1. Note that in some menus the boxes in the 4 line also give the current status of that function and that in some menus more information is provided and hence the exact layout above not followed The approach is the same and where there are differences instructions provided F4 usually marked Exit returns to the previous level in the menu and in many screens accepts the conditions set in that menu If Marked Quit then that screen data is discarded before return Repeatedly pressing F4 will bring you back to the main menu Version 1 0 Issue 3 07 July 2014 Page 13 of 36 Interleader Ltd 2014 FEC Remote Lighting Controller HP0656 User Installation and Operation Manual 5 2 The Main Screen The top menu is not really a menu at all but rather the main status display page with two States 1 Link un tested and 2 Link tested By default the screen remains lit all of the time To save power particularly useful in battery powered installations the LCD screen back light can be set to Auto in which case it goes out 30 seconds after the last key was pressed or the screen was refreshed To re activate the backlight simply momentarily touch any key and the screen will light up for another 30 seconds During an Active Period when the controller has been commanded to turn on the lights the screen remains on See section on system setup The screen provides all of the essential information to show the status of the system
2. Helirad Light LU Helirfad Light 5 Statue Inacti Status fa Ee AE Link Untested fer Bh Pee eS Men Test Link 1st D D D D D tatus The screen on the left is showing that the link is untested the screen to the right that it has been tested and the lights are inactive off 5 2 1 Entering Menu Mode To enter the Menu mode simply press the function key F4 You will be taken immediately to the PIN challenge screen over before making menu selections Note that the representation above is used consistently throughout the manual In this paper all live options are shown Solid inactive buttons screens greyed out Keypad entryis shown Ges Warning Once the Menu Mode is selected the system no longer monitors the GSM receiver and will not respond to remote commands All setups should be performed when it is known that no movements requiring the monitoring of the lighting controller are required Version 1 0 Issue 3 07 July 2014 Page 14 of 36 Interleader Ltd 2014 FEC Remote Lighting Controller HP0656 User Installation and Operation Manual 6 Access Menu Pressing Menu on the main menu first brings up a PIN challenge menu to determine which type of user is accessing the system since each can perform different functions There are four types of User defined in the system 1 Staff A person granted permission to perform certain commands 2 Ops The Owner Operator of the faci
3. Off Setur TxRx Exit o o o Setur DR Unit Setur Fead GSM Unit Send Receive Test Press soft keys for Fress soft keys for Press soft keys for On Setur TEx Exit Clock Hos Tech Exit Send Fecy CID Exit LI O O am B O O O B 8 o O Note that the 1 soft key is solid indicating that the GSM receiver is ON and that the soft key option is to turn it off Pressing F1 will toggle the GSM receiver on and off and it will be left in that state on Exit The other menu options are Setup Performs a variety of configuration options on the GSM system and TxRx Enables a number of GSM SMS tests to be performed Version 1 0 Issue 3 07 July 2014 Page 18 of 36 Interleader Ltd 2014 FEC Remote Lighting Controller HP0656 User Installation and Operation Manual 6 3 1 Setup GSM selecting Setup brings up the following menu which allows 1 The clock calendar to be set 2 The Operator Agency and Helipad RLC Pad stored numbers to be viewed and changed and 3 The GSM module to be interrogated for version build information and the current received signal strength Rssi to be read A Level 5 GSM Setting Menu Setur Read GSM Unit F1 Sets the Clock Calendar eee ott keus tori Taf F2 Enables Operator Agency and Helipad o o o sM numbers to be edited F3 Shows GSM module parameters The Received Signal Strength Indicator Rssi Shows GSM signal Strength Set Phone Hupaberz TEES Osi r rr P
4. Version 1 0 Issue 3 07 July 2014 Page 7 of 36 Interleader Ltd 2014 FEC Remote Lighting Controller HP0656 User Installation and Operation Manual 4 Installation Installation of the FEC RLC Remote Panel must be carried out by a suitably qualified electrician with full authority to undertake work in the safety critical environment lt is recommended that a formal Statement of Works Standard Operating Procedure or similar is created and used for the initial installation and testing and all subsequent test and maintenance activities to ensure the safety of the installation and personnel 4 1 Locating the Remote Panel The Remote Panel should be located in a secure location that is easy for operational staff to access the keypad and screen and appropriate for the mains wiring The enclosure is intended for wall mounting and with suitable rails or adaptors can be frame or pole mounted Appendix 1 has a full size template for the mounting holes Although the enclosure is IP65 rated a sheltered location is recommended Keep in mind that the controller will need 1 Mains electricity supply and connection to the circuits to be controlled 2 An external GSM aerial Supplied lt is recommended that a GSM Signal Strength Analyser or mobile cell phone on the same network as that intended for the controller is used to check the signal strength quality in the intended location 4 2 Things you will need Before starting the install
