PX/QX/RX Version 4.30 User Manual

image

Contents

1. 24 Ja CONEA TDN S 25 SCHEDULE ore 25 GROUP TEXT E 25 MINUTES LEFT PX250HS ONLY ccscssssscssssssssscessscsscsssssessssssssssssssssssssssssessessssssessesssesssssessessssssesseseoss 26 LATE WORK qM 26 Di4g Ile M 27 2452 06 27 EUH iR ERR ET REA 28 PRINT TEX ostro 28 PRINT HOLS Porc 28 IDENTIFY USER 28 9 8 AUCTUS 29 COPY PX ONLY e 29 C US Vic 29 ACCESS FEATURES PX 2007000 0 ees stas en sens sesenta sese 30 ADD AJUSER iecssccsvconsectesscststaccosansuassacoseesnesdescentscoesetsscoutsenescsentvecseatsensesoedssndsesesseenrachessonssensancdsscsaseseeecsnevessesenss 30 DELETE USER quo 31 DOOR UNLOCK quu 31 Seo Dyireer 32 32 APPENDIX USER AUTHORITIES eeeeee 66661606166 6 0111166 660100001181 100010 000044 0 00 0 88000000 33 APPE
2. by the engineer 171 178 Turn off output 1 to 8 the selected output must be programmed by the engineer 010 Unset system 01 Unset group where 1 to 32 020 Set system 02nnit Set group n where n 1 to 32 Status of set group n where n 1 to 32 03nn Cancel command shut down call Note that all commands except toggle are preceded with a and you must wait for the confirm tone after the before pressing Message Length Function seconds 0 8 Main message sent with all speech format alarm reports 1 8 4 Channel messages sent when the corresponding channel is active 9 6 Memo message or stored audio message 41 PX QX RX Version 4 30 User Manual Issue Appendix G System Details Number of Areas Number of keypads Number of Circuits Number of Users Contract Number Keypads Number Location 42 PX QX RX Version 4 30 User Manual Issue Circuits Number Cct 1 Description Location Cct 2 Cct 3 Cct 4 Cct 5 Cct 6 Cct 7 Cct 8 Cct 9 Cct 10 Cct 11 Cct 12 Cct 13 Cct 14 Cct 15 Cct 16 Cct 17 Cct 18 Cct 19 Cct 20 Cct 21 Cct 22 Cct 23 Cct 24 Cct 25 Cct 26 Cct 27 43 Number 28
3. The system can be programmed by the engineer to allow the manual door lock unlock option to override the schedule control 1 1 53 Door Unlock 1 1 D M Door 1 o Door 1 Door Unlock Off m Unlock On Unlock Time 000 31 PX QX RX Version 4 30 User Manual Issue Door Lockout Code 54 This option will only be available if at least one ACM is fitted to the system The locked out ACM door will remain locked and will refuse all access attempts until the lockout is removed The ACM door lockout can only be removed through this programming option The ACM door lockout will over ride any user ACM schedule permissions or otherwise immediately and for the applied duration Upon removal the ACM door will be returned to its previous state if that state still applies Proximity reader LED s will show the ACM door as locked out for the applied duration 54 Lockout An access user with supervisor authority can gain access through door with lockout enabled Door 1 Door Lockout On ACM Text Code 55 A descriptor of up to 10 characters may be entered for each ACM Refer to the appendix B for details of how to change a descriptor 32 PX QX RX Version 4 30 User Manual Issue Appendix A User Authorities All user options with the appropriate authority level are shown in the table Code Menu Option Bank Reset Guard Duress
4. 29 30 PX QX RX Version 4 30 User Manual Issue Description Location 31 32 Users Number Description Areas 1 2 3 44 PX QX RX Version 4 30 User Manual Issue Legal Disclaimer This manual was written for use with the PX QX RX system version 4 30 This manual and the PX QX RX systems described in it are copyrighted with all rights reserved This manual and the PX QX RX systems may not be copied except as otherwise provided in your system license or as expressly permitted in writing by Guardall Export of this technology may be controlled by the United States Government Diversion contrary to U S law prohibited Copyright 2008 by Guardall All rights reserved All other trademarks and service marks are the property of their respective owners Use of the PX QX RX systems and its documentation are governed by the terms set forth in your license Such use is at your sole risk The system and its documentation including this manual are provided AS IS and without warranty of any kind and GUARDALL AND ITS LICENSORS EXPRESSLY DISCLAIM ALL WARRANTIES EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE AND AGAINST INFRINGEMENT GUARDALL DOES NOT WARRANT THAT THE FUNCTIONS CONTAINED IN THE SYSTEM WILL MEET YOUR REQUIREMENTS OR THAT THE OPERATION OF THE SYSTEM WILL BE UNIN
5. 01 Unset 02 Set A 03 Reset 04 05 Engineer 1 06 Code 07 User 08 Tel Number V 10 Log Full 11 Log Cct 12 Log User 13 0 V 14 Log Date 15 Log Alarm V 16 17 A Log User 18 A Log ACM 20 3 V 7 V x V 4 V 5 5 6 6 V 6 6 6 V V 24 Holiday 25 Schedule 26 Group Text 27 Minutes Left 28 Late Work 30 Bypass 32 Chime 33 Shunt 40 Print Text 42 Print Hols 50 A User 51 Delete User 52 User 53 Door Unlock 54 Door Lockout 55 Text 71 Copy User 73 Copy A User 89 Cct Status gt lt gt lt gt lt gt lt Ds c gt D5 Be D5 D5 XS SS S x gt lt gt lt gt lt gt gt gt lt gt Ds Ds Ds Be gt l gt gt gt gt gt lt gt lt gt lt gt gt gt gt lt gt Dx Ds gt De Be gt lt SJ 95 gt gt gt f gt DK De Se Dep Se 0 X lt X S X S 1 Engineer option is not available to a user if the panel is programmed to allow the engineer to log on without user authorisation
6. Ga Guardall Version 4 30 User Manual Issue PX QX RX Version 4 30 User Manual Issue L6 GE HON Eo 2 JAAHA DI BLOA U LOD paea E E EE A 5 EVENT ae ag SSE RS ue A 5 AREAS amp SET GROUPS SPESE 5 CIRGUITS ies ol id iie Nicol Iac to eese ies td 5 USER SET GROUP AND CIRCUIT IDENTIFICATION ccccccecscesesccescevecevscecscecucecececsevevevavavscesacacecuceceavavavavavavacacacnenees 5 USER CODES eene PD UIDI e OO I OUI IR 6 OPERATOR CONTROLS AND 5 10 4 4 eene esten senten sten 6 DYSTEM KEYPADS ue IRR EGER ENT 8 NN ERE MINI Cards Fobs eene DUAL USER CODE OPERATION 5 5 2 Ur t e ded te vents USER CARD PIN OPERATION cr e ene Pa e T ee C e e S eee USING THE SYSTEM P 8 BAS YeSET sss ceeds 8 j 8 5 ets d i tti iL 8 REMOTE ASSIST ss ay iit GER ECTS 9 INGORREGT ODES 525 eei IHL WR 9 10 SETTINGFR
7. 3 Exit point where setting is completed by opening and closing the final exit circuit 4 Push button where setting is completed by pushing the external PB circuits after closing the final exit circuit Your installation engineer should advise which of the above options have been programmed on your system Setting from a keypad 12 00 Mon 27 Sep Guardall Log set programmed one group available 12 00 Mon 27 Sep and no problems or warnings to display Enter Log on set programmed 1 Workshop 2 Office Log off after set programmed 02 Set 04 Test Workshop Setting Workshop Seconds Left 005 Exit time expired Log off after set not programmed Workshop Set Setting with a Mini Keypad The mini keypad has two quick set buttons The actual areas or groups controlled N by the green and yellow buttons will depend on how the system has been programmed by the installer green button will set unset the first programmed area or set group and the yellow button will set unset the second programmed area or set group Pressing a and holding both and CE will set the first and second group or area 240 PX QX RX Version 4 30 User Manual Issue Keyswitch Radio Keyfob Setting As an alternative to setting unsetting from keypad your system may be fitted with an optional keyswitch which permits setting and
8. Det Test Fail Alarm amp Event Log messages Additional Data Usnn Usnn Area m Usnn Area User nn Circuit mmm Display Text Usnn Usnn Am Usnn Am Usnn Cctmmm PX QX RX Version 4 30 User Manual Issue C Event Description Date changed manual or auto One or more detector test circuits failed All detector test circuits tested OK detector circuit has failed to respond during a detector test Dorm Confirm Circuit nnn Cctnnn Dormitory circuit confirmed Dorm Init Circuit nnn Cctnnn Dormitory circuit first activation Download Fail GSRx GSRx Download from GSR x failed Download OK GSRx GSRx Download from GSR x OK Enc Sequence User nn Usnn Encryption sequence fail Engineer Reset Circuit nnn Cctnnn Engineer reset type circuit alarms Entry Alarm Area n An The area is not unset before the end of the entry warning period Entry Started Circuit nnn Cctnnn Entry circuit opens Expiry Date Usnn Usnn Config change User expiry date change Ext Time User nn Keypad Usnn ATM user selected a time extension Failed Auto Set User nn Area m Usnn Am Event programmer failed to auto set due to circuits in alarm Fault Radio module number RM nn Radio Module fault no response when unset The system fault response option must be programmed This option is only available in EN50131 compliant variants Fault Circuit nnn Cctnnn A Circuit short circuit when unset Fault Keypad n KPn
