1. Depending on the device type some of the monitoring options might not be available Switch Table This tab shows the configuration of the Switch Domain Table Blocked Domain Table Subnet Node Table and Group Tables L Switch devices which are equipped with a 1 x firmware show the L Switch Domain Table L Switch Subnet Node Table and Group Table tabs instead Switch Statistics This tab shows the Packet Forwarding Packet Count and Group Cleared statistics of the node L Switch firmware 1 x displays the L Switch Statistics Tab instead Channel Statistics This tab shows the channel statistics information for all ports of the node L Switch firmware 1 x shows the L Switch Statistics panel instead Version 2 2 LOYTEC electronics GmbH LSD Tool User Manual 12 L Switch Setup This tab shows the L Switch configuration and allows to change the switch configuration like transceiver settings port enabling disabling and management port configuration For L Switch RTR Devices it allows to change the routing mode of the L Switch RTR L Switch firmware 1 x uses the L Switch Info and L Switch Configuration panels instead L IP Setup This tab allows viewing and changing the configuration of an L IP device via the network Configurable options are the IP settings IP address settings host name router mode configuration control of the web server and the transceiver configuration 4 4 Status Log Frame The frame on the bottom
2. LSD Tool User s Manual LOYTEC electronics GmbH Vienna LSD Tool User Manual 2 This page is intentionally left blank Version 2 2 LOYTEC electronics GmbH LSD Tool User Manual 3 Contact LOYTEC electronics GmbH Stolzenthalergasse 24 3 A 1080 Vienna AUSTRIA EUROPE support loytec com http www loytec com Version 2 2 Document No 88067003 LOYTEC MAKES AND YOU RECEIVE NO WARRANTIES OR CONDITIONS EXPRESS IMPLIED STATUTORY OR IN ANY COMMUNICATION WITH YOU AND LOYTEC SPECIFICALLY DISCLAIMS ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE No part of this publication may be reproduced stored in a retrieval system or transmitted in any form or by any means electronic mechanical photocopying recording or otherwise without the prior written permission of LOYTEC L Chip LC7093 and LSD Tool are trademarks of LOYTEC electronics GmbH LonTalk LonWorks and Neuron LonMaker and LNS are trademarks of Echelon Corporation registered in the United States and other countries Version 2 2 LOYTEC electronics GmbH LSD Tool User Manual 4 Contents IEP Se se e o A A un Be a ie che seta dae eA ee ha 5 RE ONCE TTT 5 12 SCOPE Add 5 2 Jnstaline th LSD E Ke TTT 6 3 Starting the LSD H RTT 7 c Usine the LSD Tool israr O C Pe a E 9 4 amp 1 The ESD Tool Main WOW A eee dex 9 42 Tree View TAM SNS NS nn Ged tos ME Ame es NC Nan ce ee 9 4 2 1 Adding and Deleting Node
3. and is kept over a reset of the device Wink sends a wink message to the node so that the node executes it s wink action Lock allows setting a password on a node If the password is set the configuration cannot be changed via the network Nodes that are locked via a password show a key icon besides the state icon in the tree view Unlock allows unlocking the device Unlocking the device removes the key icon from the node in the tree view Reset to Factory Settings allows resetting the node to its factory settings On the L IP node the IP settings of the node are not reset so that the node can still be reached over an IP channel after executing the reset to factory command Version 2 2 LOYTEC electronics GmbH LSD Tool User Manual 11 4 3 Device Info Frame When a device is selected the information of the device is shown on different tabs in the device info frame Whenever a device is added to the internal database the LSD Tool reads from the device which information and configuration options are available and displays the corresponding tabs in the Device Info Frame The following section gives a short overview about what information tabs are available A detailed description of the different items on the tab sheets can be found in the online help of the LSD Tool When a tab is selected in the Device Info Frame the LSD Tool checks if the information for this tab is already present in the database If the information