5. F3 Are active until a channel is on F4 Selects Menu Helirad Light Status Helirpad Active 41 88 Bel be C 53 Menu E o o H Level 1 Basic Operation channel s on F1 F3 Inactive F4 Selects Menu lt CAN gt Cancels the Siren lt CLR gt Clears the alert after PIN challenge Helirad Light Status AA e Eat G 2 C 3 Menu E o D o The length of time the lights have been on is shown on the status line The siren may be silenced by pressing the lt CAN gt key No PIN is required and the operation is immediate The screen continues to show that it is active by flashing Helipad Active on line 2 once a second The timer will continue to count up to a maximum of 100 minutes when it will roll over to O and start again Once cancelled the siren can only be re activated by another channel going active To cancel the alert completely press lt CLR gt A PIN is prompted for which must be either a valid Staff or Operator PIN If a valid PIN is entered the alert is cancelled and the screen reverts to that shown top left If no valid PIN is entered the alert with or without siren will resume Version 1 0 Issue 3 07 July 2014 Page 29 of 36 Interleader Ltd 2014 8 Summary Specification Controller modes GSM Bands Network Tariff GSM aerial options Degree of protection LCD and Keypad protection Unit operating temperature system Storage temperature Compliance Operating volt
6. 14 Appendix 4 Aerials and Cables 14 1 Mains Cables Switches and Fuses No external mains cables switches or fuses are supplied with the RLC It is the responsibility of the owner installer to ensure that the installation is carried out in such a manner as to ensure the safety of the installation and that it meets all of the relevant local regulations 14 2 GSM Aerial The RLC is supplied with a GSM aerial which must be attached to the socket on top of the unit Ensure that it is a secure fit but do not over tighten lf a remote location for the GSM aerial is required a suitable coax cable fitted with SMA connectors should be obtained To avoid undue cable losses keep the cable as short as possible max 10m Version 1 0 Issue 3 07 July 2014 Page 34 of 36 Interleader Ltd 2014 15 Appendix 5 Mounting Template The template below is at a scale of 1 1 if this document is printed on A4 paper or US Letter and no scaling options are used e g do NOT use the printing option scale to fit FEC Remote Lighting Controller HP0656 User Installation and Operation Manual End of Document Version 1 0 Issue 3 07 July 2014 Page 36 of 36 Interleader Ltd 2014
7. EATS MING Menu MOU sissisrcusirssrrisernssrisiri Eeri EesrEor ires T ESTEE SEESE EE NEEE UEU EEEE 14 6 ACCOSS En E 15 6 1 Setup Control Men 16 02 EONS EE 17 63 DOU SII A En 18 CSA Re HE N e EE eee 19 Sh ee ie 20 BS ERT ue 21 On CGM FSi MNU EE 22 CA SU UENO EE 23 oA DEUN PIN E 24 642 System 2 E 25 Version 1 0 Issue 3 07 July 2014 Page 2 of 36 Interleader Ltd 2014 FEC Remote Lighting Controller HP0656 User Installation and Operation Manual paS Lak RE 26 CAA POW SY em Orn aO E 27 6 4 5 Setup Unit Operation 28 T e date ege E 29 SB SUMMALY PECE O eee stots cerctondecnctot EE A TOE EE 30 9 Power Supply Unit Gpecfcaton 31 1O A US aa E E EISS 31 Ad DIAGNOSIS ANG FAURA Le E EEE E EE EEE EE EEE EEEE 32 12 Appendix T Software lee ET 33 13 Appendix 3 Factory Default Settings cc eccccccececeeeeeceeeeeseeceeseesesseeesseeeessaeeeseaeeeeas 34 14 Appendix 4 Aerials and CGables 34 14 1 Mains Cables Switches and Fuses 34 142 E MA E E EE EEEE 34 15 ADDENGIX 5 Oe fo lge Run E 35 Version 1 0 Issue 3 07 July 2014 Page 3 of 36 Interleader Ltd 2014 FEC Remote Lighting Controller HP0656 User Installation and Operation Manual Document Revision Sheet Verson issue oae Changes 1 March 2014 Draft Document 7 July 2014 1 Production Version 7 July 2014 Internal optimisation not visible to users Version 1 0 Issue 3 07 July 2014 Page 4 of 36 Interleader Ltd 2014 FEC Remote Lig
8. Setting PINs The Operator can set PINs for Staff themselves and the Mimic panel Note that the Mimic PIN entered into the Remote Panel and the RLC must be the same as each unit is expecting this e Level 4 PIN change menu K a F1 Selects Staff PIN setup mode F2 Selects Operator PIN F3 Selects Mimic PIN E G Operator Staff Mimic the same Warning As Operator ensure that you note your new PIN number or you will be locked out of your own system FEC can remotely reset for you Set new FIH Enter FIH Get new FIH Enter FIH Accert Hew FIH code stored_ PTH Setur HOHE z222 9990 Hew imi Exit Staff Urs fli D O O O The above example shows how the Operator can reset their own PIN Note the warning about forgetting the Operator PIN you will be locked out of your own system and only have User privileges until reset lf an Operator does lock themselves out FEC will be able to remotely reset Entering a new PIN is also possible via SMS Version 1 0 Issue 3 07 July 2014 Page 24 of 36 Interleader Ltd 2014 FEC Remote Lighting Controller HP0656 User Installation and Operation Manual 6 4 2 System Test Menu There are three options currently in the System Test Menu 1 Testing the GSM link between the Remote Panel and the RLC 2 Test the Siren and 3 Showing system information te ee Moe Level 4 System Test Menu Bees core sce for ao F1 Performs GSM Link Test with Helipa
