1. m A 0 Io 0 Efo qE D d OCTOPUS 16M 8P0E OCTOPUS 16M 8P0E 2FX Figure 1 PoE capable ports in the OCTOPUS PoE devices 1 port without PoE 2 port with PoE OCTOPUS 8M 16M 24M Release 05 03 10 11 2 Assembly and start up The devices have been developed for practical application in a harsh indus trial environment The installation process is correspondingly simple On delivery the device is ready for operation The following procedure has been proven to be successful for the assembly of the device Unpacking and checking Connecting the plug for the supply voltage and the signal contact Installing the device and grounding Connecting the supply voltage starting up Connecting the data lines 2 1 Installing the device 2 1 1 Unpacking and checking L Check whether the contents of the package are complete see page 28 Scope of delivery L Check the individual parts for transport damage 2 1 2 Connecting the plug for supply voltage and signal contact The supply voltage and the signal contact are connected by means of a 5 pin M12 connector A coding e g ELWIKA 5012 PG7 from Hirschmann included in the delivery Connecting the supply voltage The supply voltage can be connected redundantly Both inputs are uncou pled There is no distributed load With redundant supply the power sup ply unit suppli
2. A break in contact is used to report the following conditions via the poten tial free signal contact relay contact closed circuit The failure of at least one supply voltage A continuous malfunction in the device The loss of connection at at least one port The report of the link status can be masked by the Management for each port In the delivery state link status monitoring is deactivated The loss of ring redundancy reserve A detected error during the self test Incorrect configuration of the HIPER Ring or ring coupling The following condition is also reported in RM mode Ring redundancy reserve is available On delivery there is no ring re dundancy monitoring C Connecting the supply voltage and signal lines OCTOPUS 8M 16M 24M 14 Release 05 03 10 2 1 3 Installing the device and grounding Installing the device To protect the exposed contacts of the components still to be installed from dirt connect the individual system components in a dry and clean working area Seal unused ports with the protection caps supplied Note Connectors are not electrical isolating devices Therefore first plug the connector into the power supply plug and then switch on the power supply L Install the device in a location where the climatic threshold values specified in the technical data are adhered to Make sure the environment does not heat the device It can be mount ed on temperature isolating material LI Prepare the drill
3. 493 5 Btu IT h OCTOPUS 16M 2FX 13 0 W 44 4 Btu IT h OCTOPUS 16M 8PoE 2FX non PD powered device 17 0 W 57 9 Btu IT h 8 x ClassO PD 150 0 W 510 5 Btu IT h OCTOPUS 24M 13 5 W 46 0 Btu IT h OCTOPUS 24MTrain 13 5 W 46 0 Btu IT h OCTOPUS 24M 2FX 14 9W 50 9 Btu IT h Scope of delivery Note The cable socket ELWIKA 5012 PG7 933 175 100 included in the delivery supports a temperature range from 25 C to 70 C It can thus restrict the possible range of usage for the overall system You can obtain special sockets with protection class IP67 and an extended temperature range on request OCTOPUS 8M 16M 24M 28 Release 05 03 10 Device Scope of delivery OCTOPUS device Cable socket ELWIKA 5012 PG7 for supply voltage and sig OCTOPUS 8M OCTOPUS 8M Train OCTOPUS 8M 8Po0E OCTOPUS 8M 6Po0E OCTOPUS 16M OCTOPUS 16M Train OCTOPUS 16M 8P0E OCTOPUS 16M 2FX OCTOPUS 16M 8PoE 2FX OCTOPUS 24M OCTOPUS 24M Train OCTOPUS 24M 2FX Order numbers product description Device nal contact 9 for OCTOPUS 8M 17 for OCTOPUS 16M and 25 for OCTOPUS 24M protective caps for sealing unused ports Installation user manual and CD ROM Order number OCTOPUS 8M 943 931 001 OCTOPUS 8M Train 943 983 001 OCTOPUS 8M 8PoE 943 967 001 943 967 101 OCTOPUS 8M 6Po0E OCTOPUS 16M 943 912 001 OCTOPUS 16M Train 943 984 001 OCTOPUS 16M 8PoE 943 960 001 OCTOPUS 16M 2FX
4. 8M 16M 24M 8 Release 05 03 10 1 Device description The OCTOPUS devices are designed for the special requirements of indus trial automation They meet the relevant industry standards provide very high operational reliability even under extreme conditions and also long term reliability and flexibility The devices operate without fans and have a re dundant voltage supply The HIPER Ring redundancy concept enables you to quickly carry out a re configuration and also a simple configuration with only one additional con nection It can be easily managed via a Web browser via Telnet with a management software product Such as HiVision or locally on the switch V 24 interface The devices allow you to set up switched industrial ETHERNET networks that conform to the IEEE 802 3 and 802 3u standards using copper wires or optical fibers in a line or ring structure You can connect terminal devices and other infrastructure components via twisted pair cables and F O The twisted pair ports support autocrossing autonegotiation and autopolarity Depending on the software you choose the devices provide you with a large range of functions Redundancy functions Rapid Spanning Tree Redundant Ring Structure HIPER Ring Redun dant Coupling Link Aggregation Redundant Power Supply Protection from unauthorized access Synchronized system time in the network Network load control Operation diagnosis Diagnostics hardware self testing