4. edure for the LSD Tool The program is now ready to be used Version 2 2 LOYTEC electronics GmbH LSD Tool User Manual 7 3 Starting the LSD Tool The LSD Tool is started by selecting the corresponding entry from the Windows start menu After the first startup the LSD Tool displays the window shown in Figure 1 LSD Tool LOYTEC System Diagnostic Tool EXPERT MODE 3 lol xj File View Node Network Help safaj i ials 4 Gerec 1u Switch 0 LP 0 E Leroy 0 Network Interface Y L Core 0 Fallback Node 0 Confi guration No Node selected LSD Tool Status belected Interface None Selected Node None Figure 1 LSD Tool main window The status bar shows that the tool is currently OFFNET it has no connection to the network and no network interface is selected To access nodes on the network the network interface of the LSD Tool has to be configured This is done by opening the network interface configuration dialog via the File menu or by clicking the corresponding button al in the speed bar This opens the dialog shown in Figure 2 Version 2 2 LOYTEC electronics GmbH LSD Tool User Manual 8 Network Interface Configuration xj Network Interface Selection Sr Network Interf NIC_PCI_2 y dc Network Interface Transceiver XF 1250 Select Selection T Expert Mode Local Interface Address Configuration Domain ID pa m Domain Length LH IOT LH LH Subnet
5. etup Life List Temperature CRC Errors Bandwidth Utilization Missed Preambles Configuration Temperature History Enable J Maximum Temperature C ya Poll Interval sec 60 gt E Minimum Temperature C Na Alarm Limit C 50 Logfile 5 Reset Values Status OK Reset Alarm Temperature Histroy 60 C oc 04 00 00 Os Figure 4 Device Monitoring Tab All monitoring options allow adjusting the poll interval which controls how often the monitored value should be requested from the node Optionally a log file in which the status information of the node is stored can be specified The monitored data is stored in a text file together with a time stamp The different entries for a set of data time stamp value are separated by the separation character which can be adjusted in the File gt Configuration menu By default a semicolon is used so that the log can be imported into spreadsheet programs like Microsoft Excel CSV format For all devices there is the option to monitor the life state of a node The LSD Tool frequently pings the node and writes an error message into the Status View Frame if the node does not respond Depending on the device type the following parameters can be monitored Channel bandwidth utilization CRC Errors per second Missed preambles per second Device temperature The polled values are displayed in a graphical trend window For the parameters which are calculated for eac
6. fi Node 122 Get Domain from Network Interface Domain Configuration Figure 2 Network Interface Configuration Dialog Select the network interface which connects to the network and for which the LSD Tool is registered To communicate with devices which have a configured domain table devices that have been commissioned with a network management tool like LonMaker like L IP devices in router mode or L Proxy devices the LSD Tool has to reside in the same domain and subnet as the device itself The network address of the LSD Tool can be configured in the lower section of the Network Interface Selection dialog If the network domain is unknown the button Get Domain from Network can be pressed This connects the LSD Tool to the network and lets the LSD Tool wait for a service pin message of a node on the network Now press a service pin of a node which is commissioned in the network and which resides on the network channel to which the LSD Tool is connected When a service pin message is received the LSD Tool reads the domain table of the node and enters the domain and subnet information into the Network Interface Configuration dialog Mind that only valid domain table entries can be used L Switch and L IP devices in switching mode have no valid domain configuration set and therefore can not be used to configure the working domain for the LSD Tool Enter a Node number that is not in use and press the OK but
7. gured subnet node address in the network domain but the channel id which is used to help the LNS recover process to match discovered devices with the discovered network channels is not properly configured Therefore the LNS recover process might terminate if it finds the LSD Tool The LSD Tool can be restarted after the recovery process Version 2 2 LOYTEC electronics GmbH LSD Tool User Manual 15 5 Trouble Shooting 5 1 License not valid When pressing the OK Button in the Network Interface Configuration dialog the following message appears GER x LSD Tool is not registered for the selected hardware please register with LConfig Figure 5 License error message When the OK button is pressed the LSD Tool closes immediately This error can be caused because no valid license registration code for the selected network interface was found If multiple LOYTEC network interface cards are present on the machine a wrong interface may have been selected or the registration code was not correctly entered in the L Config tool 5 2 Empty Interface Selection Dialog The interface selection dialog shows no interface in the drop down box What can be the reason for this The LSD Tool could not find LOYTEC network interfaces on the PC Please check if the network interface drivers are installed properly and the L Config tool was properly executed For NIC 852 CNIP interfaces please check if the USB dongle is plugged into the USB
