Home

RADIOBAND SYSTEM INSTALLATION MANUAL

image

Contents

1. rump 4 8 Installation on one leafed sliding door with control panel and RADIOBAND RU C Prox Quantek Systems www quantek co uk 4 9 installation on sliding door with control panel and RADIOBAND RC RCS card connector 4 10 Installation on guillotine door with control panel and RADIOBAND RU umi C Prox Quantek Systems www quantek co uk 9 CONTROL PANEL DIAGRAM FOR CONNECTION TO THE RADIOBAND SYSTEM SINGLE PHASE PANELS JCM Control Applications panels START EU RESIDENT DCS ROLLER MOTION BASIC EU MAIN 1T EU Rollerfor residential and commercial use Roller for residential use Roller for residential and commercial use Slidingfor residential and community use Swing folding Semi automatic and Compatibility with Radioband system RADIOBAND RU with external power supply RADIOBAND RU RADIOBAND RU with external power supply RADIOBAND RU RADIOBAND RU Semi automatic operations 433 or 868 MHz radio card connection Start button and safety edge connection Semi automatic and automatic operations Built in 433 MHz receiver Start stop button connection limit switches and security contact on close Possible to connect the TBAND card 24Vac outlet Garagelightcontact
2. is activated or if there is an error in its operation the receiver activates the output relay MANUAL PROGRAMMING RADIOBAND RU makes it possible to store 6 RADIOBAND TAs and or RADIOBAND TBXs 3 on Relay 1 and 3 on Relay 2 Press the receiver programming PROG button for 1s a sound signal will be heard The receiver will go into programming the first relay If the programming button is kept pressed the receiver will go into programming the second relay moving cyclically from one really to another Once the programming relay has been chosen for the transmitter you want to start using send the programming code by pressing the transmitter Every time a transmitter is programmed the receiver will emit a sound signal for 0 5s If 10 seconds pass without programming the receiver will go out of programming mode emitting two 1s sound signals If when programming a transmitter the receiver s memory is full it will emit 7 sound signals lasting 0 5s and come out of programming Note For aright operation of the system the transmitter has to be programmed in one receiver only RADIOBAND TA RADIOBAND TBX replacement In case you need to replace a RADIOBAND TA or a RADIOBAND TBX it is necessary to reset the system see TOTAL RESET on next page and reprogram all RADIOBAND TA and or RADIOBAND TBX used in the installation SYSTEM CHECK This function has to be used to check the operation and range of all the devices oncethe installation has been
3. 2 Number of relays Power supply 12 24V AC DC Power supply range 9 35V DC 8 28V AC Relay contacts Consumption idle op Self test input Power Op temperature Seal Box size Range guaranteed C Prox Quantek Systems www quantek co uk INSTALLATION AND CONNECTIONS Fix the back of the box to the wall using the wall plugs and screws supplied Install the receiver close to the door and avoid metal surfaces between the receiver and the transmitter Pass the cables through the bottom of the receiver Connect the power cables to the terminals of the printed circuit following the indications of the connections diagram Store RADIOBAND TA and or RADIOBAND TBX Fix the front of the receiver to the back with the screws supplied forthe purpose 1 Power supply 12 24V AC DC 2 Power supply 12 24V AC DC 3 4 R1 Connection to the safety band input of the control panel resistive contact 8 2kQ with jumper in position BS1 see CONNECTIONS Figure 1 Or to the control panel safety contact input NC with jumper in position CS1 see CONNECTION Figure 2 5 6 R2 Connection to a second safety band input of the control panel resistive contact 8 2kQ with jumper in position BS2 Or to the control panel safety contact input NC with jumper in position CS2 7 AUTOTEST Common connection safety self test See CONNECTIONS Figure 3 and table POLARIZED SELF TEST 8 AUTOTEST Self test connection for R1 See CONNECTION
