        Suction Unit CAMI New Emivac User Manual
         Contents
1.    SUCTION UNIT NEW EMIVAC       USER MANUAL    CE 0123    medical  suction       www medicalsuction co uk    NEW EMIVAC it   s a manual device to be used for the emergency field to be used for the aspiration of the body liquids  mucus  or catarrh or blood   Easily movable and designed for a manual use    Thanks to this characteristics and to the rating that it has product is particularly suitable for a emergency use  on the  thacheotomized patients  minor surgical applications and post   operative therapy at home    Made of highly heat resistant  in conformity with the latest European safety standard  the product is supplied with a  polycarbonate 0 4 litre autoclavable jar with overflow valve     GENERAL WARNING    f READ INSTRUCTION MANUAL CAREFULLY BEFORE USE       ONLY HIGHLY QUALIFIED STAFF USE RESERVED       THE INSTRUMENT MUST NOT BE DISASSEMBLED  FOR A TECHNICAL SERVICE ALWAYS CONTACT CA MI    IMPORTANT SAFETY RULES    1  Check the condition of the unit before each use    2  Respect the safety regulations indicated for electrical appliances and particularly      Use original components and accessories provided by the manufacturer to guarantee the highest efficiency and   safety of the device      The device can be used only with the bacteriological filter      Place instrument on stable and flat surfaces      Don   t touch the device with wet hands and always prevent the appliance coming into contact with liquids      Keep off the reach of children or not capable peop
2.   Suction tubes for insertion in the human body purchased separately from the machine should comply with ISO  10993 1 standards on material biocompatibility     CLEANING OF ACCESSORIES    To clean the plastic housing of the device wear disposable latex gloves and clean with denaturated alcohol or hypoclorite  solutions  Washing and   or cleaning the autoclavable jar as to be carried out as follows      Wear protection gloves and apron  glasses and face mask if necessary  to avoid contact with contaminating   substances      Disconnect the jar from the device     Disconnect all tubes from the jar and the protection filter     Empty and dispose of the Jar according to the laws in force in your country      Separate all parts of the cover  overflow valve  o ring     After disposing of disposable parts and disassembling the jar wash in running cold water and rinse thouroughly    Then soak in warm water  temperature shall not exceed 60  C   Wash thouroughly and if necessary use a non abrasive brush to  remove incrustations  Rinse in running warm water and dry all parts with a soft cloth  non abrasive     The jar and the cover can be autoclaved by placing the parts into the autoclave and running one sterilization stem cycle at  121  C  1 bar relative pressure  making sure that the jar is positioned upsidedown    Mechanical resistance of the jar is guaranteed up to 30 cycles of sterilization and cleaning at the indicated conditions    EN ISO 10079 2   Beyond this limit the physical 
3.  in its seat enscrew the cap and insert the seal properly in its seat    3  The Vacuum power on the    Protection filter blocked or Replace the filter  patient side is either very low or damaged Replace or reconnect the tubes  check the jar  absent    Connection tubes blocked  connections  kinked or disconnected Empty the jar  or disconnect the tube from     Shut off valve blocked or the jar and unblock the shut off valve   damaged The unit twill only work in the upright position      Pump motor damaged Refer to authorised service personnel  that the float i is not partial detached  material      6  Low suction o Low suction Foam inside the jar Fill the jar to   Fill the jar to 1 3 full of ordinary water o full of ordinary water    Faults 1 2 3 4 5 6 7 None of the remedies has Contact the seller or CA MI After sales Assistance  achieved the desired results Service       If the overfill security system fails  continued aspiration will be stopped by the bacteriological filter   Should this back up security also fail  there is a risk of penetration of liquid into the device  Don   t attempt to proceed with aspiration    under these circumstances     Return the device to CA MI for service   BEFORE EVERY CHECKING OPERATION  IN CASE OF ANOMALIES OR BAD FUNCTIONING  PLEASE CONTACT CA MI  TECHNICAL SERVICE  THE MANUFACTURER DOES NOT GIVE GUARANTEE IF INSTRUMENT  AFTER THE TECHNICAL  SERVICE CHECKING  APPEARS TO BE TAMPERED    INSTRUCTIONS      Connect the short silicon tube with anti
