Home

Emlink User Manual V1_0

image

Contents

1. to drive the in puts please ensure the OV connections are common ed up Page 6 Main Menu 1 Main Menu 2 Main Features 3 Description 4 Hardware Layout 5 Hardware Description 5 Inputs 6 Outputs 6 Power Supplies 7 Data Channel 8 Basic Emlink1 Functions 9 Status amp Signal LED s 10 Additional Features 11 Emlink1 Programming 11 General 12 Data Channel Pairing and Baud Rate 13 Data Channel Parity and Protocol 14 Inputs 1 amp 2 Tx Pairing Signal and Input Mode 15 Inputs 1 amp 2 Input to output pairing 15 Outputs 1 amp 2 Pairing 16 Outputs 1 amp 2 Operational Modes amp Timer Periods 17 Outputs 1 amp 2 Relay Testing 17 Tamper Third Channel Overview 18 Tamper Third Channel Pairing amp Local Tamper Switch 19 Tamper Third Channel Status Update Monitoring 20 Repeat Mode Pairing 20 RF Channel Selection 21 Restore Factory Settings 22 Specifications Page 1 Hardware Description RS232 RS485 Data Channel On certain models of the Emlink1 a data channel with either RS232 or RS485 is supported Serial baud rates from 2400 to 19200 are possible with none odd or even parity Supported protocols are Pelco D amp P Emlink and an open channel An easy way to identify between a RS232 or a RS485 version is to look at the last digit of the units serial number R RS232 Supported N Network RS485 Supported The electrical connections for both t
2. 1 to transmit its status at a given period even if there are no input changes If a receiving Emlink1 has its status update monitoring enabled and there is a loss of signal a tamper fault will be generated Status Update Period Static LED s i Flashing LED s Tamper Input 1 amp ED s All Signal LED s off Tamper Input 1 amp 2 LED s Tamper Input 1 amp 2 LED s Tamper Input 1 amp 2 LED s Pagel9 Emlink Programming Data Channel Set Parity In this mode briefly pressing the right switch changes the parity for the RS232 RS485 port The parity must match the other communicating equipment s parity to function correctly Listed below is the LED states for the different parity set tings Flashing LED s Static LED s Data Signal LED 5 Signal LED 1 Data Signal LED 5 Signal LED 2 Data Signal LED 5 Signal LED 3 Data Channel Protocol In this mode briefly pressing the right switch changes the selected protocol for the RS232 RS485 port Currently 3 protocols are available which are listed below 1 Emlink protocol This protocol is used for outputting all paired devices radio transmissions over either RS232 or RS485 port It is also possible to control a paired Emlink1 s outputs via this protocol Typical uses for this is protocol are expander modules Extra I O channels Reading of an Emlink1 s analogue input voltages status monitoring in software door acc
3. 5 rated enclosure the Emlink1 is designed for indoor and outdoor use Each Emlink1 has 2 input channels which can accept either an analogue input signal from 0 to 24V DC for remote monitoring or a digital signal set by 4 thresh olds Outputs 1 amp 2 are volt free relay contacts and can be configured to work in 3 modes momentary toggle and timed outputs with intervals from 1 second to 30 minutes An option to pair its own input to output allows the Emlink1 to work as a timer as well as transmitting its status to other paired devices The third output can be switched between a tamper relay and a 3rd channel In tamper mode the Emlink1 can monitor local and remote tamper switches lost status update signal from remote units or report a paired input from a remote unit When not used as a tamper circuit the third channel can function as a momentary volt free output Other features include a built in signal strength meter site survey mode for the engineer to check signal strengths when installing units and a RS232 RS485 serial interface for transmission of protocols Pelco P amp D Emlink and an open channel protcol Page 3 Status Signal LED s Each input output on the Emlink1 has a closely mounted status LED to indicate the channel is active For the signal strength a strip of 6 LED s is mounted in the centre at the top of the Emlink1 A brief description of the status signal LED s is listed below Signal LED s