5. D IEEE 802 1 D 1998 IEEE 802 1 Q IEEE 802 1 Q 1998 IEEE 802 1 w 2001 IEEE 802 3 2002 Safety for Industrial Control Equipment Railway applications EMC emitted interference and interfer ence immunity for signal and telecommunication systems Railway applications electronic systems in railway vehicles IT equipment radio interference characteristics Generic norm immunity in industrial environments Programmable logic controllers Code of Federal Regulations Ship Applications Classification and Construction Guidelines VI 7 3 Part 1 Ed 2003 Switching GARP GMRP Spanning Tree Media access control MAC bridges includes IEEE 802 1p Pri ority and Dynamic Multicast Filtering GARP GMRP Tagging Virtual Bridged Local Area Networks VLAN Tagging GVRP Rapid Reconfiguration Ethernet RL 72 245 EWG 2009 19 EG e1 type certification for use in vehicles Table 10 List of norms and standards Certified devices are marked with a certification indicator From the imprint on the device label you will see the current certification status of your device Certifications Standard cUL 508 CSA C22 2 No 142 German Lloyd e1 type certification FCC 47 CFR Part 15 2009 EN 50155 EN 50121 4 2006 EN 61131 2 2007 OCTOPUS OCTOPUS PoE OCTOPUS Train without PoE Yes pending No Yes pending No Yes Yes No Yes Yes Yes No pending Yes No No Yes Yes Yes Yes Table 11 Certifications for the current st
6. Reset Priority VLAN Topology Discovery Web based Interface Command Line Interface CLI SNMP 802 1x port authentication Real Time Clock The addition to the OCTOPUS range of the Open Rail range the MICE range the MACH range of backbone switches the BAT wireless transmis sion system the EAGLE security system and products for the LION control room provides continuous communication across all levels of the company OCTOPUS 8M 16M 24M Release 05 03 10 9 1 1 Description of the device variants 1 1 1 Devices without Power over Ethernet The following device variants provide 8 to 24 10BASE T 100BASE TX ports RJ45 connections for connecting network segments or terminal devices OCTOPUS 8M OCTOPUS 8M Train OCTOPUS 16M OCTOPUS 16M Train OCTOPUS 16M 2FX OCTOPUS 24M OCTOPUS 24M Train OCTOPUS 24M 2FX The OCTOPUS 8M Train OCTOPUS 16M Train and OCTOPUS 24M Train devices are certified for railway applications electronic systems in railway vehicles in accordance with EN 50155 Device Number of FX Number of TX Ports Ports OCTOPUS 8M OCTOPUS 8M Train 8 OCTOPUS 16M OCTOPUS 16M Train 16 OCTOPUS 16M 2FX 2 16 OCTOPUS 24M OCTOPUS 24M Train 24 OCTOPUS 24M 2FX 2 24 1 1 2 Devices with Power over Ethernet The following device variants i e OCTOPUS PoE support Power over ETHERNET PoE in accordance with IEEE 802 3af OCTOPUS 8M 8Po0oE OCTOPUS 8M 6Po0E OCTOPUS 16M 8PoE OCTOPUS 16M 8P0E 2FX They all
7. at a distance of up to 5 cm 1 97 in from the device and relative air humidity L Install the device in a location where the climatic threshold values specified in the technical data are adhered to Make sure the environ ment does not heat the device It can be mounted on temperature iso lating material L Only to be used in an environment with the contamination level speci fied in the technical data Qualification requirements for personnel Qualified personnel as understood in this manual and the warning signs are persons who are familiar with the setup assembly startup and oper ation of this product and are appropriately qualified for their job This in cludes for example those persons who have been trained or directed or authorized to switch on and off to ground and to label power circuits and devices or systems in accordance with current safety engineering standards trained or directed in the care and use of appropriate safety equipment in accordance with the current standards of safety engineering trained in providing first aid General safety instructions Please note that products recommended as accessories may have char acteristics that do not fully correspond to those of the corresponding prod uct This may limit their possible usage in the overall system Electricity is used to operate this equipment Comply in every detail with the safety requirements specified in the operating instructions regarding th