9. 4 Lay the controller front panel face down on a protective flat surface 5 Double click on the update file and a screen similar to that to the top right will appear To install software version 01 02 6 Connect the USB cable to the PC deeg 7 Hold down the Boot loader switch at the same ne egener tt time as connecting to the USB port on the rear of the controller image right this will power the controller from the PC 8 The screen on the PC should now advise that the eae ee E system is connected and the Install button will ee art eAGLe changed from greyed out to active 9 Click Install and the software will be automatically uploaded to the controller checked 10 A screen right confirms the update in progress FEC Software Updo 11 When complete click finish and the window will To install software version 01 02 close KR Firmware version 01 02 is now 12 If Windows asks if the programme installed ok SE click yes 13 Disconnect the USB cable 14 Reassemble the controller and turn on ach See 15 The controller will now be running the new software validated in Show Systems Data menu Version 1 0 Issue 3 07 July 2014 Page 33 of 36 Interleader Ltd 2014 FEC Remote Lighting Controller HP0656 User Installation and Operation Manual 13 Appendix 3 Factory Default Settings The following are the Factory default settings nem 1 Dotat Seting Gemen Operator PIN A S Mimic Pad PIN man
10. M aerial option pack is available Version 1 0 Issue 3 07 July 2014 Page 10 of 36 Interleader Ltd 2014 FEC Remote Lighting Controller HP0656 User Installation and Operation Manual 4 8 Mains wiring The arrangement of the base unit is shown below L Ce A 12V DC 30W Mains PSU 100 240VAC an GI uge DS KEE EZ Pat gt n LES MERUN AN E UT N e q sek Do nat apen PSU and Siren Interface Board very MNA DIN Rail mounted connector strips Customers may add additional items Position of optional GSM connector Mains cable Sounder Pol a TS Ae le gland Notes 1 Live Brown Neutral Blue and Earth Green Yellow 4mm IMO DIN rail mounted connector strips are provided for customer wiring 2 Additional connectors can be added by the customer but pay particular attention to a Such connectors are often open on one side Care must be taken to ensure that the open side is always covered by its neighbour or end plate b The earth connector is fixed and grounded to the DIN rail by a central screw To move this connector slacken the central screw move as required and re tighten c The Earth connector provides the earth bonding connection to the controller d The connectors must be gently pushed tight against the PSU and Relay Interface Board to ensure that these items are prevented from sliding on the rail 3 The controller is fitted with a mains powered 12V Power Supply Unit PSU
11. Sech ech bea The main menu options are ai Ess GSM Setur Exit F1 Enables helipad light circuits to be z activated or de activated Returns to Main Menu if Link Test not done F2 Sets up and tests the GSM module and link to the helipad F3 Set up and monitor system variables Circuit Change Mery Link Hot Established Pertorm Link Test Circuit Change Meru Setur GSM Unit Setur Unit is Et oa Press soft ZC SE Press soft keys for Or Or Or Exit Clock Hoz xit PINs Test Setur Exit j Le D 0 0O hE D 0 0 0 o D There are three main setup areas Lights GSM and Setup In the following sections we will go through each of these areas in turn Version 1 0 Issue 3 07 July 2014 Page 16 of 36 Interleader Ltd 2014 FEC Remote Lighting Controller HP0656 User Installation and Operation Manual 6 2 Lights Menu The RLC Remote Panel can be used to turn circuits Lights on and off As the system uses a Mobile Phone Cell Phone SMS link just as with any SMS the number to be called must be entered into the system before the command can be sent From the menu on the left an attempt has been made to turn on channel 1 If no Pad number has previously been entered the request is rejected If it has there is a challenge menu followed by confirmation that the Set request has been sent In the menu on the right circuit 1 is already on The same request is this time accepted because the Pad number has been
12. Set Unit ID Current ID Enter Hew Setur Unit Uperat ior Setup Unit Operation Current ID B LB Heater LCD Hester Heu Unit ID Autg Auto ID Exit Or IFF ID Exit LK Hei a y D D AB E o 8 8 LCD By default the LCD display Backlight is On Optionally it can be set to Auto to save power In auto mode the backlight goes off if no key is pressed or message sent to the screen for ten minutes Touching a key or sending a message to the screen will immediately turn the back light back on again Heater By default the heater is in Automatic mode As the internal temperature of the box drops towards freezing the heater is run increasingly hard to maintain the keyboard display and electronics at a temperature above freezing In a battery powered system the heater can be turned off to conserve power ID A four digit number between 0000 and 9999 can be entered to identify this unit This identifier is prefixed to all outgoing SMS messages to identify the source Version 1 0 Issue 3 07 July 2014 Page 28 of 36 Interleader Ltd 2014 FEC Remote Lighting Controller HP0656 User Installation and Operation Manual 7 Normal Operation When operating normally with the link tested and the helipad lights off the main screen will be showing When the lights are activated the screen will change to the middle screen and the siren will sound Age Gelee Level 1 Basic Operation Emil HSE be SR bier channels off Oo O O LU F1
