Home
USER MANUAL
Contents
1. XLR MALE SOCKET XLR FEMALE SOCKET XLR Pin Configuration 2 cold 1 ground 1 ground gt cold Pin 1 2 Ground 2 Negative 3Hot 3Hot Pin 3 Postive FIGURE 3 FIGURE 2 Special Note Line termination When longer runs of cable are used you may need to use a terminator on the last unit to avoid erratic behaviour Termination reduces signal transmission problems and interferance it is always advisable to connect a DMX terminal resistance 120 Ohm 1 4 W between pin 2 DMX and pin 3 DMX of the last fixture Using a cable terminator part number CABL90 will decrease the possibilities of erratic behaviour 5 Pin XLR DMX Connectors e Some manufactures use 5 pin XLR connectors for data transmission in place of 3 pin 5 Pin XLR fixtures may be implemented in a 3 pin XLR DMX line When inserting standard 5 pin XLR connectors in to a 3 pin line a cable adaptor must be used The Chart below details the correct cable conversion Bin WGN Coo e 3 Pin XLR socket Pin 2 Signal Pin 1 GND Valea Pin 3 Signal A A Pin 2 Signal Pin 4 N lt 3 Signal Pin 5 N C 5 Pin XLR socket 3 Pin XLR socket 1 GND screen Pin 1 GND reen Pin 2 Signal Pin 2 Sign Pin 3 SIL in Pin 3 Signal e Pin 4 Pin 5 N C LEDJ Tri LED Matrix Table Cloth Dip Switch Reference Chart DMX Dip Switch Quick Reference Chart Dip Switch Position we
2. To ensure proper DMX data transmission when using several DMX fixtures try to use the shortest cable path possible The order in which fixtures are connected in a DMX line does not influence the DMX addressing For example a fixture assigned to a DMX address of 1 may be placed anywhere in a DMX line at the beginning at the end or anywhere in the middle When a fixture is assigned a DMX address of 1 the DMX controller knows to send DATA assigned to address 1 to that unit no matter where it is located in the DMX chain DATA Cable DMX cable requirements for DMX operation e The LEDJ Tri LED Matrix Table Cloth can be controlled via DMX 512 protocol The DMX address is set on the back of the unit Your unit and your DMX controller require a standard 3 pin XLR connector for data input output figure 1 Figure 1 Further DMX cables can be purchased from all good sound and lighting suppliers or Prolight dealers Please quote CABL10 2M CABL11 5M CABL12 10M Also remember that DMX cable must be daisy chained and cannot be split LEDJ Tri Matrix Table Cloth DMX Set Up Notice Be sure to follow figures 2 amp 3 when making your own cables Do not connect the cable s shield conductor to the ground lug or allow the shield conductor to come in contact with the XLR s outer casing Grounding the shield could cause a short circuit and erratic behaviour common DMX 512 out DMX 512 in 3 pin XLR 3 pin XLR ee
3. www prolight co uk Tri LED Matrix Table Cloth STAR18 USER MANUAL LEDJ Tri Matrix Table Cloth WARNING FOR YOUR OWN SAFETY PLEASE READ THIS USER MANUAL CAREFULLY BEFORE YOUR INITIAL START UP CAUTION Keep this equipment away from rain moisture and liquids SAFETY INSTRUCTIONS Every person involved with the installation operation amp maintenance of this equipment should Be competent Follow the instructions of this manual CAUTION TAKE CARE USING THIS EQUIPMENT HIGH VOLTAGE RISK OF ELECTRIC SHOCK Before your initial start up please make sure that there is no damage caused during transportation Should there be any consult your dealer and do not use the equipment To maintain the equipment in good working condition and to ensure safe operation it is necessary for the user to follow the safety instructions and warning notes written in this manual Please note that damages caused by user modifications to this equipment are not subject to warranty LEDJ Tri Matrix Table Cloth IMPORTANT The manufacturer will not accept liability for any resulting damages caused by the non observance of this manual or any unauthorised modification to the equipment Never let the power cable come into contact with other cables Handle the power cable and all mains voltage connections with particular caution Never remove warning or informative labels from the equipment Do
4. Table Cloth DMX Set Up DMX Control Mode Operating in a DMX control mode environment gives the user the greatest flexibility when it comes to customising or creating a show In this mode you will be able to control each individual trait of the fixture and each fixture independently Setting the DMX address The DMX mode enables the use of a universal DMX controller Each fixture requires a start address from 1 511 A fixture requiring one or more channels for control begins to read the data on the channel indicated by the start address For example a fixture that occupies or uses 7 channels of DMX and was addressed to start on DMX channel 100 would read data from channels 100 101 102 103 104 105 and 106 Choose a start address so that the channels used do not overlap E g the next unit in the chain starts at 107 DMX 512 e DMX Digital Multiplex is a universal protocol used as a form of communication between intelligent fixtures and controllers A DMX controller sends DMX data instructions form the controller to the fixture DMX data is sent as serial data that travels from fixture to fixture via the DATA IN and DATA OUT XLR terminals located on all DMX fixtures most controllers only have a data out terminal DMX Linking e DMX is a language allowing all makes and models of different manufactures to be linked together and operate from a single controller as long as all fixtures and the controller are DMX compliant