8. requirements C Use a shielded CAT5 cable O Use a shielded 4 pin M12 plug C Connect the cable shield to the connector housing 10 100 Mbit s twisted pair connection OCTOPUS POE 10 100 Mbit s ports M12 connector enable the connection of terminal devices or independent network segments according to the IEEE 802 3 100BASE TX 10BASE T and IEEE 802 3af Power over ETHERNET on data lines standards These ports support Autonegotiation Autopolarity Autocrossing if autonegotiation is activated OCTOPUS 8M 16M 24M Release 05 03 10 19 100 Mbit s half duplex mode 100 Mbit s full duplex mode 10 Mbit s half duplex mode 10 Mbit s full duplex mode Power over ETHERNET PoE State on delivery autonegotiation activated The socket housing is electrically connected to the housing The PoE voltage is input via pins 1 and 4 to the wire pairs transmitting the signal phantom voltage Figure Pin Color Function PoE PSE 3 4 1 White and or TX Transmit Data ange E 2 White and RX Receive Data 2 1 green 3 Orange TX Transmit Data 4 Green RX Receive Data Housing shield Table 4 Pin assignment of the TP TX interface for PoE for the voltage supply to the wire pairs transmitting the signal M12 socket L Install the data lines according to your requirements C Use a shielded CAT5 cable O Use a shielded 4 pin M12 plug C Connect the cable shield to the connector housing The patch cables for operating the dev
9. 039679002050310000 fh HIRSCHMANN A BELDEN BRAND User Manual Installation IP67 Switch OCTOPUS 8M OCTOPUS 16M OCTOPUS 24M D A A O ki 0 amp amp 0 q D f D a 0 0 0 z OCTOPUS 8M OCTOPUS 16M OCTOPUS 8M Train OCTOPUS 16M Train OCTOPUS 8M 8PoE OCTOPUS 16M 8PoE OCTOPUS 8M 6P0E 79 O A F 0 a z 0 2 oF OCTOPUS 16M 2FX OCTOPUS 16M 8P0E 2FX 0 A A O Ii 2 0 gt OCTOPUS 24M OCTOPUS 24M 2FX OCTOPUS 24M Train OCTOPUS 8M 16M 24M Release 05 03 10 Technical Support HAC Support Belden com The naming of copyrighted trademarks in this manual even when not specially indicated should not be taken to mean that these names may be considered as free in the sense of the trademark and tradename protection law and hence that they may be freely used by anyone 2010Hirschmann Automation and Control GmbH Manuals and sof
10. 1 1 Devices without Power over Ethernet 1 1 2 Devices with Power over Ethernet Assembly and start up Installing the device 2 1 1 Unpacking and checking 2 1 2 Connecting the plug for supply voltage and signal contact 2 1 3 Installing the device and grounding 2 1 4 Connecting the supply voltage starting up 2 1 5 Connecting the data lines Display elements Basic set up Technical data Further support OCTOPUS 8M 16M 24M Release 05 03 10 10 10 10 Safety instructions This documentation contains instructions which must be observed to ensure your own personal safety and to avoid damage to devices and machinery Certified usage Please observe the following The device may only be employed for the purposes described in the catalog and technical description and only in conjunction with external devices and components recommended or approved by the manufacturer The product can only be operated cor rectly and safely if it is transported stored installed and assembled pro perly and correctly Furthermore it must be operated and serviced carefully Supply voltage For safety reasons the devices have been designed to operate at low volt ages Thus they may only be connected to the supply voltage connec tions and to the signal contact with SELV circuits with the voltage restrictions in accordance with IEC EN 60950 1 The supply voltage is electrically isolated from the housing L Use only undamaged parts O Relevant f
11. 943 912 002 OCTOPUS 16M 8P0E 2FX OCTOPUS 24M 943 960 101 943 923 001 OCTOPUS 24M Train 943 985 001 OCTOPUS 24M 2FX Accessories 943 923 002 Note Some products recommended as accessories do not support the entire temperature range specified for the device They can thus restrict the possible range of usage for the overall system You can obtain special sockets with protection class IP67 and an extended temperature range on request Unsealed accessory parts such as RJ45 adapters or terminal ca bles are not suitable for use within an IP67 area Name Order number Pocket Guide 280 710 851 AutoConfiguration Adapter ACA21 M12 Terminal cable 943 913 001 943 902 001 Cable socket ELWIKA 5012 PG7 5 pin M12 socket for supply voltage and signal contact 933 175 100 RKC5 Duo Field attachable 5 pin M12 socket A coded with two cable outputs M12 connector D coded 934 445 001 934 497 00x Connection cable with M12 connector D coded Transition M12 D coded to RJ45 OCTOPUS 8M 16M 24M Release 05 03 10 934 498 001 29 Name Industrial HiVision Network Management software HiVision Network Management software OPC Server software HiOPC Order number 943 156 xxx 943 471 100 943 055 001 Underlying norms and standards Name cUL 508 1998 EN 50121 4 2006 EN 50155 2007 EN 55022 2006 A1 2007 EN 61000 6 2 2005 EN 61131 2 2007 FCC 47 CFR Part 15 2009 Germanischer Lloyd IEEE 802 1
