1. Ringer Equivalence Number The REN of the Digi Modem apparatus is 1 0 To ensure correct ringer operation of other equipment connected to the same telephone line then the sum of RENs of the individual items connected to one PSTN line should not exceed 4 D3000 Series Installation Manual D3000 INST O9H v3 66 PSTN Line Connection Options The control panel s line connection requires an analogue telephone line For connection to other types of telephone line refer to the previous pages Connecting other telecomms equipment IN PARALLEL to the analogue telephone line used by the control panel can stop the unit sending alarm calls to an Alarm Receiving Centre Parallel connection MUST NOT be used for the control panel when it is used in a security system There are several ways that the control panel may be connected to a PSTN telephone line particularly when other equipment needs to share the same telephone line Some require that your Telecom Service Provider supplies particular line features Some require the control panel programming options Refer also to the safety Earth and the Call Minder sections The highest security PSTN line for the Control Panel Recommended Note Up downloading via the PSTN will be inhibited A PSTN line supplied as outgoing calls only i e Incoming Ringing Barred AND the PSTN line is ex directory AND the PSTN line goes to the Control Panel Digi Modem ONLY Other equipment can
2. Control Panel or ADD8PSU Typical SCB ve Holdoff ve Hokdoff Fig 104 shows a typical SCB Self Contained Bell connection The tamper TAMP terminal is connected to Ov via the RTN terminal The normally closed tamper switch will be connected to the SCB on other terminals This example shows a closed loop tamper circuit Not EOL The bell siren is commanded to sound when the TRIG terminal is switched to Ov An SAB includes a small battery and this together with the 12 volt supply from the control panel will operate the bell siren unit The strobe is driven from the control panel 12v supply when the STR terminal is switched to Ov In this example the strobe must not draw more than 500mA maximum current Control Panel or ADD8PSU IF S Typical SAB fe Bell ve Holdoff Ball ve Holdoff H2v nax O amp Tamp va Tamp Return 2K2 2K2 p ORn Trig S 1 S 37 3 Sr E g Fig 105 or Siren Fig 120 shows a typical SAB Self Activated Bell connection The tamper TAMP terminal is connected to Ov via the BELL terminal The normally closed tamper switch will be connected to the SAB on other terminals This example shows a separate EOL resistor of 2200 ohms some SABs include a 2200 ohm resistor The bell siren is commanded to sound when the TRIG terminal has its normal Ov switched off An SCB includes a battery and this will operate the bell siren unit The strobe is driven from the control panel 12
3. Modem D3000 Series Installation Manual D3000 INST 09H v3 73 The Call Minder call answering Service Some telecom Service Providers offer a call answering service This will answer incoming calls if the subscriber s telephone is not answered within a number of rings The Control Panel programming does not need changing when this service is provided This service is available from BT in most areas of the UK on Analogue PSTN ISDN Home Highway and Hybrid ADSL lines It may also be available from other telecom Service Providers The Control Panel may be connected to lines offering this service See earlier connection information This service indicates to the subscriber that an earlier call has been recorded and should be heard by pulsing the dial tone on subsequent calls See the Table 36 Dial Tone Type Dialling Answered calls Continuous You may dial There are no answered calls Pulsed You may dial There are answered calls waiting to be heard Table 36 The Control Panel is normally programmed to require a dial tone of 0 1 second before it will dial the number of the ARC to send its alarm information This timing will operate with continuous and pulsed dial tones Safety Earth connection Some equipment designs provide electrical safety with no Earth connection for the telephone line The D3001 D3011 D3021 and D3022 Control Panels are of this type Connecting to a Stand Alone Dual Path Signallin
4. UK VDN Approval The CS1070 VDN radio module product incorporates an independently tested and approved Vodafone Data Network radio module that meets the requirements of UK radio communication standards International GSM Approval The D2070 GSM Radio Module product incorporates an independently tested and approved GSM radio module that meets the requirements of international radio communication standards The GSM Radio Module Approval Authority is 0165 European Wire free Detector Approval The D2070 GSM Radio Module product incorporates an independently tested and approved GSM radio module that meets the requirements of international radio communication standards The 868 MHz Detector Approval Authority is 0165 D3000 Series Installation Manual D3000 INST O9H v3 105 APPENDIX 7 Glossary of Terms ADD Additional Connection Point A junction or connection box on the control panel bus wiring that allows connection of detectors and output devices e g ADD8 8 FSL inputs 4 programmable outputs and 1 sounder output Sometimes called a Line Interface Module Zone Expansion Module or Line Expansion Module ADSL Asynchronous Digital Subscriber Line A wideband digital communication service from a network provider to a subscriber that carries a high volume of digital data most commonly for internet access Sometimes called broadband An ADSL service is often provided with a simultaneous analogue PSTN service on a hybri
5. 94 APPENDIX 1 cont d Other Methods of VDN and GSM Signal Strength Testing A Dualcom aerial and fully charged battery may be used to survey a proposed site for the point of strongest signal For the VDN network a VDN Dualcom will be required For a GSM network a GSM Dualcom will be required Ensure that the Dualcom is fitted with an NVM and is fully operational Walk around the site carrying the Dualcom aerial and battery observing the signal strength LEDs When you have identified the point of the strongest signal make a note of this point and use it when installing the aerial Alternatively a control panel with VDN or GSM radio modem aerial keypad and fully charged battery can be used to survey a proposed site for the point of strongest signal This option is ungainly but it does work For the VDN network a VDN radio modem will be required For a GSM network a GSM radio modem will be required Ensure that the control panel radio module and keypad is fully operational Walk around the site carrying the equipment battery and aerial observing the signal strength indication on the keypad When you have identified the point of the strongest signal make a note of this point and use it when installing the aerial D3000 Series Installation Manual D3000 INST O9H v3 95 APPENDIX 2 Site Range Survey for Wire free Detectors To ensure that the wire free detectors can be reliably received a range survey should be conducted befor
6. See D3000 Programming Manual for further information The proximity reader controller must be mounted inside the protected area The tag reader may be connected inside or outside the protected area The tag reader case measures 110 x 25 x 25 mm and mounts directly onto a wall using the 2 mounting holes in the base of the case The cable is fed through the square hole provided and must be fed directly through the wall to ensure that the housing sits flush on the wall To open the tag reader housing a screw will be visible at the bottom Loosen this screw do not remove it completely and gently remove the cover from the base To mount the tag reader on a wall first open the housing and separate the two halves Present the base to the wall then mark the position of the 2 fixing holes and the hole needed to feed the cable through the wall ensure that the base is upright when marking the wall Remove the base and drill the wall Fix the base to the wall feed the cable through the wall and fit the tag reader to the base Finally tighten the screw at the bottom of the housing The cable assembly is fed to the controller and connected to the colour coded terminal blocks R Red BLK Black Y Yellow G Green BLU Blue W White The proximity reader controller is fitted in a standard Add8 housing measuring 168 x 108 x 35mm h x w x d For further information on mounting this housing see the section on the Add8 on page 36 Reader 1 Ta
7. that is closer to the items requiring the current then the voltage drop along the 5Ometre section of wire is O because the current flow has been reduced to 0 Fig 91 Reduced Voltage Drop Example D3000 Series Installation Manual D3000 INST O9H v3 79 System Bus Wiring cont d ADD8PSU Bus Connection The ADD8PSU connects onto the bus and supplies 12 volt power onto the bus from its network OUT terminals away from the control panel The 3 Amp power supply built into the ADD8PSU supplies the current to operate itself to charge its battery s and to feed power onto the Bus from its network OUT terminals The same monitoring functions of the control panel power supply are present in the ADD8PSU power supply The monitoring information is fed along the bus to the control panel A na 6 BO c ad D 09 1ZVOLTS The ADD8PSU takes no power from the bus on its network IN terminals See Fig 92 Connect the network IN A B C and D terminals on the bus towards the control panel This applies to each ADD8PSU no matter how many ADD8PSUs are used on the bus Connect the network OUT A B C and D terminals on the bus away from the control panel This applies to each ADD8PSU no matter how many ADD8PSuUs are used on the bus When calculating wiring voltage drops and battery capacities remember that power flows onto the bus from the ADD8PSU network OUT terminals and it flows away from the control panel The ADD8PSU takes no
8. 136 The Control Panel cannot be directly connected to a digital telephone line An ISDN2 line can be provided as point to point or point to multipoint Where there is only one item connected to the S bus then a point to point service is OK Where two or more items are connected to the S bus then a point to multipoint ISDN service must be provided Contact your telecomm Service Provider for details of the ISDN services that they can provide Control Panel Qualcomm Digicom or other ISDN2 service provided by the Network Service Provider The S bus from the NTP can go lo several different Kams of equipment ISDN2 Line DO700 Converter Fig 78 D3000 Series Installation Manual D3000 INST O9H v3 70 Home Highway Business Highway Home Highway and Business Highway is the marketing name for a basic rate ISDN2 line supplied by BT with an NTE9 or similar NTP The NTE9 NTP provides two S bus sockets it includes an ISDN Analogue converter and two analogue telephone sockets This type of NTP can have an analogue telephone fax modem etc connected at either or both of the analogue telephone sockets The control panel may be connected to these analogue sockets See Fig 79 Power for the NTE9 comes from the exchange equipment via the ISDN line and also from the mains supply at the user s premises In the event of mains failure the right hand analogue telephone socket on the NTE9 will cease to
9. 7 Opas Signaling 3 or 16 Channel Fast Format Gortact ID S Auaierneaom 6 te eee we eee Sites Keypad Programmer Refer to Appendix 4 for the Downloader Current Consumption of all units D3000 Series Installation Manual D3000 INST O9H v3 5 Part Numbers D3001 D3011 D3021 D3022 D2070 D3024 D3025 D3202 B D3211 B D3212 B D3205 D3232 D3233 D3240 D3300 D3301 D3500 D3510 D4809 D4810 D4811 D4812 D4814 D4815 D4830 D4831 D4832 D3054 D0730 216 zone control panel Case size 2 x 7Ah batteries 216 zone control panel Case size 2 x 17Ah batteries or 4 x 7Ah batteries 52 zone control panel Case size 2 x 7Ah batteries 52 zone control panel Case size 2 x 7Ah batteries GSM radio modem A panel plug on accessory Output board A panel plug on accessory Audio board A panel plug on accessory Multimedia keypad As D3201 multimedia keypad card tag prox reader Lo Cost keypad Keypad no i p no o p no sounder o p no audio Lo Cost keypad As D3211 keypad card tag prox reader Engineers Keypad As D3202 multimedia keypad plug in connection and cased Proximity reader Card tag prox reader external reader IP sealed Proximity reader sensor Additional sensor for use with D3232 IP sealed Proximity tag Key fob style for use with D3202 D3212 and D3232 ADD8 8 FSL wired zone inputs 4 programmable outputs sounder o p ADD R receiver 868MHz for wir
10. Board location on a D3001 or D3011 Mk2 Control Panel Fig 57 When the audio helpline is in operation the operator at the Help Centre can control the call using the push buttons on their telephone Push Action 5 Toggle listen talk 7 Listen 8 Talk 9 Shutdown D3000 Series Installation Manual D3000 INST O9H v3 52 Wire free Detectors D4809 Pet tolerant Wire free PIR Detector Manufacture marking IRP 9 The Pet Tolerant Passive Infra Red Movement Detector D4809 is designed to eliminate the possibility of false alarms due to pets up to 27 kg Installation 1 Ensure that the location chosen for this item and the location s of the receiver s will provide a sufficiently strong radio signal to be received Refer to site range survey for wire free detectors page 5 Loosen the single screw on the lower end of the PIR detector and remove the back plate Fit the batteries in their holder The LED will flash for 30 seconds during warm up Fit the Test Jumper in the Test position a FON Learn in the PIR movement detector to the receiver or control panel by pressing the Test button 6 Select the mounting position so that the PIR is overlooking the required area See Detection Coverage below Check operation with the LED 7 Using that position mount the PIR back plate using the screws provided This may be ona flat surface or in a corner depending upon which case knock outs are used Wher
11. Control Panel Fig 93 D3000 Series Installation Manual D3000 INST 09H v3 81 Zone Inputs The control panels the keypads the ADD8 and ADD8PSU all have zone inputs for detector connection The zone inputs can be connected as FSL loops terminated by three resistors OR For tamper applications only they can be wired as EOL loops and terminated by one resistor NOTE The closed loop connection that uses no resistors must not be used on zone inputs See Fig 96 A three resistor FSL loop can signal 5 states to the alarm system these are normal 2K2 fault masked 4K4 active 6K9 masked 9K1 and tamper open or short circuit See Fig 94 This wiring configuration complies with the requirements of PD6662 for Grade 2 and Grade 3 NOTE to monitor for fault and masked conditions the CIE must be fitted with software version 5 000 or later and all ACE must be fitted with software version 2 00 or later A one resistor EOL loop can only signal 2 states to the alarm system these are normal and tamper An EOL loop can only be used for tamper circuits it cannot be used where five state normal active fault masked masked and tamper signalling is required See Fig 95 All control panels keypads ADD8s and ADD8PSUs that have zone inputs are supplied with the necessary resistors Note that there are two different types of resistor r
12. Detectors cont d D4820 Long Range 4 Channel Transmitter cont d Input Connections Each of the 4 channels is triggered by breaking an electrical connection between its input terminals marked Z1 to Z4 This is most easily arranged by a normally closed switch or relay contact When the electrical connection between each channel s input terminals is re established then a restore transmission will be sent LED Indicator There is a red LED on the unit This LED will to be on whenever the 4 channel transmitter is sending a signal Learning in Each channel of the 4 channel transmitter is learnt in to the control panel by pressing the test button for that channel Tamper Detection The tamper switches and spring will detect the lid of the 4 channel transmitter being opened from its back plate or when the whole unit is removed from its mounting An external normally closed loop and or switch es may be connected to the A T Terminals When this is unused then a link must be placed across these terminals Radio Transmissions The radio transmitter in the unit will send the following signals for each channel Alarm signal when the input loop on that channel s input terminals is opened Restore signal when the input loop on that channel s input terminals is closed Test signal also used for learning in will be sent when the test button is pressed The radio transmitter in the unit will send the following signals Tamper signal whe
13. Figure 145 shows a D3021 control panel that is connected in the middle of the system bus Figure 146 shows a D3001 control panel that has 2 system buses The control panel is connected in the middle of the system bus 1 The control panel is connected at the end of the system bus 2 D3021 with 1 System Bus Keypads ADD 6 and ADD R Fig 84 D3001 with 2 system bus keypads ADD 8S and ADD Rs on each bus Fig 85 D3000 Series Installation Manual D3000 INST O9H v3 75 System Bus Wiring cont d The system bus terminal connections at each unit are labelled A B C and D The use of the system bus connections are shown in Table 40 with recommended wiring colours It is essential that A B C and D on one unit is connected to A B C and D on all subsequent units Incorrect connection will not result in damage but will result in incorrect Control Panel operation See Fig 86 Bus Network Connection Use Wiring Colour A 12 volts Red B Ovolts Black C Data Yellow D Data Blue Table 40 The keypads and some other units only have single bus terminals Due to increased space ADD8s and some other units have double bus terminals Double bus terminals are provided to ease wiring connections only either or both terminals may be used for bus connection See Fig 99 and 100 Control ADD ADD Panel firErm freru A MAA AAO B SB B BBO C Occ c cO D No D i D DO 1000 metros ma
14. MUST NOT be opened There are no user serviceable parts inside All control panels are fitted with a fused terminal block for connection of a 230 volt AC mains supply The 230 volt AC mains supply should only be connected to the fused terminal block by a qualified electrician Always observe electrical safety precautions If the supplied fuse should fail determine the cause of the failure before replacing the fuse and only replace it by one of a similar type and rating When closing the case 1 Ensure that no wires are trapped between the back and lid or trapped around the tamper switch 2 Ensure that the safety earth wire is fitted from the case back to the push on connector on the lid 3 Do not use longer screws that those provided when securing the lid to avoid damage to internal batteries or wiring D3000 Series Installation Manual D3000 INST O9H v3 19 D3001 and D3011 Control Panels D3001 11 Installation The lid of the control panel is secured by 2 screws To open the case remove these screws then remove the lid Note how the lid fits into the back of the case To mount the control panel on a wall first remove the circuit board to avoid damaging it Remove the 2 top screws holding the circuit board loosen the two lower screws holding the circuit board then remove the circuit board from the control panel case See Fig 24 and 25 Mark the position of the case single top mounting Drill the wall then mount the case u
15. Output 4 Table 46 D3011 Control Panel Output 1 Output 2 Output 3 Output 4 D3021 Control Panel Output 1 Output 2 Output 3 D3022 Control Panel Output 1 Output 2 Output 3 D3201 Output 1 Keypad Output 2 D3202 Output 1 Keypad Output 2 Output 1 D3300 Output 2 ADD8 Output 3 Output 4 D3500 Output 1 Output 3 ADD8PSU Output 2 Output 4 D3510 Output 1 Output 3 ADD8PSU Output 2 Output 4 D3000 Series Installation Manual D3000 INST O9H v3 88 Power Supplies and Batteries The D3001 and D3011 control panels and the ADD8PSU each incorporate a 3 Amp Switched Mode PSU module with safety and monitoring features to meet the requirements of the most demanding situations amp standards Each power supply can supply 3 0 amps under all conditions The actual current is constantly measured and may be displayed on Keypads and via the up download programming software The D3021 and D3022 control panels incorporate a 1 2 Amp Switched Mode PSU module with safety and monitoring features to meet the requirements of the most demanding situations amp standards The D3001 control panel and D3500 ADD8PSU have space to accommodate one or two 7Ah batteries size 155 x 105 x 70mm h x w x d The D3011 control panel and D3510 ADD8PSU have space to accommodate one or two 17Ah batteries or up to four 7Ah batteries size 170 x 180 x 80mm h x wx d The installer must ensure that the power available from the power supplies in the control panel including any additio
16. These are for connecting to the case tamper switches on the control panel ADD8PSU and associated equipment In addition the TAMP terminal is the connection to the tamper loop from the bell sounder s and strobe unit s The D3001 and D3011 control panels have 3 tamper inputs These are tamper 1 lid tamper switch tamper 2 and bell tamper Where unused these must be terminated by a closed loop shorting link or a 2200 ohm resistor The D3021 control panel has 1 tamper input This is the bell tamper Where unused this must be terminated by a closed loop shorting link or a 2200 ohm resistor The D3500 ADD8PSU has 2 tamper inputs These are tamper 1 and bell tamper Where unused these must be terminated by a closed loop shorting link or a 2200 ohm resistor Each tamper inputs can be connected as closed loop connection they use no resistors OR They can be wired as EOL loops and terminated by one 2200 ohm resistor The programming of the control panel must select the type of tamper input Closed Loop or EOL resistor Refer to the programming manual When a tamper input is used then it must be wired as shown in Fig 98 to 100 below All other tamper wiring should be connected to zone inputs See previous page 2200 ohms All red or red red ed __ Programme Control Panel ane for EOL Tamper Input Normally closed s contacts EOL Tamper Inputs Fig 98 Normally open contacts Diaa ee Zone Pr
17. Zone5 8 r 3 7 Tamper Switch Bus terminals Engineers Keypad Programmable Internal Sounder Sonea outputs output D3021 and D3022 Control Panel Circuit Board Fig 29 D3000 Series Installation Manual D3000 INST 09H v3 26 D3021 and D3022 Control Panels cont d Tamper Inputs The D3021 22 control panels have a tamper input and a bell tamper input Where unused these must be terminated by a closed loop shorting link or a 2200 ohm resistor See page 89 LED Indicators The D3021 22 control panels have several indicator LEDs See Fig 30 The PSTN LED will be lit whenever the control panel s built in Digi modem is on the PSTN line making a call or up down loading The ACTIVE LED will flash to show correct operation See Table 16 Active LED Indication Meaning 2 flashes in 1 second then Off for 1 second Normal Operation Fast flashing 3 flashes per second Programming Up downloading in progress Off Fault detected on Panel PCB On solid Fault detected on Panel PCB Table 16 Telephone Line Connection Connect the analogue PSTN telephone line to the A and B terminals Connect other equipment that can use the telephone line to the A1 and B1 terminals Refer to the connection recommendations on pages 71 to 78 for all PSTN options Current Consumption Refer to Appendix 4 for the current consumption of all units Note that an internal sounder if connected will require an additional 400mA Use these
18. address selector is set to a different number from each other ADD8 Make a note of the number for later programming See page 36 to 38 An internal sounder can be connected to an ADD 8 These items consume a lot of current Ensure bus wiring is sufficient See page 90 Connect wiring from detectors to zone input terminals on the ADD8 s as required Connect 12 volt supplies to detectors and other equipment from the ADD8 amp s AUX 12V terminals as required Connect wiring from internal sounders to the ADD8 s SND terminals as required See pages 36 to 38 Configure and install all ADD R units and connect to the bus cable as required Configure and install detectors See pages 44 to 47 and Appendix 3 Configure and install all ADD8PSU power supply units and connect to the bus cable as required The case and batteries can weigh up to 20 kilogrammes Select suitable mountings Connect detectors and output devices at each ADD8PSU as required See pages 39 to 43 Visually check and correct all wiring and connections You are now ready to power up and test the system System Testing Ensure you have informed your Alarm Receiving Centre that you are ready to test your alarm system 1 gt 00 Connect the battery or batteries to the BATT terminal s as required Observe electrical safety precautions See pages 18 to 27 The control panel may power up where the batteries are fully charged At all other times the control panel will n
19. and Batteries 105 Auxilliary Power Outputs 109 Table 10 Position for two optional ADD amp s Mains Terminal Block Top Mounting Board Fixings 17 Ah Battery F l ro F U 17 Ah Battery Lower Mounting I 7 Lower Mounting Board Fixings D3011 Control Panel Fig 25 D3000 Series Installation Manual D3000 INST O9H v3 21 D3001 and D3011 Control Panels cont d D3001 11Tamper Switch The case includes a tamper switch As supplied this is a lid tamper switch only To also allow it to be used as a back tamper switch requires the knock out removing in the rear of the case where the tamper switch activation lever rests See Fig 26 Fit a screw in the wall at this point so that the head protrudes through this knock out and holds the switch in its closed position To adjust turn the screw further into or out of the wall Note that the tamper switch may be defeated during installation by releasing the screw of the adjacent battery retaining clip and turning the clip to hold the tamper pin down See Fig 24 Rear of Case Tamper Switch Screw fitted in VVall Side view of Tamper Switch Fig 26 D3000 Series Installation Manual D3000 INST O9H v3 22 D3001 and D3011 Control Panels cont d Battery 1 Mains Supply LED AC Mains Connector Connector Kick Sta
20. be connected to the control panel s A1 amp B1 terminals i e series connection to make outgoing calls only The next best security option for a PSTN line Recommended A PSTN line supplied with the 3 way calling feature AND the D3000 system is programmed for 3 way calling AND the PSTN line goes to the control panel Digi Modem ONLY Other equipment can be connected to the A1 amp B1 terminals i e series connection for incoming and outgoing calls The no security option NOT Recommended A PSTN line supplied without outgoing calls only or the 3 way calling feature This option cannot cancel or hold incoming calls and these will inhibit the control panel from making a telephone call to the Alarm Receiving Centre The parallel connection option NOT Recommended The control panel s Digi Modem A amp B terminals connect to the telephone line AND other equipment connects directly to the same telephone line This connection option cannot cancel or hold incoming or outgoing calls and these will inhibit the control panel from making a telephone call to the Alarm Receiving Centre Your Telecom Service Provider should be asked to supply and fit a PSTN line and terminal block near the alarm system The alarm installer should then follow steps 1 2 and 4 below Note If the control panel is connected to the PSTN line AND a telephone or other equipment is sharing th
