Home
Installation Manual for D156X Series Constant Voltage Power
Contents
1. Less than 100mV less than 0 7 13 7v Product part numbers PB box CP box samp bss DISCS With 8 fused outputs samp Dexs Dx With4BNC i O With 4 BNC D1565 4BNC C Sizes and weights Size h x w x d mm 260 x 320 x 87 430 x 3455 x 90 3 2 4 5 Weight ko Oo e All units are fused in the 230V AC supply The D156X Series power supply fuses require no user intervention D156X Series Constant Voltage Installation Manual D156X INST 10B v1 3 Green Orange Red P 0 28 0 6 1565 12CV SA AC supply N 3 1 Sives N UJ lt Battery Tamper 12V power Voltage adjuster connectors connector output 4 BNC connector 8 way splitter Power supply Diagram showing the PSU and either the 4 BNC connector or the 5 way splitter in the box In case of problems telephone Dycon Technical Support on 44 0 1443 471 064 or email technical dyconsecurity com D156X Series Constant Voltage Installation Manual D156X INST 10B v1
2. to the system The green LED or orange standby battery LED indicates that the 12V is available from these terminal blocks Auxiliary power supply batteries These power supplies are compatible with 7AH or 8AH Sealed Lead Acid or Gel batteries which are connected to the BAT1 and BAT2 terminals The orange standby LED marked with a battery symbol indicates when AC power is off and power is being supplied by the batteries Two batteries must be used for the unit to function correctly in battery standby mode Output protection The output is protected by resettable fuse Should the output be overloaded and the fuse trip the red fuse fault LED marked with a battery symbol will be lit The fault can be reset by removing the short and re applying power after a minute to allow the fuse to cool Battery protection The batteries and electronic circuitry are protected against reverse polarity connection by a self resetting electronic fuse Voltage adjustment The output voltage can be varied from 12VDC to 15VDC by an adjustment using the potentiometer and measuring the output using a suitable meter The voltage will remain constant at the selected value even when running on battery power only D15X8 output splitter The D15X8 is designed to connect to any Dycon D156X Series ungraded power supply to provide up to 8 individually fused outputs The D15X8 is supplied fitted with 8 fuses rated at 1 2 Amp plus 2 fuses rated at 1 Amp in a spar
3. ad Dycon Installation Manual for D156X Series Constant Voltage Power Supplies Variable Output 12V 15V DC D156X Series D1565 X 8 5A fitted with 8 way output splitter D1565 4BNC DA fitted with 4 way power splitter and 4 loop through BNC connectors INSTALLATION Mount the metal enclosure onto the wall Connect the Live Earth and Neutral terminals to an un switched fused spur Connect the tamper outputs to the control panel as appropriate see control panel manuals for details Connect the 12v power output to the system Fit the two batteries to the BAT1 and BAT2 connections NOTE This unit requires 2 12 volt batteries to operate correctly in battery backup mode Switch on the AC supply and confirm that the green LED is lit meaning that mains supply is healthy Dycon Ltd Tel 44 0 1443 471 060 Fax 44 0 1443 479 374 Cwm Cynon Business Park Mountain Ash CF45 4ER UK www dyconsecurity com info dyconsecurity com External power supply AC supply The power supply has a three way terminal block for Live Earth and Neutral connections and is protected by a 20mm anti surge fuse Mains earth is isolated from the OV output although when supplied boxed mains earth is connected to the metal enclosure Tamper output This voltage free output is connected to the tamper switch These terminals will be shorted when the tamper switch is closed 12V power output Terminal blocks are provided to connect
4. es bag The installer may fit any combination of fuses provided that the overall load does not exceed that provided by the power supply Example a D1565 could support outputs 1 to 6 1 2 A and outputs 7 and 8 1A 5A in total A red LED is provided for each output which lights if the relevant fuse ruptures In addition a gi LED is provided which lights when the input voltage is present A 2 way Molex connector is provided to connect a remote LED to indicate if ANY fuse fails Indmidua Fuse a gt Eang i j Fad indications Com i T Cannector for Remote oba Fuse a Fad Indeation i inout voltage Se ee a os Present ricatta Pune Protected Ay k t rati Ouiputs Power Sapphy D156X Series Constant Voltage Installation Manual D156X INST 10B v1 2 D15X4 BNC This splitter allows power to up to 4 cameras and loop through connections for signals Individual fuse fail indications Connector forremote global fuse fail indication Fuses gt Fuse protected outputs 12v inputfrom power supply Maintenance This unit is only to be used by qualified service personnel there are no user serviceable parts No maintenance is required other than routine periodic testing and replacement of the standby batteries For further information on routine battery replacement please contact your battery supplier or manufacturer Specifications 230v 10 15 50Hz 15
Download Pdf Manuals
Related Search
Related Contents
Approx appPB3500B HDB-DOS User Manual (Cloud-9) - TRS Bedienungsanleitung deutsch - JS 要求水準書(PDF:1.8MB) Copyright © All rights reserved.
Failed to retrieve file