gt lt s gt lt 2 gt lt 3 gt lt Enter gt The selected main matrix sub matrix mode is permanently activated until the other mode will be manually activated This means that if you select lt s gt for example all prospective commands will be sent to the slave but not if the Command Mode is left in the meantime Pos 103 806 IHSE zz_Layout Seitenumbruch 8 mod_1348581820516_0 doc 69462 1 Operation
66. N B2Y 4G62 5 outdoor cable with protection against rodents Only use Single mode connection cables for fiber connections that are based on 3G SFPs Specifications 2013 08 14 183 Maximum Acceptable Cable Length Type of cable 1 25 Gbps 3 125 Gbps Single mode 9 m 10 000 m 32 800 ft 5 000 m 16 400 ft Multi mode 50 m OM3 1 000 m 3 280 ft 500 m 1 640 ft Multi mode 50 m 400 m 1 300 ft 200 m 650 ft Multi mode 62 5 m 200 m 650 ft 100 m 325 ft If you use single mode SFPs with multi mode fibers you normally can increase the maximum acceptable cable length Type of Connector Connector LC Connector Pos 131 806 IHSE Technische Daten Verbindungskabel Koaxial 7 mod_1309942381352_6 doc 53747 3 1 7 2 3 Coaxial A point to point connection is necessary Type of Interconnect Cable Cable Type Specifications Mini coaxial cable AWG 18 RG 6 impedance 75 Maximum Acceptable Cable Length Band Width Maximum Acceptable Cable Length 0 270 Gbit s 400 m 1 312 ft 1 485 Gbit s 140 m 459 ft 2 970 Gbit s 120 m 394 ft Type of Connector Connector Mini BNC connector Pos 132 806 IHSE Technische Daten Unterst tzte Peripherie UEB_Unterst tzte Peripherie 5 mod_1278578478761_6 doc 42242 2 1 Draco tera 184 2013 08 14 7 3 Supported Peripherals Pos 133 806 IHSE Technische Daten Unterst tzte Peripherie 480 xxC 480 xx_KVM Extender Cat X 8
67. OSD Select Configuration gt CON Devices in the main menu Menu Configuration CON Devices You can select between the following buttons Button Function New R Create a real console New V Create a virtual console Edit Edit an existing console Delete Delete an existing console Cancel Reject changes Save Save changes Draco tera 118 2013 08 14 Java Tool Select Definition gt CON Devices in the task area Menu Definition CON Devices You can select between the following buttons Button Function New Open a new CON device Delete Delete a new CON device Apply Confirm a created CON device Cancel Reject changes gt Assign selected extender units gt gt Assign all available extender units lt Remove the selected extender units lt lt Remove all extender units Configuration 2013 08 14 119 You can select between the following keyboard commands Function Keyboard Command Decrease assignment number of the extender unit lt gt Increase assignment number of the extender unit lt gt In order to create a new console proceed as follows 1 Press the button New 2 Select if a real console Create a real Console or a virtual console Create a virtual Console should be created or a template of an existing console should be used Choose template A template can only be used if there is at least on existing CON device 3 Pr
68. RCPU Assign a virtual CPU to a real CPU Configuration 2013 08 14 129 Field Selection Description Set Virtual CON P1 RCON P2 VCON Assign a real console to a virtual console Push P1 CON The own KVM connection is forwarded to console P1 and is changed to a video only connection Push Video P1 CON The video signal of the current connection KVM or video only is forwarded to console P1 The own connection remains unchanged KVM or video only Get P1 CON The own console gets a KVM connection to the CPU that is currently connected to console P1 The connection of console P1 is changed into a video only connection Get Video P1 CON The own console gets a video only connection to the CPU that is currently connected to console P1 The connection of console P1 remains unchanged KVM or video only P1 CON or CPU Device Name of CON or CPU device P2 CPU or CPU Device Name of CON or CPU device You have the following possibilities to access the menu Draco tera 130 2013 08 14 OSD Select via Configuration gt CON Macros in the main menu that console for which a console macro has to be created Menu Configuration CON Macros In order to create a macro for the selected console proceed as follows 1 Select in the field Key that one 1 16 for which a macro should be created 2 Select the respective place on the list 1 16 of the key that should be set with a macro key
69. a 102 2013 08 14 Java Tool Select the respective user in the working area of the menu User for the favorite list and open the tab Favorites Menu Definition User To create a favorite list for any user proceed as follows 1 Select the CPUs in the list CPU available that should be added to the favorite list CPU assigned By pressing the key lt Ctrl gt at the same time more than one CPU device can be marked 2 Press the button gt to move the marked CPU devices to the favorite list If you press the button gt gt the first eight CPU devices from the list CPU available will be moved to the favorite list CPU assigned 3 The order of marked CPU devices within the favorite list can be changed by pressing the keys lt gt and lt gt 4 In order to remove marked CPU devices from the favorite list press the button lt If you press the button lt lt all CPU devices will be removed from the favorite list Pos 65 806 IHSE Konfiguration 480_Benutzereinstellungen 480 xx Benutzer Makros 7 mod_1330938207784_6 doc 57881 3 1 Configuration 2013 08 14 103 5 5 3 User Macros In this menu macro commands for switching disconnection or user administration can be created The macro commands are created for each user separately A macro can execute up to 16 switching commands successively The execution of the macros is done via Hot Key and the function keys lt F1 gt lt F16 gt see Chap
70. allation Lieferumfang pr fen 480 xx 7 mod_1309935842774_6 doc 52736 2 1 4 1 Package Contents Your package contains the following items Draco tera matrix 1x power cord per built in power supply unit 1x serial control cable Mounting accessories Quick Setup Java Tool 1x Cat X network cable cross wired If anything is missing contact your dealer Pos 35 806 IHSE Installation System anschlie en 480 xx 7 mod_1309935998118_6 doc 52754 2 1 4 2 System Setup First time users are recommended to setup the system in the same room as a test setup This will allow you to identify and solve any cabling problems and experiment with your system more conveniently Setup of the matrix 1 Install the CPU and I O boards 2 Connect keyboard mouse and monitor to the CPU board of the matrix 3 Connect the matrix to the power supply 4 Open OSD via Hot Key and login with administrator rights in the main menu under configuration see Chapter 5 2 1 Page 55 5 Configure initially as requested After the configuration of the system it is recommended to save the configuration by selecting Configuration gt Save and restart the matrix by selecting Restart Matrix 6 Optional Establish a network connection between the matrix and the Java tool in order to set an extended configuration see Chapter 5 2 2 Page 60 Installation 2013 08 14 47 Setup of
71. ash In Command Mode normal keyboard and mouse operation will cease Only selected keyboard commands are available If there is no keyboard command executed within 10 s after activating Command Mode it will automatically be deactivated The following table lists the keyboard commands to enter and to exit Command Mode and to change the Hot Key sequence Function Keyboard Command Enter Command Mode default 2x lt Left Shift gt or Hot Key Exit Command Mode lt Esc gt Change Hot Key sequence lt current Hot Key gt lt c gt lt new Hot Key code gt lt Enter gt Until 2011 30 09 lt Left Ctrl gt lt Left Shift gt lt c gt lt Hot Key Code gt lt Enter gt lt Key gt lt Key gt Press keys simultaneously lt Key gt lt Key gt Press keys successively 2x lt Key gt Press key quickly twice in a row similar to a mouse double click Draco tera 54 2013 08 14 The Hot Key sequence to enter Command Mode can be changed The following table lists the Hot Key Codes for the available key sequences Hot Key Code Hot Key 0 Freely selectable from 2012 01 12 on 2 2x lt Scroll gt 3 2x lt Left Shift gt 4 2x lt Left Ctrl gt 5 2x lt Left Alt gt 6 2x lt Right Shift gt 7 2x lt Right Ctrl gt 8 2x lt Right Alt gt In a combined KVM matrix U Switch configuration choose different Hot Keys for the KVM matrix and the U Switch Set freely se
72. at this port In order to show the extender information of the currently selected port in the right part of the working area press the left mouse button Description 2013 08 14 29 The following information is available Field Description Extender Name Name of the selected extenders Extender Type Type of the selected extender Port ID Number of the selected port Device Name Name of the connected console or CPU Connections Listing of assigned connections to the marked port Full Access or Video Access In order to open the context menu for the currently selected port with further functions press the right mouse button The following context functions are available Function Description Open Extender The menu for definition of the currently selected extender will be opened Open Device The menu for definition of the currently selected console or CPU will be opened Switch The menu for execution of switching operations will be opened In order to reload the Matrix View you have the following possibilities Press the key lt F5 gt on a connected keyboard Execute Edit gt Reload in the menu bar Press the Button Reload in the tool bar Pos 25 806 IHSE Beschreibung Status Extender OSD 480 xx 7 mod_1317829749536_6 doc 54621 3 1 Draco tera 30 2013 08 14 3 7 3 Extender OSD All extenders used with the Draco tera are provided with their own OSD to display the con
73. cal or an older firmware version as the version that is currently installed the option Force Update in the lower part of the working area has to be enabled Menu Administration Update EXT Firmware 5 Start the actual update process by pressing the button Update Just before the update process all affected I O boards will be set into Service Mode and retrieved gradually after finishing the respective updates Configuration 2013 08 14 153 Performing the Update in Expert Mode sequential Update Take the following steps in order to be prepared for the extender update 1 Select Administration gt Update EXT Firmware and select Expert Mode in the upper part of the working area All updateable extenders will be automatically selected and highlights in green Menu Administration Update EXT Firmware 2 Set the matrix into Service Mode upon request in the popup window or via Matrix gt Activate Service Mode in the menu bar During activation all matrix functions are disabled on the I O boards on which an update is currently performed An OSD picture indicates the activation of the Service Mode and is displayed on all monitors that are connected to the matrix via a CON device Additionally the Service Mode is indicated by a red tool icon in the lower part of the working area Draco tera 154 2013 08 14 OSD View Service Mode 3 Start the update by pressing the button Update in the lower part of the working
74. complete control Example Switching to favourite CPU 7 with video keyboard and mouse lt left Shift gt lt left Shift gt lt 7 gt lt Enter gt Best results regarding switching time can be achieved by using identical mice keyboards and monitors This contributes to a smooth and seamless direct switching of the matrix Switching in Private Mode 1 Start Command Mode with the Hot Key For control the LEDs Shift and Scroll flashes at the keyboard if command mode is activated 2 Enter the index number of the new CPU from the list of favorites and confirm with lt left Shift gt lt Enter gt pressed at the same time At the same time the Command Mode is closed and the console is connected to the new CPU with complete control in Private Mode Example Switching to favorite CPU 3 in Private Mode lt left Shift gt lt left Shift gt lt 3 gt lt left Shift gt lt Enter gt Draco tera 158 2013 08 14 Direct Switching of Video 1 Start Command Mode with the Hot Key For control the LEDs Shift and Scroll flashes at the keyboard if command mode is activated 2 Enter the index number of the new CPU from the list of favorites and confirm with lt Space gt At the same time the Command Mode is closed and the console is connected to the new CPU with video only Example Switching to favourite CPU 1 with video only lt left Shift gt lt left Shift gt lt 1 gt lt Space gt Switch to
75. ct OSD access lt Hot Key gt lt Num 0 gt Switching of the USB HID signal to the own display CON Unit with keyboard and mouse lt Hot Key gt lt Num 1 gt Switching of the USB HID signals to display 1 lt Hot Key gt lt Num 2 gt Switching of the USB HID signals to display 2 lt Hot Key gt lt Num 3 gt Switching of the USB HID signals to display 3 lt Hot Key gt lt Num 4 gt Switching of the USB HID signals to display 4 Pos 118 806 IHSE Technische Daten UEB_Technische Daten 5 mod_1278578165261_6 doc 42096 1 1 Specifications 2013 08 14 179 7 Specifications Pos 119 806 IHSE Technische Daten Schnittstellen UEB_Schnittstellen 5 mod_1278578201870_6 doc 42114 2 1 7 1 Interfaces Pos 120 806 IHSE Technische Daten Schnittstellen DVI D Single Link 5 mod_1278578254058_6 doc 42132 3 1 7 1 1 DVI D Single Link The video interface supports the DVI D protocol All signals that comply to DVI D Single Link norm can be transmitted This includes e g monitor resolutions such as 1920x1200 60Hz Full HD 1080p or 2K HD up to 2048x1152 Data rate is limited to 165 MPixel s Pos 121 806 IHSE Technische Daten Schnittstellen USB HID 5 mod_1278578292214_6 doc 42150 3 1 7 1 2 USB HID Our devices with USB HID interface support a maximum of two devices with USB HID protocol Each USB HID port provides a maximum current of 100 mA Keyboard Compatible with most USB
