1. to insert the batteries Slide the remote controller into the 1 Open the back cover of the remote controller holder from the top remote controller by sliding it in the direction of the arrow 2 Insert the attached dry cell batteries Properly insert set the batteries by matching the and Fix the remote controller holder with polarity marks as indicated i the screws Then close the cover as before e S I RECEIVER INSTALLATION 1 Preparations before installation Install this kit after electric wiring the indoor unit Remove the suction grille air filter partition plate and decorative side panel right hand referring to the installation manual provided with the indoor unit 2 Remove the steel wire and electric parts box lid referring to the installation manual provided with the indoor unit 2 Determination of address and MAIN SUB remote controller If setting multiple wireless remote controllers to operate in one room perform address setting for the receiver and the wireless remote controller This is needed too for individual remote control in the group control mode for the group control mode see the installation manual provided with the indoor unit If setting multiple wired remote controllers in one room change the MAIN SUB switch of the receiver SETTING PROCEDURE 1 Setting the receiver Referring to the table below set the wireless address switch SS2 on the transmission PC board Wir
2. INSTALLATION MANUAL Wireless Remote Controller Kit MODELS BRC7C62 BRC7C67 READ THESE INSTRUCTIONS CAREFULLY BEFORE INSTALLATION KEEP THIS MANUAL IN A HANDY PLACE FOR FUTURE REFERENCE CONTENTS SAFETY CONSIDERATIONS ini pim 1 BEFORE INSTALLATION GH asias 1 REMOTE CONTROLLER INSTALLATION EE 2 RECEIVER TING TATA MON iS 2 FIELD SETTING rasa ra Ati 5 TEST OPERATION GEB SA da 6 SAFETY CONSIDERATIONS Please read this SAFETY CONSIDERATIONS carefully before installing air conditioning equipment and be sure to install it correctly After completing the installation make sure at start up operation that the unit operates properly Please instruct the customer how to operate the unit and keep maintenance Meaning of caution symbols CAUTION If the caution is not observed it may cause injury or damage to equipment NOTE user These instructions will ensure proper use of the equipment A CAUTION Refer also to the installation manual attached to the indoor unit and the installation manual attached to the decoration panel e Confirm that following conditions are satisfied prior to installation Ensure that noting interrupts the operation of the wireless remote controller Ensure that there is neither a source of light nor fluorescent lamp near the receiver Also ensure that the receiver is not exposed of direct sun light Ensure that the operaiton display lamp and other indicators are easy to see e The installa
3. ction Range Setting 1 C 0 5 C NOTES 1 The SECOND CODE NO is factory setto 01 However for the following cases itis setto 02 e Air Flow Direction Range Setting 2 Do not use any settings not listed in the table 3 For group control with a wireless remote controller initial settings for all the indoor units of the group are equal For group control refer to the installation manual attached to the in door unit for group control MODE NO FIELD SET MODE SECOND CODE NO FIRST CODE NO TEST OPERATION e Perform test operation according to the instructions in the installation manual attached to the indoor unit e After refrigerant piping drain piping and electric wiring operate according to the table to protect the unit PRECAUTIONS Refer to malfunction diagnosis label attached to the unit it if does not operate Operation Open gas side stop valve Open liquid side stop valve Electrify crank case heater for 6 hours Set to cooling with the remote controller and push ON OFF button to start operation Push ves TEST button twice and operate in TEST OPERATION mode for 3 minutes Push SWING button and confirm its operation Push button and operate normally Confirm its function according to the operation manual 3PA59585 16N EM98A004 09804 ten
4. eless address switch SS2 When using both a wired and a wireless remote controller for 1 indoor unit the wired controller should be set to MAIN Therefore set the MAIN SUB switch SS1 of the receiver to SUB 2 Setting the address of wireless remote controller It is factory setto 1 Setting from the remote controller 1 Hold down the button and the aer TEST button for at least 4 seconds to get the Field Set mode Indicated in the display area in the figure at right 2 Press the button and select a multiple setting A b Each time the button is pressed the display switches between A and b 3 Press the button and V button to set the DOWN address Address can be set from 1 to 6 but set it to 1 3 and to Address same address as the receiver The receiver does not work with address 4 6 4 Press the button to enter the setting 5 Hold down the button for at least 1 second to quit the Field Set mode and return to the normal display Multiple setting Multiple settings A b When the indoor is being operating by outside control central remote controller etc it sometimes does not respond to ON OFF and temperature setting commands from this remote controller Check what setting the customer wants and make the multiple setting as shown below Remote controller indoor unit To control other air conditions and units Multiple setting Remote co
