1. Communication Interface for SMA Inverters SMA SPEEDWIRE WEBCONNECT DATA MODULE Installation Manual Com Bd MD SWWEBCONDM lA en 11 98 0051211 Version 1 1 Cen SMA Solar Technology AG Table of Contents Table of Contents Information on this 2 ISC EE E SC A een ee 2 2 Qualifications of Skilled 2 9 2 4 Operating 3 5 Delivery nn 3 1 Order Option Speedwire Webconnect Data Module Pre Installed in the 3 2 Order Option Speedwire Webconnect Data Module as RONE I nen Ee 4 Product 4 1 Speedwire Webconnect Data Module 22 Type label EE ee 9 e TE EE Sl DEVICE sace WE ee 5 2 Cable Requirements and Information on Routing 5 3 Installing the Speedwire Webconnect Data Module in the Inverter 5 4 Connecting the Speedwire Webconnect Data Module 6 1 Commissioning a Large Plant with Cluster Controller 6 2 Commissioning a Small Pont 6 3 Managing a Small Plant with Sunny Explorer
2. 6 3 1 Functions and Parameter Settings in Sunny Explorer 6 3 2 Connection to Sunny Installation Manual SWWEBCONDM A en 1 1 19 Table of Contents SMA Solar Technology AG 6 4 Plant Registration in Sunny 25 6 4 1 Registering a Small Plant in Sunny Portal 25 6 4 2 Registering a Large Plant with Cluster Controller in STA e 26 7 Decsmmissioninga s u re 27 7 1 Disassembling the Speedwire Webconnect Data Module 27 7 2 Disposing of the Speedwire Webconnect Data Module 27 8 28 9 Technical Dalias ida das 29 IO hw Gok a tal d de CR UR Nb e ats 30 4 SWWEBCONDM A en 1 1 Installation Manual SMA Solar Technology AG 1 Information on this Document 1 Information on this Document Validity This document is valid for device type SWDM 10 GR1 with firmware version 1 00 00 R or higher Target Group This document is for skilled persons Only skilled persons with appropriate qualification are allowed to perform the tasks set forth in this document see Section 2 2 Qualifications of Skilled Persons page 9 Additional Information Links to additional information can be found at www SMA Solar com Document title Document type Firmware Update with SD Card Technical description Symbols Symbol A DANGER I
3. Australia Austria Belgium Bulgaria China Czech Republic Denmark France Germany Greece Hungary India Italy Japan Korea Luxembourg Netherlands 30 Company name SMA Australia Pty Ltd See Germany SMA Benelux bvba sprl See Greece SMA Beijing Commercial Company Ltd SMA Central amp Eastern Europe s r o See Germany SMA France S A S SMA Solar Technology AG SMA Hellas AE See Czech Republic SMA Solar India Pvt Ltd SMA Italia S r l SMA Japan K K SMA Technology Korea Co Ltd See Belgium See Belgium SWWEBCONDM lA en 1 1 Subsidiary Sydney Mechelen Beijing Prague Lyon Niestetal Athens Mumbai Milan Tokyo Seoul SMA Service Line Toll free for Australia 1800 SMA AUS 1800 762 287 International 61 2 9491 4200 32 15 286 730 86 10 51501685 602 420 235 010 417 Sunny Boy Sunny Mini Central Sunny Tripower Inverters 33 472 09 04 40 Communication 33 472 09 04 41 Sunny Island 33 472 09 04 42 Sunny Central 33 472 09 04 43 Sunny Boy Sunny Mini Central Sunny Tripower Inverters 49 561 9522 1499 Communication 49 561 9522 2499 SMS with R ckruf 49 176 888 222 AA Sunny Island 49 561 9522 399 Sunny Central 49 561 9522 299 30 210 9856 666 91 22 61713844 39 02 89347 299 81 3 3451 9530 82 2 508 8599 Installation Manual SMA Solar Technology AG 10 Contact Poland Portugal Romania
4. word mark and logos are registered trademarks owned by Bluetooth SIG Inc and any use of such marks by SMA Solar Technology AG is under licence GR Code is a registered trademark of DENSO WAVE INCORPORATED SMA Solar Technology AG Sonnenallee 1 34266 Niestetal Germany Tel 49 561 9522 0 Fax 49 561 9522 100 www SMA de E Mail infoGSMA de 2004 to 2013 SMA Solar Technology AG All rights reserved Installation Manual SWWEBCONDM A en 1 1 35 SMA Solar Technology SMA Solar Technology AG www SMA de SMA Australia Pty Ltd www SMA Australia com au SMA Benelux bvba sprl www SMA Benelux com SMA Beijing Commercial Company Ltd www SMA China com cn SMA Central 8 Eastern Europe s r o www SMA Czech com SMA France S A S www SMA France com SMA Hellas AE www SMA Hellas com SMA Ib rica Tecnolog a Solar S L U www SMA Iberica com SMA Solar India Pvt Ltd www SMA India com SMA Italia S r l www SMA Italia com SMA Japan K K www SMA Japan com SMA Technology Korea Co Ltd www SMA Korea com SMA Middle East LLC www SMA Me com SMA Portugal Niestetal Services Unipessoal Lda www SMA Portugal com SMA Solar Thailand Co Ltd www SMA Thailand com SMA Solar UK Ltd www SMA UK com
