Installation Manual Installatie Handleiding Sensore da esterno
Contents
1. 1 Technical specification Detector voltage 9V to 16V dc Current Quiescent 10 mA 12V Maximum 12 mA 12V Max Ripple 2V peak to peak at 12V dc PIR Coverage Adjustment 10 to 50 vertically 90 horizontally LED Indication Test Input high to enable Temperature Range 25 C to 60 C Temperature compensation Digitally profiled temperature compensation Alarm Output Normally Closed N C or Normally Open N O NC ALARM voltage free solid state relay Rated at 30V dc 50 mA with a maximum 10 Q series resistance Alarm Period Approximately 3 seconds Tamper Output Normally closed voltage free switch contacts Rated at 24V dc 50 mA Test Input Normally low or open circuit connect to detector s positive supply to activate High Must have common ground with detector I P rating IP 55 provided that professional guidelines as well as the installation advice contained in this manual are adhered to NOTE NOT FOR MAINS SWITCHING VEX meets the requirements of TS 50131 2 2 2004 Grade 2 Class IV 2 Initial Installation The Guardall VEx is designed to tolerate a wide range of environments however the normal professional installation guidelines should be followed a Avoid the main false alarm sources Sunlight shining directly onto the detector lens Heat sources within a zone Mount the detector on a stable surface which is not subject to vibration Large objects placed in fro
2. Diagrams Diagramma Diagrammes Abbildungen Mounting bracket Montagebeugel Staffa Snodo Rotule Wandhalter Upper mounting holes Bovenste montagegaten Fori di montaggio superiori Trous de fixation haut obere Befestigungsl cher Head Detector Testa sensore T amp te de detection Sensorkopf Lens Lens Lente Lentille Linse LED LED LED Led de visualisation LED Anzeige Vertical adjustment Verticale instelling Regolazione verticale R glage vertical Vertikale Einstellung Horizontal adjustment Horizontale instelling Regolazione orizzontale R glage horizontal Horizontale Einstellung Cover Deksel aan onderzijde Coperchio Capot Bodendeckel Cover screw Dekselschroef Vite coperchio Vis capot Deckelschraube Tamper switch Sabotageschakelaar Switch manomissione Contact autoprotection Sabotageschalter Pull out connector block Verwijderbare klemmenstrook Connettore estraibile Bornier amovible herausnehmbarer Klemmenblock Wing nut Vleuglemoer Dado ad alette Vis papillon Fl gelschraube Cover locating clip Deksel vergrendeling Clip coperchio Clip pour capot Deckelhalterung Wire harness restraints Ader vergrendeling Incastri per cablaggio Maintien de c blage Kabelhalterung Optional N O alarm output Purple Dutch Uscita allarme opzionale viola normalmente aperta N O Fil pour utiliser la sortie alarme NO fil violet Freiwillig Alarmausgang
3. improving quality and design Guardall reserve the right to amend specifications without giving prior notice Faulty product should be returned to your supplier Note Guardall recommend that the detector is regularly walk tested back to the control panel and that installers regularly advise their customers to do this Guardall Limited Lochend Industrial Estate Newbridge Edinburgh EH28 8PL Technical Hotline 0131 333 3802 Website www guardall co uk Nederlands 1 Technische gegevens 9 V tot 16 V dc Opgenomen stroom 12 mA in rust 11 mA in alarm Bedrijfsspanning Max rimpelspanning 2 Vtt bij 12 V dc Bereikinstelling 10 to 50 verticaal 90 horizontaal Looptest LED Temperatuur bereik 25 C to 60 C Extern te activeren Temperatuur compensatie Automatische temperatuur compensatie Alarm uitgang Normaal gesloten spanningsvrij relais contact Max 30 V 50mA voorzien van een 10 Q serieweerstand Alarmperiode Ongeveer 3 seconden Sabotage uitgang Normaal gesloten spanningsvrij contact NC TAMPER Max 24 V 50mA Test ingang TEST Normaal 0 Volt of niet aangesloten 12V aanbrengen om de test LED te activeren OVolt gemeenschappelijk met detector voeding IP waarde IP55 uitgaande van correcte installatie De VEX voldoet aan TS 50131 2 2 2004 Grade 2 Class IV DEZE DETECTOR IS NIET GESCHIKT VOOR ET SCHAKELEN VAN 230V NETSPANNING 2 Voorbereiding en installeren De Guardall
