1. Auto run mode To activate the unit in auto run mode press the MODE button to show AUTO RUN on the LCD screen Now press the ENTER button to select the desired frequency level by using the UP and DOWN buttons FQN 01 99 01 low 99 high Note In this mode it will run 13 built in programmes in a continious loop Slave mode To activate the unit in slave mode first you must link multiple units together and press the MODE button to show SLAVE MODE on the LCD screen Now on the master unit press the MODE button to select the desired mode and the slave units will now run in sequence with the master unit Built in programmes To activate the units built in programmes press the MODE button to show 01 DIMMING on the LCD screen Press the ENTER button to choose between the 14 built in programmes by using the UP and DOWN buttons Now press the ENTER button to select the desired speed and adjust by using the UP and DOWN buttons Press the ENTER button once more to select the desired flash value and adjust by using the UP and DOWN buttons Speed values 00 99 00 slow 99 fast Flash values 00 99 00 slow 99 fast For the 14 built in programmes please see page 5 DMX mode To activate the unit in DMX mode press the MODE button to show DMX MODE on the LCD screen Press the ENTER button and select the desir
2. WWW PROLIGHT CO UK ARCHI BAR 48 Order code LEDJ222 USER MANUAL ARCHI BAR 48 SAFETY WARNING FOR YOUR OWN SAFETY PLEASE READ THIS USER MANUAL CAREFULLY BEFORE YOUR INITIAL START UP SAFETY INSTRUCTIONS Every person involved with the installation operation amp maintenance of this equipment should Be competent Follow the instructions of this manual CAUTION TAKE CARE USING THIS EQUIPMENT HIGH VOLTAGE RISK OF ELECTRIC SHOCK Before your initial start up please make sure that there is no damage caused during transportation Should there be any consult your dealer and do not use the equipment To maintain the equipment in good working condition and to ensure safe operation it is necessary for the user to follow the safety instructions and warning notes written in this manual Please note that damages caused by user modifications to this equipment are not subject to warranty ARCHI BAR 48 SAFETY IMPORTANT The manufacturer will not accept liability for any resulting damages caused by the non observance of this manual or any unauthorised modification to the equipment Never let the power cable come into contact with other cables Handle the power cable and all mains voltage connections with particular caution Never remove warning or informative labels from the equipment Do not open the equipment and do not modify the equipment Do not connect this equipment to a dimmer pack
3. Do not switch the equipment on and off in short intervals as this will reduce the system s life Do not expose to flammable sources liquids or gases Always disconnect the power from the mains when equipment is not in use or before cleaning Only handle the power cable by the plug Never pull out the plug by pulling the power cable Make sure that the available voltage is between 220v 240v Make sure that the power cable is never crimped or damaged Check the equipment and the power cable periodically e If the equipment is dropped or damaged disconnect the mains power supply immediately Have a qualified engineer inspect the equipment before operating again If your product fails to function correctly discontinue use immediately Pack the unit securely preferably in the original packing material and return it to your Prolight dealer for service Only use fuses of same type and rating Repairs servicing and power connection must only be carried out by a qualified technician THIS UNIT CONTAINS NO USER SERVICEABLE PARTS WARRANTY One year from date of purchase OPERATING DETERMINATIONS If this equipment is operated in any other way than those described in this manual the product may suffer damage and the warranty becomes void Incorrect operation may lead to danger e g short circuit burns electric shocks lamp failure etc Do not endanger your own safety and the safety of others Incorrect installation o
