1. Installation and User Manual Tole A oo VKBD3i User and Installation Manual Electromagnetic Compatibility EMC This is a Class A product in a domestic environment it may cause radio interference if this is the case the user may be required to take remedial measures Manufacturer s Declaration of Conformance A Declaration of Conformity in accordance with the following EU standards has been made and Is kept on file at Norbain SD Ltd Norbain House Eskdale Road Wokingham RG41 5TS The manufacturer declares that the product supplied with this document is compliant the provisions of the EMC Directive 89 336 EEC the Low Voltage Directive LVD 73 23 the CE Marking Directive 93 68 EEC the RoHS directive 2002 95 EC and all associated amendments Specification subject to change without notice This document is intended to provide accurate information however the information contained herein is subject to change without notice Vista in keeping pace with technological advances is a company of product innovation Therefore itis difficult to ensure that all information provided is entirely accurate and up to date Vista accepts no responsibility for any inaccuracies or omissions and specifically disclaims any liabilities loss or risk personal or otherwise which Is incurred as a consequence directly or indirectly of the use and or application of any of the contents of this document 39535 3 l V1 13 VKBD3i User and Ins
2. Vista Blade DVRs complete range Vista Matrices VDC and VMS ranges Vista Eclipse Domes Vista VEC43 Camera Range Vista VZM camera range While the keyboard may control other non Vista BaxNet devices these are not supported by Vista and we do not expect full compatibility Powering the VKBD3i Keyboard For the Navigator DVR Columbus Triplex DVR VMS Matrix and VDC 1604 Matrix If the keyboard is within 2m of either a Columbus Triplex DVR or VDC 1604 Matrix then the keyboard can be powered via the RJ 45 lead If the unit is more than 2m from the keyboard then an external power adaptor e g the VPSU500 12 will be required When external power is used or multiple devices are connected together it is important that pins 1 2 7 amp 8 are not connected on the interconnecting RS485 cables For Vista Blade DVR For the Blade DVR a Separate power supply will be required e g the VPSU500 12 this simply plugs into the 2 1mm jack socket on the rear of the keyboard 39535 3 6 V1 13 VKBD3i User and Installation Manual Keyboard Operation Keyboard buttons symbols The keyboard contains 31 tactile buttons any buttons that have a blue symbol on the top left corner have a dual function this second function is access by using the blue shift key Please note that not all key presses are available on all Control units X deari airh T aa e m P hs i N ae 39535 3 Shift Key Used to select fu
3. be set from within the Dome Menu DD Call a Learn Tour Pattern 1 U An alternate tour type available on some domes to help the surveillance of your site is the Learn Tour or Pattern Unlike the Preset Tour the Learn Tour does not jump from Preset to Preset but is a copy of a control session that is remembered inside the Dome To call a pre programmed Learn Tour Use the numeric keys to enter the Learn Tour number followed by the Learn Tour key Preset Tour No Learn Tour 39535 3 10 V1 13 VKBD3i User and Installation Manual Fn bp ox Set a Learn Tour Pattern Thy aly fu To program a Learn Tour if permission is enabled Pan Tiltand Zoom the camera to the desired start of the tour then Use the numeric keys to enter the Learn Tour number followed by Shift Function and Learn keys Learn No Shift Fn Learn Now Press enter to start the countdown time available for the tour when the countdown starts perform the control session that you wish to record When you have finished press Enter Ent D 180 degree Flip If your dome supports it activating this feature will cause the dome to rotate by 180 degrees so itis looking in the opposite direction To select 180 degree flip Press Shift followed by the 180 Degree Flip key Shift 180 Degree Flip 10 Day Night 1 To Toggle between the Day amp Night modes colour monoc