4. VEx is ontworpen voor problemloos gebruik in de meest uiteenlopende situaties Echter de normale professionele richtliinen dienen in acht genomen te worden a Vermijdt mogelijke vals alarmbronnen Zonlicht direct op de detector lens Warmte bronnen in het detectieveld Monteer de detector op een stevige trillingsvrije wand Grote objecten voor de detector beinvloeden het detectiebereik b Voorbereiding amp montage Bepaal de montageplaats en de kabelroute De geadviseerde hoogte is 2 3m Indien de detector op een afwijkende hoogte gemonteerd wordt moet hierop de horizontale verticale instelling aangepast worden zie sectie 3d Draai de dekselschroef los niet verwijderen en verwijder het deksel Haal de klemmenstrook uit de vergrendeling Draai de vleuglemoer geheel los Haal de detector los en laat deze hangen aan de draden De 3 montagegaten zijn nu zichtbaar Boor de montagegaten gebruik makend van de boormal afgebeeld op de doos en monteer de montagebeugel Let hierbij op een juiste orientatie zie afbeelding op de voorzijde van deze handleiding Plaats de detector terug op de beugel Let hierbij op dat de O ring correct geplaatst is Draai de vleugelmoer zodanig vast dat afstelling van de detector nog mogelijk is De klemmenstrook nog niet terugplaatsen c Aansluiten Voer de kabel in de detector via de kabelinvoer Zorg ervoor dat de klemmenstrook nog niet teruggeplaatst is Sluit d
5. Violett normallerweise ge ffnet N O Pull out connector Verwijderbare klemmenstrook Connettore Estraibile Bornier Amovible Herausnehmbarer Klemmenblock Blue Blauw Blu Bleu Blau Blue Blauw Blu Bleu Blau Green Groen Verde Vert Gr n Yellow or Purple Geel Giallo o Viola Jaune ou violet Gelb oder Violett Orange Oranje Arancione Orange Red Rood Rosso Rouge Rot Black Zwart Nero Noir Schwarz I p LI LI r r 1 III eN mal l Fa ELE olo de ir rr pr aad Oh S Me done Le DS L SL JA A A IM L TAMPER ALARM Coverage Diagrams Detectiepatroon Diagrammi di copertura Diagramme de couverture Erfassungsbereich Volumetric Side View Volumetrisch Zijaanzicht Volumetrico Vista laterale Vue de c te Volum trique Volumetrische Seitenansicht Volumetric Top View Volumetrisch Bovenaanzicht Volumetrico Vista in pianta 17 zone su 3 piani 23m Vue de dessus Volum trique Volumetrische Draufsicht 0 5m 10m 15m Long Range Top View Long Range Bovenaanzicht Perimetrale Vista in pianta 10 zone su 3 piani Vue de dessus Longue port e Langstrecke Draufsicht 10m 20m 30m Installation Manual Installatie Handleiding Sensore da esterno Manuale di Installazione Notice d installation Installationsanleitung Long Range Side View Long Range Zijaanzicht Perimetrale Vista laterale Vue de c t Longue port e Langstrecke Seitenansicht 0 10m 20m 30m
6. detectie of een succesvolle zelf test Voedingsspannings monitor De voedingsspanning van de detector wordt continu gecontroleerd Indien deze lager wordt dan 9 V zal de LED langzaam knipperen 1x per seconde Deze conditie wordt automatisch hersteld indien de voedingsspanning weer boven de 9 V komt 5 LED Indicatie Lage spanning Knippert langzaam fel zwak 1 x per sec Alarm 3 sec aan indien de LED extern geactiveerd is Zelf test fout LED brand zwak 6 Foutzoeken Geen LED Controleer of de LED geactiveerd is 12 indicatie Vdc op TEST ingang LED knippert Controleer of de voedingsspanning hoger langzaam fel zwak is dan 9 V dc Slechte detectie Controleer de afstelling van de detector LED brand zwak Periodieke zelf test fout Controleer de detector op juiste werking Voor eventuele vragen kuntu kontakt opnemen met uw distributeur 7 Varianten Artikelnr W74302 15m Volumetrisch Artiklenr W74303 30m Long Range 8 Garantie Een aanspraak op garantie beperkt zich tot fabricage en materiaalfouten Ter verbetering van kwaliteit en het ontwerp behoudt Guardall zich het recht voor om zonder voorafgaande mededeling specificaties te verbeteren Produkten die mankementen vertonen gaarne aan uw leverancier teruggeven met een beschrijving van het de mankement en Opmerking Guardall adviseerd dat de detector regelmatig 1x per maand getest wordt op juiste werking Guardall Limited Lochend Industrial Es