4. e used The chart below details the correct cable conversion 5 Pin XLR socket Pin 1 SO Sireen A 3 Pin XLR socket H a Pin 1 GND screen Pin 2 Signal Pin 3 Signal H R 5 Pin XLR socket 3 Pin XLR socket G Pin 1 GND screen Pin 1 GND scteen Pin 2 Signal Pin 2 Signal Pin 3 Signal Pin 3 Signal in 4 Pin 5 NIC ARCHI BAR 48 TECHNICAL SPECIFICATIONS Technical Specifications Weight amp Dimensions LSO M E 1000mm s Width TESI 120mm uli nee 175mm iD m 10 2sKgs Power AC MAUR saci osc aia craic ere ch es aisle stent ele Radar E 240V 50hz e Power consumption wwwrnnans 84W e Fuse Ur mee D m F2A Control amp Programming DAA input c Locking 3 pin XLR male socket Data OUtGUt MM Locking 3 pin XLR female socket PROTO ON tM EM I DMX 512 USITT e DMX channel 19 6 and 4 10 CREATE THE RIGHT EFFECT www prolight co uk
5. ed DMX address setting by using the UP and DOWN buttons Then to select one of the 3 DMX modes 19 6 or 4 channel press the ENTER button again to choose the desired DMX mode by using the UP and DOWN buttons For the 4 6 and 19 channel DMX address information please see pages 6 amp 7 NOTE Once the desired settings have been selected in each of the above modes ALWAYS confirm the settings by pressing the ENTER button 4 ARCHI BAR 48 BUILT IN PROGRAMME CHART 14 Built in programme chart 01 Dimming Blackout Full on Red 00 99 Green 00 99 Blue 00 99 White 00 99 Flash 00 99 Flash adjustable 02 Colour Jump 7 colour change Speed 00 99 Flash 00 99 Speed amp Flash adjustable 03 Colour Fade 7 colour fade in fade out Speed 00 99 Flash 00 99 Speed amp Flash adjustable 04 Dream 7 colour fade Speed 00 99 Flash 00 99 Speed amp Flash adjustable 05 Colour Flow 7 colour chase forward amp reverse Speed 00 99 Flash 00 99 Speed amp Flash adjustable 06 Over Flow 7 colour chase in relay pattern forward amp reverse Speed 00 99 Flash 00 99 Speed amp Flash adjustable 07 Colour Chase 7 colour chase forward Speed 00 99 Flash 00 99 Speed amp Flash adjustable 08 Multi colour Multi colour relay chase Speed 00 99 Flash 00 99 Speed amp Flash adjustable 09 Fade Flow 7 colour fade relay chase Speed 00 99 Flash 00 99 Speed amp Flas
6. h adjustable 10 Two Flow 2 colour relay chase Speed 00 99 Flash 00 99 Speed amp Flash adjustable 11 One Way 7 colour relay chase Speed 00 99 Flash 00 99 Speed amp Flash adjustable 12 Two Way 7 colour relay chase criss cross Speed 00 99 Flash 00 99 Speed amp Flash adjustable 13 Two colour 7 multi colour relay chase criss cross Speed 00 99 Flash 00 99 Speed amp Flash adjustable 4 channel mode DMX chart 6 channel mode DMX chart Master 0 10 On W Dimmer 11 255 Flash 0 255 0 255 0 255 0 255 0 T 0 gt 0 ae 0 pn 0 255 ARCHI BAR 48 DMX PROGRAMME CHARTS 19 channel mode DMX chart CH10 CH11 CH12 CH13 CH14 CH15 M out dimmer 0 255 0 255 0 255 0 255 11 15 16 20 21 25 Green 26 30 ue 31 35 E pp po 36 40 41 45 0 255 0 255 GIB are o W B 61 65 W G R G B 71 75 W 76 80 R B W 81 85 G B W SE L i R G B W a gt 29 20 0 Qi o an a 2 67 Q o o c 5 gt o 91 100 R G B W 101 110 Colour jump 111 120 Dream 121 130 131 140 Over Lap flow 141 150 Colour chase Speed Flash T51 In 0 255 0 255 161 170 Fade flow 171 180 Two flow 181 190 One way 191 200 Two way 201 210 Two colour 211 255 N A ons cme en ene omo 11 15 Dimmer Flash R4 G4 B4 W4 dimmer 0 255 0 255 0 255 0 255 0 255 0 255 amp s o c 5 ARCHI BAR 48 DMX SET UP DMX 512 DMX Digital Multiplex i