76. ction not active default activated Newly created CON devices automatically receive access to all CPUs Enable new CON deactivated Function not active default activated Upon opening the OSD the console will be automatically disconnected from the current CPU Auto Disconnect deactivated Function not active default Configuration 2013 08 14 83 Field Selection Description OSD Timeout 0 999 seconds Period of inactivity after which OSD will be closed automatically Select 0 seconds for no timeout default 0 seconds Auto Logout 0 999 minutes Period of inactivity of a logged in user at a console after which he will be automatically logged out at this console There might be a disconnect because of the logout depending on the defined rights in each CON and user ACL Select 0 minutes for an automatic user logout when leaving OSD Using the setting 1 allows the user to be logged in permanently until a manual logout is executed The timer is not active as long as the OSD is open default 0 minutes Draco tera 84 2013 08 14 OSD Select Configuration gt Access in the main menu Menu Configuration Access You can select between the following buttons Button Function Cancel Reject changes Save Save changes Configuration 2013 08 14 85 Java Tool Select System gt Access in the task area Menu System Access Pos 57 806 IHS
77. d be standardly sourced 2 Connect all hot spare extenders to the matrix For reasons of network stability an update via WLAN is not recommended Configuration 2013 08 14 151 Performing the Update in Standard Mode parallel Update 1 Select Administration gt Update EXT Firmware in the task area The standard mode for the parallel update will be selected by default and the tab Upload Firmware will be opened Menu Administration Update EXT Firmware 2 Before the actual update process all firmware files have to be uploaded to the respective I O boards on that extenders will have to be updated By selecting the update files the I O boards will be automatically chosen for the upload in the column Selected and highlighted in green but only if a newer firmware version is selected 3 Start the upload and distribution of the update files by pressing the button Upload By performing the upload process no update files will be installed the update process can be performed at a later time If there are not selected all I O cards the upload of the update files will be performed in sequence Draco tera 152 2013 08 14 4 After finishing the upload process the successful completion will be confirmed by a popup If you want to directly start the actual update process you will have to confirm this by pressing the button Yes You will be immediately forwarded to the tab Update Firmware When updating an identi
78. d suboptimal and faulty settings and to point these out The System Check is exclusively used for a plausibility check and does not make any active changes in the configuration You have the following possibility to access the menu The following configuration parts are checked Matrix Firmware Extender Firmware Multi Screen Control Ext Units CPU Devices CON Devices User System Configuration The following notification levels can be shown Level Description OK green System Check completed without any abnormalities WARNING yellow System Check revealed abnormalities in the configuration that point out to incomplete parts of the configuration firmware differences duplications or not connected extenders but without being system critical ERROR red System Check revealed errors in the configuration that can have both functional and system critical influences on the system If the messages WARNING and ERROR are created by the System Check function the respective problem will be described and a basic guideline will be provided Description 2013 08 14 45 In order to start System Check proceed as follows Select the symbol System Check in the symbol bar Menu System Check Pos 33 806 IHSE Installation UEB_Installation 5 mod_1278574971589_6 doc 41768 1 1 Draco tera 46 2013 08 14 4 Installation Pos 34 806 IHSE Inst
79. der unit CPU unit CPU assigned Real CPU device that is assigned to a virtual CPU device CON connected Currently connected CON device CPU status Current connection status CPU device EXT list List of all available physical extender units CPU units You can select between the following switching functions Function Keyboard Command Set a video only connection lt Space gt Set a KVM connection lt Enter gt Set a KVM connection in private mode video sharing disabled lt Shift gt lt Enter gt Disconnect own CON device from CPU device lt Backspace gt Draco tera 166 2013 08 14 Java Tool You have two possibilities to perform switching operations for the Draco tera via Java Tool Possibility 1 Select Control gt Extended Switch in the task area Menu Control Extended Switch All connected consoles and the associated CPU connections are shown in columns in the working area in this menu Switching operations can only be performed in online mode That means an active network connection between the matrix and the Java Tool is required In order to set a KVM connection between a console and a CPU double click on the corresponding selection box within the column Full Access and select the requested CPU In order to set a video connection between a console and a CPU double click on the corresponding selection box within the column Video Only and select the requested CPU
80. e and number of sales receipt name of dealer if necessary Issue date of the existing manual Nature circumstances and duration of the problem Involved components such as graphic source CPU OS graphic card monitor USB HID USB 2 0 devices interconnect cable including manufacturer and model number Results from any testing you have done 10 2 Shipping Checklist 1 To return your device contact your dealer to obtain a RMA number Return Material Authorization 2 Package your devices carefully preferably using the original box Add all pieces which you received originally 3 Note your RMA number visibly on your shipment Devices that are sent in without a RMA number cannot be accepted The shipment will be sent back without being opened postage unpaid Pos 171 806 IHSE Zertifikate UEB_Zertifikate 5 mod_1278579534933_6 doc 42668 1 1 Draco tera 202 2013 08 14 11 Certificates Pos 172 806 IHSE Zertifikate ATB_Europ ische Konformit tserkl rung 5 mod_1278579640901_6 doc 42686 2 1 11 1 CE Declaration Of Conformity The products listed below in the form as delivered comply with the provisions of the following European Directives 2004 108 EG Council Directive on the approximation of the laws of the Member States relating to electromagnetic compatibility CE Marking 2009 Product list K480 Serie The products comply with the following harmonized standards fo
81. e g by a firewall During logging the activities are written continuously into logging files and stored locally This process can be set with various options Description 2013 08 14 39 Options Select Extras gt Options in the menu bar and open the tab Syslog The following options are available Option Description Log File Directory Default directory to store the log files Log File Name Default name of the log file Log File Extension Default extension for the log file Maximum Log File Size KB Allowed maximum size of log file Maximum Number of Log Files Allowed maximum number of log files When reaching the maximum log file size a new log file will be created When reaching the maximum number of log files the oldest one will be overwritten with the new information Filter Function In order to filter relevant messages out of a number of logged activities of the Draco tera the Syslog Monitoring offers various filter options In order to set and activate a filter proceed as follows 1 Set the desired filter option s by activating the respective checkbox es 2 Activate the filter settings by pressing the button Filter 3 In order to deactivate an activated filter setting press the button Clear The following filter options are available Option Description Date Messages of a defined date range will be filtered Facility Messages of a defined facility will be filtered Seve
82. echnische Daten Unterst tzte Peripherie 480 xxC 480 xx_USB 2 0 Extender Cat X 8 mod_1345796161347_6 doc 68101 3 4 7 3 3 USB 2 0 Extenders with Cat X Connection K474 Series Type Description L474 BXTC Draco tera USB 2 0 CPU Unit 4x USB 2 0 R474 BXTC Draco tera USB 2 0 CON Unit 4x USB 2 0 Pos 136 806 IHSE Technische Daten Unterst tzte Peripherie 480 xx USB 2 0 Extender Glasfaser 7 mod_1311332022526_6 doc 54422 3 1 Specifications 2013 08 14 187 7 3 4 USB 2 0 Extenders with Fiber Connection Single Mode K474 Series Type Description L474 BXTS Draco tera USB 2 0 CPU Unit 4x USB 2 0 R474 BXTS Draco tera USB 2 0 CON Unit 4x USB 2 0 L474 BXTX Draco tera USB 2 0 CPU Unit 4x USB 2 0 XV R474 BXTX Draco tera USB 2 0 CON Unit 4x USB 2 0 XV Pos 137 806 IHSE zz_Layout Seitenumbruch 8 mod_1348581820516_0 doc 69462 1 Pos 138 806 IHSE Technische Daten Pinbelegungen UEB_Pinbelegungen 5 mod_1278578683636_6 doc 42315 2 1 Draco tera 188 2013 08 14 7 4 Connector Pinouts Pos 139 806 IHSE Technische Daten Pinbelegungen UEB_CPU Karte 7 mod_1309942897790_6 doc 53820 3 1 7 4 1 CPU Board Pos 140 806 IHSE Technische Daten Pinbelegungen Buchse DVI D Single Link 5 mod_1278578723073_6 doc 42333 1 Connector DVI D Single Link 1 8 C1 C2 C5 17 24 C3 C4 Pin Signal Pin Signal Pin Signal 1 T M
83. ence or as a square When using sources computers CPUs in multi head operation e g dual head the switching is only working manually via keyboard commands Any non observance may have a negative influence on the stability of the system In order to enable Multi Screen Control all Extender Units assigned to the related CON device have to be physically connected to the same block of 4 ports on the I O board of the matrix CON Units that have been already configured for Multi Screen Control can be connected together to other blocks of 4 ports In this case any further configuration is not necessary The functionality will be still available You have the following possibilities to access the menu Draco tera 136 2013 08 14 OSD Select Assignments gt Multi Screen Control in the main menu Menu Assignments Multi Screen Control In order to configure the Multi Screen Control proceed as follows 1 Select in the field Arrangement the respective display arrangement that is available at the CON Device you want to configure 1 x 4 or 2 x 2 The fields for the configuration of the individual displays will be arranged accordingly 2 Activate the option Manual if the USB HID switching should only be allowed by using keyboard commands see Chapter 6 7 Page 173 The manual switching allows the use of multi head consoles 3 Ensure that the option Enabled is set to Y on all used displays in order to activa
84. ent proceed as follows 1 Select the required real console in the table Real Console 2 Double click in the column Virtual Console to get a list of all available virtual consoles 3 Select the required virtual console You can select between the following buttons Button Function Send Send assignments to the matrix Cancel Reject changes When activating the function Auto Send in the left lower corner of the working area switching operations will be done immediately without confirmation by pressing the button Send The selection boxes in the column Virtual Console contain a filter function for an easy selection of a single CPU from a larger pool of CPUs see Chapter 5 2 2 Page 60 Pos 51 806 IHSE Konfiguration Systemeinstellung 480 xx Systemeinstellungen 7 mod_1309937961274_6 doc 53032 2 1 Configuration 2013 08 14 75 5 4 System Settings You have the possibility to configure the following system settings at the Draco tera The configuration of the system settings can only be done by users with administrator rights Pos 52 806 IHSE Konfiguration Systemeinstellung 480 xx System Data 7 mod_1309938005493_6 doc 53050 3 1 5 4 1 System Data The system configuration is set in this menu You have the following possibilities to access the menu You can select between the following settings Field Selection Description Device Text Enter the device name of the matrix default
85. ers switching in between without continuously using the Hot Key The switching between two video signals can even take place within one frame 1 Start command mode with the Hot Key For control the LEDs Shift and Scroll flashes at the keyboard if command mode is activated 2 Press the key lt Left Shift gt and hold it down You can now enter the index numbers of the various CPUs from the list of favorites with the keyboard and immediately switch to the video signal of the respective CPU after entering the index number 3 Leave Scan Mode by pressing lt Left Shift gt lt Esc gt Optimal results can be achieved by the use of as identical resolutions as possible This contributes to a smooth and seamless function of the scan mode Pos 100 806 IHSE Betrieb Bedienung ber HotKeys 480 xx Funktionstasten lt F1 gt lt F16 gt 7 mod_1309940812665_6 doc 53544 3 1 6 1 3 Function Keys lt F1 gt lt F16 gt In Command Mode you can retrieve the macros 1 16 with the function keys lt F1 gt lt F16 gt of the connected standard keyboard instead of the special macro keyboard The deposited command sequence for the appropriate function key is executed and Command Mode is left immediately Regarding macros there is no necessity of using the key lt Enter gt for confirmation Pos 101 806 IHSE zz_Layout Seitenumbruch 8 mod_1348581820516_0 doc 69462 1 Draco tera 160 2013 08 14 Pos 102 806
86. es from the CPU board 3 Pull the CPU board out of the corresponding slot by using the locking pin 4 Push a new or maintained CPU board into the slot and lock it accordingly A successful registration of the CPU board will be shown by a permanent green flashing of status LED 1 5 Connect all cables to the CPU board according to the exchanged board When exchanging a CPU board the new one will automatically receive the current matrix configuration During CPU board exchange the Draco tera should not be switched off 8 4 I O Board In order to exchange a I O board proceed as follows 1 Pull the locking pin slowly out of the I O board up to the stop Wait until the I O board will be deregistered from the matrix The deregistration will be confirmed by a permanent green light of the status LED 1 at the CPU board see Chapter 3 7 1 Page 19 2 Remove all cables from the I O board 3 Pull the I O board out of the corresponding slot by using the locking pin 4 Push a new or maintained CPU board into the slot and lock it accordingly A successful registration of the CPU board will be shown by a permantent green flashing of status LED 1 5 Connect all cables to the I O board according to the exchanged board Draco tera 196 2013 08 14 For the use in a 24 7 operation it is recommended to keep all relevant components of the matrix including a chassis as spare parts available 8 5 Filter Pads