9. 2 The code option for some users will only be available if configured as part of the user authority 3 The time can only be changed by a user if programmed by the engineer User time changes are limited to 75 minutes 4 The bypass option is only available if at least one circuit has been programmed to allow bypass The print options are only available if a printer is connected to the system The access options are only available if an ACM is fitted to the system The schedule option is only available if programmed by the engineer NOD 33 PX QX RX Version 4 30 User Manual Issue Appendix Editing Text A number of text descriptors may be changed by an authorised user All changes to descriptors are logged Item Max Length Default User 10 User xx Set group 10 Group x Access control module 10 ACM x User Number 03 3 Smith A M 7 When a descriptor is displayed the character being edited will o be flashing this is shown as a grey character in the SN a hs diagram User Number 03 You change a character using the numeric keys and or 5 Space Smith use the and buttons to move through the text save clear move i o oo O v character set User Number 03 Smith pup PEN TIR i The allowed characters ABCDEFGHIJKLMNOPQRSTUVWXY Zabcdefghijkl
10. circuits which have not alarmed since the panel was last unset If all circuits are to be tested then select walk test then press the X button and select walk test a second time When the panel exits walk test mode either manually or automatically at the end of the test time then 1 Any fire sensor still in alarm will give a normal alarm response 2 Circuits with a 24 hour response which are still in alarm will be temporarily bypassed 3 Awarning will be displayed if any PA sensor is still in alarm If the comms test is selected then the panel will make a test call to all telephone numbers that have been programmed for test by the installation engineer 18 PX QX RX Version 4 30 User Manual Issue Engineer Code 05 The Eng option will only be available if the system is configured for user authorised engineer access This option applies to both local and remote engineer access When the Eng option is selected the system will prompt for the engineer PIN code to be entered Engi When an engineer logs to a keypad all other ngingel keypads in the system will be inoperable and the Guardall display will show Out of Service o time out 2 minutes 12 00 Mon 27 Sep Guardall Once logged on the engineer working time is limited to 8 hours PIN Code 06 All users on the system are identified by a 4 5 or 6 digit PIN code To change user PIN code log on to the keypad using your current PIN code and choose
11. enter the same user number as the first and last Copy A User PX Only Code 73 This option will only be available if at least one ACM is fitted to the system 73 A User Enter the user to copy Y here Enterthe first and last user the copy range here P To copy a single user enter the same user number as the first and last Cct Status Code 89 f When the Cct Status option is selected the circuits that on soak test bypassed isolated or shunted will be scrolled on the display 29 PX QX RX Version 4 30 User Manual lssue Access Features PX Only The access control features are only available the PX panel range Feature PX ACMs Access Users User expiry dates Challenged user option User lock out from keypad ACM Door lock unlock from keypad Programmable unlock time Programmable Aux relay time Anti pass back Access log events Access log real time print Set amp unset CD 45555 gt NS Note The panel users must be the first users in the system For example on the PX 500 users 2 200 may be access or panel users users 201 1000 can only be access users and user 1 is always the engineer The PX access control system can be configured through a security system keypad or a PC running GSR Access Guardall PX proximity cards or fobs may only be introduced to the sy
12. group Refer to appendix B for details of how to change a descriptor 25 PX QX RX Version 4 30 User Manual Issue Minutes Left PX250HS Only Code 27 This option is only available to an ATM user When an ATM user code and a non zero ATM delay period is programmed then a delay prompt will be displayed when the ATM user code is first entered f The actual unset menu will depend the ATM user authority the group descriptors 10 Minutes left Ext Time If the working time is less than 10 minutes and an extension time is programmed then the ATM user may extend the working time If the programmed ATM working time is more than 10 minutes then a warning will be given when the ATM user has 10 minutes working time left and the extend time prompt will be displayed automatically Requests to extend the time will be logged At the end of the working time the ATM user will be automatically logged off and areas that were unset by the ATM user will be automatically set If ATM user logs off without setting the ATM user authorised areas will be automatically set Late Work Code 28 The late working option will only be displayed if at least one set group is programmed with a schedule and late working has not been already selected When the late working option is selected a list of all available set groups will be displayed The late work time can be any time including times after midnight All lat
13. grouped together into a setting group Not RX16i which provides the user with a convenient way of setting and unsetting more than one area at the same time The installation company engineer will have configured your system for the appropriate number of areas and groups to comply with your specific security requirements Where more than one group is incorporated in the system a group can be configured by the installation engineer as a common group A common group will automatically set if all other areas of the system are set and will automatically unset if any one of the other areas is unset The RX16i variant does not include the set group feature If using a RX16i then all references to set groups throughout this manual should be interpreted as areas Circuits Each detector or sensor in the installation is allocated a unique circuit number The installation engineer will have programmed each circuit to respond in a certain way when the circuit is activated when the area is set and unset The way in which the circuit is programmed to respond will depend on the type of circuit and its location and purpose If a circuit is faulty the alarm response may be turned off by an authorised user This process is referred to as bypassing User Set group and Circuit Identification Each user set group circuit concentrator and access control module can be programmed with a text description PX QX RX Version 4 30 User Manual Issue User Co
14. keypad when area s are set 12 00 Mon 27 Sep Guardall 12 00 Mon 27 Sep Enter 01 Unset 04 Test Log off after unset programmed Log on unset programmed 1 Workshop Workshop 2 Office Unset Log off after unset not programmed Unsetting with Keyswitch Radio Keyfob To unset an area from a keyswitch turn the keyswitch to the unset position The area under the control of the keyswitch will immediately unset If your system is fitted with radio interface then radio Keyfob may be programmed for unsetting zd PX QX RX Version 4 30 User Manual Issue Automatic Unsetting The system may have been programmed by the installation engineer to automatically unset all or parts of the system according to a pre programmed schedule The schedule will have been programmed to take into account the normal opening time non working days and holidays Unsetting Warnings When unsetting from a keypad the user is informed on the display of any warnings e g circuits isolated or on soak The warning display will appear for approximately 4 seconds during the unsetting procedure If more than one warning exists the display will automatically scroll through the list of warnings The unset warnings 1 Bypassed circuit s the circuit must have a 24hr response Store 2 Circuit s on soak test has failed a special circuit test mode set u
