Home

INSTALLATION MANUAL

image

Contents

1. 1 Connecting the drain hose EUN EA QO I fia 1 A Warning Proceed as follows to install a condensate pipe to drain condensate If the device is used in areas formed in the compact unit during operation where the temperature can re main below zero for 2 to 3 days Use a drain hose with an internal diameter of 15mm condensate pipes should not be Connect the drain hose to the compact unit used as the condensate could freeze which can cause mal Lay the drain hose with a downward slope For long drain hoses functions use a metal support if necessary to prevent the hose bending Lay the drain hose so that closures or blockages cannot occur Do not insert the drain hose in a waste water system from which aggressive gasses such as ammonia gas sulphur gas etc can escape o e oe SS E o 53 Ss I E Aquarea air water heat pump Installation manual for compact systems 03 2013 6 21 Electrical installation Panasonic ideas for life 7 Electrical installation Correct 10mm 1 The insulation must be at least 10mm 1mm in length Ensure that all strands are clamped Danger The work may only be performed by qualified or certified personnel Ensure that you have disconnected the power supply before you per form installation work Secure the power supply to prevent unintentional reactivation Ensure that all cable
2. 8 Commissioning 8 1 Commissioning Danger Only qualified or certified personnel may work on the open device The device carries potentially fatal voltage when open Ensure that you do not touch any live device parts 1 Manometer 3 2 Water recirculation pump alte Figure shows standard f uu M a B perp leo Go 8 2 EC 4 l Cc MEER 1 Fastening screws 2 Lever 3 Pressure relief valve 4 Raise lever Pressure relief valve Open the compact unit as described in Section 5 Vent the heating system Proceed as follows to do so Loosen the fastening screws as shown in the figure and remove the cover Set the lever of the pressure relief valve to the horizontal position open The enclosed air can now escape 8 34 Aquarea air water heat pump Installation manual for compact systems 03 2013 Panasoni
3. All installation work for the water circuit must comply with all relevant European and national regulations including EN 61770 The compact unit is only intended for external installation and may not be installed indoors Use only enclosed or specified parts f the compact unit is to be installed close to the sea in highly sulphurous regions or regions with high oil contents e g machine oil etc its service life may be reduced 2 4 General further information o0 NOTE The following information provides recommendations or advanced assistance Air water heat pumps require planning permission in Wales and Northern Ireland and must meet certain criteria in England and Scot land to be classed as a permitted development If in doubt check with your local planning office For details on preventing water pipes freezing and heat and cold protection see the WRAS guidelines and BS EN 806 and BS 6700 he design handbook for split systems and compact systems contains further information on the device Aquarea air water heat pump Installation manual for compact systems 03 2013 2 9 Device overview Panasonic Components E ideas for life 3 Device overview 3 1 Components Component name Connection name 1 Electronic circu
4. Note All settings are preserved in the event of a power failure stored in EPROM The weekday and time are buffered by a battery for roughly 36 hours after which they must be set again Commissioning Programming Special functions Reset to factory settings 10 Switch on delay of the electric im 13 Sterilisation temperature mersion heater for hot water 20 min 40 to 75 C Standard 70 C to 1 hour 35 min Standard 1 hour Setting the temperature to be used Setting the delay period before the im for sterilisation mersion heating is switched on for the hot water tank if the tank temperature is not reached 11 Sterilisation YES NO Standard 14 Sterilisation duration 5 min to YES Setting for sterilisation of the 1 hour Standard 10 min Setting hot water the period required to retain the tank temperature required for sterilisation Bias SERVICE 12 Day and time of sterilisation Standard Monday 12 00 noon Setting day and time of the weekly sterilisation CORO aE ACTUAL WATER Die OFF ON T STATUS MODE CHECK Q 24 QUIET HEATER SEARCH SEARCH Dx wy ERROR RESET Pe Press the three marked operating buttons simultaneously for 5 seconds to reset to the factory settings Aquarea air water heat pump Installation manual for compact systems 03 2013 8 43 CO 2 E E O O Commissioning Programming Setting the weekly timer
5. et C NC fF Go10 oc SETTING JA SET MODE CHECK ce am A QUIET HEATER SEARCH e Vy ERROR RESET e SERVICE DEFROST SETTING g STATUS SERVICE 25 24 23 Button assignment 17 Operation button ON OFF 18 Operating mode selection button Use this button to select the operating mode required 19 System status buttons These buttons are used for a series of status queries Proceed as follows Press the CHECK button for 5 seconds to switch to Status mode Press the UP or DOWN button to open the following values 1 Compressor operating frequency 2 Error code 3 Water inlet temperature 4 Water tank temperature Press the CANCEL button or wait 30 seconds to quit Status mode 20 Service button This button takes you to menu items Sr 01 for pump down mode and Sr 02 for circulation pump You can toggle between the two menu items using the SEARCH arrow buttons 22 21 Button for enabling the additional elec tric heater for the heat pump The addition al electric heater can only be user if this button is pushed Note If this button is not pressed the additional electric heater for the heat pump is only used for Defrosting Device startup Frost protection mode 22 Emergency heating mode button This button allows the device to be operated in emergency heating mode with the CO additional electric heater for the heat pump e g if the heat pump is defe
6. 11 Appendix Commissioning report Company name Panasonic ideas for life uM Machine type Refrigerant Fill quantity Hydraulic system Supply return connected correctly Yes _ No System flushed and vented Yes No Filter in return Yes No Hydraulic compensation performed Yes No Filter lockable Yes No Expansion tank set Yes No Directional valve set correctly AB return water Yes No B to tank Ves No Buyer Invoice address Input pressure in bar System depressurised Yes No Electrical connections A to heating Yes No Storage tank vessel Ves No Mains connection 1 Connected Yes No 2 way directional valve installed correctly Yes No Volume in Cable cross section in mm Water circulation pump set Ves No Pump level Control type for high efficiency pumps only Hydraulic switch decoupling Yes No Hot water tank installed Yes No Type Mains connection 2 Connected Yes No Cable cross section in mm Volume in With solar integration Yes No 11 50 Aquarea air water heat pump Installation manual for compact systems 03 2013 Panasonic Appendix 5 Commissioning report ideas for life Panasonic ideas for life Commissioning report Electrical connections Mains connection 3 connected Ves No Cable cross section in m
7. Side view Y os 3 Rear view 4 Top view Dimensions of compact unit with one fan in mm The air flow is indicated by arrows 3 2 2 Compact unit with a nominal output of 9 to 16kW 1 283 Be A A Panasonic oO O st e s Y Y 3 i ME um B 1 Front view gt ZZ S09 a Ze 8 F 3 Side view Y 3 Rear view 150 980 150 4 gt lt 4 Top view Dimensions of compact unit with two fans in mm The air flow is indicated by arrows Aquarea air water heat pump Installation manual for compact systems 03 2013 3 11 Oo gt gt E o gt e Device overview Panasonic Accessories ideas for life 3 3 Accessories No Component Included Quantity Comments Add on circuit board for solar thermal connection compact systems Add on circuit board for solar thermal connection CZ NS2P Add on circuit board for solar thermal connection mini compact systems Add on circuit board for solar thermal connection CZ NS2P Hot water tank WH TD20B3E5 200 litres WH TD20B3E5 300 litres Hot wa
8. a maximum of 3 bar Aquarea heat pumps may only be installed as sealed systems without direct contact of the heating water to the ambient air o oe SS E o 53 gt rs The compact units feature an expansion tank as standard approx 10 litres of air capacity initial pressure of 1 bar By contrast the mini compact units WH MDFO6E3E5 and WH MDFO9E3E5 with heating capacities of 6 and 9kW have an expansion tank with only 6 litres of volume Accordingly these devices can only be used for heating systems with a total water quantity in the system of under 150 litres See the design handbook for split systems and compact systems for connection variants Aquarea air water heat pump Installation manual for compact systems 03 2013 6 17 Hydraulic installation Panasonic a m HL OL ll a 254737959 TAr uno cae BU e B VS uu Mw Nee gg B ur Description of the functions of the sample hydraulic installation with water heating and heating The hot water tank is supplied with heat as an alternative to the heating circuits For this purpose the heat pump controller opens the three way directional valve towards the hot water tank Then the hot water tank is charged to the target temperature with appropriate supply temperature In heating mode the heat pump controller opens the three way directional valve towards the heating circuits and supplies them with heat The supply temperature is controlled based o