12. Glowing green Valid connection Flashing green 1 time a period Port is switched to stand by Flashing green 3 times a peri Port is switched off od Flashing yellow Data reception Note You can query the port status for activated Power over Ethernet via the software management 2 3 Basic set up The IP parameters must be entered when the device is installed for the first time The device provides 6 options for configuring IP addresses Entry via V 24 connection Entry using the HiDiscovery protocol Configuration via BOOTP Configuration via DHCP Configuration via DHCP Option 82 Auto Configuration Adapter Further information on the basic settings of the device can be found in the Basic Configuration user manual on the CD ROM Default settings IP address The device looks for the IP address using DHCP Password for management Login user password public read only Login admin password private read and write Parameters that can be set via the management are set to pre defined values in accordance with the MIB V 24 data rate 9 600 Baud OCTOPUS 8M 16M 24M Release 05 03 10 23 Ring redundancy deactivated Ethernet ports link status is not evaluated signal contact Optical 100 Mbit s ports 100 Mbit s full duplex All other ports autonegotiation Ring manager disabled USB Interface ACA21 M12 The USB socket has an interface for the local connection of an AutoCon figuration Adapter ACA 21 M12 It is used
13. S 24M Train OCTOPUS 24M 2FX Grounding the device The device is grounded via the separate grounding nuts M3 L Use toothed washers to ensure good electrical conductivity at the con nection Note The shielding ground of the connectable twisted pair lines is con nected to the housing as a conductor OCTOPUS 8M 16M 24M 18 Release 05 03 10 2 1 4 Connecting the supply voltage E starting up Mount the connector for the supply voltage and the signal contact on the front of the device When you connect the supply voltage you start up the device 2 1 5 Connecting the data lines You can connect terminal devices and other segments at the ports of the de vice via twisted pair cables 10 100 Mbit s twisted pair connection 10 100 Mbit s ports enable the connection of terminal devices or indepen dent network segments according to the IEEE 802 3 100BASE TX 10BASE T standard These ports support Autonegotiation Autopolarity Autocrossing if autonegotiation is activated 100 Mbit s half duplex mode 100 Mbit s full duplex mode 10 Mbit s half duplex mode 10 Mbit s full duplex mode State on delivery autonegotiation activated The socket housing is electrically connected to the housing Figure Pin Function 3 4 1 TD Transmit Data 2 RD Receive Data 3 TD Transmit Data 9 1 4 RD Receive Data Housing shield Table 3 Pin assignment of a TP TX interface M12 socket L Install the data lines according to your
14. ates with regard to electromagnetic compatibility 72 245 EWG 2009 19 EG Guideline for standardizing the regulations of member states relating to radio interference from motor vehicles Certified devices are marked with an e1 type approval indicator Relevant for OCTOPUS 8M 8PoE OCTOPUS 8M 6P0E OCTOPUS 16M 8PoE OCTOPUS 16M 8Po0E 2FxX For use in connection with a suitable type approved power supply only OCTOPUS 8M 16M 24M Release 05 03 10 In accordance with the above named EU directive s the EU conformity declaration will be at the disposal of the relevant authorities at the follow ing address Hirschmann Automation and Control GmbH Stuttgarter Str 45 51 72654 Neckartenzlingen Tel 49 1805 141538 The product can be used in living areas living area place of business small business and in industrial areas Interference immunity EN 61000 6 2 2005 Emitted interference EN 55022 2006 A1 2007 Class A Warning A N This is a class A device This device can cause interference in living areas and in this case the operator may be required to take appropriate measures The assembly guidelines provided in these instructions must be strictly adhered to in order to observe the EMC threshold values FCC note Appropriate testing has established that this device fulfills the require ments of a class A digital device in line with part 15 of the FCC regula tions These requirements are designed to provide sufficient
15. atus visit www hirschmann com 30 OCTOPUS 8M 16M 24M Release 05 03 10 A Further support Technical questions and training courses In the event of technical queries please contact your local Hirschmann distributor or Hirschmann office You can find the addresses of our distributors on the Internet www hirschmann ac com Our support line is also at your disposal Tel 49 1805 14 1538 Fax 49 7127 14 1551 Answers to Frequently Asked Questions can be found on the Hirschmann internet site www hirschmann ac com at the end of the product sites in the FAQ category The current training courses to technology and products can be found under http www hicomcenter com Hirschmann Competence Center In the long term excellent products alone do not guarantee a successful customer relationship Only comprehensive service makes a difference worldwide In the current global competition scenario the Hirschmann Competence Center is ahead of its competitors on three counts with its complete range of innovative services Consulting incorporates comprehensive technical advice from system evaluation through network planning to project planing Training offers you an introduction to the basics product briefing and user training with certification Support ranges from the first installation through the standby service to maintenance concepts With the Hirschmann Competence Center you have decided against making any compromises Our clien