21. be inverted in the panel programming D3000 Series Installation Manual D3000 INST O9H v3 58 Wire free Detectors cont d D4812 Hand held Controller Manufacture marking RC 8L NOTE The D4812 does not use rolling codes so CANNOT be used in the UK to unset the alarm system as this does not comply with the requirements of DD243 2004 Installation Te The hand held controller has the smallest internal aerial and has the shortest range of all items in the D48XX range of Wire free devices Ensure that all locations from which operation is required and the location s of the receiver s will provide a sufficiently strong radio signal to be received Refer to Appendix 3 Wire free Detectors 2 On the rear of the unit slide the battery cover and remove it 3 Fit the battery in its holder Refer to Appendix 1 Batteries 4 Refit the battery cover 5 Ensure that the On Off switch is in the ON position 6 Press each of the 4 buttons Check operation with the LED 7 Learn in the hand held controller to the control panel by pressing each of the 4 buttons one for each channel learnt 8 When system testing is complete ensure that the On Off switch is returned to the OFF position On Off Switch e aii AW A p B 6 j J 4 Buttons pA os Handheld Controller Fig 66 Learning in Each channel from A to D is learnt in by pressing the associated button Handheld Controller LED There is a red LED on the front of the h
22. cont d Test Jumper Put this jumper in the ON position to ENABLE the LED Put this jumper in the Parked position to DISABLE the LED When the LED is enabled it will flash every time the unit transmits This can assist the alignment of the door contact and its magnet or when testing the alarm and tamper loops When testing is completed the test jumper should be put in the Parked position so that the battery life is not reduced and the units operation is not obvious to an observer Magnetic Switch Disable Jumper Put this jumper is in the ON position to DISABLE the magnetic switch Put this jumper is in the Parked position to ENABLE the magnetic switch Door Contact LED There is a red LED on the front of the door contact This LED will indicate tamper and low battery conditions by flashing when transmitting to alert the user that there is a problem In addition it will flash with every transmission when the test jumper is in the ON position Tamper Detection The tamper switch and spring will detect the lid of the door contact universal transmitter being opened from its back plate or when the whole unit is removed from its mountings Radio Transmissions The radio transmitter in the unit will send the following signals Alarm signal when magnet is moved away from the magnetic sensing area Restore signal when the magnet is placed against the magnetic sensing area Alarm signal when the alarm shorting link is opened Resto
23. engineer s code at any keypad Refer to the Programming Manual for details Engineers Reset One or more Groups Set When one or more groups are in the set state the control system may be reset following an alarm by first unsetting all groups from inside the control panel box then by use of the engineer s code at any keypad Refer to the Programming Manual for details Return settings to Factory Default values Once the engineering mode has been entered by one of the two methods above menu C 0 7 allows selection of any or all of 30 different resettable programmable parameters Any of these 30 parameters may be selected for returning to the factory default values Refer to the Programming Manual for details Help Desk Are you working from the latest version of the manuals Download all the current product manuals and all associated documents from the Dycon web site http www dyconsecurity com If you have installed the D3000 series alarm system in accordance with these instructions checked all the above points but are still experiencing signaling problems you can contact your equipment supplier your Telecom Service Provider or your VDN GSM Service Provider In UK between 09 00 and 17 00 weekdays all D3000 series installation programming operation or other questions may be addressed to Dycon Technical Support Tel 01443 471064 Fax 01443 479374 Email technical dyconsecurity com Web Site www dyconsecurity c
24. figures when calculating battery capacities Auxiliary Power Outputs The D3021 22 control panels have 2 auxiliary power outputs that can be used to supply 12 volt power to additional equipment These outputs are protected by a fuse that will automatically reset To reset the fuse disconnect everything from the outputs and wait 30 seconds Repair the fault and reconnect to the output See Fig 30 Auxiliary 12 volt power output 1 Auxiliary 12 volt power output 2 1 amp total from o p 1 and o p 2 for any additional equipment Refer to the section on auxiliary power outputs for more information See page 98 Safety The control panel is fitted with a fused terminal block for connection of a 230 volt AC mains supply This should only be connected by a qualified electrician Always observe electrical safety precautions See Fig 29 D3000 Series Installation Manual D3000 INST O9H v3 27 Proximity Readers The D3232 proximity reader comprises a controller housed in a plastic box and one or two tag readers The tag readers may be mounted externally to allow the system to be unset from outside the protected area and if appropriate unlock the entry door Up to 10 proximity readers may be connected to the bus on D3001 11 control panels and up to 2 may be connected to a D3021 22 The D3232 Proximity Reader is NOT compatible with the older D3000 and D3020 control panels The panel detects its presence and no further programming is required
25. is fully described later in this manual Refer to section power supplies and batteries D3000 Series Installation Manual D3000 INST O9H v3 41 ADD8PSU cont d LED Indicators The ADD8PSU is fitted with several LED indicators Each of the resettable fuses has a red LED to indicate when it has tripped See Fig 43 The ACTIVE LED will flash twice in two seconds to indicate normal operation If the LED is not on at all or flashing rapidly it indicates incorrect operation of the circuit board Contact Dycon for more information The REVERSE polarity battery LED will be lit if either or both batteries are incorrectly connected to the battery terminals Reset The RESET pins reset the microprocessor in the ADD8PSU Use of this pin with the DEFAULT pin will partially or fully delete all programming and return all parameters to the factory default values See Fig 43 ADOD8PSU Internals Fig 44 ADD8PSU Internals Fig 45 D3000 Series Installation Manual D3000 INST O9H v3 42 ADD8PSU cont d Engineers Keypad A socket is provided so that an Engineers Keypad can be plugged in the circuit board while in the Engineering Mode D3001 and D3011 only See Fig 43 Bus Connection Always connect the Network IN A B C amp D terminals towards the Control Panel Always connect the Network OUT A B C amp D terminals away from the Control Panel See Fig 44 and 45 This applies to each ADD8PSU no matter how
26. operate but all other functions are powered from the exchange equipment It is important therefore to connect the Control Panel to the left hand analogue telephone socket on the NTE9 See Fig 79 A maximum of two calls on an NTE9 may be in progress at the same time Use of one analogue telephone socket constitutes one call Use of the S bus on either S bus socket constitutes one or two calls 64 or 128 K byte bandwidth If two calls are in progress it is impossible to make another outgoing call or receive another incoming call The two call maximum means that if either of the S bus sockets are being used and a telephone call is in progress on one analogue socket then anybody ringing into the other analogue telephone socket will get a busy signal Equally any connection to the other analogue socket e g the control panel will not hear the dialling tone and will not be able to dial out Note that an over ride line grab facility does not exist on an NTE9 Refer also to the Safety Earth and the Call Minder sections Control Panel Duaicom Digicom or other Home Highway Termination Paint NTP ISDN2 Home amp Business Highway Fig 79 ISDN30 Integrated System Digital Network 30 channel A primary rate ISDN line can carry the equivalent of up to thirty simultaneous calls In UK a primary rate ISDN line is called ISDN30 This is a digital telephone line that conforms to the international ISDN s
27. position for the aerial This will be at the point of strongest signal ensuring that it is within the protected area This is usually the highest point in the building and well away from metal roofs metal walls and sources of radio interference Refer to sections for Plug on VDN or GSM Radio Modem and Appendix 1 Call a help desk and ask for a radio signal strength prediction See page 14 For this you will need to know which radio network will be used and have the postcode of the site available This will tell you if there is radio coverage at the proposed site and the signal strength that can be expected If there is no radio coverage at the proposed site the radio alarm reporting path using that radio network will not operate Another radio network may provide better signal strength Ensure that the aerial lead will be long enough to reach to the control panel The control panel can be mounted anywhere within the protected premises apart from the entry route Remember it is always easier to find the point of strongest signal for the aerial before the equipment is fitted to a wall Moving aerials cables trunking etc after installation is wasted time and effort 2 PSTN Telephone line Where telephone line communications will be used with your alarm system as part of the dual signalling select a suitable network termination point If one requires fitting request a telephone network provider to install a line and termination at that point Ref
28. the lid from the case back by sliding the lid to the left so that the hinge uncouples See Fig 31 Mark the position of the selected case mounting holes Drill the wall Break out the selected cable entry point s then mount the case ensuring that it is level When the keypad case is closed there is not much internal space for wiring therefore it is strongly recommended that the suggested wiring plan is followed See Fig 31 D3000 Series Installation Manual D3000 INST O9H v3 30 Keypads cont d 1 Lift transparent 2 Remove Screw 3 Prise lid open here plastic cover here OO O O mom Fig 32 When the cables have been brought into the case the outer sleeve of cables should be removed where they enter the case Inside the case cables should avoid crossing each other because this adds to their thickness Always tie wrap cables to the central cable guides before connecting them to the terminals See Fig 31 Refit the lid to the back by sliding the hinge parts together The lid will now hang down with its face to the wall so that connections may be made to the terminals The various connections are described later in this manual Refer Table 18 below Subject Page Number System Bus Wiring 90 Audio Bus 97 Zone Inputs 98 Internal Sounders 101 Programmable Outputs 104 Auxiliary Power Outputs 109 Table 18 Rear of Case TOA Tamper Switch Wall a Screw fitted in Vall Circ
29. the test button for that channel When system testing is complete refit the case lid ensure that no wires are trapped between the back and lid or trapped around the tamper switch Refit the 2 lid securing screws Note The lid will fit either way round but the screws will only fit with the lid the correct way round Do not use longer screws than those provided when securing the lid to avoid damage to the case Aerial m TN sreak oute Catch to release board Rear Tamper Stich adjustment Screw Cach ta eleese board E i Aresk ouls Fig 69 Long range 4 channel transmitter D3000 Series Installation Manual D3000 INST O9H v3 63 Wire free Detectors cont d D4820 Long Range 4 Channel Transmitter cont d Tamper Switches The case includes 2 tamper switches The one with a spring fitted is a lid tamper switch only The case back tamper switch is operated by an activation lever moulded into the aan rear of the case This lever holds the switch in its closed position See Fig 70 Wall Rear of Case Back Tamper Switch TS i Tamper Ach usiment Screw Aerial Options Board The 4 channel transmitter may be used with the D4830 quarter wave aerial the D4831 dipole and 5m coax lead Side view of Tamper Switch or the D4832 Yagi aerial and 5m coax lead To adjust loosen the case mounting screws then turn the back tamper screw further into or out of the wall until it ope
30. too low you can then add power supplies or install additional cables A more professional method is to calculate the expected voltage drop so that you can install the necessary power supplies and cables at one time To calculate the voltage drop you will need to know the current that is being drawn the length and resistance of the wire used The current can be estimated by adding up the current requirement from the specifications of each item that receives its power via cables Distance requires a tape measure Refer to Appendix 4 for a table of currents consumed by each item in the D3000 range Two methods of calculating voltage drop follow and if it is too high two methods of reducing it to acceptable levels are described D3000 Series Installation Manual D3000 INST 09H v3 77 System Bus Wiring cont d Method 1 Use the table If you are using normal 7 020 low voltage alarm style wiring you can use this table to estimate the voltage drop along wires This table is for single cores of 7 020 wire Normal 7 020 alarm wiring has 8 ohms resistance per core per 100 metres Example Refer to Fig 103 Distance between the power supply and the first ADD is 50 metres The current flowing along this section of wiring 275mA Look on Table 42 at the 250mA and 300mA line at 50 metres distance 275mA is halfway between 250mA and 300mA Therefore the voltage drop will be about half way between the two voltage drops shown i e 2 20 volt
31. 0116 RS Part Number 472 534 The installer must ensure that 1 The user s telephone wiring is disconnected from the NTP and reconnected to the D0730 ADSL filter only 2 The NTP connects only to the D0730 ADSL Filter and to no other wiring or telephone sockets 3 The wiring between the NTP and the D0730 ADSL filter cannot be unplugged by the user 4 The user cannot plug a telephone fax etc into the NTP 5 The terminals 2 3 and 5 A and B and A1 and B1 are connected exactly as shown Analogue amp ADSL service provkied ADSL Filter amp security equipment by the Network Sendoa Provider In a temper protected enclosure E TE T Network Tarmination Poirt NTP 3 Telephone Exchange 5 Phone or Fex Socket Piug in ADSL filter i A When ADSL broadband digital data is supplied on a normal PSTN telephone line an ADSL broadband filter must be fitted between that telephone line and each item of non digital equipment because the operation of non digital equipment may be disrupted or completely inhibited if ADSL broadband digital data is allowed into it from the telephone line PSTN Connection using a Master Socket amp the D0730 Security ADSL Filter Fig 82 Q Why is a broadband filter necessary Non digital equipment means anything that would be used on a normal analogue PSTN telephone line i e a telephone Fax machine Dualcom Digicom digital communicator control panel s Digi
32. 25 C The power supply in all control panels and ADD8PSU is a switched mode design which generates very little heat This all helps to keep the heat in the metal case to a minimum To avoid premature battery failure it is recommended that the control panel and ADD8PSUs are installed in areas that avoid very high temperatures e g boiler rooms Temperature Compensation l Temperature Battery All lead acid gel batteries require a particular charging voltage to Centigrade Charging ensure that they are fully charged but not overcharged Overcharging Voltage can destroy batteries in a few weeks in extreme cases This optimum voltage changes with temperature The D3001 11 control panel a ieee and ADD8PSU power supplies are temperature compensated so that the output voltage always achieves the optimum battery charging Ag 13 99 voltage 100mV for their standby batteries This will extend the working life of batteries See table 48 30 13 50 20 13 70 10 14 00 Table 48 0 14 30 D3000 Series Installation Manual D3000 INST O9H v3 89 Power Supplies and Batteries cont d Battery Presence Detection All control panels and ADD8PSUs continuously check for the presence of a battery This is to ensure that a battery is connected when the engineering mode is terminated This feature will also detect a battery that has completely failed or lost the majority of its charge capacity Battery Deep Discharge P
33. 3000 Series Installation Manual D3000 INST O9H v3 Weak signal radiated or received in all other directions Maximum signal only radiated or received inthis direction 4 Channel Transmitter or ADD RADIO Yagi Aerial Fig X3 3 97 Maximum Maximum Typical Receiver range 8m range 1 5m range in Transmitter Receiver z above open above open building Note Aerial ground ground metres metres metres D4810 PIR Movement Quarter Wave Detector D420 OVADDAM Vertical Aerial 1090 Sog 99 4 Vertical Dipole 700 250 50 Reception from one Vertical Yagi 1500 450 120 direction only D4811 Door Contact 7 a Quarter Wave Universal Transmitter D4220 or ADD R Vertical Aerial 1000 300 80 j 5 Vertical Dipole 700 250 50 Reception from one Vertical Yagi 1500 450 120 direction only D4812 Handheld Quarter Wave Controller D4220 or ADDR Vertical Aerial one 200 2 7 i Vertical Dipole 200 150 40 Reception i from one Vertical Yagi 450 300 70 direction only D4814 Smoke Quarter Wave Detector D4220 or ADDER Vertical Aerial 500 a09 3 y 2 Vertical Dipole 350 200 40 Reception m i y from one Vertical Yagi 750 450 80 direction only Quarter Wave D4815 Water Detector D4220 or ADD R Vertical Aerial 500 300 50 4 Vertical Dipole 350 200 40 Reception 7 i a i from one Vertical Yagi 750 450 80 direction only D4816 Long Range Quarter Wave N
34. A ota ee along this section of wiring 275mA oF cc J Distance between first ADD and the keypad SY e D a SERA a ert is 20 tlle The oe ee this section of wiring mA See Fi 100mA aed Fig 89 D3000 Series Installation Manual D3000 INST O9H v3 78 System Bus Wiring cont d Method 2 Calculation This works for any type of cable 1 Measure the wiring length between two points in metres Call this value D 2 Determine the current that will be flowing between these two points in Milliamps 1000 Milliamps 1 Amp Call this value C 3 Determine the resistance of 100 metres of the wire used in ohms Call this value R 4 Multiply D by C then multiply by R Divide the result by 50 000 This is the voltage drop between those two points 5 Repeat this along the whole length of the bus wiring Example Refer to Fig 90 Distance between the power supply and the first device is 50 metres The current flowing along this section of wiring 275mA The wire on the A and B connections is single core 7 020 alarm wiring which has 8 ohms per core per 100 metres 50 x 275 x 8 110000 110000 50000 2 2 Therefore the voltage drop is 2 2 volts If the power supply output is 13 6 volts the voltage at the A and B terminals at the first device will be 13 6 2 20 11 40 volts Use the table or calculation method for every length of wiring between ADDs keypads and the control panel If the voltage at any output is calculated
35. ARC and to receive checking and acknowledgement replies from that receiving equipment The Contact ID protocol is commonly used in burglar or intrusion alarm equipment See also DCID Digital CONTACT ID Digital Contact Identification An alarm reporting protocol of data used to send via an analogue PSTN telephone network or a digital data network e g VDN GSM data a transmission to receiving equipment at an ARC and to receive checking and acknowledgement replies from that receiving equipment D3000 Series Installation Manual D3000 INST O9H v3 106 APPENDIX 7 cont d Glossary of Terms cont d Digital PSTN Digital Public Switched Telephone Network The digital national telephone system Service is available to customers on twisted pair wires that carry a DC supply provided from the network telephone exchange on optical fibre or other digital transmission medium The digital service may be in ISDN format or another digital format Digital SIA Digital SIA An serial alarm reporting protocol of data used to send via an analogue PSTN telephone network or a digital data network e g VDN GSM data a transmission to receiving equipment at an ARC and to receive checking and acknowledgement replies from that receiving equipment DTMF Dual Tone Multi Frequency The series of tones used by telephones to send dialling information to an analogue PSTN exchange These tones are also used by the DTMF Fast Format alarms reportin
36. D3021 and D3022 control panels are for smaller systems They include a 1 2 Amp power supply Up to 8 detectors may be connected on FSL loops directly to each control panel board In addition there are 4 fully programmable outputs one with relay contacts 3 outputs on the D3021 22 Each control panel has an output for an internal sounder plus outputs for external sirens bells and strobes There are three fused 12 volts output to power the detectors and other devices 2 outputs on the D3021 22 All control panels have an on board Digi Modem All control panels can be fitted with the CS1070 plug on VDN radio modem for VDN radio communications or the D2070 plug on GSM radio modem for GSM radio communications All control panels can be fitted with the D3024 output board when other alarm reporting networks are required All control panels can be expanded using units that connect to the 4 wire bus The D3001 and D3011 monitor up to 10 keypads 10 proximity readers 13 ADD8s or ADD8PSUs and 8 ADD Rs A fully expanded D3001 and D3011 system has 144 FSL inputs 72 fully programmable outputs 26 internal sounders and 64 wire free detectors Refer to the tables on page 4 The D3021 monitors up to 3 keypads 2 proximity readers 2 Add8s and 2 Add Rs A fully expanded D3021 system has 36 FSL inputs 16 fully programmable outputs 6 internal sounders and 16 wire free detectors Refer to the tables on page 4 The D3022 monitors up to 3 keypads 2 proxim
37. GSM In addition the programming PC or laptop can be connected by a serial lead directly to the control panel D3000 Series Installation Manual D3000 INST O9H v3 3 System architecture All control panels may be set for commercial or domestic use All systems may be programmed in the same manner All engineering programming at the keypads is accessed by menus Any menu may be selected by a short cut code of one letter and 2 numbers Copy and paste functions allow many zones groups and outputs to be selected and programmed in a short time Refer to the table on the next page for details of each system s expansion options The D3001 11 Control Panels The D3001 11 has up to 208 zone inputs Each is associated with 1 of up to 20 groups Groups may be set and unset using operator codes and or proximity tags cards There are up to 68 operator codes and prox tags these incorporate users and engineers Each operator code can be associated with any or all of the 20 groups Fast setting and unsetting of a particular selection of groups is possible for each of the operator codes Operator codes can have different attributes for use as managers users cleaners etc Each keypad can be associated with any or all of the 20 groups Each group has its own bell timers which control the operation of the bell s for that group These timers are used by the group when the system is not full set When the system is full set when each group that
38. If the PSTN line used by the control panel is shared with other apparatus e g telephone fax or answer machine connect the control panel s telephone line terminals marked A1 and B1 to a PSTN Socket Terminals 1 and 6 in the NTP can be used as loop in points for this purpose The customer may then plug their phone fax etc into that socket See Fig 88 A PSTN master socket type LUU2 4A is suitable and has screw terminals for connection These can be obtained from many electrical distributors including CPC Part Number TE 00666 Farnell Part Number 916 638 Maplin Part Number FT48C Rapid Part Number 24 0116 RS Part Number 472 534 4 The D3000 Series range of control panels do not require a telephone earth connection Digi Modem A B AIB Fig 74 Fig 75 D3000 Series Installation Manual D3000 INST O9H v3 68 PABX Private Automatic Branch Exchange A PABX is a telephone exchange in one business or building where a dial 9 is needed for an outside line It connects to one or more outside telephone lines and has two or more extensions within the business or building See Fig 76 The control panel may be connected to one of the outside telephone lines where they are the analogue PSTN type The control panel cannot be directly connected to a digital telephone line See Fig 77 The extensions within the building may be analogue or digital Where an extension is analogue then a normal phone or fax m
39. Manual D3000 INST O9H v3 46 ADD R cont d Engineers Keypad A socket is provided so that an engineer s keypad can be plugged in the circuit board while in the engineering mode D3001 and D3011 only See Fig 48 Power Consumption The bus supply must be 10 volts or greater Refer to Appendix 4 for the current consumption of all units Use these figures when calculating the voltage drop along bus wiring and when calculating battery capacities Note that there are no auxiliary 12 volt outputs on an ADD R Surveying An ADD R and 12 volt battery can be used to survey a site for placement of short range detectors This is described in Appendix 3 When surveying the red 4 and green 4 received signal strength LEDs 4 will remain lit after each radio transmission Press the rear tamper switch to reset them ready for the next test transmission Safety When closing the case ensure that no wires are trapped between the back and lid or trapped around the tamper switch Refit the 2 lid securing screws Note The lid will fit either way round but the screws will only fit with the lid the correct way round Do not use longer screws than those provided when securing the lid to avoid damage to the case D3000 Series Installation Manual D3000 INST O9H v3 47 Plug on GSM Radio Modem Aeriallead CS2070GSM Push button to eject Radio Modem SIMCard slot SIM Card Fig 49 Installation Disconnect both Mains and batte
40. R plus a 12 volt battery and the supplied aerial be used in conjunction with a D4812 hand held controller The hand held controller has got the least range of all the radio devices and if reception can be confirmed using this item then reliable communication with other wire free detectors is to be expected Surveying Methods When surveying the ADD R and 12 volt battery can be placed temporarily in the chosen location s and likewise the wire free detectors or hand held controller placed temporarily in their chosen positions Note that the red and green LED4 received signal strength LEDs on the ADD R will remain lit after each radio transmission Press the rear tamper switch to reset them ready for the next test transmission A reliable received signal strength should be in the average or high area Signal strengths can also be displayed on an installed control panel and ADD R system With the control panel in the RSS display mode press the test buttons on the wire free detectors or activation buttons on the portable transmitters to generate test transmissions Note the RSS level indication to make sure that the transmitter will operate reliably the signal strength should be strength 2 or greater Where long range links using directional Yagi aerial s are surveyed make sure that the wire free detectors to be used are learnt in at short range before testing Care has to be taken when testing long range links using directional Yagi aerial
41. STN The network is usually provided as a 2 channel or 30 channel ISDN service ISDN 2 2 Channel ISDN An ISDN communication service where two simultaneous channels may be used Each channel is normally a 64 KB sec serial data path Each path may typically carry one speech telephone call or an internet connection or a fax call ISDN 30 30 Channel ISDN An ISDN communication service where thirty simultaneous channels may be used Each channel is normally a 64 KB sec serial data path Each path may typically carry one speech telephone call or an internet connection or a fax call NTP Network Termination Point A telephone line is terminated at the user s premises by a Network Termination Point which is provided by the Telecomms Service Provider This is a socket or connection where the user s equipment can be connected NVM Non Volatile Memory An integrated circuit memory device that does not need any power to remember data PABX Private Automatic Branch Exchange A small telephone exchange for use within one building or group of buildings Commonly used in businesses where each phone in that business is an extension on that PABX Usually connects to one or more analogue PSTN or ISDN telephone lines PSTN Public Switched Telephone Network A national telephone system This may be analogue and or digital See analogue PSTN SAB Self Activating Bell SAB refers to the type of control circuits in a bell siren unit The unit incl