4. The signal LED s have 2 meanings when the display raises from the bottom upwards this indicates a received signal strength depending on the receive level will depend on how many LED s will light For a transmission the LED s will pulse from the centre outwards Inputs Outputs 1 amp 2 The input output LED s for channels 1 amp 2 flash at half second intervals when a channel is active Channel 3 Tamper The status LED flashes at half second intervals providing the tamper fault is local if a remote tamper fault has been detected the status LED will pulse twice When using this output as a third channel the status LED will only flash at half second intervals when active Data Channel Data Models Only The status LED on the data channel emits a short pulse when sending or receiving data over the RS232 or RS485 port If the status LED stays on continuously for half a second or more there is a problem with either the serial port settings or the protocol used Power Saving During continuous data transmission it will be noticed that the status signal LED s will dim this is a normal behaviour to save power The status LED s will also extinguish when the tamper switch is held down for more than 5 seconds Page 9 Emlink Programming Repeat Mode Pairing In this mode briefly pressing the right switch of the Emlink1 transmits a pairing signal to another device If the Emlink1 receives a pairing signal from an
5. be poor it is advisable to try another channel Page 10 Hardware Description Inputs 1 amp 2 Listed below are the 4 modes of operation for Inputs 1 amp 2 Mode 1 Self Sensing Normally Open Input In this mode the Emlink1 outputs a sensing pulse to check to see if there is a open or short circuit present Idle state would be represented by an open circuit where an active state would represented by a short circuit Typical examples would be a open collector output from an alarm panel etc Normally Closed Active State Normally Open Idle State A meses Sai a Q Q Mode 2 Self Sensing Normally Closed Input In this mode the Emlink1 outputs a sensing pulse to check to see if there is a open or short circuit present Idle state would be represented by an short circuit where an active state would represented by a open circuit Typical examples would be a magnetic door contact or a PIR sensor Normally Closed Idle State Normally Open Active State Modes 3 amp 4 Positive Trigger either 9 or 18 volts Modes 3 amp 4 accept positive voltages from 0 to 24V DC from an external source For digital switching voltages over 9V Mode3 or 18V Mode 4 switch the Emlink1 into an active triggered state Page 5 Emlink Programming The Emlink1 is configured by a software menu system using the status and signal LED s to show the currently selected options When in configuration mode the currently selected option is shown
6. by 1 or more LED s pulsing twice and the currently selected parameter is shown by one or more of the signal LED s 1 4 To Enter configuration mode hold down switches 1 amp 2 for 3 seconds Once 3 seconds has elapsed all of the Emlink1 s LED s will flash 3 times Depending if you are using a data or non data unit the first option will be the data channel or the input channel For this manual we will assume a data unit is being used While in configuration mode switches 3 work as follows e Switch 1 changes the current menu s option Switch 2 changes the currently selected parameter e Pressing switch 1 for 3 seconds will save all new settings flash all of the Emlink LED s twice and reboot the system e Pressing the tamper switch for 5 seconds exits configuration mode and switches off all LED s without saving new settings Pairing an Input to an output To pair an input to an output is as follows 1 Place both Emlink1 s in configuration mode 2 Select an output channel to pair 1st Emlink1 3 Select an input channel you wish to pair from 2nd Emlink1 4 On the 2nd Emlink1 press the right button The Ist Emlink1 s signal LED 6 should flash twice and the signal LED s 1 5 should increment 5 Save configuration by holding down switch 1 for 3 seconds 6 Test the connection by pressing the input channel switch for half a second and make sure the second box responds 5 Pairing complete Page 11 E