13. The installer must connect this to the incoming mains supply via the fuse provided using Suitable 3 core cable 3x0 75mm The PSU is double insulated and is not earthed Version 1 0 Issue 3 07 July 2014 Page 11 of 36 Interleader Ltd 2014 FEC Remote Lighting Controller HP0656 User Installation and Operation Manual 4 9 Inserting the SIM While the front panel including the keypad and LCD are disconnected and before re assembly the SIM should be fitted The SIM is located behind a rotating flap on the back of the keypad unit below left To fit SIM 1 Slacken the two screws using a Philips PH1 2 or Pozidrive PZ2 screwdriver There is no need to remove the screws or plate 2 Rotate the flap clock wise as shown 3 Slide the plastic SIM carrier gently to the right and then pull forward 4 Insert the SIM into the plastic SIM carrier metal contacts to the left inside and the ident corner downward Close the flap making sure that the SIM is in correctly aligned and properly seated 6 Slide the plastic SIM carrier to the left until a click is heard or felt 7 Rotate the flap back into place and gently re tighten the screws 4 10 Final Assembly Re attach the ribbon cable between the front panel unit and the base unit 5 ll E Re assemble the front cover to the base unit and tighten the retaining screws firmly but not too tight Take care that 1 All connectors and cables are secure and that the
14. age AC Electrical Protection Operating voltage DC Max voltage range DC Power standby Power GSM transmitting Max power consumption Size Weight with shipping packaging Warranty Protection Environmental Version 1 0 Issue 3 Interleader Ltd 2014 FEC Remote Lighting Controller HP0656 User Installation and Operation Manual 2 GSM SMS or Keypad Tri Band Operators choice subject to coverage Account recommended or pre pay Externally mounted on unit Optional SMA or BNC for Remote mounting IP65 general IP65 and vandal resistant 25 C to 50 C 25 C to 80 C ROHC Compliant except exempt items radios 100 240V AC 50 60Hz 5A 20mm Fuse 12V DC 10V 15V DC 3 watts approx 10 watts maximum 30 watts including optional winter heater Height 11 280mm Depth 6 5 165mm Width 7 180mm 5 5lbs 2 5kg 3 9kg 2 years return to FEC excluding relays IP65 07 July 2014 Page 30 of 36 FEC Remote Lighting Controller HP0656 User Installation and Operation Manual 9 Power Supply Unit Specification All specifications are manufacturer s data Manufacturer Meanwell Manufacturers Model No DR 30 12 Universal AC input Full range 100 240V AC 50 60 Hz Input current 1 1A Protections Short circuit Over load Over voltage Cooling by free air convection Can be installed on DIN rail TS 35 7 5 or 15 Isolation class LED indicator for power on 100 full loa
15. are required To use this gland simply remove the plug If replacing do not over tighten as this may permanently damage the gasket Version 1 0 Issue 3 07 July 2014 Page 9 of 36 Interleader Ltd 2014 FEC Remote Lighting Controller HP0656 User Installation and Operation Manual 4 5 Installing the GSM aerial The GSM aerial is shipped attached to the outer packaging Carefully remove it from the plastic bag and screw onto the external aerial connector on the top of the base unit Do not over tighten as this may permanently damage the aerial or socket but ensure it is fully home Be careful when handling the front panel to ensure that the aerial is not damaged 4 6 Electrical Installation lt is recommended that mains cables are fixed first to avoid damage to aerial or signal cables If the Remote Panel is to be operated from a mains power supply it must be connected to the Supply using a fused double pole isolator The controller has a maximum power consumption of 30watts so if the supply is only powering the controller the switched circuits being separate then a 5 Amp fuse should be used 4 7 Circuit Connector and Cable Entry The Picture below shows the connectors and cable entry arrangements on the bottom of the base Optional GSM connector position Mains input cable gland Notes 1 An external GSM aerial is fitted on top of the unit and should prove sufficient for most installations If necessary an external GS
16. ation ensure that you have at least the following items in addition to those required for the rest of the installation 1 A No 2 Philips PH2 or No 2 Pozidrive PZ2 screwdriver to open the main enclosure 2 A No 0 or 1 Philips PH1 2 or No 1 Pozidrive PZ1 screwdriver to access SIM cover 3 The SIM standard size not mini or micro that you will be using You will need to know the number to call it but the controller does not need to know 4 Fixing screws and wall plugs as required 4 3 Preparing for Installation Lay the Remote Panel on its back on a clean soft surface at least twice the width of the unit and undo the four corner retaining screws note these screws are captive and do not need to be fully removed Gently lift the front of the enclosure away from the base and lay face down to the left of the base unit Be careful not to strain the cables as this could cause permanent damage Disconnect the following cables from the keypad enclosure 1 Main power and relay controller ribbon cable 2 Earth bonding lead Note 1 may have retaining screws Use a PH1 2 or PZ2 screwdriver to remove and use a small amount of Loctite 248 Medium Strength thread locking compound on re assembly Version 1 0 Issue 3 07 July 2014 Page 8 of 36 Interleader Ltd 2014 FEC Remote Lighting Controller HP0656 User Installation and Operation Manual 4 4 Installing the Base Unit Either by measurement or using the template in Append