42. See Fig 53 2 The yellow Active LED will flash slowly for 20 seconds During this period the GSM radio modem will test communications with all GSM base stations that are within range it will then lock onto the best signal and obtain its operational parameters from the GSM network 3 After 20 seconds the yellow Active LED should remain on without flashing This indicates that it has locked onto a signal from a base station The red and green signal strength LEDs will then show the strength of the received radio signal See table on next page If the signal strength is Low or None then the aerial is not located where it can pick up a working signal and alarm reporting via the GSM network will not be possible The aerial must be moved to a position where a working signal can be received Refer to page 87 for aerial siting details Plug on GSM Radio Modem Location ona D3021 D3022 Control Panel Fig 52 D3000 Series Installation Manual D3000 INST O9H v3 49 Plug on GSM Radio Modem cont d LED Indications LEDs Indication Meaning Active Yellow Flash Registering 20 sec Reporting and up downloading will not operate i On solid Signal from base station being received 2 flashes pause Panel unable to communicate correctly with GSM radio modem OK Green amp Low Red _ OK On Low Off A strong GSM radio signal is being received Very good OK On Low On An average GSM radio signal is being rec
43. able 2 on page 7 D3000 Series Installation Manual D3000 INST O9H v3 54 D4810 PIR Wire free Detector Manufacture marking IR 8L Installation 1 Ensure that the location chosen for this item and the location s of the receiver s will provide a sufficiently strong radio signal to be received Refer to Appendix 3 Wire free Detectors 2 Loosen the single screw on the lower end of the PIR detector and remove the back plate 3 Fit the batteries in their holder Refer to Appendix 3 Batteries 4 Fit the test Jumper in the test position 5 Learn in the PIR movement detector to the control panel by pressing the test button 6 Select the mounting position so that the PIR is overlooking the required area See Detection Coverage below Check operation with the LED 7 Using that position mount the PIR back plate using the screws provided Where back tamper detection is required drill out the access hole and fit a screw in the wall so that it enters the back plate and operates the tamper switch when the PIR detector is fitted to the back plate 8 Fit the PIR detector onto its back plate and secure with its single screw 9 When system testing is complete open the unit and put the test jumper in the normal position Tr Ti i Test Button mae QO Lens 0o Tamper Switch i eee Fixing Screw and Spring N Test Jumper PIR Controls Yi I PIR Wirefree Detector Fig 59 Fig 60 Learning in The PIR is le
44. achine may be connected The control panel can be connected here and programmed to dial a 9 When this connection option is used note that downloading to the control panel may not be possible via the telephone line Where the extension is digital then it is often to the ISDN standard or is a special digital standard that is particular to the manufacturer of the PABX equipment Where a special digital standard is used a special feature phone is usually required provided by the manufacturer of the PABX equipment The control panel cannot be directly connected to any type of digital telephone line PABX with connection to Analogue PSTN Line Fig 76 Control Panel Duaicom Digicom or other analogue tnlaphone PABX Private Automatic Analogue or Digital PSTN service provided equipment Branch Exchange by the Network Service Provider One or more Analogue or Digital fines PABX with Analogue extention Fig 77 D3000 Series Installation Manual D3000 INST O9H v3 69 ISDN Integrated System Digital Network The digital ISDN is a communication network where the line from the exchange equipment and the service supplied to the subscriber is digital i e not analogue An ISDN line is a digital telephone line that conforms to the international ISDN standard It can carry several calls simultaneously Two types are generally available Refer to Table 35 ISDN Type Name Number of simultaneous ca
45. al The optional dipole aerial and 5 metres of coax cable may replace the quarter wave aerial The range will be less with the dipole typically 3 4 of the range with the quarter wave aerial The dipole aerial must be positioned vertical straight up down The dipole should only be used in preference to the quarter wave when the aerial must be in a particular location and the ADD R cannot be at the same point and a lower signal strength is acceptable Reception will be from any direction not directly above or below Yagi Aerial The optional Yagi aerial and 5 metres of coax cable may replace the quarter wave aerial The range with the Yagi aerial will be approximately 2 to 3 times greater than with the quarter wave aerial The Yagi aerial must be positioned vertical straight up down when used with any wire free detector that has a vertical aerial When the Yagi aerial is used with the 4 channel transmitter that has its own Yagi aerial then both aerials must be both horizontal or both vertical The Yagi aerial should only be used in preference to the quarter wave when an increase in range or signal strength is required and it is acceptable that transmission or reception will be in one direction only Aerial Direction Patterns Equal signal radiated inall mr Detector Any Wirefree Detector Top View Fig X3 1 Equal signal received from all ws ADD R with vertical Quarter Wave or Dipole Aerial Top View Fig X3 2 D
46. al See diagram for connection details Connect an internal sounder to the sounder terminals Connect a SAB bell siren and strobe to the bell and strobe terminals Connect a 12 volt lead acid gel battery Connect a mains supply or operate on battery only by shorting the Kick Start On pins The basic system is ready to operate Test the system by setting causing an alarm unsetting the system A full list of the Factory Default Values are shown in the programming manual The basic values are Panel Type Commercial Level 2 User Code 1 2 3 4 OK User Code Level 3 User Code 7 8 9 0 OK Engineer Code Exit Mode Final Door Set Entry Exit Timer 10 seconds Bell Delay 0 seconds Bell Timer 10 minutes Zone 1 FSL Final Door Zone 2 FSL Entry Exit Route Zone 3 to 8 FSL Normal Night Zone Tamper inputs Closed Circuit Zones 1 8 In Group 1 Group 2 20 Unused Rearms 3 D3000 Series Installation Manual D3000 INST 09H v3 102 APPENDIX 4 cont d Setting up a Basic System Control Panel 1 Keypad cont d AC Input Reverse Polanty Battery LED Aux 1 Output amp Fuse LED Battery Connectors Intemal SounderFuse LED Extema Sounder Fuse LED Power Supply Kick Start amp DO NOT Stop on off REMOVE Pins COVER SAB Bell Strobe Mains Supply amp 12v LEDs Overvoltage Waming LEDs Wire Links Aux 2 Output amp Fuse LED Active LED Normal Night Zone 3 Zone4 Network 1 TERM jumper
47. al Sounder Tripped Fuse LED Engineers for Siren Bell Siren Bell amp Strobe terminals E Tamper zi Switch Tripped Fuse LED e Shunt pins for Aux 2 O P L 9 is Zone 1 4 Inputs _____ 9 2 a Bus terminals al TERM NETWORK IN S umper link Tripped Fuse we Active LED for Bus Power 7 r Bus terminals S Bus Address NETWORK OUT 3 Selector Switch amp z Jumper Link Tripped Fuse L j for Aux 3 O P Factory Service Zone 5 8 Inputs ADD8 amp PSU Circuit Board Connector Fig 43 Termination If the ADD8PSU is connected at one of the ends of the bus a jumper link must be fitted to the TERM pins If the ADD8PSU is connected at any other position on the bus a jumper link must not be fitted to the TERM pins When the TERM jumper is not used park it on one of the two pins See section on bus wiring for further information on addressing Shunting the Tamper Switch s The SHUNT selector will bypass the tamper circuit Remove the jumper link or park it on one of the two pins for normal tamper switch operation Fit the jumper link to the two pins for ADD8PSU operation with the lid open Closing the lid with the shunt link in the shunted position will stop an exit from engineering mode and a warning message will be displayed on keypads Kick Start The KICKSTART pins will switch the control panel On or Off when running on batteries only mains disconnected See Fig 43 Their operation
48. and held controller When the On Off switch is in the ON position the LED will flash once when any of the 4 buttons are pressed Radio Transmissions The unit will not operate when the On Off switch is in the OFF position The radio transmitter in the unit will send the following signals A separate alarm signal from each of its 4 buttons A B C and D There is no restore signal when the buttons are released There is no tamper signals from this unit There is no supervisory signal from this unit There is no low battery signal from this unit Refer to Appendix 3 Transmission Details Range Expectations Refer to Appendix 3 Range Expectations Battery Replacement There is no low battery signal transmitted by the hand held controller As the battery voltage falls so the range of operation will fall Replace the battery in this unit when the range becomes insufficient Refer to Appendix 3 Batteries D3000 Series Installation Manual D3000 INST O9H v3 59 Wire free Detectors cont d D4814 Smoke Detector Manufacture marking SD 8L Installation 1 Ensure that the location chosen for this item and the location s of the receiver s will provide a sufficiently strong radio signal to be received Refer to Appendix 3 Wire free Detectors Rotate anti clockwise and remove the back plate from the rear of the smoke detector Fit the 4 batteries in their holder Refer to Appendix 3 Batteries Wait for approximately 15 m
49. arnt in to the control panel by pressing the test button The test button can also be used to test the device when the display test mode Test Jumper Put the jumper in the test position to enable the LED and shorten the sleep time Put this jumper in the normal position to disable the LED and set the sleep time to 1 minute With the jumper in the test position the LED will flash every time the unit transmits This can assist the alignment of the PIR s pattern and range Also the sleep time is shortened from 1 minute to about three seconds When testing is completed the test jumper should be put in the normal position so that the battery life is not reduced and the units operation is not obvious to an observer PIR Sleep Time Sleep time will conserve power and extend the unit s battery life During the sleep time radio transmissions are inhibited The PIR sleep time is set at 1 minute when the test jumper is in the normal position The sleep time is re triggerable and any movement that is detected during the sleep time will extend the sleep period by 1 more minute Thus continuous movement in an area will not cause continuous radio transmissions D3000 Series Installation Manual D3000 INST 09H v3 55 Wire free Detectors cont d D4810 Wire free PIR Detector Wire free D4809 Pet tolerant PIR Detector PIR LED There is a red LED that shines through the PIR white lens This LED will indicate tamper and low battery co
50. as access to menu option 9 engineer s menu VDN Vodafone Data Network Paknet A private X25 communication system operated by Vodafone in UK for users that are not mobile for carrying digital data not speech where the path from the user is by a radio link to one or more fixed site s 3 Way Calling This is a service provided by some telecommunication service providers BT in the UK offer this service When a call is in progress on a telephone line it is possible to send a signal via that line to the equipment at the telephone exchange The exchange will put the current call on hold and provide a dialling tone so that another outgoing call may be made When this second call has finished a signal to the exchange will disconnect the second call and re connect the first one that was put on hold D3000 Series Installation Manual D3000 INST O9H v3 109
51. ay Dycon Installation Manual for the D3001 D3011 D3021 D3022 EN Compliant CIE CIE v5 Software or later ACE v2 Software or later These products are suitable for use in systems designed to comply with PD6662 2004 and EN50131 1 D3001 Grade 3 Environmental Class Il D3011 Grade 3 Environmental Class II D3021 Grade 2 Environmental Class II D3022 Grade 3 Environmental Class II Dycon Ltd Tel 44 0 1443 471060 Fax 44 0 1443 479374 www dyconsecurity com info dyconsecurity com INDEX Introduction System Architecture Part Numbers and Pictures What to Do READ THIS System Planning and Design Site Survey Installation System Testing Factory Defaults and Resetting Help Desk Frequently Asked Questions The Details Control Panels D3001 3011 3021 D3022 Proximity Readers D3232 Keypads D3202 B D3205 D3211 B D3212 B ADD8 D3300 ADD8PSU D3500 D3510 ADD R D3301 Plug on GSM Radio Modem D2070 Plug on Output Board D3024 Plug on Audio Module D3025 Wire free Detectors D4809 D4810 D4811 D4812 D4814 D4815 D4820 Telephone Line Connections PSTN Digi Modem Analogue Telephone Line Connection Options PABX ISDN ISDN2 ISDN30 Home Highway Business Highway ADSL Broadband The Call Minder call answering service Safety Earth connection System Bus Wiring Audio Bus Wiring Wired Zone Inputs Wired Tamper Inputs Internal Sounders Siren Bell and Strobe Connections Program
52. be received If there are no signals received within 20 minutes from any individual radio device the control panel may output a radio fault Where no signals are received for 2 hours then the control panel may output a radio tamper Battery Life and Replacement Battery life in all devices is dependent upon their usage In normal domestic situations a battery life of 2 years or greater can be expected from all units Refer to Table X3 2 All wire free detectors will transmit a low battery signal to the control panel This signal will be sent before the batteries are fully discharged and the detector operation ceases It is important therefore to replace batteries with good quality alkaline cells when the low battery warning if first transmitted This is especially important for the smoke detector There is no low battery signal transmitted by the hand held controller As the battery voltage falls so the range of operation will fall Replace the battery in this unit when the range becomes insufficient D3000 Series Installation Manual D3000 INST O9H v3 99 Wirefree Detectors cont d Transmitted Radio Signals Table X3 3 shows the radio transmissions and when they will be made for all of the wire free APPENDIX 2 cont d detectors A Low P Transmitter Detection Tamper Battery Supervision Test Learn In Note D4810 PIR Movement Detector D4809 Pet Infra Red Moveme
53. bus device A second set of connections are provided for onward connection along the bus AUDIO BUS These terminals route the audio bus along the network they are not connected to any circuitry VP Activating this input operates the relay to allow the use of an egress switch The input can be triggered by a positive or negative applied signal depending on the position of the I P link immediately above the connection This is a 12v auxiliary output for powering devices such as a holding magnet or door strike CNC NO Common Normally Closed and Normally Open voltage free contacts for activating devices such as a holding magnet or door strike R1 BLK1 Y1 G1 BLU1 W1 Connections to tag reader 1 The cable on the tag reader is colour coded such that R Red BLK Black Y Yellow G Green BLU Blue and W White R2 BLK2 Y2 G2 BLU2 W2 Connections to tag reader 2 with the same colour coding as above When tag reader 2 is used the link marked RDR2 must be fitted ENG KEYPAD This socket is used to connect an engineer s keypad to provide full system control Links DOOR ENTRY The proximity reader provides door entry functions Presenting a tag when set will unset the system and unlock the door Subsequent tags will merely unlock the door To set the system present the tag and hold it in place for 5 seconds RDR2 This link must be fitted if a second tag reader is to be used STAND ALONE This link must not be fitted if th
54. can detect 2 states These are normal no detection and detection tamper FSL Fully Supervised Loop A two wire connection between an alarm system and a detection device Three resistors are fitted to the loop at the detector together with switches The detector changes the state of the switches to signal that it has detected something The alarm system measures the resistance of the loop and can detect 5 states These are Normal 2K2 Fault Masked 4K4 Active 6K9 Masked 9K1 and Tamper open or short circuit NOTE to monitor for fault and masked conditions the CIE must be fitted with software version 5 000 or later and all ACE must be fitted with software version 2 00 or later D3000 Series Installation Manual D3000 INST O9H v3 107 APPENDIX 7 cont d Glossary of Terms cont d GSM Global System for Mobile Communications Digital telephone service particularly but not exclusively for users that may be mobile for carrying digital data speech or fax where the path from the user is by a radio link to one or more fixed sites Hybrid Line A line that carries digital data and analogue signals simultaneously Most commonly this is an ADSL digital service and an analogue telephone service on one line from a Service Provider to a subscriber ISDN Integrated Services Digital Network A digital communication network where services are provided via electrical or optical cables This may also be a digital P
55. circuit board by releasing the two white plastic catches Remove the circuit board from the case See Fig 69 Mark the position of the selected case mounting holes Drill the wall Break out the selected cable entry point s then mount the case When used with the Quarter wave aerial ensure that the aerial is vertical straight up or down The break outs on the ends of the case may be opened by inserting a terminal screwdriver into the slot at the end of the knock out and twisting Re install the circuit board in the case Replace the securing screw Connect the aerial to the aerial socket The aerial must be vertical Connect the DC supply to the power terminals 11 15 volts Where cables have been brought into the case the outer sleeve of cables should be removed where they enter the case Always tie wrap cables to the cable guides before connecting them to the terminals Ensure that any wiring is lead away from the circuit board and the aerial With wiring close 10cm to the erial then a reduction in radio range should be expected Connect normally closed loops and switches to each of the Z1 to Z4 input terminals Check operation with the LED Where external tamper detection is required connect a normally closed loop to the A T tamper terminals When unused link terminals together Adjust the back tamper screw for correct operation See Fig 70 Learn in each channel of the 4 channel transmitter to the control panel by pressing
56. ct Universal Detector Transmitter F ft Fig 18 D3090 Bus Expander Fig 19 D4830 Quarter Wave Fig 20 D4832 Yagi Aerial Aerial supplied with D3301 Fig 21 D3205 Engineer s Keypad Fig 22 D4831 Half Wave Dipole Aerial Fig 23 D3510 ADDSPSU D3000 Series Installation Manual D3000 INST O9H v3 8 System Planning and Design Groups and Quick Set Keys Although most items can be programmed in any order and at any time during installation or at a later time it is important to program some items before others This is essential when programming group features and the operation of the Quick Set keys Program these items in this order 1 Planning Plan the operation of the alarm system and decide how many groups are required and how they will be used Refer to System Description and Architecture on pages 3 and 4 Decide the location and wiring routes for all keypads ADD8 ADD8PSUs ADD Rs and the control panel with its radio and telephone modems 2 The System Type Select domestic or commercial Mode Refer to System Architecture on page 4 and menu C01 in the Programming Manual 3 Zones Select one or more zones and associate them with the groups required A group will be unused if no zones have been associated with it Ensure that all of the planned groups have one or more zones associated with them For each used zone select that zone s attributes e g Entry Exit Door 24 Hour Zone names and oth
57. d line Alarm Abort A facility to reduce false alarms requiring police response Specified by ACPO the Association of Chief Police Officers in UK An alarm abort situation occurs when the alarm system is set and an alarm occurs and then it is reset by the alarm system being unset by a key or valid user code all within 90 seconds This false alarm is often caused by the user of an alarm system failing to set the system correctly The alarm abort signal identifies this situation to the ARC thus avoiding an unnecessary police visit to the site Analogue PSTN Analogue Public Switched Telephone Network The analogue national telephone system Often just called the PSTN Service is available to customers on twisted pair wires that carry a DC supply provided from the network telephone exchange ARC Alarm Receiving Centre A 24 hour manned centre often privately owned and operated capable of receiving and logging calls of alarm and forwarding them to security authorities and other relevant services Often called a Central Station ARS Alarm Receiving Station See ARC Broadband See ADSL Call Minder A call answering service offered by some telecomm Service Providers where an incoming call to the subscriber s telephone is not answered Central Station See ARS CONTACT ID Contact Identification An alarm reporting protocol of DTMF tones used to send via an analogue PSTN telephone network a transmission to receiving equipment at an
58. e back tamper detection is required drill out the Access hole and fit a screw in the wall so that it enters the back plate and operates the tamper switch when the PIR detector is fitted to the back plate 8 Fit the PIR detector onto its back plate and secure with its single screw 9 Walk test the detector to confirm the detection pattern and range 10 When system testing is complete open the unit and put the test jumper in the Normal position Identifying parts 1 Test Button aka LED indicator It is the test button and also doubles as the LED indicator The test button is used for testing the radio performance and for learning purpose The LED indicator is used to indicate the status of system 2 Tamper Switch The Tamper switch protects the enclosure from being opened 3 Battery Insulator 4 Corner mounting bracket Learning in Fig 58 The PIR is learnt in to the receiver or control panel by pressing the test button The test button can also be used to test the device when used with a D4220 receiver that is in the RSS display test mode Test jumper Put the jumper in the test position to enable the LED and shorten the sleep time Put this jumper in the normal position to disable the LED and set the Sleep Time to 1 minute When testing is completed the test jumper should be put in the normal position so that the battery life is not reduced and the unit s operation is not obvious to an observer D3000 Series I
59. e 4 cores is needed for the bus wiring plus another 2 cores if the audio bus is to be used Screened cable can be used but this is not necessary Where the bus cable is long and or carrying power to several detectors keypads etc install a 6 or 8 core cable and use 2 or 3 cores for the A wire and 2 or 3 cores for the B wire This will reduce the voltage drop The ADD8 has a pot for volume control Can I control volume of the panel and keypads Yes Volume for loudspeakers connected to these devices is controlled via software Panel volume is controlled via Menu C03 0 off 16 full Keypad volume is controlled via Menu D80 where audio key bips status and loudspeaker volumes are independently controllable 1 min 7 max Do the panels have wire free detectors Yes via ADD Rs which are receiver modules which connect to the bus The D3001 control panel supports up to 64 wire free zones and the D3021 control panel supports up to 16 wire free zones these numbers being independent of the number of ADD Rs used The D3022 does NOT support wire free detectors So why have more than 1 Add R on a system On a simple system one ADD R would probably be sufficient In larger buildings however multiple ADD Rs allow the installer to ensure that good reception is available throughout the building or over very large sites The D3001 supports up to 8 ADD Rs whereas the D3021 supports up to 2 ADD Rs Why does the D3001 have a temperature measur
60. e and battery capacity for the specified standby time See pages 94 to 97 Any current that flows along wiring and the bus wiring to keypads ADD8s internal sounders detectors etc will cause a voltage drop Use these figures when calculating the total current flowing along each piece of wiring to ensure that the voltage drop is within limits See pages 79 to 85 Current Requirements Product Current Note D3001 Control panel 90 mA D3011 Control panel 90 mA D3021 and D3022 Control panel 100 mA D2070 Plug on GSM radio modem 70 mA D3024 Plug on output board 50mA D3025 Plug on audio board 50mA D3202 amp D3212 Keypads prox tags 55 mA All backlighting off D3202 amp D3212 Keypads prox tags 100 mA Backlighting on permanently D3202 amp D3212 Keypads prox tags 130 mA Keypad in use or reading a prox tag D3202 amp D3212 Keypads prox tags 300 mA Keypad in alarm D3211 Keypads 40 mA Backlighting off D3211 Keypads 60 mA Backlighting on permanently D3211 Keypads 90 mA Keypad in use D3211 Keypads 300 mA Keypad in alarm D3300 ADD8 30 mA D3301 ADD R 40 mA D3500 ADD8PSU 70 mA 16 ohm internal sounder 400 mA At maximum volume Typical value May rise to 1 External bell siren 50 mA Amp when active External strobe 200mA Typical value when active Typical value when fully Battery 7Ah 20mA charged May rise to 1 Amp when flat Typical value when fully Battery 17Ah 50
61. e different attributes for use as managers users Cleaners etc When set to commercial mode the D3021 22 are independent group setting control panels There are 4 groups that may be independently set and unset Each of its zones can only be associated with one group i e groups cannot overlap There are no Vari Zones Keypads can be associated with groups Bell siren and strobe outputs may be associated with each group Four Quick Set keys each allow each group to be set and unset When set to domestic mode the D3021 22 are part setting control panels There are 4 groups Groups cannot overlap Part set is where one or more of the 4 groups is not set when the control panel is set Any or all of the 48 zone inputs may be configured as a Vari Zone A Vari Zone belongs to each of the 4 groups and can have a different action in each group D3000 Series Installation Manual D3000 INST O9H v3 4 om LoCost 400 x 400 x115 2 LCD Ciephy pom fom om iai Disphy ot n Bachighting ves Yes Yes ms ugpedised Max FSL Inputs using D3201 or 03202 Multirrvedia Keypads Max FSL Inputs using D3211 or 03212 Lo Cost 16 ohm Sounder eutput e o i e e e aee o 8 8 400 300 4 400 Programmable 1TAmpe T Outputs 7 are w 4s Custom Output Tamexhour Types Femi a Proximity Readers eat pee i mc oe e fefe x33 Zones om DI000 ate Pasar on CS 1070 Zo p010 Passa __ z D T CAEN ep resis a ao
62. e free detectors no outputs ADD8PSU As ADD8 3amp power supply Case size 2 x 7Ah batteries ADD8PSU As ADD8 3amp power supply Case size 2 x 17Ah batteries or 4 x 7Ah batteries Wire free pet tolerant PIR 868MHz Use with ADD R Wire free PIR 868MHz Use with ADD R Wire free door contact 868MHz Use with ADD R Hand held controller 868MHz Use with ADD R Smoke detector 868MHz Use with ADD R Water detector 868MHz Use with ADD R Quarter wave aerial Supplied with ADD R Dipole aerial Optional aerial for use with ADD R Yagi aerial Optional aerial for use with ADD R Programming Software Programmer for up downloading and local connection Security ADSL filter For connection to ADSL Broadband PSTN telephone lines D3000 Series Installation Manual D3000 INST O9H v3 6 Fig 1 D3001 Control Panel Fig 2 D3011 ControlPanel D3240 Prox Tag Fig 5 D3202 MultiMedia Keypad plus Proximity Card Tagreader Fig 6 cs2070 Fig 7 D3232 External Proximity Tag Reader Plug on GSM Radio Modem Fig 8 03024 Plug on Output Board Fig 9 D3025 Plug on Audio Board D3000 Series Installation Manual D3000 INST O9H v3 7 Fig 11 04809 Wirefree Fig 12 D4810 Fig 13 D4812 Handheld Fig 10 p3301 app R PetTolerant PIR Wirefree PIR Controller if Fig 16 D4814 Smoke i i Detector Fig 17 D0730 Fig 14 D4811 Door Fig 15 D4815 Water Security ADSL Filter Conta