4. Dead man operations using GO BUTTON or GO SWITCH semi automatic Built in 868 MHz receiver Start button and safety edge connection Semi automatic and automatic operations 433 or 868 MHz radio card connector Start pedestrian and stop button connection Limit switch safety edge and security contact connection Garage light contact 12Vdc outlet and sliding for automatic operations residential and 433 or 868 MHz community use radio card connector Start and stop button connection Limit switch safety edgeand security contact connection Traffic light or signal card connector Garagelightcontact 24Vac outlet Electro lockconnection MAIN 2T EU Same as Same as MAIN 1T EU RADIOBAND RU MAIN 1T EU for2 motors C Prox Quantek Systems www quantek co uk ADVANCE STANDARD 1T EU STANDARD 2T EU Swing folding Semi automatic and and sliding for residential and intensive use Digital programming Gentlestop RADIOBAND and otherforcelimiting device FORCELIMIT and T HALL connector 433 or 868 MHz card connector Startand stop button connection Limit switch Limit switch safety edge and security contact connection Electro lock connection Traffic light card or signal card connector Garagelightcontact 24Vac outlet Auto test outlet Semi automatic and Swing folding and sliding for residential and community use Gentle stop 433 or 868 MHz
5. carried out Press the receiver s CHECK button for at least 1 second to enter check mode The indicator light will come on and four beeps will be heard Perform a complete door opening and closing manoeuvre During the system check a beep will be heard every 1 5 seconds CORRECT OPERATION OF THE SYSTEM If no other acoustic signal is heard on completing the manoeuvre the system is operating correctly Either press the CHECK button again or wait 5 minutes and the C Prox Quantek Systems www quantek co uk RADIOBAND RU will exit checking automatically indicating with two beeps that the check has been correct The check indicator light will go out DETECTION OF BAND FAILURE If the communication with a RADIOBAND TA or a RADIOBAND TBX fails during checking or the communication is deficient for instance too many communication retries or poor coverage the RADIOBAND RU emits three consecutive beeps indicating that an error has occurred Halt the door manoeuvre and press the safety bands installed to detect what has failed fa single beep is heard on pressing a band this means that the band is correct If three consecutive beeps are heard on pressing the band this means that the band has failed In this event it is recommended changing the orientation of the transmitting receiving aerials or installing an AED 868 or FLAT 868 outdoor aerial to ensure the desired range On exiting check mode seven consecutive beeps will be heard and
6. the indicator light will flash continuously Perform another system check until the result is correct Signal coverage After pressing one of the installed bands continuous flashes ranging from 1 to 5 indicate the signal coverage for this band at the time it was pressed Number of check LED Coverage Result of check flashes Band failure Very good TOTAL RESET In programming mode keep the programming PROG button pressed down and make a bridge with the MR reset jumper for 3s The receiver will emit 10 warning sound signals and then more at a faster frequency indicating that the operation has been carried out The receiver will stay in programming mode If 10 seconds elapse without programming or if you press the programming button quickly the receiver will go out of programming mode emitting two 1s sound Signals TRANSMITTER BATTERY LOW INDICATOR RADIOBAND TA RADIOBAND TBX If the battery of a transmitter programmed into the receiver becomes low it will give out 4 short signals every 20 seconds If there is more than one transmitter programmed the safety band must be activated to check whether the receiver then makes these 4 short signals If this is the case the transmitter connected to the activated safety band will be the one with the low battery Change it C Prox Quantek Systems www quantek co uk INSTALLATION ADVICE The transmitter and receiver antenna must be parallel to each other for optimum signal