4. press this key to select Reverse Play To toggle wipers on off while in Telemetry Mode first press the Shift key Stop amp Lamps Key Press to Stop playback To toggle lamps on off while in Telemetry Mode first press the Shift key Play amp Record Key Press to Play Forwards To toggle recording on off first press the Shift key Enter Increment amp Help Key If you press the Camera key or Preset key in telemetry mode without selecting a number pressing this key will step up to the next available camera or preset In menus this is the Enter Key To bring up a Menu Help Screen if available first press the Shift key Escape Decrement amp Electronic Zoom Key If you press the Camera Key or Preset key in telemetry mode without selecting a number pressing this key will step down to the next camera or preset In menu mode this is the Escape On a Triplex DVR To toggle Electronic Zoom first press the Shift key Iris Open amp Auto Iris Key To open the iris press this key To select Auto Iris mode press the Shift key first alternately Pan the unit Iris Close amp Day Night Key To Close the Iris press this key To Toggle between the Day amp Night modes colour monochrome on Domes that support this feature Focus Far amp Auto Focus Key To focus on distant objects press this key To enter Auto Focus mode press the Shift key first alternately Pan the unit Focus Near amp Telemetry key To focus
5. second DVR subsequent units are connected together by repeating this process Next DVR OOOO VPSU500 12 power supply not included Note Each Columbus DVR needs to be addressed separately See Communications section of the Columbus Menu structure Connecting to multiple Navigator DVRs or VDC Matrices As the Navigator DVR and VDC matrix have a single RJ 45 connector it is necessary to use a breakout box to connect multiple units together It will be necessary to power the keyboard remotely using a VPSU500 12 power supply not included The data connection to the keyboard is then made via the breakout box supplied Connect the Supplied RJ 45 cable to either of the Sockets on the keyboard and the other end to the breakout box Then connect the Network Plus Black to pin 3 of an RJ 45 plug and Network Minus Yellow to pin 6 of the RJ 45 plug Connect this RJ 45 plug into the socket marked as Keyboard For the second and subsequent units further breakout boxes are required make up a second single ended RJ 45 lead an connect this to pins 3 and 6 then plug into the next breakout box and connect the Network Plus Black to pin 3 of an RJ 45 plug and Network Minus Yellow to pin 6 of the RJ 45 plug Connect this RJ 45 plug into the socket of the second unit marked as Baxnet or Keyboard te a oae ete ae ral BI QOQOO OOOO f YL VPSU500 12 power supply not included 39535 3 18 V1 13 VKBD3i User and Insta
6. 1st uly 2006 new electrical and electronic equipment put onto the market in the EU must not contain any of the restricted Substances referred to in Article 4 1 of the RoHS Directive at concentrations in excess of those permitted under the Directive unless covered by an Exemption This unit is in compliance with the requirements of the RoHS Directive 39535 3 4 V1 13 VKBD3i User and Installation Manual Unpacking Keep your packaging for use should your keyboard be stored or need to be returned Included in the box will be e VKBD3i Keyboard e RJ 45 lead patch lead e Rubber feet for keyboard e Rj 45 break out box e These instructions Check the product number on the serial number label If you have the incorrect item or it is damaged then inform your agent and the Carriers immediately If the equipment is incorrect or damaged do not attempt to use it 39535 3 5 V1 13 VKBD3i User and Installation Manual Equipment range controlled by VKBD3i The VKBD3i is a CCTV control keyboard that utilises two proprietary EIA RS485 control protocols BaxNet protocol for control of the Vista DVRs and Matrices and Vista VPD protocol for the direct control of Vista cameras and Domes A single keyboard can operate multiple units device dependant or up to 4 keyboards can be used to control a single device The VKBD3i is compatible with the following devices Vista PowerDome 1 and 2 Vista PowerDome Lite 4 and 5 Vista Columbus DVRs complete range