63. e installation Note that radio signals cannot pass through metal sheeting e g on warehouse buildings When installing wire free transmitters with Dycon control panels using the D3301 ADD R radio receiver s it is important that several readings are taken to get an average received signal strength Ensure that the average received signal strength is 8 or more max 31 Do not install Dycon transmitters and receivers in a location where the received signal strength is on average below 8 In this case relocate the transmitters and or receiver s or add additional ADD R receivers Background radio noise the location of people or office nousehold property and atmospheric effects can make the received signal strength vary over time If these degrade the signal strength then the continuous supervisory transmissions will detect this and provide a warning After installation if supervisory warnings are displayed from time to time this indicates that the average signal strength at the receiver from that particular transmitter is too low for a reliable service In this case relocate the transmitters and or receiver s or add additional ADD R receivers to ensure that the average received signal strength is great enough that supervisory warnings are no longer displayed or are only displayed occasionally Where a range survey is conducted to survey a site for placement of short range detectors then it is recommended that a test receiver e g an ADD
64. e its jumper in the 23 position See the section on bus wiring for further addressing information Termination If the ADD R is connected at one of the ends of the bus a jumper link must be fitted to the TERM pins If the ADD R is connected at any other position on the bus a jumper link must not be fitted to the TERM pins When the TERM jumper is not used park it on one of the two pins See section on bus wiring for further information on addressing Shunting the Tamper Switch s The SHUNT jumper link will bypass the tamper circuit Remove the jumper link or park it on one of the two SHUNT pins for normal tamper switch operation Fit the jumper link to the two pins for ADD R operation with the lid open and or the back tamper switch bypassed Closing the lid with the shunt link in the shunted position will stop an exit from engineering mode and a warning message will be displayed on keypads D3000 Series Installation Manual D3000 INST O9H v3 45 ADD R cont d LED Indicators The ADD R may be fitted with up to 8 LED indicators These are red and green labelled 1 2 3 and 4 See Fig 48 LEDs will operate as shown below even when there is no bus communications from the ADD R to the control panel This means that an ADD R and 12 volt battery can be used to survey a site for placement of short range detectors Surveying is described at Appendix 3 Green LED 1 2 flashes every 2 seconds power and bus communications OK On solid p
65. e present on the bus wiring See system bus wiring on page 90 and refer to Appendix 4 to ensure that the voltage drop is within limits D3000 Series Installation Manual D3000 INST O9H v3 93 APPENDIX 1 Aerial Siting for GSM Radio Networks The VDN and GSM radio modems are supplied with an aerial and connecting lead The aerial should be mounted vertically at the point of strongest signal This is usually the highest point in the building often the loft area Installation standards may require that the aerial and its lead is totally within the protected area and not on the entry route ALWAYS do a site survey to find the area of strongest signal before installation Radio signals cannot pass through metal sheeting Large metal structures can affect radio signals therefore wherever possible avoid installing the aerial directly under metal roofs or within metal skinned buildings because this will reduce the signal strength and may inhibit operation completely If this is unavoidable the strongest signal will be found away from the metal roof or close to large external windows or skylights Note that some plaster board walls include a metal surface to one face Wherever possible do not install the aerial close 1 metre to cable runs ducting structural metalwork metal pipes water tank electronic equipment e g photocopiers fax machines etc These can have similar effects as metal roofs Reliable operation is unlikely with low
66. e proximity reader is to be used with a D3000 Series control panel TERM This link must be fitted only if the device is at the end of a bus SHUNT Fit this link to shunt the lid and back tamper switches When fitted a reminder will be given when exiting engineer mode I P In the position the I P input will require a negative applied signal In the position the I P input will require a positive applied signal 1 16 17 32 This link must be fitted in the 1 16 position D3000 Series Installation Manual D3000 INST O9H v3 29 Keypads The D3200 range of keypads offers different combinations of FSL inputs programmable outputs sounder output audio features card reading and cost All keypads allow operation and all engineering functions to be controlled Refer to the table on page 4 for a list of features Installation connection and operation are the same for all keypad types Up to 10 keypads may be connected to the bus on D3001 11 control panels Up to 3 keypads may be connected to the bus on the D3021 22 control panels All types are supplied with a fitting kit that includes all required EOL resistors etc All keypads measure 124 x 155 x 22mm h x w x d The case mounts directly onto a wall using any of the multiple mounting holes in the rear of the case There are multiple cable entry points on the rear of the case and cable knock outs on the top bottom and sides of the case See Fig 31 An engineer
67. e same line parallel connection the bell in the telephone may tinkle when the Control Panel is operating Dualcom alarm calls to the Alarm Receiving Centre WILL also be inhibited Connecting other telecomms equipment IN PARALLEL to the PSTN telephone line used by the Control Panel can stop the unit sending alarm calls to an Alarm Receiving Centre Digi Modem B AIRI Apparatus Parallel connection MUST NOT be PSTN used for the Control Panel when it is used in a security system Use only Serial Connection See below D3000 Series Installation Manual D3000 INST O9H v3 67 PSTN Line Connection control panel alone on line Your Telecom Service Provider should be asked to supply and fit an analogue line and an NTP with terminals near the alarm system For broadband connections see later in this section The alarm installer should then follow steps 1 2 and 4 below See Fig 74 Series Connection control panel and other equipment on line Your Telecom Service Provider should be asked to supply and fit an analogue line and an NTP with terminals near the alarm system The alarm installer should then follow steps 1 4 below See Fig 75 1 Use cable type 1 0 5mm CW1308 feed through the cable entry connect the cores to the control panel s telephone line terminals marked A and B 2 Connect the other end of the cable to the terminal block connections for the incoming telephone line marked A and B or 2 and 5 3
68. eived Acceptable OK Off Low On A weak GSM radio signal is being received Radio reporting may fail OK Off Low Off No GSM radio signal is being received Radio reporting will not operate LED4 Green 1 flash every 2 sec Powered and registered OK Table 28 Indicator LEDs eees Active OK Low LED4 ES Plug on GSM Radio Modem Fig 53 Operation For all LED indications see Table 28 Remote Access Security The control panel has two independent methods of stopping unauthorised programming by up downloading These security features are for off site up downloading only They do not operate when the system is in the engineering state or for controls using the system keypads Remote programming by up downloading may be enabled or disabled on any of the communication networks fitted to the D3001 alarm system These may be PSTN or ISDN telephone lines or the GSM radio networks Refer to the programming manual for details Current Consumption Refer to Appendix 4 for the current consumption of all units Use these figures when calculating battery capacities D3000 Series Installation Manual D3000 INST O9H v3 50 Output Board The plug on D3024 output board provides 8 programmable outputs and 3 inputs for connection to other signaling devices e g RedCare The outputs are open collector outputs i e OV at the pin when the event occurs rated at 50mA each The inputs are p
69. ement The D3001 monitors the temperature and adjusts the battery charging voltage If the temperature increases the charging voltage will decrease and vice versa Using this feature the life of the battery can be increased significantly Is there anything special need to do when installing a Dycon panel Not really One area where Dycon s panels differ to most other manufacturers is when a CS1070 or D D2070 radio signaling module is used Under these circumstances the same rules apply as when installing a DualCom D3000 Series Installation Manual D3000 INST O9H v3 15 Frequently Asked Questions cont d Why are the LEDs flashing on my CS1070 VDN radio modem If a CS1070 is fitted but it has not been programmed onto the system Menu C40 then the LEDs will display a traffic lights sequence i e red red amber green amber red Once the CS1070 is selected in the programming these LEDs will resume their normal functions as per a DualCom have just powered the system up for the first time why won t the keypad work A new system assumes that keypad with address 1 will be fitted if a keypad with another address is fitted the panel will not see it There are 2 possible solutions i Default the programming data as follows Place a short across the default pins then temporarily short the reset pins When the display reads Load Default Data remove the short from the default pins and press OK To defaul
70. equired identified by coloured bands on the body of the resistor A 2200 ohm resistor or 2K2 is identified by 3 red rings around it A 4700 ohm resistor or 4K7 is identified by a yellow ring a purple ring and one red ring around it To simplify identification Dycon supply painted resistors Red 2200 ohm Yellow 4700 ohm Note that it is essential that the resistors are connected as shown below Incorrect connection will make the zone operate incorrectly but will not result in damage The resistors must be fitted at the detector not at the control panel or ADD8 zone terminals Note that some manufacturers now fit resistors on the detector PCB and some provide a choice of resistors When using these detectors confirm that they are able to provide 2K2 across the Fault Masked contacts 4K7 across the Alarm contacts and a 2K2 End of Line resistor and DO NOT fit any additional resistors to the terminal blocks Check the detector s installation instructions for further information 2200 ohms Normally Closed 2200 ohms 4700 ohms All red or Alarm Fault and Allred or All yellow or redredred Tamper contacts redredred yellow purple red Tamper Alarm or Fault Masked Tamper iii Alarm Zone used as EOL FSL Zone Input Tamper Input Fig 95 Fig 94 sll zone Tamper be Fig 96 Closed Loop Must not be used on Zone inputs D3000 Series Installation Manual D3000 INST 09H v3 82 Zone Inputs cont d Normall
71. er features can be programmed later but we recommend that you do it now to avoid confusion Refer to menus C10 to C14 in the Programming Manual 4 Groups Select the exit mode and attributes for each of the groups A group will be unused and cannot be programmed if no zones have been associated with it Group names timers and other features can be programmed later but we recommend that you do it now to avoid confusion Refer to menus D60 to D62 in the Programming Manual 5 Quick Set Keys Decide how the Quick Set keys are to be used and associate one or more groups to them A group will be unused and cannot be associated if no zones have been associated with it Refer to menu D82 in the Programming Manual Operational Considerations UserGroup The D3001 and D3011 control panels can support up to 20 groups and each operator may be given access to any or all of these groups This selection is called the UserGroup An operator can only set and unset groups that are in their UserGroup See KeypadGroups and Quick Set keys below for additional information AutoGroups Each operator is allocated an AutoGroup which can be any or all of the groups in that Operator s UserGroup AutoGroups are operated without having to use the set unset menu The group s in that operator s AutoGroup will be set and unset when that operator code is entered and the OK key is pressed e g 123 4 OK See KeypadGroups and Quick Set keys below for additi
72. er to page 71 3 Wire free Detectors Determine the location of wire free detectors With a test transmitter and test receiver ADD R or D4220 confirm that the quantity and proposed location s of receiver s will be sufficient to provide a good signal strength from all detectors On larger sites more than one ADD R receiver may be required to provide that a good strength radio signal is received from all of the detectors The D3001 and D3011 control panels can have up to 8 ADD Rs connected on the bus line 64 total detectors per Control Panel The D3021 control panel can have up to 2 ADD Rs connected 16 total detectors per Control Panel Refer to Appendix 3 Where handheld PA transmitters will be used ensure that the quantity and proposed location s of ADD R receivers is sufficient to provide good signal strength from all locations on the site Refer to Appendix 3 4 Power and Battery Requirement Very important Estimate the power requirements of all alarm equipment detectors and sounders both internal and external Calculate voltage drops along cables Ensure that sufficient cable is available to keep the voltage drops within specifications and or estimate the number of additional ADD8PSU power supplies that will be required See pages 79 to 85 pages 94 to 97 and Appendix 4 5 Equipment Required Confirm the number required and locations of keypads proximity readers ADD8s ADD8PSUs ADD Rs and wireless detectors 6 Space Avai
73. g Device A dual path signalling device such as DualCom or RedCARE is triggered from the programmable outputs on the D3024 output board The LF input on the D3024 is connected to the DualCom line fault output and output 1 on the control panel programmed as ATS TEST is connected to the DualCom test pins see wiring diagram opposite zont Pore When the control panel detects a line fault the ATS TEST output is used to interrogate the status of the line fault The DualCom then keeps the line fault signal active for a dual line fault or temporarily removes FY oo the signal for a single line fault If the ATS TEST output is activated when the DualCom is not rem ots 7K 2 eia in a line fault condition this will initiate a test call g on each signalling path Powe 7K pow The operation of the ATS TEST output type complies j with the requirements of BSIA Form 175 D3000 Series Installation Manual D3000 INST 09H v3 74 System Bus Wiring The system bus connection between the control panel ADD8s keypads ADD8PSUs and ADD Rs is by a 4 wire system bus This is designed to use normal 7 020 low voltage alarm style wiring Screened cable or twisted types are not required The bus may be up to 1000 metres long D3001 and D3011 control panels have 2 separate system buses The D3021 and D3022 control panels have only one bus Each bus is wired as shown Typical system bus arrangements are shown below
74. g protocol DTMF Fast Format Alarms Reporting Protocol A protocol that is a sequence of analogue tones push button telephone tones used to send via telephone lines a transmission to receiving equipment at an ARC and to receive checking and acknowledgement replies from that receiving equipment 8 or 16 channel DTMF Fast Format protocol is commonly used in burglar or intrusion alarm equipment Dualcom 96 Alarms Reporting Protocol A digital protocol that is a sequence of ASCII characters used to send via telephone radio or other data network a transmission to receiving equipment at an ARC and to receive checking and acknowledgement replies from that receiving equipment 8 or 16 channel Dualcom96 protocol is commonly used in burglar or intrusion alarm equipment Earth Loop Calling An older type of analogue PSTN or analogue PABX extension line Normally provided with no DC voltage present on the line Requires the line to be connected to earth to obtain a dial tone Dycon products cannot be used with this type of telephone line EEPROM Electrically Erasable Programmable Read Only Memory A type of NVM See NVM EOL End Of Line Loop A two wire connection between an alarm system and a detection device One resistor is fitted to the loop at the detection device together with a switch The detection device changes the state of the switch to signal that it has detected something The alarm system measures the resistance of the loop and
75. ght n Ka SSO0OO0C0000 Audio bus terminals DIM Jumper Link gt Tamper Switch RESET pins i Ti Factory Service Connector D3201 02 11 12 Mk2 Keypad Circuit Board Fig 35 Programming All keypads connected to the system must have a individual bus addresses Ensure that one keypad has its address ID 1 The rotary address switch must be turned to an address in the range 1 to 10 on D3001 11 systems The rotary address switch must be turned to an address in the range 1 to 3 on D3021 22 systems This rotary address switch number must be different from all other keypads on the bus The 123 selector next to the rotary address switch must have its jumper in the 23 position See the section on bus wiring for further addressing information D3000 Series Installation Manual D3000 INST O9H v3 32 Keypads cont d Display Backlighting This feature keeps the display backlight on permanently dim to help a user find the keypad when installed in dark areas Normal operation is with the display backlight off until a key is operated on the keypad The DIM selector on Mk1 keypads have 3 pins Using the jumper link select the center and the pin furthest from the display to keep the backlight on See Fig 34 The Mk2 keypad has 2 DIM pins Fit the jumper link to these pins to keep the backlight on See Fig 35 Shunting the Tamper Switch s The SHUNT jumper will bypass the tamper circuit Remove the jumper link or
76. hat keypad Quick Set Keys Each Quick Set key A B C or D can be associated with any combination of the groups on the system Quick Set keys are a system function Any operator can use any Quick Set key at any keypad The group s associated with a particular Quick Set key is the same whichever keypad is used The group s associated with a Quick Set key do not have to be the same as that keypad s KeypadGroup If an operator tries to set the system via a Quick Set key that is associated with group s that are not in that operator s UserGroup then the Quick Set action will be completely ignored and the display will read Function Not Allowed Alarm Reporting These control panels will not transmit alarms via PSTN nor VDN GSM when the system is part set Where alarm reporting to the ARC is required when one or more groups are unset ensure that the Always Full Set attribute is enabled in one or more group D3000 Series Installation Manual D3000 INST O9H v3 10 Site Survey It is strongly recommend that a site survey is conducted prior to installation of an alarm system This is to confirm that correct and sufficient equipment is available and that the equipment is placed in the optimum position for its best performance 1 VDN or GSM Radio Coverage Firstly and most important all control panels can support dual signalling features Where radio communications will be used with your alarm system VDN or GSM select the
77. hes The one with a spring fitted is a lid tamper switch only The case back tamper switch is operated by an activation lever moulded into the rear of the case This lever holds the switch in its closed position See Fig 39 To adjust loosen the case mounting screws then turn the back tamper screw further into or out of the wall until it operates the back tamper switch Press the case onto the wall then release it to hear the click from the back tamper switch Retighten the case mounting screws Rear of Case N Back Tamper Switch Wall Back Tamper o Adjustment Screw Fig 39 Circuit Board Side view of Tamper Switch Programming All ADD8s and ADD8PSUs connected to the system must have individual bus addresses Ensure that one ADD8 or ADD8PSU has its address ID 1 The rotary address switch must be turned to an address in the range 1 to 12 on D3001 11 systems The rotary address switch must be turned to an address in the range 1 to 2 on D3021 22 systems This rotary address switch number must be different from all other ADD8s and ADD8PSUs on the bus The 123 selector next to the rotary address switch must have its jumper in the 23 position See the section on bus wiring for further addressing information Termination If the ADD8 is connected at one of the ends of the bus a jumper link must be fitted to the TERM pins If the ADD8 is connected at any other position on the bus a jumper link must not be fi
78. hm resistor See page 89 D3000 Series Installation Manual D3000 INST O9H v3 23 D3001 and D3011 Control Panels cont d LED Indicators On the D3001 and D3011 Control Panels there are several indicator LEDs See Fig 32 and 33 The REVERSE polarity battery LED will be lit if either or both batteries are incorrectly connected to the battery terminals The FAIL battery LED will be lit if the battery Load Check has failed This indicates a battery s with very low capacity and requires changing Each Red FUSE LED will be lit if its associated resettable fuse has tripped Remove power and reapply after 30 seconds to reset the fuse The ACTIVE LED will flash to show correct operation See Table 12 Active LED Indication Meaning 2 flashes in 1 second then Off for 1 second Normal Operation Fast flashing 3 flashes per second Programming Up downloading in progress Off Fault detected on Panel PCB On solid Fault detected on Panel PCB Table 12 Current Consumption Refer to Appendix 4 for the current consumption of all units Note that an internal sounder if connected will require an additional 400mA Use these figures when calculating the battery capacities Auxiliary Power Outputs The D3001 and D3011 control panels have 3 auxiliary power outputs that can be used to supply 12 volt power to additional equipment See Fig 27 and 28 Auxiliary 12 volt power output 1 1 amp for any additional equip
79. holding the circuit board then remove the circuit board from the ADD8 PSU case See Fig 41 Mark the position of the case single top mounting Drill the wall then mount the case using one screw or bolt at this point Ensure the case is level then mark the position of the two lower mountings Remove the case drill the wall then mount the case using all three mounting points The case and batteries can weigh up to 20 kilogrammes Select suitable mountings Rawl plug fixing into a solid wall using 1 5 inch No10 screws is recommended Re install the circuit board in the control panel case and replace its 2 top fixing screws then tighten all 4 fixing screws The various connections options to the circuit board are described later in this manual Refer to Table 22 Subject Page Number System Bus Wiring 90 Zone Inputs 98 Tamper Inputs 100 Internal Sounders 101 External Siren Bell and Strobe 102 Programmable Outputs 104 Power Supplies and Batteries 105 Auxiliary Power Outputs 109 Table 22 D3000 Series Installation Manual D3000 INST O9H v3 39 ADD8PSU cont d Programming All ADD8s and ADD8PSUs connected to the system must have individual bus addresses Ensure that one ADD8 or ADD8PSU has its address ID 1 The rotary address switch must be turned to an address in the range 1 to 12 on D3001 11 systems ADD8PSUs cannot be used with D3021 or D3022 systems This rotary address switch number mus
80. hone line into the case Remove the fuse from the mains fused terminal block and connect the mains supply cable Observe electrical safety precautions Do not replace the mains fuse yet and do not connect the battery s Configure and fit additional plug on equipment to the control panel circuit board as required When plugging on units ensure that they are correctly aligned See pages 51 to 57 Connect wiring from detectors to zone input terminals on the circuit board as required See pages 18 to 27 and 87 to 89 Connect bus wiring from ADDs and keypads to the control panel NETWORK terminals as required Some control panels have facilities for 2 separate networks See pages 79 to 85 and Appendix 4 Connect 12 volt supplies to detectors and other equipment from the control panel AUX 12V terminals as required See pages 18 to 27 and 98 Connect wiring from internal sounders to the control panel s SOUNDER terminals as required These items consume a lot of current Ensure wiring is sufficient See pages 18 to 27 page 90 and Appendix 4 Connect wiring from external sirens bells and or strobe lights to the control panel s BELL TRIG and STR terminals as required See pages 18 to 27 and pages 91 to 92 Connect the telephone line to the PSTN Digi Modem See pages 70 to 78 Connect the radio aerial lead to the optional plug on VDN or GSM radio modem Note that the radio aerial must be installed in a position where there is an adequate radio s
81. hould only be undertaken by a qualified electrician The D3000 Series range of alarm system products may only be installed by a professional installer D3000 Series Installation Manual D3000 INST O9H v3 104 APPENDIX 6 European PSTN Approval The control panel s on board Digi Modem meets the requirements of the EU PSTN standard TBR21 and is approved for connection to any exchange line forming part of a Public Switched Telephone Network PSTN AHCTR210 001 Declaration of Network Compatibility The equipment has been approved in accordance with Council Decision 98 EC 5 for pan European single terminal connection to the Public Switched Telephone Network PSTN However due to differences between the individual PSTNs provided in different countries the approval does not of itself give an unconditional assurance of successful operation on every PSTN network termination point In the event of problems you should contact your equipment supplier in the first instance AHCTR211 001 Statement to Notified Body Vendor and User The equipment has been approved in accordance with Council Decision 98 EC 5 for pan European single terminal connection to the Public Switched Telephone Network PSTN The equipment has been designed for use in all 17 EU countries plus Switzerland but may have interworking difficulties in Germany and Greece Approval Authority CE0168 Approval Number for Dualcom range 608777
82. ignal See pages 51 to 56 an Appendix 1 Remember it is always easier to find the point of strongest signal for the aerial before the equipment is fitted to a wall Moving aerials cables trunking etc after installation is wasted time and effort Configure and install all keypads and connect to the bus cable as required Connect detectors and output devices at each keypad as required Ensure that each keypad s bus address jumper is in the 23 position and the bus address selector is set to a different number from each other keypad Ensure that one keypad s bus address selector is set to 1 Make a note of the number for later programming See pages 30 to 35 An internal sounder can be connected to a keypad These items consume a lot of current Ensure bus wiring is sufficient See page 90 D3000 Series Installation Manual D3000 INST O9H v3 12 Installation cont d 16 17 18 19 20 21 Connect wiring from detectors to zone input terminals on the keypad s as required Connect 12 volt supplies to detectors and other equipment from the keypad s AUX 12V terminals as required Connect wiring from internal sounders to the control panel s SND terminals as required See pages 87 and 88 Configure and install all ADD8 units and connect to the bus cable as required Connect detectors and output devices at each ADD8 as required Ensure that each ADD8 s bus address jumper is in the 23 position and the bus