5. Slovakia Spain Switzerland Thailand United Arab Emirates United Kingdom Other countries Installation Manual See Czech Republic SMA Solar Technology Portugal Unipessoal Lda See Czech Republic See Czech Republic SMA Ib rica Tecnolog a Solar S L U See Germany SMA Solar Thailand Co Ltd SMA Middle East LLC SMA Solar UK Ltd International SMA Service Line Lisbon Barcelona Bangkok Abu Dhabi Milton Keynes Niestetal 351 2 12 37 78 60 34 900 14 22 22 662 670 6999 971 2 698 5080 44 1908 304899 00800 SMA SERVICE 800 762 7378423 SWWEBCONDM A en 1 1 31 SMA Solar Technology AG Legal Provisions Legal Provisions The information contained in this document is the property of SMA Solar Technology AG Publishing its content either partially or in full requires the written permission of SMA Solar Technology AG Any internal company copying of the document for the purposes of evaluating the product or its correct implementation is allowed and does not require permission SMA Factory Warranty The current warranty conditions come enclosed with your device These are also available online at www SMA Solar com and can be downloaded and are available on paper from the usual sales channels if required Trademarks All trademarks are recognised even ifthese are not marked separately Missing designations do not mean that a product or brand is not a registered trademark The Bluetooth
6. Router Figure 5 Small plant with two inverters in star topology example 14 SWWEBCONDM A en 1 1 Installation Manual SMA Solar Technology AG 4 Product Description Use in Large Plants with Cluster Controller The Speedwire network can be set up optionally with linear star or tree topology In large plants with Cluster Controller the data exchange with Sunny Portal does not take place via the individual inverters but centrally via the Cluster Controller see user manual of the Cluster Controller and user manual of the Cluster Controller in Sunny Portal i Deactivation of the inverter Webconnect function in large plants with Cluster Controller In large plants with Cluster Controller communication with Sunny Portal takes place via the Cluster Controller itself e For optimum operation of large plants with Cluster Controller deactivate the Webconnect function of the inverters with installed Speedwire Webconnect data module see user manual of the Cluster Controller Sunny Portal Sunny Boy Sunny Boy Router Internet Lokal Speedwire Network Sunny Explorer Figure 6 Large plant in linear topology example Installation Manual SWWEBCONDM A en 1 1 15 4 Product Description SMA Solar Technology AG 4 2 Type Label The type label clearly identifies the Speedwire Webconnect data module The type label is located in the right hand top corner at the front of the S
7. or is pre installed in the inverter f A Figure 3 Components of the Speedwire Webconnect data module Description Bo Network socket A Network socket B ioe Ribbon cable plug Ribbon cable Type label 12 SWWEBCONDM IA en 1 1 Installation Manual SMA Solar Technology AG 4 Product Description Label with PIC and RID for Registration of a Small Plant in Sunny Portal To activate the Speedwire Webconnect data module of a small plant in Sunny Portal you will need the PIC and RID numbers printed on the supplied label After installation of the Speedwire Webconnect data module attach the label on the exterior of the inverter in the vicinity of the type label Keep the other label in a safe place for future reference Use in Small Plants with a Maximum of Four Inverters A small plant in Sunny Portal can consist of a maximum of four inverters with installed Speedwire Webconnect data module In small plants Speedwire network can be set up optionally with linear star or tree topology A PC with the Sunny Explorer software is connected to the router or switch depending on the plant Sunny Boy Sunny Boy Sunny Portal Local Speedwire network Cluster Controller user interface Figure 4 Small plant with two inverters in linear topology example Installation Manual SWWEBCONDM A en 1 1 13 4 Product Description SMA Solar Technology AG Sunny Boy Sunny Boy Sunny Portal Internet