9. delivery Connection 1 pin min 3mm contact clearance When the contacts are open the device is switched off and the remote control is disabled The jumper between terminal 17 and 18 must be removed if the external control device optional is connected to the hydro module The max operating current of the control device must be less than 3 Ans Ext control sig Input for external control sig 17 to 18 nal nal Temperature Input for temperature sensor Use an NTC sensor sensor for hot of the hot water tank water tank Temperature Input for temperature limit Terminals 13 14 must be jumpered if no temperature limit switch for switch of the hot water tank limit switch is used for the hot water tank hot water tank For exclusive control of heating mode via the external room thermo stat only phases L and L1 are con nected to the terminal strip This also applies for devices without a cooling function This connections do not permit switching between heating and cooling mode Room Input for external room thermostat thermostat Condition L L1 Room temperature gt Circuit open Circuit closed Target temperature heating off cooling on Room temperature lt Circuit closed Circuit open Target temperature heating on cooling off Operating mode Heating Cooling heat pump Electric immer 230V output for activating The maximum output capacity of the electric immer sion heater for deactivating the electri
10. heat pump See also the instructions in the design handbook Note As standard the high efficiency pump is preset to control type A p c level 4 Panasonic recommends control type A p c p c constant differential pressure The high efficiency pumps in Aquarea heat pumps have two control types which can be set on the pump A p c constant differential pressure The electronic system holds the differential pressure target to be maintained by the pump at the value set level 1 to 7 as per the curve below p v variable differential pressure The electronic system changes the differential pressure target to be maintained by the pump configurable between levels 2 to 6 whereby the differential pressure decreases simultaneously with the volume flow to max half of the differential pressure target oet the pump level of the high efficiency pump by turning the red adjusting knob to ensure that the minimum volume flow is present 50 40 30 20 m Co A ioo Pump operating head kPa 0 10 20 30 Flow rate l min 8 1 3 Handover and instruction Pump operating head kPa 40 50 0 10 20 30 40 50 Flow rate l min Pump characteristic curve of the high efficiency water circulation pump for the Aquarea Mini compact devices WH MDFOGESE5 and WH MDFO9ESE5 Complete the commissioning report see Appendix Check again that all installation work ha
11. or systems and compact systems neighbours contains further information on The compact unit sound output direction should face the street side if soundproofing possible as neighbouring rooms which require protection seldom face in this direction 4 14 Aquarea air water heat pump Installation manual for compact systems 03 2013 Location Installing the device Panasonic bd ideas for life 4 2 Installation Danger At least four persons are required for installation work Otherwise the weight of the device can lead to injuries Transport and lifting equipment must be suitable for the device weight If possible the device should only be moved with the appropriate trans port and lifting equipment The lifting equipment can be attached to the base structure of the device using lugs Transport the device to the planned installation location I Remove the packaging carefully Fasten the device with four M12 anchor bolts tightening force 15 000 N e 2E Ow 8S 7 GE Transport the device carefully to avoid damage That includes placing lowering the device in the installation location 4 gt 60 mm 1 Floor 2 MT 4 1 2 Stone gravel 5 77 77 77 i 3 Concrete or floor plate AV Ay ULL 2 ogm 4 Anchor bolt YY gt 20mm Minimum requirements for anchoring the compact unit to the floor or a foundation left or directly to a base p
12. the CANCEL button Activating the timer Press the TIMER button then the SET button Checking the timer program Press the TIMER button Press the UP or DOWN button until the required weekday is displayed Press the SELECT button to confirm the setting Press the UP or DOWN buttons to check the programs set Deleting timer programs Press the TIMER button Press the UP or DOWN button until the required weekday is displayed Press the SELECT button to access the program setting Press the UP or DOWN button until the required weekday is displayed Press the CANCEL button to delete the program setting CO 2 E E o O Aquarea air water heat pump Installation manual for compact systems 03 2013 8 45 Maintenance Checking the water pressure Checking the pressure relief valve Panasonic 9 Maintenance A Danger The maintenance work may only be performed by qualified or certified personnel The device carries potentially fatal voltage when open En sure that you have disconnect ed the power supply if the maintenance steps require this before you perform mainte nance work E ide Fy Ee ffs ga i igadeas TOr Open the compact unit as described in Section 5 The following maintenance steps must be performed annually Check water pressure Check pressure relief valve Visual inspection of circuit board Clean dirt trap Check R
13. 2to 16kW 9to16kW If the temperature limit switch was triggered at a high water tempera ture perform the following steps to reset it Remove the cover Heset the temperature limit switch by pressing the middle button gently with a test pen Resetting the temperature limit switch 9 48 Aquarea air water heat pump Installation manual for compact systems 03 2013 Panasonic Recycling ideas for life 9 7 Venting the system Checking the quick vent 1 Quick vent Tm T Turn the valve cap on the quick vent one full turn counter clockwise and allow any air in the heating system to escape until fluid flows out Repeat the process until you can no longer hear air bubbles moving Close the quick vent again by turning it clockwise 1 Quick vent 2 Valve cap 10 Recycling After the end of the product s service life it must be disposed of appro priately When disposing of the packaging the device or individual com ponents please observe the local recycling regulations The respective environmental protection regulations must be observed O c o gt o s tc Aquarea air water heat pump Installation manual for compact systems 03 2013 10 49 Appendix Panasonic Commissioning report ideas for life
14. 3 YVes No Water supply target temperature in cooling mode Heater cap The parameters Fun to oPr are only for configuring sterilisation 11 52 Aquarea air water heat pump Installation manual for compact systems 03 2013 Panasonic Appendix 5 Commissioning report ideas for life Commissioning report Panasonic ideas for life Measurement report in heating mode after 20 min runtime Evaporation pressure Machine voltage in bar in V Evaporation temperature in V ne in V ouction gas temperature Compressor current consumption nee inA T Overheating in A L2 in K in A L3 Additional electric heater for heat pump current consumption in A L1 Condensing temperature in A L2 in C in A L3 Condensing pressure in bar Electric immersion heater for hot water tank current consumption in A L1 Compressor end temperature RCD test in C Mains connection 1 OK l Yes No Outside temperature Mains connection 2 OK Ves No in C Mains connection 3 OK Yes No Liquid temperature in C Evaporator air intake temperature Tank temperature in C in C Evaporator air outlet temperature Pressure drop in hydraulic system in C in bar Condenser water inlet temperature High pressure switch triggers Yes No in C owitch off point in bar Condenser water outlet temperature Switch on point in bar in C Low pressure switch triggers Yes No Switch off point in bar owitch on po
15. CC GN i re T T TT 49 IN iJ4 50 Commissioning report 2 0 e me e e e ee e eee eee e ais 50 Handover report RE tena 55 Acceptance Certificate 000 b bebe e eese 56 Ol COGCS MEMMT 57 1 4 Aquarea air water heat pump Installation manual for compact systems 03 2013 Panasonic As F 5 ay eas for life 1 Introduction 1 1 About this manual 1 2 Target audience 1 3 Products covered Introduction About this manual Target audience Products covered i Ew 5 gt xe Oo E rm This manual provides you with information on simple and correct mount ing as well as hydraulic and electric installation Ensure that you have read and understood the installation and safety in structions in this manual before you start work Incorrect installation due to a failure to follow instructions in this manual or insufficient compliance with the instructions can result in damage If you are unsure about the installation please contact our service team for clarification 01344 853182 This manual is intended for qualified installation engineers and electri cians It is not intended for unqualified persons Electrical and plumbing installation work must be performed by a quali fied electrician or plumber T