16. e voltages to apply see page 4 OCTOPUS 8M 16M 24M Release 05 03 10 5 Non observance of these safety instructions can therefore cause material damage and or serious injuries C Only appropriately qualified personnel should work on this device or in its vicinity These personnel must be thoroughly familiar with all the warnings and maintenance procedures in accordance with this oper ating manual L The proper and safe operation of this device depends on proper han dling during transport proper storage and assembly and conscien tious operation and maintenance procedures Never start operation with damaged components Only use the devices in accordance with this manual In particular ob serve all warnings and safety related information LI Any work that may be required on the electrical installation may only be carried out by personnel trained for this purpose Relevant for OCTOPUS 16M 2FX OCTOPUS 16M 8PoE 2FX OCTOPUS 24M 2Fx O Note LED or LASER components in compliance with IEC 60825 1 2001 CLASS 1 LASER PRODUCT CLASS 1 LED PRODUCT National and international safety regulations L Make sure that the electrical installation meets local or nationally ap plicable safety regulations Note on the CE marking The devices comply with the regulations contained in the following Euro pean directive s 2004 108 EG Directive of the European Parliament and the council for standardizing the regulations of member st
17. es Germanischer Lloyd Guidelines for the Performance of Type Yes Tests Part 1 IEC 870 2 2 table 3 normal installation according to EN Yes 61850 3 EN 61373 Category 1 Class A broadband noise Yes installation in acc with EN 50155 Shock IEC 60068 2 27 Test Ea test level according to IEC 61131 2 Yes IEC 870 2 2 table 3 normal installation according to EN Yes 61850 3 EN 61373 Category 1 Class A broadband noise Yes installation in acc with EN 50155 Network range TP port Length of a twisted pair segment typ 100 m cat5e cable with 100BASE TX Table 8 TP port 1OBASE T 100BASE TX OCTOPUS 8M 16M 24M Release 05 03 10 27 Connec Wave Fiber System Expansion Fiber data tion length attenua tion MicroFX MM 1300nm 50 125um 0 8 qB 0 5 km 1 0 dB km 800 MHz km MircoFX MM 1300nm 62 5 125um 0 11 qB 0 4 km 1 0 dB km 500 MHz km Table 9 F O port 100BASE FX MM Multimode SM Singlemode LH Singlemode Longhaul Power consumption power output Name Maximum Power output power con sumption OCTOPUS 8M 6 2 W 21 1 Btu IT h OCTOPUS 8M Train 6 2 W 21 1 Btu IT h OCTOPUS 8M 8PoE non PD powered device 10 0 W 34 0 Btu IT h 8 x ClassO PD 142 0 W 483 3 Btu IT h OCTOPUS 8M 6Po0E non PD powered device 10 0 W 34 0 Btu IT h 6 x ClassO PD 110 0 W 374 4 Btu IT h OCTOPUS 16M 9 5 W 32 4 Btu IT h OCTOPUS 16M Train 9 5 W 32 4 Btu IT h OCTOPUS 16M 8Po0E non PD powered device 13 5 W 45 9 Btu IT h 8 x ClassO PD 145 0 W
18. es the device alone with the higher output voltage The supply voltage is electrically isolated from the housing Note With non redundant supply of the main voltage the device reports a loss of power You can avert this message by applying the supply volt age via both inputs or by changing the configuration in the Management OCTOPUS 8M 16M 24M 12 Release 05 03 10 Figure Pin Function 4 3 9 1 24 V DC 1 2 Fault 5 3 OVDC 1 9 FAULT 4 24 V DC 2 5 5 Fault Table 1 Pin assignment of the 5 pin M12 connector for connecting the 24V supply voltage and the signal contact Connecting the PoE supply voltage optional The PoE supply voltage for OCTOPUS PoE devices is connected via a 5 pin M12 connector A coding e g ELWIKA 5012 PG7 from Hirschmann included in the delivery The OCTOPUS PoE devices are supplied with PoE voltage 48 V DC safety low voltage via an external power supply unit The PoE voltage is fed into the 5 pin M12 connector of the OCTOPUS PoE The twisted pair cables at ports 1 to 8 or 1 to 6 for the OCTOPUS 8M 6PoE are sup plied with PoE voltage via pins 1 and 4 to the wire pairs transmitting the signal phantom voltage LI Make sure that the external power supply unit you use to provide the PoE voltage fulfills the following basic prerequisites Insulation requirements according to IEEE 802 3af insulation re sistance 48 V output to rest of the world 2 250 V DC for 1 min Out