15. one set group is available setting will start automatically LogOn Unset On Off If this option is on then the authorised set groups which are set will be unset when the user logs on Shunt On Off If this option is on the user has access to the shunt menu option 33 Card PIN On Off If the user is configured with the Card PIN option then BOTH the PIN code and the card must be used to log onto a keypad The PIN code and card may be used in any order This option does not apply when using an access module If Card PIN is off then a user may log onto a keypad using EITHER a PIN code or card Set group 1 max On Off A user can be programmed any combination of set groups 0 01 Master 02 Ordinary 03 Set Uns 04 Set 05 Unset Code Change Off 06 Cleaner LogOn Set Off 07 Access LogOn Unset Off 10 ATM Shunt Off 11 Log Card PIN Off 12 Bank Reset Group 1 Off 14 Guard Group 2 Off Group 32 Off 21 PX QX RX Version 4 30 User Manual Issue User Menu ACM Authority PX Only Code 5 This option will only be available if at least one ACM is fitted to the system Option Range Description Enable On Off If this option is off no further user ACM options will be displayed in this menu Level Normal The access authority of each user can be programmed Visitor Escort or Supervisor ACM 1 On Off A user can be authorised for access through any combination maximum
16. panel normally located out of sight in a secure area and at least one keypad The panel has a wide range of features which are programmed by the engineer on installation to suit the security requirements of the particular installation Some of the features may be reprogrammed edited or viewed as required by an authorised user Feature RX16i 1 PX80i 500 250 HS Max Panel Users 16 32 50 100 200 200 Max Access Users x x 1000 1000 1000 1000 Areas 4 8 8 16 32 16 Set Groups x 8 8 16 32 16 Sub systems x 4 4 8 16 8 Max Keypads 4 8 8 16 32 16 Access Modules x x 32 32 32 32 Audio Modules 2 4 8 16 32 16 Radio Modules 2 2 4 8 16 8 Max Transmitters 16 16 24 40 128 128 Tel Numbers 8 8 8 8 8 8 Schedules 2 4 32 32 32 32 Holidays x 14 14 14 14 20 Event Log Size 250 500 1000 1000 1000 2000 Access Log Size x x 1000 1000 1000 1000 Event Log The event log will record all events for example user log on times and user numbers keypad numbers setting and unsetting times alterations made to programmed settings fault conditions etc When the event log is full the oldest event will be automatically removed when the next event occurs All log events are date and time stamped and may be viewed or printed if a printer is fitted to the system Areas amp Set Groups For protection purposes the premises may be divided into a number of areas Individual areas may be
17. unsetting of a group by operating a keyswitch The keyswitch may be configured for any set mode If your system is fitted with a radio interface then a radio Keyfob may be programmed for setting Automatic Setting The system may have been programmed by the installation engineer to automatically set all or parts of the system according to a pre programmed schedule The schedule will have been programmed to take into account the normal closing time non working days and holidays The schedule may be configured for any set mode Aborting The Setting Procedure The setting procedure can be aborted at any time during the exit time by pressing on the keypad that was used to start setting logging on to any other keypad turning a keyswitch to the unset position or an appropriate radio Keyfob Setting with Warnings The system will automatically display any conditions that the user should be aware of before setting the system These conditions are described as set warnings and do not prohibit the user from setting the system in the normal way N 1 1 1 1 The set warnings include i 1 Bypassed circuit s Loading Door 2 Circuit s on soak test has failed a special circuit test mode set up Isolated by the installation engineer 3 Isolated circuit s 4 Line Fault only when setting with telephone line fault is allow
18. E NONE A call using the Dual comm PSTN route has failed PSTN Route OK NONE NONE A call using the Dual comm PSTN route was successful Remote Service GSRx GSRx Remote Service Complete Reprogrammed Reset Reset Restored Code s Rmt Auth Fail Session End Set Set Set Set Req Shunt Limit Shunt Off Shunt On Sndr Tamper Refer to table Circuit nnn User nn Area User nn Keypad m NONE User nn User nn Area User nn Group m Circuit nnn User nn Keypad m Area n User nn Circuit mmm User nn Circuit mmm NONE Refer to table Cctnnn Usnn Usnn Usnn KPm NONE Usnn Usnn Am Usnnm Cctnnn Usnn KPm An Usnn Cctmmm Usnn Cctmmm NONE 37 Item menu description plus optional number see note An area has been reset An area has been reset All codes have been restored to default Repeated attempt to log on by a remote host Encryption session end Area has been set by a user Group has been set by a user Key type circuit alarms A user requested set on a keypad dual set programmed The shunt limit for the system has been reached Shunted removed from circuit Shunt applied to circuit Panel sounder tamper PX QX RX Version 4 30 User Manual Issue Alarm amp Event Log messages Log Text Additional Data Display Text Event Description Soak Alarm Circuit nnn Cctnnn A circuit on soak test has alarmed Soak Failed Circuit nnn Cctnnn At the
19. Failed poll when unset Fault Conc nn Conc nn Failed poll when unset Fault OPM nn OPM nn Failed poll when unset Fault SMn SMn Failed poll when unset Fault ACM nn ACM nn Failed poll when unset Fire Circuit nnn Cctnnn A fire type circuit alarm Fire Door Open Circuit nnn Cctnnn Fire door open when unset First code User nn Keypad JUsnn KPm User entered code on Dual code keypad GSM Route Fail NONE NONE A call using the Dual comm GSM route has failed GSM Route OK NONE NONE A call using the Dual comm GSM route was successful GSR Poll Fail GSRx IGSRx GSR number x poll fail GSR Poll Rest GSHRx GSRx GSR number x polling restarted GSR Rejected NONE NONE A call from an unauthorised GSR was rejected by the panel the serial number was not programmed Head Count Number Number of activations of all circuits programmed with the head count option while the panel was unset Incorrect PIN Keypad n KPn Maximum PIN attempts reached Isol Limit Area n An The isolate limit for the system has been reached Isolate User nn Circuit mmm Usnn Cctmmm Circuit isolated by user Isolate User nn Concm Usnn m Concentrator isolated by user 36 Alarm amp Event Log messages PX QX RX Version 4 30 User Manual Issue Log Text Additional Data Display Text Event Description Isolate User nn Keypad m KPm Keypad isolated by user Isolate User nn RMm Usnn RMm Radio module isolated by user Jamming Radio module numb
20. Log Date f On a Mini keypad use theW A 15 Log Alarm buttons to change displayed 20 Time Press to choose a menu option toggle 24 Holiday t an on off option or display a list of options 25 Schedule 4 26 Group Text 28 Late Work 30 Bypass 32 Chime 52 ldentify User 71 Copy User 89 Status fon a standard keypad enterthe 2 digit code to select an option Use buttons to the displayed options i Press io move quickly through the menu The menu options shown are for a manager user on a system without access control The actual menu options available to a user will depend on the user authority the system configuration and the current system status Refer to appendix A for details Only 2 options are visible on the display but any available option can be selected by entering the 2 digit code without viewing the actual option number Each menu option is discussed in detail in this manual If no option is selected the user will be automatically logged off after 2 minutes If a chosen option is not available a reason will be displayed Refer to appendix D for details Information about the system may be displayed when logging on Refer to appendix E for details Easy Set 1 or 2 If your system is programmed with the easy set option then all PIN codes are 4 digits long and PIN codes can be entered without confirming with the w button A card or fob may sti