83. indicator LED to show if the fuse has tripped If the current on this output exceeds the maximum current the fuse will trip and the associated red LED will illuminate until the load on that output is removed To reset the fuse disconnect everything from the output and wait 30 seconds Repair the fault and reconnect to the output When checking the D3000 Series control panels and the ADD8PSU for faults always check the red fuse LEDs where fitted before powering the system off This will aid fault rectification The log will also contain the fault information and the date and time that the fault occurred The TAMP terminal is the connection to the tamper loop for the bell sounder and strobe unit The tamper loop is programmable and may be selected as normally closed or EOL Where EOL is selected the tamper loop must be terminated by a 2200 ohm resistor to Ov The TAMP terminal must be connected to a switch that is normally held in the closed position the other connection of which is 0 volts The BELL or RTN terminal is the 0 volt terminal Opening the tamper switch or cutting the tamper or the 0 volt wires or where EOL is selected shorting the tamper wire to a 0 volt wire will cause a tamper alarm The TRIG terminal is a transistor output that will command the SAB and SCB to activate its bell sounder This output is programmable where the transistor may be programmed as normally off or normally on The transisto
84. ing the voltage drop along bus wiring and when calculating battery capacities Auxiliary Power Outputs There is one auxiliary 12 volt output The terminals are marked by amp A total of 750mA may be drawn from this output The current taken at this output flows along the bus wiring from the control panel or ADD8PSU Refer to the section on auxiliary power outputs and to bus wiring for information on bus voltage drop See pages 79 to 85 and page 98 Safety When closing the case ensure that no wires are trapped between the back and lid or trapped around the tamper switch Refit the 2 lid securing screws Note The lid will fit either way round but the screws will only fit with the lid the correct way round Do not use longer screws than those provided when securing the lid to avoid damage to the case D3000 Series Installation Manual D3000 INST O9H v3 38 ADD8PSU The D3500 ADD8PSU has all the functions of the ADD8 plus a 3 Amp power supply and it has additional outputs and expansion options It may be fitted on the D3001 and D3011 bus in place of an ADD8 The ADD8PSU cannot be used with the D3021 control panel As with an ADD8 up to 8 detectors may be connected on FSL loops and there are 4 fully programmable outputs plus an output for an internal sounder In addition the ADD8PSU has outputs for external sounders and strobes and two of the programmable outputs are relay types There are three fused 12 volts output
85. ings Remove the case drill the wall then mount the case using all three mounting points The case and batteries can weigh up to 8 kilogrammes Select suitable mountings Rawl plug fixing into a solid wall using 1 5 inch No10 screws is recommended Re install the circuit board in the control panel case and replace its 3 fixing screws D3000 Series Installation Manual D3000 INST O9H v3 25 D3021 and D3022 Control Panels cont d Polarity of plug on units is shown by Pin 1 or a white triangle The various connections and plug on options to the circuit board are described later in this manual Refer to Fig 36 and Table 14 Subject Page Number PSTN Digi Modem 69 Plug On GSM Radio Modem 53 Plug On Output Board 56 Plug On Audio Board 57 System Bus Wiring 90 Zone Inputs 98 Tamper Inputs 100 Internal Sounders 101 External Siren Bell and Strobe 102 Programmable Outputs 104 Power Supplies and Batteries 105 Auxiliary Power Outputs 109 Table 14 Plug on Audio Board Plug on connectors for Radio Modem GSM Mains Power Supply TERM jumper link Terminals Factory Service Connector A Kick Stop off Pins L Kick Start on Pins Default PSTNLED Reset Battery iQ bp z5 gt ee line Active LED l Terminals terminals RS232 Printer SirervBell amp Zone 1 4 F ic eri a a Strobe outputs
86. inutes while the smoke detector self calibrates When the LED indicator stops flashing learn in the smoke detector to the control panel by pressing the test button Select the mounting position high on a wall or suspended from a ceiling for optimum sensing of heated rising air containing smoke particles 7 Mount the smoke detector back plate using the screws provided 8 Fit the smoke detector onto its back plate and secure by rotating the smoke detector clockwise IRON D Test Button Ae Smoke sensing vents e LED Indicator Fig 67 Smoke detector Learning in The smoke detector is learnt in to the control panel by pressing the test button Test Button Press the test button to test operation of the unit When the unit is powered and operating correctly the LED will flash once and the siren will sound with 2 tones for 1 second Smoke Detector LED There is a red LED on the front of the smoke detector The LED will flash once every 4 5 minutes indication that the unit is powered and operating correctly The LED will flash when smoke is detected The LED will flash once when the test button is pressed Smoke Detector Siren There is a siren built inside the smoke detector The Siren will sound when smoke is detected The Siren will sound with 2 tones for 1 second when the test button is pressed The Siren will sound briefly every few minutes to indicate a low battery voltage Radio Transmissi
87. is in the ON position Whichever mode is used always check for correct operation with the LED T Mount the transmitter back plate and the magnet e g on a door and door frame using the screws provided With the door closed there should be no more than 10mm between the magnet and the detector Ensure that the tamper spring will operate against the mounting surface 8 Fit the door contact universal transmitter onto its back plate and secure with its single screw 9 When system testing is complete open the unit and put the test jumper in the Parked position Arrow showing magnet Alarm Loop lt 5 r sensingarea Tamper ice ay 2 w OOOO Magnet Tamper Switch and Sprin Fl 6 Oj O X e MWe S Test Jumper ie iennet a0 Test Jumper Cet MOD Magnetic Switch Switch disable sad disable Jumper Jumper LED Test Button i Pi A a Door Contact Connections and Controls Fig 64 Universal Transmitter 19 Fig 63 Larig Jumper in the Jumper in the on position i The door contact is leamt in to the i aaa Control Panel by pressing the Test Button Jumper Details Fig 65 Ensure that the location chosen for this item and the location s of the receiver s will provide a sufficiently strong radio signal to be received Refer to Appendix 3 Wire free Detectors D3000 Series Installation Manual D3000 INST O9H v3 57 Wire free Detectors cont d D4811 Door Contact Universal Transmitter
88. is required to be set for system full set has been set then the entire system can use the global bell timers to control the bell s When set to commercial mode the D3001 11 is an independent group setting control panel There are 20 groups that may be independently set and unset Each of the 208 zones can only be associated with one group i e groups cannot overlap There are no Vari Zones Keypads can be associated with groups Bell siren and strobe outputs may be associated with each group Four Quick Set keys on each keypad allow several groups to be set and unset together When set to domestic mode the D3001 11 is a part setting control panel There are 4 groups Groups cannot overlap Only one group may be set at any time Any or all of the 208 zone inputs may be configured as a Vari Zone A Vari Zone belongs to each of the 4 groups and can have a different action in each group Example showing Commercial Mode Zones within Groups and Quick Set Keys The D3021 22 Control Panel The D3021 and D3022 have up to 52 zone inputs Each is associated with 1 of up to 4 groups Groups may be set and unset using operator codes and or proximity tags cards There are up to 22 operator codes and prox tags incorporating user and engineers Each operator code can be associated with any or all of the 4 groups Fast setting and unsetting of a particular selection of groups is possible for each of the 22 operator codes Operator codes can hav
89. is required to charge a battery s in a fixed time 72 or 24 hours and the maximum current in Amps that may be drawn from the power supply at the same time 1x 2x 72 Hours 7Amp hour TAmpthour 17Amplhour 17Ampfhour 24 Hours Battery Batteries Battery Batteries Current fram Current from PSU to charge ms ENI PSU to charge battery in 72 z battery in 24 hours hours Max Current Max Current avaliable from 0 ae iia cy a available from PSU for s PSU for system system Table 57 D3000 Series Installation Manual D3000 INST O9H v3 1x 7 Ampihour Battery 2x 1x 2x 7Amp hour 17Ampfhour 17Ampihour Batteries Battery Batteries Table 52 91 Power Supplies and Batteries cont d Calculating the battery capacity required for the specified standby time 1 Determine the required battery standby time Call this time T Add all the current requirements for every piece of equipment that the battery will be powering Call this total current C 3 Multiply T by C by 1 1 This is the Amp Hour capacity of the battery required Choose a battery with this or greater capacity Calculating the current required to recharge the battery within the specified time 1 Determine the battery recharge time Call this time T 2 Read the battery capacity from the battery s that will be recharged Call this value C 3 Multiply C by 1 1 then divide by T This is the current that the power supply must provide to recharge
90. ity readers and 4 Adds A fully expanded D3022 system has 52 FSL inputs 25 fully programmable outputs and 8 internal sounders Refer to the tables on page 4 All control panels are supplied with a fitting kit that includes all required screws EOL resistors fuses etc The D3001 measures 400 x 300 x 105 h x wx d mm and has space to accommodate one or two 7Ah batteries size 155 x 105 x 70 h x wx d mm The D3011 measures 400 x 400 x 115 hx wxd mm and has space to accommodate one or two 17Ah batteries size 170 x 180 x 80 hx wx d mm or up to four 7Ah batteries size 155 x 105 x 70 hx wx dmm The D3021 22 measures 260 x 320 x 100 h x w x d mm and has space to accommodate one or two 7Ah batteries size 155 x 105 x 70 h x w xd mm Refer to the section on power supplies and batteries to determine the batteries required for the system The D3001 and D3011 control panels case stands away from the wall by 12mm There are multiple cable entry points on the rear of the case and sufficient space behind the case for cables There are also cable knock outs on the top and bottom of the case Supplied cable entries have smooth edges but knock out holes do not Use of grommets is recommended and may be required by installation standards Cable ties should be used at the cable tie points to secure cables where they enter the case Where a battery space is unused on the D3001 and D3011 control panels the space may be used to mount an ADD8 Moun
91. l distributors including CPC Part Number TE 04367 or TE04070 Farnell Part Number 418 5328 or 506 0205 Maplin Part Number A61AK or A72AG Fig 80 D0730 Serial Connection to a PSTN and Broadband telephone line is shown in Security ADSL filter Fig 81 The installer must ensure that 1 The user s telephone wiring is disconnected from the NTP and reconnected to the D0730 ADSL filter only 2 The NTP connects only to the D0730 ADSL filter and to no other wiring or telephone sockets 3 The wiring between the NTP and the D0730 ADSL filter cannot be unplugged by the user 4 The user cannot plug a phone fax etc into the NTP 5 The terminals 2 3 and 5 A and B and A1 and B1 are connected exactly as shown Analogue amp ADSL servios provided ADSL Filter amp securty equipment by the Network Gervice Provider in a tamper profacted enciosure PSTN Connection using the D0730 Security ADSL Filter Fig 81 D3000 Series Installation Manual D3000 INST O9H v3 72 Serial Connection using a master socket to a PSTN and broadband telephone line is shown in Fig 82 This allows a 2 wire connection to the NTP which can make wiring easier but requires the installer to fit a master socket A PSTN master socket type LUU2 4A is suitable and has screw terminals These can be obtained from many electrical distributors including CPC Part Number TE 00666 Farnell Part Number 916 638 Maplin Part Number FT48C Rapid Part Number 24
92. l sounder outputs for 16 ohm speakers The D3021 system when fully expanded has 36 FSL wired inputs 16 wireless inputs 1 siren bell output SAB SCB 1 strobe output 15 programmable outputs 1 relay 14 transistor and 6 internal sounder outputs for 16 ohm speakers The D3021 system when fully expanded has 52 FSL wired inputs 1 siren bell output SAB SCB 1 strobe output 25 programmable outputs 1 relay 24 transistor and 8 internal sounder outputs for 16 ohm speakers The D3001 11 control panel and ADD8PSUs incorporate a 3 Amp Switched Mode power supply with integral current sensing and measurement temperature compensation battery condition testing plus reverse and deep discharge protection Two case sizes are available for the control panel The D3001 can accommodate two 7Ah batteries The D3011 has space for up to two 17Ah batteries or four 7Ah batteries The D3021 and D3022 incorporate a 1 2 Amp Switched Mode power supply and the case has space for two 7Ah batteries All control panels include a serial port for connection to a printer temporary or permanent An optional engineer s keypad may be plugged into the control panel or ADD or ADD8PSU or ADD R throughout the system All control panels may be programmed using any keypad or an engineer s keypad Remote programming downloading is supported via multiple transmission paths The D3054 programmer is software that runs on a PC and may be connected to the control panel via PSTN VDN or
93. lable Ensure that there is sufficient space to mount the control panel 7 Mains Supply Ensure that there is a suitable mains fused spur connection point for the supply of mains power to the control panel If one requires fitting contact a qualified electrician D3000 Series Installation Manual D3000 INST O9H v3 11 Installation 1 10 11 12 13 14 15 If you are new to the D3000 Series see Appendix 5 This describes a basic installation using a D3001 control panel and keypad This is ideal for learning about the basic features in these products Ensure that a site survey has been done This will locate the optimum positions for the control panel ADDs radio aerials etc This is important If this has not been done do it now See page 11 All D3000 Series systems are fully programmable Any input or any output on any component of the system may be programmed as required Install bus wiring within the protected premises to meet the requirements of the site survey s measurements and calculations See page 79 to 85 Refer also to Appendix 4 Remove the circuit board from the control panel case Mark and drill the wall Mount the case on the wall The case and batteries can weigh up to 20 kilogrammes Select suitable mountings For heavier cases Rawl plugs and 1 5 inch No10 screws are recommended Replace the circuit board See pages 18 to 27 Route all cables mains power radio aerial lead and telep
94. lephone The data contained identifies the subscriber to that network allowing billing and other user related services to be associated with an individual or company SMS The GSM Short Message Service Service provided by companies supplying a GSM communications system where a short text message may be sent to and from GSM mobile phones and read on the GSM mobile telephone display SMS Message Centre SMS messages are not sent directly from one GSM phone or Dualcom to another GSM telephone All messages are first sent to a Message Centre operated by the GSM Network Provider and then forwarded to the selected mobile telephone s This normally takes a few seconds but delays of 30 minutes or more may be experienced during busy periods Terminal Adapter A device that connects to the S bus connection of an ISDN Network Termination Point and adapts the digital S bus data i e protocol data speed structure to that required e g the conversion may be to analogue PSTN or to a serial port for cable connection to a PC serial COM port User Codes To meet the requirements of the European Standards user codes and engineer codes have now been replaced with a single unified code structure Rather than having 64 users and 4 engineers 20 users and 2 engineers on D3021 the system now comprises 68 users 22 on D3021 It is now possible to allocate ANY user as access level 2 user or access level 3 engineer defined by whether that user h
95. link Network 2 TERM jumper link Network 1 Keypad RESET pins NVM DEFAULT pins EJE PSTN Line Parallel Handset Fig X5 7 Resistors for Zone Inputs 1 2 and 3 4700 ohms All Yellow or Yellow Purple Red Across the Alarm contact 2200 ohms All Red or Red Red Red In series with the contact Resistors for Zone Inputs 5 to 8 2200 ohms All Red or Red Red Red D3000 Series Installation Manual D3000 INST O9H v3 103 Specification APPENDIX 5 Model D3001 Grade 3 D3021 Grade 2 D3022 Grade 3 Dimensions 430 x 345 x 90 260 x 320 x87 h xw x din mm Weight 3kg 2kg Telephone path Standard PSTN technology Radio path GSM Abort facility Built in Power requirement 190 265 v AC 50 VA Low battery 10 8 11 0 volts falling 11 8 12 0v recovery Outputs Siren bell strobe 1 relay amp 3 D3001 or 2 D3021 and D3022 open collector programmable 2 open collector programmable on keypads D3202 and 4 on each ADD8 Inputs 8 FSL 144 additional 8 FSL 2 ADD8 16 8 FSL 4 ADD8 12 FSL using ADD8 and on RF 12 0n3 on remote keypads keypads total 152 remote keypads total total 52 52 Temperature 20 to 60 transit 4 C to 50 C operating Humidity 0 80 non condensing Mounting Any orientation Warranty 2 years Regulatory Constraints This unit connects to mains power Installation of any mains wiring s
96. lls ISDN 2 Basic Rate Up to 2 ISDN 2e Basic Rate Up to 2 ISDN 30 Primary Rate Up to 30 Table 35 An ISDN line is always terminated at the user s premises by an NTP Network Termination Point which is provided by the Telecomms Service Provider The NTP is a socket or connection where the user s equipment can be connected The service supplied to the user from the NTP may vary The digital connection on the NTP is called the S bus The S bus allows many different types of digital communication equipment to be connected e g an ISDN interface card in a PC In many cases the ISDN NTP operates using power supplied from the exchange equipment via the ISDN telephone line However some types of NTP may require a connection to the mains supply at the user s premises Some ISDN NTPs include a converter to provide analogue sockets e g Home Highway See below ISDN2e Integrated System Digital Network 2 channel A basic rate ISDN telephone line can carry the equivalent of two simultaneous calls In UK a basic rate ISDN line is called ISDN2 or ISDN2e Some suppliers call an ISDN2 line Home Highway or Business Highway See below Where an ISDN2 line is fitted but an analogue line is required e g for the control panel then the D0700 ISDN analogue converter may be used The D0700 has some important features especially for security communications including over ride line grab Refer to the D0700 manual and see Fig
97. logue PSTN Telephone Line The analogue PSTN is a communication network where the line from the exchange equipment and the service supplied to the subscriber is analogue i e not digital See Fig 72 A telephone line is always terminated at the user s premises by an NTP Network Termination Point which is provided by the Telecomms Service Provider This is a socket or connection where the user s equipment can be connected Some NTPs provide a socket and terminals for connection In many cases the NTP operates using power supplied from the exchange equipment via the telephone line An analogue PSTN telephone line may be provided by BT or any of the other 44 telecoms service providers in UK The Control Panel can be connected here See Fig 72 analogue telephone Analogue PSTN service provided equipment by the Network Service Provider Analogue PSTN Telephone Line Fig 72 Remote Access Security The D3000 Series control panels have two independent methods of stopping unauthorised programming by up downloading These security features are for off site up downloading only They do not operate when the system is in the engineering state or for controls using the system keypads Remote programming by up downloading may be enabled or disabled on any of the communication networks fitted to a D3000 Series alarm system These may be PSTN telephone lines or the VDN or GSM radio networks Refer to the programming manual for details
98. ly will always reset these cutouts To power up on batteries only connect the batteries then briefly 0 5 second short the two pins marked Kickstart ON This will reset the cutouts See Fig 23 and 35 To avoid having to disconnect the batteries when switching off firstly disconnect the mains supply by removing the mains fuse then briefly 0 5 second short the two pins marked Kickstart OFF See Fig 27 29 and 43 Note that the Kickstart terminals on the control panel will switch on and off the power supply in the control panel They will not control any additional ADD8PSUs Each additional ADD8PSU must be controlled as required by using their own Kickstart terminals Auxiliary Power Outputs The D3001 and D3011 control panels and ADD8PSUs each have 3 separately fused auxiliary power outputs The D3021 and D3022 control panels have 2 auxiliary power outputs Refer to the section on auxiliary power outputs for more information on page 98 Batteries and Standby Time The maximum current available from a power supply and the capacity of the fitted standby batteries will affect the maximum standby time It will also affect the recharge time and the current that is available to operate the system during the recharge time Simply look up the times and currents in tables See Table 50 51 and 52 It is possible to calculate these times currents etc See calculations below Security system and equipment standards define the time that equipment m
99. m the control panel or ADD8PSU Refer to the section on auxiliary power outputs and to bus wiring for information on bus voltage drop See pages 79 to 85 and page 98 Safety When closing the case ensure that no wires are trapped between the back and lid or trapped around the tamper switch Ensure that the hinge is correctly assembled lift the lid and click it shut at its top edge Replace the securing screw and close the transparent plastic that covers the display See Fig 32 Do not use a longer screw than that provided when securing the lid to avoid damage to internal circuits or wiring Ensure that the transparent plastic cover is closed by pressing on both its right hand and left hand edges D3000 Series Installation Manual D3000 INST O9H v3 33 Keypads cont d Engineer s Keypad An engineer s keypad may be used with D3001 11 while in the engineering mode to provide a keypad at the control panel ADD8 ADD8PSU or ADD R this feature is NOT available with D3021 or D3022 Simply plug the engineer s keypad into the socket on the control panel ADD8 ADD8PSU or ADD R The system will not exit engineering mode with the engineer s keypad fitted Inputs and Outputs When an engineer s keypad is connected to an alarm system its zone inputs and programmable outputs are disabled Termination An engineer s keypad should always have its TERM jumper parked on one of the two pins See section on bus wiring for further addre
100. mA charged May rise to 2 Amps when flat Table X4 1 D3000 Series Installation Manual D3000 INST O9H v3 101 APPENDIX 4 Setting up a Basic System Control Panel 1 Keypad 1 8 9 10 11 12 13 Set one keypad identity to ID 1 Connect this on the 4 wire network bus to the control panel This keypad is always enabled on a system See diagram for connection details Control panels are supplied pre loaded with the Factory Default Values To return a control panel to the Factory Default Values see menu C07 Connect 2 FSL resistors and a door contact to zone 1 input Connect a 2200 ohm resistor in series with the contact Connect a 4700 ohm resistor across the contact See diagram for connection details This will be the Entry Exit Door Connect 2 FSL resistors and a door contact to zone 2 input Connect a 2200 ohm resistor in series with the contact Connect a 4700 ohm resistor across the contact This will be the detector on the Entry Exit Route Connect 2 FSL resistors and a door contact to zone 3 input Connect a 2200 ohm resistor in series with the contact Connect a 4700 ohm resistor across the contact This will be a detector set for normal night operation Connect 5 resistors 2200 ohms each to the zone input terminals for zone 4 to 8 on the control panel Fit a wire link to tamper 1 input terminals a wire link to tamper 2 input terminals and a wire link from the bell tamper terminal to a Ov termin
101. mable Outputs Power Supplies and Batteries Auxiliary Power Outputs Appendix 1 Aerial Siting for GSM Radio Networks Appendix 2 Wire free Detectors ADD R Siting Range Aerial Options Appendix 3 Current Consumption of all Units Appendix 4 Setting up a Basic System Panel 1 Keypad Appendix 5 Specification and Regulations Appendix 6 Approvals Appendix 7 Glossary of Terms D3000 Series Installation Manual D3000 INST O9H v3 oR WwW 104 105 106 Introduction The D3001 11 21 22 control systems are designed to suit small to large size intruder alarm installations 8 to 208 detectors Extensive hardware and programmable options make these systems suitable for the national requirements of many countries and for installations to European Standard EN50131 1 Grade 2 and 3 Systems are fully adaptable to meet all initial design specifications Future expansion and additions may be made to meet changing requirements in the easiest manner imaginable i e any zone input on any unit panel ADD8 keypad ADD8PSU or ADD R may be programmed as a zone a tamper a 24 hour circuit a PA an Exit Terminate button etc in any order and in any group Equally any programmable output on any unit may be programmed to any of the 70 output type options See page 5 for tables of product features All control panels have fully supervised loop FSL Zone inputs All control panels have fully programmable outputs in addition to the normal bell a
102. many ADD8PSUs are used on the bus Power flows onto the bus from the ADD8PSU Network OUT terminals Power flows from the ADD8PSU away from the Control Panel See Fig 44 and 45 The ADD8PSU takes no power from the Bus on its Network IN terminals See Fig 44 Mode Selector Ensure that the Mode Selector jumper is in the System position See Fig 43 Current Consumption Refer to Appendix 4 for the current consumption of all units Note that an Internal Sounder if connected will require an additional 400mA Use these figures when calculating the battery capacities Auxiliary Power Outputs The ADD8PSU have 3 auxiliary power outputs that can be used to supply 12 volt power to additional equipment Each of these outputs is protected by a fuse that will automatically reset and an indicator LED to show if the fuse has tripped Auxiliary 12 volt power output 1 1 amp for any additional equipment Auxiliary 12 volt power output 2 1 amp for any additional equipment Auxiliary 12 volt power output 3 1 amp for any additional equipment Refer to the section on Auxiliary Power Outputs for more information See page 98 Safety The ADD8PSU is fitted with a fused terminal block for connection of a 230 volt AC mains supply This should only be connected by a qualified electrician Always observe electrical safety precautions See Fig 42 If the supplied fuse should fail determine the cause of the failure before replacing the fuse and only replace it b