5. he indoor unit setting may have to be changed Refer to the instruction manual optional hand book fc each optional accessory Procedure 1 When in the normal mode push the button for a minimum of four seconds and the FIELD SET MODE is entered 2 Select the desired MODE NO with the MODE button 3 Pushthe A button and select the FIRST CODE NO Pushthe Y button and select the SECOND CODE NO DOWN 5 Push the RESERVE button and the present settings are SET 6 Push the X TEST button to return to the NORMAL MODE Example If the time to clean air filter is set to Filter Contamination Heavy set Mode No to 10 FIRST CODE NO to 0 and SECOND CODE NO to 02 FIRST SECOND CODE NO NOTES 1 SODE NG DESCRIPTION OF SETTING S Filter Contamination Heavy Light Setting for spacing time of display time to clean air filter f Setting for when filter contamination is Long Life Light APProx heavy and spacing time of display time to Filter 2 500 hrs 1 250 hrs clean air filter is to be halved Spacing time of display time to clean air filter count f 8 Setting for when the filter sign is not to be displayed Display Do not display 4 ON OFF input from Outside Setting for when forced Forced Off ON OFF ON OFF is to be operated from outside Operation Thermostat Differential Changeover Setting for when 2 using the remote sensor Air Flow Dire
6. ntroller display For other than on left Commands other than ON OFF and temperature A Standard All items displayed setting accepted 1 LONG BEEP or 3 SHORT BEEPS emitted Operations remain displayed b Multi System shortly after execution All commands accepted 2 SHORT BEEPS 3 Stick the Unit No iabel at decoration panel air discharge outlet as well as on the back of the wireless remote controller PRECAUTIONS Set the Unit No of the receiver and the wireless remote controller to be equal If the settings differs the signal from the remote controller cannot be transmitted Unit No label 3 Setting up the wireless display cover and the transmission PC board 3 1 Remove the nameplate stand part of the DAIKIN mark of decoration panel 1 Insert a screwdriver in the rectangular hole in the rear 2 To remove the nameplate stand face downward and of the decoration panel and release the latch turn Rectangular Pin J Turn Fasten the harness passed through the rectangular hole to the rear surface of the decoration panel with the plastic clamp 4 Block the hole in which the screwdriver was inserted in step 1 with a sealing pad 3 2 Install the receiver ass y Pass the receiver ass y harness through the 3 rectangular hole long in the recessed portion where the nameplate stand had been installed 2 Hook the groove of the receiver ass y on the pins on both sides of the
7. recessed portion and install by turning Plastic clamp Rectangular hole Sealing pad 3 3 Install the transmission PC board on the indoor unit s electric parts box 1 Pull open the electric parts box 2 Using the PCB support install the transmission PC board at the position shown in the figure on the right 3 Connect the connector X2A on the transmission PC board to the connector X23A on the indoor unit s PC board with the wire harness Clamp the excess harness with a clamp 4 SETTING UP THE INDOOR UNIT BODY AND DECORATION PANEL According to installation manual provided with the indoor unit install the indoor unit and decoration panel 5 Wiring to indoor unit e Connect the receiver ass y s harness to the transmission PC board 1 Loosen the clamp on the side of the electric patrs box transmission wiring side and pass the harness from the receiver ass y 2 Pass the harness through the hook so it doesn t pass over the top of the PC board and connect it to the connector X1A on the transmission PC board Take up the slack in the harness inside the electric parts box and once again clamp it with the clamp on the side of the electric parts box Clamp transmisson wiring side 6 SETTING UP THE SUCTION GRILLE e According to installation manual provided with the decoration panel install the suction grile FIELD SETTING If optional accessories are mounted on the indoor unit t
8. tion position of this kit is 1 position of the decoration panel Therefore confirm that its position is set so that the single form the wireless remote controller can be easily transmitted and its display can be easily seen BEFORE INSTALLATION ACCESSORIES Check if the following accessories are included with your unit Unit No label 1 set Dry cell battery Plastic clamp amp Receiver ass y Plastic clamp installation screw 2 pcs LRO3 AM4 E x o Transmission PC board 1 pe os PCB support ax 1 pc j Screw for or Wireless remote controller Sealing pad Operation manual Q Remote controller holder installing remote controller holder NOTE TO THE INSTALLER Be sure to instruct the customer how to properly operate the system showing him her the attached operation manual REMOTE CONTROLLER INSTALLATION Installing wireless remote controller e Do not throw the remote controller or impose large shocks Also do not store where it may be exposed to moistture or direct sunlight e When operating point the transmitting part of the remote controller in the direction of the receiver e The direct transmitting distance of the remote controller is approximately 7 meters e The signal cannot be transmitted if something such as curtains blocks the receiver and the remote controller e Installing to a wall or a pillar e How