INSTALLATION MANUAL Ceiling Panel - Amp Air

image

Contents

1. ceiling Fig 6 Push the panel fixing bracket Insufficient tightening of the screws may result in the securely following problems Tighten the screws securely The height of the indoor unit can be Panel fixing screw adjusted from the corner holes of the Lift th parielii ner frame to make Air leakage ceiling panel without detaching the P n the screw head visible panel provided that the levelness of Alrleakage the indoor unit and the drain pipe are from bottom th Fi 6 of the ceiling not affected g EZ ra 0 No gap 0 0 Dew drop water leakage Indoor unit 0 Contamination A Ifa gap between ceiling panel and gt bottom of the ceiling still remains after o the screws are tightened readjust the Bottom of ceiling Ceiling panel height of the indoor unit Tighten the panel fixing screw After the adjustment of height tighten the nuts of the indoor unit securely Wire Connection For illustrative purpose the orientation of the indoor unit is not the actual orientation E Connecting wires of Ceiling Panel 1 Remove the two screws of the electric parts box cover and detach the electric parts box cover by pressing the hook The electric parts box cover is clamped onto the hinge 2 Pass the louver motor wire from the ceiling panel through the clamper as shown and connect the wire to the white 20P connector CN510 on the P C board of the indoor unit
2. Connect the wire firmly to the connector to ensure operation of the louver 3 Attach the electric parts box cover by reversing the procedure of detaching Make sure that no wire is caught between the electric parts box and the cover e Make sure that no wire is caught between the indoor unit and the ceiling panel Electric parts box cover Two screws Clamper Pass the wire through the clamper as illustrated E Attaching Adjust Corner Caps and Air Inlet Grille e According to customer requirements the grille orientation of the air inlet grille and the location of the company name indication on the adjust corner cap can be changed as shown in the figure right for installation of multiple units However the Wireless Remote Controller Kit separate sold parts can be installed only at the diagonal corner of the drain pipe of the indoor unit If the Kit is installed at another location it may cause malfunction of the Kit Attaching adjust corner caps 1 Hook the strap of the adjust corner cap securely to the pin of the ceiling panel 2 Attach the adjust corner caps to the ceiling panel Insert the two claws of the adjust Press the cap in the directions of corner cap into the rectangular holes arrows so that the three claws are of the ceiling panel in the direction of fitted arrow A Claws CAUTION e Push the three claws of the adjust corner cap firmly as far as they will go Failure to
3. do so may result in water leakage Bland name indication given at factory shipping Adjust corner cap Can be attached at any location Refrigerant i Indoor unit electric parts box pipe side Wireless Remote Controller Kit separate sold parts Can be installed only at this location Drain pipe side Locations of air inlet grille hook knobs attached when the product was shipped These knobs can be attached on any side of the four sides but attaching them on this side is recommended Attaching air inlet grille Rectangular j SN e Attach the air inlet grille by reversing the procedure of its removal The air inlet grille of this ceiling panel can be attached in four patterns by turning the grille Select the orientation of the grille for alignment when multiple ceiling panels are attached or according to customer requirements Attach the air inlet grille so as not to catch the louver motor wire Be sure to attach the safety strap of the air inlet grille to the ceiling panel Hook hole of ceiling panel Safety strap 3 Other Descriptions Checks after Installation e Reconfirm that there is no gap between indoor unit and ceiling panel or between ceiling panel and bottom of ceiling Such gap may result in water leakage or dew drop e Confirm that all wires are connected correctly and firmly Otherwise the louver does not work e Confirm that the claws of the ad
4. TOSHIBA INSTALLATION MANUAL Ceiling Panel MODEL RBC U31PG W E U31PG WS E Precautions for Safety e The product and this manual are provided with important safety notices to ensure safe use and protect the user and other people from hazards and preclude damage to property Be sure that you fully understand the following contents expressions and graphic symbols and read this manual carefully Always observe the precautions WARNING e Ask an authorized dealer or qualified installation professional to install the ceiling panel Inappropriate installation may result in water leakage electric shock or fire if you install it by yourself e Carry out an installation work securely according to this Installation Manual Inappropriate installation may result in water leakage electric shock or fire Attach the ceiling panel on a ceiling that withstands the weight of the ceiling panel Insufficient strength may cause a fall of the unit which may result in injury e Electrical work must be performed by a qualified electrician in accordance with the Installation Manual Make sure the air conditioner uses an exclusive power supply The capacity shortage of the power circuit or improper electrical work may result in electric shock or fire e Connect the specified wires firmly and clamp them securely so that external force applied to the wires does not affect the connector pins Improper wire connection or clamping may result in fire or malfun