7. DIOBAND TBXs 3 on Relay 1 and 3 on Relay 2 Press the receiver programming PROG button for 1s a sound signal will be heard The receiver will enter safety band closing programming mode BSC If the programming button is kept pressed the receiver will enter safety band opening programming mode BSO moving cyclically from one really to another Once the programming relay has been chosen for the transmitter you want to start using send the programming code by pressing the transmitter Every time a transmitter is programmed the receiver will emit a sound signal for 0 5s If 10 seconds pass without programming the receiver will go out of programming mode emitting two 1s sound signals If when programming a transmitter the receiver s memory is full it will emit 7 sound signals lasting 0 5s and come out of programming Note For a right operation of the system the transmitter has to be programmed in one receiver only RADIOBAND TA RADIOBAND TBX replacement In case you need to replace a RADIOBAND TA or a RADIOBAND TBX it is necessary to reset the system see TOTAL RESET on next page and reprogram all RADIOBAND TA and or RADIOBAND TBX used in the installation SYSTEM CHECK This function has to be used to check the operation and range of all the devices once the installation has been carried out Press the receiver s CHECK button for at least one second to enter check mode The indicator light will come on and four beeps will be heard
8. Perform a complete door opening and closing manoeuvre During the system check a beep will be heard every 1 5 seconds CORRECT OPERATION OF THE SYSTEM C Prox Quantek Systems www quantek co uk If no other acoustic signal is heard on completing the manoeuvre the system is operating correctly Either press the CHECK button again or wait 5 minutes and the RADIOBAND RC RCS will exit checking automatically indicating with two beeps that the check has been correct The check indicator light will go out DETECTION OF BAND FAILURE If the communication with a RADIOBAND TA or a RADIOBAND TBX fails during checking or the communication is deficient for instance too many communication retries or poor coverage the RADIOBAND RC RCS emits three consecutive beeps indicating that an error has occurred Halt the door manoeuvre and press the safety bands installed to detect what has failed fa single beep is heard on pressing a band this means that the band is correct If three consecutive beeps are heard on pressing the band this means that the band has failed In this event it is recommended changing the orientation of the transmitting receiving aerials or installing an AED 868 or FLAT 868 outdoor aerial to ensure the desired range On exiting check mode seven consecutive beeps will be heard and the indicator light will flash continuously Perform another system check until the result is correct Signal coverage After pressing one of the
9. RADIOBAND SYSTEMINSTALLATION MANUAL C Prox Quantek Systems www quantek co uk CONTENTS CONTENTO Lm 2 1 INTRODUCTION T 3 Lob System segale cele 3 1 2 Normative requirements eese esee esee ie reni riore nio ionici necionecionee 3 5 2 1 RADIOBAND TA RADIOBAND TBX i 5 ZZ RADIOBAND Rissa 8 ZO RADIOBAND RGRES ore 15 3 AUTO TEST FUNCHON m 19 JUI AUTO TEST DESCRIPTION cloni 19 3 2 RADIOBAND RCS CONNECTIONS ene 20 4 RADIOBAND SYSTEM INSTALLATION RECOMMENDATIONS 21 4 1 Installation on roller door with control panel and RADIOBAND RU 21 4 2 Installation on two leafed swing door with control panel and RADIOBAND RCORGCS Usati tm DeuSuti ive Ia dis cas sc AER DUE LS que USO 21 4 3 Installation on horizontal sectional door with control panel and NADIOBAND Uns 22 4 4 Installation on angled sectional door with control panel and RADIOBAND 22 4 5 Installation on stackable sectional door with control panel and RADIOBAND RU erede o 23 4 6 Installation on one leafed residential folding door with control panel with RADIOBAND RC RCS card connector eese 23 4 7 Installation on one leafed folding door for communities with control panel and RADIOBAND RUL sanas 24 4 8 Installation on one leafed sliding
10. S Figure 3 and table POLARIZED AUTO TEST 9 AUTOTEST Self test connection for R2 See CONNECTIONS Figure 3 and table POLARIZED AUTO TEST POLARIZED AUTO TEST Check the auto test output on the control panel in standby to see whether the voltage is OV inverted test input or 12 24V AC DC positive polarity The auto test signal of the panel must remain at its maximum for 2 seconds Autotest Autotest Polarity Jumper ATEST1 ATEST2 outputin output type ATEST POL standby activated Connection to a OV 12 24V Positive nee equipment with autotest m ull don Connecte Connecte d d Connection to a No No equipment without connected connected autotest N B Only connect the auto test output to be used Where the auto