16. CD e Check the quick vent 9 1 Checking the water pressure Check the system pressure on the manometer If the system pressure is less than the target pressure add liquid 9 2 Checking the pressure relief valve 1 Fastening screws 2 Lever 3 Pressure relief valve 4 Raise lever Pressure relief valve Open the fastening screws as shown in the figure Check the function of the pressure relief valve by moving the lever of the pressure relief valve to the horizontal open position briefly Escaping air or liquid must be clearly audible If not contact an authorised dealer Return the lever of the pressure relief valve to the basic setting closed Aquarea air water heat pump Installation manual for compact systems 03 2013 m Maintenance Panasonic Visual inspection of the circuit board Cleaning the dirt trap ideas for life 9 3 Visual inspection of the circuit board Visually inspect the circuit board for loose connections damaged cable insulation etc 9 4 Cleaning the dirt trap 1 Water outlet WATER OUT Dirt trap Water inlet WATER IN Union nut Connection o a A CO N Shutoff valve Position of the dirt trap A Warning Where applicable close the shutoff valves upstream and downstream Do not damage the mesh of the dirt trap of the dirt trap Use a spanner to open the dirt trap Remove the insert ensuring not to damage the mesh of the ins
17. EEEE EEEE EEEE EEEE orud ad EEEE 23 7 2 Inputs and outputs external interfaces uLuLu tttusssssssssssssssee 26 7 3 Installing the wired remote control 2a precor idest ndn ak testata eo wd aber VP EP EPAUU iab cEERE 29 7 3 1 Laying concealed cables eciadde odisse otn oT crant EELEE EEEE EEEE PME EDDA 31 7 3 2 Laying VISIDICCADICS 2 cosomeseuvvSrtucdeuidmptrdxheddibdd M HERI PEtuIeRI NU CERE Pendqa d 32 7 3 3 Connection to the compact unit sssssssssssssssssss eee 33 8 COMMISSIONING 2 2 Ie e e e e e esas e e beeen ees 34 8 1 Commissioning oso t soe cecconme re 34 8 1 1 Setting the standard pump 00 occ cect Ie 35 8 1 2 Setting the high efficiency pump 2 ccc n nbn eee e eens 36 8 1 3 Handover and instruction i224 ccninmaccdacascemoratacachnmentietas nansseppaasasege MM REEUPQEM 36 o ierit 37 9 Maintenance 00 nee 46 9 1 Checking the water pressure 2 IRR eene 46 9 2 Checking the pressure relief valve ssssssssssssssssssssssRRRRRRRRRRRe 46 9 3 Visual inspection of the circuit board 0 cece Re 47 9 4 Cleaning the dirt trap ccc ccacccossinszdgcosenuursadanentdes o pasta Urge bPloi Von rav EPERarE e bebo pee DOS 47 9 5 Checking the RCD II e e ee ee e e e sanis 48 9 6 Resetting the temperature limit switch 2 2 00 cent bene eee nnn eens 48 9 7 Venting the system Checking the quick vent 0 eee eens 49 10
18. ET HEATER SEARCH w SELE yp ERROR RESET FORCE SERVICE C Set the temperature values as follows Press the SET button for 5 seconds to switch to Setting mode Press the UP or DOWN buttons to access the following 8 tempera ture parameters 8 38 Aquarea air water heat pump Installation manual for compact systems 03 2013 m Commissionin Panasonic Programming ideas for life Temperature values 1 Low outside temperature 4 Water supply target temperature 7 Water supply target temperature in 15 to 15 C Std O C for heating mode at high outside cooling mode 5 to 20 C Std 16 C temperature 25 to 55 C Std 32 C Sa ej DEFROST Bann 2 High outside temperature 5 Target temperature for switching 8 Target temperature of the hot 15 to 15 C Std 15 C off heating mode limit heating tem water tank 40 to 75 C Std 55 C perature 5 to 35 C Std 24 C 3 Water supply target temperature 6 Outside temperature for switching for heating mode at low outside tem on the additional electric heater perature 25 to 55 C Std 55 C 15 to 20 C Std 0 C Note Press the SELECT button to select the parameter No target temperatures san be entered tor thewater Use the UP or DOWN button to set the required temperature supply temperature in cooling mode on the operator control panel of the SDF versions Press the CANCEL but
19. ON P E gy DEFROST HEATER f Lm Can pa m STATUS FORCE C m SERVICE OPERATION WATER OUTLET OFF ON I et P SETTING STATUS MODE CHECK MODE A c QUIET HEATER SEARCH Oo y ERROR RESET DS Set the operating mode as follows Press the MODE button The operating mode changes as follows every time the button is pressed SDF model Heat Heat Tank Tank SDC model Heat Heat Tank Tank Cool Tank Cool Aquarea air water heat pump Installation manual for compact systems 03 2013 in C m m m Panasonic ommissioning Programming ideas for life Special functions Setting special functions A Danger During sterilisation do not re TIMER OUTDOOR ACTUAL HEAT E wn 4e al El move hot water as this can coo lw aie sk Sh BBB s ur ps cs gg Ap C gm DEFROST H UIET lead to burns or overheating p WA A p00 ij ais ope FORCE SERVICE The sterilisation function set OPERAN WETERDUTIET OFF ON 1 tings must be made by an au thorised dealer in accordance with the local laws and guide ned T lines ERR OR RESET e UG MODE Switch the device off using the OFF ON button before setting special functions operation LED does not light up Display on operator Description control panel External room thermostat YES NO Standard NO Setting whether an external room thermostat is connected Select the required output of the ad
20. Order Nr A2W SPX 130305 021 Panasonic Aquarea Air Water Heat Pump Heating and Cooling Systems INSTALLATION MANUAL for Compact Systems Service For any questions on Commissioning Malfunctions Technical support our hotline is available around the clock at 01344 853182 Nationwide service organisation 24 7 emergency service Commissioning Maintenance Professional service processing If required cooling system installation support Central spare part supply Central call centre number for Commissioning Malfunctions Technical support Panasonic Table of contents 1 Gel nnEr 5 Ted 33DODE IIS MANUEL eae s tavated E i yes trn eS ORE EA E EE AE SER RN sagen 5 1 2 Target audience oon e s ee rere 5 1 3 Products covered E 5 t4 SyMDO USE a ee AAE PIE NIRE 6 1 5 Tools required 220 oon EEEE EEEE e eme ees 6 1 6 To be provided by customer cuuoecabvtis hentrpttet EL p vate Soc Tro derpEUbEe ase tatus rabie dose Pad emt 6 1 7 Installation sequence sstttututttttuttsssssssssss IIR e eee lees T7 A OEN INSWUIGHONS d 8 2 1 General hazard instructions for avoiding electric shocks L uso 8 2 2 General hazard instructions to avoid damage to
21. Setting the weekly timer Panasonic ideas for life OUTDOOR ACTUAL vw B HEATER D UU m Booster OE m pu ui x uH 4 C gy DEFROST x 8 s SETG C g SERVICE WATER OUTLET SETTING STATUS SETTING d DY ERROR RESET FORCE SERVICE o Open the timer by pressing the TIMER button Set the date and time Press the UP or DOWN button until the required weekday is displayed Press the SELECT button to confirm the setting 1 flashes on the display Press the SELECT button to set Program 1 Press the OFF ON button to select the activation deactivation timer Use the UP or DOWN buttons to set the required time In addition to the switching time you can also set other modes using the MODE or QUIET buttons Press the SET button to confirm Program 1 The weekday selected is identified with the W symbol After 2 seconds the display switches to the next program Repeat the above steps starting with the OFF ON button to set programs 2 to 6 If no buttons are pressed for 30 seconds during timer setting or if you press the SET button the current setting is saved and the setting process is closed Aquarea air water heat pump Installation manual for compact systems 03 2013 Commissioning Panasonic Programming ideas for life Setting the weekly timer Changing or adding timer programs Repeat the above mentioned steps Deactivating the timer Press the TIMER button then
22. and hold the ERROR RESET 8 seconds until you hear a beep Reading the last error code stored in the EEPROM Press the CHECK button for 5 seconds to access Status mode Press the SEARCH UP or DOWN button to see the last error code Press the CANCEL button or wait 30 seconds to exit STATUS mode Deleting the last error code stored in the EEPROM Press and hold the ERROR RESET gt 8 seconds until you hear a beep Aquarea air water heat pump Installation manual for compact systems 03 2013 N N NNY j NY NW iN Y WV P11 WN 9Iuoseueg JO UONeSOUINE ssaJdxa y INOYUM paliqiyod si anoe siu jo uoronpoudai erued JO e30 au 1onpoJd y eAoJduil 0 oud nou Jaunjoejnuew y q suoneoiipoui JOUIWW 0 39e qns aq Aew pue sJ0418 DIYydesHodA Gurueq pi eA ae anoe siy Jo suoneoyioeds ay sjonposd WI eAOuU BuloGug aim 61 sng g O 0 us gt O gt im O u o im i 9 O o it c c am gt O E en dud oO ce c p O www panasonic eu log on to Contact Details Telephone 01344 853182 www panasonic co uk Address Panasonic Air Conditioning Panasonic House Willoughby Road Bracknell Berkshire RG12 8FP
23. ater unit in the compact unit prevents the heating damage to the device circuit freezing The heating circuit is operated with a food safe antifreeze mixture 40 propylene glycol mixture for temperatures down to 20 C he heating circuit is drained by a system to be provided by the customer manual or automatic A Warning Fill the system as follows To prevent damage to the heat pump from lime scale please consult BS 7593 Code of practice for treatment of water Connect a filling hose evacuated if possible to the system in domestic hot water central heating systems Open all thermostatic radiator valves of the heating system and all other shutoff valves where applicable ery CE 1 Manometer Keep adding water or antifreeze mix until the manometer reaches the nominal pressure Vent the system see the Commissioning section Then check the pressure again and add liquid if necessary 6 20 Aquarea air water heat pump Installation manual for compact systems 03 2013 ri Hydraulic installation Panasonic ideas for life