7. niedrige flackert langsam 1Hz 1x Sek zwischen Spannung hell und schwach erleuchtet Alarm Leuchtet 3 Sekunden lang falls LED aktiviert periodischer Selbsttestfehler LED schwach erleuchtet 6 Fehlersuche Keine LED Anzeige Pr fen Sie ob LED aktiviert ist d h Testklemme auf 12 V LED flackert langsam Pr fen Sie die Versorgungsspannung schwach hell gt 9V LED st ndig Pr fen Sie auf starkes Licht und andere erleuchtet d h PIR m gliche Falschalarmursachen st ndig in Alarm Schlechte Erfassung Pr fen Sie die Einstellung des Sensorkopfes Schwache LED periodischer Selbsttestfehler pr fen Sie Anzeige Funktion der Einheit F r weitere Fragen setzen Sie sich bitte mit Ihrem Lieferanten in Verbindung 7 Varianten W74302 15 m Volumetrisch W74303 30 m Langstrecke 8 Garantie Zur Verbesserung von Qualit t und Design beh lt sich Guardall das Recht vor ohne vorherige Mitteilung Spezifikationen zu ndern Fehlerhafte Produkte senden Sie bitte an IhrenLieferanten zur ck Der Gew hrleistungsanspruch erstreckt sich auf Fertigungs und Materialfehler ACHTUNG Guardall empfiehlt einen regelm igen G Test Funktionstest des Melders an der Zentrale beim Kunden durch den Installateur durchzuf hren Guardall Ltd Lochend Industrial Estate Newbridge Edinburgh EH28 8PL Schottland Technische Hotline englisch 0044 131 333 3802 Website www guardall co uk Part No 320878 0C Diagrams
8. pour mener le m me type de test Guardall SAS 23 Rue Casimir P rier BP 118 95874 BEZONS France Tel 33 0 1 34 34 34 90 E mail technique guardall fr Website www guardall fr 1 Technische Daten 9 16V dc Stromverbrauch Ruhe Spannung 12mA bei 12V dc Maximum 11mA Alarm normal bei 12V dc Welligkeit 2V Spitze Spitze bei 12V dc Reichweiten 10 bis 50 senkrecht 90 waagerecht anpassung LED Anzeige ber Testklemme aktivierbar Temperaturbereich 25 C bis 60 C Digitale Temperaturkompensation unter und oberhalb von K rpertemperatur Temperatur anpassung Alarmausgang Normalerweise Geschlossen N C oder ALARM Normalerweise Ge ffnet N O spannung freies Halbleiterrelais Veranschlagen an DC 30V 50mA mit einem Maximum 10 Reihenschutzwiderstand Alarmdauer ca 3 Sekunden Sabotagekontakt potentialfreier ffner max 30 V 50 mA TAMPER Testeingang Normal OV Low oder offene Verbindung TEST 12 V High zur Aktivierung Gleiche Potentiale wie Spannungsversorgung erforderlich I P Wert IP 55 vorausgesetzt da professionelle Richtlinien sowie die Anweisungen dieser Installationsanleitung befolgt werden ACHTUNG NICHT AN NETZSPANNUNG ANSCHLIESSEN Der VEX entspricht den Anforderungen von TS 50131 2 2 2004 Klasse 2 Kategorie IV 2 Installationsvorbereitung Der Guardall VEx ist f r den Einsatz in den verschiedensten Umgebungsbedingungen geeigne
9. 4 Diagnostic Test p riodique Un test interne lectrique est op r r guli rement En cas de d faillance la led s allume faiblement pendant environ 1 heure Cet tat est effac soit apr s une d tection ou au prochain test p riodique correct Supervision de l alimentation Si la tension est inf rieure 9 V la led clignote toute les secondes faible fort Cet tat disparait d s le retour d une tension supperieure 9V 5 Indication de la led Tension basse Clignote faible fort 1 fois seconde Alarme Allum e environ 3 secondes D faut test p riodique Led faiblement allum e 6 Depannage Led teinte V rifier entr e test 12V Led clignote faible forte Tension inf rieure 9V Led allum e en Pr sence de faisceaux lumineux ou autres permanence sources d interf rence D tection faible R gler la t te Led faiblement allum e D faut test p riodique 7 Versions W74302 15 m Volum trique W74303 30 m Longue port e 8 Garantie Tous les produits Guardall sont garantis contre les ventuels vices de fabrication Dans le soucis d am liorer la qualit et les performances Guardall se r serve le droit de modifier ses produits sans pr avis Tous produit d fectueux doit tre retourn a votre revendeur Note Guardall recommande un test r gulier du d tecteur et de v rifier l arrivee de l information sur la centrale L installateur doit conseiller l utilisateur final