87. ess the button OK 4 Determine all parameters that are relevant for the console 5 To confirm a created console press the button Apply In order to run a created CPU via matrix it requires an assignment of one or more CON units extender To place an assignment please proceed as follows 1 Select the console in the list CON Devices that has to be assigned to an extender 2 Select the extender in the list Extender available that should be assigned to the CON 3 Perform the assignment by pressing the button gt To assign all available extenders to the console press the button gt gt The assignments are displayed in the list Extender assigned 4 Confirm the assignment by pressing the button Apply In order to remove an extender assignment proceed as follows 1 Select the console in the list CON Devices to be modified 2 Select the extender s in the list Extender assigned to be removed 3 Remove the assignment with the button lt To remove all existing assignments press the button lt lt 4 Confirm the changes by pressing the button Apply Draco tera 120 2013 08 14 In order to configure CPU access rights of consoles proceed as follows 1 Select a console in the list CON Devices 2 Open the tab CPU Access Control 3 Assign new access rights by using the right mouse button or the respective keyboard commands cf below 4 Confirm the configuration by pressing the button
88. ext functions are described in the respective chapters In order to execute a context function use the right mouse button on the corresponding field and select the desired function Sorting Function Lists and tables in the Java Tool offer a sorting function for fast and smooth search 1 For ascending sort status use the left mouse button once to click into the header of the column to be sorted The sort status is indicated by an arrow that points upwards 2 For descending sort use the left mouse button twice to click on the header of the column that has to be sorted The sort is displayed by an arrow that points downwards 3 In order to cancel the sort use the left mouse button once or twice to click on the header of the column that is sorted until the displayed arrow will disappear Configuration 2013 08 14 65 Filter Function Lists and tables in the Java Tool offer a filter function that allows a fast and smooth search inside 1 In order to activate a filter use the right mouse button to click on the header of the column that has to be filtered and select Set Filter 2 Write directly the word or part of a word that has to be filtered into the header The filter results are shown immediately 3 In order to delete a filter use the right mouse button to click on the header of the column that has to be filtered and select Clear Filter An active filter is indicated by an asterix in the header
89. figurationen intern 7 mod_1309938889118_6 doc 53346 3 1 5 9 3 Loading of Configurations internal Previously saved configurations are loaded in this menu You have the following possibilities to load configurations from files In Active the currently loaded configuration is displayed In addition to the default configuration up to eight further configurations can be loaded The selection of the configuration that has to be loaded can be made between eight personalizable configurations and the default settings The selected configuration is will be immediately loaded and displayed in the menu as Active The previously active configuration is deleted OSD 1 Select Configuration gt Open in the main menu 2 Select the desired configuration 3 Load the configuration by pressing the key lt Enter gt Menu Configuration Open Configuration 2013 08 14 143 Java Tool 1 Select Administration gt Activate Configuration during online mode in the task area 2 Select the required configuration 3 Load the configuration by pressing the button Activate Menu Administration Activate Configuration Pos 85 806 IHSE zz_Layout Seitenumbruch 8 mod_1348581820516_0 doc 69462 1 Draco tera 144 2013 08 14 Pos 86 806 IHSE Konfiguration 480_Speichern und Laden von Konfigurationen 480 xx Speichern von Konfigurationen extern 7 mod_1309938846930_6 doc 53328 3 1 5 9 4 Savin
90. for fan tray 1 3 Slot for power supply unit 2 4 Slot for fan tray 2 5 Slot for I O boards 1 36 6 Slot for power supply unit 3 7 Slot for CPU board 8 Grounding Pos 14 806 IHSE zz_Layout Seitenumbruch 8 mod_1348581820516_0 doc 69462 1 Draco tera 16 2013 08 14 Pos 15 806 IHSE Beschreibung Ger teansichten 480 xx Draco tera 160 Port 7 mod_1309934740805_6 doc 52568 3 1 3 6 2 Draco tera 160 Port FILTER 1 2 3 4 5 6 7 OK HS FAN TRAY OK HS FAN TRAY 8 Front View 1 Slot for power supply unit 1 2 Slot for fan tray 1 3 Slot for power supply unit 2 4 Slot for fan tray 2 5 Slot for I O boards 1 20 6 Slot for power supply unit 3 7 Slot for CPU board 8 Grounding Pos 16 806 IHSE zz_Layout Seitenumbruch 8 mod_1348581820516_0 doc 69462 1 Description 2013 08 14 17 Pos 17 806 IHSE Beschreibung Ger teansichten 480 xx Draco tera 80 Port 7 mod_1309934775696_6 doc 52586 3 1 3 6 3 Draco tera 80 Port FILTER TOP 1 2 3 4 5 6 7 OK HS FAN TRAY OK HS FAN TRAY Front View 1 Slot for fan tray 2 Slot for power supply unit 1 3 Slot for I O boards 1 10 4 Slot for power supply unit 2 5 Slot for CPU board 6 Slot for air filter 7 Slot for fan tray 2 Pos 18 806 IHSE zz_Layout Seitenumbruch 8 mod_1348581820516_0 doc 69462 1 Draco tera 18 2013 08 14 Pos 19 8
91. ft lt Cursor Left gt Cursor to the right lt Cursor Right gt Line up lt Cursor Up gt Line down lt Cursor Down gt Previous page in input or status menus with more than one page lt Page Up gt Next page in input or status menus with more than one page lt Page Down gt Next field in input menus lt Tab gt Previous field in input menus lt Left Shift gt lt Tab gt Switching in selection fields between two conditions checkmark or not Open already marked fields with editing or selecting possibility lt Space gt In menus Data saving Menu item selection lt Enter gt Leave tables Jump from tables into the next field lt Ctrl gt lt Tab gt Leave tables Jump from tables into the previous field lt Ctrl gt lt Left Shift gt lt Tab gt Various functions within the menus in the menu bar can be executed with the provided keyboard commands e g press lt Ctrl gt lt S gt to execute Save that are listed to the right of the respective menu item Draco tera 64 2013 08 14 Reload Options The information shown in the Java Tool can be reloaded in different ways Via lt F5 gt key on the used keyboard Via Edit gt Reload in the menu bar Via Reload Symbol in the symbol bar Context Function The Java Tool offers several context functions that support a user friendly and effective operation of the tool The cont
92. fulfilled Computer with an executable Java Tool and an installed Java Runtime Environment JRE version 1 6 or higher Java Tool software Available network connection between the Java Tool and the matrix Contact your system administrator concerning JRE and network connection Installation of the Java Tool The Java Tool is available as a single executable program file that does not require a separate installation Copy the tool after receiving the file to a directory on your computer If you do not have a Java Tool contact your dealer Computer Connection to the Matrix For a direct connection between computer and matrix a cross wired network cable is required For a connection between computer and matrix via switch or hub a parallel assembled network cable is required Do not use a network connection between Java Toll and the matrix that is primarily used for transmitting audio data Connect the network cable to the RJ45 ports of computer and CPU board of the matrix Start of the Java Tool Open the Java Tool by a double click on the program icon or use the lt Enter gt key of the keyboard Configuration 2013 08 14 61 Connection to the Matrix At least FTP rights are required 1 Open the Java Tool 2 Select Matrix gt Connect in the menu bar 3 Enter the IP address in the popup input field according to the network configuration of the Draco tera see Chapter
93. g of Configurations 139 5 9 1 Active Configuration 139 5 9 2 Saving of Configurations internal 139 5 9 3 Loading of Configurations internal 142 5 9 4 Saving of Configurations external 144 5 9 5 Loading of Configurations external 145 5 10 Export and Import Options 146 5 10 1 Export Options 146 5 10 2 Import Options 147 5 11 Firmware Update 148 5 11 1 Matrix Update 148 5 11 2 Extender Update 150 5 12 License Management 154 6 Operation 156 6 1 Operation via Hot Keys 157 6 1 1 Direct Switching 157 6 1 2 Scan Mode 159 6 1 3 Function Keys lt F1 gt lt F16 gt 159 6 1 4 Addressing of Main and Sub Matrices 160 6 2 KVM
94. g of Configurations external Created configurations can be saved as a file and so become independent of the matrix and transportable You have the following possibility to access the menu 1 Select File gt Save As in the menu bar 2 Enter a name for the configuration 3 Select the directory of the configuration on your storage medium where it has to be saved Configurations are always saved in a file with the ending dtc Menu File Save As Pos 87 806 IHSE Konfiguration 480_Speichern und Laden von Konfigurationen 480 xx Laden von Konfigurationen extern 7 mod_1309938925211_6 doc 53364 3 1 Configuration 2013 08 14 145 5 9 5 Loading of Configurations external Externally saved configurations are opened and activated in this menu You have the following possibilities to load configurations from files 1 Select File gt Open during offline mode and select the storage location of the configuration file that has to be opened 2 Open the configuration by pressing the button Open 3 Select File gt Upload in the menu bar to transfer the opened configuration to the matrix Enter the necessary parameters 4 Select Matrix gt Connect in the menu bar to make a connection between the matrix and the Java tool Enter the necessary parameters 5 Select Administration gt Activate Configuration and select the configuration that has to be activated 6 Confirm the process with the but
95. he cache by using the function Copy Key Macros You can paste the macros from the cache into a key by using the function Paste Key Macros and you can reset all macros of the selected key by using the function Reset Key Macros Pos 78 806 IHSE Konfiguration 480_Konsolen Einstellungen 480 xx Konkurrierende Bedienung 9 mod_1375170037949_6 doc 79211 3 1 5 8 6 Parallel Operation In this chapter you can find an instruction of configuring the parallel operation of a CPU Device by two or more CON Devices The control of the CPU Device can be done by only one CON Device at a time but can be taken over exclusively by other CON Devices too Taking over control is immediately possible or after the expiry of an inactivity timer of the controlling CON Device You can use the mouse or keyboard in order to take over control In order to allow a smooth and accurate function of the parallel operation you should use identical mice and keyboards They should be connected to the same USB HID ports of each CON Unit The alternative is using the USB HID Ghosting see Chapter 6 10 Page 177 You have the following possibilities to configure parallel operation Configuration 2013 08 14 133 OSD Select Configuration gt Switch in the main menu Menu Configuration Switch In order to configure parallel operation proceed as follows 1 Activate the function Enable Video Sharing 2 Activate the function Force Connect 3
96. ht blue Description 2013 08 14 21 I O Board Cat X SFP Fiber SFP Coax Front View Draco tera 22 2013 08 14 Status LEDs at I O boards Pos LED Status Description Light blue I O board in boot process Red flashing I O board in registration process Red Yellow flashing I O board in Service Mode or firmware conflict with CPU board Green flashing Operating condition I O board registered at the matrix 1 Status 1 Green I O board de registered locking pin pulled out White I O board in boot process Blue I O board in registration process Blue flashing Operating condition communication active with CPU board active 2 Status 2 Red flashing I O board de registered locking pin pulled out Description 2013 08 14 23 Ports I O Board Cat X SFP Fiber SFP Coax Front View 1 Status LED 1 2 Status LED 2 Status LEDs at the ports of the I O boards Pos LED Status Description Off Port not activated 1 Link status orange Flashing Port activated no connection via interconnect cable Off Port not activated Flashing Port activated no connection via interconnect cable 2 Link status green On Connection via interconnect cable ok data traffic active Draco tera 24 2013 08 14 Fan Tray OK HS FAN TRAY 1 2 3 Front View 1 Status LED 1 2 Status LED 1 3 Hot Swap LED Status LEDs of the fan trays Pos LED Stat
97. ices that has to be assigned to the selected virtual CPU 4 Press the button Okay to confirm the assignment The assignment will be done Only one virtual CPU can be assigned to a real CPU Configuration 2013 08 14 71 Java Tool Select Assignment gt Virtual CPU Devices in the task area Menu Assignment Virtual CPU Devices For an assignment proceed as follows 1 Select a virtual CPU in the list Virtual CPU 2 Double click in the column Real CPU to get a list of all available real CPUs 3 Select a real CPU You can select between the following buttons Button Function Send Send assignments to the matrix Reload Reload changes When activating the function Auto Send in the left lower corner of the working area switching operations will be done immediately without confirmation by pressing the button Send Draco tera 72 2013 08 14 The selection boxes in the column Real CPU contain a filter function for an easy selection of single consoles from a larger pool of consoles see Chapter 5 2 2 Page 60 The Java tool additionally offers the possibility to go directly from the menu Assignment to the menu Definition to check specific settings for the respective console or CPU Use the right mouse button to select the respective console or CPU and select Open CON Device or Open CPU Device Pos 50 806 IHSE Konfiguration 480_Zuordnung 480 xx Virtuelle Konsole 7 mod_13099378428