7. 2s n c n c 2 3 4 5 6 7 8 Dip Switch bank The address is setup in a binary addition mode Value of each switch as follows 1 1 2 2 3 4 4 8 5 16 6 32 Addresses can be set between 1 and 32 E g address 17 would need switches 1 and 5 16 1 to be switched on Appendix A Pin Assignment Breakout Box Pins RJ 45 Socket Pins Pin Assignment 12345678 1 9 12VDC ve 2 9 12VDC we 4 VPD RS485 ve 5 VPD RS485 ve 6 BaxNet ve 8 AND 39535 3 20 V1 13 VKBD3i User and Installation Manual Appendix B J oystick Calibration The joystick on your keyboard has been factory calibrated to ensure even control of the Pan Tilt and Zoom features on any controllable cameras If you need to re calibrate the joystick please carry out the following procedure Down power the keyboard Press and Hold the 0 key while you re power the keyboard Wait till you here a beep then release the O key All the LEDs will be flashing Press 5 Push the joystick fully LEFT and hold while you press 4 Push the joystick fully RIGHT and hold while you press 6 Push the joystick fully UP and hold while you press 2 Push the joystick fully Down and hold while you press 8 Twist the joystick fully anti clockwise and hold while you press Camera Twist the joystick fully clockwise and hold while you press Monitor Press 0 to finish calibration 39535 3 21 V1 13 VKBD3i User and
8. Commands Telemetry Enable Disable T 4 gt For the Triplex DVR you need to enable Telemetry mode to be able to control Movable Cameras this is not required on the other control equipment To toggle telemetry control On Off Press Shift followed by the Telemetry key Shift T To make telemetry control easier you can also use these alternative methods to Enable and Disable telemetry mode on the Triplex DVR Enable Tap the joystick and wait for 1 second Disable Press a non telemetry key e g alarm Pan Tilt amp Zoom the Dome J oystick Use the joystick to move the dome Left Right Up and Down on most domes the speed of travel will be proportional to both how far you move the joystick in a given direction and to the level of Zoom magnification Slowing down as you Zoom IN The grip on the joystick can be rotated to zoom the lens clockwise for Zoom In and counter clockwise to Zoom out On many Domes when you reach the extreme Down position the camera will automatically flip by 180 degrees and then pan UP Al iD Iris Control amp amp Most Dome cameras have Auto Iris control to maintain the correct picture exposure If you wish to override this Auto Iris control the Iris on most Dome cameras can be opened and shut by using the Iris Open and Iris Close keys To re enable Auto Iris just Pan the camera again however on some Domes you can re enable Auto Iris by pressing Shift followed by Iris Open Shift Iris O
9. Installation Manual This page is intentionally left blank 39535 3 22 V1 13 VKBD3i User and Installation Manual Subject to change without notice 39535 3 ee NORBAIN SD LTD Norbain House Eskdale Road Winnersh Triangle Wokingham Berks RG41 5TS V1 13
10. afety and operating instructions should be read before the unit is operated A To prevent fire or shock hazard do not expose this equipment to rain or moisture The lightning flash with arrowhead symbol within an equilateral triangle is intended to alert the user of this equipment that there are dangerous voltages within the enclosure which may be of sufficient magnitude to constitute a risk of electric shock WARNING This is a class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures Lightning Strike The unit has some inbuilt protection for lightning strike however it is recommended that isolation transformers be fitted to the system in areas where lightning is a common occurs CE MARK ce If this product is marked with the CE symbol it indicates compliance with all applicable directives Directive 89 336 EEC WEEE Status All our products that are covered by the WEEE directive are marked with the Wheeled Bin logo as required by the Directive Where we have a producer responsibility under the WEEE Directive we plan to join a national WEEE Producer Compliance Scheme in the UK and in Malta when their WEEE legislation is finalised Anybody responsible for importing this product from the UK into another EU member State will have to ensure that they comply with the WEEE laws applicable in that country ROHS STATUS F From