21. NDIX B EDITING TEXT e eeeeeeeee 0 esee 50 s svv os oroso seos senses en enas 34 APPENDIX C LOG 55 8 4 0 eset tn tn senses stas estos eines 35 APPENDIX C ACCESS LOG MESSAGES eeeeeeee eese entes een tasas eats einen 38 APPENDIX E MENU RESTRICTIONS 4 eere eee eene teet enean stas tata 39 PX QX RX Version 4 30 User Manual Issue APPENDIX E LOG ON MESSAGES ccsscssssssssscsssecssssscssessnsssssessssescssesssssesssssssssessesssssscssessessssssesseseoss 40 APPENDIX AUDIO 8 2 2 1 2 1 1 sensn eno 41 APPENDIX SYSTEM 0 4 4 0044 sensns tasas tas sonata sees sens tosta essen 42 5 sci R PE fru Mor E cc M Me csse e 42 SET GROUPS IRGEND egerunt Ge de RI de 42 CIRGUIDS 43 USERS D ERR EE e dane tardies peed MET es d E 44 LEGAL DISCLAIMER C RR 45 PX QX RX Version 4 30 User Manual Issue Introduction The PX Electronic Intruder Alarm System is designed to provide secure protection for the installation The system comprises a main control
22. OM A KEYPAD 10 SETTING WITHA MINK ERA 7S D AEAEE TEE ESEA AEE EEA 10 KEYSWITCH RADIO KEYFOB SETTING rrera eE A Ea A EE Ta R 11 AUEOMANGCSEITNNG 11 Aborting The Setting Proce dures da e e ean eee Tee RN MERKUR 77 OA M INLEDA KD E NAN IN E ERR EE 11 EASY EL EGG UOS ene RENI SETTING RESTRICTIONS SETTING eR CHER RR E TR REA ERE T NR TRES DUAL SET PX250HS ONLY 13 lod meer E S E E EE E E 14 LONA A MENTES TEAN E LO DN AEAEE E ATT E 14 Unsetting from a keypad rissie e re re ar e ne e Rene tab seb dtpunie EEEN Kie pee NEES tienes 14 Unsetting with Keyswitch or Radio 14 0 UNSELTING WARNINGS usu UNSETTING RESTRICTIONS UNSEEDELAY PX250 HS NE 16 DUALUNSET PX250HS ONLY eire tnter ipee ai eira E eei N 16 PX QX RX Version 4 30 User Manual Issue ACM AUTHORITY PX ONLY 22 2 22 E E ES EE BN A EEO Iuiediqedes 22 LOCKOUE PX ONLY tutes 23 EXPIRY DATE PX ONLY 23 TEL NUMBER 23 LOGS 24
23. TERRUPTED OR ERROR FREE OR THAT DEFECTS IN THE SYSTEM WILL BE CORRECTED FURTHERMORE GUARDALL DOES NOT WARRANT OR MAKE ANY REPRESENTATIONS REGARDING THE USE OR THE RESULTS OF THE USE OF THE SYSTEM OR ITS DOCUMENTATION IN TERMS OF THEIR CORRECTNESS ACCURACY RELIABILITY OR OTHERWISE NO ORAL OR WRITTEN INFORMATION OR ADVICE GIVEN BY GUARDALL OR A GUARDALL AUTHORIZED REPRESENTATIVE SHALL CREATE A WARRANTY OR IN ANY WAY INCREASE THE SCOPE OF THIS WARRANTY SOME JURISDICTIONS DO NOT ALLOW THE EXCLUSION OF IMPLIED WARRANTIES SO THE ABOVE EXCLUSION MAY NOT APPLY UNDER NO CIRCUMSTANCES INCLUDING NEGLIGENCE SHALL GUARDALL ITS LICENSORS OR THEIR DIRECTORS OFFICERS EMPLOYEES OR AGENTS BE LIABLE FOR ANY INCIDENTAL SPECIAL OR CONSEQUENTIAL DAMAGES INCLUDING DAMAGES FOR LOSS OF BUSINESS LOSS OF PROFITS BUSINESS INTERRUPTION LOSS OF BUSINESS INFORMATION AND THE LIKE ARISING OUT OF THE USE OR INABILITY TO USE THE SYSTEM OR ITS DOCUMENTATION EVEN IF GUARDALL OR A GUARDALL AUTHORIZED REPRESENTATIVE HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES SOME JURISDICTIONS DO NOT ALLOW THE LIMITATION OR EXCLUSION OF LIABILITY FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT APPLY In no event shall Guardall s total liability to you for all damages losses and causes of action whether in contract tort including negligence or otherwise exceed the amount paid for the system and its documentation 45 PX QX RX V
24. a user then the user code will be ignored until the lockout is turned off User Menu Expiry Date PX Only Code 8 Expiry dates can be programmed for all users panel and access users To delete an expiry date enter the day and month of 0000 and the current year The user authority and codes will be removed from the system at midnight on the expiry date Tel Number Code 08 An authorised user can change any telephone number that has been programmed to use the speech format home beep or SMS formats The available formats will depend on the system hardware options A telephone number of up to 16 digits can be programmed This number can include pause digits Pause digits can be entered using the button This will be displayed as a character Each pause digit represents a 1 second delay Pauses may be required if you are signalling via a PABX or if the call is routed through an old exchange Enter a single zero to turn off a telephone number Press X to delete a single digit 08 Tel Number the number is not used for speech messages Not Available No Authority enter the telephone number e An alarm in the home beep format is transmitted as a series of DTMF tones For example if channel 3 was active the transmitted message would be 333 lt 25 gt 3 3 3 2s delay 3 3 3 2s delay 333 2s delay 3 Where 3 is the tone pair for DTMF digit 3 The channel information is r
25. asons why a menu option is not available Not Available Message At Bypass Limit Call Engineer High Level Set Where Used User attempts to bypass a circuit when the number of bypassed circuits is at the programmed bypass limit User attempts to set when an engineer reset is required User attempts to unset a lower level group without unset higher levels Isolate Limit User attempts to isolate a circuit when the maximum allowed number of circuits are already isolated Isolated User attempts to bypass a circuit that is isolated Key Not Used Keypad Busy Low Level Unset No Authority No Set Area No Unset Area Not Applicable Not Programmed Option in Use Printer Busy Set Area Shunt Limit System Not Unset Test in Progress Test System Timer Control On Unset Area The key button which has been pressed is never used in the current menu User attempts to turn off a keypad that is being used User attempts to set a higher level group without setting lower levels User tries to select an option that is not allowed with their programmed authority level User selects unset when all areas that can be unset from the keypad are already unset User selects set when all areas that can be set from the keypad are already set User attempts for example to reset when there are no alarms logged The option selected is not programmed User selects an option such as test which is in being used by another user User attem
26. by the engineer if the user clock edit option is programmed Time changes are recorded in the event log Change greater than 75 minutes 24 PX QX RX Version 4 30 User Manual Issue Holiday Code 24 The programmed holidays are used in conjunction with the programmable schedules The holiday date format is day and month only No year is entered therefore the entered date will remain programmed as a holiday for all years or until it is removed from the holiday schedule It is not possible to program a holiday period that starts in December and ends in January To achieve this 2 holiday periods must be programmed Holiday 1 Enter DDMM To disable a holiday enter a date of 00 00 The start and end dates must be in chronological order A holiday can be programmed for a schedule number If the schedule number is 0 then the holiday period applies to all schedules If a specific schedule number is programmed then the holiday only applies to that schedule Schedule Code 25 A schedule consists of 4 times for each day of the week and 4 times for days which are holidays A Schedule can be used to Auto set and unset parts of the system Control outputs Enable disable keypads Enable disable user access Lock unlock access doors OB Schedule 1 Mon Schedule 1 Mon Start 1 00 00 Enter HH MM Stop 1 00 00 Group Text Code 26 A descriptor of up to 10 characters may be entered for each set