98. ification about the status of fan tray 2 Power Supply 1 Notification about the status of power supply unit 1 Power Supply 2 Notification about the status of power supply unit 2 Power Supply 3 Notification about the status of power supply unit 3 For an activation of the SNMP agent function or the SNMP server function a restart of the matrix is obligatory Description 2013 08 14 43 Java Tool In order to activate the SNMP agent proceed as follows 1 Select System gt Network in the task area Menu System Network 2 Activate the option SNMP Agent in the tab SNMP By activating this option the permission for an active query of the SNMP agent is granted In order to configure a SNMP Server proceed as follows 1 Select Configuration gt Network in the task area 2 Activate the option Enable Traps within SNMP Server This function allows an active transmission of trap messages from the SNMP agent to the SNMP server 3 Set the IP address of the SNMP within SNMP Server 4 Activate the requested traps For an activation of the SNMP agent function or the SNMP server function a restart of the matrix is required Pos 32 806 IHSE Beschreibung System Check 480_xx 9 mod_1375105102198_6 doc 78732 2 1 Draco tera 44 2013 08 14 3 11 System Check The System Check offers a diagnostic function for checking your current matrix configuration The purpose of this feature is to fin
99. ing operations between CON and CPU devices proceed as follows 1 Move the mouse cursor to the port that has to be switched 2 Hold down the left mouse button and move the cursor to the port that has to be connected to the initial port The current cursor movement will be displayed by a black auxiliary line 3 Release the left mouse button A popup to select the available switching type Full Access Video Access or Private Mode will be opened 4 Select the desired switching type The switching operation will be immediately executed At the same time all extender units that are assigned to the involved devices will be switched If there is a red cross on a port when switching by using the Matrix View the console to be connected does not have access rights to the respecting CPU at this port Operation 2013 08 14 169 In order to disconnect existing connection between CON and CPU devices proceed as follows 1 Click on the port that has to be disconnected by using the right mouse button 2 Select the function Disconnect in the appearing popup The connected ports will be immediately disconnected At the same time all further connections of the extenders assigned to the involved devices will be disconnected Pos 105 806 IHSE Betrieb 480_CON Switch 480_CON Switch 9 mod_1375172364133_6 doc 79232 2 4 6 4 CON Switch KVM extender CON Units connected to a local source computer CPU can be locally switched
100. ion via OSD via Java Tool via serial interface Pos 45 806 IHSE Konfiguration 480_Ansteuerung 480 xx Ansteuerung via OSD 7 mod_1309937635540_6 doc 52920 3 1 5 2 1 Control via OSD Via OSD On Screen Display you set the configuration of the Draco tera operating system The settings of the menu Configuration are described below All other menus are described in later chapters You have the following possibilities to enter the OSD of the Draco tera via keyboard connected to the CPU board via keyboard connected to a CON unit of an extender Entering OSD 1 Start Command Mode with the Hot Key see Chapter 5 1 Page 53 2 Press lt o gt to open OSD You will see a list of all available CPUs as a start menu 3 Press lt Esc gt to enter the main menu If the option Enable CPU Selection is activated in the menu Configuration first of all the selection list for switching CPU devices will be opened This list can be skipped by pressing the key lt F7 gt Leaving OSD Press the key lt Esc gt in the main menu or simultaneously lt Left Shift gt lt Esc gt anywhere within the OSD The OSD will be closed without any further changes and the currently active CPU connection will be displayed Draco tera 56 2013 08 14 Menu Structure Example View The general layout of the OSD is structured into three areas Upper status area topmost two text lines
101. ion not active default Syslog Server Byte Input of the IP address of the Syslog servers in the form 192 168 1 1 Configuration 2013 08 14 91 Field Selection Description DEB Activate debug messages in Trace default NO Note The debug messages are exclusively for matrix diagnostics They only should be activated after consultation with the manufacturer Otherwise an increased traffic of data might limit the performance of the CPU board INF Activate information messages in Trace default NO NOT Activate notification messages in Trace default YES WAR Activate warning messages in Trace default YES Trace ERR Activate error messages in Trace default YES DEB Activate debug messages in Syslog default NO Note The debug messages are exclusively for matrix diagnostics They only should be activated after consultation with the manufacturer Otherwise an increased traffic of data might limit the performance of the CPU board INF Activate information messages in Syslog default NO NOT Activate notification messages in Syslog default YES WAR Activate warning messages in Syslog default YES Syslog ERR Activate error messages in Syslog default YES Activate the modified network parameters by doing a restart Consult your system administrator before modifying the network parameters Otherwise unexpected results and failures can occur in combination with the netw
102. its is required Proceed as follows 1 Select the new CPU in the list CPU Devices 2 Select one or more extenders in the list Extender available 3 Perform the assignment by pressing the button gt To assign all available extenders to the CPU press the button gt gt The assignments are displayed in the list Extender assigned 4 Confirm the assignment by pressing the button Apply In order to remove an extender assignment proceed as follows 1 Select a CPU in the list CPU Devices 2 Select one or more extenders in the list Extender assigned 3 Remove the assignment with the button lt To remove all existing assignments press the button lt lt 4 Confirm the removal with the button Apply Pos 69 806 IHSE zz_Layout Seitenumbruch 8 mod_1348581820516_0 doc 69462 1 Configuration 2013 08 14 115 Pos 70 806 IHSE Konfiguration 480_Konsolen Einstellungen 480 xx Konsolen Einstellungen 7 mod_1309938518774_6 doc 53236 2 1 5 8 Console Settings You have the possibility to perform the following console settings Pos 71 806 IHSE Konfiguration 480_Konsolen Einstellungen 480 xx CON Devices 7 mod_1309938548274_6 doc 53254 3 1 5 8 1 CON Devices New CON devices are created in this menu including access rights and assignment to extenders You have the following possibilities to access the menu You can select between the following settings Field Selection Description
103. keyboards Certain keyboards with additional functions may require custom firmware to operate Keyboards with an integral USB Hub Mac keyboards e g are also supported Mouse Compatible with most 2 button 3 button and scroll mice Other USB HID devices The proprietary USB emulation also supports certain other USB HID devices such as specific touch screens graphic tablets barcode scanners or special keyboards Support cannot be guaranteed however for every USB HID device Only two USB HID devices are supported concurrently such as keyboard and mouse or keyboard and touch screen A hub is allowed but it does not increase the number of HID devices allowed To support other USB non HID devices such as scanners web cams or memory devices choose our devices with transparent USB support Pos 122 806 IHSE Technische Daten Schnittstellen RJ45 Netzwerk 7 mod_1309942049133_6 doc 53692 3 1 Draco tera 180 2013 08 14 7 1 3 RJ45 Network The communication of the Cat X devices requires a 1000BASE T connection The cabling has to be done according to EIA TIA 568 B 1000BASE T with RJ45 connectors at both ends All of the four wire pairs are used in both directions The cabling is suitable for a full duplex operation For the cable connection to a source computer CPU a crossed network cable cross cable has to be used Pos 123 806 IHSE Technische Daten Schnittstellen RS 232 seriell 7 mod_130994212
104. lectable Hot Key exemplary In order to set a freely selectable Hot Key e g 2x lt Space gt use the following keyboard sequence lt current Hot Key gt lt c gt lt 0 gt lt Space gt lt Enter gt Set Hot Key for direct OSD Access When setting a second Hot Key next to the Hot Key for standard functions this Hot Key can be exclusively used for opening the OSD directly In order to select a Hot Key from the Hot Key table for opening OSD directly use the following keyboard sequence lt current Hot Key gt lt f gt lt Hot Key code gt lt Enter gt In order to select a freely selectable Hot Key e g 2x lt Space gt for opening OSD directly use the following keyboard sequence lt current Hot Key gt lt f gt lt 0 gt lt Space gt lt Enter gt Reset Hot Key In order to set a Hot Key back to default settings of the extender press the key combination lt Right Shift gt lt Del gt within 5 s after switching on the CON unit or plugging in a keyboard Pos 44 806 IHSE Konfiguration 480_Ansteuerung 480 xx Ansteuerungsoptionen 7 mod_1309936958868_6 doc 52902 2 1 Configuration 2013 08 14 55 5 2 Control Options The Draco tera contains an internal CPU that allows you to control all functions from any console without the need for an external CPU or media control You have the following possibilities to access the Draco tera for configuration and operat
105. ll 480 xx 7 mod_1309944397665_6 doc 54058 2 1 9 7 Blank Screen 1 2 3 1 2 3 3 Rear View Front View Diagnosis Possible Reason Measure Switching to a CPU Port without active Source computer CPU Switching to a CPU Port with an active source computer CPU Monitors remains dark after switching operation Connection of a console with a CON port or connection of a CPU to a CPU port not established correctly Check connections regarding CON and CPU ports at the matrix LED 1 on or LED 2 off Connections CON unit matrix and CPU unit Check connecting cables and connectors No cable cable break CPU CON unit offline CPU CON unit connected to the wrong port LED 3 off Power supply Check power supply units and the connection to the power network Pos 170 806 IHSE Technische Unterst tzung ATB_Technische Unterst tzung 5 mod_1278579487089_6 doc 42650 122 1 Technical Support 2013 08 14 201 10 Technical Support Prior to contacting support please ensure you have read this manual and then installed and set up your Draco tera as recommended 10 1 Support Checklist To efficiently handle your request it is necessary to complete our checklist for support and problem cases Download Keep the following information available before you call Company name phone number and email Type and serial number of the device see bottom of device Dat
106. mbruch 8 mod_1348581820516_0 doc 69462 1 Configuration 2013 08 14 97 Pos 62 806 IHSE Konfiguration 480_Benutzereinstellungen 480 xx Benutzereinstellungen 7 mod_1309938277711_6 doc 53160 2 1 5 5 User Settings You have the possibility to configure the following user settings Pos 63 806 IHSE Konfiguration 480_Benutzereinstellungen 480 xx User 7 mod_1309938316977_6 doc 53178 3 1 5 5 1 User New users and their user settings and permissions are set in this menu You have the following possibilities to access the menu You can select between the following settings Field Selection Description Name Text User name case sensitive Password Text User password case sensitive Repeat Password Text Repeat user password case sensitive activated Access permission via FTP This setting is necessary for file access from the Java tool or any web browser FTP deactivated Function not active default activated User has user rights Permission to switch consoles to CPUs in Extended Switching according to the CON or User ACL Power User deactivated Function not active activated Permission to switch any console to any CPU in Extended Switching Super User deactivated Function not active activated Permission for system configuration and all switching operations User has administrator rights This setting is required for an online connection with
107. mod_1345795904852_6 doc 68081 3 4 The following KVM extenders are released for the use with the Draco tera The use of KVM extenders with upgrade modules or USB 2 0 modules does not limit the operation with the Draco tera 7 3 1 KVM Extenders with Cat X Connection K477 Series Type Description L477 1SHC Draco tera KVM CPU Unit Single Head 2x USB HID R477 1SHC Draco tera KVM CON Unit Single Head 2x USB HID L477 1SECA Draco tera KVM CPU Unit Single Head Analog Audio 2x USB HID and 2x USB 2 0 R477 1SECA Draco tera KVM CON Unit Single Head Analog Audio 2x USB HID and 2x USB 2 0 L477 1SECD Draco tera KVM CPU Unit Single Head Digital Audio 2x USB HID and 2x USB 2 0 R477 1SECD Draco tera KVM CON Unit Single Head Digital Audio 2x USB HID and 2x USB 2 0 L477 1STC Draco tera KVM CPU Unit Single Head 2x USB HID 4x USB 2 0 R477 1STC Draco tera KVM CON Unit Single Head 2x USB HID 4x USB 2 0 L477 2S4C Draco tera KVM CPU Unit Dual Head 4x USB HID R477 2S4C Draco tera KVM CON Unit Dual Head 4x USB HID L477 SHCV Draco tera KVM CPU Unit Single Head DVI I input VGA 2x USB HID R477 SHCV Draco tera KVM CON Unit Single Head DVI I Input VGA 2x USB HID K474 Series Type Description L474 BSHC Draco tera KVM CPU Unit Single Head 2x USB HID R474 BSHC Draco tera KVM CON Unit Single Head 2x USB HID L474 BSHCV Draco tera KVM CPU Unit Single Head DVI I input VGA 2