11. efore you begin Important S afeguards Unpacking Equipment Controlled by the VKBD3i Powering the VKBD3i USER INSTRUCTIONS Keyboard Operation Table of keys and there function Unit Control Commands Telemetry Commands DVR Commands Table of key presses for DVR functions INSTALATION INSTRUCTIONS Single Keyboard to Single local unit within 2m Columbus Triplex Navigator VDC 1604 Matrix VMS Matrix Blade DVR Single Keyboard to single remote unit more than 2m Columbus Triplex Navigator VDC 1604 Matrix Direct Control of PowerDome or remote set up cameras Connecting to a PowerDome Interface Board Single Keyboard to Multiple Units Multiple Columbus Triplex Multiple Navigator DVRs or VDC 1604 Matrices Multiple Blades Keyboard Addressing Appendix A Pin assignments Appendix B oystick Calibration Page Or Or OT MRI Fe V1 13 VKBD3i User and Installation Manual Important Safequards READ INSTRUCTIONS All the safety and operating instructions should be read before the unit is operated Retain this document for future reference POWER SOURCES This unit should be operated only from the type of power source indicated on the manufacturer s label SERVICING Do not attempt to service this unit yourself as opening or removing covers may expose you to dangerous voltage or other hazards Refer all servicing to qualified service personnel VENTILATION Ensure unit is properly ventilated to protect from overheating All the s
12. elect the function and Esc Left to exit the menu 39535 3 8 V1 13 VKBD3i User and Installation Manual Fn Function Triplex 1 The Vista Triplex DVR can be programmed to carry out complicated actions that are assigned to Functions these are normally used during alarms but they cam be called directly from the keyboard Use the numeric Keys to enter the number of the required Function then press the Function key Fn No Fn There are special key presses used while writing a Triplex Function see the Triplex manual these should be entered from the keys on the front of the Triplex The Function key is also used as a modifier to allow you to call several features on the equipment being controlled this is detailed in the description on the feature Aud Audio Blade 1 at To select the required audio channel for live monitoring or playback Use the numeric keys to enter the number of required audio channel followed by the Shift key and then the Audio key Audio no Shift Audio P Freeze Live Picture To Freeze the live picture on the digital monitor output of the Blade and Triplex Press Pause Pause Help The help key is reserved for future use To view the contextual help pages on the Navigator DVR select the on screen Help tab A Print sli The Print key is reserved for future use 39535 3 Q V1 13 VKBD3i User and Installation Manual Telemetry
13. equirements please see below Socket locations For the Columbus DVR Range the Keyboard is plugged into either of the RJ 45 sockets marked as RS485 1 or 2 located within a group of 4 sockets on the right hand side of the rear of the unit ETHER AS 485 1 10 100 r W For the Navigator DVR Range the keyboard is plugged into the RJ 45 socket marked as BAXNET located on the top left of the rear of the unit o W BAXNET For the VDC Matrix range the keyboard is plugged into the RJ 45 socket marked as KEYBOARD located on the lower right hand side of the unit 39535 3 14 V1 13 VKBD3i User and Installation Manual Single keyboard operation for VMS Matrix It is important NOT to connect the VPD data pins 5 amp b6 into the VMS matrix This is achieved by connecting the keyboard to the breakout box with the RJ 45 lead supplied Then using another RJ 45 lead with only a single end connect pin 3 Green White to the Black BK connector on the breakout box and pin 6 Solid Green to the Yellow YL connector of the breakout box See below Total cable can be up to 1200m long W CHOO VPSU500 12 power supply not included Connecting VKBD3i directly to a Vista Blade DVR When connecting to a Vista Blade DVR the keyboard will need to be powered using the power supply included in the packaging this is plugged into the keyboard using the 2 1mm socket adjacent to the 2 RJ 45 sockets The Blade DVR differs from o
14. h as much data of both older and newer of the unit s current Play Pointer see Play Forwards for a description of the Play pointer To enter the DVR s Quick Archive Menu Press the Quick Archive key Archive Record Modern DVRS are permanently in Record Mode however on the Triplex DVR itis possible to configure the DVR to allow the user to turn Recording off On a Triplex DVR in this mode to turn off recording Press Shift followed by Record use the joystick to Select YES then press Enter Shift Rec Select Yes Ent Table of DVR Commands Rev Left ma Down 39535 3 13 V1 13 VKBD3i User and Installation Manual Installation The VKBD31 is a very versatile keyboard and is capable of being used in a variety of configurations from controlling a single camera through to controlling multiple DVRs or Matrices The following section covers these various options Single keyboard to single unit When connecting a single VKBD3i Keyboard locally within 2m to any of the following units Vista Columbus Range Vista Navigator Range Vista VDC Matrix Simply connect the Supplied RJ 45 Cable into either of the two RJ 45 sockets on the rear of the Keyboard and into a corresponding RJ 45 Socket on the DVR or Matrix See diagrams below The DVR or Matrix will power the keyboard With the Vista Blade DVR a separate power supply will always be required we recommend the VPSU12 500 The Vista VMS matrix has Special wiring r