27. d for dual user set Setting Faults If the group cannot set message will be displayed This can occur at the start of setting or at the end of the exit time depending on how your system is set up and when the fault occurs If a fault occurs during the exit time the exit tone will change to a warning tone The external sounder may also have been programmed by the installation engineer to activate in the event of a failure to set 1 Workshop 2 Office 1 After the setting fault s is displayed the force set option may be presented if programmed by the i installation engineer The force set option will attempt to automatically bypass all faults The circuit s with i the fault must be programmed by the engineer to allow PIR in Hall i bypass E Workshop Seconds Left 005 PX QX RX Version 4 30 User Manual Issue Dual Set PX250HS Only 12 00 Mon 27 Sep Guardall 12 00 Mon 27 Sep Enter In the example the vault area is programmed for dual user set The first user code is 0202 and the second user code is 1234 Both users must have the authority 10 set the vault area Both user actions are logged Logon time limit reached 13 PX QX RX Version 4 30 User Manual Issue Unset Code 01 The system will have been partitioned by the installation engineer into a number of set groups The user authority will determine the choice of
28. des Each user of the system is identified by a unique code This code can be a PIN code a magnetic swipe card proximity card or fob A card or fob can only be used on a keypad variant with a proximity interface internal or external The default PIN code for user 2 is 0202 Throughout this manual user codes are only referred to as codes Operator Controls and Displays System Keypads 2 x 16 character LCD backlit display Em Mains indicator eoo eoo Proximity reader o O v target area optional The operator keypad unit incorporates a backlit liquid crystal display LCD comprising 2 lines of 16 characters and a backlit keypad to gain access to the system and to perform all authorised user functions The backlighting will be turned on during the entry time during code entry and while a user is logged on It may also be turned on using any button except and and turned off using the or X buttons Keypads may be fitted with an internal proximity reader The keypad incorporates a mains power indicator This indicator will flash if the system is operating on standby battery power Mini Keypad 2 x 16 character LCD backlit Part Set 1 set 2 buttons Alarm LED x Set LED 230v LED Proximity reader target area PX QX RX Version 4 30 User Manual Issue Cards Fobs A user PIN code can be replaced by a card or fob if the keypad i
29. des If Easy Set is not programmed and an incorrect user code is entered the incorrect code message will be displayed for a few seconds or until another key is pressed The installation engineer will have programmed a limit on the number of incorrect code attempts that can be made If more than the programmed number of code attempts are made to enter a valid user code the keypad will be locked out and the display will show Out of Service for a period of 5 minutes Any attempt to enter a user code during the locked out period will extend the period by another 5 minutes 12 00 Mon 27 Sep Guardall 5 Min Delay 12 00 Mon 27 Sep Enter Maximum Code attempts 12 00 Mon 27 Sep Incorrect Code PX QX RX Version 4 30 User Manual Issue Set Code 02 The system can be partitioned into a number of parts called set groups each of which can be individually set The programmed user authority level must allow setting and the programmed user area access will determine which set groups are available to a user Setting can be started by A user request on a keypad A user activating a keyswitch or radio Keyfob Automatically by a timer schedule Remotely from a PC using the Guardall GSR software A user request on an ACM Proximity Reader Setting modes include 1 Instant where setting is completed immediately 2 Timed where setting is completed at the end of the programmed exit time
30. e if your system is H 01313333802 configured for managed reset you will be given a code Code 123456 to reset your system This code can only be used 2 once i If an engineer or managed reset is required it will not be possible to set the system If the system is programmed for managed reset an engineer reset is required contact the alarm installation company You will be issued with a special 6 digit PIN code This PIN code can be used only once to reset the system Logon to the keypad with this PIN code to clear the engineer reset condition 12 00 Mon 27 Sep Guardall reset code 12 00 Mon 27 Sep Enter 247 PX QX RX Version 4 30 User Manual Issue Test Code 04 Each area of the system can be tested individually or all areas can be tested at the same time The test time is limited to 1 hour If the user does not end the test by the end of the test time then the panel will exit test mode automatically Enter the area number or 0 to test the system EN WENN x Not Tested Not Medus All Tested T Untested circuits will be displayed All circuits tested Qo Tel Number 1 Tel Number 2 Please Wait Please Wait All dumbeis Acknowledge Tested received The panel records all activations from sensors during the unset period When walk test is selected the panel will display all
31. e working actions are logged Late Work Enter HH MM Late Work 19 00 If Late Limit is enabled PX250HS onl f Use the arrow buttons A to increment or Late Work 18 00 decrement the late work time The late work time limits are from the normal set time to the programmed latest set time 26 PX QX RX Version 4 30 User Manual Issue The bypass option will only be available if a circuit s has been programmed as bypassable by the installation engineer The bypass circuit option allows the user to bypass a circuit that is in a fault condition When bypassed the alarm condition of a circuit is ignored When a circuit is bypassed it is ignored until the bypass is automatically removed when the circuit is next unset or until a user removes the bypass All bypass actions are stored in the event log A bypass limit will have been programmed by the installation engineer to limit the number of circuits that can be bypassed at any one time The system will display an error message if you try to exceed this limit circuit Number Limit 1 to max Enter circuit o number Circuit was Max Number of Ci hi 24hi d not bypassed be bypassed bypassed bypassed already bypassed a 01 Not Available 01 l Cct 01 Cct 01 Bypassed No Authority Normal Active Set Chime Code 32 Certain circuit types can be selected as chime circuits when unset To select
32. ed 1 5 Shunted circuit s 6 Battery test faults when setting is allowed with this type of fault 17 230 mains faults when setting allowed with this type of fault Workshop Seconds Left 005 Easy Set If easy set mode 1 is programmed then the system will start to part set when you log on During the part set exit time if the exit door circuit is opened and closed the system will full set Pressing the key during the setting time will cancel setting If easy set mode 2 is programmed then the system can be set without logging on to a keypad Up to 8 parts can be set in this way depends on the control panel type For example to set part 1 of your system from 1 The system can be set by entering 0 If using a mini keypad then the house symbol buttons can be used to set me v set first group or area XE V set second group or area ars M set first and second group or area 11 PX QX RX Version 4 30 User Manual Issue Setting Restrictions 1 selected group is programmed with a set level and a lower level set group s has not been set 2 If a user attempts to set a high level set group when a lower level is not set then a warning message will be displayed In a PX250HS there are several additional conditions that apply when setting 1 keypad may be programmed to disable setting 2 selected group may be programme
