USER MANUAL - Pool Sweden
Contents
1. Supply Voltage V 220 240 220 240 220 240 220 240 220 240 220 240 220 240 Rated Current A 32 4 1 44 6 7 6 7 9 3 9 3 Advised Fuse A 10 10 10 20 20 20 20 WATER DATA Advised pool volume m 0 15 0 15 0 15 25 35 25 35 35 55 35 55 Advised water flux Lmin 70 70 70 100 100 140 140 Water pipe in out spec mm 50 50 50 50 50 50 50 General Data Compressor Rotary Rotary Rotary Rotary Rotary Rotary Rotary Air flow Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Condenser Titanium in PVC Noise level 10m dB A 35 35 35 36 36 37 37 Noise level 1 m dB A 46 46 46 47 47 48 48 Water Pressure Kpa 12 12 12 15 15 15 15 Refrigerant kg 0 6 0 8 0 8 1 1 14 1 3 1 3 Dimension amp Weight Net Dimension mm 750325470 703540 750325470 DIOT 03050 10030620 1000300 Net Weight kg 36 37 37 50 50 65 65 Packing Dimension mm 8345530 85345530 8345530 1060380000 1060380600 1000380000 1060380600 Gross Weight kg 38 42 42 56 56 72 72 i 3 Installation 3 1 Installation illustration Water Treatment Pump Filter Horizontal By Pass Hot Water To Pool NOTE The factory only provides the heat pump unit The other items in the illustration are necessary spare parts for the water system which are provided by users or installers A ATTENTION Please follow these steps when operating the first time 1 Open valve and charge water 2 Make sure that the pump and the water in pipe have been filled with water 3 Close the valv
2. AAZUO POOL HEAT PUMP USER MANUAL 1 Introduction Specifications Installation Initial Startup of the unit Operation Maintenance 1 Introduction Thank you for using AZURO swimming pool heat pump for your pool heating it will heat your pool water and keep the constant temperature when ambient temperature at 5 C to 40 C In order to offer qualified reliable and flexible heat pump unit to our customer please read this manual carefully before installing operating and troubleshooting then process accordingly This manual includes all necessary information A ATTENTION e The heat pump unit must be installed by qualified technicians from after sales center or authorized distributor e Operating and maintaining according to recommended time and frequency on the manual e Use only standard spare parts 2 Specificatio 2 1 Swimming Pool Heat Pump Horizontal Design Models XPO03Hs Capillary XPOSHs EEV XP05Hs Capillary XPO9Hs EEV XP09Hs Capillary XP12Hs EEV XP12Hs Capillary Capacity at 25 C Heat Output KW 3 5 5 5 8 7 8 7 12 12 Power Consumption KW 0 70 0 9 0 9 1 45 1 45 2 0 2 0 COP 5 5 5 5 5 6 6 6 6 Capacity at 15 C Heat Output KW 2 56 3 7 3 7 6 45 6 45 9 0 9 0 Power Consumption KW 0 61 0 89 0 89 1 43 1 43 1 95 1 95 COP 4 4 15 4 15 4 5 4 5 4 6 4 6 Power
3. d a hold for 5 seconds to enter operating parameter setting interface You can check water in water out Condenser ambient temperature 3 Mode can be changed while running 4 When the unit is switched off current time is displayed Time setting Press to set the time and press w or A to adjust the time After pressed the again to store the new data When setting the time and can not work TIMER ON SETTING Press to set the time for HP start to run and press W or A to adjust starting time then to press again to store the new data When re lights Press to cancel the timer setting TIME OFF SETTING Press e set the time for HP stop running press W or 4 to adjust the time of stop running then press againto store the new data When Diignts press Bto cancel the timer setting 5 4 RUNNING DATA SETTING A ATTENTION HP running parameters must be checked after installation and before first used When HP is running LED displays water inlet temperature When HP is stopping LED wire controller displays the actual time When HP running the running mode cooling or heating and water temp could be changed Other parameters only changeable when HP stopping Parameter Meaning Range Default Remarks 0 To set the entering water temp under cooling mode PORO 28 Ad