10. ant la rotule et en orientant la t te convenablement e Apres ce r glage serrer legerement la t te et proc der des tests de d clenchement dans le champ souhait s assurer que la centrale re oit bien les informations Serrer ensuite la t te et fermer le capot en s assurant qu il est bien dans le clips
11. d alette non allentarlo troppo quindi attraversare l area protetta e verificare che la segnalazione di allarme venga ricevuta dalla centrale di allarme In fine posizionare i fili dentro il sensore chiudere il coperchio assicurandosi di averlo ben posizionato nella clip predisposta prima di stringere la vite La portata e la copertura mostrata si intendono con il sensore montato a 2 3m di altezza con un inclinazione tale per cui punti ad un metro di altezza a 15 mt di distanza Ci pu variare se vengono scelte diverse altezze di montaggio o inclinazioni della testa Accertarsi che il campo di visione del sensore non sia coperto Effettuare prove di copertura pi volte durante l installazione 4 Diagnostica Self Test Periodico Il sensore esegue periodicamente un self test interno Se questo test dovesse fallire il LED si illuminer debolmente circa un ora dopo Questa condizione verr resettata da un allarme del sensore o da un successivo self test periodico con esito positivo Indicazione Bassa Tensione La tensione di alimentazione viene continuamente monitorata Se dovesse diminuire significativamente al di sotto dei 9V il LED lampegger con frequenza di 1Hz una volta al secondo tra illuminato e poco illuminato Questa condizione verr resettata se la tensione di alimenatzione torner sopra i 9V dc 5 Indicazioni LED Bassa Tensione Lamp lento 1 Hz una volta sec tra illuminato e poco illuminato Allarme On
12. e Sebbene VEx stato progettato per tollerare diversi tipi di condizioni ambientali le normali regole professioni di installazione dovranno essere seguite come segue a Evitare le principali sorgenti di falso allarme Esposizione diretta verso la luce solare Sorgenti di calore all interno dell area Installare il sensore su di una superficie stabile non sogetta a vibrazioni Ogetti ingombranti posti davanti al sensore ne modificano il campo di copertura PRECAUZIONI AGGIUNTIVE Evitare di usare questo dispositivo come sensore di sicurezza primaria L unit disegnata per rilevare variazioni di energia infrarossa emessa da un corpo umano Tuttavia occorre precisare che queste variazioni possono essere generate anche da altre cause dando luogo ad un allarme indesiderato b Preparazione amp Montaggio Scegliere la posizione di fissaggio e l ingresso cavi L altezza raccomandata 2 3 mt Se richiesto dall applicazione il sensore pu essere montato ad altre altezze e regolata l inclinazione verdi sez 3d Allentare la vite non toglierla e rimuovere il coperchio Estrarre la morsettiera dalla posizione di ancoraggio Svitare il dado ad alette per allentare il blocco sensore Lasciare il sensore svincolato dallo snodo in modo da poter esporre i tre fori di fissagio Fissare la staffa al muro usando tutti e tre i fori ed accertarsi del corretto orientamento verdi piani copertura Riposizionare co
13. e draden aan op de klemmenstrook Plaats de klemmenstrook terug in de vergrendeling Het deksel voorzijde nog niet terugplaatsen 3 Controle van het detectie bereik Opmerking Er is een kleine vertraging minder dan 1 seconde tussen het moment van detectie en het genereren van een alarm waarin de Guardall VEx het gedetecteerde signaal verwerkt Controleer het detectiebereik als volgt a Controleer de voedingsspanning minimaal 9Vdc maximaal 16 V de b Activeer de LED door 12 V aan te sluiten op klem TEST groene draad c Een eerste detectie bij de Volumetrische uitvoering zal de LED kort doen oplichten indien de