33. ed Cannot set User nn Area m Usnn Am User was not able to set an area Cct Tested Circuit nnn Cctnnn Circuit responded in walk test Changed Code User nn Keypad m KPm User changes own code Changed Code User nn User mm Usnn Usmm Manager GSR user changes code for another user Changed Time User nn Keypad m Usnn KPm Time modified old time and new time are logged Check Fuse N Panel fuse number Check Fuse Conc n Conc n Concentrator fuse Check Fuse OPM n OPM n Output module fuse Check Fuse ACM n ACM n ACM fuse Clear Circuit nnn shunt type circuit clears Clear Circuit nnn Cctnnn A Circuit alarm has cleared Code Clash User nn User mm Usnn Usmm User has chosen a new code which is the same as another user Comm Acknowledge n N Central station acknowledge alarm report Comm Fail NONE NONE Control panel comm fail input active Comm Fail n N Central station fails to acknowledges alarm report Comm Fail Module name Module name Module has reported communications fail Comm Test User nn Keypad JUsnn KPm User or the panel tested the communicator s Commission Fail User nn Usnn Encryption commission fail Commissioned User nn Usnn Encryption commission OK Data Route Fail NONE NONE call using the Dual comm data route has failed Data Route OK NONE NONE call using the Dual comm data route was successful 35 Log Text Date Changed Det Test Fail Det Test OK
34. end of the soak period any circuit which has alarmed is logged as failed Soak Off Circuit nnn Cctnnn A circuit has been taken off soak Soak On Circuit nnn Cctnnn A circuit has been put on soak Software Error N N software error has been logged Tamper Tamper Circuit nnn circuit tamper Tamper Keypad n KPn A keypad tamper Tamper SM n SMn A serial module tamper Tamper OPM n OPMn An output module tamper Tamper ACM n ACMn An ACM tamper Tamper Radio module number RM nn Radio Module tamper Tamper XiB Detector mmm Detmmm An XIB Detector is either not Mapped circuit nnn Cctnnn responding or has been removed from the system Temp Bypass Circuit nnn circuit has been temporarily until clear bypassed TX Off N N channel off TX On N N TX channel on Unset User nn Area Usnn Am A user has unset the area Unset User nn Group m Usnn m Group has been unset by a user Unset Red Circuit nnn Cctnnn Key type circuit clears Unset Req User nn Keypad KPm A user requested unset on a keypad dual unset or unset delay programmed Upload Fail GSRx GSRx Upload to GSR x failed Upload OK GSRx GSRx Upload to GSR x OK User Date Expiry Usnn Usnn User details has been removed from the system at the programmed expiry date Verify Alm Area n An A verified alarm has occurred Watchdog NONE NONE Software watchdog active Appendix C Access Log Messages Acc
35. epeated a maximum of 5 times during a call 23 PX QX RX Version 4 30 User Manual Issue The panel logs all events that occur in the system All events stored in the event log are numbered in the range 0 65535 the event index The event index will be reset to 0 when more than 65535 events have been recorded There are 2 logs the security log and if an ACM s is fitted an access log Each log can be viewed in full or filtered form on a keypad and printed if a printer is connected to the system Options 16 18 will only be displayed if there is at least one ACM on the system Only events for authorised areas and access doors will be displayed or printed 10 Log Full 1 Display PIR in Hall 11 Log Cct 2 Bypassed Circuit Number 13 Log KP 14 Log Date 12 00 00 Cct1 15 Log Alarm Bypassed 16 A Log Full 17 A Log User K 18 A Log Door dan Enter DDMMYYYY o Use the button to change the o Q Door i display view of an event and the AV i buttons to change the event being displayed When event is printed all event data is printed 00001 Mon 07 Apr 2003 00 00 02 User 2 Mr iid Logged On on KP 0 Event index Event date Event time Event details t Refer to the appendix C for details of all log messages Some users have the authority to change the time by up to 75 minutes from the time set
36. er RM nn Receiver jammed Key Fail User nn Usnn Encryption key fail Knock Circuit nnn Cctnnn Circuit first knock Late Working Usnn Area m Usnn Am Late working has been selected for the area Line Fault Module name Module name Module has reported a line fault Lockout Keypad n KPn Incorrect code attempt limit reached on the keypad Logged Off User nn Keypad m Usnn KPm User logged off keypad Logged On User nn Keypad m Usnn KPm User logged on keypad Managed Rst Keypad m KPm Managed reset code entered Marginal Circuit nnn Cctnnn Circuit is marginal Mult Alarm Circuit nnn Cctnnn Circuit has alarmed up to the multiple alarm limit Normal User nn Usnn m Isolate removed from a Normal User nn Circuit mmm Usnn Cctmmm Bypass or isolate removed from a circuit Not Unset Area n An A set group was not unset by the schedule close time Panel Tamper NONE NONE Panel case or off the wall tamper PC Access GSRx Operator YY GSRx Operator GSR operator number YY has YY logged on from GSR number x PC Disconnect GSRx Operator YY GSRx Operator GSR operator number YY has YY logged on from GSR number x Personal Attack Circuit nnn Cctnnn PA type circuit alarm Poll Fail Transmitter number nn RM mm Transmitter polling failure Poll Fault Radio module number RM nn Receiver polling fault Power Fail NONE see note NONE Supply voltage has fallen to the power fail threshold PSTN Route Fail NON
37. ersion 4 30 User Manual Issue 46 Guardall Limited Lochend Industrial Estate Newbridge Edinburgh EH28 8PL Tel 0131 333 2900 FAX 0131 333 4919 Technical Hotline 0131 333 3802 Part Number 320995 0C
38. ess Control log only messages Log Text Access Card Exit Denied Door Open Exit Forced Lock Pending RTE Set Req Unlock ie Req Additional Data User nn ACM m User nn ACM m User nn ACM m ACM User nn ACM m ACM ACM ACM ACM User nn ACM m ACM Display Text Usnn ACMm Usnn ACMm Usnn ACMm Usnn Usnn User Usnn 38 Event Description User accessed ACM m User exit by ACM m which has no door contact User denied access door held open User exit by ACM m door forced open door lock Schedule unlock pending ACM Door RTE button active User request to set from ACM m ACM door unlocked User request to unset from ACM m PX QX RX Version 4 30 User Manual Issue Appendix E Menu Restrictions If a menu number is entered and the option is not available then a reason will be displayed For example if no area is set and you select unset the panel will prompt with the reason the unset option is not available Not Available No Set Area This indicates that there is no set area available to the user There are many reasons why an option is not available If you think an option should be available but the prompt is not on display then enter the menu number and the panel will display an appropriate message The following table shows the re
39. groups which can be unset There are several methods of unsetting available to the user which are discussed in the following section Unsetting can be started by A user request on a keypad A user activating a keyswitch or radio Keyfob Automatically by a timer schedule Remotely from a PC using the Guardall GSR software A user request on an ACM Proximity Reader Your installation engineer should advise which of the above options have been programmed on your system Unsetting Methods If set group incorporates an entry route in the unsetting procedure then opening a final entry door to the area will start a pre programmed entry timer The user must proceed directly to the keypad or keyswitch via a pre determined entry route and unset the group as described If the group is not unset before the entry time has expired a warning period of 30 seconds will be given This is to warn the user that an alarm condition will occur if the group is not unset by the end of the warning period If the group is not unset by the time that the total entry time and warning time has expired an alarm condition will be initiated To comply with the requirements of DD243 2002 during the entry time all alarms in the unsetting area s are ignored Unsetting from a keypad Your installer may have set up your system to allow automatic unset when your user code is entered The diagram shows all 3 possible unset scenarios when a user logs on to a