24. c im sion heater for hot water storage tanks should not hot water tank mersion heater for hot water exceed 3kW storage tanks 230 V output for control of the s il m Hot water tank n pale POILSSHOR dM 3 way directional valve e g A m cosa 0 S valv Sue for heating hot water tank sW Heating circuit OPEN AB gt B Connection on automatic deactivation 9 of heating circuits in cooling mode BEEN via a 2 way directional valve MM CLOSE Top Motorised 2 way directional valve Bottom Spring loaded 2 way directional valve normally open 230 V output for controlling the 2 way directional valve e g for floor heating cooling 2 way directional valve Terminal strip and table of inputs and outputs with functions Aquarea air water heat pump Installation manual for compact systems 03 2013 7 2T7 m O d O 2 LLI ce ex o Electrical installation Inputs and outputs external interfaces Panasonic ideas for life 1 Terminal strip 2 Cable ties 3 Cable gland Cable gland N Chamber front panel oO Power supply 3 core or 5 core for three phase 400 V compact units 4 Cable for 3 way directional valve 3 core 5 Cable for 2 way directional valve 3 core 6 Optional cable Note The outside temperature sensor is in the compact unit and does not have to be installed or con nected as the measurements are t
25. c installation Danger The work can only be performed by qualified or certified personnel Follow these instructions to prevent damage to the compact unit and the other components of the system Flush the pipelines before connecting the device to remove impurities Impurities can damage the components of the device Ensure that the components installed in the wet circuit can withstand high operating water pressures Use only suitable sealants which can withstand the pressure and temperature of the system Never use worn pipes Do not use a pipe wrench to mount the connections Use two adjustable wrenches to tighten the connection Warning There must be at least 50 litres for 12 0 to 16 0kW devices or 30 litres for 6 to 9 0kW devices of liquid in the system If these values are not reached an additional storage tank must be installed The standard expansion tank can be used for heating systems with a to tal water quantity in the system of less than 200 litres without a hot water tank and a static system height of no more than 7 metres difference of the highest point of the system to the expansion tank If the total water quantity is greater than 200 litres or greater static heights are required pressure retention must be ensured via an expan sion tank to be installed by the customer In general the pressure level of the pressure relief valve must be observed See the technical details for the pressure level to
26. connection 2 Mains connection 3 m O os O qm S oD TT Electrical installation Inputs and outputs external interfaces 7 2 Inputs and outputs external interfaces IP 2 Y AST 4 Zz a 2 i gn Mmmm 7 gt yee EN 3 anc mn Panasonic ideas for life Ext control signal 3 33 Temperature sensor for hot water tank Temperature limit switch for hot water tank 2223333J Room thermostat y nin y Electric immersion heater for hot water tank 2 4 I d 3 way directional valve yyy M 2 way directional valve 00 5 DDDD O OO Aquarea air water heat pump Installation manual for compact systems 03 2013 Electrical installation Panasonic Inputs and outputs external interfaces ideas for life Comments Terminals Connection Function Use additional circuit board CZ NS1P CZ NS2P or CZ NS3P Solar pump Input of the ON signal gt Connect the 3 way directional valve Output for triggering so that it prevents flow through the Solar 3 way acti solar circuit and heat exchanger of d directional valve the solar 3 way directional g nn valve the hot water tank when closed These two terminals are jumpered on
27. ctive Press the ON OFF button to switch off emergency heating mode p E E o O 23 Error reset button 24 Quiet mode button 25 System programming buttons These buttons are used to set temperature values 26 Timer programming buttons These buttons are used to set the time and the weekly timer Aquarea air water heat pump Installation manual for compact systems 03 2013 Commissioning Panasonic Programming ideas for life Weekday and time Temperature values Setting the weekday and time Note The current weekday and time OUTDOOR AGUA must be set when p MEE SHAR 8 sos mo 0p a ane the power supply is switched Ws i Tux 00 STATUS a i 2i C m SERVICE on for the first time WATER OUTLET OFF ON 1 along interruption to the e umm SETTING STATUS SETTING ower SU i MODE CHECK TIMER P d 5S S The current time set is the time CPU ERROR basis for all timer functions RESET xe CLOCK oet the weekday and time as follows Press the CLOCK button Press the UP or DOWN button to set the current weekday Press the SET button to confirm the setting Repeat steps 2 and 3 to enter the current time Setting the temperature values OUTDOOR ACTUAL Ms B uu X DU m raa t WB cs 4 DEFROST E FF kai db SETTING E AN Ta FHH E STATUS SERVICE WATER OUTLET OFF ON 1 et SETTING STATUS SETTING MODE CHECK A SET A QUI
28. deas for life Acceptance certificate Company name Panasonic ideas for life MN Machine type Buyer Invoice address We commissioned the above mentioned system today instructed the operating staff owner and handed over the documentation The system is free of faults and the warranty starts on today s date Comments Place Date Customer signature Contractor signature 11 56 Aquarea air water heat pump Installation manual for compact systems 03 2013 Panasonic Appendix 5 Error codes ideas for life Error codes Error code Error Protection triggered Error recording Faz Pressure swin viagere atimas ihn 20minutes Faa incorect compressorspee anmeswihin 20mnues Fis ircorect sneed ofthe oudooruntfan Twice wiin ao minutes Fie Protection against excessive otal operating curen 3 times wihin 20 minutos F20 compressor overeating quad atmeswihin 90 mnues F Poner ansisormedue ovehestng guard B imes wiin 20 mutes Fas Drect curent peaks inthe outdooru OcumedT mes Fas Protem switching between heating and cooing 4times win so minutos F27 Fe ousie temperature sensor e seconasong z Fao horgas temperature sensor nthe outdoor unt 6 secondsong FM Poom O O O mesos Faz Temperature sensor ofthe heat exchanger in We outdoor unit 8 secondslong Fas Outdoor unt dosing temperature sensor 6 secondsong Fas surly temperature sensorinindoor nt 6 secondsong Fa Curenconere
29. ditional electric heater 3 6 or 9kW Standard Maximum The output of the additional electric heater can be reduced if higher power is not needed This will depend on model selected Water antifreeze function YES NO Standard YES Activation or deactivation of the antifreeze function when the device is switched off Connection of a hot water tank YES NO Standard NO Setting whether a hot water tank is connected Note If Hot water tank connected is set to NO steps 5 to 14 are skipped soar Pry Ex priority YES NO Standard NO soan Pey Soar the priority of the solar installation for water heating Heating priority YES NO Standard NO Setting the heating as a priority over hot water Note If Heating priority is set to YES steps 7 to 8 are skipped Duration of heating period Setting the duration of heating mode in the heating and water operating mode 30 min to 10 hours Standard 3 hours Water heating duration Setting the duration for water heating in the heating and water heating operating mode 5 min to 1 hour 35 min Standard 30 min CO Hot water immersion heating function YES NO Standard YES Activation or deactivation of hot water immersion heater Note If the Hot water immersion heating function is set to NO step 10 is skipped These menu items are only displayed Commis if TANK is set to YES Only displayed if HEAT PRIORITY is set to NO Switch on delay of the electric immersio
30. e upper cover to the lower cover of the remote control using the clamps provided Aquarea air water heat pump Installation manual for compact systems 03 2013 7 31 Electrical installation Installing the wired remote control Laying visible cables 7 3 2 Laying visible cables Remote control cable Upper clamp Upper cover Plug connector CON1 Lower cover Screw VN O OC A Q N Lower clamp Cable outlet to the top Lower cover Tabs Remote control cable a A Q N Notches A Danger Lay the cable as shown in the figure above so that the housing of the remote control can be closed securely Panasonic ideas for life Use the two supplied M4 x 14 screws to secure the lower cover of the remote control to the wall When tightening the screws ensure that the screw heads not sitting proud Use only the supplied screws Select an outlet direction of your choice for the remote control cable and use a wire cutter to open one of the notches provided for this pur pose in the upper cover in accordance with the outlet direction Route the remote control cable in the lower cover as shown in the figure based on the outlet direction selected Fasten the connection of the remote control cable to the plug connector CON1 in the upper cover of the circuit board Ensure that is securely attached Secure the cover to the lower cover of the remote control using the clamps provided Aquarea a
31. electric heater for hot water tank for heat pump 3 Strain relief for heat pump and 3 Strain relief Mains connection for compact unit Mains connection for compact unit 12 to 16 kW three phase 12 to 16 kW single phase Tu Us Tu Uu 7 1 2 3 POWER SUPPLY 3 POWER SUPPLY 1 G Le O qm S oD TT oY 263 5 d s EFE Ea LTO EN LIE PL LN Pus Ns Power supply 1 Power supply 3 Power supply 2 Power supply 1 Power supply 2 Power supply 3 1 Compact unit 3 Electric immersion heater 1 Compact unit 3 Additional electric heater 2 Additional electric heater for hot water tank 2 Electric immersion heater for heat pump for heat pump 4 Strain relief for hot water tank 4 Strain relief Aquarea air water heat pump Installation manual for compact systems 03 2013 7 23 Electrical installation E Mains connections Panasonic J i 4 E em T e yp I a IO pe ley ez BH We Han Open the compact unit as described in Section 5 Use cables compliant with 60245 IEC 57 or thicker for the mains connections 1 Ma