8. allation Manual SWWEBCONDM A en 1 1 23 6 Commissioning SMA Solar Technology AG 6 3 Managing a Small Plant with Sunny Explorer 6 3 1 Functions and Parameter Settings in Sunny Explorer The following functions for plant management in Sunny Explorer are available e Overview of the plant status e Graphic display of key plant data device data and energy values e Parameterisation of individual devices or an entire device class e Simple diagnostics thanks to display of faults and events e Data export of inverter energy values and events in CSV format e Device updates You can change the following parameters in Sunny Explorer e Device name of the inverter e Automatic IP configuration On Off e DNS IP gateway IP IP address subnet mask e Webconnect function On Off 6 3 2 Connection to Sunny Explorer Requirements The plant must be in operation see Section 6 2 Commissioning a Small Plant page 23 Procedure 1 Connect the computer to the plant router with a network cable 2 Start Sunny Explorer and create plant see Sunny Explorer user manual 24 SWWEBCONDM A en 1 1 Installation Manual SMA Solar Technology AG 6 Commissioning 6 4 Plant Registration in Sunny Portal 6 4 1 Registering a Small Plant in Sunny Portal Requirements O D D The small plant must be in operation see Section 6 2 Commissioning a Small Plant page 23 PIC and RID must be available for the Speedwire Webconnect data module Yo
9. ct your specialist dealer if the delivery is incomplete or damaged B C D Figure 2 Components included in delivery Speedwire Webconnect data module as retrofit kit Lem Quantity A ft Speedwire Webconnect data module Installation manual c n Cablegiand ID 2 Label with PIC and RID for registration of a small plant in Sunny Portal Installation Manual SWWEBCONDM A en 1 1 11 4 Product Description SMA Solar Technology AG A Product Description 4 1 Speedwire Webconnect Data Module The Speedwire Webconnect data module is a Speedwire communication interface with Webconnect function for inverters Speedwire is a cable based type of communication based on the Ethernet standard and the communication protocol SMA Data2 This enables inverter optimised 10 100 Mbit data transmission between Speedwire devices in PV plants The Webconnect function enables data transmission between the inverters of a small plant and the Internet portal Sunny Portal In Sunny Portal a maximum of four inverters can be combined in a Sunny Portal plant The Speedwire Webconnect data module performs the following tasks e Set up of a Speedwire network in small and large plants e Direct data exchange with Sunny Portal In small plants via a router with Internet connection In large plants via the Cluster Controller Data exchange with Sunny Explorer from version 1 05 The Speedwire Webconnect data module is available as a retrofit kit
10. erter installation manual Observe the waiting time to allow the capacitors to discharge 2 Loosen the screw of the display until the display can be flipped up 3 Flip the display up until it clicks into place Push the pre mounted filler plug out of the second hole from the left in the inverter enclosure Installation Manual SWWEBCONDM lA en 1 1 19 5 Connection SMA Solar Technology AG 5 Attach the cable gland to the enclosure opening with the counter nut 6 Insert the Speedwire Webconnect data module and slide the ribbon cable upwards behind the display The key on the top edge of the Speedwire Webconnect data module must fit into the hole in the plastic retainer in the inverter 7 Fasten the Speedwire Webconnect data module hand tight with the hexagon socket screw 8 Flip the display down 9 Plug the ribbon cable plug onto the centre connector strip 20 SWWEBCONDM IA en 1 1 Installation Manual SMA Solar Technology AG 5 Connection 5 4 Connecting the Speedwire Webconnect Data Module Requirements The network cables must be pre assembled according to the plant topology and the cable requirements see Section 5 2 Cable Requirements and Information on Routing page 18 Procedure 1 Flip the display up until it clicks into place 2 Unscrew the swivel nut of the cable gland on the inverter 3 Press the seal out of the cable gland from the inside 4 Lead the networ