15. hrome on Domes that support this feature Press Shift followed by the Day Night key Shift Day Night Fah Camera Menu ath X Many of the features of a modern dome are accessed from within its menu structure Each dome has its own method of entering its menus and so the key press used depends in the dome being control and the protocol being used to control it Where possible the control equipment will translate the following key press to that required by the dome however if this does not work you will need to consult the Dome manual to find the correct key press Press Shift followed by the Dome Menu key Shift Dome Menu Auxiliary Commands These commands are used to switch the auxiliary functions on standard Pan Tilt cameras but they can be used on some modern domes to activate various features depending on the model please consult the dome manual Camera Power Toggle the camera power On Off Auto Pan Automatically scan between two points normally set at the Pan Tilt Head Wipers Toggle the Wipers On Off Washers Momentary activate the washer Lamps Toggle the Lamps On Off 39535 3 11 V1 13 VKBD3i User and Installation Manual DVR Control Commands To put a DVR into Play mode you normally use the Play Forward key you then have access to the other play features Exact control depends on the DVR itself and you should read the DVR manual in conjunction with this manual Fn DVR Mode ath y As we
16. least 2 seconds Press and Hold Play Forwards Fast Forward J oystick Up To play back in Fast Forward Push the J oystick Up Up a Reverse Play To Reverse Play from play Press the Reverse Play key Reverse Play Fast Reverse Rewind J oystick Down To playback in Fast Reverse Push the J oystick Down Down Pause To pause the playback of a recording Press Pause Pause 39535 3 12 V1 13 VKBD3i User and Installation Manual Step Forwards DVR dependant To step forward from Paused playback use the following DVR dependant key presses Triplex Right Navigator amp Blade Pause Zoom In Step Back DVR dependant To step Backwards from Paused playback use the following DVR dependant key presses Triplex Left Navigator amp Blade Pause Zoom Out Search amp Archive S A DVR s Search menu gives the user several ways to search and select the required recorded data for playback or archive Each DVR has its individual method of Searching and Archiving recordings accessed through its Search Menu please consult the DVRs manual to understand how to Search and Archive To enter the DVR s Search and Archive Menu Press the Search key Search eo Quick Archive Each DVR has Its individual method of performing a Quick Archive of recordings accessed though it s Quick Archive Menu please consult the DVRs manual to understand how to Search and Archive Quick Archive fills the archive medium wit
17. ll as using the following dedicated DVR keys you can normally also use the Pan Tilt and Zoom joystick to control your DVR this is directly supported by the Triplex DVR while on the Navigator and Blade DVRs you need you must enter DVR mode with the following key press Press Shift followed by Function both LEDs should remain lit Shift Fn A table of the key presses for each DVR is shown at the end of this section Play Forwards To Play Forwards from the play pointer Press the Play key Play Forwards The Play pointer is the part of the recording that playback will start from this is different for each DVR Blade The point at which the last play back session was stopped see Replay Triplex The point at which the last play back session was stopped Navigator A set time ago that is set inside the DVR default 2mins See GOTO e Replay Blade Press and Hold On the Blade DVR there is a special Play Forward mode called Replay Using this feature the DVR will play forwards from a set time ago that is set inside the DVR default 5 seconds to activate Replay Press amp Hold Play forwards for at least 2 seconds Press and Hold Play Forwards Goto Navigator Press and Hold On the Navigator there is a special forward play command called Goto This feature the will invoke a menu where you can quickly enter a time and date from which to start forward play to activate Goto Press amp Hold Play forwards for at