108. n_Kontrolle 480_Multi Screen Kontrolle 8 mod_1360600488238_6 doc 71072 2 1 6 5 Multi Screen Control The function Multi Screen contains a switching of the USB HID signal between different statically connected sources computer CPU within a CON Device and can be performed in two different ways Switching via Mouse The switching of the USB HID signal can be made by a movement of the mouse pointer beyond the edge of the current display to a neighboring display according to the configuration see Chapter 5 8 7 Page 135 In order to perform a switching operation via movement of the mouse pointer proceed as follows 1 Move the mouse pointer to that edge of the display which borders vertically or horizontally to the neighboring display 2 Move the mouse pointer beyond the edge of the display The mouse pointer will appear on the respective position at the target display The switching operation has been performed and the USB HID signal will be now available at the target display Switching via Keyboard The switching of the USB HID signal can be made by the use of keyboard commands next to the mouse movement configuration see Chapter 5 8 7 Page 135 Draco tera 172 2013 08 14 In order to perform a switching operation via keyboard command proceed as follows 1 Start Command Mode with the Hot Key see Chapter 5 1 Page 53 2 Select the target display by pressing the respective key on the numeric pad of
109. nction see Chapter 3 9 Page 38 for the monitoring of the update if unlocked via license key Ensure implicitly that all USB 2 0 extenders are only connected to the provided ports fixed ports before you start the matrix update A non observance will have a negative influence on the stability of the update Configuration 2013 08 14 149 Performing the Update Take the following steps in order to be prepared for the matrix update 1 Select Administration gt Update Matrix Firmware in the task area All updateable components of the matrix will be automatically selected and highlighted in green Menu Administration Update Matrix Firmware 2 Start the update by pressing the button Update in the appearing pop up window 3 Restart the Matrix after the update by pressing the button Restart matrix in the lower part of the working area For a safe initialisation of the matrix a cold start power cycle is recommended Draco tera 150 2013 08 14 5 11 2 Extender Update The firmware of the extenders connected to the matrix can be updated in this menu You have the following possibilities to access the menu Preparation Take the following steps in order to be prepared for the extender update 1 Save the matrix configuration externally see Chapter 5 9 4 Page 144 Open Extras gt Options in the menu bar and insert in the setting Firmware Directory the directory from which the update files shoul
110. nection status of the own console Example View Extender OSD The following information is shown in the OSD menu Field Description CON Name of the own console CPU Name of the currently connected CPU ACCESS Full Access The own console has a KVM connection to the displayed CPU Video Access The own console has a video only connection to the displayed CPU Private Mode The own console has a Private Mode connection to the displayed CPU not connected The own console is not connected to a CPU SHARED x device s shows the exact number of devices that also have a connection to the current CPU of the own console e g 3 devices If the field remains empty there only exists the own connection to the current CPU Description 2013 08 14 31 If the options Mouse Connect or Keyboard Connect see Chapter 5 4 4 Page 86 are used the name of the console with keyboard mouse control will be displayed at those consoles that do not have K M control at the moment The console is displayed in yellow color under Access Pos 26 806 IHSE Beschreibung Status Netzwerk Status 480 xx 7 mod_1309935505711_6 doc 52680 3 1 3 7 4 Network Status The current network configuration is shown in this menu You have the following possibilities to access the menu The following information is shown in this menu Field Description DHCP Information if the network settings are applied dynamically Display
111. nents and equipment 1 2 2 3 4 Video Matrix 1 Video source e g SDI camera 2 Interconnect cable 3 Draco tera matrix 4 Video sink e g monitor Pos 40 806 IHSE Installation Installationsbeispiele 480 xx Parallelbetrieb Stacking 7 mod_1309936438040_6 doc 52846 3 1 Draco tera 50 2013 08 14 4 3 3 Parallel Operation Stacking If you have special configurations especially at installations with several monitors per work station or additional support of USB 2 0 transmission paths the number of connectable CPUs and consoles can be increased by a parallel operation stacking of several Draco tera devices One of the Draco tera matrices has to be defined as the master matrix all the others have to be configured as slave matrix and the IP address of the master matrix has to be entered in the field Master IP Address see Chapter 5 4 1 Page 75 They have to be connected to the master matrix via network connector RJ45 of the CPU board The option Enable LAN Echo has to be activated at the master matrix see Chapter 5 4 1 Page 75 If a switching command is done in the OSD the slave matrices will also switch automatically Switching of stacked devices might be delayed by several seconds 1 2 3 4 6 3 7 5 8 Parallel Operation Stacking Installation 2013 08 14 51 1 Dual Head source computer CPU 2 CPU unit 3 Interconnect cable 4 Draco tera matrix master matrix
112. ntal OSD position a prefixed minus describes the orientation to the right edge of the monitor e g 2 means 2 x 10 20 pixels of distance to this edge When setting a vertical position a prefixed minus describes the orientation to the bottom edge of the monitor If the function Update Connections is deactivated the Extender OSD only appears when switching via OSD You have the following possibility to access the menu Draco tera 124 2013 08 14 OSD Select Configuration gt EXT Units in the main menu Menu Configuration EXT Units In order to change the Extender OSD settings proceed as follows 1 Select the console extender in the list EXT Units whose Extender OSD settings has to be adjusted 2 When confirming the selection by pressing the key lt Enter gt the respective console extender will be enabled for editing Configuration 2013 08 14 125 Java Tool Select Definition gt EXT Units in the task area Menu Definition EXT Units In order to change the Extender OSD settings proceed as follows 1 Select the console extender in the list EXT Units whose Extender OSD settings has to be adjusted 2 Open the tab Extender OSD Data 3 Adjust the desired settings and confirm your changes by pressing the button Apply Pos 75 806 IHSE zz_Layout Seitenumbruch 8 mod_1348581820516_0 doc 69462 1 Draco tera 126 2013 08 14 Pos 76 806 IHSE Konfiguration 480_Konsolen
113. nual describes how to install your Draco tera how to operate it and how to perform trouble shooting 1 2 Validity This manual is valid for all devices listed on the front page The product code is printed on the base of the devices 1 3 Cautions and Notes The following symbols are used in this manual This symbol indicates an important operating instruction that should be followed to avoid any potential damage to hardware or property loss of data or personal injury This symbol indicates important information to help you make the best use of this product This symbol indicates best practice information to show recommended and optimal ways to use this product in an efficient way Pos 2 806 IHSE Zu diesem Handbuch ATB_Schreibweisen 7 mod_1309932297321_6 doc 52440 2 4 1 4 Spellings You can find the following spellings in the manual Spelling Description lt key gt Description of a key on the keyboard lt key gt lt key gt Press keys simultaneously lt key gt lt key gt Press keys successively 2x lt key gt Press key 2x in quick succession cf mouse double click Menu item Description of a menu item in the software Menu item gt Menu item Select menu items successively Bold print Description of terms that are used in the device software Pos 3 806 IHSE Sicherheitshinweise 480_Sicherheitshinweise 7 mod_1310643167940_6 doc 54240 1 1 Safety Instructions 2013 08 1
114. o not attempt to open or repair a power supply unit Do not attempt to open or repair the Draco tera There are no user serviceable parts inside Please contact your dealer or manufacturer if there is a fault Pos 4 806 IHSE Beschreibung UEB_Beschreibung 5 mod_1278573379151_6 doc 41546 1 1 Draco tera 10 2013 08 14 3 Description Pos 5 806 IHSE Beschreibung Verwendungszweck 480 xx 7 mod_1309932919008_6 doc 52458 2 1 3 1 Application The Draco tera matrix is used to establish connections from consoles monitor keyboard mouse and other peripheral devices to various sources computer CPU In a maximum configuration up to 288 independent ports can be defined and switched either as a console or a CPU The Draco tera matrix is mainly specified for the use with extenders that are able to transmit video KVM and USB 2 0 signals But it can be also run as a video matrix The connection between the matrix and the peripheral devices such as KVM extenders or video sources can be made by Cat X fiber or coaxial cables The matrix serves as a repeater Thus the matrix can be run at a maximum distance of 10 km from the consoles and 10 km from the sources Pos 6 806 IHSE Beschreibung Zugriffsm glichkeiten 480 xx 7 mod_1309933105946_6 doc 52477 2 1 3 2 Access Options You have the following options to access the Draco tera for configuration and operation Access Option Symbol OSD
115. ollowing additional access options via Java Tool via serial interface A connection to common media controls is possible too The following part shows typical exemplary installations of the Draco tera Pos 38 806 IHSE Installation Installationsbeispiele 480 xx KVM Matrix 7 mod_1309936183571_6 doc 52810 3 1 Draco tera 48 2013 08 14 4 3 1 KVM Matrix In Single Head mode up to 288 ports can be used either as an input or as an output port depending on components and equipment At the same time there is a non blocking access for all users i e user access is not limited by the activities of another user 1 2 3 5 3 6 4 Single Head KVM Matrix 1 Source computer CPU 2 CPU unit 3 Interconnect cable 4 Draco tera matrix 5 CON unit 6 Console monitor keyboard mouse If you have a Single Head console you can also get access to a Dual Head or Quad Head CPU for example However control is only possible at monitor 1 Any signal source can be switched to any number of monitors that will show the video signal at the same time In addition to that even optional audio can be switched Pos 39 806 IHSE Installation Installationsbeispiele 480 xx Videomatrix 7 mod_1309936380821_6 doc 52828 3 1 Installation 2013 08 14 49 4 3 2 Video Matrix If you use the Draco tera as a video matrix up to 288 input ports can be switched to up to 288 output ports depending on compo
116. on are shown These storage locations can be overwritten Draco tera 140 2013 08 14 The storage location that has to be overwritten by the current configuration must be selected explicitly Afterwards the current configuration will be saved to this storage location and will be immediately shown in the menu The previously saved configuration that has been saved to this storage location is deleted OSD You have the possibility to save the created configuration within eight storage locations in the matrix File 1 File 8 Additionally a configuration can also be saved as default configuration 1 Select Configuration gt Save As in the main menu 2 Select the required storage location File 1 File 8 or Default Menu Configuration Save as Configuration 2013 08 14 141 Java Tool To save the configuration into the internal matrix memory proceed as follows 1 Select File gt Upload in the menu bar 2 Enter the IP address of the matrix your user name and your password and confirm your inputs with the button Next 3 Select the storage location in that the configuration has to be saved default or config01 config08 and confirm with the button OK Menu File Upload Pos 83 806 IHSE zz_Layout Seitenumbruch 8 mod_1348581820516_0 doc 69462 1 Draco tera 142 2013 08 14 Pos 84 806 IHSE Konfiguration 480_Speichern und Laden von Konfigurationen 480 xx Laden von Kon
117. onnection 2 only with HDMI CON Units with available connection for a local source and a redundant interconnection lt Hot Key gt lt l gt lt Enter gt Switch to local source computer CPU only with HDMI CON Units with available connection for a local source lt Hot Key gt lt h gt lt w gt lt Enter gt USB HID Ghosting Writing the device descriptions of the input devices connected to the CON Unit into the CPU Unit Activating the emulation in the CPU Unit lt Hot Key gt lt h gt lt e gt lt Enter gt Activating the emulation of already stored device descriptions in the CPU Unit lt Hot Key lt h gt lt d gt lt Enter gt Deactivating the emulation of active device descriptions in the CPU Unit The input devices connected to the CON Unit will be now passed transparently to the source computer CPU lt Hot Key lt h gt lt r gt lt Enter gt Deactivating the emulation of active device descriptions in the CPU Unit Deleting the descriptions out of the CPU Unit The input devices connected to the CON Unit will be now passed transparently to the source computer CPU Matrix Keyboard Command Description lt Hot Key gt lt o gt Open OSD lt Hot Key gt lt m gt lt o gt Open OSD of the master matrix in a cascaded environment Draco tera 178 2013 08 14 Keyboard Command Description lt Hot Key gt lt s gt lt o gt Open OSD of the sub ma