11. f the cable gland 8 Pull the cable gland and network cables out of the inverter 9 Release the screw of the Speedwire Webconnect data module and remove the module 10 Flip the display down and fasten the display screw hand tight 11 Sealthe enclosure opening of the inverter with the corresponding filler plug 12 Close the inverter see inverter installation manual M The Speedwire Webconnect data module is disassembled 7 2 Disposing of the Speedwire Webconnect Data Module e Dispose of the Speedwire Webconnect data module in accordance with the regulations for the disposal of electronic waste applicable at the site of installation Installation Manual SWWEBCONDM A en 1 1 27 8 Troubleshooting SMA Solar Technology AG 8 Troubleshooting Problem Cause and corrective measures The Speedwire Webconnect There is no Speedwire connection data module cannot be Coredive measures accessed Ensure that all network cable plugs are inserted and locked Ensure that all inverters in the plant are in operation Make sure that the plant router is switched on Make sure that the ribbon cable plug of the Speedwire Webconnect data module is correctly plugged into the centre connector strip in the inverter The inverter does not recognise the Speedwire Webconnect data module Corrective measures e Perform firmware update on the inverter see technical description Firmware Update with SD Card at www SMA Solar com Firewa
12. he Speedwire Webconnect Data Module in the Inverter page 19 The Speedwire Webconnect data modules must be connected see Section 5 4 Connecting the Speedwire Webconnect Data Module page 21 The Cluster Controller must be connected to the Speedwire network in accordance with the desired network topology see installation manual of the Cluster Controller Procedure 1 Commission all inverters with installed Speedwire Webconnect data module see inverter installation manual 2 D Deactivating the Webconnect function of the inverters In large plants with Cluster Controller communication with Sunny Portal takes place via the Cluster Controller itself For optimum operation of large plants with Cluster Controller deactivate the Webconnect function of the inverters with installed Soeedwire Webconnect data module see user manual of the Cluster Controller 6 2 Commissioning a Small Plant Requirements O A Speedwire Webconnect data module must be installed in the inverter see Section 5 3 Installing the Speedwire Webconnect Data Module in the Inverter page 19 The Speedwire Webconnect data module must be connected see Section 5 4 Connecting the Speedwire Webconnect Data Module page 21 At least one inverter must be connected to the router DHCP must be enabled for the router Procedure Commission all inverters with installed Speedwire Webconnect data module see inverter installation manual Inst
13. ic assignment of IP configurations Elctrostafic Discharge Electronic Solar Switch The Electronic Solar Switch and the DC connectors form a DC load disconnect unit Product Identification Code Identification key for registration in Sunny Portal Registration Identifier Registration key for registration in Sunny Portal E memet Figures The figures in this document may deviate slightly for inverter types Sunny Tripower and Windy Boy Installation Manual SWWEBCONDM A en 1 1 7 2 Safety SMA Solar Technology AG 2 Safety 2 1 Intended Use The Speedwire Webconnect data module is a Speedwire communication interface with Webconnect function for inverters Speedwire is a cable based type of communication based on the Ethernet standard and the communication protocol SMA Data2 This enables inverter optimised 10 100 Mbit data transmission between Speedwire devices in PV plants The Webconnect function enables data transmission between the inverters of a small plant and the Internet portal Sunny Portal In Sunny Portal a maximum of four inverters can be combined in a Sunny Portal plant The Speedwire Webconnect data module performs the following tasks e Set up of a Speedwire network in small and large plants e Direct data exchange with Sunny Portal In small plants via a router with Internet connection In large plants via the Cluster Controller e Data exchange with Sunny Explorer from version 1 05 The Speedwire Webco
14. issioning of electrical devices and plants e Knowledge of how to deal with the dangers and risks associated with installing and using electrical devices and plants e Knowledge of all applicable standards and directives e Knowledge of how an inverter works and is operated e Knowledge of and adherence to this document and all safety precautions 2 3 Safety Precautions Electric Shock Lethal voltages are present in the conductive parts of the inverter e Prior to performing any work on the inverter disconnect the inverter from any voltage sources on the AC and DC sides see inverter installation manual Observe the waiting time to allow the capacitors to discharge Burn Hazards