8. h port separately e g CRC Errors Channel Bandwidth Missed Preambles the values are plotted in different colors for each channel Checkboxes allow to enable or disable the graph for each individual port The slider on the left side of the trend log allows to change the scaling for the y axis of the trend log It is also possible to define alarm limits for the different monitored parameters Whenever the monitored value exceeds the alarm limit the node state icon in the Node Tree Frame turns red and an entry is written into the Status Version 2 2 LOYTEC electronics GmbH LSD Tool User Manual 14 Log Frame Each alarm can be cleared by clicking the Reset Alarm button on the corresponding alarm monitoring tab or by selecting Reset All Alarms from the Network menu 4 7 Advanced Topics 4 7 1 Multiple interface configurations The LSD Tool allows storing different sets of configurations A configuration set stores the used interface device together with the address configuration of the interface device and the communication parameters A new configuration can be created by specifying the c config as a parameter on the command line when the LSD Tool is started where config is the name for the requested configuration e g LSDTool exe c config If the configuration is not yet present a new configuration is created and the used values are stored under this configuration in the Windows registry If the configuration is alread
9. llisions 0 Device Info Frame Tree View Frame Status Log Frame lONNET Selected Interface PCI1 NIC709 XF 1250 Selected Node Device 1 Figure 3 LSD Tool Frames 4 2 Tree View Frame The tree in the Tree View Frame shows all devices which have been recognized by the LSD Tool and which have been registered in the internal database Within this tree single devices can be selected Whenever a device is selected detailed information about the device is shown in the Main Info Frame on the right side of the tree view 4 2 1 Adding and Deleting Nodes in the Tree View Nodes can be added to the tree view in three different ways Version 2 2 LOYTEC electronics GmbH LSD Tool User Manual 10 Press the service pin of a node When the LSD Tool receives the service pin message it checks the internal data base if the node is already registered It checks if the program ID belongs to a supported device and adds the node to the internal database Manually adding a node This can be done by selecting the Add node menu item from the Network menu by pressing Ctrl A or by selecting the button from the speed bar A dialog which requests the Node ID of the new device appears Optionally also a name for the node can be entered When the dialog is closed OK button the LSD Tool performs the device check as previously described and adds the node to the internal database Scanning the network A network scan ca
10. n be triggered by selecting the Scan entry from the Network menu by pressing F3 or by selecting the 4 button from the speed bar A dialog opens which allows selecting the device types that should be scanned on the network During the network scan the LSD Tool searches for all selected device in the domain in which the LSD Tool is currently configured Whenever a device is added to the internal database the device is also added to the device tree in the Tree View Frame For easy identification of different devices the label of the device in the tree view can be edited The icon besides the device name shows the state of the device If the button is blue the device is in normal operation and no monitoring is in progress If the button is green the device is monitored and all monitored parameters are outside the warning level If the button is red the device is monitored and has exceeded one ore more error levels or the device could not be contacted The device state icon stays red until the alarm is cleared See Section 4 6 for more details about monitoring of devices A right click on a device opens a context menu The context menu allows executing the following actions on the node Delete remove the device from the internal database and from the tree view Reset performs a hard reset of the node Set Location ID allows setting a location ID inside the device The location ID is stored in the non volatile memory of the device