TEST ingang is aangesloten op 12V Een 2e detectie binnen 25 seconden zal een alarm melding genereren Bij de Long Range uitvoering zal elke detectie een alarm genereren d De horizontale en verticale instelling gebeurt door de detector in de gewenste positie te draaien e Draai de vleugelmoer hand vast en voer en looptest uit om het detectiebereik te controleren Controleer tevens of het controle paneel de meldingen registreert Plaats tot slot het deksel aan de onderzijde en draai de dekselschroef vast 4 Diagnose Periodieke zelf test De detector beschikt over een automatische zelf test van het electronische circuit Indien tijdens deze test een fout wordt geconstateerd zal na ongeveer 1 uur de LED van de detector zwak branden Deze conditie wordt automatisch hersteld na een alarm
14. ector s coverage during installation 4 Diagnostics Periodic self test The detector regularly performs an internal electrical self test If the self test detects a failure the LED will illuminate dimly within approximately an hour This condition will be reset by either a unit alarm or a successful periodic self test Supply voltage monitor The supply is continuously monitored If it falls significantly below 9V the LED will flash at 1Hz once second between bright and dimly illuminated This condition will be reset if the supply voltage returns to greater than 9V dc 5 LED Indications Low Voltage Flashing slow 1 Hz once sec between bright and dimly illuminated Alarm On for 3 seconds if LED enabled Periodic self test fail LED illuminated dimly 6 Troubleshooting No LED indication Check Test Input is high LED flashing slowly bright dim Check supply voltage is greater than 9V dc Continuous PIR Check for bright light and other known activity indicated constant alarm sources by LED activity Poor detection Check head adjustment LED illuminated Periodic self test fail check unit operation dimly Any further queries can be directed to the Guardall Technical Hotline 0131 333 3802 7 Variants W74302 15m Volumetric W74303 30m Long Range 8 Warranty All Guardall products are warranted against defects in workmanship in materials details available on request In the interests of
15. eur plus importante est possible condition de tester correctement la couverture souhait e D visser la vis sans la retirer et soulever le capot en le d logeant de l encoche Sortir le bornier pr fix pour faciliter le c blage Desserrer la t te en agissant sur la vis papillon pour la d gager de la rotule Ecarter la t te sur le c t pour acc der aux trous des vis de fixation de la rotule Fixer la rotule orienter la t te selon l application en tenant compte des rep res pour le r glage vertical et horizontal c C blage Passer le c ble par le trou de passage Retirer le bornier de son logement et c bler les fils sur les bornes libres Choisir le type de contact pour l alarme NO ou NF NF laisser en place le fil jaune mis par d faut NO remplacer le fil jaune par le fil violet libre dans la rotule Remettre le bornier dans son logement 3 Test de couverture Note chaque alarme donnera une information d alarme apr s 1 seconde d analyse a V rifier que le d tecteur est bien aliment 9 16 V b Activer la led en injectant un 12V sur la borne test c La premi re sollicitation fera clignoter la led si l entr e test est au 12V la seconde sollicitation dans les 25 secondes suivantes donnera une alarme sur le mod le volum trique Sur le mod le longue port e une seule sollicitation donnera une alarme d Le r glage vertical et horizontal s obtient en desserr