118. or CPU access paste function 8 Set user favorites for OSD access 9 Press the button Apply to save the new user settings You can select between the following keyboard commands Function Keyboard Command Add CPU to list Full Access lt F gt Add CPU to list Video Access lt V gt Add CPU to list No Access lt N gt Pos 64 806 IHSE Konfiguration 480_Benutzereinstellungen 480 xx Favoritenliste Benutzer 7 mod_1321429770828_6 doc 54740 3 1 5 5 2 Favorite List Users Individual favorite lists of CPUs that have to be switched frequently can be created for different users in this menu A favorite list can contain up to eight different CPUs The switching of the favorites is done via Hot Key using the keyboard see Chapter 6 1 1 Page 157 You have the following possibilities to access the menu Configuration 2013 08 14 101 OSD Select Assignments gt User Favorites in the main menu Menu Assignments User Favorites To create a favorite list for you own user proceed as follows 1 Select successively these CPUs from the list CPU Devices that have to be moved to the favorite list By pressing the key lt a gt a CPU device will be moved to the favorite list and it will be removed by pressing lt r gt 2 The order of the CPU devices within the favorite list can be changed by pressing the keys lt gt and lt gt 3 Press the button Save to save the settings Draco ter
119. ork Draco tera 92 2013 08 14 OSD Select Configuration gt Network in the main menu Menu Configuration Network You can select between the following buttons Button Function Cancel Reject changes Save Save changes Configuration 2013 08 14 93 Java Tool Select System gt Network in the task area Menu System Network Pos 60 806 IHSE Konfiguration Systemeinstellung 480 xx Datum und Uhrzeit 7 mod_1309938224352_6 doc 53140 3 1 Draco tera 94 2013 08 14 5 4 6 Date and Time Date and Time are set in this menu based on Simple Network Time Protocol SNTP You have the following possibilities to access the menu You can select between the following settings Field Selection Description activated Enable network time server synchronization SNTP Client deactivated Function not active default SNTP Server Byte Input of the SNTP server IP address default 000 000 000 000 Time Zone Region Set your specific time zone Month 1 12 Enter month Date 1 31 Enter date Year 1 99 Enter year Day 1 7 Enter day of the week Hours 0 23 Enter hour Minutes 0 59 Enter minute Seconds 0 59 Enter second Date format according to the English notation Configuration 2013 08 14 95 OSD Select Configuration gt Date Time in the main menu Menu Configuration Date Time In order to configure a time server
120. previous CPU 1 Start Command Mode with the Hot Key For control the LEDs Shift and Scroll flash at the keyboard if Command Mode is activated 2 Press the key lt p gt of your keyboard At the same time the Command Mode is closed and the console is connected to the previous CPU with complete control If you switch to a previous CPU that was connected with Video Access before you will be connected to this CPU with full KVM access You can only switch to not used and allowed CPUs with the Hot Keys The options Force Connect and Force Disconnect as well as the restrictions of the User ACL and CON ACL are taken into account Hot Keys are only supported if neither Enable User Login nor the Enable User ACL is selected and the user is logged in the OSD Disconnect current Connection 1 Start Command Mode with the Hot Key For control the LEDs Shift and Scroll flash at the keyboard if Command Mode is activated 2 Press the key lt Backspace gt of your keyboard The Command Mode is closed and the console is disconnected from the previous connected CPU Pos 98 806 IHSE zz_Layout Seitenumbruch 8 mod_1348581820516_0 doc 69462 1 Operation 2013 08 14 159 Pos 99 806 IHSE Betrieb Bedienung ber HotKeys 480 xx Scan Modus 7 mod_1309940746290_6 doc 53508 3 1 6 1 2 Scan Mode The Scan Mode offers the possibility to show video signals of the different CPU favorites fast and without delay and off
121. r Information Technology Equipment EN 55022 2006 A1 2007 Class A EN 55024 1998 A1 2001 A2 2003 This declaration certifies the conformity to the specified directives but contains no assurance of properties The safety instructions and installation guidelines noted in this manual shall be considered in detail Compliance with the specifications for cable lengths and types is mandatory Manufacturer IHSE GmbH Maybachstrasse 11 88094 Oberteuringen Deutschland Oberteuringen 26 January 2010 The Management Use in a Domestic Environment This is a Class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures Certificates 2013 08 14 203 11 2 North American Regulatory Compliance This equipment has been found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense
122. required the use of the possibilities that extended switching offers see Chapter 6 3 Page 164 When switching USB 2 0 connections you should wait until the process of registration of the USB 2 0 devices has been completed before you switch to the next CPU ca 5 15 s Otherwise the stability of the USB 2 0 connection can be affected negatively Operation 2013 08 14 173 Pos 108 806 IHSE zz_Layout Seitenumbruch 8 mod_1348581820516_0 doc 69462 1 Pos 109 806 IHSE Betrieb Schaltmakros 480 xx 7 mod_1324449399385_6 doc 56882 2 1 6 7 Presets Predefined macros to switch the matrix without loading a new configuration can be created and activated in this menu You have the following possibility to access the menu Select Control gt Presets in the task area Menu Control Presets To create a new switch macro proceed as follows 1 Open a new switch macro by pressing on the symbol New in the right column of the working area You are asked if the existing connections shall be taken over for the new switch macro 2 Set the desired switching operations in the corresponding columns Full Access Video Only or Private Mode by using a double click on the respective selection box or use the function for a disconnect Disconnect CPU Draco tera 174 2013 08 14 3 Save the created switch macro by clicking the symbol Save in the right column of the working area A save dialog will be opened 4
123. rity Messages of a defined severity will be filtered Host Messages of a defined host will be filtered Message Messages with defined text parts will be filtered Filter options are not valid within the locally stored log files Draco tera 40 2013 08 14 Recording Function All messages shown in the Syslog are equipped with various recording functions In order to store the messages shown in the Syslog filtered or unfiltered press the button Save trace The messages will be stored in a txt file In order to remove the messages shown in the Syslog press the button Clear trace In order to stop recording the messages press the button Pause In order to continue press the button again Pos 31 806 IHSE Beschreibung SNMP 480 xx 8 mod_1352794857131_6 doc 69602 2 1 3 10 SNMP When using the SNMP function all function critical and safety critical parts of the matrix can be monitored and their status can be queried This function complies with a RFC 1157 conformal standard When using SNMP monitoring a dedicated network for reasons of access security is strongly recommended You have the following possibilities to configure the SNMP monitoring Description 2013 08 14 41 OSD In order to activate the SNMP agent proceed as follows 1 Select Configuration gt SNMP in the main menu Menu Configuration SNMP 2 Set the option Enable to Y Yes under SNMP Agent By activating
124. roblemfall Externe St rung 480 xx 7 mod_1309944289555_6 doc 54021 2 1 9 1 External Failure Diagnosis Possible Reason Measure Matrix cannot be started anymore Fuse at the standard appliance outlet Check fuse Pos 161 806 IHSE Hilfe im Problemfall Bildst rung 480 xx 7 mod_1309944461727_6 doc 54076 2 1 9 2 Video Interference Diagnosis Possible Reason Measure Opening the OSD not possible No OSD jumper set Set jumper 11 on the CON unit Incorrect video display Cable connection disturbed Check the connection length and quality of the interconnect cable to the units Pos 162 806 IHSE zz_Layout Seitenumbruch 8 mod_1348581820516_0 doc 69462 1 Draco tera 198 2013 08 14 Pos 163 806 IHSE Hilfe im Problemfall L fterst rung 480 xx 7 mod_1309944511868_6 doc 54095 2 1 9 3 Malfunction of Fans Diagnosis Possible Reason Measure Fans only run under full load Communication to fan tray is disturbed Removal and und reinstallation of the fan tray Swap both fan trays to the other slot Restart the matrix Fans do not run LED OK on Fans defective Contact your dealer Fans do not run LED OK off Power supply Check power supply and power connection Pos 164 806 IHSE Hilfe im Problemfall St rung der Netzteile 480 xx 7 mod_1309944565727_6 doc 54114 2 1 9 4 Malfunction of Power Supply Units Diagnosis Possible Reason Meas
125. s empty free configuration K480 048 Draco tera matrix with 48 ports empty free configuration Pos 10 806 IHSE Beschreibung Zubeh r 480 xx 7 mod_1309934367915_6 doc 52531 2 1 3 5 Accessories Part No Description 480 B1 Java Tool Extended Switching Presets 480 B2 480 B1 API 480 B3 SNMP Syslog 480 B4 Cascading stacking 480 B5 Multi Screen Control 480 C8 Draco tera Cat X I O board 480 S8 Draco tera fiber I O board Single mode 480 V8 Draco tera fiber I O board Single mode 3 125 Gbit s 480 SDI16 Draco tera I O board video 480 X8 Draco tera fiber I O board empty free configuration 480 CTRL Draco tera CPU board 459 1C Cat X GBIC for the use with Draco tera 459 1S Single mode GBIC for the use with Draco minor major tera 459 1V Single mode GBIC for the use with Draco tera 3 125 Gbit s 459 2FT Single mode GBIC transmitter dual unidirectional for the use with Draco tera HD SDI 459 3FT Single mode GBIC transmitter dual unidirectional for the use with Draco tera 3G SDI 459 2BT Coax GBIC transmitter dual unidirectional for the use with Draco tera HD SDI Description 2013 08 14 13 Part No Description 459 3BT Coax GBIC transmitter dual unidirectional for the use with Draco tera 3G SDI 459 2FR Single mode GBIC receiver dual unidirectional for the use with Draco tera HD SDI 459 3FR Single mode GBIC receiver dual unidirec
126. s gt Matrix Firmware in the task area Menu Status Matrix Firmware 2 In order to read out the firmware status and store it locally file extension dtf select Matrix gt Save Firmware Status to File 3 In order to read out the overall status of the matrix and store it locally file extension zip select Matrix gt Save Status to File or press the respective button in the symbol bar The various modules can expanded and retracted in the column Name by clicking with the left mouse button on the plus or minus symbols By clicking on the plus resp minus symbol in the upper right corner of the working area you can expand and retract all module information with one click on the left mouse button Draco tera 36 2013 08 14 3 7 6 Firmware Status Extender The current firmware status of the connected extenders is shown in this menu You have the following possibility to access the menu The following information is shown in this menu Field Description Name Description of the firmware Type Description of the extender module Ports Number of ports Cur Version Description of the current firmware version Cur Date Date of the current firmware version Select Status gt EXT Firmware in the task area Menu Status EXT Firmware Pos 28 806 IHSE Beschreibung Funktion Trace 480 xx 7 mod_1309935652618_6 doc 52718 2 1 Description 2013 08 14 37 3 8 Trace Function All e
127. s are imported in this menu To import proceed as follows 1 Select File gt Import in the menu bar 2 After opening the menu select the list to import Extender CPU Console or User 3 Select the directory of the list to import 4 Confirm the import with the button Finish Menu File Import Pos 91 806 IHSE Konfiguration 480_Firmware Aktualisierung 480 xx Firmware Aktualisierung 7 mod_1313482000731_6 doc 54542 1 Draco tera 148 2013 08 14 5 11 Firmware Update 5 11 1 Matrix Update The firmware of the matrix can be updated in this menu You have the following possibility to access the menu Java Tool Only use computers to update the matrix that are self sustaining and not integrated in the KVM extender matrix setup Ensure that the computer used for the update is not set into stand by mode or sleep mode during the update Ensure that your configuration has been saved externally before you will start the update For reasons of network stability an update via WLAN is not recommended Preparation Take the following steps in order to be prepared for the matrix update 1 Save the matrix configuration externally see Chapter 5 9 4 Page 144 2 Open Extras gt Options in the menu bar and insert in the setting Firmware Directory the directory from which the update files should be standardly sourced 3 Put all hot spare boards into the matrix 4 Activate the Syslog fu
128. s the use of multi head consoles 3 Select in the field Arrangement the respective display arrangement that is available at the CON Device you want to configure 1 x 4 or 2 x 2 The fields for the configuration of the individual displays will be arranged accordingly 4 Select one or more control displays within the CON Device by setting the function Control auf Y in the respective display field Control displays are referred to the extender units within the Multi Screen Control that are connected to keyboard and mouse 5 When using the function Owner you can determine which control display is permitted for USB HID switching to the different displays Select that display from the list In order to make a display accessible for all neighboring control displays set the function Owner to shared 6 Use the function Frame to configure a red frame that shows the current display with mouse control after the expiration of a selectable timer The frame to fade in can be individually activated by using a timer gt 0 seconds Pos 80 806 IHSE Konfiguration 480_Speichern und Laden von Konfigurationen 480 xx Speichern und Laden von Konfigurationen 7 mod_1309938757899_6 doc 53292 2 1 Configuration 2013 08 14 139 5 9 Saving and Loading of Configurations You have the possibility to set the following administration of configurations Pos 81 806 IHSE Konfiguration 480_Speichern und Laden von Konfigurationen 480 xx Zwischen
