Home

Testo 610 humidity temperature meter user manual

image

Contents

1. Digit 119x46x25 mm inc protection cap 0 5 C 0 9 F 2 5 rH 5 95 rH Weight 90 g inc batteries and o rate protection cap Os Directives standards and tests EC Directive 89 336 EEC Warranty Duration 2 years Warranty conditions see guarantee card 14 Product description Product description At a glance First steps Protection cap Park position 2 Humidity temperature sensor Display 4 Control keys Battery compartment on rear gt Inserting batteries 1 To open the battery compartment push the battery cover down 2 Insert batteries 2x 1 5 V type AAA Observe the polarity 3 To close the battery compartment push the battery cover back on gt Basic settings configuration mode Adjustable functions Unit of temperature C F Auto off function OFF ON instrument switches off automatically if no key is pressed for 10 minutes 1 When switching the instrument on press and hold until A and appear on the display configuration mode The adjustable function is displayed The current setting flashes 2 Press A several times until the desired setting flashes 3 Press D to confirm the input 4 Repeat steps 2 and 3 for all functions The instrument changes to measuring mode Using the product 15 Using the product B To guarantee correct readings Keep temperature and humidity Bas sources which may falsify the me
2. Soap suds if it is dirty Do not use aggressive cleaning agents or solvents Tips and assistance 17 Tips and assistance Questions and answers HS Question Possible causes solutions Hior Lo Readings outside the measuring range too high too low Keep to the permitted measuring range Eo Residual capacity lt 10 min Change batteries If we could not answer your question please contact your dealer or Testo Customer Service Contact details can be found on the guarantee card or on the Internet at www testo com 18 Notes testo AG Postfach 1140 79849 Lenzkirch Testo StraBe 1 79853 Lenzkirch Telefon 07653 681 0 Fax 07658 681 100 E Mail info testo de Internet http Awww testo com 0973 6100 02 Sh dr 28 03 2007
3. asurement e g hands away from the sensor gt Switching the instrument on gt Press Measuring mode is opened gt Switching the display light on y The instrument is switched on gt Press The display light goes out automatically if no key is pressed for 10 seconds Changing the parameter Adjustable units relative humidity td dew point temperature wb wet bulb temperature gt Press until the desired parameter appears gt Changing the display view Adjustable views Current reading Hold Readings are held Max Maximum values since the instrument was last switched on or last reset Min Minimum values since the instrument was last switched on or last reset gt Press S several times until the desired view appears gt Resetting Max Min values 1 Press several times until the desired view appears 2 Press S and hold until appears 3 Repeat steps 1 and 2 for all values that are to be reset gt Switching the instrument off gt Press and hold until the display goes out 16 Maintaining the product Maintaining the product gt Changing batteries 1 To open the battery compartment push the battery cover down 2 Remove used batteries and insert new batteries 2x 1 5 V type AAA Observe the polarity 3 To close the battery compartment push the battery cover back on gt Cleaning the housing gt Clean the housing with a moist cloth
4. ment gt Only operate the measuring instrument properly for its intended purpose and within the parameters specified in the technical data Do not use force Never store the product together with solvents acids or other aggressive substances Only carry out the maintenance and repair work that is described in the documentation Follow the prescribed steps when doing so Use only OEM spare parts from Testo Protecting the environment gt Take faulty rechargeable batteries as well as spent batteries to the collection points provided for them Send the product back to Testo at the end of its useful life We will ensure that it is disposed of in an environmentally friendly manner Specifications 13 Specifications Functions and use The testo 610 is a humidity temperature measuring instrument It is normally used to measure the humidity in offices and storerooms buildings and greenhouses Technical data Measurement data Further instrument data Sensors Protection class IP20 Testo humidity sensor Ambient conditions NTC temperature sensor 10 50 C 14 122 F Parameters Storage transport conditions C F rH wet bulb td 40 70 C 40 158 F Measuring ranges Voltage supply 10 50 C 14 122 F 0 100 rH 2x 1 5 V type AAA Resolutions Battery life 0 1 C 0 1 F 0 1 rH 200 h without display light Accuracies Dimensions Nominal temperature 25 C 1
5. testo 610 Bedienungsanleitung de Mode d emploi fr Manual de instrucciones es Manuale di istruzioni it Manual de instru es pt Short manual testo 610 11 Short manual testo 610 Protection cap Park position 2 Humidity temperature sensor E55 Display 4 Control keys Battery compartment on rear Basic settings Instrument off gt press and hold 2s gt select with A confirm with S lt Unit of temperature C F gt Auto off function OFF ON Switching the instrument on Press Switching the display light on for 10s Instrument on gt press Select display size Instrument on gt select with relative humidity td dew point temperature wb wet bulb temperature Select display mode Instrument on gt select with fee Current reading gt Hold Readings are held gt Max Maximum values gt Min Minimum values Switching the instrument off Instrument on gt press and hold 2s 12 Safety and the enviroment Safety and the environment About this document gt Please read this documentation through carefully and familiarise yourself with the product before putting it to use Keep this document to hand so that you can refer to it when necessary Hand this documentation on to any subsequent users of the product Pay particular attention to information emphasised by the following symbols E Important Avoid personal injury damage to equip