Some parts of the inverter enclosure can get hot during operation e During operation touch the inverter on the enclosure lid only Environmental Influences When closed and with the ESS plugged in the inverter has the degree of protection IP65 The inverter is thus protected against dust intrusion and water penetration Dust intrusion and water penetration can damage the inverter e When the ESS is not plugged in the inverter must be protected against dust and water e Firmly plug the ESS in again after performing any work on the inverter Electrostatic Discharge By touching electronic components you can damage or even destroy the inverter through electrostatic discharge ESD e Earth yourself before touching any inverter components Installati
15. k cables from the outside into the inverter through the loose swivel nut and the cable gland 5 Remove one filler plug from the seal for each network cable e Installation Manual SWWEBCONDM A en 1 1 21 5 Connection SMA Solar Technology AG 10 11 12 18 14 22 Insert the network cables into the seal Route the network cable plugs into the inverter to the network f sockets Push the seal into the cable gland Make sure that any unused cable openings sealed with filler plugs Screw the swivel nut of the cable gland on lightly Insert the network cables into the network sockets This can be done in any order Fasten the swivel nut on the cable gland hand tight This will secure the network cables in place Flip the display down and fasten it hand tight with the display screw Close the inverter see inverter installation manual In a small plant connect at least one inverter directly to the router depending on the plant topology In a large plant with Cluster Controller connect the Cluster Controller to the Speedwire network depending on the required network topology see the Cluster Controller installation manual SWWEBCONDM A en 1 1 Installation Manual SMA Solar Technology AG 6 Commissioning 6 Commissioning 6 1 Commissioning a Large Plant with Cluster Controller Requirements O Speedwire Webconnect data modules must be installed in the inverters see Section 5 3 Installing t
16. l Requirements O 26 The large plant with Cluster Controller must be in operation see Section 6 1 Commissioning Large Plant with Cluster Controller page 23 Your computer must have an Internet connection The Cluster Controller must be connected to a router with Internet connection see installation manual of the Cluster Controller JavaScript must be activated in the Internet browser In large plants with Cluster Controller carry out registration in Sunny Portal via the user interface of the Cluster Controller see user manual of the Cluster Controller SWWEBCONDM A en 1 1 Installation Manual SMA Solar Technology AG 7 Decommissioning 7 Decommissioning 7 1 Disassembling the Speedwire Webconnect Data Module 1 A DANGER Danger to life due to electric shock when the inverter is opened Death or serious injuries e Disconnect the inverter from voltage sources on the AC and DC sides and open it see the inverter installation manual Observe the waiting time to allow the capacitors to discharge 2 Press the left hand and right hand lock hooks outwards and remove the ribbon cable plug from the centre connector strip of the inverter 3 Loosen the screw of the display until the display can be flipped up 4 Flip the display up until it clicks into place 5 Unscrew the swivel nut of the cable gland 6 Remove the network cables from the Speedwire Webconnect data module 7 Unscrew the counter nut o
17. ll or IP filter settings are not correct Corrective measures e Adjust firewall or IP filter settings see firewall or router manual The Speedwire Webconnect Data Module does not have a valid IP address Corrective measures e Ensure that DHCP is activated in the router or assign a manual IP address to the Speedwire Webconnect data module 28 SWWEBCONDM A en 1 1 Installation Manual SMA Solar Technology AG 9 Technical Data 9 Technical Data General Data Mounting location in the inverter Voltage supply via inverter Mechanical Data Width x height x depth 73 mm x 88 mm x 34 mm Communication Communication interface Speedwire Webconnect Maximum cable length 100 m Connections Type of plug RJA5 Number of RJA5 terminals Ambient Conditions for Storage Transport Relative humidity non condensing 10 100 Installation Manual SWWEBCONDM A en 1 1 29 10 Contact 10 Contact If you have technical problems concerning our products please contact the SMA Service Line We SMA Solar Technology AG will need the following data in order to provide you with the necessary assistance e Type serial number and firmware version of the inverter e Type serial number and firmware version of the Soeedwire Webconnect data module e For large plants serial number and firmware version of the Cluster Controller e For small plants PIC and RID numbers of the Soeedwire Webconnect data module Country