18. llation Manual Connecting to multiple Blades It will be necessary to power the keyboard remotely using a VPSU500 12 power supply not included The data connections to the keyboard are then made via the breakout box supplied Connect the Supplied RJ 45 cable to either of the Sockets on the keyboard and the other end to the breakout box Then connect the network plus Black to the RS485 1 TX on the Blade and network minus Yellow to the RS 485 1 TX on the Blade For the second and subsequent units further breakout boxes are required make up a single ended RJ 45 lead with only pins 3 and 6 connected then plug into the next break out box As with the first Blade connect the network plus Black to the RS 485 1 TX on the Blade and network minus Yellow to the RS485 1 TX on the Blade Then continue this chain for all Blades VPSU500 12 power supply not included Each Blade needs to have its address and the RS 485 1 port configured See the Serial Comms section within the System menu 39535 3 19 V1 13 VKBD3i User and Installation Manual Addressing the keyboard The RS485 address of the keyboard is set to 9 out of the box To change this address it is necessary to adjust a bank of dipswitches within the keyboard 4 screws secure the rear of the keyboard case remove these screws to reveal the PCB and there are a single bank of dip switches on the board Rear view of keyboard with back off 1s 2s 4s 8s 16s 3
19. m the camera is connected to the screw terminals on the breakout box data ve connected to pin 4 the green GR terminal and data ve connected to pin 5 the red RD terminal See soo Zo Telemetry m a GQ OOO VYPSU500 12 power supply not included Connecting to a PowerDome Interface Board Pin Numbering or Marking Data Line VKBD3iR 45 BreakoutBox Dome 1 0 Board RS485 ve 4 4 RS422A RS485 ve 5 5 RS422B e fcontrol is not achieved try swapping over the data cables as these are polarity sensitive e If control is not achieved or is intermittent check the data termination on the camera or dome e If there are to be multiple domes or cameras controlled directly then it would be advisable to use a data distribution amplifier such as the Vista VSD16 39535 3 17 V1 13 VKBD3i User and Installation Manual Single Keyboard controlling multiple DVRs or Matrices A single Vista VKBD3i keyboard can control up to 31 DVRs The connection method will vary depending on the units to be controlled Each connection scenario is dealt with separately below Connecting to multiple Columbus DVRs Connect the first DVR to the keyboard as normal Then using another RJ 45 lead with only a single end connect pin 3 Green White to the Black BK connector on the breakout box and pin 6 Solid Green to the Yellow YL connector of the breakout box see below Then insert the single RJ 45 plug into the RS 485 1 socket on the
20. n using an approved RS485 cable Triplex Connections Total cable length can be up to 1200m long RJ45 sext FQ FF VPSU500 12 power supply not included Navigator Connections Total cable can be up to 1200m long VPSU500 12 power supply not included VDC 1604 Connections Total cable can be up to 1200m long VPSU500 12 power supply not included 39535 3 16 V1 13 VKBD3i User and Installation Manual Direct control of PTZ domes or static remote set up cameras The VKBD3i keyboard can be used to send RS 485 Vista PowerDome control protocol directly to a PTZ dome or static remote set up camera The camera ranges capable of being controlled in this way are Vista PowerDome 1 and 2 Vista PowerDome Lite 4 and 5 Vista Eclipse Domes Vista VEC 43 Camera Range Vista VZM camera range If the Keyboard is stand alone or further than 2 metres from a DVR or Matrix then a separate power supply needs to be plugged into the 2 1mm jack socket on the rear of the keyboard adjacent to the two RJ 45 sockets e M Telemetry 7 8866 Telemetry ms QVOOY VPSUSOO 12 power supply not included The Vista PowerDome Protocol is transmitted on pins 4 ve and 5 ve on both of the keyboards RJ 45 sockets this is the blue amp blue white pair of a standard RJ 45 patch lead Plug the RJ 45 Lead into either socket on the keyboard Then plug the other end into the RJ 45 socket of the break out box The data cable fro