11. of the LSD Tool displays status and error log information This frame can be hidden via the View menu in the main menu bar The log can be saved to a file by right clicking on the frame and choosing the Save option 4 5 Loading and Saving a Project The whole project can be saved to a file and loaded later This feature can be used to store all statistics information for a later detailed review To store the project select the Save option from the File menu or press on the Save symbol in the speed bar After the destination file name is selected the LSD Tool opens a request box which asks if all information should be downloaded from all nodes If this option is selected the LSD Tool reads all statistics and configuration information except the subnet node forwarding tables from all nodes and writes it into the file If the option is not selected the LSD Tool only writes the current contents of the internal database into the file Information which has not yet been retrieved from the nodes is not saved 4 6 Monitoring Nodes and Alarms Depending of the node type different parameters of a node can be monitored with the LSD Tool The monitoring options are accessible via the Monitoring tab in the Main Info Frame shown in Figure 4 Version 2 2 LOYTEC electronics GmbH LSD Tool User Manual 13 General Node Info Drion Node Info Firmware Info Monitoring Switch Tables Switch Statistics Channel Statistics L Switch S
12. port of the PC 5 3 Network scan doesn t report all devices The LSD Tool could not find a node on the network or not all nodes were found If the LSD Tool is not configured in the same domain like the devices it cannot find the devices on the network when it performs a network scan To find all nodes on the network the correct domain and subnet must be adjusted in the network interface configuration dialog Another option is to add the missing devices manually or to press the service pin on the missing devices so that the device is added to the LSD Tool database For devices which have multiple network ports connected to the network like L Proxy nodes the LSD Tool registers the device in the internal database only once This means that also for these nodes there is only one entry in the device tree Version 2 2 LOYTEC electronics GmbH LSD Tool User Manual 16 6 Version History Date Version Author Description 02 06 03 2 0 NR Initial revision V2 0 2 1 NR Updates for V2 1 02 24 04 2 2 NR Increased version info to V2 2 Version 2 2 LOYTEC electronics GmbH LSD Tool User Manual 17 7 References 1 NIC User Manual Version 2 1 June 2003 Version 2 2 LOYTEC electronics GmbH
13. products monitor different statistics parameters and the presence of a node and store the information to a file configure the LOYTEC network interface products over any LonWorks channel including IP connections using the EIA 852 channel 1 2 Scope This document covers the LSD Tool software starting with version 2 2 Version 2 2 LOYTEC electronics GmbH LSD Tool User Manual 6 2 Installing the LSD Tool Before the LSD Tool is installed the NIC 709 or NIC 852 software has to be installed on the PC The NIC 709 NIC 852 software package contains the drivers for your LOYTEC network interface card and the L Config tool which allows setting up the LOYTEC network interface and entering the registration code for the LSD Tool For further information about the NIC 709 or NIC 852 software package refer to the NIC User Manual 1 Please uninstall all previous versions of the LSD Tool from your PC The LSD Tool comes with a self extracting setup package Start the setup program and follow the instructions during the setup process When the setup program asks for the serial number enter the LSD Tool serial number printed on the LSD Tool software package or the LOYTEC product CD After the setup process has completed start the L Config Tool and enter the registration code for the LSD Tool software Please refer to the NIC Users Manual 1 for further information about how to enter a registration code This finishes the installation proc
14. s in the Tree View 9 4 3 Device Info Prame a eee ek 11 4 3 1 Information and Configuration Tabs sss sss sese 11 gA Status Log FTAM S acs tet SU as Oh Sa e as 12 4 5 Loading and Saving a Project inner ati net Edit nue 12 4 6 Monitoring Nodes and Alanis sss sss sss 12 4I Advanced TOPICS TTT 14 4 7 1 Multiple interface configurations essere 14 e T 2 A a Ne 14 2 Tro ble Shooting iodo 15 Sk id cercen A E ae S a A ct aca 15 5 2 Empty Interface Selection Dialog ess se er ee 15 5 3 Network scan doesn t report all devices sss 15 O Version HIStory A A a ange Hee a a ee 16 T References aeee SO On ic cee ds Sean ed ued aah a EE E E a 17 Version 2 2 LOYTEC electronics GmbH LSD Tool User Manual 5 1 Introduction 1 1 Overview The LOYTEC System Diagnostics Tool LSD Tool is an easy to use Windows software which allows remote access and adjustment of the configuration parameters and statistics information of all LOYTEC network infrastructure products ORION Stack based nodes and generic nodes It enables the user to find problems in a network or in single network segment without having physical access to the network segments The LSD Tool runs on all LOYTEC network interface cards including the NIC 852 which even allows to execute all operations over an IP connection The LSD Tool can be used to find problems in single network segment by investigating the statistics information which 1s stored in the LOYTEC network interface