19. for connecting an external Management Station Note You will find the order number for the terminal cable which is or dered separately in the Technical Data chapter see on page 26 Tech nical data Note Available as an accessory for certain Hirschmann devices the AutoConfiguration Adapter ACA11 M12 is not designed to be used with OCTOPUS devices Use the ACA21 M12 if you want to use an AutoConfiguration Adapter for your OCTOPUS device USB socket of the OCTOPUS device see table 6 You will find a description of the V 24 interface in the Basic Configuration User Manual on the CD ROM OCTOPUS 8M 16M 24M Release 05 03 10 25 3 Technical data General technical data Dimensions WxDxH Weight Power supply Overload current protection at input Insulation voltage between operating voltage connections and housing FAULT signal contact Environment Operating tempera ture Protection classes 26 OCTOPUS 8M OCTOPUS 16M OCTOPUS 24M OCTOPUS 8M OCTOPUS 8M Train OCTOPUS 8M 8Po0E OCTOPUS 8M 6P0E OCTOPUS 16M OCTOPUS 16M Train OCTOPUS 16M 8P0E OCTOPUS 16M 2FX OCTOPUS 16M 8P0E 2FX OCTOPUS 24M OCTOPUS 24M Train OCTOPUS 24M 2FX Operating voltage OCTOPUS without PoE OCTOPUS PoE 189 mm x 184 mm x 70 mm 189 mm x 261 mm x 70 mm 189 mm x 338 mm x 70 mm 1 310g 1 920 g 1 950 g 2 540 g 2 5709 Safety extra low voltage SELV PELV redundant inputs disconnec
20. for saving loading the configu ration and diagnostic functions and for loading the software The USB interface is a shielded 5 pin M12 socket with A coding Figure Pin Function 4 1 Uin USB 5 V 2 N C Not used er 3 D Data 1 4 GND Ground 0 V 5 D Data Table 6 Pin assignment of the ACA21 12 M12 socket Note Available as an accessory for certain Hirschmann devices the AutoConfiguration Adapter ACA11 M12 is not designed to be used with OCTOPUS devices Use the ACA21 M12 if you want to use an AutoConfiguration Adapter for your OCTOPUS device USB socket of the OCTOPUS device see table 6 V 24 interface external management At the V 24 connection a serial interface is provided for the local connec tion of an external management station VT 100 terminal or PC with corre sponding terminal emulation This enables you to set up a connection to the Command Line Interface CLI and to the system monitor VT 100 terminal settings Speed 9 600 Baud Data 8 bit Stopbit 1 bit Handshake off Parity none The socket housing is electrically connected to the housing of the device The V 24 interface is not electrically isolated from the supply voltage OCTOPUS 8M 16M 24M Release 05 03 10 Figure Pin Function TX Transmit Data 3 4 1 2 RX Receive Data 3 N C Not used 2 1 4 GND Ground 0 V Table 7 Pin assignment of the V 24 interface M12 socket M12 5 DB9 M12 DB9 az ie a 2 1 A ae 5 Figure 7 Terminal cable
21. ght up The process takes around 60 seconds Orl O3 0000 os P1 P2 RM FAULT Uw _ 2 ae Figure 6 Display elements 1 Port status LEDs here for ports 1 to 4 2 Device status LEDs Device state These LEDs provide information about conditions which affect the opera tion of the whole device P1 Power 1 green LED Glowing green Supply voltage 1 is present Not glowing Supply voltage 1 is too low P2 Power 2 green LED Glowing green Supply voltage 2 is present Not glowing Supply voltage 2 is too low FAULT error signal contact red LED Glowing red The signal contact is open i e it is reporting an error Not glowing The signal contact is closed i e it is not reporting an error a Ifthe manual adjustment is active on the FAULT signal contact then the detected error dis play is independent of the setting of the signal contact OCTOPUS 8M 16M 24M 22 Release 05 03 10 RM Ring Manager green yellow LED Glowing green RM function active redundant port disabled Glowing yellow RM function active redundant port enabled Not glowing RM function not active Flashing green Incorrect configuration of the HIPER Ring e g the ring is not connected to the ring port Port state These LED s display port related information During the boot phase these LED s are used to display the status of the boot procedure LS data link status one green yellow LED per port Not glowing No valid connection
22. holes at the installation point L Mount the device on a level surface with four M5 screws Note Protection class IP67 is only achieved when the device is screwed on Protection class IP67 is only achieved when all the components connected fulfill protection type IP67 L Cover unused connections with the cover caps supplied L Only connect plugs and other components that fulfill protection class IP67 and that are certified for a temperate range from 40 C to 70 OCTOPUS 8M 16M 24M Release 05 03 10 15 cof amp amp amp gt 60 1885 Figure 2 Dimensions of OCTOPUS 8M OCTOPUS 8M Train OCTOPUS 8M 8PoE OCTOPUS 8M 6Po0E OCTOPUS 8M 16M 24M 16 Release 05 03 10 D D 120 150 169 188 5 a Figure 3 Dimensions of OCTOPUS 16M OCTOPUS 16M Train OCTOPUS 16M 2FX OCTOPUS 16M 8PoE OCTOPUS 16M 8P0E 2FX OCTOPUS 8M 16M 24M Release 05 03 10 17 D 338 2 326 4 D Figure 4 Dimensions of OCTOPUS 24M OCTOPU