4. e and start the unit 3 2 Installation 1 The heat pump unit must be installed by professional technicians otherwise unit may be damaged or body injured even dead 2 The unit is designed for outdoor location with good ventilation Recirculation of cold discharge air back into evaporator coil will greatly reduce heating capacity and efficiency of the unit which will void the compressor warranty 3 The unit can be installed almost anywhere in the outdoors To get a good performance it needs to meet the three factors a Good ventilation b Stable and reliable power supply c Recycled water system The difference from gas water heater it should not bring environmental pollution or have the installing problems in windy areas pa 4 The unit should not be installed in a limited air ventilation area or placed in a bush where it will block the airinlet These location deny the unit of a continuous source of fresh air When seasons changing it may stick leaves on the evaporator coil thereby reducing its efficiency and impact of its service life 5 For indoor installation please consult more instruction from technicians 6 When install a bypass it should be not exceed 30 of nominal flow rate 7 Must make Water level higher than the circulation pump location 8 Below picture show the minimum required distance on each side of pool heat pump unit Air inlet Air outlet HA OO Ww A 9 Typically th
5. e pool heat pump unit should be installed aside the pools less than 7 5 meters distance If it is installed farther away the pipeline system will cause greater heat loss The most of pipeline are installed under ground although the pipeline system has to do thermal insulation but tunnels and the soil around will still occur heat exchange for example each 30 meters 15 meters t oand from the pump 30 meters total unless the ground is wet or the water table is high A very rough estimate of heat loss per 30 meters is 0 6KW per hour 2000BTU for every 5 C surrounding the pipe which translates to about 3 to 5 increase in run time 10 To get the best heat exchange of heat pump unit it should be matched the normal rate of water flow recommended in specification sheet 11 Itis required to increase the discharge pipe to prevent freezing in cold season to put T fitting and ball valve to facilitate changing the water in winter or emptying the water out of system to prevent freezing when HP stop operating at the ambient temperature below zero otherwise the unit may be damaged 3 3 The location of chemical s instruction to your system is also critical to the heater s life If an automatic chlorinator or brominates is used it must be located downstream of the heater A trap must be installed between the chlorinator and the heater to prevent chlorine return into the heat pump See below pictures Pressure type Chlorinator or Bro
6. justable 1 To set the entering water temp under heating mode 15 35 C 28 Adjustable 2 Entry into defrosting time period 30 90MIN 40MIN 3 Terms of Entry defrosting function 30 Cto D 7C 4 Terms of Exit defrosting function 2 to 30C 20C 5 Time of Exit defrosting 1 to 12MIN 8MIN ee ee e eiza 7 Mode selection of Electronic expansion valve 0 1 1 auto 8 Superheat for heating target 15 C 15 C 3c 9 Superheat for cooling target 15 C 15 C 10C n Refrigerant compressor output temperature protection 85 110C 100 C o Low ambient temperature protection 10 10 TE A Manual adjustment steps of electronic expansion valve 18 94 70 b Inlet water temperature 9 99 C Exact testing by value c Refrigerant compressor output temperature 9 130 C Exact testing by value d Condenser temperature under heating mode 9 99 C Exact testing by value E Gas return temperature 9 99 C Exact testing by value F Ambient temperature 9 99 C Exact testing by value G Condenser temperature under Cooling mode H Actual steps of electronic expansion valve N 5 Exact testing by value Remarks 1 When HP stop running in 30 seconds water pump will shut off automatically 2 LED wire controller can operate the water pump after connected additional cable to the pump device in the position of PUMP terminal accurately 3 It is necessary to put an extra 3 phase transfer device for 3 phase water pump 6 Maintenance 1 You should check the water supply syste
7. m regularly to avoid the air entering the system and occurrence of low water flow because it would reduce the performance and reliability of HP unit 2 Clean your pools and filtration system regularly to avoid the damage of the unit as a result of the dirty of clogged filter 3 Keep the HP unit dry clean well ventilated and always clean side of the heat exchanger which can maintain a good heat exchange and energy saving 4 Only a qualified service technician is allowed to operate pressure of the refrigeration system 5 Check power cable connection if heat pump starts to operate abnormally you should turn it off and contact with qualified technicians 6 You should discharge the water from water pump and other water system to prevent from the freezing damage in winter seasons 7 You should discharge the water from bottom of water pump if HP unit will stop running for a long time In another way you should check the units thoroughly and fill the system with water fully before the unit start to run again