5. aching the ceiling panel as it may cause malfunction of the louver 1 Insert the two movable hooks at the inside of the ceiling panel into the rectangular holes of the indoor unit and hook them tentatively onto the indoor unit Fig 1 and Fig 2 The ceiling panel has an orientation to the indoor unit for installation Attach the ceiling panel so that the louver motor wire comes to the electric parts box side To detach the ceiling panel push the movable hooks outward while holding the ceiling panel 2 Lift the corner of the panel inner frame and insert the panel fixing screw of the indoor unit into the panel fixing bracket hole Fig 3 Then slide the panel fixing bracket in the direction of arrow and push it to the specified position Fig 4 Repeat this procedure for the four panel fixing Rectangular hole of brackets indoor unit X e Slide the panel fixing bracket while keeping the screw head lower than the bracket Push when releasing The panel fixing screws have been attached to the indoor unit since its shipping Movable hook 3 Tighten the four panel fixing screws to secure the ceiling panel until it comes into close contact with the indoor unit Fig 3 Fig 4 Fig 5 Panel inner frame Panel fixing bracket 4 Check that the ceiling panel is in close contact with the ceiling e Make sure that there is no gap between indoor unit and ceiling panel and between ceiling panel and bottom of the
6. ction e Be sure to connect earth wire grounding work Do not connect the earth line to a gas pipe water pipe lightning conductor or a telephone earth line Incomplete earthing may result in electric shock e Never modify or repair the product Incomplete modification or repair may result in electric shock or fire CAUTION e Wear heavy work gloves during the installation work to avoid injury Components Part name Ceiling panel Installation manual REQUIREMENT Quantity 1 1 Do not apply excessive force to Shape the louver as it may cause a malfunction Louver This manual 1 Preparation for Attaching Ceiling Panel E Checking Indoor Unit Position 1 Check the position of the indoor unit using the Installation Manual 2 Check whether the ceiling opening size falls within a range of 860 x 860 to 910 x 910 3 Determine the positional relation between the ceiling and the indoor unit using the installation gauge supplied with the indoor unit Improper positioning of the indoor unit may result in air water leakage or malfunction of the louver Do not put the ceiling panel facing down or lean it against a wall etc or put it on an object with projection to avoid scratches on the surface Handle the ceiling panel carefully so as not to deform the movable hooks This clearance must be 12 to 17 A clearance outside this range may cause malfunction Indoor unit 12 to 17 In
7. just corner caps are fitted securely Improper fitting may result in water leakage When Using Wireless Remote Controller e For details of the installation refer to the Installation Manual supplied with the Wireless Remote Controller Kit separate sold parts Delivery to Customer e When the installation work has been completed execute a test run to check for normal operation Then explain how to use and maintain the ceiling panel to the customer according to the Owner s Manual of the indoor unit Ask the customer to keep this installation manual with the Owner s Manual and Installation Manual of the indoor unit 4 EH78970601 EN
8. stallation gauge supplied with the indoor unit 2 Attaching Ceiling Panel to Indoor Unit E Detaching Air Inlet Grille 1 Slide the knobs of the hooks of the air inlet grille in the direction of arrow 1 and open the grille Release the safety strap hook from the ceiling panel Do not remove the safety strap screw on the air inlet grille side Remove the hinges on the air inlet grille from the ceiling panel in the direction of arrow 2 with the grille open E Detaching Adjust Corner Caps 1 Pull the knob of the adjust corner cap in the direction of arrow 1 and detach the adjust corner caps from the four corners The knob is provided only on one side of the cap Detach the adjust corner caps from the knob side E Checking Panel Fixing Bracket Position After the adjust corner caps are detached check that the panel fixing bracket is open Fig 1 The ceiling panel cannot be attached to the indoor unit with the bracket closed Fig 2 Open Closed Keep the bracket open Panel fixing i bracket i 4 Open Fig 1 Air inlet grille Ceiling panel Safety strap hook Hinges Adjust corner cap Adjust corner 7 cap Strap Ceiling panel E Attaching Ceiling Panel Fig 1 Drain pipe Rectangular holes of lt J indoor unit Electric parts box Do not apply excessive force to the louver when att