16. gelschraube wieder auf ziehen sie aber noch nicht wieder an Lassen Sie die Fl gelschraube und den Klemmenblock lose h ngen c Verkabelung F hren Sie die Kabel durch die Einf hrungsl cher Schlie en Sie die Kabel an die freie Seite des herausgel sten Kabelblocks an Setzen Sie den den Klemmenblock wieder in die Halterung ein W hlen Sie die Melderkontakte entweder Normalerweise Geschlossen N C oder Normalerweise Ge ffnet N O N C R ckstellung Der gelbe Draht in der mittleren Position des Klemmenblockes N O Ersetzen Sie den gelben Draht mit dem violetten treibend Draht in der mittleren Position des Klemmenblockes Den Bodendeckel noch nicht wieder aufsetzen 3 PIR Reichweiteneinstellung Bitte beachten Sie daB zwischen der Bewegung und der Alarmausl sung eine kurze Pause besteht weniger als 1 Sekunde in der der Guardall VEx das empfangene Signal verarbeitet Verfahren Sie mit dem Reichweitentest wie folgt a Die Versorgungsspannung mu zwischen 9 und 16V dc liegen b Aktivieren Sie die LED Testklemme auf 12 V c Die erste Meldung einer volumetrischen Einheit l st ein kurzes Aufblinken der LED aus falls aktiviert Eine zweite Meldung innerhalb von 25 Sekunden ist erforderlich um einen Alarm auszul sen Alle Meldungen einer Korridoreinheit l sen einen Alarm aus d Die vertikale und horizontale Ausrichtung wird angepa t indem Sie die Fl gelschraube lockern und den Sensork
17. n cura la testa del sensore facendo attenzione alla guarnizione Riavvitare il dado ad alette Lasciare il dado ad alette ed il connettore allentati c Collegamento Far passare il cavo attraverso il foro ingresso cavi Accertarsi che la morsettiera sia fuori dalla staffa Selzionare il contatto d allarme Normalmente Chiuso N C o Normalmente Aperto N O N C Default II filo giallo nella posione centrale del connettore N O Sostituire il filo giallo con il viola flottante nella posione centrale del connettore Inserire la morsettiera nella staffa Non chiudere ancora il coperchio 3 Controllo della copertura Si noti che intercorre un breve periodo di tempo meno di un 1 secondo tra il movimento nell area protetta e la generazione di allarme durante il quale Guardall VEx verifica il segnale Procedere con la verifica come segue a Accertarsi che la tensione di alimentazione sia compresa tra 9V e 16V dc b Abilitare il Led portando alto l ingresso TEST c La prima rilevazione di un sensore volumetrico causer un breve lampeggio del LED se l ingresso TEST alto E necessaria una seconda rilevazione entro 25 secondi per generare l allarme Nella versione Long Range tutte le rilevazioni causeranno una segnalazione di allarme d La regolazione della copertura orizzontale e verticale si esegue allentando il dado ad alette e regolando la testa del sensore come richiesto e Allentare il dado a
18. nt of the detector will cause significant changes in coverage b Preparation amp Mounting Decide on the mounting position and cable routing The recommended mounting height is 2 3 m 7ft Gin If required by the application the detector can be mounted at other heights and the head adjusted accordingly see section 3d Remove cover by slackening the cover screw do not remove the screw and pulling downwards at the screw end Lift the other end away from the cover locating clip Pull out connector block releasing the wires from the wire harness restraints Unscrewthe wing nut from threads and leave it captive on the wire harness Lift head off the mounting bracket and leave hanging on wire harness This exposes all three fixing holes Fit the mounting bracket to the wall using all three fixing holes see carton for mounting template and ensure correctorientation see picture on front of manual Re fithead to mounting bracket taking care to locate the O ring correctly Re fitthe wing nut but do not tighten Leave the wing nut and connector block loose c Wirin Run cable through the cable entry hole Ensure that the terminal block is pulled out of the mounting brackets Connect the wires to the empty side of the terminal block Select Normally Closed N C or Normally Open N O alarm contacts N C Default Yellow wire in middle position of connector block N O Replace yellow with purple floa