18. ndicates a hazardous situation which if not avoided will result in death or serious injury AA WARNING Indicates a hazardous situation which if not avoided could result in death or serious injury A CAUTION Indicates a hazardous situation which if not avoided could result in minor or moderate injury NOTICE Indicates a situation which if not avoided could result in property damage Information that is important for a specific topic or goal but is not safety relevant Indicates an essential requirement for achieving a specific x Desired result A problem that might occur Installation Manual SWWEBCONDM A en 1 1 5 1 Information on this Document SMA Solar Technology AG Typography Typography Display messages e The value can be read from the Elements of a user interface Energy field Comecon e Select Settings e Enter the value 10 in the Minutes field Elements to be selected Elements to be entered Connects several elements Select Settings gt Date that are to be selected Button Key e Button or key to be selected or Select Next pressed Nomenclature SMA Speedwire SMA Speedwire Webconnect data module Speedwire Webconnect data module SMA Webconnect function Webconnect function 6 SWWEBCONDM lA en 1 1 Installation Manual SMA Solar Technology AG 1 Information on this Document Abbreviations bc DHCP Dynamic Host Configuration Protocol Protocol for the dynam
19. nnect data module is available as a retrofit kit or is pre installed in the inverter The Speedwire Webconnect data module may only be installed in the following inverters with at least firmware version 2 53 SB 2500TLST 21 STP 8000TL 10 WB 3000TL 21 SB 3000TLST 21 STP 10000TL 10 WB 3600TL 21 SB 3000TL 2 1 STP 12000TL 10 WB AOOOTL 2 1 SB 3600TL 2 1 STP 15000TL 10 WB SOOOTL 2 1 SB 4000TL 21 STP 15000TLEE 10 SB 5000TL 21 STP 15000TLHE 10 STP 17000TL 10 STP 20000TLEE 10 STP 20000TLHE 10 For information on the firmware update refer to the Technical Description Firmware Update with SD Card at www SMA Solar com For safety reasons it is not permitted to modify the product or install components that are not explicitly recommended or distributed by SMA Solar Technology AG for this product 8 SWWEBCONDAMH IA en 1 1 Installation Manual SMA Solar Technology AG 2 Safety The enclosed documentation is an integral part of this product e Read and observe the documentation e Keep the documentation in a convenient place for future reference Only use the Speedwire Webconnect data module in accordance with the specifications provided in the enclosed documentation Any other use may result in personal injury or property damage 2 2 Qualifications of Skilled Persons The work described in this document must be performed by skilled persons only Skilled persons must have the following qualifications e Training in the installation and comm
20. on Manual SWWEBCONDM A en 1 1 9 2 Safety SMA Solar Technology AG 2 4 Operating Information Selecting a Suitable Internet Tariff for Small Plants When using the Webconnect function a constant Internet connection is required Depending on the quality ofthe Internet connection the transmission volume for an inverter is between 150 MB and 550 MB per month When using the plant overview in Sunny Portal with live data display there is an additional data volume of 600 kB per hour e SMA Solar Technology AG recommends using an Internet flat rate e Since there is a constant Internet connection to Sunny Portal time based billing systems should be avoided High costs could be incurred 10 SWWEBCONDM A en 1 1 Installation Manual SMA Solar Technology AG 3 Scope of Delivery 3 Scope of Delivery 3 1 Order Option Speedwire Webconnect Data Module Pre Installed in the Inverter Check the scope of delivery for completeness and any visible external damage Contact your specialist dealer if the delivery is incomplete or damaged A B Figure 1 Components included in delivery Speedwire Webconnect data module pre installed in the inverter item Quantity Description Installation manual mn fi Cable gland Label with PIC and RID for registration of a small plant in Sunny Portal 3 2 Order Option Speedwire Webconnect Data Module as Retrofit Kit Check the scope of delivery for completeness and any visible external damage Conta