103. ment Auxiliary 12 volt power output 2 1 amp for any additional equipment Auxiliary 12 volt power output 3 1 amp for any additional equipment Refer to the section on auxiliary power outputs for more information on page 98 Safety The control panel is fitted with a fused terminal block for connection of a 230 volt AC mains supply This should only be connected by a qualified electrician Always observe electrical safety precautions See Fig 30 and 31 D3000 Series Installation Manual D3000 INST O9H v3 24 D3021 and D3022 Control Panels Top Mounting Mains Terminal Block Power Supply Behind board Tamper Switch i Board Fixings o Board Fixings I E DI A err E E ee za oem 7 Ah Battery 7 Ah Battery Lower Mounting X behind battery D3021 and D3022 Control Panels Lower Mounting behind battery Fig 28 D3021 and D3022 Installation The lid of the control panel is secured by 2 screws To open the case remove these screws then remove the lid Note how the lid fits into the back of the case To mount the control panel on a wall first remove the circuit board to avoid damaging it Remove the 3 screws holding the circuit board then remove the circuit board from the control panel case See Fig 28 Mark the position of the case single top mounting Drill the wall then mount the case using one screw or bolt at this point Ensure the case is level then mark the position of the two lower mount
104. mper Switch Bus Address Reader 2 Connections Switch and Connections Jumper Rig Y1G1a WI Address R2 Sy2G2 a w2 ae gi e 222000 boro doe Mode went a me Tamper Switch Two Reader Door Entry Shunt Mode t S RDR2 S Sand Alone f Input Level Selector Stand Alone j negative applied Mode ee 5 positive applied Engineers f ora ecco e mE nw A GSopocooo Keypad ooog ocao CLOSE NO kola Rene AS Rae cpu s pee Be Connector ABCDABCD ACTIVE IP CNCNO Fig 30 TERM Contro Pane Bus Door Control Door Contro g Jumper Link Connections Relay Override Relay D3232 Controller Circuit Board ADDRESS All proximity reader controllers connected to the system must have individual bus addresses The rotary address switch must be turned to an address in the range 1 to A on D3001 3011 or 1 to 2 on D3021 3022 and must be different from all other proximity reader controllers on the bus The 3 pin jumper next to the rotary address switch must have its jumper in the 1 16 position See the section on bus wiring for further information on addressing CPU ACTIVE This flashes to indicate that the device is operational The flashing stops when the lid tamper and back tamper switches are closed to reduce power consumption D3000 Series Installation Manual D3000 INST O9H v3 28 Proximity Readers cont d Connections ABCD These are the connections to the bus and are wired in the same way as any other
105. n either or both tamper switches are opened Tamper restore signal when both tamper switches are closed Tamper signal when the anti tamper loop on the A T Terminals is opened Tamper restore signal when the anti tamper loop on the A T Terminals is closed Supervisory signal will be sent every 20 minutes Low battery signal when the supply voltage falls to the low voltage threshold Refer to Appendix 3 Transmission Details Refer to Appendix 3 Supervision Radio Signals Range Expectations Refer to Appendix 3 Range Expectations Supply Voltage Monitoring The 4 channel transmitter will transmit a low battery signal to the control panel when the supply voltage threshold is reached 9 5v 0 5v D3000 Series Installation Manual D3000 INST O9H v3 65 Telephone Line Connection The D3000 range of control panels and most other intruder alarm equipment requires an analogue telephone line connection Earth Loop Calling or Earth Calling types of analogue telephone line cannot be used The D3000 range of control panels cannot be connected directly to digital ISDN or digital or hybrid ADSL telephone lines There are several different types of telephone line available from different service providers Details of these different types of lines and connections follow All control panels have an on board Digi Modem included for alarm reporting and up downloading via the PSTN an analogue telephone line Ana
106. nal ADD8PSU power supplies is sufficient to provide adequate power for the system and for any other auxiliary apparatus drawing power from the system See below for further recommendations ADD and Monitoring The ADD8PSU incorporates an 8 input ADD8 This provides all the features of an ADD8 In addition all of the measurements from the power supply monitoring circuits are passed via the bus wiring to the control panel This ensures that all power supply monitoring e g the current being used for the whole system can be recorded printed and displayed during installation or maintenance or sent remotely via the up downloader Battery Condition Testing The power supplies in the D3000 Series control panels and in the ADD8PSU incorporate battery condition testing This may be programmed to occur hourly from one hour to 24 hours or it may be switched off The control panels test their batteries together connected in parallel The ADD8PSU tests each battery separately Battery condition testing is achieved by loading the battery with a heavy current load for a few seconds and measuring the voltage at the battery terminals This test will identify a battery that is incapable of supplying the full system load current This degradation is often due to age over charging operating at elevated temperatures or a battery internal fault Installation Temperature All lead acid gel batteries will give their maximum life when operated between 5 C and
107. nd strobe output plus a sounder output for internal sounders Full dual path alarm reporting PSTN and radio is available with a built in PSTN Digi Modem for telephone lines and plug on options for a VDN Vodafone Data Network or GSM Global System for Mobile Communications radio modem Plug on interface options allow for connection to other communication systems The network 4 core bus wiring provides system expansion via keypads ADD8s ADD8PSUs and ADD Rs Low cost and multimedia keypads are available The multimedia version has 4 FSL inputs 2 programmable outputs a sounder output and audio functions for a user help hands free 2 way speech system A proximity tag reader is also available to allow the system to be set and unset from outside the protected premises ADD8s have 8 FSL inputs 4 programmable outputs and a sounder output plus a socket where an engineer s keypad may be plugged in ADD8PSUs have the same facilities as an ADD8 plus they include a fully monitored 3 Amp power supply backup batteries and bell siren and strobe outputs The ADD R allows any of the Dycon range of 868 MHz wire free detectors to be used with the control panels More than one ADD R can be added to a system to provide coverage on large sites The D3001 11 systems when fully expanded have 144 FSL wired inputs 64 wireless inputs 13 siren bell outputs SAB SCB 13 strobe outputs 72 programmable outputs 25 relay 47 transistor and 23 interna
108. nd wait 30 seconds Repair the fault and reconnect to the output When checking the system for faults always check the red fuse LEDs before powering the system off This will aid fault rectification The log will also contain the fault information and the date and time that the fault occurred Termination The two end units on each system bus must have a jumper link fitted to their TERM pins All other units on that system bus must not have a jumper link fitted to their TERM pins Refer to the installation instructions for each type of control panel ADDs and keypads for the location of their TERM pins Incorrect fitment of TERM jumpers may result in incorrect control panel operation See Fig 99 and 100 Voltage Drop along Wiring System bus connections A and B are used to distribute power from the control panel or ADD8PSU to the ADD 8s keypads ADD Rs to their detectors and to output devices Refer to Appendix 4 for the current consumption of all units All wiring introduces a voltage drop The minimum voltage that is necessary at an ADD8 ADD R or keypad for correct operation is 10 0 volts Where a voltage below 10 0 volts is detected then a Low voltage warning will be given during installation What reduces the voltage drop 1 Wiring shorter and or thicker wiring less voltage drop 2 Current less current less voltage drop Obviously you can install a system and then measure the voltage at each item of equipment If it is
109. nditions by flashing when transmitting to alert the user that there is a problem In addition it will flash with every transmission when the test jumper is in the test position D4810 PIR Wire free Detector cont d Detection Coverage The detector will cover an area 110 wide and has a range of 15 metres when fixed at 2 metres above floor level The unit is more sensitive to movement across its field of view than movement towards or away from it PIR A Ea i S PIR 2ml i i 110degrees Wall Se J Wall YL j 15m Detection Side View Detection Top View Fig 61 Fig 62 Tamper Detection The Tamper switch and spring will detect the lid of the PIR being opened from its back plate To enable the back tamper that will detect the whole unit being removed from its mountings drill out the peg on the back plate that operates the tamper spring Place a screw in the wall so that it projects through the back plate and operates the tamper spring when the PIR lid is in place Radio Transmissions The radio transmitter in the unit will send the following signals Alarm signal when the PIR detects movement There is no restore signal sent by this unit Tamper signal when the tamper switch is opened Tamper restore signal when the tamper switch is closed Test signal also used for learning in will be sent when the test button is pressed Supervisory signal will be sent every 20 minutes Low battery signal when the battery voltage falls to
110. ns Do not mount the PIR where it is aimed at heating radiators fires or windows Tamper Detection The tamper switch and spring will detect the lid of the PIR being opened from its back plate To enable the back tamper to detect the whole unit being removed from its mountings drill out the peg on the back plate that operates the tamper spring Place a screw in the wall so that it projects into the case through the back plate and operates the tamper spring when the PIR lid is in place Radio Transmissions The radio transmitter in the unit will send the following signals Alarm signal when the PIR detects movement there is no Restore signal sent by this unit Tamper signal when the tamper switch is opened Tamper Restore when the tamper switch is closed Test signal also used for learning in will be sent when the test button is pressed Supervisory signal will be sent every 20 minutes Low battery signal when the battery voltage falls to the low voltage threshold Refer to Table 3 on page 8 for transmission details Range Expectations Refer to Table 1 on page 6 for range expectations Battery Replacement The PIR movement detector will transmit a low battery signal to the control panel when the low battery voltage threshold is reached This signal will be sent before the batteries are fully discharged and the detector operation ceases Replace the 3 6V Lithium battery when the low battery warning is first transmitted Refer to T
111. nstallation Manual D3000 INST O9H v3 53 D4809 Pet tolerant Wire free PIR Detector cont d PIR Sleep Time Sleep Time will conserve power and extend the unit s battery life During the sleep time radio transmissions are inhibited The PIR s sleep time is set at 1 minute when the test jumper is in the normal position It is possible to re trigger the sleep time and any movement that is detected during the sleep time will extend the sleep period by one more minute Thus continuous movement in an area will not cause continuous radio transmissions PIR s LED In normal operation mode the LED indicator will not light except in the following situations e When the PIR is in low battery condition the LED will light up for about 2 seconds every time it transmits a detected movement e When the cover is opened and the tamper switch is violated the LED will light up for 2 sec to indicate it is transmitting the tamper signal e When the tamper condition persists the LED will light up every time it transmits a detected movement However if the PIR is in test mode the LED will light up every time a movement is detected Detection Coverage The detector will cover an area 90 wide and has a range of 12 metres when fixed at 2 metres above floor level The unit is more sensitive to movement across its field of view than movement towards or away from it Mount the unit so that its field of view cannot be obstructed by shelves curtai
112. nt Opening or Sleep Timer Detection No restore removal from Yes Yes Test Button pressed for power tolerant PIR signal wall saving Movement Detector Magnet removed Opening or Alarm removal from Magnet close wall or cut the b4g11 Ta Contact Restore Tamper Loop Yes Yes Test Button pressed Universal Transmitter Loop broken Alarm Loop restored Restore Button A pressed Button B pressed Button A pressed D4812 Hand held Button C pressed No No No Button B pressed Controller Button B pressed No Button C pressed restore signals Button B pressed Smoke particles le Smoke detected Restore No Yes Yes Test Button pressed etector signal when air is clear Water or other conductor touching D4815 Water Detector detection pins No No Yes Yes Test Button pressed restore signal D4816 Long Range Both buttons pressed i Handheld Tilt for 30 seconds No Yes Yes Both buttons pressed Not Available Input 1 triggered Input 2 triggered Input 3 T A est Button 1 pressed triggered Input 4 Opening or oe triggered Restore removal from Yes Yes mar Boe i Prae signals on all Inputs wall Test Button 4 pressed Table X3 3 D3000 Series Installation Manual D3000 INST 09H v3 100 APPENDIX 3 Current Requirements The current requirements of all items in the D3000 Series range of control panels are listed below Use these figures when calculating the total current requirement of a system You will need to do this when calculating the power supply siz
113. o pull the lid off __ Breakouts I iM D3301 ADD R eco Abtcoaaco ogo The ADD R must not be installed inside the control panel case or inside the ADD8PSU case or any other metal case Fig 46 To mount the ADD R on a wall first remove the lid and unscrew the aerial from the circuit board D3000 Series Installation Manual D3000 INST 09H v3 44 ADD R cont d Remove the securing screw from the centre of the circuit board and then unclip the circuit board by releasing the two white plastic catches Remove the circuit board from the case See Fig 46 Mark the position of the selected case mounting holes Drill the wall Break out the selected cable entry point s then mount the case ensuring that the aerial is vertical straight up or down The break outs on the ends of the case may be opened by inserting a terminal screwdriver into the slot at the end of the knock out and twisting Re install the circuit board in the ADD R case Replace the securing screw Refit the aerial When fitting the aerial always hold the brass fitting NOT the shaft of the aerial When installing the system bus wiring ensure that the bus wiring is lead away from the circuit board and the aerial With the bus wiring close 10cm to the aerial then a reduction in radio range should be expected The various connections are described later in this manual Refer to sections System Bus Wiring See page 79 Tamper Switches Rea
114. o receive SMS commands from portable phones Note Most SIM cards are supplied for portable telephones and are only enabled for Speech and SMS As such they will not allow the D2070 to send alarms to an ARC or to use up downloading These SIM cards may be enabled for Data by your GSM Service Provider The SIM card has a number printed on it This is the SIM card serial number It is recommended that the SIM card serial number is recorded on the site records that will be stored at your office See Fig 50 The SIM card has telephone numbers allocated to it One number will be the number that you dial to send the unit an SMS message The second number is the number that you dial to send the unit a data call Some GSM Service Providers have just one number for both It is recommended that the number s is recorded on the site records that will be stored at your office SIM Cards Fig 50 D3000 Series Installation Manual D3000 INST O9H v3 48 Plug on GSM Radio Modem cont d Plug on GSM Radio Modem Plug on GSM Radio Modem location ona D3001 and D3011 Control Panel Polarity of Plug on units is shown by Pin 1 or a white triangle Fig 51 Self Registration Following installation and before the GSM radio modem can pass alarm signals it will automatically register onto the GSM network that is preset in its SIM card 1 When the registration process has started the yellow Active LED will start to flash slowly
115. ogramme Control Panel 2200 ohms E for EOL Tamper Input All redor red red red EOL Tamper Inputs Fig 99 Normally closed ce contacts Programme Control Panel i for Closed Loop Tamper Input 9 Closed Loop Tamper Inputs Fig 100 D3000 Series Installation Manual D3000 INST O9H v3 84 Internal Sounders The control panels keypads ADD8 and ADD8PSU can all drive internal sounders Internal sounders must be 16 ohm loudspeakers Other types of internal sounders must not be used On the D3001 and D3011 control panels each of the internal sounder outputs is protected by a fuse that will automatically reset On the D3001 and D3011 control panels and the ADD8 PSU there is an indicator LED to show if the fuse has blown If the load on the sounder output falls below the minimum impedance the sounder fuse will trip and the associated LED will illuminate The fuse will remain in the tripped state and the LED will remain lit until the load on that output is removed To reset the fuse disconnect everything from that output and wait 30 seconds Repair the fault and reconnect to the output The fuse may also reset when the sounder is silent When checking the system for faults always check the red fuse LEDs where fitted before powering the system off This will aid fault rectification The log will also contain the fault information together with the date amp time that the fault occurred The number of In
116. om The Dycon web site contains the latest copies of manuals for all Dycon products Please ensure that you are working from the latest version You can also download associated information and software samplers Sales shipping and contact information is here too For Vodafone GSM and Paknet radio signal strength predictions in UK using the postcode of the proposed installation site use the Vodafone Web Site http Awww vodafone co uk paknet D3000 Series Installation Manual D3000 INST O9H v3 14 Frequently Asked Questions What is the system specification Refer to the description on pages 2 and 3 and to the tables on page 5 What Keypads are available There are 4 types offering different features Refer to the keypad table on page 5 What standards do the panels meet Standard D3001 D3021 D3022 BS 4737 Yes Yes Yes ACPO 2000 Yes Yes Yes DD 243 Yes Yes Yes EN 50131 1 Grade 3 Grade 2 Grade 3 Table 8 How much current can be drawn from the programmable outputs Control panel output 1 voltage free relay contact rated at 1A Control panel outputs 2 3 and 4 500mA Add8 outputs 100mA Keypad outputs 100mA What loudspeakers can I use The number of loudspeakers depends on the drive capability and the way they are connected For more information on connecting loudspeakers refer to page 90 What cable should I use for the bus wiring Standard alarm cable PVC sheathed 7 0 2mm is fin
117. onal information Operator Set Unset Menu Each operator Code has a Menu 1 Access attribute If this is enabled then that operator can individually set and unset each of the groups in their UserGroup These groups are set and unset when the operator code is entered and the MENU key is pressed e g 1 2 3 4 MENU See KeypadGroups below for additional information D3000 Series Installation Manual D3000 INST O9H v3 9 System Planning and Design cont d Operator Set Unset Menu cont d When setting via Menu 1 the display indicates whether each group is set or unset S the group is set U the group is unset When the operator presses a NUMBER key the status for the relevant group changes between set and unset and vice versa When the new status is selected the operator presses the OK key Keypad Groups The D3001 and D3011 control panels can support up to 20 groups and each keypad or proximity reader may be given access to any or all of these groups This selection is called the KeypadGroup An operator has control of all of the groups in their UserGroup at any keypad that has the same groups in its KeypadGroup Where the KeypadGroup is different from that operator s UserGroup then only those groups that are in both the KeypadGroup and the UserGroup may be set and unset from that keypad e g an operator s UserGroup 1 2 5 6 7 and 8 A KeypadGroup 3 5 6 7 8 and 14 The operator cannot set and unset groups 1 and 2 from t
118. ons The radio transmitter in the unit will send the following signals Alarm signal when smoke is detected There is no Restore signal when the smoke clears Alarm signal when the test button is pressed Supervisory signal will be sent every 20 minutes Low battery signal when the battery voltage falls to the low voltage threshold There will be no tamper signals from this unit Refer to Appendix 3 Transmission Details Refer to Appendix 3 Supervision Radio Signals D3000 Series Installation Manual D3000 INST O9H v3 60 Wire free Detectors cont d D4814 Smoke Detector cont d Range Expectations Refer to Appendix 3 Range Expectations Battery Replacement The smoke detector will transmit a low battery signal to the receiver or control panel and the internal siren will sound briefly every few minutes to indicate a low battery voltage This signal will be sent before the batteries are fully discharged and the detector operation ceases It is especially important to replace batteries with good quality alkaline cells when the low battery warning if first transmitted Refer to Appendix 3 Batteries D3000 Series Installation Manual D3000 INST O9H v3 61 Wire free Detectors cont d D4815 Water Detector Manufacture marking WS 8L Installation 1 Ensure that the location chosen for this item and the location s of the receiver s will provide a sufficiently strong radio signal to be received Refe
119. ositive applied i e apply 12V to the pin to trigger the event 9 o o 9 o o Q o a a 3 a a 3 a o o 9 2 i o p D o D o o o a Q Q Q Q a 9 o to 2 5 Q a 2 D3024 Plug On Output Board D3024 Piug on Output Board location ona D3001 or D3011 Control Panel Fig 54 D3024 Plug On Output Board eealoooaaoca D3024 Plug on Output Board location ona D3021 or D3022 Control Panel Fig 55 D3000 Series Installation Manual D3000 INST 09H v3 51 Plug on Audio Board The D3025 audio board is for use with any of the D3000 range of control panels The multimedia keypads include a loudspeaker and microphone These may be used for the audio helpline feature and or for an intercom between keypads Where the audio helpline is required then the audio bus that connects to the audio terminals on all of the multimedia keypads must also be connected to the audio terminals on the optional plug on audio board that is fitted to the control panel Where the intercom alone is required then the optional plug on audio board is not required See the audio bus on page 86 for connection details D3025 Plug on Audio Board D3025 Plug on Audio Board a Ol ire l Se Wa PUDscpeToos sop scaacecpesqebopeasoRag CESE D3025 Plug on Audio Board location on a D3021 D3022 Control Panel Fig 56 a T oog Os O ouz D3025 Plug on Audio
120. ot Handheld D4220 0r ADEE Vertical Aerial 1090 299 Pe Available Not Vertical Dipole 700 250 50 Available Not Available Reception Vertical Yagi 1500 450 120 from one direction only D4820 4 Channel Transmitter Quarter wave Vertical D4220 or ADD R Quarter Wave 2000 600 150 Aerial or Vertical Vertical Aerial Dipole s a Vertical Dipole 1400 500 120 Reception from one Vertical Yagi 3000 900 240 direction only D4820 4 Channel Yagi with same Point to Transmitter Yagi D4220 or ADD R polarity as Tx 4000 1200 300 7 Point only Aerial Aerial Table X3 1 D3000 Series Installation Manual D3000 INST 09H v3 98 APPENDIX 2 cont d Battery Type Number of Replacement Battery Battery Life Transmitter Size Batteries Recommendation Expectation Mote D4810 PIR Movement Detector D4809 Pet tolerant PIR Movement AA 2 Duracell MN1500 2 years Detector D4811 Door Contact Universal AAA 2 Duracell MN2400 2 years Transmitter D4812 Handheld 23A 1 Duracell MN21 3 years Controller D4814 Smoke Detector AAA 4 Duracell MN2400 2 years D4815 Water Detector AAA 4 Duracell MN2400 2 years D4816 Long Range i Handheld Not Available D4820 4 Channel Requires 11 15 volt Quiescent 10mA Transmitter supply Active 250mA Table X3 2 Supervision Radio Signals Supervision transmissions are used to periodically test that all system radio devices are working and can
121. ot power up Replace the mains fuse to apply mains power to the control panel The control panel will power up and the batteries will start to charge See pages 18 to 27 On the control panel ensure that the green mains supply LED and the 12 Volt healthy LED are lit Ensure that the active LED is flashing See pages 18 to 27 On the D3001 and D3011 control panels ensure that no red fuse blown LEDs are lit See pages 18 to 27 On each keypad ensure that the green supply healthy LED is lit The display will show Initialising followed by Locating Add8s Locating RKPs Locating PSUs and Locating Add Rs To programme the system enter the Engineering Access Number on any keypad Factory Default 7890 OK Programme the system as required Refer to the programming manual charts or use the D3054 Programmer Put the system in Walk Test and by listening to the system sounders and the keypad displays ensure that all detectors operate as required Ensure that all siren bell strobe and internal sounders operate as required Ensure that all programmable outputs are connected and operate as required Ensure that all communication devices are connected and operate as required D3000 Series Installation Manual D3000 INST O9H v3 13 Factory Defaults amp Resetting Engineers Reset All Groups Unset When all groups are in the unset state the control system may be reset following an alarm by use of the
122. owered OK but no bus communications to the control panel Off no supply voltage or low supply voltage or another major problem Red LED 1 Not used Green LED 2 Normally off On a signal of any style is being received or checked Red LED 2 Normally off On a jamming radio signal is detected Green LED 3 Normally off On a valid signal from a Dycon wire free device is being received and is being passed to the control panel not active when surveying Red LED 3 Normally off On control panel in radio zone learn mode Red and Green Normally off Will only operate when green LED 2 or 3 is on LED 4 Green only on received signal strength is high Red and green on received signal strength is average Red only on received signal strength is low In normal operation when the D3301 is used with a control panel these LEDs will be lit for the period of a transmission only When surveying see Appendix 3 these LEDs will remain lit after each radio transmission Press the rear tamper switch to reset them ready for the next test transmission LED Indicators Aerial connector 43 ae _ ee Bus Address L eoo e Selector Switch ho Factory bal Service A Tamper Switch Connector a eo Shunt jumper enan A a i pp TERM pins 0 RESET pins z G a Bus wiring z connections Lid Tamper Switch te En be 8 gineers Keypad i Connector D3301 ADD R Circuit Board Fig 48 D3000 Series Installation