40. he default user codes are shown in the table The maximum PIN code length is 6 digits Default Codes User Number 2 3 last user New PIN Not Available PX250HS Only The system checks the newly entered PIN code for security purposes If the PIN code is either sequential e g 123456 or all the same numbers e g 5555 then this PIN code is not allowed A message is displayed Insecure PIN and the user is prompted to enter a more secure PIN code 20 PX QX RX Version 4 30 User Manual Issue User Menu Card Code 3 The procedure for adding a card is similar to adding a new PIN Present the new card to reader when prompted to do so Alternatively if the card number is known it can be entered on the keypad The maximum number of card digits excluding the optional site ID is 8 digits User Menu Authority Code 4 Users can be programmed with a number of options including authority level group access and timed access The available menu options are dependent on the programmed user authority Refer to the menus options section for details of the menu options available to each authority level Option Range Description Code Change On Off Some user types are allowed by default to change their own code refer to authority table This feature can be disabled for any user without manager authority LogOnSet On Off If this option is on the system will show a list of set groups that are available to set If only
41. ll be used in place of a PIN when easy set is programmed Help When the main user menu is on display press the help button to display information about the system There are 3 options 1 Itis recommended that the manager code is changed from the default as soon as possible PX QX RX Version 4 30 User Manual Issue Option Description Assist Select to connect to a remote service operator Your alarm company may not support this feature Contract The customer contract number is a 6 digit number programmed by the installation engineer that uniquely identifies your system Product Info The product info option displays the control panel order code and firmware version number and if fitted the Dialler version number An authorised user can change some of the system parameters When changing an item the help button can be used to display the allowed values Remote Assist Before using the remote assist option you must obtain a number from your alarm company When you need to use the remote service you will be prompted to enter this number and the panel will dial the alarm company The alarm company will then be able to check the condition of your system and identify and resolve problems Assist 1 Vv Dial f You will now be logged off and the system will now connect to the remote service centre 1 1 N Service not available on entered number 12 00 Mon 27 Sep Guardall Incorrect Co
42. minutes after the time the group was set 6 The schedule unset option does not apply 15 PX QX RX Version 4 30 User Manual Issue 12 00 Mon 27 Sep Guardall 12 00 Mon 27 Sep Enter il programm unset delay The unset delay time is programmed by n the example the vault area is programmed with an he installation engineer Log off after unset ed 12 00 Mon 27 Sep Guardall 12 00 Mon 27 Sep Enter Logon time In the example the vault area is programmed for dual user unset The first user code is 0202 and the second user code is 1234 Both users must have the authority ito unset the vault area Both user actions are logged in the event log imit reached 46x PX QX RX Version 4 30 User Manual Issue The resetting method programmed by the alarm company engineer for each area and the system will depend on the particular security requirements of the area or system There are 3 types of reset 1 Customer reset where the customer can reset any alarm 2 Engineer reset where the alarm company engineer must reset all alarms 3 Managed reset where the customer can reset an alarm after reporting the event to the alarm company Alarm PIR in Office Alarm cannot be reset o f If your system is programmed for engineer reset a telephone number and code will be displayed Call this number and quote your cod
43. mnopqrstuvwxyz i User Number 03 4 8 lt gt 0123456789 A Smith 34 PX QX RX Version 4 30 User Manual Issue Appendix C Log Messages Alarm amp Event Log messages Log Text Additional Data Display Text Event Description 230v Fault NONE see note NONE Mains supply failed 230 see note NONE Mains supply restored ACS Log On Keypad KPn Log On cct type active A Set Fault Usnn Area Usnn Am An area auto set with faults Active Circuit Circuit nnn Cctnnn User selected active circuit test Alarm Circuit nnn Cctnnn A Circuit alarm Alarm master shunt Circuit nnn Cctnnn Master shunt type circuit alarms Alarm Abort User nn Keypad m Usnn KPm Alarm abort signal transmitted Anti mask Circuit nnn Cctnnn A Circuit program with the anti mask option has alarmed Auth Fail User nn Usnn Encryption authentication fail Auto Check Fail Circuit nnn Cctnnn A Circuit has failed to activate during the auto check period Auto Check OK NONE NONE Circuit Auto Check was OK Bat Restore NONE see note NONE The battery voltage is normal after a battery low Bat Monitor Fail NONE see note NONE Battery voltage is low or not present during a battery test Battery Low NONE see note NONE The battery has reached the low volts threshold after a mains fail Battery Low Transmitter number Transmitter battery low Bypass User nn Circuit mmm Usnn Cctmmm Circuit bypass
44. of ACM doors Challenged On Off If a user is programmed as challenged then the ACM door ACM Authority release and open times will be automatically doubled for the user H 0 2 n 1 Visitor Level Normal 2 Escort ACM 1 Off 3 Supervisor ACM 2 Off ACM 32 Challenged Off Level Access level Help Menu User access right will depend on the programmed user level and the programmed access door mode programmed by the installation engineer There are no restrictions on exit User Access Restrictions User Mode Door Mode Dual Escort Supervisor Normal 1 v X Visitor x 2 x Escort 1 4 x Supervisor 3 3 3 Notes 1 Dual mode access requires 2 users with either Normal Escort or Supervisor authority 2 Avisitor user may only gain access within 10 seconds an escort user presenting their token 3 supervisor user can access a door with lockout enabled 4 An escort user can gain access by presenting their token twice within 10 seconds User Menu Schedule Code 6 A user can be programmed with a schedule to control access times Program 00 to allow 24hr access The schedules can be programmed using option 25 22 PX QX RX Version 4 30 User Manual Issue User Menu Lockout PX Only Code 7 This option will only be available if at least one ACM is fitted to the system If the lockout option is on for
45. p by Isolated i the installation engineer solate 3 Isolated circuit s 4 Line Fault only when setting with telephone line fault is allowed 5 Shunted circuit s 6 Circuit has reached the programmed multiple alarm limit 7 Battery test faults 8 230v mains faults Unsetting Restrictions The selected group is programmed with set level higher level set group s has not been unset If a user attempts to unset a high level set group when a lower level is set then a warning message will be displayed In a PX250HS there are several additional conditions that apply when unsetting 1 The keypad must be programmed by the engineer to allow unset 2 The selected group may be programmed for dual user unset 3 An open close schedule may be programmed for the selected group and the time is after the programmed close time This condition may be ignored following an alarm in one of the set group areas if the set group is programmed with an alarm unset time In this case after unsetting the set group will automatically set after the programmed Alarm Unset period 4 The selected group may be programmed with an Unset Delay time and set group will only unset at the end of the programmed unset delay period A message will be displayed during this time and the user unset request will be logged 5 Ifa group is manually set before the scheduled set time then it may be unset up to the number of programmed Early Set