test is not used the system is not checked at the start of the operation which means that security normative EN 12453 regarding the use of motorised garage doors is in some cases not complied with C Prox Quantek Systems www quantek co uk LIGHT INDICATORS RADIOBAND R In operation In programming U RC RCS Relay 1 LED Normally off On Indicates the channel to be Indicates the status of the relay output programmed If R1 is not connected on Relay 2 LED Normally off On Indicates the channel to be Indicates the status of the relay output programmed If R2 is not connected on OPERATION The receiver checks that all the programmed bands are working properly If a band
11. S2 Outlet 2 Radioband activation 5 5Vdc power supply 6 RB AT 1 Inlet 1 Radioband auto test 7 Not connected 8 RB AT 2 Inlet 2 Radioband auto test C Prox Quantek Systems www quantek co uk 4 RADIOBAND SYSTEMINSTALLATION RECOMMENDATIONS 4 1 Installation on roller door with control panel and RADIOBAND RU 4 2 Installation on two leafed swing door with control panel and RADIOBAND RC RCS C Prox Quantek Systems www quantek co uk 4 3 Installation on horizontal sectional door with control panel and RADIOBAND RU 4 4 Installation on angled sectional door with control panel and RADIOBAND RU C Prox Quantek Systems www quantek co uk 4 5 Installation on stackable sectional door with control panel and RADIOBAND RU CIONI 4 6 Installation on one leafed residential folding door with control panel with RADIOBAND RC RCS card connector C Prox Quantek Systems www quantek co uk 4 7 Installation on one leafed folding door for communities with control panel and RADIOBAND RU
12. automatic operations 433 with positive sliding and or 868 MHz radio card polarisation auto guillotine connector Open startand test function for industrial use stop button connection Limit switch and security contact connection Signal or traffic light card connector Garage light contact 24Vac outlet Electro lock connection INDUSTRIAL box with general circuit breaker switch Auto test outlet TRI ADVANCE Fast doors Semi automatic and RADIOBAND RCS automatic operations 433 or RADIOBAND RU or 868 MHz radio card with negative connector Open startand polarisation auto stop button connection test function Limit switch security contact and safety edge connection Hall sensor connection Signal or trafficlightcard garage light connector Connector for magnetic sensor card 24Vac outlet Electro break outlet INDUSTRIAL box with general circuit breaker switch Auto test outlet C Prox Quantek Systems www quantek co uk
13. door with control panel and RADIOBAND R rado 24 4 9 Installation on sliding door with control panel and RADIOBAND RC RCS card CONMCCIO la e UU TU UT 25 4 10 Installation on guillotine door with control panel and RADIOBAND RU 25 5 JCM CONTROL PANEL DIAGRAM FOR CONNECTION TO THE RADIOBAND SS C o 26 C Prox Quantek Systems www quantek co uk 1 INTRODUCTION 1 1 System description The Radioband system is designed for installation with a safety edge in garage door installations This system allows for wireless safety edge control panel connection To install this system you must follow the advice included in this manual and take therequirements of the applicable normative into account 1 2 Normative requirements Thedirectives applicable to this system are 98 37 EC Machines Directive 73 23 EEC Low Voltage Directive 2004 108 EC Electromagnetic Compatibility Directive R amp TTE 1999 5 EC Radio and telecommunication terminal equipment Directive Below are some of the requirements of the applicable harmonised standards In accordance with the European low voltage directive you are informed of the following requirements For permanently connected equipment an easily accessible connection device must be incorporated into the cabling This equipment must be installed in a vertical position and firmly fixed to the structure of the building This equipment may o