17. d Link Siren Logs Exit F2 Tests the Siren o o o ae l F3 View system information Level 5 Siren Test F1 Turns Siren On F2 Turns Siren Off F4 Quit to System Menu System Test Mode Sere fea i Show System Data Press soft keys for Press soft keys a Press soft keys for Link Siren Logs Exit m o wie Mait Sus Logs Para Exit DU D D 8 Version 1 0 Issue 3 07 July 2014 Page 25 of 36 Interleader Ltd 2014 FEC Remote Lighting Controller HP0656 User Installation and Operation Manual 6 4 3 Link Test The Link Test sends a status request to the Helipad RLC If no Pad number has been entered then this is advised and the test aborted To continue store the Pad number see section 6 3 3 lf a Pad number is stored then a request is sent and the system returns to the main screen Level 5 Link Test Menu F1 Select Link Test Link Test will not be performed unless Pad number has been entered SM Link Test GSM Link Test Ho 44 75545627787 Ho Urps Pad Ho Set Test iait Action Aborted Link Test Reayester Helirad Light Status Status Inactive Cl Eege Meru D O O o Version 1 0 Issue 3 07 July 2014 Page 26 of 36 Interleader Ltd 2014 FEC Remote Lighting Controller HP0656 User Installation and Operation Manual 6 4 4 Show System Information A number of configuration and system data are held and updated by the system This information is availab
18. d burn in test Approvals 10 Spare Parts The following spare parts are available and can be fitted by users There are no other user serviceable parts ltems requiring repair need to be returned to FEC Version 1 0 Issue 3 07 July 2014 Interleader Ltd 2014 Page 31 of 36 FEC Remote Lighting Controller HP0656 User Installation and Operation Manual 11 Diagnostics and Fault Finding The following are the range of simple tests that an end user of the controller can perform to be carried out in the order given Warning If the controller is mains powered the controller box will contain dangerous voltages A qualified electrician must perform all of the necessary safety checks on the unit prior to any other tests being carried out Basic Visual Checks Ensure that e The unit is properly mounted secure and appears physically undamaged e There are no signs of overheating e The wiring switches and fuses that power the unit are all working as expected Basic Operational Checks Ensure that e The PSU Status LEDs are as follows e 12 0V Lit e 5 0V Lit e 3 3V Lit e The LCD back light comes on when a key is pressed e The controller responds correctly to keypad inputs Basic Power Checks In the event that neither of the above works e Isolate the power and remove the front cover e Visually check that all of the cable are fitted correctly e Re apply power and observe determine if LEDs
19. entered 09 and 5 o clock in the afternoon 17 Immediately that the two numbers for the hours have been entered you are prompted to enter minutes Again this is as a two digit number Immediately the minutes have been entered the time is shown bottom left screen which you can accept F1 OK or reject and start over F2 New Once the time has been correctly entered the day of the month is prompted for Again this is in a two digit format The number is checked to be in the range 1 31 but does not check against the month which is entered in the same way again being checked to be in a valid range of 1 12 Once the month has been correctly entered you are prompted for the year The system pre fills the Century 20 and accepts all years from 13 99 On completion of the above there is a screen to confirm the date with the same options as before Pressing F1 accepts the date time and sets the clock Confirmation that the clock has been set is displayed for a short period before returning to the main menu Version 1 0 Issue 3 07 July 2014 Page 20 of 36 Interleader Ltd 2014 FEC Remote Lighting Controller HP0656 User Installation and Operation Manual 6 3 3 Set GSM Numbers The system can store three numbers 1 Operator Ops This is the number of the Owner Operator 2 Agency This number which is optional is the number to which only operational reports are sent This can be any third party that the Operator w
20. his is generally anyone who has been given permission to use the system Operator This is the owner or operator of the facility Agency A third party who the operator wishes to be informed of operational activity Pad The helipad system that is being monitored and controlled FEC FEC have defined access to certain options e g reset the Operators PIN OEM The Original Equipment Manufacturer has defined access to perform diagnostic and Support options The options available to FEC and OEM are explicitly defined as part of the supply agreement 3 2 Keypad Operation Most keypad input requires the user to enter a 4 digit password Failure to do so quits the option lf any of the menus below the main screen are entered but there is no keypad activity for 10 minutes the system will automatically return to the main screen This is to ensure that if someone was for example called away during a menu activity the unit will return to the safe armed condition 3 3 GSM SMS Operation Operational activity is limited to the User and Operator only as follows Action Statt Operator Comment Obtain Status Will automatically receive from the paired RLC Turn Circuit s ON All service requests require a correct PIN Turn Circuit s OFF d dh Note Staff can turn a circuit OFF only H they previously turned it ON An Operator can always turn circuits OFF irrespective of who turned it ON Set Staff Operator and d Mimic PINS