5. e WARRANTY One year from date of purchase OPERATING DETERMINATIONS If this equipment is operated in any other way than those described in this manual the product may suffer damage and the warranty becomes void Incorrect operation may lead to danger e g short circuit burns electric shocks lamp failure etc Do not endanger your own safety and the safety of others Incorrect installation or use can cause serious damage to people and property LEDJ Tri LED Matrix Table Cloth Technical Specifications You should find inside the carton the following items 1 Tri LED Matrix Table Cloth 2 Instruction manual 3 Controller 4 SD card Technical Specifications DMX channels 2 DMX sound active and auto run modes 72 Ultra Bright Tri colour LEDs Hanging tabs on 3 sides Fire retardent material Power consumption 25W Power supply 240V Dimensions 2 2 x 1M Weight 4Kgs Overview DIPSWITCHES CC x WWW PROLIGHT CO UK LC gs gt gt QC 000 DMX IN DMX OUT SIGNAL DC OUT SENS POWER SUPPLY z le a Tri LED Matrix Table Cloth OFF LEDJ Tri LED Matrix Table Cloth Operations Operations There are three operating modes to choose from 1 Auto run 2 Sound Active 3 DMX NOTE Before use please insert the supplied SD card and follow the instructions below Auto run mode To set the Matrix table cloth in auto run mode set all dip switches to the off position and use the SENSITIVITY SPEED con
6. not open the equipment and do not modify the equipment Do not connect this equipment to a dimmer pack Do not switch the equipment on and off in short intervals as this will reduce the system s life Only use the equipment indoors Do not expose to flammable sources liquids or gases Always disconnect the power from the mains when equipment is not in use or before cleaning Only handle the power cable by the plug Never pull out the plug by pulling the power cable Make sure that the available voltage is between 220v 240v Make sure that the power cable is never crimped or damaged Check the equipment and the power cable periodically f the equipment is dropped or damaged disconnect the mains power supply immediately Have a qualified engineer inspect the equipment before operating again f the equipment has been exposed to drastic temperature fluctuation e g after transportation do not switch it on immediately The arising condensation might damage the equipment Leave the equipment switched off until it has reached room temperature If your product fails to function correctly discontinue use immediately Pack the unit securely preferably in the original packing material and return it to your Prolight dealer for service Only use fuses of same type and rating Repairs servicing and power connection must only be carried out by a qualified technician THIS UNIT CONTAINS NO USER SERVICEABLE PARTS
7. sers ze T s Teen rar 08 ss asa ver 5 3 26 uer T 130 162 Tor 258 200 22 350 S98 8 3 s er ss 151 EJ EEE 3S8 300 132 16 vos 228 280 262 324368 sas 200 052051 S 102 154 EEE 228 30 22 ase 005 LT 39 Ti e ss zs 283 zs ar Fg 49 72 o4 136 166 200 232 294 296 28 360 202 424 456 486 S 4i 75 frar veo z 265 257 328 ei ses 05 457 485 106 138 370 02 4 286 T 200 330 362 394 425 75 Tor vas 7070 3505 07 00 07 104878 T2 74 206 28 270 302 394 366 398 430 62 297 rn 30 Ti 476208240 272 a6 368 400 432 f aa 6 v E 241 275 at eo aor ss KA Fir en e2 4 EE 274 306 585 36 402 5405 05 E ES A E EEE a f a72 EE a re a a ar we tf eT 2 Se ss EE 270 200 sra s 05827 ras ss ar ne sor EA 2er 278 351 ave dor 439 4 5087 k E 5 b gt 4 33 3 8 8 an En 6 CH EO k ls
8. trol to set the desired running speed The Matrix table cloth will now run through all of its in built programmes Sound active mode To set the Matrix table cloth into sound active mode set dip switch 10 to the ON position and all others to the OFF position Now use the SENSITIVITY SPEED control to set the desired sensitivity level DMX mode DMX Control Mode Operating in a DMX control mode environment gives the user the greatest flexibility when it comes to customising or creating a show In this mode you will be able to control each individual trait of the cloth and each cloth independently The Tri LED Matrix Table Cloth uses 2 channels of control Use dip switches 1 9 to address each cloth accordingly Setting the DMX address The DMX mode enables the use of a universal DMX controller Each cloth requires a start address from 1 511 A cloth requiring one or more channels for control begins to read the data on the channel indicated by the start address For example a cloth that occupies or uses 7 channels of DMX and was addressed to start on DMX channel 100 would read data from channels 100 101 102 103 104 105 and 106 Choose a start address so that the channels used do not overlap E g the next unit in the chain starts at 107 DMX chart Value Function Notes 0 9 Blackout 10 239 Pattern selector 240255 Autorun 09090900 0 9 Blackout Speed slow to fas LEDJ Tri LED Matrix