14. e prohibited except for changing the code setting or replacing the battery THERE ARE NO OTHER USER SERVICEABLE PARTS Any other changes made not expressly approved by JCM Technologies S A could void the user s authority to operate the equipment CE DECLARATION OF CONFORMITY See website www motion line com CE FE TUV C Prox Quantek Systems www quantek co uk 2 THESYSTEM 2 1 RADIOBAND TA RADIOBAND TBX RADIOBAND TA oafety edge connection Programmingbutton RADIOBAND TBX oo RADIOBAND TA RADIOBAND TBX Operating frequency 868 90MHz 868 90M82 Op consumption 85 x 53 x 36mm 160 x 53 x 20mm Range guaranteed Battery life estimated Minimum time between two RADIOBAND TA or RADIOBAND TBX activations for complying with the R amp TTE Directive C Prox Quantek Systems www quantek co uk INSTALLATION AND CONNECTIONS Fix the back of the box to the door Install the transmitter following the technical manual and avoid placing metallic surfaces between the receiver and the transmitter Pass the cables through the bottom of the transmitter Connect a resistive 8K2 safety band directly to terminal B1 and ensure that the safety edge keeps totally waterproof Fix the front of the transmitter to the back with the screws suppliedforthe purpose N B If a non resistive element with a contact normally closed needs to be connected the jumper JP4 must be bridged This application does not comply with
15. he door C Prox Quantek Systems www quantek co uk 2 3 RADIOBAND RC RCS zl Conector para cuadro de maniobra Connecteur pour armoire de commande Connector for control panel Anschluss f r Steuerung an Leds de indicaci n activaci n elemento de seguridad Leds indiquant l activation de l l ment de s curit Safety element activation indicator lights Anzetgeleds for Aktivierung des Sicherhertselementes imi Pulsador de programaci n Bouton de pragrammation Programming button Pragrammischalter Led y pulsador de verificaci n Led et poussoir de verification Check led and check button Check Led und Check Taster 868 90MHz Memory 6 RADIOBAND TA and or RADIOBAND TBX Powersupply pluggable A Powersupply range Consumption idle op C Prox Quantek Systems www quantek co uk INSTALLATION AND CONNECTIONS Connection to a control panel using a connector for safety devices LIGHT INDICATORS U RC RCS Indicates the status of the relay output programmed If R1 is not connected on Relay 2 LED Normallyoff On Indicates the channel to be Indicates the status of the relay output programmed If R2 is not connected on OPERATION The receiver checks that all the programmed bands are working properly If a band is activated or if there is an error in its operation the receiver activates the output relay MANUAL PROGRAMMING RADIOBAND RC RCS makes it possible to store 6 RADIOBAND TAs and or RA
16. installed bands continuous flashes ranging from 1 to 5 indicate the signal coverage for this band at the time it was pressed Number of check LED Coverage Result of check flashes Band failure Very good TOTAL RESET In programming mode Keep the programming PROG button pressed down and make a bridge with the MR reset jumper for 3s The receiver will emit 10 warning sound signals and then more at a faster frequency indicating that the operation has been carried out The receiver will stay in programming mode If 10 seconds elapse without programming or if you press the programming button quickly the receiver will go out of programming mode emitting two 1s sound Signals C Prox Quantek Systems www quantek co uk INSTALLATION ADVICE An AED 868 or FLAT 868 antenna extension to 868 MHz should be installed for greater range Install the external antenna and its cable at a place where they are protected against damage and vibration and where no obstacles are expected between all RADIOBAND antennas Where n antenna extension is not installed place the receiver card antenna in vertical position 868MHz AED 868 or FLAT 868 antenna extension with RG 58 coaxial cable Once the system has been installed check it works correctly by enabling the safety edge on the ends of the door C Prox Quantek Systems www quantek co uk 3 AUTO TEST FUNCTION 3 1 AUTO TEST DESCRIPTION Before starting operat