129. speichern von Konfigurationen 7 mod_1309945736118_6 doc 54172 3 1 5 9 1 Active Configuration You have the following possibility to access the menu Select Configuration gt Save in the main menu By selecting this menu item the active configuration of the matrix is saved to the permanent matrix memory By default the last configuration that has been saved in this way will be restored after a restart of the matrix Changing configurations or saving them blocks the matrix memory and leads to a freeze of all OSD menus for a few seconds The switching connections are not affected by this freeze If you select Auto Save within the system settings an additional automatic saving of the configuration will be performed periodically see Chapter 5 3 2 Page 72 Pos 82 806 IHSE Konfiguration 480_Speichern und Laden von Konfigurationen 480 xx Speichern von Konfigurationen intern 7 mod_1309938789321_6 doc 53310 3 1 5 9 2 Saving of Configurations internal In this menu the current matrix configuration to predefined storage locations is saved However it does not replace the buffering of configuration see Chapter 5 9 1 Page 139 You have the following possibilities to access the menu In Active the name and detailed information of the current configuration are shown This configuration can be saved now In Default and File 1 to File 8 the name and the detailed information of the respective saved configurati
130. ssibilities to access the menu Configuration 2013 08 14 105 OSD Select via Configuration gt User Macros in the main menu the user for which a user macro has to be created Menu Configuration User Macros In order to create a macro for the selected user proceed as follows 1 Select in the field Key that one 1 16 for which a macro has to be created 2 Select the respective place on the list 1 16 of the key that has to be set with a macro key 3 Select for the marked place on the list a macro command in the field Macro Data 4 Set the necessary parameters P1 and P2 e g CON Devices or CPU Devices for the selected macro command 5 Confirm your inputs by pressing the key lt Enter gt and repeat the process for further macro commands if necessary Draco tera 106 2013 08 14 Java Tool Select in the working area of menu Definition gt User the user for which macros have to be created and open the tab Macros Menu Definition User In order to create a macro for the selected user proceed as follows 1 Select in the field Key that one 1 16 for which a macro has to be created 2 Select in the column Function the commands that should be part of the macro The selection list is opened by a double click on the empty fields 3 Select in the columns P1 and P2 the respective parameters for the macro functions e g corresponding consoles and CPUs 4 Confirm your inputs
131. t Activate Online Configuration Mode This setting will be additionally shown in the lower part of the working area 2 Make any edits at the configuration and system settings and confirm them by pressing the button Apply The changes will be immediately applied 3 In order to deactivate the online mode select the menu item Matrix gt Deactivate Online Configuration Mode in the menu bar Configuration 2013 08 14 67 Options menu The use of the Java tool can be adapted and customised by editing various default settings In order to activate or change the default settings proceed as follows Select Extras gt Options in the menu bar The tab Default Settings will open The following default settings parameters can be done Option Description IP Hostname Default IP address of the matrix required for connection User Default user name required for connection Configuration Directory Default directory for configuration files Firmware Directory Default directory for update files Status Directory Default directory for the firmware status Import Export Directory Default directory for import and export files Presets Directory Default directory for macro files In order to set various font sizes for the Java tool proceed as follows 1 Select Extras gt Options in the menu bar 2 Open the tab Font 3 Select the desired font size normal or large Draco tera 68 2013 08 14
132. t Part or extender board of a CON or CPU unit with a connection to the matrix A CON or CPU unit can consist of several EXT devices Force Connect Matrix function that allows to switch with the own console to a CPU that is already used and in doing so to take keyboard and mouse control The connected console so far loses K M control but keeps video Force Disconnect Matrix function that allows to switch with the own console to a CPU that is already used and in doing so to take KVM control The connected console so far loses complete KVM control Java Tool Java based control and configuration tool for the Draco tera matrix Glossary 2013 08 14 209 Term Explanation Keyboard Connect Matrix function that allows taking over the keyboard control of an inactive console Macro Keys Programmable keys that can execute a stringing together of commands to the matrix Mouse Connect Matrix function that allows taking the mouse control of an inactive console Non Blocking Access Matrix configuration where no user can be disturbed by an activity of another user OSD Timeout Matrix function that closes the OSD automatically after a predefined period of time of inactivity Release Time Matrix function that allows a console that is connected with the same CPU to release the K M control after a predefined time Service Mode Defined maintenance condition that allows updating of extenders that are connected to the matrix
133. te the respective display for the use of the Multi Screen Control Configuration 2013 08 14 137 4 Select one or more control displays within the CON Device by setting the function Control auf Y in the respective display field Control displays are referred to the extender units within the Multi Screen Control that are connected to keyboard and mouse 5 When using the function Owner you can determine which control display is permitted for USB HID switching to the different displays Select that display from the list In order to make a display accessible for all neighboring control displays set the function Owner to shared 6 Use the function Frame to configure a red frame that shows the current display with mouse control after the expiration of a selectable timer The frame to fade in can be individually activated by using a timer gt 0 seconds Java Tool Select Assignment gt Multi Screen Control in the main menu Menu Assignment Multi Screen Control Draco tera 138 2013 08 14 In order to configure the Multi Screen Control proceed as follows 1 Select that block of 4 ports in the list of the working area which should be configured for Multi Screen Control There are only shown these blocks of 4 ports that contain at least one CON Unit 2 Activate the option Manual if the USB HID switching should only be allowed by using keyboard commands see Chapter 6 7 Page 173 The manual switching allow
134. ter 6 1 3 Page 159 In order to execute user macros the user has to be logged in at the matrix You can select between the following settings Field Selection Description Connect P1 CON P2 CPU Set bidirectional connection from console P1 to CPU P2 Connect Video P1 CON P2 CPU Set video connection from console P1 to CPU P2 Disconnect P1 CON Disconnect console P1 Logout User Logout current user Set Real CPU P1 VCPU P2 RCPU Assign a virtual CPU to a real CPU Set Virtual CON P1 RCON P2 VCON Assign a real console to a virtual console Push P1 CON The own KVM connection is forwarded to console P1 and is changed to a video only connection Function 01 16 Push Video P1 CON The video signal of the current connection KVM or video only is forwarded to console P1 The own connection remains unchanged KVM or video only Draco tera 104 2013 08 14 Field Selection Description Get P1 CON The own console gets a KVM connection to the CPU that is currently connected to console P1 The connection of console P1 is changed into a video only connection Get Video P1 CON The own console gets a video only connection to the CPU that is currently connected to console P1 The connection of console P1 remains unchanged KVM or video only P1 CON or CPU Device Name of CON or CPU device P2 CPU or CPU Device Name of CON or CPU device You have the following po
135. th four video connections RCA Cinch A not standardized plug connection for transmission of electrical audio and video signals especially with coaxial cables S PDIF A digital audio interconnect that is used in consumer audio equipment over relatively short distances SFP SFPs Small Form Factor Pluggable are pluggable interface modules for Gigabit connections SFP modules are available for Cat X and fiber interconnect cables Single Link A DVI D interface for resolutions up to 1920x1200 by signal transmission of up to 165 MPixel s 24 bit Alternative frequencies are Full HD 1080p 2K HD 2048x1080 and 2048x1152 Single Head A system with one video connection Single mode 9 single mode fiber cable Glossary 2013 08 14 207 Term Explanation S Video Y C The S Video Y C is a video format transmitting luminance and chrominance signals separately Thereby it has a higher quality standard than CVBS TOSLINK Standardized fiber connection system for digital transmission of audio signals F05 plug connection Triple Head A system with three video connections USB HID USB HID devices Human Interface Device allow for data input There is no need for a special driver during installation New USB HID device found is reported Typical HID devices include keyboards mice graphics tablets and touch screens Storage video and audio devices are not HID VGA Video Graphics Array VGA is a computer graphics
136. the Java tool Administrator deactivated Function not active Draco tera 98 2013 08 14 OSD Select Configuration gt User in the main menu Menu Configuration User You can select between the following buttons Button Function New Create a new user Edit Edit an existing user Delete Delete an existing user Cancel Reject changes Save Save changes Configuration 2013 08 14 99 Java Tool Select Definition gt User in the task area Menu Definition User You can select between the following buttons Button Function New Open a new user configuration Delete Delete an existing user Apply Create a new user account Cancel Reject changes In order to configure a user access rights for CPUs proceed as follows 1 Select a user in the list User 2 By using the right mouse button once on a CPU in one of the respective access lists Full Access Video Access and No Access two lists for selection will appear in which the respective CPU can be moved and the access rights can be changed 3 Confirm the configuration with the button Apply Draco tera 100 2013 08 14 In order to create a new user proceed as follows 1 Press the button New 2 Select a template of an existing user if applicable Choose template 3 Press the button OK 4 Set a user name 5 Set a password 6 Set general access permissions 7 Set user permissions f
137. the current configurations of the matrix at any time and so update your own applications As an additional application you can switch parallely Draco tera clones as slaves Stacking via serial network interface Pos 48 806 IHSE Konfiguration 480_Zuordnung 480 xx Zuordnung 7 mod_1309937797383_6 doc 52976 2 1 5 3 Assignment The Draco tera offers the possibility of a console specific or a CPU specific assignment The first possibility is to assign virtual CPUs to real CPUs The second possibility is to assign real consoles to virtual consoles Pos 49 806 IHSE Konfiguration 480_Zuordnung 480 xx Virtuelle CPU 7 mod_1309937891305_6 doc 53012 3 1 5 3 1 Virtual CPU You can assign virtual to real CPUs in this menu With this function the effort for switching several consoles to the same CPU can be reduced If there a several consoles connected to a virtual CPU that is assigned to a real CPU you will only have to change the real CPU once and all consoles will receive the video signal of the new CPU You have the following possibilities to access the menu Draco tera 70 2013 08 14 OSD Select Assignments gt Virtual CPU Devices in the main menu Menu Assignments Virtual CPU Devices For an assignment proceed as follows 1 Select the virtual CPU in the list Virtual Devices that has to be assigned to a real CPU 2 Press the button Edit 3 Select the CPU in the list Real Dev
138. the keyboard The switching operation will be performed and the USB HID signal will be available at the target display You can select between the following switching operations Keyboard Command Function lt current Hot Key gt lt Num 0 gt Switching of the USB HID signal to the own display CON Unit with keyboard and mouse lt current Hot Key gt lt Num 1 gt Switching of the USB HID signals to display 1 lt current Hot Key gt lt Num 2 gt Switching of the USB HID signals to display 2 lt current Hot Key gt lt Num 3 gt Switching of the USB HID signals to display 3 lt current Hot Key gt lt Num 4 gt Switching of the USB HID signals to display 4 Pos 107 806 IHSE Betrieb USB 2 0 Umschaltung 480_USB 2 0 Umschaltung 8 mod_1345794455672_6 doc 68043 2 1 6 6 USB 2 0 Switching Switching of USB 2 0 extender basically works like switching of KVM extenders The following scenarios to switch USB 2 0 extenders are possible 1 A extender unit with USB 2 0 will be created and assigned so an already existing device with existing KVM extender units see Chapter 5 7 Page 111 or Chapter 5 8 1 Page 115 2 A separate device for the extender unit with USB 2 0 will be created without assigning a KVM extender unit to that device This possibility offers a separate switching of the USB 2 0 signal see Chapter 5 7 Page 111 or Chapter 5 8 1 Page 115 The separate switching of USB 2 0 signals
139. tion 2013 08 14 89 Java Tool Select System gt Switch in the task area Menu System Switch Pos 58 806 IHSE zz_Layout Seitenumbruch 8 mod_1348581820516_0 doc 69462 1 Draco tera 90 2013 08 14 Pos 59 806 IHSE Konfiguration Systemeinstellung 480 xx Netzwerk Network 7 mod_1309938178305_6 doc 53122 3 1 5 4 5 Network The network configuration is set in this menu You have the following possibilities to access the menu You can select between the following settings Field Selection Description activated The network settings are automatically supplied by a DNS server Note If DHCP is activated and there is no physical network connection available the boot times might increase DHCP deactivated Function not active default IP address Byte Input of the IP address if DHCP is not active default 192 168 100 99 Subnet Mask Byte Input of the subnet mask in the form 255 255 255 0 if DHCP is not active default 255 255 255 0 Gateway Byte Input of the subnet mask in the form 192 168 1 1 if DHCP is not active activated LAN interface at the Draco tera activated for access via Java tool API service port 5555 API Service deactivated Function not active activated FTP server for transmission of configuration files activated FTP Server deactivated Function not active activated Syslog server for status request is active Syslog deactivated Funct