4. EMIVAC    FLOW DIRECTION  eS    IN   Fluid Inside  Suction pump Inlet    Jar Air Tube    RULES FOR RETURNING AND REPAIRING    UNDER NEW EUROPEAN RULES  CA MI REQUIRES THE FOLLOWING PROCEDURES TO BE CARRIED OUT TO PROTECT  THE   INSTRUMENT AND THE SAFETY OF ALL WHO COME IN CONTACT WITH IT    CA MI warrants it   s product for 24 months after purchasing date    Before returning an instrument for repair  the external surfaces and all accessories MUST be carefully disinfected with a cloth  soaked in methylated spirits or hypochlorite based solution  The instrument and accessories should then be placed in a bag  with a note outlining the disinfection undertaken    Failure to follow this procedure will result in the instrument being returned to the purchaser unrepaired    Instruments returned for repair MUST be accompanied by a description of the problem  CA MI will not be responsible for  damage caused through improper use  To avoid such damage  please read the instruction carefully    Where CA MI determines that an instrument is faulty  a replacement will be provided only if a SALES RECEIPT and STAMPED  GUARANTEE are provided  CA MI will not be responsible for damage accessories  These may be replaced at the customer   s  expence    CA MI warrants it   s products for 24 months after purchasing date  In front of this warranty  CA MI will be obliged only to repair  or substitute free of charge the products or parts of them that  after verification effected on our factory  or our aut
5. RT Room temperature   40  70  C  Room humidity percentage  10   100  RH    SYMBOLS    Class II isolation equipment  CE marking in conformity with EC directive 93 42 EEC and subsequent  changes    Warning  consult the instruction manual  Keep in a cool  dry place             Conservation temperature   40   70  C    Type B equipment    DEHP Phthalates  Suction catheter        2  www medicalsuction co uk    ACCESSORIES SUPPLIED    DESCRIPTION  COMPLETE ASPIRATION JAR 400cc  CONICAL FITTING    TUBES SET 6 mm x 10 mm    HYDROPHOBIC AND ANTIBACTERIAL  FILTER       The filter is produced with  PTFE  hydrophobic material to prevent fluids entering the pneumatic circuit    It should be changed immediately if it becomes wet or if there is any sign of contamination or discolouration    If should also be changed if the unit is used with a patient whose risk of contamination is unknown    Don   t use the suction unit without the protection filter  If the suction unit is used in an emergency or in a patient where the  risk of contamination is not know the filter must be changed after each use     WARNING  Suction tubes for insertion in the human body purchased separately from the machine should comply with ISO  10993 1 standards on material biocompatibility     WARNING  The medical device is provided without a specific suction probe  If this device must be used with a specific suction  probe  the end user is responsible for making sure it complies with the EN 10079 2 regulation     WARNING
6. bacterial filter to the suction connector   The other tube  with one end connected to the filter must be connected with the other end to the jar s lid connector   where has been fixed the red float  When the 90  of the volume of the jar is reached there is the activation of the security  float the float close the aspiration connector on the jar  to avoid liquid penetration inside the device    The device must be used on a plan of horizontal operation        WARNING  Ensure that the FLUID SIDE or IN marker on the filter is on the side facing the collection jar lid and fitted into the     VACUUM    A wrong connection causes immediate destruction in case of contact with sucked liquids     Connect the long silicon tube to the other jar s lid connector     Connect the other end of the long silicon tube to the probe plastic connector then connect the suction probe to it      Unscrew the jar s lid and fill the jar 1 3 full or ordinary water  this for an easy cleaning operations and an rapid reaching  of the functionality vacuum  the rescrew the lid on the jar correctly      Push foot to start suction      To extract the accessories and start with cleaning as write in the clean chapter       A  www medicalsuction co uk    A    NEVER USE THE DEVICE WITHOUT JAR AND   OR PROTECTION FILTER    MAKE SURE THAT CHILDREN AND OR MENTALLY ILL PEOPLE DO NOT USE THE DEVICE WITHOUT ADULT  SURVEILLANCE    ALWAYS PLACE THE DEVICE IN POSITIONS FOR EASY DISCONNECTION     Filter Assembling    Mod  NEW 
7. horized  Service Center  by the Technical Service  results defective    The warranty  with exclusion of responsibility for direct and indirect damages  it is thought limited to the solos defects of  material or workmanship and it stops having effect when the device results however gotten off  tampered or sheltered out of the  Factory or from the Authorized Service center    The commodity always travels to risk and danger of the buyer  without any responsibility of CA MI for damages caused by the  transport or dismay from the vector     5  www medicalsuction co uk    