7. come this the Emlink1 can be programmed to transmit a status update at a given period Status updates have 2 main functions 1 If a receiver becomes out of sync with the transmitter i e a power cut receiving automatic status updates will re sync the receiver 2 The receiver can also be programmed to detect missing status updates if 2 or more status updates are missing the receiver generates a tamper fault and the tamper LED will flash twice to indicate a remote tamper fault To enable status updates please refer to the programming section Input channels analogue updates When an Emlink1 transmits a status update it measures the input voltages and transmits this level as a digital value in 0 1V steps The purpose of this feature is for remote data logging etc and has no affect on the inputs previously described Repeat Function An Emlink1 can repeat other Emlink1 s signals The repeating Emlink1 still can use its own inputs and outputs while repeating other units For an Emlink1 to repeat another units data it physically has to receive the first transmission and then re transmit this on the same frequency This is perfectly ok for status updates but for the data channel if a high data through put is required we cannot guarantee its operation RF Channel Selection 7 RF channel channels are available in the 433 434MHz band All Emlink1 units must be on the same channel for them to communicate If a particular channel is found to
8. ess control etc Please refer to the programming guide 2 Pelco P amp D protocol This is mainly used for CCTV telemetry The Emlink1 automatically detects Pelco P or D and has built in support to pair Pelco AUX commands to any of the Emlink1 s 3 outputs See programming section 3 Open protocol This protocol has no input filtering and will transmit any data sent through the RS232 or RS485 lines Care needs to be taken with the hardware connections to prevent the Emlink1 permanently transmit ting data because of poorly connected cables It is advisable to use the above protocols Emlink amp Pelco if possible Page 13 Hardware Layout Aerial Connector Programming Connector Signal LED s Relay 2 z Relay 1 2 Q Tamper Rela e Q 9 z 0 Programming Switches Es Z Q Output Z Q Z 0 Z 0 lt lt CI gt lt Input 1 CI T Input2 Output Ys ad w x lt gt a seeeegesS EMLINK1 433MHz Wireless Interface CI Tampe ka fa 3 n n gt w RS232 RS485 lt D D D D D D D D D D C Status Channel LED s Data channel only on certain models Page 4 Additional Features Status Updates When an Emlink1 s inputs change it automatically transmits an status update This is a normal procedure but if the inputs do not change for a while the receiver does not know if the transmitter is still functioning correctly To over
9. he RS232 and RS4835 are listed below RS485 RS232 DI B 0 Rx Receive Data E Dia 0 Tx Transmit Data ai Q B Q CTS Clear To Send Q a 0 RTS Request To Send OV 0 OV Aerial Connector A threaded M4 connector for mounting of the rubber duck aerial Please ensure the aerial has its supplied rubber washer fitted between the case and aerial and that the aerial is done up hand tight to create a waterproof seal If the washer is not fitted or the aerial is loose possible water damage may occur which is not covered under the product guarantee Programming Connector The programming connector is for firmware upgrades and PC configuration of the Emlink1 Do not connect anything to this connector other than the recommended programming tool Please contact your supplier for purchase information on the PC configuration programming tool if required Page 7 Specifications Electrical Operating voltage 9 24V DC Max Operating current Idle 25mA Max Operating current All Relays amp LED s 85mA Max Relays Max working voltage 30V AC DC Relay contact type Volt Free Relay 1 amp 2 Max current 1A Relay 3 tamper relay max current 500mA Input 1 amp 2 voltage 25V Max Input 1 amp 2 resistance 11 2K Ohms Radio Operating frequencies 433 32 434 52MHz Transmit power lt 10mW Radio data Rate 19 04 KHz Deviation 20KHz SSB Bandwidth 40KHz SSB Data Channel Only on certain models Interface type RS232