21. hting Controller HP0656 User Installation and Operation Manual 1 Overview FEC s Remote Lighting Controller is an all new fully digital design that combines ease of installation and use with sophisticated yet simple and secure configuration via the IP65 rated keypad and LCD display or via SMS The Remote Panel enables the status of the linked helipad to be monitored through the Remote Lighting Controller on the pad With appropriate PIN code protection the lights can also be controlled from the Remote Panel Installers and users must read both this manual and the manual for the Remote Lighting Controller together as the units operate as an integrated system 1 1 Key Features e FCC EU approved Integrated tri band GSM Telemetry Engine for SMS control e Secure PIN code protected SMS commands to monitor and control your installation e Secure SMS status reporting check out your installation remotely e Remotely activate Circuits 1 2 or 3 and have the status sent straight back to the panel e Internal Siren e Local and remote test and diagnostics integrated into the unit e Very low power consumption Approx 3W idle and less than 30W max including internal winter heater e Operates from 110 240V AC 50 60Hz or 12V DC ideal for solar and batteries 1 2 Part Numbers Standard Equipment Remote Mimic Panel HP0655 Optional Extras Remote GSM Module Uninterruptable Power Supply Option Version 1 0 Issue 3 07 Jul
22. ion and Operation Manual 6 3 4 GSM Test Menu The system is able to perform the following tests on the GSM radio 1 Send a test text to the Operator number N B The Operator number must have been previously entered see section above 2 Receive a test message from any number maximum of 80 characters in the message and 3 Display the phone number of the last caller Caller ID CID mer root oa Level 6 GSM Test Menu _ est iio pass soft keys for F1 Send test message to Operator Number send Fecu CID Exit ae F2 Prompts for message to be sent and then displays it F3 Shows last caller ID Stine Lay giffen ye he Ah D In di 5SM Send Test to Urerator Ho ur to amp 44 OR 7849523 _ lona Version 1 0 Issue 3 07 July 2014 Page 22 of 36 Interleader Ltd 2014 FEC Remote Lighting Controller HP0656 User Installation and Operation Manual 6 4 Setup Unit Menu There are three options available to the Operator 1 Set PIN numbers 2 Test the system and 3 Configure the system e Level 3 Setup Unit Menu Setur Unit Press soft keys for NA F1 Selects PIN setup mode d Ae ISS ZE G R F2 Selects the test system mode F3 Selects system setup Version 1 0 Issue 3 07 July 2014 Page 23 of 36 Interleader Ltd 2014 FEC Remote Lighting Controller HP0656 User Installation and Operation Manual 6 4 1
23. ishes to keep informed of activity without the bother of having to manually alert them 3 Pad This number which is essential is the number of the Helipad RLC to allow remote monitoring and alerting of circuit activation Level 6 GSM Number Setting Menu Sou en DEE eh Use keypad amp Function Keys Press Sort kess for app To set numbers Ge nance Cad ait NB Must be full number Country Code Area Code Number Example is Operator Agency Pad are the same Urerator Number Urerator Number 4496 749523 OK Delete Exit Keypad Function Keys Operator Number __ aga sem CAN Cancels all entry 447907495273 20 44 7907 T CLR Cancels last entry 000 ENT Accepts number Return to Numbers In the above example the Operator number has been selected F1 The current Operator number is displayed middle left and in this case is blank as no previous number has been entered The required number is entered after the prompt part of the international dialling scheme Note in contrast to other screens the keypad CAN CLR and ENT keys are active lf an error is made CLR can be used to backspace and correct To clear the entire entry and start over press CAN To accept the number press ENT The process for entering the Agency and Pad numbers is exactly the same as for Operator Version 1 0 Issue 3 07 July 2014 Page 21 of 36 Interleader Ltd 2014 FEC Remote Lighting Controller HP0656 User Installat
24. ix 1 mark out and drill and plug the surface to which the Remote Panel is to be fixed gt LD e mm zm mm zm LA mm 4 off fixing holes in Fixing Holes 4 5mm dia 0 178 Maximum Screw Head Diameter 8 5mm 0 33 each corner Recommended Screw Size Metric M4 USA No 8 Enclosure Dimensions 250mm l 1 l l l l l l l l l l l l l l l l l l l l l l l l l l l lf the fixing screws are not in a convenient position for the surface on which the controller is to be fixed then the use of rails frames or battens is recommended DO NOT DRILL HOLES THROUGH THE ENCLOSURE BASE The fixing screws are in the same position as the top cover retaining screws The maximum screw diameter is 4 5mm 0 178 and a maximum head diameter of 8 5mm 0 33 Recommended screw sizes are Metric M4 or USA No 8 of a suitable length and type for the surface Mount the base of the enclosure and ensure that the fixing screws are secure but do not over tighten as this could damage the enclosure and compromise the IP65 rating Once the base has been fitted the unit can be wired up next section Take particular care not to damage the Power Supply Unit Relay Driver board and Relays during the installation of cables In anticipation that many installations will only require two cables to be fitted one of the cable glands is fitted with a nylon plug to ensure integrity of the enclosure if only two cables