21. peedwire Webconnect data module Em SMA Solar Technology AG PIC XXXXXXXXXX Type XXXXXXXXXX D XXXXXXXXXX MAC Adress XXXXXXXXXX Figure 7 Layout of the type label tem Explanation WI B Productdesignation S D Serial number ofthe Speedwire Webconnect data module F Hardware version ofthe Speedwire Webconnect data module IG Jm The information on the type label is required for safe use of the Speedwire Webconnect data module and for reference if customer support from the SMA Service Line is needed The type label must be permanently affixed to the Speedwire Webconnect data module Symbols on the Type Label symbol CE marking The product complies with the requirements of the C applicable EU directives 16 SWWEBCONDM A en 1 1 Installation Manual SMA Solar Technology AG 4 Product Description 4 3 Cable Gland The cable gland provides a sturdy tightly sealed connection of the network cables with the inverter enclosure The cable gland also protects the inverter from dust intrusion and moisture penetration AB C D Figure 8 Product description cable gland Description Filler plug Swivel nut B Sea Counter nut Installation Manual SWWEBCONDM A en 1 1 17 5 Connection SMA Solar Technology AG 5 Connection 5 1 Device Overview Description Display with screw Cable route to network sockets Opening in the inve
22. rter enclosure with filler plug Mounting position of the Webconnect data module in the inverter 5 2 Cable Requirements and Information on Routing The cable length and quality have an effect on the signal quality in the Speedwire network Observe the following instructions regarding network cabling D Interference in data transmission due to AC cables When AC cables are in operation they generate an electromagnetic field which may induce interference in network cables during data transmission e the network cables using suitable fastening material observing a minimum clearance of 50 mm to the AC cables Cable requirements Cable length between network network nodes max 100 m Cross section at least 2 x 2 x 0 22 mm or at least 2 x 2 AWG 24 Cable type 100BaseTx CATS with shielding S UTP F UTP or higher UV resistant for outdoor use g 18 SWWEBCONDM A en 1 1 Installation Manual SMA Solar Technology AG 5 Connection Type of plug RJ45 SMA Solar Technology AG recommends the following cable types e For outdoor use SMA COMCAB OUTxxx e For indoor use SMA COMCAB INxxx The cables are available in the lengths xxx 100 m 200 m 500 m and 1 000 m 5 3 Installing the Speedwire Webconnect Data Module in the Inverter 1 Danger to life due to electric shock when the inverter is opened Death or serious injuries e Disconnect the inverter from voltage sources on the and DC sides and open it see the inv
23. ur computer must have an Internet connection JavaScript must be activated in the Internet browser Maximum permissible number of devices for a small plant in Sunny Portal In Sunny Portal you can manage several plants A maximum of four inverters with installed Speedwire Webconnect data module per small plant is permitted Small plant with Speedwire Webconnect data module cannot be combined with other plants If you already have a plant registered in Sunny Portal with another communication device e g Sunny WebBox you will still need to create a separate small plant with Speedwire Webconnect data module It is not possible to combine the Speedwire Webconnect data module and other communication devices within one plant in Sunny Portal Sunny Portal treats the existing plant and the new small plant with Speedwire Webconnect data module as independent plants Create a new small plant with Speedwire Webconnect data module Starting the Plant Setup Assistant in Sunny Portal The Plant Setup Assistant is a step by step guide of the processes required for user registration and the registration of your plant in Sunny Portal 1 2 Open www SunnyPortal com Select Plant Setup Assistant The Plant Setup Assistant opens Follow the instructions of the Plant Setup Assistant Installation Manual SWWEBCONDM A en 1 1 25 6 Commissioning SMA Solar Technology AG 6 4 2 Registering a Large Plant with Cluster Controller in Sunny Porta