123. panel Refer to the sections for the wire free PIRs wire free door contact and other wire free detectors transmitters that operate with this receiver See pages 59 to 69 and Appendix 3 An ADD R case measures 168 x 108 x 35mm h x w x d with the aerial extending from the case the overall size is 250 x 108 x 35mm h x w x d The case mounts directly onto a wall or any surface using any of the multiple mounting holes in the rear of the case The aerial must be vertical There are multiple cable entry points on the rear of the case and cable knock outs on the top bottom and sides of the case See Fig 46 Installation The ADD R s must be installed in E the optimum position to receive the radio signals from the wire free detectors The aerial must be vertical Aerial Use a signal strength test receiver a or an ADD R and a 12 volt battery and a test transmitter e g a door contact transmitter to ensure that transmissions are sufficiently LIL strong from the locations of all E 43217 wire free detectors to the proposed Catch in if eee o location of the ADD R s release board See Appendix 3 for full details of i detector and receiver tests and Rear Tamper wish l t S i Board placement adjustment Screw P Sanuring Soraw Bs 9 The case clips shut and is secured by two screws To open the case taiit remove the two screws from the lid release board The case may now be opened by dia a an using fingers t
124. park it on one of the two pins for normal tamper switch operation Fit the jumper link to the two pins for keypad operation with the lid open Closing the lid with the shunt link fitted will stop an exit from Engineering Mode and a warning message will be displayed See Fig 34 and 35 Termination If the keypad is connected at one of the ends of the bus a jumper link must be fitted to the TERM pins If the keypad is connected at any other position on the bus a jumper link must not be fitted to the TERM pins When the TERM jumper is not used park it on one of the two pins An engineer s keypad should always have its TERM jumper parked on one of the two pins See below See section on bus wiring for further addressing information See Fig 34 and 35 Power Consumption The bus supply must be 10 volts or greater Refer to Appendix 4 for the current consumption of all units Note that an internal sounder if connected will require an additional 400mA Use these figures when calculating the voltage drop along bus wiring and when calculating battery capacities Reset The RESET pins reset the microprocessor in the keypad Use of these pins is not required during normal setup or operation See Fig 40 and 41 Auxiliary Power Outputs There is one auxiliary 12 volt output The terminals are marked by amp Up to 750mA may be drawn from this output See Fig 34 and 35 The current taken at this output flows along the bus wiring fro
125. power from the bus on its network IN terminals D3000 Series Installation Manual D3000 INST O9H v3 80 Audio Bus Wiring The multimedia keypads include a loudspeaker and microphone These may be used for the audio helpline feature and or for an intercom between keypads The audio bus connection between the multimedia keypads and the control panel is by a 2 wire bus This is designed to use normal low voltage alarm style multi core 7 020 wiring Screened cable or twisted types are not required The audio bus may be up to 1000 metres long The audio bus terminal connections at each unit are labelled AUDIO There is no polarity of audio Bus connection The audio bus may be wired as a straight line bus or star wired See Fig 93 Where ONLY the Intercom is required then the audio bus AUDIO terminals on each keypad must be connected to the audio bus AUDIO terminals on all other multimedia keypads Where the audio helpline is required then 1 The audio bus AUDIO terminals on each keypad must be connected to the audio bus AUDIO terminals on all other multimedia keypads AND 2 The audio bus must also be connected to the AUDIO terminals on the optional plug on audio board that is fitted to the control panel Control Panel optional Piug On Audio Board wn Ol re aa 57 Paodapoos cvccasascc0gducomsomND Coad GOEL Multi Media Keypad Typical Audio Bus wiring for 4 Keypads and a
126. r of Case The case includes 2 tamper switches The one with a spring fitted is a lid tamper switch only The case back tamper switch is operated by an activation lever moulded into the Wall rear of the case This lever holds the switch in its closed i position See Fig 47 Back Tamper F e Adjustment Screw To adjust loosen the case mounting screws then turn the iy back tamper screw further into or out of the wall until it operates the back tamper switch Press the case onto the Circuit Board wall then release it to hear the click from the back tamper oo Back Tamper Switch switch Re tighten the case mounting screws When the case back is mounted to the wall and the cables have been brought into the case the outer sleeve of cables Side view of Tamper Switch should be removed where they enter the case Always tie wrap cables to the cable guides before connecting them Fig 47 to the terminals Programming All ADD Rs connected to the system must have individual bus addresses Up to 8 ADD Rs may be connected to the bus on a D3001 or D3011 control panels Up to 2 ADD Rs may be connected to the bus on a D3021 control panel These must have an address in the range 1 to 8 The rotary address switch must be turned to an address in the range 1 to 8 The rotary address switch number must be different from all other ADD Rs on the bus The 3 pin selector next to the rotary address switch must hav
127. r to Appendix 3 Wire free Detectors Remove the two screws on the cover of the water detector and remove the cover Fit the 4 batteries in their holder Refer to Appendix 3 Batteries Learn in the water detector to the control panel by pressing the test button Select the mounting position so that the unit is well above the highest water level expected Mount the unit s back plate using the screws provided Ensure that the water resistant seal is correctly located in its channel on the back plate Fit the water detector onto its back plate and secure with the two screws 7 Using the clip provided mount the 2 pin water sensor at the level where a rising water level will transmit the signal Battery Holder OTAN D Test Button 2 pin Water Sensor Ja L gt Fig 68 Water detector Learning in The water detector is learnt in to the control panel by pressing the test button Radio Transmissions The radio transmitter in the unit will send the following signals Alarm signal when water or other conductor bridges its detection pins There is no restore signal when the detection pins become clear Alarm signal when the test button is pressed Supervisory signal will be sent every 20 minutes Low battery signal when the battery voltage falls to the low voltage threshold There will be no tamper signals from this unit Refer to Appendix 3 Transmission Details Refer to Appendix 3 Supe
128. r will switch to 0 volts when on and the output also has a 2200 ohm resistor to 12 volts The transistor can switch up to 500mA to 0 volts The STR terminal is a transistor output that will command the strobe light to activate This output is programmable where the transistor may be programmed as normally off or normally on The transistor will switch to 0 volts when on and the output also has a 2200 ohm resistor to 12 volts The transistor can switch up to 500mA to 0 volts Control Panel or ADD8PSU i2v C_9o O 6 el Amp se t Fig 103 Fig 118 shows the details of the siren bell and strobe connections available on the control panel and ADD8PSU No SAB or SCB is used in this example The tamper TAMP terminal must be connected to Ov via the wiring to the bell siren unit This example shows an EOL resistor of 2200 ohms and the normally closed tamper switch fitted in the bell siren unit The Ov wire could be connected to the BELL or RTN terminal The bell siren is driven from the control panel 12v supply when the TRIG terminal is switched to Ov In this example the bell siren must not draw more than 500mA maximum current D3000 Series Installation Manual D3000 INST O9H v3 86 Siren Bell and Strobe Connections cont d The strobe is driven from the control panel 12v supply when the STR terminal is switched to Ov In this example the strobe must not draw more than 500mA maximum current
129. rates the back tamper switch Press the case onto the wall then release it to hear the click from the back tamper switch Retighten the case mounting screws Fig 70 Power Requirement The 4 channel transmitter requires a supply voltage between 11 and 15 volts This will be typically 13 6 volts when used with the alarm system The current requirement is 10mA quiescent but this rises to 250mA for the period that the unit is transmitting typically 0 75 seconds Anti Clash Jumper Put this jumper in the position furthest from the screw terminals enable the anti clash transmissions Put this jumper in the position nearest the screw terminals to disable anti clash transmissions Anti clash transmissions will ensure that transmissions from other Dycon systems do not clash with this 4 channel transmitter which could result in lost signals When anti clash is disabled then each triggering event will result in one transmission of approx 750mS When anti clash is selected then each transmission will be repeated 3 times spaced by a random interval of 1 to 5 seconds Aerial connector LED Indicator Lid Tamper DC Supply Switch amp Spring Terminals 4 Test Switches Anti Tamper 1 for each channel m Terminals Anti Clash 2 selector pins amp jumper 4 channel Input Terminals 4 Channel Transmitter Circuit Board Fig 71 D3000 Series Installation Manual D3000 INST O9H v3 64 Wire free
130. re signal when the alarm shorting link is closed Tamper signal when the tamper switch is opened Tamper restore signal when the tamper switch is closed Tamper signal when the tamper loop is opened Tamper restore signal when the tamper loop is closed Test signal also used for learning in will be sent when the test button is pressed Supervisory signal will be sent every 20 minutes Low battery signal when the battery voltage falls to the low voltage threshold Refer to Appendix 3 Transmission Details Refer to Appendix 3 Supervision Radio Signals Range Expectations Refer to Appendix 3 Range Expectations Battery Replacement The door contact universal transmitter will transmit a low battery signal to the receiver or control panel when the low battery voltage threshold is reached This signal will be sent before the batteries are fully discharged and the detector operation ceases Replace batteries with good quality alkaline cells when the low battery warning if first transmitted Refer to Appendix 3 Batteries Operation with Normally Open detectors When the door contact universal transmitter is used with an external detector that is wired into the terminals then a closed contact is normally required that opens to trigger an alarm Some applications require a detector with a normally open contact Where the door contact universal transmitter is used with a D3000 Series control panel then that radio zone may
131. rotection All control panels and the ADD8PSU incorporate battery deep discharge protection When the mains supply fails the system will operate by drawing power from the standby batteries A low battery voltage signal will be sent to the ARC when the battery voltage falls below the preset value normally 11 volts When the battery voltage has fallen to about 10 volts the battery is almost completely empty and further discharge can damage or permanently destroy the battery s At this point the batteries will be switched off by the deep discharge protection circuits and all items that receive power from that power supply will switch off When the mains power is restored the powered items will restart and the standby batteries will recharge A battery voltage restored signal will be sent to the ARC when the battery voltage rises above the pre set value normally 12 volts Battery Reverse Connection Protection If the batteries are reverse connected incorrect polarity to the circuit board in a control panel or ADD8PSU it will not cause damage to the unit The unit will not operate and on the D3001 and D3011 control panels and the ADD8PSU the red REV LED will illuminate To correct the fault remove the battery connections and connect to the terminals correctly The Kick Start Terminals All power supplies have safety cutouts Powering up the system on batteries only no mains may not reset these cutouts Connecting the mains supp
132. rt Auxilliary 12 volt output on Pins amp Fuse trip LED Programmable outputs fring Tripped Fuse LED for Internal Sounder Reverse Polarity Power Internal Sounder output Supply Battery LED i Battery 2 Tripped Fuse LED for Siren Bell Connector SirervBell amp Strobe outputs P LED Active LED Engineers Keypad Connector Plug on connectors for Radio Modem Auxilliary 12 volt output amp Fuse trip LED Zone1 4 Bus 1 terminals Tripped Fuse LEDs for Bus Power GSM TERM jumper links Factory Service Connector z RESET pins a DEFAULT pins E 28222 Printer Sie Socket A Printer Socket Auxilliary 12 volt output amp Fuse trip LED Zone 5 8 Configuration NVM in socket Digi Modem Active LED Digi Modem telephone ISDN Interface line terminals Connector D3001 or D3011 Control Panel Circuit Board Manufactured during 2005 and later Fig 27 Telephone Line Connection Connect the analogue telephone line to the A and B terminals of the on board Digi Modem Connect other equipment that can use the telephone line to the A1 and B1 terminals Refer to the connection recommendations on pages 71 to 78 for all PSTN options Tamper Inputs All control panels have a bell tamper The D3001 and D3011 control panels have 2 other tamper inputs These are Tamper 1 lid Tamper switch Tamper 2 Where unused these must be terminated by a closed loop shorting link or a 2200 o
133. rvision Radio Signals Range Expectations Refer to Appendix 3 Range Expectations Battery Replacement The water detector will transmit a low battery signal to the control panel when the low battery voltage threshold is reached This signal will be sent before the batteries are fully discharged and the detector operation ceases Replace batteries with good quality alkaline cells when the low battery warning if first transmitted Refer to Appendix 3 Batteries D3000 Series Installation Manual D3000 INST O9H v3 62 Wire free Detectors cont d D4820 Long Range 4 Channel Transmitter A 4 Channel Transmitter case measures 168 x 108 x 35mm h x w x d When used with the Quarter wave aerial that extends from the case the overall size is 250 x 108 x 35mm h x w x d The case mounts directly onto a wall or any surface using any of the multiple mounting holes in the rear of the case There are multiple cable entry points on the rear of the case and cable knock outs on the top bottom and sides of the case See Fig 69 Installation 1 ADO 10 11 Ensure that the location chosen for this item and the location s of the receiver s will provide a sufficiently strong radio signal to be received Refer to site range survey for wire free detectors Remove the two screws from the front of the 4 channel transmitter case and remove the lid Remove the securing screw from the centre of the circuit board and then unclip the
134. ry power from the control panel Do NOT fit the GSM radio modem with mains or battery power applied Plug the GSM Radio Modem onto the Control Panel Ensure that the plug on connectors are aligned correctly See Fig 51 and 52 The GSM aerial should be mounted vertically at the point of strongest signal Installation standards may require that the aerial and its lead is totally within the protected area and not on the entry route ALWAYS do a site survey to find the area of strongest signal before installation Refer to Appendix 1 for aerial siting details Connect the GSM aerial and its lead Use the clip provided to ensure that the metal aerial connector does NOT touch any part of the Circuit Board or the battery terminals The D2070 GSM Radio Modem will require a SIM card for its operation A suitable GSM SIM card may be obtained from your GSM Service Provider Check if a GSM SIM Card has already been fitted by your equipment supplier It is fitted in a plastic carrier that may be ejected by pressing the button See Fig 63 and 64 Reconnect power to the control panel SIM Card Ensure that the SIM card is enabled for SMS amp Data Generally SMS is always provided with speech mode The D2070 requires Data transmission to send signals to an ARC The D2070 requires Data reception to receive up downloading The D2070 requires SMS transmission to send SMS text to portable phones The D2070 requires SMS reception t
135. s If the power supply A and B output is 13 6 volts the voltage at the A and B terminals at the first ADD8 will be 13 6 2 20 11 40 volts 10m 20m 30m 40m 50m 60m 70m 80m 90m 100m 50 mA 0 08 v 0 16v 0 24v 0 32v 0 40v 0 48 v 0 56v 0 64v 0 72v 0 80v 100 mA 0 16v 0 32v 0 48 v 0 64v 0 80v 0 96v 1 12v 1 28v 1 44v 1 60v 150 mA 0 24v 048v 0 72v 0 96v 1 20v 1 44v 1 68v 1 92v 2 16v 2 40v 200 mA 0 32 v 0 64v 0 96 v 1 28v 1 60v 1 92 v 2 24v 2 56v 288v 3 20v 250 mA 0 40v 0 80v 1 20v 1 60v 2 00 v 2 40v 2 80v 3 20v 3 60v 4 00v 300 mA 0 48v 0 96v 1 44v 1 92v 2 40 v 2 88 v 3 36 v 3 84v 4 32v 4 80v 350 mA 0 56v 1 12v 1 68 v 2 24v 2 80 v 3 36 v 3 92 v 4 48 v 5 04v 5 60v 400 mA 0 64v 1 28 v 1 92 v 2 56 v 3 20 v 3 84 v 4 48 v 5 12v 5 76v 6 40v 450 MA 0 72v 1 44v 2 16v 2 88 v 3 60 v 4 32 v 5 04v 5 76 v 6 48 v 7 20v 500 mA 0 80v 1 60v 2 40 v 3 20 v 4 00 v 4 80 v 5 60 v 6 40 v 7 20 v 8 00v 550 mA 0 88v 1 76 v 2 64v 3 52 v 4 40 v 5 28 v 6 16 v 7 04v 7 92v 8 80v 600 mA 0 96v 1 92 v 2 88 v 3 84 v 4 80 v 5 76 v 6 72 v 7 68 v 8 64v 9 60v Table 42 Panel ii Distance between the power supply and the first ADD is 50 metres The current flowing n
136. s at both ends when using the 4 channel transmitter the position polarity and alignment of the aerials is critical Wire free Detectors Range Expectations The maximum range that may be expected between a particular transmitting device and a receiver is dependent upon several factors These include the power of the transmitter the type of aerials at the transmitter and at the receiver and the lack of obstructions between the two aerials A site range survey should be conducted before any wire free detector s or receiver s are installed Refer to Table X3 1 D3000 Series Installation Manual D3000 INST O9H v3 96 Wire free Detectors cont d Aerial Types and Performance APPENDIX 2 cont d For the receivers and the 4 channel transmitter there are three types of aerial available Refer to Table X3 1 As a general guide Table X3 1 gives three range indications These are 1 The maximum range that may be expected with the aerials 8 metres above flat ground with a clear line of sight between the two 2 The maximum range that may be expected with the aerials 1 5 metres above flat ground with a clear line of sight between the two 3 The typical range in and around normal domestic buildings Quarter Wave Aerial An 11cm long quarter wave aerial is supplied with the ADD R This must be positioned vertical straight up down Reception will be from any direction not directly above or below Dipole Aeri
137. s i e if abort is selected as customer reset the tags will reset aborted alarms If PA is selected as customer reset the tags will reset PA alarms If unconfirmed alarms are selected as customer reset the tags will reset unconfirmed alarms If the system is selected as customer reset the tags will reset all alarms D3000 Series Installation Manual D3000 INST O9H v3 16 Frequently Asked Questions cont d What is the Downloader speed The normal communication speed via the modem is 2400 baud although it is possible to reduce this to 300 baud Menu C62 When downloading via a direct link the communications speed is set to 115 200 baud Why won t the D3054 Downloader connect to the Panel i The serial port is configured as a printer port Use Menu B70 and ensure that Logging Printer is disabled ii If a D2070 radio module is not fitted configure Menu C40 as disabled then short the reset pins iii The system is communicating or waiting to communicate with the ARC Wait for communications to end or abort the communications by shorting the reset pins D3000 Series Installation Manual D3000 INST O9H v3 17 Control Panel Introduction The D3001 control panel is exactly the same as the D3011 control panel except for the size of its metal case Installation connection and operation are the same regardless of the case size Both of these control panels include a fully monitored 3 Amp power supply The
138. s keypad is also available This unit is enclosed in a case to protect it from physical damage It is fitted with a lead and plug so that it can be plugged in to any control panel or any ADD8 ADD8PSU or ADDR See page 33 An engineer s keypad can be easily converted to a normal keypad so that it can be installed in an alarm system SS Tamper Switch Case back ir ES A knock out I f e a pip beside E pe a a Central Cable Guides ie ae Recommended if j 4 Hinge d g mg z a route of wiring Ecm S sosea Hinge Lid with display and ai keypad hinged down O i ETA LJ Y Fig 31 Keypad case The case clips shut at its top edge and has a hinge on its lower edge It is secured by one screw This design allows the rear of the case to be mounted on a wall while the front hinges down to allow access To open the case hinge up the transparent plastic that covers the display by lifting its bottom right hand corner at the right hand edge of the case See Fig 32 on page 31 A screw will now be visible at the top edge of the case Remove this screw The case may now be prized open by using fingernails not hard implements at the top right hand corner in the narrow slot around the edge of the case Open the lid and it will hinge down See Fig 29 To mount the keypad on a wall first remove the lid which contains all of the circuits and the display to avoid damaging it Remove
139. s will reset the microprocessor in the control panel Use of this pin with the DEFAULT pin will partially or fully delete all programming and return all timers groups areas zone descriptions and log to the factory default values See the D3000 Series Programming Manual LED Indicators Control panels are fitted with several LED indicators These will show correct operation of the board battery faults and in the case of the D3001 and D3011 control panels each of the resettable fuses has a Red LED to indicate when each has tripped All LEDs are described later in this section Printer Programming Port A 9 pin D connector is provided on the circuit board Its use is selected from the control menu An industry standard serial printer may be connected for engineering reports or connected permanently for event logging A suitable serial printer is the D0640 Printers that use parallel port connections may be used when connected via a suitable serial parallel converter Alternatively a PC laptop serial port may be connected for local up downloading using the D3054 programming software Engineers Keypad Socket A socket is provided so that an engineer s keypad can be plugged on to the circuit board while in the engineering mode This aids programming during installation and maintenance when the site keypad s are some distance from the control panel Safety All control panels have an enclosed power supply on the circuit board These enclosures
140. signal strength If reception is poor you should improve the signal strength This may be achieved by repositioning the aerial in an area of stronger signal A 10m aerial extension lead is available to aid repositioning of VDN aerials If there is no radio coverage at the proposed site the radio alarm reporting path using that radio network will not operate Another radio network may provide better signal strength For Vodafone GSM radio signal strength predictions in UK using the postcode of the proposed installation site use the Vodafone Web Site http www vodafone co uk paknet Remember It is always easier to find the point of strongest signal before the equipment is fitted to a wall Moving aerials cables trunking etc after installation is wasted time and effort GSM Signal Strength Testing The most convenient method of GSM aerial location requires the use of a GSM portable telephone to show GSM signal strength The signal strength indicator is normally a bar or line at the side of the display on the portable telephone Note The GSM portable telephone must use the same GSM network as the D2070 Radio Module SIM card uses A portable GSM telephone that uses a different GSM network will not show the correct signal strength There are often two or more separate GSM networks provided by different Service Providers In UK the two GSM networks are operated by Vodafone and Celnet D3000 Series Installation Manual D3000 INST O9H v3
141. sing one screw or bolt at this point Ensure the case is level then mark the position of the two lower mountings Remove the case drill the wall then mount the case using all three mounting points The case and batteries can weigh up to 20 kilogrammes Select suitable mountings Rawl plug fixing into a solid wall using 1 5 inch No10 screws is recommended Re install the circuit board in the control panel case and replace its 2 top fixing screws then tighten all 4 fixing screws Mains Terminal Block Position for optional ADD8 Top Mounting Board Fixings 7 Ah Battery Note Release screw and turn clip to defeat the tamper switch meaa Safety Clip Nl n page Board Fixings Lower Mounting D3001 Control Panel Fig 24 D3000 Series Installation Manual D3000 INST 09H v3 20 D3001 and D3011 Control Panels cont d D3001 11 Installation cont d Polarity of plug on units is shown by Pin 1 or a white triangle The various connections and plug on options to the circuit board are described later in this manual Refer to Fig 27 and 28 and Table 10 Subject Page Number PSTN Digi Modem 69 Plug On GSM Radio Modem 53 Plug On Output Board 56 Plug On Audio Board 57 System Bus Wiring 90 Zone Inputs 98 Tamper Inputs 100 Internal Sounders 101 External Siren Bell and Strobe 102 Programmable Outputs 104 Power Supplies
142. ssing information See Fig 34 and 35 Convert an Engineer s Keypad to a D3202 On occasion when a keypad is required for an installation and none are available it may be convenient to convert an engineer s keypad into a normal D3202 keypad so that it can be installed Simply remove its 4 core cable and plug and the wire that connects its zone 1 input terminal to its output 1 terminal To reassemble an engineer s keypad acquire a new D3202 keypad and refit the wires as shown below An engineer s keypad is exactly the same as a normal D3202 keypad plus It is in a nylon case to protect it It has a 4 core cable and plug for network bus connection A White B Red C Green D Blue See Fig 36 A wire connects its zone 1 input terminal to its output 1 terminal The address switch must be set to 0 The address jumper must be in the 2 and 3 positions address 1 16 White A Green C Engineers Keypad Lead and Plug Fig 36 D3000 Series Installation Manual D3000 INST O9H v3 34 Keypads cont d Audio Helpline Intercom The multimedia keypads include a loudspeaker and microphone These may be used for the audio helpline feature and or for an intercom between keypads Where the intercom and or the audio helpline is required then the audio terminals on the keypad must be connected to the audio terminals on all other multimedia keypads Where the audio helpline is required then the audio bus m
143. t be different from all other ADD8s and ADD8PSUs on the bus The 123 selector next to the rotary address switch must have its jumper in the 23 position See the section on Bus Wiring for further addressing information Tamper Switch The case includes a tamper switch As supplied this is a lid tamper switch only To also allow it to be used as a back tamper switch requires the knock out removing in the rear of the case where the tamper switch activation lever rests See Fig 41 Fit a screw in the wall at this point so that the head protrudes through this knock out and holds the switch in its closed position To adjust turn the screw further into or out of the wall OTA m Rear of Case Wall Tamper Switch Fig 41 Screw fitted in Wall A Side view of Tamper Switch Mains Terminal Block Board Fixings Position for two optional ADD8 Top Mounting 17 Ah Battery i 1 4 i oo So ie 4 j i i Tamper Switch re re er oer re mE a Se i A Lower Mounting Lower Mountin eo D g Board Fixings 17 Ah Battery D3510 ADD8PSU Fig 42 D3000 Series Installation Manual D3000 INST 09H v3 40 ADD8PSU cont d Tripped Fuse LED Power Mains Supply Battery Reverse Polarity Kickstart for Aux 1 O P Supply connector Terminals Battery LED Pins Programmable Oupus Mains ly LED Internal Sounder Supply Output Tripped Fuse LED 12 volt healthy LED for Intern