25. le through this menu WS bat a Level 5 Display System Data Press soft keys for a F1 Shows system build data Ze SCH rara pet F2 Shows system logs F3 Shows system parameters Information is shown for 5 seconds and then returns to menu Reno iaht System ID FECOGOG PSU Voltage 12 14 FEC HoGa Hid 6i Activations 1 Unit Teme 29 10 Runtime 1H 25M LCD Backlight On Heat on GBH Go System Heater Huto System Shows the type and hardware amp software configuration History Logs Shows the system ID the number of times it has been turned on and off activations the total unit run time and the time the heater has run for System Parameters Shows the current Power Supply Unit PSU voltage and unit temperature and the configuration of the LCD Backlight On default or Off and heater Auto Default or Off Note that if the unit is being run from a 12V battery the PSU voltage will indicate the battery voltage Version 1 0 Issue 3 07 July 2014 Page 27 of 36 Interleader Ltd 2014 FEC Remote Lighting Controller HP0656 User Installation and Operation Manual 6 4 5 Setup Unit Operation There are two main options 1 Control of the LCD backlight and internal heater for power management and 2 Set Unit ID Level 5 Setup Unit Operation PERE Unit Ureration VV F1 Toggles LCD mode Auto On default Auta i cit F2 Toggles Heater Off Auto default ll d H H F3
26. lity 3 FEC Technical staff from FEC 4 OEM The Original Equipment Manufacturer Each type of user has a PIN access code and can perform a variety of configuration and other tasks on the system Using the numeric PIN code enter the 4 number PIN code As each number is pressed it replaces the relevant box until four numbers are entered NB As an additional security measure if numbers are not entered within 5 seconds of each other the screen times out and returns to the main menu Also if the wrong code is given this is advised and a return made to the main programme Main Screen before link test Main Screen after link test Helirad Light Status Level 1 Main Screen Helirad Light Status Status Inactive At power up the system requires sm a Link Untested Meru that the GSM link to the Helipad Bill Pee ies Meru irik i BEE is tested before other function G 2 2 e F4 selects the main menu FIH Security Check Enter FIH gooo Baal A iS Menu D O O O FIH Securit Check Enter FIH gooo Link Untestec Menu Test Link ist These symbols will be used In subsequent sections to aid menu navigate Lights GSM System Version 1 0 Issue 3 07 July 2014 Page 15 of 36 Interleader Ltd 2014 FEC Remote Lighting Controller HP0656 User Installation and Operation Manual 6 1 Setup Control Menu Once the correct PIN has been entered the Setup menu is entered Level 2 Main Menu Lc antr al
27. on PSU and Relay board are lit see earlier section e If so are the LEDs in the back of the Keypad enclosure lit lf all of the above are OK but the LCD is still not backlit and the keypad does not work there is a fault that requires the unit to be returned for repair Version 1 0 Issue 3 07 July 2014 Page 32 of 36 Interleader Ltd 2014 FEC Remote Lighting Controller HP0656 User Installation and Operation Manual 12 Appendix 1 Software Updater The FEC RLC Remote Panel can be updated with new Ftcsottware updater software in situ To install software version 01 02 To update the software requires a Windows PC and a No System connected USB cable with type A plug one end and type B the other The installer requires neither software nor drivers to be installed on your PC the standard Windows HID drivers already installed are used software updates can be emailed to you as a self extracting Zip file To update the software initiated through the Boot loader Switch The following is the simplest way of initiating the Connect System to be updated uploading of new software 1 Read the instructions and information contained in the readme file that is sent with the new software 2 Turn the unit off and disconnect from the normal a power source 3 Open the enclosure as described in earlier sections open carefully and disconnect aerial and ee connecting cable and earth wire
28. ress soft kesas for upeo AG GahlsuUi 10 Ors e Klee Pad Exit 0O O Selecting the Tech option initiates a read of the GSM module NB It may take up to 30 seconds for the module to be read and the data displayed The data are displayed in three groups 1 Time and Date T HH MM D YYYY MM DD Example shown is 14 14 on the 3 July 2014 2 The GSM module type and software version and build date and 3 The GSM signal strength on a scale of 0 no signal to 100 Max signal strength Typical operating range is 60 80 Once the data have all been displayed there is a pause of a few seconds and then the system returns to the Setup Read GSM Unit menu Version 1 0 Issue 3 07 July 2014 Page 19 of 36 Interleader Ltd 2014 FEC Remote Lighting Controller HP0656 User Installation and Operation Manual 6 3 2 Set GSM Clock selecting Clock from the previous menu starts the clock setting process Level 6 Clock Setting SetuP GSM Dat Ap L Set Day 2090 app Use keypad amp Fn Keys Enter Mo 9000 SE To set Time amp Date Setur GSM Time Set Minutes Enter Ho 20 d Chr D A LA Ou en T O Ow M 2s Cf cf iD p ER d ln O di CO Ti Setur GSM Time tur GSM Date at SSM Unit Clock Set T 1 Me R ji S R 24 Voor att a ka ks OK New xit Ler 2 2410 NV The first screen requests the hour This must be entered in 24 hour format and as a two digit number For example 9 o clock in the morning would be