8. ion co uk    A    IMPORTANT INFORMATION FOR CORRECT DISPOSAL OF THE PRODUCT IN ACCORDANCE WITH EC DIRECTIVE 2002 96 EC     In respect of art  13 Decreto Legislativo 25 Luglio 2005  n 151    Actuation of European directives 2002 95 EC  2002 96 EC and  2003 108 EC  for reduction in use of dangerous substances in the electric and electronic device and for garbage disposal      The symbol as over applied on the device or its packaging means that at the end of its useful life the product must not be disposed of  with domestic waste  At the end of device useful  the user will must deliver it to the able collecting centres for electric and electronic  garbage  or give back to the retailer in the moment of equivalent new device purchasing  one against one  Disposing of the product  separately prevents possible negative consequences for the environment and for health  deriving from inadequate disposal  It also  allows the recovery of materials of witch its made up in order to obtain an important saving of energy and resources and to avoid  negative effects to the ambient and health  In case of abusive disposal of device by user  will be applied administrative endorsements in  compliance with current standard     TECHNICAL CHARACTERISTICS          MAXIMUM SUCTION FLOW  without jar     SICILICONE TUBE SIZE  ACCURANCY OF VACUUM INDICATOR  WORKING CONDITION Room temperature  5  35  C   Room humidity percentage  30   75  RH    Altitude  0   2000m s l m     CONSERVATION CONDITION AND TRASPO
9. le without supervision      Preserve and use the medical device in environments protected from atmospheric factors and at a distance from   heat sources      Don t use the device thoracic drainage    3  For repairs  exclusively contact technical service and request the use of original spare parts    Failure to comply with the above can jeopardise the safety of the device    4  Use only for the purpose intended  Don   t use for anything other than the use defined by the manufacturer    The manufacturer will not be responsible for damage due to improper use    5  Instrument and accessory discharging must be done according to current regulations in the country of use    6  None of mechanical parts have been designed to be repaired by customers or end users  Don   t open the device  do not  mishandle the electric   mechanical parts  Always contact technical assistance   7  Using the device in environmental conditions different than those indicated in this manual may harm seriously the safety  and the technical characteristics of the same     The manufactured cannot be held liable for accidental or indirect damages should the device be modified   repaired without authorization or should any of its component be damaged due to accident or misuse     Any minimal modification   repair on the device voids the warranty and does not guarantee the  compliance   with the technical requirements provided by the MDD 93 42 EEC  and subsequent changes  and its  normatives     1  www medicalsuct
10. mechanical characteristics of the plastic may decrease and replacement of  the part is therefore recommended    After sterilization and cooling at environment temperature of the parts make sure that these are not damaged    Assemble the jar as follows      Place the overflow valve into its seat in the cover  under VACUUM connector      Insert floating valve keeping the o ring towards the opening of the cage     Place the o ring into its seat around the cover     After completing assembling operations always make sue that cover seals perfectly to avoid vacuum leackages or   liquid exit   The aspiration tubes can be sterilized on autoclave using a sterilization cycle at 120  C  The conical connector can be sterilized  on autoclave using a sterilization cycle at 121  C  The device is ready for anew employment now     A    DO NOT WASH  STERILIZE OR PUT IN AUTOCLAVE THE ANTIBACTERIAL FILTER    3  www medicalsuction co uk    MAINTENANCE    The NEW EMIVAC suction equipment does not need maintenance or lubrication    It is necessary to check functioning and instrument before every use    Unpack the instrument and always check integrity of plastic parts  they might have been damaged during previous use   Close the aspirator outlet with your finger    Press the foot and check vacuum functionally       Faulttye   Case                   CSCSCSCSCSSluttitom          lt    1  No aspiration Jar Cap badly screwed down Unscrewed the cap  then rescrew it correctl  2  No aspiration Lid seal not
    