10. itches 1 amp 2 together for a brief second the Emlink1 enters Site Survey mode Site Survey mode only sends out a beacon signal and does not control any of the Emlink1 s outputs To exit this mode again press switches 1 amp 2 for a brief second or replace the box cover for 5 seconds It is only advisable to enter one unit into site survey mode at any particular time Channel 1 or 2 Input Test Holding down either switch 1 or 2 for half a second sends the corresponding channel ON signal Any receiving device paired to this channel will activate its corresponding outputs Again this is useful for a engineer to check a channel is working correctly Tamper switch By holding the tamper switch down for 5 seconds this simulates the box lid being closed and switches off all of the internal status LED s The Emlink will also send a status packet on the tamper switch changing state There is also a 1 second delay when you release the tamper switch before the status LED s become ac tive Holding down the tamper switch while in configuration mode for 5 seconds exits configuration mode without saving any new changes Page 8 General Description The Emlink1 is a full featured 433MHz wireless interface designed for short range transmissions The heart of the Emlink1 is the XE1205 radio transceiver which gives the Emlink1 full bi directional communication for its inputs outputs serial data and repeat functions Cased in an IP6
11. mlink Programming Tamper Third Channel Pairing In this mode briefly pressing the right switch of the Emlink1 transmits a pairing signal to another device If the Emlink1 receives a pairing signal from another device signal LED6 will flash twice and the bottom 5 signal LED s will incre ment by Holding down the right switch for more than 3 seconds clears any previously paired devices from this channel It is only possible to pair a data channel with another data channel Listed below is the LED states for the data channel pairing Tamper Third Channel Local Tamper Switch Enable or disable local tamper switch This does not affect the local switches state being transmitted to other Emlink1 interfaces The options are as follows Tamper Switch Flashing LED s Static LED s Disabled Tamper Signal LED 6 Signal LED 1 on Enabled Tamper Signal LED 6 Signal LED 2 on Page 18 Emlink Programming Data Channel Pairing In this mode briefly pressing the right switch of the Emlink1 transmits a pairing signal to another device If the Emlink1 receives a pairing signal from another device signal LED6 will flash twice and the bottom 5 signal LED s will incre ment by Holding down the right switch for more than 3 seconds clears any previously paired devices from this channel It is only possible to pair a data channel with another data channel Listed below is the LED states for the data channel pairing Pai
12. n this mode the normal state is Normally Open The only sup ported mode for this channel is momentarily Note When the local tamper switch is disabled its status is still transmitted to other Emlink1 devices Page 17 EMLINK 1 User Manual Issue 1 0 Hardware Description Outputs 1 amp 2 Both outputs are volt free with normally open normally closed contacts and are capable of switching loads of up to 1A 30V Under software control these outputs can be configured to work in either momentary toggle or timer mode The electrical connections are as follows Relay Outputs 1 amp 2 Normally Closed NC i Common Com O D Normally Open NO Output 3 Tamper Relay Output 3 has volt free contacts and can switch up to 500mA 30V This output can be configured to work as either a tamper circuit Energised normally closed or a third channel Normally open Please refer to the programming section to configure this output The electrical connections are as follows Tamper Output 3 Common Com Normally Open NO Power Supplies The Emlink1 works from a 9 24V Max DC power supply The use of a regu lated or unregulated DC power supply is permitted providing the voltage does NOT exceed 24V DC An unregulated 24V DC power supply will produce a higher voltage than 24V and will cause damage to the Emlink1 The Emlink1 is also reverse polarity protected If using a separate power supply