29. stored Following a challenge menu there is confirmation that the Clear request has been sent Lights Menu All Circuits Off Level 3 Change Circuit Lights Menu Circuit 1 On Lights Menu F1 F3 Change the status SE e EE i of Channels 1 3 Et Un Action aborts if no Helipad e number set Circuit Change Meri Circuit Change Meru Level 4 Change Circuit No Ors Pad Ho Set Change Circuit 17 Confirmation hetion Aborted a SE F1 Confirms Set Clear F4 Quits to previous menu Set Circuit Sent_ Clear Circuit Gent Note that in both cases the system will return to the main screen which will be showing the status before the command was sent Once the unit receives confirmation that the demanded action has taken place the display will change accordingly Version 1 0 Issue 3 07 July 2014 Page 17 of 36 Interleader Ltd 2014 FEC Remote Lighting Controller HP0656 User Installation and Operation Manual 6 3 Setup GSM SMS Unit If the GSM receiver was on when Setup was selected then the screen will appear as follows Seture GSM SMS Unit Level A GSM Main Menu Press soft keys for joc F1 Toggles the GSM radio On and Off Off Setur TxRx Exit JOC Ke S o o skal Solid square indicates On S F2 Selects the setup menu F3 Selects the Transmit Receive test menu Exit Leaves the menu with the GSM On or Off as at time of exit Setur GSM SMS Unit ess soft keys for
30. w n fe a L il HELIPORTS amp HELIPORT EQUIPMENT aa oan a yw e A Me e Remote Lighting Controller Remote Panel Mimic FEC Type HP0655 User Manual Specification Diagnostics Version 1 0 Issue 3 7 July 2014 Note that this manual relates to Hardware V1 3 and Software V1 03 Powered by eAGLe Light Engines e g ff Interleader Limited eAGLe FEC Remote Lighting Controller HP0656 User Installation and Operation Manual Contents Te e E 5 Ui WRC E 5 E ng NOMD aes psec nee cogee E 5 2 Architecture of Remote Lighting Controller nannnnannnnnnnnannnennnnnnnnnnnnnnrnnnnnnnnnnnnrrennrennennne 6 CR eelere le Ee e 7 SS GNT eee E ee ee eee ee ee 7 22 Kya 0 921 e 7 2 fm i o M le EE 7 Se EE a WE 8 At LOCAUNGING REMO I AMC I cccecacacccecadwncatencencatanaecsununeuanseueynsadusaenadnseuncadponensesnceyacduecbare 8 SC ANOS VOU WU SC eeen EE E EE EE EEEE E EE 8 AO Prepanng Tor installalo sece Ee E E E RE GE TERET 8 AG MNG Base AN e EEE EEE EEEE 9 4 5 Installing the GSM aena 10 4 6 Electrical Iosiallanon ccc ccccccccecceeeseeeeeeceeeceeeseeeseeeeueceeesaeeseeeeeeesueeeeeseeeseeeseeeaees 10 4 7 Circuit Connector and Cable Ent 10 4 8 Mains Wiring secascccxtcneachaaenancntoaaconanteanseatiinstuenanecenanechaushancbenasiuey seen menndienteancieraeeeciounerieaee 11 dO MSEE o Meee EEE EEEE E 12 ATO FRIAS ue A EE 12 5 BASIC Operaion 13 NTO E TEE 13 o2 DNS MAIN CCO eege 14 5 2 1
31. y 2014 Page 5 of 36 Interleader Ltd 2014 FEC Remote Lighting Controller HP0656 User Installation and Operation Manual 2 Architecture of Remote Lighting Controller Key to Links GSM Link Fixed Lighting Ga VHF Link Wired Link Remote Monitoring amp Control Direct input Local Monitoring amp Control The FEC RLC Remote Panel Mimic is designed to work as an integral part of a complete Helipad Lighting system The Remote Panel can be located conveniently for the staff who are required to monitor and or control the activity of the helipad lights The secure wireless link between the RLC and Remote Panel is via GSM SMS and only requires a mains power supply In areas of poor GSM signal coverage an optional Remote GSM Module is available see Appendix for details Version 1 0 Issue 3 07 July 2014 Page 6 of 36 Interleader Ltd 2014 FEC Remote Lighting Controller HP0656 User Installation and Operation Manual A Principles of Operation The FEC RLC Mimic adopts a set of simple but key principles in its mode of operation These principles which guide how the system works are outlined below 3 1 General The controller is designed to fail safe For example If power is lost at any time on resumption of power the controller will re start and advise that the link needs to be re tested to confirm that helipad lighting status There are a number of Types of users of the system Staff T
32. y are not caught in anything 2 The enclosure retaining screws are screwed in evenly and firmly but not too tight You are now ready to configure the unit section 6 Version 1 0 Issue 3 07 July 2014 Page 12 of 36 Interleader Ltd 2014 FEC Remote Lighting Controller HP0656 User Installation and Operation Manual 5 Basic Operation 5 1 Menu Overview The FEC RLC is fully configurable via the front panel keypad and screen All setup test and monitoring of the controller is carried out via the front panel keypad and LCD display many commands also possible remotely via SMS see later section There are no controls inside the case The menus are arranged in an hierarchical structure with a consistent presentation format and key operation Extensive use is made of the 4 Function Keys above the main 16 key keypad and in conjunction with changing legends on the screen intuitively guide the user through the various steps Key features of the interface are shown below LCD Screen Common Layout Line 1 indicates the menu level Line 2 provides status or instruction Line 3 Indicates the Function Keys function Line 4 identifies the keys and their status Function Keys 1 4 left to Right Data Entry Keypad In the example to the left The 1 line indicates Main Screen Level The 2 line indicates inactive helipad lights are The 3 line confirms the function of each key The 4 line represents the Function Keys

Download Pdf Manuals

image

Related Search

Related Contents

取扱説明書  USER`S MANUAL  Manual CG 1800  Dataflex ViewMaster M5 Monitor Arm 203  NEC 入力電圧 ACー 〇〇〉 周波数 50/60Hz 入力電流 〇・36A  READ AND SAVE THESE INSTRUCTIONS  Android Media Player  

Copyright © All rights reserved.
Failed to retrieve file