32. ert Rinse the insert with tap water Use a soft brush to remove stubborn dirt Replace the insert in the dirt trap and seal the dirt trap with the spanner If applicable open the shutoff valves Aquarea air water heat pump Installation manual for compact systems 03 2013 9 47 Maintenance Panasonic Checking the RCD Resetting the temperature limit switch r lif or ine 9 5 Checking the RCD A Danger If applicable set the RCD to ON The device carries potentially fatal voltage Ensure that you owitch on the power supply of the compact unit do not touch any live device Press the TEST button on the RCD The lever must move down to parts Only touch the buttons the OFF green position if the RCD works properly If not contact of the RCD an authorised dealer owitch off the power supply of the compact unit Set the lever of the RCD back to ON 9 6 Resetting the temperature limit switch o L 9 l o S rs S S f 8 i el KG Lec Lec EN 1 Temperature limit switch Single Single Three differs from model to model phase phase phase see Detail A 9 kW 1
33. for increasing the total water volume to be used when the total volume is lower than the minimum volume 1 Cold water connection 3 Outside temperature sensor 4 Heating circuit mixer closed loop control 2 Room thermostat integrated in outdoor unit to be provided by customer 5 Hot water tank WH TD20B3E5 Sample hydraulic installation with water heating and heating system see Aquarea design handbook for other examples Thermostatic radiator valve 3 way directional valve N Single room controller valve 3 way mixer 3X Overflow valve Drain funnel ds Water tapping point Pump Non return valve Manometer Dirt trap Pressure relief valve Temperature sensor Pressure reducing valve n Storage tank 0 for minimum volume Control wire 6 18 Aquarea air water heat pump Installation manual for compact systems 03 2013 ri Hydraulic installation Panasonic uj m ES mt e ae T T o a hE Pen icas IJI Cr Ile Open the compact unit as described in Section 5 Install the pipes valves dirt trap and other components in accord ance with the design documents 1 Water supply WATER OUT Dirt trap Water return WATER IN Union nut Connection o a A CO N Shutoff valve Position of the dirt trap A Warning Install a dir
34. g Observe the minimum clearances as shown in the following diagram Component Quantity Comment Hemote control cable 15m long Screw MA x30 mm 3 For installing the remote control on an machine screw outlet embedded connection cable Screw MA x 14 mm 3 Installing the remote control on the self tapping screw wall exterior connection cable Included accessories m c Le O qm S oD TT Aquarea air water heat pump Installation manual for compact systems 03 2013 7 29 Electrical installation Panasonic Installing the wired remote control ideas for life 1 Upper cover 2 Lower cover 3 3 Clearance 30mm 4 Clearance 120mm 3 3 A lt Minimum clearances to be observed for the wired remote control If necessary open the compact unit as described in Section 5 1 Upper cover 2 Lower cover ure i 3 Screw M4 x30 S or M4x14 Opening the wired remote control Remove the lower cover of the wired remote control by placing a flat head screwdriver or similar tool in the lower slots and carefully lever ing the upper and lower covers apart Ensure that you don t damage the housing Remove the lower cover Ensure that the protective tape between the circuit board and the upper cover is not removed 7 30 Aquarea air water heat pump Installation manual for compact systems 03 2013 Panasonic Electrical installation 5 Installing the wired remote control ideas for life Layin
35. g concealed cables You can lay the wired remote control cable so that it is concealed or visible 7 3 1 Laying concealed cables Laying concealed cables Upper cover Upper clamp Plug connector CON1 Lower cover Screw Lower clamp Flush mounted box ce N O OA A CQ N Remote control cable Laying cables in the wired remote Upper cover Ond Cable outlet to the rear Lower cover Tabs Upper cover Cable connection CON1 oO c A Q N m A Danger Insert a flush mounted box to be provided by the customer into the Lay the cable as shown in wall medium sized rectangular socket Panasonic part no DS3744 the figure above so that the or similar housing of the wired remote Insert the wired remote control cable into the socket control can be closed securely G Ss O qm S o D TT Route the concealed wired remote control cable to the wired remote control as shown in the figure Warning Use the two supplied M4 x30 screws to fasten the lower cover of the remote control to the flush mounted SOCket Ensure that the lower cover is not under strain and do not tighten the screws excessively Use only the supplied screws In cavity walls use a bushing for the wired remote control cable to prevent rodents biting the wire Fasten the connection of the remote control cable to the plug connector CON1 in the upper cover of the circuit board Ensure that is securely attached Secure th
36. he following hazard instructions If you fail to do so there is a risk of fatal injury or damage to health The refrigerant can cause freezing if it comes in contact with skin Only use the refrigerant specified The refrigerant may not be mixed with other types of refrigerant or replaced with other types of refrigerant Using other refrigerants can damage the device and result in safety problems The manufacturer accepts no responsibility or warranty if refrigerants of types other than R410A are used for the Aquarea LT series and T CAP or R407C for the Aquarea HT series 2 8 Aquarea air water heat pump Installation manual for compact systems 03 2013 Panas nic Safety instructions Hazard instructions for avoiding material damage Information 3 5 dme ideas for li Only use the device in sealed systems Use in an open vented system can result in excessive corrosion of the water pipes and increase the risk of bacteria colonies forming in the water legionella in particular N Do not install the device in locations where leaks of flammable gases can occur Otherwise there is a risk of fire or explosions o c ce Ss 3 A m S 2 3 General hazard instructions for avoiding material damage Warning Observe and comply with the following instructions If you do not there is a risk of material damage e g via vibration water leaks or fire
37. health 000s 8 2 3 General hazard instructions for avoiding material damage ccc cece ees 9 2 4 General further information 0 000 0000 RR nene 9 3 Device overview L auauua anaku eaae AAEE EEEE EEEE EEEE EEEE e emen eme ee een 10 3 1 Components nuana aeaaeae EEE EEEE EEEE EEEE EEEE ss sss RR Renee anus 10 o Dimensions diaglaM 25 eessrensere seuna E EN EEEE a REE E EE 11 3 2 1 Mini compact unit with a nominal output of 6 to 9KW aaaea ananena 11 3 2 2 Compact unit with a nominal output of 9 to 16 kW LLLLLtttt ttttiusssssssese 11 3 3 Accessories 220 ee e ese hse e EE Eee End n enar reris 12 4 Location Installing the device L LLL LLLL osssssssRR ee 13 A MOCANOM NETT IT TT M nMnnmn 13 4 2 uci M 15 5 Opening the device aonana nqsaien tir Eo Per T Rh ApEaYRPRDIIPIEUE anmeddande sgsbib ders MUERE DE ed 16 6 Hydraulic installation sss ee 17 Aquarea air water heat pump Installation manual for compact systems 03 2013 Panasonic ideas for life 7 Electrical installation aaaea aaaea EAEE EEEE EEEE EEEE EEEE EEE EEEE EEEE EEEE EEE 22 7 1 Mains connections x icszenasonan dURdRIRP3dadePisdOP ag CE tevsiie aa TOPROI d EEEE
38. his manual covers the following Aquarea heat pump systems Aquarea LT WH MDFOGESES5 WH MDFO9ESES WH MDFOSCS3ES5 WH MDCO9C3E5 WH MDFO9C3E8 WH MDCO9C3E8 WH MDF12C6E5 WH MDC12C6E5 WH MDF12C9E8 WH MDC12C9E8 WH MDF14C6E5 WH MDC14C6E5 WH MDF14C9E8 WH MDC14C9E8 WH MDF16C6E5 WH MDC16C6E5 WH MDF16C9E8 WH MDC16C9E8 Aquarea T CAP WH MXFO9D3E5 WH MXCO9DSE5 WH MXFO9D3E8 WH MXCO9D3E8 WH MXF12D6E5 WH MXC12D6E5 WH MXF12D9E8 WH MXC12D9E8 Aquarea HT WH MHFO9D3E5 WH MHFO9DSE8 WH MHF12D6E5 WH MHF12D9E8 Devices have a high efficiency pump and fulfill the criteria of the Ecodesign Directive valid from 2015 for energy related products ErP Aquarea air water heat pump Installation manual for compact systems 03 2013 1 5 Introduction Symbols used Tools required 1 4 Symbols used Danger Danger Warning NOTE 1 5 Tools required 1 6 To be provided by customer Panasonic The warnings in this manual absolutely must be heeded as they are safety critical The symbols have the following meanings Danger of fatal injury from electric shock if not observed Danger of fatal injury or damage to health if not observed Material damage if not observed Further information Identification of a step We recommend that you use the following tools Phillips head screwdriver Tape measure Spirit level Multimeter Electric drill Torque wrench 39 2 Nm Set of spanners Torq