21. nctions displayed in Blue on the keys Below shifted functions are shown in square brackets Dome Learn Tour amp 180 degree Flip Key Select the Learn Tour number followed by this key To make a 180 Degree rotational Flip while in Telemetry Mode first press the Shift key Multi screen amp Sequence Key For multi screen option repeat key presses till desired screen option is displayed For Sequence first press the Shift key Alarm Acknowledge amp Printer key To acknowledge Alarms press this key For the direct printer option first press the Shift key for future use Unit Select Function amp DVR Mode Key Select the unit number followed by this key To run a Macro Function press Shift then Fn Number then Fn key On the Blade amp Navigator DVRs if you press Shift amp Fn the P T Z keys will control the DVR s play back speed and direction DVR Search amp Camera Power Key To bring up the search menu press this key For the Camera Power Auxiliary while in Telemetry Mode first press he Shift key DVR Archive amp Auto Pan Key To bring up the Quick Archive menu press this key for future use archive is done via Search For Auto Pan while in elemetry Mode first press the Shift key Pause Freeze amp Washer Key To Pause play back or Freeze live pictures press this key To toggle Washers on off while in Telemetry Mode first press he Shift key Reverse Play amp Wiper Key While in play back mode
22. nt multi screen display modes to calla DVR multi Screen view to the monitor being controlled Press Shift followed by the Multi Screen key Shift Multi screen This will step through the available views once a view is selected this will be remembered by the DVR and be the first view to be selected in future Sequence aft 1 EE To call a pre programmed sequence to the monitor being viewed Use the numeric keys to enter the sequence number followed by the Shift key amp then Sequence key Shift Seq No Seq key If the unit only has one sequence enter 1 as the sequence number Alarm Acknowledge If your system is set to receive alarms they can either be set to automatically clear when the alarm finishes or to time out after a programmable time or to require a manual acknowledgement from the user To manually acknowledge an alarm or terminate a time out alarm Press the Alarm Key Alarm m Enter Unit Menus af e Password Access to the unit s menus will be required to initially set it up or to change its settings Press Shift followed by the Unit Menu key then use the numeric keys to enter the password followed by the Enter key Shift M Password Enter The device s default password can be found in the installation manual for each device Once inside the menu use the J oystick Up Down to navigate to a function and then depending on the unit being controlled use Right Enter to s
23. on near objects press this key To toggle Telemetry mode ON OFF first press the Shift key alternatively simply tap the joystick to switch Telemetry On 0 9 Data entry keys Used to enter the required numeric data before a feature key is pressed 1 V1 13 VKBD3i User and Installation Manual Unit Control Commands UnitSelect 1 To control a unit from the keyboard you must first select the unit number to be controlled Use the numeric keys to enter the Unit Address 1 32 followed by the Unit Select key Unit No Unit select key Aud Monitor Select 1 To call cameras sequences or multi screens to a monitor output you need to select the monitor to be controlled Use the numeric Keys to enter the monitor number followed by Monitor key Mon No Mon key For convenience you can step through the monitor being controlled by pressing Shift followed by the Increment and Decrement keys If monitors are designated A and B then A Mon 1 amp B Mon 2 IP Camera Select 1 To select the desired camera to the monitor being controlled Use the numeric keys to enter the camera number followed by the Camera key Cam No Cam For convenience you can step through the camera being viewed by pressing Shift followed by the Increment and Decrement keys On the Blade DVR you can connect IP cameras to select these press Shift Cam No Cam Multi screen Views an The DVRs can call several differe