19. opf entsprechend einstellen e Ziehen Sie die Fl gelschraube fest nicht berdrehen und f hren Sie einen Gehtest des Erfassungsbereichs durch Versichern Sie sich da die Meldungen an der Zentrale angezeigtwerden Ordnen Sie die Kabel in die Kabelhalterungen und befestigen Sie den Bodendeckel indem Sie diesen sorgf ltig in die Deckelhalterung einsetzen bevor Sie die Schraube anziehen Die Reichweite und der Erfassungsbereich die gezeigt werden sind mit dem VEx 2 3m ber Boden mit dem gewinkelten Sensorkopf damit er einen Punkt 1m ber dem Boden bei der 15m Reichweite betrachtet installiert Dieses kann ndern wenn unterschiedliche Montageh hen oder Sensor kopfpositionen verwendet werden Stellen Sie sicher da die Sicht des Detektors nicht versperrt ist Pr fen Sie immer den Erfassungsbereich des Detektors w hrend der Installation 4 Selbsttests Periodischer Selbsttest Der Melder f hrt regelm ig einen internen elektrischen Selbsttest durch Falls dies einen Fehler aufweist leuchtet die LED innerhalb ca einer Stunde schwach auf Dieser Zustand wird entweder durch einen Alarm oder einen erfolgreichen Selbsttest zur ckgesetzt Test der Versorgungsspannung Die Spannung wird st ndig berwacht Falls diese erheblich unter 9 V f llt flackert die LED bei 1Hz 1x Sek zwischen hell schwach erleuchtet Dieser Zustand wird zur ckgesetzt sobald die Spannung zu gt 9 V zur ckkehrt 5 LED Anzeige Zu
20. per 3 secondi se il LED abilitato Self test fallito LED illuminato poco 6 Ricerca Guasti Nessuna indicazione Verificare che l ingresso TEST sia alto LED LED lampeggi Verificare che l alimantazione sia ante lento illum poco maggiore di 9V illum Attivit continua del Verifcare le sorgenti di luce o altre sorgenti PIR indicata dal LED di falsi allarmi limitrofi Poca rilevazione Verificare la regolazione della testa del sensore LED illuminato poco Fallito self test Verificare l operativit del sensore 7 Varianti W74302 Vex Vol 15 mt Volumetrico W74303 Vex LR 30 m Long Range 8 Garanzia Tutti i prodotti sono garantiti contro difetti di fabbricazione o di materiali Nell intento di apportare migliorie al design ed alla qualit dei prodotti Guardall si riserva il diritto di modificare le caratteristiche dei suoi prodotti senza nessun obbligo di preavviso Tutti i prodotti guasti o diffettosi vanno resi al proprio fornitore diretto Nota la Guardall raccomanda di verificare sempre che il rivelatore trasmetta alla centrale la condizione di allarme e che l installatore informi di ci il cliente DK Livello Guardall S r l Via Quasimodo 12 20025 Legnano MI Italy Tel 0039 0331 577677 E mail guardall guardall it Website www guardall it 1 Caract ristiques techniques Tension 9V 16V Consommation Typique 10mA Maximum 12mA Ondulation r siduelle 2V c c 12V R glage couve
21. rture 10 50 verticalement 90 horizontalement Indication LED Entr e test au 12V pour activer Gamme de temp rature 25 C 60 C Compensation de temp rature Compensation automatique de temp rature Contactsortie Libre de potentiel normalementferm e ou alarme normalement ouvert sur relais statique Pouvoir de coupure 50mA 30V avec r sistance de 10 Qen s rie Dur ealarme Environ 3 secondes Sortie auto Normalement ferm e libre de potentiel pouvoir protection de coupure 50 mA 30V Entr eTest Normalement basse au OV ou ouvert raccorder au 12V du d tecteur pour l activer haut doit avoir une masse commune avec le d tecteur Degr IP Conforme IP55 en respectant les normes d installation NE PAS RACCORDER AU 220V Les d tecteurs ont t con us selon les exigences de la TS 50131 2 2 2004 grade 2 classe 4 2 Pre Installation M me si le d tecteur VEx est destin un large vential d applications l installation doit tre effectu e dans les r gles de l art a Conseil d installation Il faut tenir compte des obstacles habituels pour viter les d clenchements intempestifs Rayons de soleil directs sur le d tecteur Zones de chaleur dans le champ couvert Installer le d tecteur sur un support stable Pr sence d objet ou d obstacles masquant la couverture b Pr paration et montage Installer le d tecteur une hauteur de 2 3m environ Une haut