17. ions the control panel must check that the entire security system is working correctly The control panel shall not start Auto test during a pressed safety edge output To make this check the panel must act on the auto test signal e AUTO TEST timing correct T sutot st Tend i I Autotest d RADIOBAND TA status Auto test carried out CS indicates the correct autotest of all bands Autotest OK The operation can now be carried out e AUTO TEST timing error I Autotest I I I RADIOBAND TA status de Auto test carried out I CS indicates the correct 7 i autotest of all Autotest Error bands THE OPERATION CANNOT BE STARED AS THE AUTO TEST HAS NOT BEEN SUCCESSFULLY COMPLETED While the auto test is being run to learn of the status of the RADIOBAND TA or RADIOBAND TBX the RADIOBAND RU questions the status of the different Safety edges inputs This process ensures the correct working order of the following parts e Safety edge input e RADIOBAND TA or RADIOBAND TBX 1 or several e RFChannel if there is any interference C Prox Quantek Systems www quantek co uk e RADIOBAND RU control and RF Switching off the output relay means that the control status and the correct working order of the RADIOBAND RU output relay has been checked Description Tauto test Tend 3 2 RADIOBAND RCS CONNECTIONS 5V O 1 Not connected 2 RB S1 Outlet 1 Radioband activation 3 Mass 4 RB
18. nly be handled by a specialized installer by maintenance staff or by a properly instructed operator The instructions for use of this equipment must always remain in the possession of the user Terminals with a maximum section of 3 8mm2 must be used to connect the cables The frequency of the Radioband system does not interfere in any way with the 868 MHz remote control systems However a signal centred at 868 9MHz may cause a delay on the reaction of the system Always connect the door structure and metal parts to an earthing connection Do not share the power and signal supply C Prox Quantek Systems www quantek co uk The Radioband system is in line with the Machines Directive under EN 954 1 Category 2 JCM TECHNOLOGIES S A declares herewith that the product RADIOBAND TA RADIOBAND TBX RADIOBAND RU RADIOBAND RC RCS complies with the requirements of the 1999 5 CEE R amp TTE Directive 89 336 EEC Directive on electromagnetic compatibility and 73 23 EEC on low voltage and its subsequent amendment 93 68 EEC insofar as the product is used correctly This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation To comply with FCC rules adjustment or modifications of this receiver and or transmitter ar
19. o have range problems ak between the transmitter and the receiver the antenna must stand vertically from the hole in the gland Do not fit the equipment at ground level Do not place metal surfaces between the transmitter and the receiver The transmitter and receiver antenna must be parallel to each other for DM optimum signal reception Oncethe system has been installed check it works correctly by enabling the safety edge on the ends of the door C Prox Quantek Systems www quantek co uk 2 2 RADIOBAND RU 6 5 4 1 3 2 12 24V R1 ac dc 4 1 x R FI P EI Puente Selector Ri D Pulsador de programaci n Ponte S lecteur J3 Poussoir de Programmation Selector Bridge R1 Programming button Steckbrucke R1 Pragrammier schalter 7 ra El Puente Selector RZ ii Puente de Reset Total MR Pontet S lecteur J4 Fontet MR pour effacement des RADIOBAND Transmetteurs Selector Bridge RZ Total Reset Bridge MR Steckbrucke RZ Reset Uberbruckung Total MR 3 A 5 Gell Leds de indicaci n activaci n reles Gell Led y pulsador de verificacion Leds de signalisation activation des relais Led et poussoir de verification Relay activated indicator lights Check led and check button and low battery in Radioband T Check Led und Check Taster Anzeigeleds fur die Aktivierung des Relais und Batterie fast leer in Radioband T Frequency 868 90MHz Memory 6 RADIOBAND TA and or RADIOBAND TBX 3 on relay 1 3 on relay
20. p button connection Limit switch and security contact connection Signal ortraffic light card connector Garage light contact 24Vac outlet Electro lock connection Auto test outlet Dead man operations Built in 868 MHz receiver Open close start and stop button connection Limit switch and security contact connection Signal or traffic light card connector Garage light contact 24Vac outlet Semi automatic and automatic operations 433 or 868 MHz radio card connector Start and stop button connection Limit Switch safety edge and security contact connection Signal or traffic light card connector Garage light contact 24Vac outlet Auto test outlet Winding and RADIOBAND RU sectional for industrial use RADIOBAND RU Sectional swing and sliding for community use C Prox Quantek Systems www quantek co uk TRIBASIC S I Same as Sameas TRIBASIC RADIOBAND RU TRIBASIC withoutON OFF switch Auto test outlet TRIBASIC IND Same as Same as TRIBASIC butin RADIOBAND RU TRIBASIC INDUSTRIAL box Auto test outlet INDUSTRIAL Swing for Dead man operations RADIOBAND RU MAN industrialuse 433 or 868 MHz radio card connector Open start and stop button connection Limit switch connection Signal ortraffic light card connector Garage light contact 24Vac outlet Electro lock connection INDUSTRIAL box with general circuit breaker switch INDUSTRIAL EU Swing Semi automatic and RADIOBAND RU sectional