23. ice are shown in the following fig ure OCTOPUS 8M 16M 24M 20 Release 05 03 10 ol _ x N R f TX 1 1 TX RX 2 x 2 RX TX 3 3 TX RX 4 x 4 RX 6 6 5 2 8 TX 1 1 RX RX 2 2 TX TX 3 3 RX RX 4 4 TX 6 6 5 3 9 TX 1 a 1 TX RX 2 x 2 TX TX 3 3 RX RX 4 6 RX 6 6 5 4 10 TX 1 1 RX RX 2 2 RX TX 3 x 3 TX RX 4 6 TX Figure 5 Patch cables for operating the device 1 Connection cables M12 4 on M12 4 crossed 2 Connection cables M12 4 on M12 4 1 to 1 3 Connection cables M12 4 on RJ45 crossed 4 Connection cables M12 4 on RJ45 1 to 1 5 M12 MDI 6 Shield 7 M12 MDI 8 M12 MDI X via autocrossing port 9 RJ45 MDI terminal device 10 RJ45 MDI X Switch 100 Mbit s F O connection MicroFX 100 MBit s LWL ports enable the connection of terminal devices or inde pendent network segments in compliance with the IEEE 802 3 100BASE FX standard These ports support Full duplex mode OCTOPUS 8M 16M 24M Release 05 03 10 21 Figure Pin Function 3 4 1 N C Not used 2 RX Receive Data 3 N C Notused 2 1 4 TX Transmit Data Table 5 Pin assignment of the MicroFX socket 2 2 Display elements After the operating voltage is set up the software starts and initializes itself Afterwards the device performs a self test During this process various LEDs li
24. or North America For use in Class 2 circuits The device may only be connected to a supply voltage of class 2 that fulfills the requirements of the National Electrical Code Table 11 b If the voltage is being supplied redundantly two different voltage sourc es the combined supply voltages must fulfill the requirements of the National Electrical Code Table 11 b O Relevant for North America For use in Class 2 circuits Only use copper wire conductors of class 1 75 C LI Relevant for North America for devices certified for hazardous locations Power input and output I O wiring must be in accordance with Class I Division 2 wiring methods Article 501 4 b of the National Electrical Code NFPA 70 and in accordance with the authority having jurisdiction Shielding ground Note The shielding ground of the connectable twisted pair lines is con nected to the housing as a conductor L Beware of possible short circuits when connecting a cable section with conductive shielding braiding OCTOPUS 8M 16M 24M 4 Release 05 03 10 Housing Only technicians authorized by Hirschmann are permitted to open the housing The device is grounded via the separate ground screw O Make sure that the electrical installation meets local or nationally ap plicable safety regulations Warning AN HOT SURFACE RISK OF BURNING Environment The device may only be operated at the specified ambient temperature temperature of the ambient air
25. ow the connection and remote supply of for example IP telephones Voice over IP webcams sensors printer servers and WLAN access points via 1OBASE T 100BASE TX With PoE these terminal devices are powered by the twisted pair cable Depending on the device variant the OCTOPUS PoE provides six to eight 1OBASE T 100BASE TX ports for connecting network segments or PoE terminal devices PD Powered Device for all IEEE802 3af classes up to a maximum power output of 15 4 W OCTOPUS 8M 16M 24M 10 Release 05 03 10 Device Number of FX Number of TX PoE capable TX Ports Ports Ports included OCTOPUS 8M 8P0E 8 8 port 1 to 8 OCTOPUS 8M 6P0E 8 6 port 1 to 3 and 5 to 7 OCTOPUS 16M 8Po0E 16 8 port 1 to 8 OCTOPUS 16M 8P0E 2FX 2 16 8 port 1 to 8 The current is supplied on wire pairs transmitting the signal the individual ports are not electrically insulated from each other The following conditions are met in accordance with IEEE 802 3af Endpoint PSE Alternative A G e ns 0 0 z 0 R q q a A Power over 6 ETHERNET 0 0 Wey 0 e ms go
26. protection against interference when the device is being used in a business environment The device creates and uses high frequencies and can radiate same and if it is not installed and used in accordance with this operating manual it can cause radio transmission interference The use of this device in a liv ing area can also cause interference and in this case the user is obliged to cover the costs of removing the interference Recycling note After usage this product must be disposed of properly as electronic waste in accordance with the current disposal regulations of your county state country OCTOPUS 8M 16M 24M Release 05 03 10 7 About this manual The following manuals are included as PDF files on the enclosed CD ROM User manual Installation User manual Basic configuration User manual Redundancy configuration Reference manual Web based Interface and Reference manual Command Line Interface The Network Management Software HiVision Industrial HiVision provides you with additional options for smooth configuration and monitoring Configuration of multiple devices simultaneously Graphical interface with network layouts Auto topology discovery Event log Event handling Client Server structure Browser interface ActiveX control for SCADA integration SNMP OPC gateway Legend The symbols used in this manual have the following meanings Listing O Work step Subheading OCTOPUS