8. minator In line Chlorinator or Brominator Check valve Chlorinator Chlorinator 4 Initial Startup of the unit Note Please make sure the water pump is running in circulation with adequate rate of water flow Startup Procedure after Installation is completed and please follow these steps 1 Turn on your filter pump check water leaks and verify flow of swimming pool 2 Turn on the electrical power supply to the unit then press the key ON OFF of wire controller it should start in several seconds 3 After running a few minutes make sure the air ventilation from the side top of the unit is cooler Between 5C and 10 C 4 When turn off the filter pump the unit should also turn off automatically if not then adjust the flow switch 5 Allow the unit and pool pump to run 24 hours per day until the water reaches the desired temperature When the temperature reaches the setting value the HP unit will shut down Aben the pool temperature drops more than 1 C pleaserestart as long as HP unitis running Water Flow Switch It is equipped with a flow switch for protecting the HP unit running with adequate water flow rate It will turn on when the pool pump runs and shut it off when the pump shuts off If the pool water level higher than 1 m above or below the heat pump s automatic adjustment knob your dealer may need to adjust its initial startup Time Delay HP unit should be equipped with a 3 minute built in solid s
9. tate re start delay protection Time delay control is an integral part of the circuit control it can eliminate restart cycling and contactor chatter The time delay will automatically restart the HP unit approximately 3 minutes after each control circuit interruption Even a brief power interruption will activate the solid state 3 minute restart delay and prevent the unit from the starting until the 3 minutes countdown is completed 5 Operation 5 1 The functions of LED wire controller LED display Press to adjust the water temperature Operation mode instruction gt ie to turn 0 and turn off the Unit Press to set Timer on Press to set the Time Press to set Timer off 5 2 Howto set operation parameter LED display show real time till HP unit is power off 1 Long press 5 seconds to enter operating parameter setting interface 2 Under parameter setting Press Jand a hold for 5 seconds to enter operating parameter setting interface 3 Under parameter setting Press again to start setting parameters from 0 to A see operation parameter table 4 Leave it 8 seconds LED will display water in temperature under running or time until stops 5 Under current mode press EA or a to modify the water setting temperature whenever it is ON OFF status d 06 Parameter 0 To set the entering water temp under cooling mode 8 35 C default setting 28 C Parame
10. ter 2 Total working time of compressor after frosting 30 90MIN default setting 40MIN Parameter 4 Terms of Exit defrosting function 2 to 30 C default setting 13 C Me Parameter 1 To set the entering water temp under heating mode 15 35 C default setting 28 C Me Parameter 3 Terms of Entry defrosting function 30 C to 0 C default setting 7 C Boole Parameter 5 Time of Exit defrosting 1 to 12MIN default setting 8MIN Me Parameter 6 Parameter 7 Mode 0 Cool 1 Heat and Cool Mode selection of Electronic 2 Heat and cool auxiliary elec expansion valve 0 to 1 Heating 3 Heat i default setting 3 Heat Gefault setting 1 auto Note Parameter 7 is only applied for HP units with Electronic expansion valve Parameter 8 Heating target for superheat 15 C 15 C default setting 3 Parameter 9 Cooling target for superheat 15 C 15 C default setting 2 C ParameterA Manual adjustment steps of electronic expansion valve 18 94 defaulting setting 70 5 Parameter n Refrigerant compressor output protection rotection range 85 C to 110 C range 1062108 default 100 C default 7c m Ev ARZA zi AES zi AES EZE omolo Parameter O Low ambient temperature 1 Long press 5 seconds to enter operating parameter setting interface 2 Press w an