46. pts to print and the printer is in use User attempts to access test when an area is set User attempts to shunt a circuit when the maximum allowed number of circuits are already shunted User attempts to access an option that is only available when the system is unset for example the event log User attempts to set an area that is being tested on another keypad Circuit check fail has occurred and the user has selected set User attempts to log on outwith the schedule times User attempts to unset an unset area 39 PX QX RX Version 4 30 User Manual Issue Appendix E Log On Messages When a user logs on the system may display a special message s before the normal menu is displayed The special messages are shown in the table Message Reason Alarm Abort User logs on within the alarm abort period programmable option Call Engineer You should call the installation company The details will then be displayed Cannot Set The system cannot set the reason s will then be displayed Code Known Another user has chosen your code You will then be given the option of immediately changing your code This message will always be displayed on log on until the code is changed Det Test Fail A detector in area x has failed an automatic detector test Note that this warning will not be shown if the log on set option applies A group s is set and is programmed to automatically unset when a user logs on A circui
47. s fitted with the optional internal or external reader All Guardall proximity cards and fobs are manufactured with a unique code and duplicate cards or fobs cannot be obtained Spare or replacement cards or fobs can be obtained from the installation company Dual User Code Operation Where a higher level of security is required a keypad may have been programmed to require two user codes to be entered before logging a user on to the system Both user codes must be authorised and are logged by the system The authority of the second user code entered is used by the system The second user code must be entered within 15 seconds of the first user code User Card PIN Operation Each user can be programmed with both a PIN and a card If the user Card PIN option is programmed then both codes have to be entered before the user can log on to a keypad PX QX RX Version 4 30 User Manual Issue Using the System The LCD keypad will normally display the time date and company name If a valid code is entered the user menu will normally be displayed The default manager code is 0202 Enter this code followed by the V button to log on 12 00 Mon 27 Sep Guardall user token on mini keypad or e at power up Unset lt Select 05 Engineer Set 06 PIN Reset Alarms 07 User User 08 Tel Number Log Full 10 Log Full Late Work 11 Log Cct Bypass 12 Log User Time 13 Log KP 14
48. stem through a PX keypad with an integrated proximity reader Add A User Code 50 This option will only be available if at least one ACM is fitted to the system 50 Add A User Present Card Fob The first free user number is displayed D r 1 1 1 The user number is automatically incremented when a Vite valid card fob is presented rea User 4 Present Card Fob The user authority is automatically set to Access for all ACM doors and the user text descriptor will be defaulted If required the user authority can be changed using the edit user option 30 PX QX RX Version 4 30 User Manual Issue Delete User Code 51 This option will only be available if at least one ACM is fitted to the system In the example shown user 3 is deleted from the system Delete Users f Enter the range of users to delete To delete a single user enter the user number twice User numbers entered without leading zeros oo Delete Users T oo Delete Users 3 Door Unlock Code 53 This option will only be available if at least one ACM is fitted to the system An ACM door can be manually locked unlocked from a keypad An optional unlock time of up to 255 minutes can be programmed If a time of zero is programmed the door will remain unlocked until the unlock option is turned off While a door is locked it can still be opened by presenting a valid user card
49. the PIN option Then follow the display prompts All user PIN code changes are recorded in the system event log If the PIN code option is not available this means that the system has been programmed to prevent you from changing your user PIN code and a new PIN code must be allocated by the security system manager In the example shown the user changes code to 1234 PIN OK PIN not unique New PIN Not Available If another user on the system already uses the chosen PIN code then that user will be alerted when next logging on to the system The user whose PIN is known must change PIN code to avoid seeing the warning message on every log on 19 PX QX RX Version 4 30 User Manual Issue User Code 07 Any master user can change the name user code and authority for any user except the engineer To modify a user s details enter the user number in the range 2 max users In the programming example user 3 is used The user 2 configuration may only be changed by user 1 or user 2 Access system users can be added quickly using the Add User menu option 50 rather than programming them individually User Menu Nome Code 1 When the name option is selected the current user descriptor will be displayed and can be edited Refer to appendix B for details User names can be up to 10 characters long User Menu PIN 2 For details of changing code refer to the main menu code change option T
50. the chime function for a circuit enter the circuit number In the example chime is turned on for circuit 1 Press any button 27 PX QX RX Version 4 30 User Manual Issue A manager or ordinary user can be programmed with the shunt option The shunt option will only be displayed if there are shuntable circuits in the user authorised areas Shunted circuits may be viewed at any time using option 89 Cct Status All shunt actions are logged Enter circuit number Max Number of Circuit cannot Circuit was circuits already be shunted shunted hunted Not Available Cct 01 Not Available Not Programmed Shunt Off Shunt Limit Print Text Code 40 This option will only be available if a printer is connected to the system The print text option will print all text descriptors Print Hols Code 42 This option will only be available if a printer is connected to the system The print holiday option will print all holiday periods Identify User Code 52 This option allows a user to be identified by presenting the card fob Circuit was not shunted User 3 fob presented Unused card fob presented Code Not Used User 20 fob presented 28 PX QX RX Version 4 30 User Manual Issue Copy User Code 71 71 Copy User Enter the user to copy here Copy User 4 Enterthe first and last user the copy range here 4 1 To copy a single user
51. ts has alarmed the maximum number of times allowed programmable The circuit details will then be displayed A managed reset code has been accepted User logs on during the setting exit period Soak Cct Fails Circuits which have been put on special test by the installation engineer have alarmed Unset Alarm An unset alarm has occurred the details will then be displayed 40 PX QX RX Version 4 30 User Manual Issue Appendix F Audio Commands This section only applies to systems that are fitted with an audio bus or a speech module The speech and audio functions of the system by using a DTMF telephone handset To use an audio or speech function 1 Dial the control panel telephone number 2 Logon using your PIN code and terminate with the button 3 Enter the required function code Code Meaning 01 32 Activate TalkBack modules 1 to 32 00 Activate all TalkBack modules Toggle between listen and talk modes Replay stored audio the system must fitted with audio interface with the speech record option 40 41 49 Record channel messages 1 to 8 410 Record set message 411 Record unset message 50 Play main message 51 59 Play channel message 1 to 8 510 Play set message 511 Play unset message 61 68 output 1 8 the selected output must

Download Pdf Manuals

image

Related Search

Related Contents

Pioneer DV-300-K User's Manual  composer 9 user manual  CY-8100 Human LOXL2 ELISA Kit  LaCie blue eye  TS104 User manual SIRIUS 21 LED 3W RGB 3in1 IP65    Small Vibrating Equipment  Manuale d'installazione & manutenzione Installation manual  Betriebsanleitung Plattformwaage  Philips Jam Jacket DLA40116  