24. pen T AF Focus Control gt amp 4 Most Dome cameras have Auto Focus control to maintain the correct picture focus If you wish to override this Auto focus control the Focus on most Dome cameras can be adjusted by using the Focus Near and Focus Far keys To re enable Auto Focus just Pan the Camera again however on some Domes you can re enable Auto Focus by pressing Shift followed by Focus Far Shift Focus Far ra Call a Preset Most Dome cameras can be setto have one or more Preset Views or Presets these normally include the Pan Tilt and Zoom positions To call a pre programmed P reset Use the numeric key to enter the Preset Number followed by the Preset key Preset No P reset 1 Te X Seta Preset j To program a Preset if permission is enabled Pan Tilt and Zoom the camera to the desired view then Use the numeric keys to enter the Preset number followed by Shift Function and finally Preset Preset No Shift Fn Preset Calla Preset Tour e To automate the surveillance of your site on most Domes if you have several Presets programmed you can combine these into Preset Tours or just Tours To call a pre programmed Preset Tour Use the numeric keys to enter the Tour number followed by the Preset Tour key Preset Tour No Preset Tour Set a Preset Tour Preset tours cannot be set directly from the keyboard They must
25. tallation Manual BEFORE YOU BEGIN Read these instructions before installing or operating this product Retain this document for future reference Note This installation should be made by a qualified service person and should conform to local codes This manual provides installation and operation information To use this document you must have the following minimum qualifications e A basic knowledge of CCTV systems and components e A basic knowledge of electrical wiring and low voltage electrical connections INTENDED USE Only use this product for the designed purpose refer to the product specification and user documentation CUSTOMER SUPPORT For assistance in installing operating maintaining and troubleshooting this product refer to this document and any other documentation provided If you still have questions please contact Norbain Technical support and Services during normal business hours Monday through Friday excluding holidays between 8a m and 7p m 44 0 118 944 0123 Norbain House Eskdale Road Winnersh Triangle WOKINGHAM Berks RG415TS www vista cctv com for our online library tsg norbain com for technical support Note You should be at the equipment and ready with details of both the installation and the problem before calling technical support 39535 3 2 V1 13 VKBD3i User and Installation Manual Contents 39535 3 Item STANDARDS amp Cautions Manufacturer s declaration of Conformance B
26. thers in the range in that it does not have an RJ 45 socket for the keyboards therefore connection is made using the RJ 45 breakout box that is supplied Connect the keyboard to the breakout box using the supplied RJ 45 lead Then connect the Black BK to the TX and Yellow YL to the TX of the RS 485 port on the Blade This could be either port 1 or 2 woe St ice Se Te ae Cae VPSU500 12 power supply not included Note The RS485 connectors on the Blade DVR need to be configured within the Blade manual See the Serial Comms section within the System menu 39535 3 15 V1 13 VKBD3i User and Installation Manual Single Remote Keyboard Connection More than 2m from unit When the keyboard is to be located more than 2m from the unit it is necessary to power it remotely using a separate power supply such as the VPSU500 12 The data connection to the keyboard is then made via the breakout box supplied These instructions apply to the following Triplex DVR Navigator DVR Blade DVR amp the VDC106 Matrix Connect the Supplied RJ 45 cable to either of the Sockets on the keyboard and the other end to the breakout box Then using another RJ 45 lead with only a single end connect pin 3 Green White to the Black BK connector on the breakout box and pin 6 solid Green to the Yellow YL connector of the breakout box see below The cable length between the keyboard and the unit to be controlled can be up to 1200 meters whe
Download Pdf Manuals
Related Search
Related Contents
GB-AEDTK-SI GB-AEDNK-SI apc801201jp Istruzioni d`uso Instruções de Utilização Manual de instrucciones Physioláser olympic cp Instrucciones de operación - Rj 浜松医療センター学術誌 Samsung C61 RCDST User Manual Vaterra Rock Racer Canon i860 Series Quick Start Manual IFU MWD 202 GB 4619-652 Copyright © All rights reserved.