13. nk1 hold down the right switch and wait for the signal LED s to increment from to 6 this is a warning stating all settings are about to be erased When the 6th LED is on there will be a short pause followed by the Emlink1 flashing all its LED s before rebooting Once the Emlink1 has rebooted it will have restored its factory defaults and erased any previously paired devices Page 21 Emlink1 Programming Input Channels 1 amp 2 Internal Input To Output Pairing The Emlink1 has an option to pair its own input to its own output One good reason for doing this is to use the Emlink1 as a timer but still transmit its status to other units You can only pair input 1 to output 1 or input 2 to output 2 The option are Input Output Pair Flashing LED s Static LED s Input Output Enabled Input x Signal LED 5 Signal LED 1 On Input Output Disabled Input x Signal LED 5 Signal LED 1 Off Note Input x Input 1 or 2 Output Channels 1 amp 2 Pairing In this mode the Emlink1 accepts a pairing signal from another Emlink1 Only inputs can be paired to an output unless the data channel has been configured for either the pelco or Emlink protocol For each new paired device up to 5 units per channel the signal LED s 1 5 increment Holding down the right switch for over 3 seconds clears any previously paired devices on the currently selected output To pair a Pelco Aux command to an output insure that Pelco is al
14. or RS485 Baud rate 2400 19200 Protocols Emlink Pelco P amp D Mechanical 115 x 65 x 40mm Overall size with aerial and grommet 305 x 65 x 40mm Case rating IP65 Case size without aerial and grommet Environmental Temperature range 10 to 70 Degrees Relative humidity 95 non condensing Page 22 Emlink1 Programming Output Channels 1 amp 2 Operational Modes The Emlink1 outputs can operate in 3 modes Momentarily Toggle or Timer 1 Momentarily means if any paired input is triggered the relay output is switched on 2 Toggle mode will cause its output to flip on detection of any positive going signal from a paired device 3 In timed mode any positive going signal from a paired device will either start the timer or reset the timer period to the beginning Output Mode Flashing LED s Static LED s Output x Signal LED 6 Signal LED 1 Toggle Output x Signal LED 6 Signal LED 2 Output x Signal LED 6 Signal LED 3 Note Output x Output LED 1 or 2 Output Channels 1 amp 2 Timer Periods The Emlink1 allows various time periods per channel from 1 second to 30 min utes Listed below is the various timer periods Note Output x Output LED 1 or 2 Page 16 Emlink Programming Restore Factory Settings This option resets the Emlink1 back to factory default and erases any previously paired devices When selected all of the status LED s will flash together To reset the Emli
15. other device signal LED 6 will flash twice and the bottom 5 signal LED s will incre ment Holding down the right switch for more than 3 seconds clears any previ ously paired devices from this channel When pairing a Emlink1 repeat all func tions from the Emlink1 will be repeated Up to 5 Emlink1 units can be repeated Listed below is the LED states for repeat mode pairing Pair Data Channel Flashing LED s Static LED s 1 device Paired Input 1 amp 2 alternating to Output 1 amp 2 LED s Signal LED 1 2 devices Paired Input 1 amp 2 alternating to Output 1 amp 2 LED s Signal LED 2 3 devices Paired Input 1 amp 2 alternating to Output 1 amp 2 LED s Signal LED 3 4 devices Paired Input 1 amp 2 alternating to Output 1 amp 2 LED s Signal LED 4 5 devices Paired Input 1 amp 2 alternating to Output 1 amp 2 LED s Signal LED 5 RF Channel Selection The Emlink1 has 7 RF channels and defaults to channel 5 Below is a list of all the channel numbers and there corresponding frequencies Channel 1 433 32MHz Signal LED 1 Page 20 Emlink Programming Data Channel Protocol Continued Listed below is the LED states for the data channel protocol Protocol Static LED s Emlink Protocol Signal LED 1 Pelco P amp D Signal LED 2 Open Protocol Signal LED 3 Input Channels 1 amp 2 Transmit Pairing Signal When input channels 1 or 2 are flashing The Emlink1 is in Send Pairing Signal mode B
16. r Data Channel Flashing LED s Static LED s 1 device paired Data LED only Signal LED 1 2 devices paired Data LED only Signal LED 2 3 devices paired Data LED only Signal LED 3 4 devices paired Data LED only Signal LED 4 5 devices paired Data LED only Signal LED 5 Data Channel Set Baud Rate In this mode briefly pressing the right switch changes the baud rate from 2400 to 19200 for the RS232 RS485 port The baud rate must match the other communi cating equipment s baud rate to function correctly Listed below is the LED states for the different baud rates Baud Rate Flashing LED s Static LED s 2400 Baud Data Signal LED 6 Signal LED 1 4800 Baud Data Signal LED 6 Signal LED 2 ig o 9600 Baud Data Signal LED 6 Signal LED 3 19200 Baud Data Signal LED 6 Signal LED 4 Page 12