21. radio card connector Start pedestrian stop open and close button connection Limit switch safety edge and security contact connection Traffic light connector Garage lightand signal contact 24Vac outlet Electro lock connection Same as STANDARD 1T EU 1T EU for 2 motors C Prox Quantek Systems www quantek co uk automatic operations automatic operations Same as STANDARD RADIOBAND RC or RADIOBAND RU with negative polarisation auto test function RADIOBAND RU RADIOBAND RU D C PANELS JCM Control panels CONTINUE EU NUA D C PANELS Applications Description Compatibility with Radioband system Sectional swing folding and sliding for residential and community use Semi automatic and RADIOBAND RU automaticoperations by limit switch or with Hall sensor Time control Electronic motor power limitation without the need for additional devices 433 or 868 MHz radio card connector Start and stop button connection Limit switch safety edge and security contact connection Garage light contact 24Vac outlet THREE PHASE PANELS JCM Control Applications Description Compatibility with panels Radioband system UNIVERSAL EU TRIBASIC MOTION TRIBASIC RADIOBAND RU with positive polarisation auto test function Sectional swing Semi automatic and and guillotine for automatic operations 433 community use or 868 MHz radio card connector Open start and sto
22. reception Do not fit the equipment at ground level Do not place metal surfaces between the transmitter and the receiver The transmitter and receiver antenna must be parallel to each other for optimum signal reception C Prox Quantek Systems www quantek co uk a Connection to safety edge inlet RADIOBAND R CONTROL PANEL O 12 24V ac dc a Vac 24Vac d OP SEC OL OP STOP CLOSE l OP ATESTI __ COM ATEST SEC EDGE CONNECTION TO SAFETY EDGE CONTACT b Connection to security contact inlet RADIOBAND R CONTROL PANEL Qe QR o pelo qoo ale ee PE e b C C c dc T 24Vac NE dL OP SEC CL OP CL OP S ATESTI K COM ATEST SEC EDGE CONNECTION TO SECURITY CONTACT C Prox Quantek Systems www quantek co uk C Auto test connection with negative polarisation RADIOBAND R ATEST PO CONTROL PANEL J3 445 CSI BS1 CS2 BS2 B1B2 12 24V ac dc AUTOTEST CONNECTION NEGATIVE POLARIZATION d Auto test connection with positive polarisation RADIOBAND R ATEST PO CONTROL PANEL CS1 BSI CS2 BS2 1e agio aie alo aec O Vac EE OP SEC CL OP E CL E 3 COM AJTEST SEC EDGE AUTOTEST CONNECTION POSITIVE POLARIZATION Oncethe system has been installed check it works correctly by enabling the safety edge on the ends of t
23. safety standard EN 12453 for the use of motorised garage doors since the connection of the resistive element to the RADIOBAND TA and RADIOBAND TBX is not checked OPERATION The receiver checks that all the programmed bands are working properly If a band is activated or if there is an error in its operation the receiver activates the output relay PROGRAMMING RADIOBAND TA RADIOBAND TBX If the receiver is in programming see MANUAL PROGRAMMING on page 10 or 16 pressthe transmitter button to programme it into the receiver TRANSMITTER BATTERY LOW INDICATOR RADIOBAND TA RADIOBAND TBX If the battery of a transmitter programmed into the receiver becomes low it will give out 4 short signals every 20 seconds If there is more than one transmitter programmed the safety band must be activated to check whether the receiver then makes these 4 short signals If this is the case the transmitter connected to the activated safety band will be the one with the low battery Change it CHANGING THE BATTERY Remove the box cover The batteries are positioned on the back of the cover Replace the two used batteries with new ones taking into account the polarity indicated by the connector Check that the new batteries support the same temperature range as those they are replacing C Prox Quantek Systems www quantek co uk INSTALLATION ADVICE Install the equipment so that m the cable outlet is at the bottom Y In installations likely t