140. tional for the use with Draco tera 3G SDI 459 2BR Coax GBIC receiver dual unidirectional for the use with Draco tera HD SDI 459 3BR Coax GBIC receiver dual unidirectional for the use with Draco tera 3G SDI 459 BMB Adapter cable BNC to mini BNC to adapt regular BNC cables to mini BNC SFP 480 FAN160 Draco tera 288 160 fan tray spare part 480 FAN80 Draco tera 80 fan tray spare part 480 FAN48 Draco tera 48 fan tray spare part 480 RED160 Draco tera 288 160 plug in power supply unit spare part or redundancy 480 RED80 Draco tera 80 plug in power supply unit spare part or redundancy 480 FLTR160 Draco tera 288 160 filter pads as consumable supply 480 FLTR80 Draco tera 80 filter pads as consumable supply 480 FLTR48 Draco tera 48 filter pads as consumable supply You can find appropriate extenders or other components in Chapter 7 3 Page 184 Pos 11 806 IHSE zz_Layout Seitenumbruch 8 mod_1348581820516_0 doc 69462 1 Draco tera 14 2013 08 14 3 6 Device Views The following views of the Draco tera matrix illustrate the various available chassis types Pos 13 806 IHSE Beschreibung Ger teansichten 480 xx Draco tera 288 Port 7 mod_1309934693586_6 doc 52550 3 1 3 6 1 Draco tera 288 Port FILTER 1 2 3 4 5 6 7 OK HS FAN TRAY OK HS FAN TRAY 8 Front View Description 2013 08 14 15 1 Slot for power supply unit 1 2 Slot
141. ton Activate The opened configuration is activated and can be used now Menu File Open Pos 88 806 IHSE Konfiguration 480_Export und Import von Listen 480 xx Export und Import von Listen 7 mod_1309939181868_6 doc 53390 2 1 Draco tera 146 2013 08 14 5 10 Export and Import Options The Draco tera offers the possibility to read out available configuration lists extender CPUs consoles and users for exporting and importing again via Java tool You have the following possibilities to handle configuration lists Exported configuration lists are always saved in csv format that allows offline editing with common spreadsheet applications You have the following possibilities to export or import configuration lists Pos 89 806 IHSE Konfiguration 480_Export und Import von Listen 480 xx Export von Listen 7 mod_1309939231696_6 doc 53408 3 1 5 10 1 Export Options Configuration lists are exported in this menu To export proceed as follows 1 Select File gt Export in the menu bar 2 After opening the menu select the list to export Extender CPU Console or User 3 Select the storage location for the export file 4 Confirm the export with the button Finish Menu File Export Configuration 2013 08 14 147 Pos 90 806 IHSE Konfiguration 480_Export und Import von Listen 480 xx Import von Listen 7 mod_1309939264649_6 doc 53426 3 1 5 10 2 Import Options Configuration list
142. trix in a cascaded environment lt Hot Key gt lt Enter gt Set a KVM connection keyboard mouse and video to the selected source computer CPU lt Hot Key gt lt Space gt Set a video only connection to the selected source computer CPU lt Hot Key gt lt Left Shift gt lt Enter gt Set a Private Mode connection to the selected source computer CPU lt Hot Key gt lt Backspace gt Close the current connection of the own console lt Hot Key gt lt p gt Switch back to the previous connected source computer CPU with a KVM connection lt Hot Key gt lt 1 gt lt 16 gt lt Enter gt lt Space gt or lt Left Shift gt lt Enter gt Switch to a source computer CPU stored in the Favorite List with a KVM connection video only or Private Mode connection lt Hot Key gt lt F1 gt lt F16 gt Execute a predefined macro lt Hot Key gt lt c gt lt new Hot Key Code gt lt Enter gt Change the Hot Key according to the predefined Hot Key table lt Hot Key gt lt c gt lt 0 gt lt new Hot Key key gt lt Enter gt Define freely selectable Hot Key lt Hot Key gt lt f gt lt new Hot Key Code gt lt Enter gt Change the Hot Key for direct OSD access according to the predefined Hot Key table lt Hot Key gt lt f gt lt 0 gt lt new Hot Key key gt lt Enter gt Define freely selectable Hot Key for dire
143. ure Power supply units not locked correctly Check lock and plug in of the power supply units No power supply available Check if cables for the power supply are connected correctly Matrix cannot be started Power supply units are not switched on Check slide to switch on the power supply units Pos 165 806 IHSE Hilfe im Problemfall Netzwerkst rung 480 xx 7 mod_1309944607415_6 doc 54133 2 1 9 5 Network Error Diagnosis Possible Reason Measure Network settings are not assumed after editing Restart of the matrix not yet completed Do a restart Pos 166 806 IHSE zz_Layout Seitenumbruch 8 mod_1348581820516_0 doc 69462 1 Troubleshooting 2013 08 14 199 Pos 167 806 IHSE Hilfe im Problemfall St rung an der Matrix 480 xx 7 mod_1309944331383_6 doc 54040 2 1 9 6 Failure at the Matrix Diagnosis Possible Reason Measure Serial control impossible or only restrictedly possible Different Baud rate of CPU and matrix Adapt Baud rate in the matrix and in the CPU see Chapter 5 3 2 Page 72 Serial control via RJ45 port not possible Wrong network cable Use a crossed network cable Port definitions as USB 2 0 invalid Restart of the matrix not yet completed Do a restart Pos 168 806 IHSE zz_Layout Seitenumbruch 8 mod_1348581820516_0 doc 69462 1 Draco tera 200 2013 08 14 Pos 169 806 IHSE Hilfe im Problemfall Bildausfa
144. us Description 1 Status 1 green On Operating condition Off Operating condition 2 Status 2 red On Error indication Off Hot Swap option deactivated 3 Hot Swap blue On Hot Swap option activated Description 2013 08 14 25 Power Supply Unit Draco tera 288 160 1 2 3 Front View Status LEDs of the power supply units Pos LED Status Description 1 AC Input OK green On Operating condition 2 DC Output OK green On Operating condition Off Normal temperature 3 O T yellow On High temperature Power Supply Unit Draco tera 80 48 1 Front View Pos LED Status Description On Operating condition 1 DC Input OK green Off No power supply On Power supply unit not active Matrix is powered by second power supply unit DC Input red Off Operating condition Pos 23 806 IHSE zz_Layout Seitenumbruch 8 mod_1348581820516_0 doc 69462 1 Draco tera 26 2013 08 14 Pos 24 806 IHSE Beschreibung Status Port Status 480 xx 7 mod_1309935423961_6 doc 52661 3 1 3 7 2 Port Status The connections and the switching status between the various consoles and CPUs are shown in this menu You have the following possibilities to access the menu Java Tool The current port configuration of the Draco tera is illustrated in this menu Select Status gt Matrix View in the task area when connected to the matrix Menu Status Matrix View example 1
145. use the following sorting functions Function Keyboard Command Sort ID numbers in a descending order or in an ascending order by pressing the keyboard command twice ID lt F1 gt Sort ID names in a descending order or in an ascending order by pressing the keyboard command twice Name lt F2 gt Go to the next result in the list of results of the search field Next lt F3 gt Go to the previous result in the list of results of the search field Previous lt F4 gt Refresh the currently shown list Refresh lt F5 gt Jump between the search field and the list of results Find lt F6 gt Configuration 2013 08 14 59 Password request You have to login with administrator rights to be able to set configurations Menu Login Access to the configuration menu requires administrator rights User login is mandatory Field Input User admin Password admin By pressing the key lt F10 gt in the main menu of the OSD the login mask will be opened In order to log out a user press the key lt F10 gt again For security reasons please change the administrator password as soon as possible see Chapter 5 4 1 Page 75 Pos 46 806 IHSE Konfiguration 480_Ansteuerung 480 xx Ansteuerung via Java Tool 7 mod_1309937697743_6 doc 52938 3 1 Draco tera 60 2013 08 14 5 2 2 Control via Java Tool Requirements If you want to use the Java Tool the following requirements have to be
146. vents e g activities and switching operations of the Draco tera matrix are logged and displayed in this menu This function is used for diagnostic purposes You have the possibility to request various trace views in the menu The following information is shown in this menu Field Description Date Date stamp Time Time stamp Message Detailed description of the event Trace possibilities Select Status gt Trace IO Board in the main menu to check the events on your current I O board Select Status gt Trace Matrix to check the matrix events Pos 29 806 IHSE zz_Layout Seitenumbruch 8 mod_1348581820516_0 doc 69462 1 Draco tera 38 2013 08 14 Pos 30 806 IHSE Beschreibung Syslog Monitoring 480 xx 8 mod_1351496895799_6 doc 69482 2 1 3 9 Syslog Monitoring The complete logging of the Draco tera matrix regarding activities switching operations and the surveillance of function critical components like fans or power supply units take place in this menu You have the following possibility to access the menu In order to start Syslog Monitoring proceed as follows Select the symbol Monitoring in the symbol bar Menu Monitoring Syslog The logging of system activities starts when opening the menu Monitoring and remains active until the appropriate tab will be closed Syslog messages are transmitted via UDP Therefore port 514 within the used network should not be blocked
147. via the matrix Switching is performed between the local source and the KVM connection and can be executed via Hot Keys or via OSD If you switch to the local source the KVM connection will be automatically disconnected You have the following possibility to switch to the local source Draco tera 170 2013 08 14 OSD Select Switch in the main menu Menu CON Switch In order to switch to a local source proceed as follows 1 If you are not yet in the menu Switch of the OSD start Command Mode with the Hot Key see Chapter 5 1 Page 53 2 Press lt o gt to open OSD You will see a list of all available CPUs as a start menu 3 Switch to the CPU in the list that is called Local CPU The switching operation to the local source will be immediately performed The local source computer CPU will be only shown in the OSD if the respecitve CON Unit includes the option for a local connection Operation 2013 08 14 171 Alternatively there are the following keyboard commands available in order to switch to the local source Function Keyboard Command Switching to extender connection lt Hot Key gt lt k gt lt 1 gt lt Enter gt Switching to extender connection 2 only with redundant CON Units lt Hot Key gt lt k gt lt 2 gt lt Enter gt Switching to the local source computer CPU lt Hot Key gt lt l gt lt Enter gt Pos 106 806 IHSE Betrieb 480_Multi Scree
148. witching via a keyboard connected to a CON port and the favorites by a macro keyboard connected to a console port 2 OSD via keyboard mouse directly connected to the CPU board of the matrix via keyboard mouse connected to a CON Unit and the OSD 3 External Switching Commands via an external computer via Java tool network connection required via a media control network or serial connection required Pos 95 806 IHSE zz_Layout Seitenumbruch 8 mod_1348581820516_0 doc 69462 1 Operation 2013 08 14 157 Pos 96 806 IHSE Betrieb Bedienung ber HotKeys 480 xx UEB_Bedienung_ ber_Hotkeys 7 mod_1309939558243_6 doc 53464 2 1 6 1 Operation via Hot Keys Pos 97 806 IHSE Betrieb Bedienung ber HotKeys 480 xx Direktumschaltung 7 mod_1309940339211_6 doc 53490 3 1 6 1 1 Direct Switching The direct switching by favorites on a keyboard is the fastest possibility for a user to switch at his console between different CPUs There is a possibility to switch video keyboard and mouse or only video Direct Switching of Video Keyboard and Mouse 1 Start Command Mode with the Hot Key For control the LEDs Shift and Scroll flash at the keyboard if Command Mode is activated 2 Enter the index number of the new CPU from the list of favorites and confirm with lt Enter gt At the same time the Command Mode is closed and the console is connected to the new CPU with
149. x USB HID R474 BSHCV Draco tera KVM CON Unit Single Head IR receiver 2x USB HID Pos 134 806 IHSE Technische Daten Unterst tzte Peripherie 480 xx KVM Extender Glasfaser 7 mod_1311332022151_6 doc 54403 3 1 Specifications 2013 08 14 185 7 3 2 KVM Extenders with Fiber Connection Single Mode K477 Series Type Description L477 1SHS Draco tera KVM CPU Unit Single Head 2x USB HID R477 1SHS Draco tera KVM CON Unit Single Head 2x USB HID L477 1SHX Draco tera KVM CPU Unit Single Head 2x USB HID XV R477 1SHX Draco tera KVM CON Unit Single Head 2x USB HID XV L477 1SESA Draco tera KVM CPU Unit Single Head Analog Audio 2x USB HID and 2x USB 2 0 R477 1SESA Draco tera KVM CON Unit Single Head Analog Audio 2x USB HID and 2x USB 2 0 L477 1SEXA Draco tera KVM CPU Unit Single Head Analog Audio 2x USB HID and 2x USB 2 0 XV R477 1SEXA Draco tera KVM CON Unit Single Head Analog Audio 2x USB HID and 2x USB 2 0 XV L477 1SESD Draco tera KVM CPU Unit Single Head Digital Audio 2x USB HID and 2x USB 2 0 R477 1SESD Draco tera KVM CON Unit Single Head Digital Audio2x USB HID and 2x USB 2 0 L477 1SEXD Draco tera KVM CPU Unit Single Head Digital Audio 2x USB HID and 2x USB 2 0 XV R477 1SEXD Draco tera KVM CON Unit Single Head Digital Audio 2x USB HID and 2x USB 2 0 XV L477 1STS Draco tera KVM CPU Unit Single Head 2x USB HID 4x USB 2 0 R477 1STS Draco tera KVM

Download Pdf Manuals

image

Related Search

Related Contents

Philips MCM166 User Guide Manual  User Manual  User manual & Installation  CSXi (user manual)  Samsung WF1602WQU/YLE Užívateľská príručka  Samsung PL90 User Manual  5088_6088_7088_Productivity_Guide  Dossier de presse de Mode d`emploi  Christie Christie HD User manual  210093 Story Teller Audio File Utility User Manual Rev1.1  