39. ideas for life Indication Devices with high efficiency pumps are identified separately in the overview on page 5 8 1 1 Setting the standard pump Pump level 3 Pump level 2 Pump level 1 A Warning Ensure that the minimum flow rate does not fall below 191 min or 101 min for Aquarea Mini compact devices Aquarea air water heat pump Installation manual for compact systems 03 2013 Commissioning Commissioning Setting the standard pump Return the lever of the pressure relief valve to the basic setting closed after a few seconds Repeat the process until you can no longer hear air bubbles moving Check the system pressure on the manometer In normal opera tion the system pressure should be between 0 5 bar and 3 bar If necessary set the target pressure Check the cooling circuit in the compact unit for leaks Any leaks must be repaired Perform a test run to ensure that no malfunctions occur after installa tion Proceed as follows to do so Switch the RCD to ON Switch on the compact unit OFF ON button on the operator control panel or wired remote control See the next section for operation and programming Check the system pressure on the manometer again In normal operation the system pressure should be between 0 5 bar and 3 bar If necessary set the target pressure Set the water circulation pump Please note that settings differ for
40. ins connections 2 Cable ties 3 Cable gland Laying the cables inside the device Cut into the cable gland in a cross shape using a knife Route the cables through the enclosed cable gland on the right side of the housing to prevent the cables being damaged by sharp edges Connect the mains connection cable as shown in the diagrams Ensure that the earthing cable is slightly longer than the other cables Use the strain reliefs to secure the mains connection cables Connect the other end of the mains connection cable to the fuses 7 24 Aquarea air water heat pump Installation manual for compact systems 03 2013 Panasonic ideas for life BIA eM ats T WH MDCO9C3E8 WH MXCO9DS3E8 WH MHFO9D3E8 WH MDC12C9E8 WH MDC16C9E8 WH MDF14C9E8 WH MXC12D9E8 WH MHF12D9E8 WH MDFOGESES WH MDFO9CSE5 WH MXCO9DSE5 WH MXC12D6E5 WH MHFO9DS3E5 WH MDC12C6E5 WH MDC16C6E5 WH MDF14C6E5 WH MHF12D6E5 Electrical installation Mains connections Use the following fuses to protect the individual mains connections isolating distance between the pins at least 3 0 mm each WH MDFO9CS3E8 WH MXFO9DS3E8 WH MDC14C9E8 WH MDF12C9E8 WH MDF16C9E8 WH MXF12D9E8 WH MDCO9C3E5 WH MDFO9ESE5 WH MXFO9DSE5 WH MXF12D6E5 WH MDC14C6E5 WH MDF12C6E5 WH MDF16C6E5 Mains connection 1 Aquarea air water heat pump Installation manual for compact systems 03 2013 Fuse Mains
41. int in bar Flow rate cut out triggers YVes No Aquarea air water heat pump Installation manual for compact systems 03 2013 11 53 Appendix Panasonic ideas for life Commissioning report Panasonic ideas for life Commissioning report Measurement report in cooling mode after 20 min runtime Machine voltage in V in V Evaporation pressure in bar Evaporation temperature in C in V Suction gas temperature Compressor current consumption in C in A L1 in A L2 in A L3 Overheating in K Condensing pressure Faults found in bar Condensing temperature in C Liquid temperature in C Compressor end temperature in C Outside temperature in C Condenser air intake temperature in C Condenser air outlet temperature in C Evaporator water inlet temperature in C Evaporator water outlet temperature in C Customer signature Contractor signature 11 54 Aquarea air water heat pump Installation manual for compact systems 03 2013 Panasonic Appendix Handover report ideas for life Handover report Company name Panasonic ideas for life M Machine type Refrigerant Instruction completed with Confirmed by signature Buyer Invoice address Instruction completed with Signature Aquarea air water heat pump Installation manual for compact systems 03 2013 11 55 Appendix Panasonic Acceptance certificate i
42. ir water heat pump Installation manual for compact systems 03 2013 c Electrical installation Installing the wired remote control e Connection to the compact unit d Panason nS IU e Ui 7 3 3 Connection to the compact unit If necessary open the compact unit as described in Section 5 1 2 1 Remote control cable d z Jj E 2 CNREMOTE2 connection Ei Hd MN 3 Cable ties AB c m eo fo HE 4 Cable gland BC j al D oW Up i E 3 b 5 4 m i o l 1 Remote control cable 2 Chamber front panel m G Le O qm S oD TT Laying the cable into the device Cut into the cable gland in a cross shape using a knife Route the cables through the enclosed cable gland on the right side of the housing to prevent the cables being damaged by sharp edges Remove the dummy connection from the CN REMOTE2 connection Connect the wired remote control cable to the CN REMOTE2 connec tion Ensure it is attached securely oecure the cable using cable ties as shown in the figure Ensure that the cables cannot come into contact with hot device parts Aquarea air water heat pump Installation manual for compact systems 03 2013 Commissioning B m Commissioning a e im mau EN
43. it board 8 Front panel D Water return QR 14 view without upper cabinet panel 9 Upper cabinet panel B Water supply R 14 2 Pressure relief valve view without cover T Temperature limit switch 3 Flow rate cut out differs from model to model 4 Manometer 11 Additional electric heater 5 3 phase water recirculation pump joo esM Figure shows standard pump 12 Expansion tank 6 RCD differs from model to model 13 Cover 7 Cable gland 14 Quick vent Components of the compact unit with two fans 3 10 Aquarea air water heat pump Installation manual for compact systems 03 2013 7 Device overview Panasonic I Dimensions diagram Mini compact unit with nominal output from 6 to 9 kW ideas for life Compact unit with nominal output from 9 to 16 kW 3 2 Dimensions diagram 3 2 1 Mini compact unit with a nominal output of 6 to 9kW a 1 289 E 39 320 A oA Panasonic 1 E r B Q 1 8 SS ho Lo of Y pede CO E CN e Y Ty NP DR 110 le ra 83 5 135 n Lb 160 1 Front view LO o 4 e 4 185 2
44. late right MN Mg LO S B e Co Wr li L 980 a 1 280 5 Compact unit drilling template For installation locations which can be impacted by strong winds e g wind between buildings including building roofs the compact unit must be secured on site with additional anchoring to prevent it toppling over Protection against toppling over via anchoring Aquarea air water heat pump Installation manual for compact systems 03 2013 4 15 Opening the device P ana sonic ideas for life 5 Opening the device Danger The work may only be performed by qualified or certified personnel Ensure that the device is disconnected from the power supply before you perform the steps listed below Remove the front panel Remove the 5 fastening screws Push the front panel of the cabinet downwards to release the safety catches Pull the front panel forwards to remove it 1 Fastening screws Removing the upper cabinet panel Remove the 11 fastening screws Lift the upper cabinet panel from the device Reverse the steps accordingly to close the device 1 Fastening screws 5 16 Aquarea air water heat pump Installation manual for compact systems 03 2013 Hydraulic installation Panasonic ideas for life 6 Hydrauli
45. m status are shown Use the UP or DOWN buttons to toggle through the functions Press the SELECT button to access the settings for the respective function Press the UP or DOWN buttons to activate UP or deactivate DOWN the functions or to set the time and weekday Press the SET button to confirm the setting 1 Connection of a room thermostat 3 Water antifreeze function 5 Solar priority YES NO Standard YES NO Standard NO YES NO Standard YES NO If a solar thermal system is used this value should always be set to YES MATER OUTLET 2 Select the required output 4 Connection of a hot water tank 6 Heating priority YES NO of the additional electric heater YES NO Standard NO Standard NO If possible this value 3 6 or 9kW Standard Maximum should be left as NO as otherwise hot water is only heated with the electric immersion heater 8 42 Aquarea air water heat pump Installation manual for compact systems 03 2013 Panasonic ideas for life DEFROST 7 Duration of heating period 30 min to 10 hours Standard 3 hours Setting the duration for heating mode in the heating and water heating operating mode 8 Water heating duration 5 min to 1 hour 35 min Standard 30 min Setting the duration for water heating in the heating and water heating operating mode 9 Hot water immersion heating function YES NO Standard NO Reset to factory settings
46. m2 2 way directional valve connected Yes No Terminals 1 2 3 3 way directional valve connected Yes No Terminals 4 5 6 Electric immersion heater for hot water tank connected Yes No Terminals 7 8 earth 3KW max output Room thermostat connected Yes No Terminals 9 10 11 12 OLP hot water tank connected Yes No Terminals 13 14 Programming Connection of hot water tank to Yes Important If the hot water tank is connected to Yes and no OLP is used then jumper terminals 13 14 Hot water tank connected Yes No Terminals 15 16 Programming Connection of hot water tank to Yes Ext control signal connected Yes No Hemove jumper from terminals 17 18 oolar 3 way directional valve connected Yes No Terminals 19 20 21 Programming Connection of hot water tank to Yes Solar pump station connected YVes No Terminals 22 23 Compact unit installation Can condensation drain freely Yes No Are all minimum clearances observed Yes No Aquarea air water heat pump Installation manual for compact systems 03 2013 11 51 Appendix Panasonic Commissioning report ideas for life Commissioning report Panasonic ideas for life Parameter list Low outside temperature l Operating mode l Function Out Lo in C Operating display High outside temperature Pry HEAT Out Hi in C Heating priority Ves No Water supply target temperature at out Lo No