7. ppliers or Prolight dealers Please quote CABL 10 2M CABL11 5M CABL 12 10M Also remember that DMX cable must be daisy chained and cannot be split ARCHI BAR 48 DMX SET UP Notice Be sure to follow figures 2 amp 3 when making your own cables Do not connect the cable s shield conductor to the ground lug or allow the shield conductor to come in contact with the XLR s outer casing Grounding the shield could cause a short circuit and erratic behaviour common DMX 512 in 3 pin XLR DMX 512 out 3 pin XLR XLR MALE SOCKET XLR FEMALE SOCKET XLR Pin Configuration 2 cold 1 ground 1 ground 2 cold Pin 1 2 Ground Q Pin 2 Negative 3Hot 3 Hot Pin 3 Postive FIGURE 3 FIGURE 2 Special Note Line termination When longer runs of cable are used you may need to use a terminator on the last unit to avoid erratic behaviour Termination reduces signal transmission problems O and interferance it is always advisable to connect a O DMX terminal resistance 120 Ohm 1 4 W between pin 2 DMX and pin 3 DMX of the last fixture Using a cable terminator part number CABL90 will decrease the possibilities of erratic behaviour 5 Pin XLR DMX Connectors e Some manufactures use 5 pin XLR connectors for data transmission in place of 3 pin 5 Pin XLR fixtures may be implemented in a 3 pin XLR DMX line When inserting standard 5 pin XLR connectors in to a 3 pin line a cable adaptor must b
8. r use can cause serious damage to people and property ARCHI BAR 48 INTRODUCTION Introduction Features e DMX channels 4 6 19 selectable 48 x 3W Ultra Bright RGBW LEDs R 12 G 12 B 12 W 12 14 built in programmes 4 push button LCD display Master Slave functions Auto run mode Power in out connections DMX in out connections Consumption 84W Beam 25 degrees Power supply 240V Dimensions 1000 x 120 x 175mm Weight 10 2Kgs Overview Qu ted cex LLL em O O www prolight co uk O O O O Setup Operating Instructions The Archi Bar 48 is a DMX 512 controllable unit made up of high efficiency and Ultra Bright RGBW LEDs and will operate in stand alone master slave or DMX control modes ARCHI BAR 48 OPERATION MODES Operation modes Dimming mode To activate the unit in dimming mode press the MODE button to show DIMMING on the LCD screen Now press the ENTER button to set the brightness of the LEDs by using the UP and DOWN buttons Press the ENTER button once for the Red LEDs twice for Green LEDs three for Blue LEDs and four for the White LEDs Each of the colours can be set from 00 99 by using the UP and DOWN buttons Press the ENTER button once more to select the desired flash value and adjust by using the UP and DOWN buttons Brightness levels 00 99 00 low 99 high Flash values 00 99 00 slow 99 fast
9. s a universal protocol used as a form of communication between intelligent fixtures and controllers A DMX controller sends DMX data instructions form the controller to the fixture DMX data is sent as serial data that travels from fixture to fixture via the DATA IN and DATA OUT XLR terminals located on all DMX fixtures most controllers only have a data out terminal DMX Linking e DMX is a language allowing all makes and models of different manufactures to be linked together and operate from a single controller as long as all fixtures and the controller are DMX compliant To ensure proper DMX data transmission when using several DMX fixtures try to use the shortest cable path possible The order in which fixtures are connected in a DMX line does not influence the DMX addressing For example a fixture assigned to a DMX address of 1 may be placed anywhere in a DMX line at the beginning at the end or anywhere in the middle When a fixture is assigned a DMX address of 1 the DMX controller knows to send DATA assigned to address 1 to that unit no matter where it is located in the DMX chain DATA Cable DMX cable requirements for DMX operation The Archi Bar 48 can be controlled via DMX 512 protocol The DMX address is set on the back of the unit Your unit and your DMX controller require a standard 3 pin XLR connector for data input output figure 1 Figure 1 Further DMX cables can be purchased from all good sound and lighting su