17. ready config ured before entering configuration mode Press the Aux channel you wish to pair on the Pelco interface and the Emlink1 will learn its address and Aux channel Pair Outputs 1 or 2 Flashing LED s Static LED s 1 device paired Output x LED only Signal LED 1 2 devices paired Output x LED only Signal LED 2 3 devices paired Output x LED only Signal LED 3 4 devices paired Output x LED only Signal LED 4 5 devices paired Output x LED only Signal LED 5 Note Output x Output LED 1 or 2 Page 15 Main Features Repeat mode 7 RF channels Site Survey mode Easy Pairing Menu Encrypted protocol 12 24V DC operation 433MHz licence free Signal Strength Meter 1KM Range Line of sight 3 x Volt Free Relay Outputs 2 x Analogue Digital Inputs RS232 RS485 Data Channel IP65 All Weather Rated Enclosure Momentary Toggle amp Timer outputs Emlink Pelco D amp P and open protocols Timer outputs from 1 second to 30 minutes Internal Input to Output Pairing For timer function Missing Status Update Monitoring Signal Jamming Page 2 Basic Functions While the Emlink1 is in normal operation the 3 PCB switches have some engineer friendly features listed below Site Survey Mode This mode sends out a beacon signal every second to assist the engineer in find ing an ideal location for installing the Emlink1 You should aim for a minimum of 2 3 bars of signal strength for a reliable link By pressing sw
18. www emcelr co uk Kohs ce Emlink1 Programming Output Channels 1 amp 2 Relay Test The Emlink1 has a build in relay test function When the output and signal LED s 5 amp 6 are flashing pressing the right switch will turn on the outputs relay and signal LED 1 Tamper Output 3rd Channel Overview The tamper channel can work as a tamper relay or a third channel Pairing the tamper channel to any local or remote tamper functions automatically configures the third channel s output into tamper mode In tamper mode the relay is perma nently energised while no tamper fault has been detected This is a fail safe sys tem to prevent a power failure not showing a tamper fault Setting any of the following will configure the third channel as a tamper channel 1 Enable local tamper switch 2 Enable missing status updates 3 Pair any remote Emlink1 s tamper channel It is also possible to pair a standard input from a remote Emlink1 to the tamper channel A standard input from a remote Emlink1 will not switch the third chan nel into a tamper channel but it can be used as another tamper input When a remote input is being used on a tamper channel triggering the input will switch off the tamper relay i e the signal is inverted This can be a useful feature if you wish to report back a remote tamper state from a bell box or PIR etc If none of the above have been enabled or paired the tamper relay will work as a third channel I
19. y briefly pressing the right button the signal LED s will flash a TX signal Flashing from middle outwards to send the pairing signal to another Emlink1 device The receiving device will flash its signal LED 6 to indicate the reception of this pairing signal Send Pairing Signal Flashing LED s Static LED s Pair Input 1 or 2 Input LED s 1 or 2 Input Channels 1 amp 2 Set Input Mode Four possible modes are available See Hardware Description and are listed below Input 1 or 2 Mode Flashing LED s Static LED s Self Sense N 0 Input x Signal LED 6 Signal LED 1 Self Sense N C Input x Signal LED 6 Signal LED 2 Positive Trig 9V Input x Signal LED 6 Signal LED 3 Positive Trig 18V Input x Signal LED 6 Signal LED 4 Note Input x Input LED 1 or 2 Page 14 Emlink Programming Tamper Third Channel Status Update Monitoring Enable or disable status update monitoring When enabled any missing status updates will generate a tamper fault and flash the tamper LED twice Status Update Monitoring Flashing LED s Static LED s Disabled Tamper Signal LED 5 Signal LED 1 on Enabled Tamper Signal LED 5 Signal LED 2 on Tamper Third Channel Relay Test The Emlink1 has a build in relay test function When the tamper and signal LED s 5 amp 6 are flashing pressing the right switch will turn on the relay and signal LED 1 Status Update Period Enabling the status updates forces the Emlink