47. n heater for hot water Setting the delay period before the immersion heater is switched on for the hot water tank if the tank temperature is not reached 20 min to 1 hour 35 min Standard 1 hour Sterilisation YES NO Standard YES Setting for sterilisation of the hot water Note If Heating priority is set to YES steps 12 to 14 are skipped Day and time of sterilisation Standard Monday 12 00 noon Setting the day and time of weekly sterilisation even when the device is switched off Sterilisation temperature Setting the temperature to be used for sterilisation 40 to 75 C Standard 70 C Sterilisation duration Setting of the period required to retain the tank temperature needed for sterilisation 5 min to 1 hour Standard 10 min Sterilisation only appears if the TANK is set to YES Aquarea air water heat pump Installation manual for compact systems 03 2013 8 41 Commissioning Panasonic Programming Special functions ideas for life OUTDOOR ACTUAL TE E ees F m I HEATER pI isis m BOOSTER a E E amp 5 um MNETEWD TN IR H WATER OUTLET OFF ON Q STATUS SETTING STATUS MODE CHECK CHECK QUIET HEATER SEARCH ce oU ERROR RESET e e SEARCH Set the individual special functions as follows Press the SET and CHECK buttons for 5 seconds to switch to Programming mode for the special settings The SETTING programming and STATUS displays syste
48. n the outside temperature 3 and corresponds to the required temperature of the hottest heating circuit for mixed heating circuits Heating circuits with lower supply temperatures must be adjusted to the right temperature using heating circuit mixers 4 to be provided by the customer by adding return heating water A room thermostat to be provided by cus tomer deactivates heating mode of the heat pump when it reaches the target room temperature and prevents further activation and deactivation of the heat pump An overflow valve between the supply and return pipes ensures that the minimum volume flow of the heat pump is guaranteed even with thermostatic radiator valves and heating circuit mixers 1T2TsT Ts Te S TeTo honk H e povut CL 3 7 sv o m om P T 8 F i eA T g SEE ee ae d AN 2 a er ac S N r cs eo 9 rmowg4 J D D EEE M 26 avecereseeeeceeceeeeetae AX D 0 0 0OC QQe 00 0U e 2 408d 2 E 5 Oo ot ae ee LL gt o 5 5 Q THE fran xe j 9 up U lt XK D Sete M PA Y tk He 501 rDEH HX C Vessel
49. ransferred via an internal connection Laying the cables inside the device Laying the cable into the device If necessary open the compact unit as described in Section 5 Cut into the cable gland in a cross shape using a knife Route the cables through the enclosed cable gland on the right side of the housing to prevent the cables being damaged by sharp edges Connect the cables to the terminal strips as in the above overviews Make sure you use the correct connections oecure the cable using adhesive tape and cable ties as shown in the figure Ensure that the cables cannot come into contact with hot device parts Aquarea air water heat pump Installation manual for compact systems 03 2013 Electrical installation Panasonic Installing the wired remote control ideas for life 7 3 Installing the wired remote control Warning Please follow these instructions to prevent damage and problems Do not change the length of the cable for the wired remote control Install the wired remote control cable at least 5cm away from other electric cables Do not install the wired remote control cable in the immediate vicinity of water or condensate pipes The installation location must be dry The wired remote control must be installed so that it is not exposed to direct sunlight Mount the wired remote control in as level a location as possible to prevent the wired remote control bendin
50. ropeninouccorunt Fas cooing nigh pressure guardinoutdoorunt a Unstable output beween the indoor and outdoor unt 0 seconds alier supply ferent WS Compressortomperaure sensor Sseendsbng Wm Liu temperature sensor eseon Fa Problems inthe cooing out Weinen mies wm jGmpewrbepwmm 0 0 02 Ha waersde tow rasco sends e Horpresswesensor eseon m i 76 Communicaton ets or operator conoi paneron mdoordevee hoo Communication enor between indoor and outdoorunit 60 seconds afier stan of operan We OLP ecri mmerson eatrfornotwatertank Ssecondsbng Hos Indoovoudcoruntincoresty comected we Hon pressure guardinoutdoorunt e Aniteezeforindooruntheat exchanger N C2 NEN N Aquarea air water heat pump Installation manual for compact systems 03 2013 11 57 Appendix Error codes 1 Display of system errors CHECK button SEARCH UP DOWN buttons A c N Error reset button ERROR RESET 5 CANCEL button 11 58 Panasonic ideas for life OUTDOOR ACTUAL 8 MeRi mja T Bien i A ua g ee BOOSTER NK mcs l i C gm DEFROST 2 00 00 jm sme E f SA ERR E ig STATUS s C om SERVICE WATER OUTLET OFF ON 1 If an error occurs during operation the system stops the OFF ON LED flashes and an error message is shown on the display The error code is stored in the EEPROM of the indoor unit Acknowledging the error code Press
51. s been performed completely and correctly Pass all documents to the end customer and instruct them to store the documents in a safe place Explain to them how to operate the unit and sign the handover report and acceptance certificate see Appendix together with the customer Aquarea air water heat pump Installation manual for compact systems 03 2013 Panasonic Ia Commissioning Programming Display Button assignment 8 2 Programming Note As the same operator control panel is used for different devices some functions may not apply for your device Displays 10 11 12 13 14 15 16 Operation LED Display of external room thermostat Display of solar installation Display of operation of additional electric heater for heat pump and emergency heating mode ON OFF Display for quiet mode ON OFF Hot water tank operation display ON OFF Cooling operation display ON OFF The operator control panel of the SDF models has no display for cooling mode Heating operation display ON OFF Display of timer setting and time Display of outside temperature Display of water outlet temperature Display of additional electric heater for the heat pump and the electric immersion heater for the hot water tank ON OFF Display for defrosting ON OFF Display for system program ming ON OFF Display for system status ON OFF Display for service ON OFF OFF ON 1
52. s have the correct polarity If this is not the case electric shocks or fire can result Ensure that the cables can never come into contact with hot objects such as the water pipes High temperatures can damage the insulation Observe the following specifications for installation Incorrect Correct Incorrect Incorrect T E ed min 5 mm The clearance between the cables must be at least 5 mm Clamping screw connection Tightening torque NM 157 196 196 245 Aquarea air water heat pump Installation manual for compact systems 03 2013 Electrical installation Panasonic Mains connections ideas for life 7 1 Mains connections Mains connection for compact unit Mains connection for compact unit 9 kW three phase 6 to 9kW single phase o UBg o U 1 1 2 qa 2 Goco POWER SUPPLY 1 d L N ue Se ss E Power supply 1 Power supply 2 Power supply 1 Power supply 2 1 Compact unit and 2 Electric immersion heater 1 Compact unit electric immersion heater additional electric heater for hot water tank 2 Additional
53. standard pumps and high efficiency pumps as described in the two following sections Pump operating head kPa Pump operating head kPa 0 5 10 15 20 25 Flow rate I min 40 50 60 0 10 20 30 Flow rate l min CO Characteristic curve of the standard circulation pump for the Aquarea heat pump 7 and 9 kW single phase Characteristic curve of the standard circulation pump of the Aquarea heat pumps 9 kW three phase and 12 14 and 16 kW single and three phase 2 E E o O The circulation pump offers three speed levels If necessary set the circulation pump to a higher speed level e g if the flow rate is too low or a slower speed level e g to decrease noise If setting the speed of the circulation pump does not solve the problem contact an authorised dealer After the test run clean the dirt trap See Section 9 4 Commissioning Commissioning Setting the high efficiency pump Handover and instruction Panasonic as for life 8 1 2 Setting the high efficiency pump A Warning Hydraulic decoupling between the heat pump circuit and heat consumer circuit is always re quired when using Aquarea heat pumps with high efficiency pumps overflow valves may not be used If hydraulic decou pling is not implemented the flow could fall below the mini mum volume flow which results in error messages on the
54. t trap to be provided by the customer upstream of Hydraulic decoupling between the water inlet water return of the compact unit grid width at least the heat pump circuit and heat 500 to 600 um to protect the heat pump We recommend installing 6 emitter circuit is always required a shutoff valve upstream and downstream of the dirt trap to make when using Aquarea heat subsequent maintenance work on the dirt trap easier oe SS E E 53 Ss I E pumps with high efficiency Install an overflow valve if no hydraulic decoupling e g hydraulic pumps overflow valves may switch or storage tank is planned Ensure that the overflow valve Oe ERE is not designed for the minimum volume flow but for the nominal volume flow of the respective heat pump A Warning If a heat pump with a cooling function is used install a 2 way direc In cooling mode humid air can tional valve to deactivate the heating circuits in cooling mode where condense on the surface of the applicable heat transfer systems if the temperature drops below the dew point This can damage the building or make the floor slippery As a result you must install suitable positioned dew Install the 3 way directional valve to be provided by the customer to switch from heating mode to water heating mode and vice versa As standard the valve should be open towards the heating circuit contacts 4 and 6 are closed The valve must also be CE compliant and ma