144. t the whole system press A OK then A OK Alternatively to default the hardware data only press the down arrow key until the top line reads Hardware and press the flip key then press OK OK Then panel will reset the appropriate data and learn the devices connected to the network ii Change the address of the keypad to 1 Open the keypad and turn the rotary address switch so the arrow points to 1 Ensure that the jumper link next to the rotary address switch connects positions 2 and 3 Why do the Green and Red LEDs above the ABCD keys keep going out The green LED indicates that the appropriate group s are ready to set whereas the red LED indicates that the appropriate group s are set These LEDs go out after 30 seconds to ensure that the system complies with the ABI guidelines which dictate that it shall not be possible to ascertain whether the system is set or unset by looking at the keypad It is possible to override this using menu D28 What are the ABCD keys for These are Quickset keys that allow the user to set groups effectively part setting the system On the D3001 it is possible to define a combination of groups which can be set or unset when the appropriate button is pressed On the D3021 or D3022 A group 1 B group 2 C group 3 and D group 4 have connected an additional keypad to my system but the display reads Bus Fail Use Menu C90 to learn the new keypad onto the system and update
145. tandard It can carry up to 30 simultaneous telephone calls This type of digital telephone line normally connects directly to a PABX telephone exchange Note that the D0700 ISDN analogue converter is for ISDN2 lines not ISDN30 The control panel cannot be directly connected to a digital telephone line D3000 Series Installation Manual D3000 INST O9H v3 71 ADSL Asynchronous Digital Subscriber Line Broadband Filter When an analogue PSTN telephone line also carries ADSL broadband signals and it is used by a security system e g control panel Dualcom DigiCom a security ADSL filter MUST be used A filter is used to separate the analogue telephone signals from the ADSL broadband digital data signals because the telephone or security system may be disrupted or completely inhibited if ADSL broadband digital data is allowed into them from the telephone line The D0730 security ADSL Filter is designed specifically for use with security systems It includes spare terminals to aid wiring that are labelled Erceisys Pass Through This item meets all of the requirements of the British and European telephone safety and security standards See Fig 80 Other types of filter and plug in filters should not be used for series connection of a security system to the telephone line These types are for Use with telephones fax machines etc Plug in filters are available from the Telephone Service Provider and many electrica
146. tectors and other equipment Each of these outputs is protected by a fuse that will automatically reset and an indicator LED to show if the fuse has tripped To reset the fuse disconnect everything from the output and wait 30 seconds Repair the fault and reconnect to the output The D3021 and D3022 control panels have 2 auxiliary power outputs with a total capacity of 1 amp and has no fuse LED indicator The keypads and ADD8s each have one or more auxiliary power outputs that are not fused tas Max output Auxiliary Power Outputs current Fuse LED Note D3001 and D3011 Control Panels Auxiliary 12 volt output 1 1 Amp Yes Yes Auxiliary 12 volt output 2 1 Amp Yes Yes Auxiliary 12 volt output 3 1 Amp Yes Yes D3021 and D3022 Control Panels Auxiliary 12 volt output 1 o p 1 o p 2 Yes No Auxiliary 12 volt output 2 1 Amp D3500 and D3510 ADD8PSUs Auxiliary 12 volt output 1 1 Amp Yes Yes Auxiliary 12 volt output 2 1 Amp Yes Yes Auxiliary 12 volt output 3 1 Amp Yes Yes D3300 ADD8 o p 1 0 p2 No No See note Auxiliary 12 volt output 1 2 amp 3 o p 3 750mA below D3201 and D3202 Keypads See note Auxiliary 12 volt output Toomi Ne ne below No outputs on D3301 ADD R 0 No Ne this device Table 54 Note Any current taken from the auxiliary power outputs on the ADD8 or keypad has to flow along the bus wiring from the power supply in the control panel or from an ADD8PSU A voltage drop will b
147. ternal Sounders and their total impedance varies for each item See Table 45 Fig 101 and 102 Max max 16 ohm al Load Fuse LED Speakers D3001 D3011 Control 4 ohms Yes Yes 4 Panel D3021 D3022 Control 4 ohms Yes No 4 Panel D3201 D3202 Keypad 16 ohms No No 1 D3300 ADD 8 16 ohms No No 1 D3500 D3510 ADD8PSU 4 ohms Yes Yes 4 Table 45 Current Consumption Each 16 ohm internal sounder will consume 400mA of current when it is making its loudest tone Use this figure when calculating voltage drops on wiring Only one 16 ohm Sounder on One 16 ohm Keypads amp ADD8 Soundi sounder Fig 101 Up to four 16 ohm Sounders on Four 160hm Control Pane amp ADD8PSU Sounder sounders Fig 102 D3000 Series Installation Manual D3000 INST O9H v3 85 Siren Bell and Strobe Connections The control panels and the ADD8PSU have outputs for connection to SAB and SCB bell sounder and strobe units These connections plus the programmable options are universal and suitable for all types of SAB and SCB bell sounder and strobe units Connection details are shown in Fig 103 104 and 105 The BELL terminal is the 12 volt supply nominal 13 8 volts to the SAB and SCB unit for certain export markets this output is set to 14 4 volts The BELL terminal and the RTN terminal are a Ov connection The BELL output is protected by a 1 Amp auto reset fuse On the D3001 and D3011 control panels there is an
148. the battery s Calculating the current available while a flat battery is recharging 1 Calculate the current required to recharge the battery within the specified time Call this value 2 Read the maximum current available from the power supply specifications Call this value M 3 Subtract A from M This is the maximum current that can be drawn from the power supply while the battery is recharging Battery and Power Supply Standards To meet user insurer industry and or national requirements a standard of installation and or operation should be complied with Several standards define the time that equipment must operate on batteries and the above calculations are detailed below for 3 of these standards PD6662 Grade 2 requires a 12 hour battery life with recharging within 72 hours PD6662 Grade 3 requires a 12 hour battery life 24 hours if Mains Failure is not sent to the ARC with recharging within 24 hours EN 50131 1 Grade 2 requires a 12 hour battery life with recharging within 72 hours EN 50131 1 Grade 3 requires a 30 hour battery life 60 hours if Mains Failure is not sent to the ARC with recharging within 24 hours British Standards BS4737 requires an 8 hour battery life with recharging within 24 hours D3000 Series Installation Manual D3000 INST 09H v3 92 Auxiliary Power Outputs The D3001 and D3011 control panels and ADD8PSUs each have 3 auxiliary power outputs There are to provide power to de
149. the hardware fitted list then use Menu C91 to update the hardware required list How do I program a tag onto the system Add a user onto the system as normal When the user s menu options have been set the display will read Waiting for tag Present the tag to the reader and it will be learned in Note that tags can only be used on systems fitted with software version 3 005 or later and must use either D3202 or D3212 keypads What does the warning Devices Required Fault mean Menu C90 Hardware Fitted tells the system what devices are actually fitted Menu C92 Hardware Required tells the system what should be fitted This can be different to the Hardware Fitted list to allow zones to be programmed even though the appropriate Add8s are not yet connected The Devices required Fault warning indicates that these two lists do not match If this has been done deliberately press OK to accept the warning e g you may be revisiting site tomorrow to connect the remaining Add8s Otherwise use Menu C91 to copy the Hardware Fitted list into the Hardware Required list Can the end user reset alarms with the tag Presenting a tag to the reader does the same as entering the users PIN code OK If the system is unset this will start to set the user s autogroups If the system is set this will unset the user s autogroups If there has been an alarm condition the tag will only reset user resettable condition
150. the low voltage threshold Refer to Appendix 3 Transmission Details Refer to Appendix 3 Supervision Radio Signals Range Expectations Refer to Appendix 3 Range Expectations Battery Replacement The PIR movement detector will transmit a low battery signal to the control panel when the low battery voltage threshold is reached This signal will be sent before the batteries are fully discharged and the detector operation ceases Replace batteries with good quality alkaline cells when the low battery warning if first transmitted Refer to Appendix 3 Batteries D3000 Series Installation Manual D3000 INST O9H v3 56 Wire free Detectors cont d D4811 Door Contact Universal Transmitter Manufacture marking DC 8L or DC 9L Installation 1 2 Loosen the single screw on the end of the door contact universal transmitter and remove the back plate 3 Fit the batteries in their holder 4 Fit the test jumper in the ON position 5 Learn in the door contact universal transmitter to the receiver or control panel by pressing the test button you may need to hold this in for several seconds 6 To use the built in magnetic switch connect links across the tamper and alarm terminals and ensure that the magnetic switch jumper is in the Parked position Alternatively to use the alarm and tamper inputs connect normally closed loops and switches to the terminal blocks and ensure that the magnetic switch jumper
151. ting holes are provided in the D3001 and D3011 cases and push in mounting pillars are supplied in the fitting kit One ADD8 may be fitted in the D3001 One or two ADD8s may be fitted in the D3011 This product has many connection and programmable options It is strongly recommended that the site survey and the Installation Instructions are followed when specifying and installing this equipment D3000 Series Installation Manual D3000 INST O9H v3 18 Control Panel cont d This page covers items common to all control panels See Fig 33 34 and 38 for the layout of the D3001 D3011 D3021 and D3022 control panel boards Termination The control panel bus is a straight line bus not star or ring wired If the control panel is connected at one of the ends of the bus a jumper link must be fitted to the TERM selector pins If the control panel is connected at any other position on the bus a jumper link must not be fitted to the TERM selector pins park it on one of the two pins The D3001 and D3011 control panels have two bus connections The D3021 and the D3022 control panels have one network connection See section on network wiring for further information on addressing Kick Start The KICKSTART pins will switch the control panel on or off when running on batteries only mains disconnected Their operation is fully described later in this manual Refer to section Power Supplies and Batteries Reset The RESET pin
152. to be below 10 5 volts you must reduce the voltage drop Reducing the voltage drop This can be achieved by the use of thicker wires or using several thin wires together and or placing power supplies nearer to the units that require the current Method 1 Use more cores The voltage drop in the examples above was 2 2 volts By using 2 cores in parallel for the A and the B wires will reduce the voltage drop to 1 1 volts By using 4 cores in parallel for the A and the B wires will reduce the voltage drop to 0 55 volts See Fig 90 Parallel wires ADD Keypad The voltage drop in the examples above was 2 2 volts By using 2 cores in parallel for the Aand the B A AA wires will reduce the voltage drop to 1 1 volts By ie Xs 8 using 4 cores in parallel for the A and the B wires c cc d will reduce the voltage drop to 0 55 volts D a DD m gt am 275MA ie 155MA 105MA Fig 90 Reduced Voltage Drop Example To detectors Method 2 Install a Power Supply By installing an additional ADD8PSU power supply closer to the equipment that is using the current means shorter wiring and less voltage drop An additional power supply with its batteries also means more current is available for the alarm system plus an increased battery standby time See Fig 91 Refer to the section on the ADD8PSU for full connection information The voltage drop in the examples above was 2 2 volts By using an additional power supply ADD8PSU
153. to power the detectors and other devices Up to 12 ADD8PSUs or ADD8s may be connected to the bus The ADD8PSU is supplied with a fitting kit that includes all required screws EOL resistors fuses etc The ADD8PSU measures 400 x 400 x 115mm h x w x d and has space to accommodate one or two 17Ah batteries size 170 x 180 x 80mm h x w x d or up to four 7 Ah batteries Refer to the section on power supplies and batteries to determine the batteries required for the system The case stands away from the wall by 12mm There are multiple cable entry points on the rear of the case and sufficient space behind the case for cables There are also cable knock outs on the top and bottom of the case Supplied cable entries have smooth edges but knock out holes do not Use of grommets is recommended and may be required by installation standards Cable ties should be used at the cable tie points to secure cables where they enter the case Where only one battery space is used the upper space can be used to mount one or two additional ADD8s Mounting holes are provided and push in mounting pillars are supplied in the fitting kit Installation The lid of the ADD8PSU is secured by 4 screws To open the case remove these screws then remove the lid Note how the lid fits into the back of the case To mount the ADD8PSU on a wall first remove the circuit board to avoid damaging it Remove the 2 top screws holding the circuit board loosen the two lower screws
154. tted to the TERM pins When the TERM jumper is not used park it on one of the two pins See section on bus wiring for further information on addressing Tamper Bus Address RESET Switch Selector Switch pins amp Jumper Link TERM Not Used Jumper Link Fig 40 Engineers Keypad Factory Service Internal sounder Tamper Switch Connector Connector Volume control Shunt Jumper D3300 ADO8 Circuit Poard D3000 Series Installation Manual D3000 INST 09H v3 37 ADD8 cont d Engineers Keypad A socket is provided so that an engineer s keypad can be plugged in the circuit board while in the engineering mode D3001 and D3011 only See Fig 40 Shunting the Tamper Switch s The SHUNT selector will bypass the tamper circuit Remove the jumper link or park it on one of the two pins for normal tamper switch operation Fit the jumper link to the two pins for ADD8 operation with the lid open Closing the lid with the shunt link in the shunted position will stop an exit from engineering mode and a warning message will be displayed on keypads See Fig 40 Reset The RST pins reset the microprocessor in the keypad Use of these pins is not required during normal set up or operation See Fig 40 Power Consumption The bus supply must be 10 volts or greater Refer to Appendix 4 for the current consumption of all units Note that an internal sounder if connected will require an additional 400mA Use these figures when calculat
155. udes a small rechargeable battery that is charged by power from typically an alarm control panel The bell will ring using power supplied from that panel The unit s small battery will operate the bell in the event that the wiring from the alarm control panel is cut SAB units are normally for low average power bells or sirens SCB Self Contained Bell SCB refers to the type of control circuits in a bell siren unit The unit includes a large rechargeable battery that is charged by power from typically an alarm control panel The bell will ring using power supplied from the unit s internal battery when commanded by the panel The unit s battery will also operate the bell in the event that the wiring from the alarm control panel is cut SCB units are normally for high power bells or sirens D3000 Series Installation Manual D3000 INST O9H v3 108 APPENDIX 7 cont d Glossary of Terms cont d SIA Security Industry of America Alarm Reporting Protocol A serial data alarm reporting protocol used to send via an analogue PSTN telephone network a transmission to receiving equipment at an ARC and to receive checking and acknowledgement replies from that receiving equipment The SIA protocol is commonly used in burglar or intrusion alarm equipment See also digital SIA SIM Card Subscriber Identification Module Card A card or chip that contains data for use by a unit that communicates via the GSM network e g a portable te
156. uit Board Knockout Height pip Side view of Tamper Switch Fig 33 Tamper Switch The case includes a tamper switch As supplied this is a lid tamper switch only To also allow it to be used as a back tamper switch requires the knock out removing in the rear of the case where the switch activation lever rests This knock out has a semi circular moulding on it and a small pip beside it See Fig 31 and 33 Remove the knock out and semi circular moulding Fit a screw in the wall at this point so that the head protrudes through this knock out into the case and holds the switch in its closed position To adjust turn the screw further into or out of the wall until its height from the case rear is the same as the pip D3000 Series Installation Manual D3000 INST O9H v3 31 Keypads cont d Bus Address Programmable Selector Switch Internal Sounder outputs amp Jumper Link output Zone 1 4 inputs 12 volt output Bus terminals ee GTTTOO Audio bus RESET e terminals pins a g TERM Tamper a Jumper Link Switch ai Factory Service Connector Tamper Switch A N Display Backlight Shunt DIM Jumper Link Jumper D3201 Mk1 Keypad Circuit Board Fig 34 Programmable Bus Address aint Selector Switch Internal Sounder 12 volt output amp Jumper Link output Bus terminals ees Tamper Switch T a Shunt Jumper ai oN TERM Jumper Link Zone 1 4inputs m noa Display Backli
157. ust also be connected to the audio terminals on the optional plug on audio board that is fitted to the control panel See the audio bus on page 86 for connection details Multi Media Keypad d Control Panel ae optional plug On H a Oe Audio Board sa SQ boocdsancsaadscccccsduvcdeddpecesesa 8999 Typical Wiring of Audio Bus Fig 37 D3000 Series Installation Manual D3000 INST O9H v3 35 ADD8 The D3300 ADD8 enables 8 detectors to be connected on FSL loops to the bus In addition there are 4 fully programmable outputs an output for an internal sounder and 12 volts output to power the detectors Up to 13 ADD8s or D3500 ADD8 PSUs may be connected to the D3001 or D3011 control panel bus Up to 2 ADD8s may be connected to the D3021 control panel bus and up to 4 ADD8s may be connected to the D3022 control panel bus An ADD8 is supplied with a fitting kit that includes all required EOL resistors etc An ADD8 measures 168 x 108 x 35mm h x w x d The case mounts directly onto a wall or any surface using any of the multiple mounting holes in the rear of the case There are multiple cable entry points on the rear of the case and cable knock outs on the top bottom and sides of the case See Fig 38 Break outs BackTamper Switch Break outs adjustment Screw Catch to J Catch to release board release board 000209 gogogo Bi eacos lf Sonaaoee e 25 a ra Board 8reak o
158. ust operate on batteries and the battery recharge time See battery and power supply standards below D3000 Series Installation Manual D3000 INST O9H v3 90 Power Supplies and Batteries continued Table 50 shows the life in hours for different batteries that are discharging at different currents in amps Battery Discharge 1 x 7Amp hour 2 x 7Amp hour 1 x 17Amp hour 2 x 17Amp hour Current Battery Batteries Battery Batteries 100 mA 64 hours 128 hours 154 hours 308 hours 200 mA 32 hours 64 hours 77 hours 154 hours 300 mA 21 hours 42 hours 51 hours 102 hours 400 mA 16 hours 32 hours 39 hours 78 hours 500 mA 13 hours 26 hours 31 hours 62 hours 600 mA 11 hours 21 hours 26 hours 52 hours 700 mA 9 hours 18 hours 22 hours 44 hours 800 mA 8 hours 16 hours 19 hours 38 hours 900 mA 7 hours 14 hours 17 hours 34 hours 1 0A 6 3 hours 12 5 hours 15 5 hours 31 hours 1 2A 5 3 hours 10 6 hours 13 hours 26 hours 14A 4 5 hours 9 hours 11 hours 22 hours 1 6A 4 hours 8 hours 9 6 hours 19 2 hours 1 8A 3 5 hours 7 hours 8 5 hours 17 hours 2 0A 3 2 hours 6 4 hours 7 7 hours 15 5 hours 2 2A 2 9 hours 5 7 hours 7 hours 14 hours 2 4 A 2 6 hours 5 2 hours 6 4 hours 12 8 hours 2 6 A 2 4 hours 4 8 hours 5 9 hours 11 8 hours 2 8 A 2 3 hours 4 5 hours 5 3 hours 10 6 hours 3 0 A 2 1 hours 4 2 hours 5 1 hours 10 2 hours Table 50 Tables 51 and 52 shows the current in Amps that
159. uts Securing Screw Break outs ADDS Bus Expansion Module Fig 38 Installation The case clips shut and is secured by two screws To open the case remove the two screws from the lid The case may now be opened by using fingers to pull the lid off To mount the ADD8 on a wall first remove the lid Remove the securing screw from the centre of the circuit board and then unclip the circuit board by releasing the 2 white plastic catches next to the Zone terminals See Fig 38 Mark the position of the selected case mounting holes Drill the wall Break out the selected cable entry point s then mount the case ensuring that it is level The break outs on the ends of the case may be opened by inserting a terminal screwdriver into the slot at the end of the knock out and twisting Re install the circuit board in the ADD8 case Replace the board securing screw When the case back is mounted to the wall and the cables have been brought into the case the outer sleeve of cables should be removed where they enter the case Always tie wrap cables to the cable guides before connecting them to the terminals The various connections are described later in this manual Refer to sections Subject Page Number System Bus Wiring 90 Zone Inputs 98 Internal Sounders 101 Programmable Outputs 104 Table 20 D3000 Series Installation Manual D3000 INST O9H v3 36 ADD8 cont d Tamper Switches The case includes 2 tamper switc
160. v supply when the STR terminal is switched to Ov In this example the strobe must not draw more than 500mA maximum current D3000 Series Installation Manual D3000 INST O9H v3 87 Programmable Outputs The D3000 Series control panels keypads ADD8 and ADD8PSU have fully programmable outputs These outputs may operate relays and contactors for control of motors lighting magnets etc They can trigger camera systems and other equipment 12 volt low current sounders and lights can be driven directly from the outputs These outputs may be clean contacts on a relay or switching transistors The table below lists which outputs are on which unit Fig 106 Fig 107 Fig 108 Relay output The relay will be normally de energised and the contacts will switch up to 24 volts at 1 Amp See Fig 106 There are two types of transistor output One can switch up to 500mA to 0 volts There is a 2200 ohm resistor to 12 volts See Fig 107 The other can switch up to 100mA to 0 volts There is a 2200 ohm resistor to 12 volts See Fig 108 Refer to the D3000 Series programming manual for more than 70 different programmable output types which control when and how these outputs will operate Transistor Programmable ene bal Output See Transistor Output See Fig 123 Outputs g Fig 122 Maximum Output Current 1 Amp 100 mA 500 mA D3001 Control Panel Output 1 Output 2 Output 3
161. ximum Fig 86 System bus wiring should follow the straight line rule See Fig 81 82 86 and 87 Star wiring schemes may operate if wiring is kept short e g less than 20 metres See Fig 88 Star wiring schemes are not recommended because their use may result in incorrect operation Ring wiring schemes must not be used Where possible keep system bus wiring apart from other cables and wiring including mains telephone and computer cabling internal speaker and sounder wiring The control panel may be connected at the end of the system bus or at any point along its length See Fig 86 and 87 The control panels and the ADD8PSU each supply 12 volts power to the system bus The system bus A terminal 12v is protected by a one amp fuse that will automatically reset and an indicator LED where fitted to show if the fuse has tripped Keypad ADD Control ADD term term gs ih UO SS se Mides Pr wes S008 Fig 87 D3000 Series Installation Manual D3000 INST O9H v3 76 System Bus Wiring cont d Star Wiring iii not recommended M Fig 88 B c D If the current on the system bus A terminal exceeds the maximum current the fuse will trip and where fitted the associated red LED will illuminate The fuse will remain in the tripped state and the LED will remain lit until the load on that output is removed To reset the fuse disconnect everything from that output a
162. y Open Detectors Detectors usually have outputs that are normally closed and the wiring options are shown above Detectors with normally open outputs e g a pressure mat can also be connected as shown but the programming for that zone input must be Inverted Refer to the programming manual Exit Terminate Buttons When a zone input is used for the connection of an exit terminate button then it must be wired as a FSL Input See Fig 94 Where an exit terminate button is normally open then the zone input must be Inverted Refer to the programming manual Key Switch Connection When a zone input is used for the connection of a key switch for key switch setting and unsetting then it must be wired as a FSL input See Fig 94 Where a key switch is normally open then the zone input must be Inverted Refer to the programming manual Two Door Contacts on One Zone Input Wiring more than one contact on an input zone is often required on double doors See Fig 97 Two movement detectors on a single zone is NOT recommended 4700 ohms All yellow or yellow purple red Drtesirr l Derector 7 A ee sak S Targi Tamper 2200 ohms All red or redredred 4700 ohms All yellow or yellow purple red Double Contacts Fig 97 D3000 Series Installation Manual D3000 INST O9H v3 83 Tamper Inputs The control panels and ADD8PSUs have tamper inputs for tamper switch connection
163. y one of a similar type and rating When closing the case ensure that no wires are trapped between the back and lid or trapped around the tamper switch Ensure that the safety earth wire is fitted from the case back to the push on connector on the lid Do not use longer screws that those provided when securing the lid to avoid damage to internal batteries or wiring D3000 Series Installation Manual D3000 INST O9H v3 43 ADD R When the ADD R is used with the D3001 and D3011 control panels each ADD R can receive transmissions from any of the 64 wireless detectors that can be used with the system When the ADD R is used with the D3021 control panel each ADD R can receive transmissions from up to 16 wireless detectors The ADD R cannot be used with the D3022 Each ADD R can receive signals from any or all of the wireless detectors in that system ADD Rs have no wired zone inputs programmable outputs sounder outputs or auxiliary power outputs An ADD R and 12 volt battery can be used to survey a site for placement of short range detectors The open ground range of the wire free detectors is in excess of 200 metres Within buildings the range will be less because the radio signals will be attenuated by walls and most items within buildings To provide coverage on larger sites more ADD Rs may be installed Up to eight ADD Rs can be connected to the D3001 11 control panels Up to two ADD Rs can be connected to the D3021 control
Download Pdf Manuals
Related Search
Related Contents
Instruções de operação - ProMinent Dosiertechnik GmbH PHOTO BRIEFING - Extranet National Highway Sector Scheme for C++ : Leçon 14 Privilèges d`accès, this et amitié RH850 Debug - Renesas Electronics 放射線量の計測・除染作業を強力にサポートします。 311179j Ultra Max II 695/795/1095/1595 Mark V Repair User`s Manual ジュピター施工・取扱説明書(pdf) Moen T3111 User's Manual Copyright © All rights reserved.