27. put power lt 150 W Current limitation lt 5A Power supply unit and PoE media module form a limited power source according to IEC 60950 1 The external PoE power supply unit must be able to provide the power for the connected PDs 10 ms failure bridging incl Powered Devices in accordance with EN 61131 2 CE marking in accordance with 2004 108 EG Certified for railway applications electronic systems in railway ve hicles in accordance with EN 50155 L Connect the PoE voltage to the 5 pin M12 connector included in the scope of delivery as shown in the following diagram Make sure the the following requirements are met Supply line length lt 3m Supply line cross section is suitable for 3 3 A OCTOPUS 8M 16M 24M Release 05 03 10 13 Note Do not operate the OCTOPUS PoE devices in series Only con nect single external power supply units directly to an OCTOPUS PoE device Figure Pin Function 4 3 9 1 48 V DC 1 2 Fault 5 3 0V DC 1 9 FAULT 4 48 V DC 2 5 5 Fault Table 2 Pin assignment of the 5 pin M12 connector for connecting the PoE supply voltage and the signal contact FAULT signal contact The signal contact FAULT for pin assignment see table 1 is used for the remote monitoring of the device to enable remote diagnostics You can specify the type of function monitoring in the Management You can also use the Management to set the signal contact manually and thus control external devices
28. t ed Relevant for North America Nec Class 2 power source max 5A 9 6 to 60 V DC 46 to 58 V DC Non replaceable fuse OCTOPUS without PoE or Train 800 V DC OCTOPUS Train OCTOPUS PoE Switching current Switching voltage Storage temperature ambient air temperature Humidity Atmospheric pressure OCTOPUS Protection class Protective elements limit the insula tion voltage to 90 V DC 1mA 707 VDC 2 250 V DC max 1 A SELV max 60 V DC or max 30 V AC SELV 40 C to 85 C 0 to 95 non condensing Up to 2000 m 795 hPa higher alti tudes on request Ambient air 40 C to 70 C IP 67 OCTOPUS 8M 16M 24M Release 05 03 10 EMC and immunity EMC interference immunity IEC EN 61000 4 2 Electrostatic discharge Contact discharge 6 kV Air discharge 8 kV IEC EN 61000 4 3 Electromagnetic field 80 2 700 MHz 20 V m IEC EN 61000 4 4 Fast transients burst Power line 4kV Data line 4kV IEC EN 61000 4 5 Voltage surges Power line 1 kV line line Power line 2 kV line earth Data line 1kV IEC EN 61000 4 6 Line conducted interference voltages 10 V 150 kHz 80 MHz EN 61000 4 9 Impulse shaped magnetic fields 300 A m only OCTOPUS Train EMC emitted interference EN 55022 Class A Yes FCC 47 CFR Part 15 Class A Yes German Lloyd Classification Construction Guidelines VI 7 3 Part 1 Yes Ed 2001 Stability Vibration IEC 60068 2 6 Test FC test level according to IEC 61131 2 Y
29. t customized package leaves you free to choose the service components you want to use Internet http www hicomcenter com OCTOPUS 8M 16M 24M Release 05 03 10 31 fh HIRSCHMANN A BELDEN BRAND
30. tware are protected by copyright All rights reserved The copying reproduction translation conversion into any electronic medium or machine scannable form is not permitted either in whole or in part An exception is the preparation of a backup copy of the software for your own use For devices with embedded software the end user license agreement on the en closed CD applies The performance features described here are binding only if they have been expressly agreed when the contract was made This document was produced by Hirschmann Automation and Control GmbH according to the best of the company s knowledge Hirschmann reserves the right to change the contents of this document without prior notice Hirschmann can give no guarantee in respect of the correctness or accuracy of the information in this document Hirschmann can accept no responsibility for damages resulting from the use of the network components or the associated operating software In addition we refer to the conditions of use specified in the license contract You can get the latest version of this manual on the Internet at the Hirschmann product site www hirschmann ac de Printed in Germany Hirschmann Automation and Control GmbH Stuttgarter Str 45 51 72654 Neckartenzlingen Germany Tel 49 1805 141538 039 679 002 05 0310 15 3 10 Content 2 2 2 3 Safety instructions About this manual Legend Device description Description of the device variants 1

Download Pdf Manuals

image

Related Search

Related Contents

ASUS CPX20 User's Manual      Samsung SM-T525 دليل المستخدم  IAN 77603 - Home  UCW Base Separation  Garmin NX300 All in One Printer User Manual  1 明治側条オリゼメートスタークル顆粒水和剤  V ISU ALNE TWORK SOLUTION  ORP Controller Manual  

Copyright © All rights reserved.
DMCA: DMCA_mwitty#outlook.com.