55. te Setting heating priority HO Lo in C over hot water heating Water supply target temperature at out Hi HEAT H O Hi in C Duration of heating in heating and hot water mode in hours Target temp to deactivate heating mode TANK Heating limit temperature in C Duration of hot water heating in heating and hot water mode in h Outside temperature for activating the additional Booster electric heater in C Water heating l Yes No dly BOOSTER in C owitch on delay for electric immersion heater for hot water tank in hours Fun otrL Target temperature of the hot water tank in C Siarilicaton Yes No Operating mode Day and time of sterilisation Function y Operating display StrL con toon Sterilisation temperature in C External room thermostat Yes No Note At sterilisation temperatures over 55 C the electric immersion heater for the hot water tank is always used Selection of the output of the additional electric oPr otr heater for the heat pump oterilisation period in min 3kW 6kw okw The parameters from Pry on are only shown if TANK is set to Yes con TANK l The parameters int to dly are only shown Connection of hot water tank _ Yes _ No if Heating priority is set to No SOLAR Solar priority Yes No Note Set to Yes where possible as otherwise the Pump level service water is mainly heated by the heat pump Level 1 Yes No instead of solar thermal energy Level 2 Yes No Level
56. ter tank HR 200 200 litres HR 300 300 litres Stainless steel tank Enamelled Enamelled Sensor with cable and immersion sleeve for installation in third party tanks Hot water tank HR 300 300 litres HR 500 500 litres Temperature sensor installation set CZ TK1 for third party tanks Additional casing heater unit CZ NE1P for series Aquarea T CAP Aquarea HT Aquarea LT series mini compact units Heating band attached on the floor plate inside the unit s casing to prevent the water incurred during defrosting from freezing 3 12 Aquarea air water heat pump Installation manual for compact systems 03 2013 Location Installing the device Panasonic 9 Location ideas for life 4 Location Installing the device 4 1 Location Weights of the compact units Aquarea LT single phase one fan 112kg Aquarea LT single phase 153kg Aquarea LT three phase 157 kg Aquarea T CAP single phase 155kg Aquarea T CAP three phase 158kg Aquarea HT n a The installation location must meet the following criteria I General Even and horizontal Load bearing see device weight table e No outside temperature under 20 C es 2E Ow 8S 7 GE Installation at a height sufficient to protect against weather influences such as snow or water levels The height difference of the liquid system circuit may not exceed 7 m Easy access for maintenance work Condensate must drain away easily No damage
57. the wired remote control 7 3 f Commissioning Aquarea air water heat pump Installation manual for compact systems 03 2013 1 7 Safety instructions Panasonic Hazard instructions for avoiding electric shock and damage to health r lif 2 Safety instructions 2 1 General hazard instructions for avoiding electric shocks Danger Observe and comply with the following hazard instructions If you fail to do so there is a danger of electric shock or fire Only qualified electricians may perform the electrical installation work All service and maintenance work must also be performed by a certi fied electrician or an authorised dealer Keep children and persons who are unfamiliar with the system clear of the working area When working on the device comply with the national and local standards and regulations The cables and electricity connections including existing connec tions must be suitable for the electrical capacity of the heat pump Do not use non approved mains cables modified cables or extension cables to connect to the electricity mains The device must be earthed correctly It may not be earthed to gas or water pipes lightning conductors or the earthing of the telephone system Comply with the respective national wiring rules and safety precautions for fault current Panasonic recommends that you use a RCD 2 2 General hazard instructions to avoid damage to health Danger Observe and comply with t
58. to other objects if water leaks If a solar installation is connected the connection cable between the solar pump station and the compact unit may not be longer than 10 metres Minimum clearances The minimum clearances see Figure must be observed 1 Minimum clearance 100mm 2 Minimum clearance 300 mm A 3 Minimum clearance 1 000mm Minimum clearances of the compact unit to adjacent walls and objects indicating the air flow direction Aquarea air water heat pump Installation manual for compact systems 03 2013 4 13 Location Installing the device Panasonic Location A Te Coane ffs ga T ff om Ideas for ire Air circulation In general choose an installation location with good air circulation No additional guards such as awnings etc No sources of heat or steam nearby No objects nearby which could short circuit the exhaust air No direct wind impact on the suction side of the unit f multiple units are used observe the minimum clearance between units Incorrect Incorrect Correct 1 Minimum clearance 100mm Correct alignment of multiple external or compact units O Note Soundproofing The design handbook for split he operating noise of the compact unit must not bother the user
59. ton or wait 30 seconds to exit Setting mode Press the SET button to confirm the setting Water temperature Halia Wai H i out Lo aut Outside temperature Aquarea air water heat pump Installation manual for compact systems 03 2013 8 39 CO 2 E E o O Commissioning Programming Weather compensation settings Operating mode Panasonic ideas for life Weather compensation settings ACTUAL Water temperature P LIE a Value of TF e temperature Lm i target value Fo i shift mak ia PeH Outside temperature out Lo Low outside temperature out Hi High outside temperature H OLo Water target temperature at low outside temperature H O Lo Water target temperature at high outside temperature Setting the operating mode HEAT HEATER COOL BOOSTER TANK u QH 4 DEFROST QUIET zs n SETTING HEATER CWETCHE e STATUS FORCE SERVICE orem WATER OUTLET OFF ON T e SETTING STATUS SETTING MODE CHECK QUIET HEATER SEARCH W SELEC ERROR RESET FORCE SERVICE CANCEL 9 e Set the temperature shift as follows Press the SET button gt 5 seconds SETTING is shown on the display Press the SELECT button to select the temperature shift Use the UP or DOWN buttons to enter the required value 5 to 5 C Press the SET button to confirm the setting Press the CANCEL button or wait 30 seconds to close the entry OUTDOOR ACTUAL TANK E
60. ue wrench 58 8 Nm Knife Gas leak detector The following components must be provided by the customer 2 way directional valve set Propylene glycol antifreeze 3 way directional valve set mixture Analogue room thermostat e g Flush mounted box for fitting RAA20 Siemens or program the wired remote control mable room thermostat Heating circuit mixer closed e g REV200 Siemens loop control Anchoring to prevent tipping over Dew point monitor Dirt trap mesh width at least Device for draining the system 500 to 600 um nsulation for pipelines Aquarea air water heat pump Installation manual for compact systems 03 2013 Introduction Panasonic Installation sequence ideas for life 1 1 7 Installation This installation manual is written so that the sequence of sections sequence corresponds to the sequence of installation steps to be performed These are primarily as follows TIMER HEAT a COOL w s 131418 SETTING STATUS TIMER SET MODE CHECK A OFF ON wo SELECT QUIET HEATER SEARCH yp ERROR CLOCK CANCEL or 2o En e ff A Neg ARO OCSOsegence ee erse UY Mevetcocteciuces lessees CrwseeteercsectesS ores Yy 77 Installation step Installing the device Connecting the water pipes Filling and venting the system Connecting the device to the electricity mains 7 1 Connecting inputs and outputs interfaces 7 2 Installing
61. y not exceed the peak load of 12 VA point sensors to ensure that Use Rp 154 nuts to connect the water inlet labelled WATER IN and temperatures lower than the water outlet labelled WATER OUT Use a torque wrench to tighten dew point do not occur or drain it and apply the correct torque 117 6 Nm any condensate which forms reliably In addition the pipe lines affected must be insulated impermeably Close the supply water outlet and return water inlet of the compact unit at the heat exchanger of the hot water tank Ensure that you do not confuse the connections supply top return bottom Install a device for draining the system to be provided by the customer Aquarea air water heat pump Installation manual for compact systems 03 2013 6 19 Hydraulic installation Panasonic ideas for life Insulate the pipes in accordance with the latest UK building regulations although the below is recommended Type of pipes Fittings Minimum thickness of insulation layer Internal diameter from 35 mm to 100mm 2 xinternal diameter Recommended thermal insulation of heat distribution and hot water pipes A Warning The customer is responsible for ensuring that the device does not In compact systems there is a freeze Please use one of the following options to do so risk of freezing if the heating cir cuit is filled with water and the outside temperature falls below 0 C That can cause significant An additional he