15. ton to configure the domain table of the network interface and to put the LSD Tool in ONNET node For future use of the LSD Tool the network interface configuration is stored in the Windows registry The LSD Tool shows the selected network interface after the program start in the status bar Select Go Onnet from the File menu or press the corresponding button ES in the speed bar to set the LSD Tool ONNET Version 2 2 LOYTEC electronics GmbH LSD Tool User Manual 9 4 Using the LSD Tool 4 1 The LSD Tool Main Window The LSD Tool main window is divided into three sections the Tree View Frame on the left side of the window the Device Info Frame which covers the main part of the window and the Status Log Frame on the bottom of the window I LSD Tool LOYTEC System Diagnostic Tool E 18 xj File View Node Network Help FA dee da A leone General Node Info Orion Node Info Firmware Info Monitoring Switch Tables Switch Statistics Channel Statistics L Switch Setup B L Switch D Device 1 Node Statistic y e BHP O Node Device 1 ed Data Pott Trow Pots pora Pots ar ge oye Node ID 80 00 00 00FF CA Transmission Enors 0 0 0 0 beck Hace Transmit Tx Failures 0 Program ID S0 00 A9 01 00 01 03 98 Receive TX Full 0 Lost Messages 0 7 Missed Messages 0 Logaton Layer 2 Received 649 Layer 3 Received 649 Layer 3 Transmitted 493 Transmit TX Reties 0 Backlog Overflows 0 Late Acknowledgements 0 Co
16. was not yet retrieved from the node the LSD Tool reads the information from the node writes it into the database and K displays the information When the refresh button is pressed F5 the information is re read from the node and the database and the display are updated 4 3 1 Information and Configuration Tabs General Node Info This tab is available on every node It contains information about the node ID of the connected port the name of the node the program ID the location ID and the general node error counters for all ports of the device Orion Node Info This tab shows the version of the ORION Stack in the node the number of network ports number or the currently connected port the serial number the uptime of the device since the last reset the node IDs of all ports the error log of the node and the Orion Statistics for all ports Firmware Info This tab shows the current firmware image and allows downloading a new firmware image into the node Before the image is downloaded the LSD Tool tries to check if the firmware image belongs to the selected device If the device does not provide the required information a warning dialog appears and the user has to confirm the firmware download If the firmware does not belong to the device the LSD Tool refuses to download the firmware Monitoring This tab allows monitoring the life state the CRC error counters the missed preamble counters and the bandwidth utilization
17. y present the stored configuration parameters are used 4 7 2 Segmentation Ratios The switch statistics tab in the Main Info Frame calculates two parameters which can be used as an indicator for the quality of the network segmentation Network Segmentation Ratio The network segmentation ratio indicates how many packets of all processed packets where kept on the same port of the switching device A ratio of 100 indicates that all packets are kept on the same port and that no packets are forwarded 0 indicates that all received packets are forwarded to one or more destination ports Port Forwarding Factor The port forwarding factor is the average value to how many ports a received packet is forwarded A value of 0 would mean that the packet is not forwarded to any port Network Segmentation Ratio of 100 a value of 1 indicates that a packet is forwarded to exactly one port like a learned subnet node address of the L Switch A value gt 1 indicates broadcast addressing or group addressed messages where the group members are spread over multiple ports Please keep in mind that the Port Forwarding Factor is influenced by the number of available ports on the device A 5 Port L Switch can have a Port Forwarding Factor between 0 and 4 whereas a 2 Port L IP can have values between 0 and 1 4 7 3 Recovering an LNS Database The LSD Tool must be closed when a LNS network recovery process is started This is because the LSD Tool has a confi