22. t Trotzdem sollten normale professionelle Installationsrichtlinien beachtet werden a Vermeidung von Falschalarmursachen direkte Sonneneinstrahlung auf die Melderlinse starke W rmequellen im Erfassungsbereich Montieren Sie den Melder auf eine solide vibrationsfreie Grundfl che Gr ere Objekte im Melderbereich beeintr chtigen den Erfassungsbereich b Vorbereitung und Montage W hlen Sie Montageposition und Kabelf hrung Die empfohlene Montageh he ist 2 3m Falls erforderlich kann der Melder in anderer H he montiert und der Sensorkopf entsprechend angepa t werden s Abschnitt 3d Entfernen Sie den Bodendeckel indem Sie die Schraubelockern nicht entfernen und den Deckel vom Schraubenende aus herunterziehen L sen Sie das andere Ende vorsichtig aus der Deckelhalterung L sen Sie den Klemmenblock aus der Halterung und die Kabel aus der Kabelhalterung Schrauben Sie die Fl gelschraube los und lassen Sie diese lose auf den Kabeln sitzen L sen Sie den Sensorkopf aus der Wandhalterung und lassen Sie diesen lose h ngen Sie k nnen nun alle 3 Befestigungs l cher sehen Befestigen Sie den Wandhalter an der Wand mit Hilfe aller 3 Befestigungsl cher s auch Befestigungsplan auf dem Karton Beachten Sie die korrekte Ausrichtung des Melders s Foto auf der Vorderseite der Anleitung Setzen Sie den Sensorkopf wieder auf und beachten Sie dabei die korrekte Position des Dichtungsringes Setzen Sie die Fl
23. tate Newbridge Edinburgh EH28 8PL Scotland Technical Hotline 0131 333 3802 Website www guardall co uk 1 Specifiche Tecniche Alimentazione 9V a 16V dc Assorbimento Nominale 11mA a riposo a 12V dc Massimo 12mA in allarme a 12V dc Ripple Max 2V picco picco a 12V dc Copertura PIR 10 a 50 verticale 90 orizzontale Indicazione LED Abilitato con Ingresso Test alto Temperatura 25 C a 60 C Compensazione di temperatura Compensazione digitale Uscita allarme Normalmente Chiuso N C o Normalmente Aperto N O rel allo stato solido concontatti liberi da tensione Portata 30V dc 50mA con resistenza serie max 100 NC ALLARME Portata 24V dc 50 mA Ressistenza in serie massima 10 Durata Allarma Circa 3 secondi Uscita Normalmente chiuso contatti liberi da Manomissione tensione Portata 30V dc 50 mA Ingresso test Normalmente basso o aperto Portare a positivo per attivare Negativo in commune con l alimentazione del sensore Grado l P IP55 a condizione che l installazione sia eseguita a regola d arte ed in conformit alle istruzioni di installazione allegate Il sensore puo essere usato anche in ambienti non completamente chiusi NOTA NON UTILIZZARE PER COMMUTAZIONI RETE 220 V Il VEX ha i requisiti dello standard TS 50131 2 2 2004 Grado 2 Classe IV Nota la certificazione IMQ SISTEMI DI SICUREZZA non copre la verifica dei requisiti prescritti da tale norma 2 installazion
24. ting wire in middle position of connector block Fit the connector block onto its retaining pins Do not re fit the cover at this stage 3 Checking VEx Coverage Note that there will be a short delay less than 1 second between movement and a unit alarm being generated while the Guardall VEx verifies the intruder signature Proceed with coverage checks as follows a Ensure that the supply voltage is between 9V and 16V dc b Enable the LED by taking the Test Input high c The first detection on a volumetric unit will cause a short LED flash if Test Input is high Asecond detection within 25 seconds is required to generate a unit alarm All detections on a long range unit will generate a unit alarm d The vertical and horizontal coverage is adjusted by loosening the wing nut and moving the head as required e Tighten wing nut do not over tighten then walk test the protected area checking that alarms are indicated at the control panel Finally tidy the wires under the wire harness restraints fit the bottom cover taking care to fit the cover onto the locating clip before closing the screw end and tightening the screw The range and coverage shown is with the unit installed 2 3m above ground with the head angled so that it looks at a point Im above the ground at 15m range This may change if different mounting heights or head positions are used Ensure the detector s field of view is not obscured Always test the det