Home
Indoor / Outdoor Thermometer with Ice Alert Model: EW91 USER
Contents
1. SPECIFICATIONS TYPE DESCRIPTION MAIN UNIT 70 x 30 x 109 mm nen 2 76 x 1 18 x 4 29 in Weight 111g Signal frequency 433 MHz Temperature E range 5 C to 50 23 F to 122 F Temperature 0 1 C 0 2 F resolution Ice alert 3 C to 2 C temperature range 37 F to 28 F Power 2 x AAA 1 5V batteries REMOTE UNIT EW 99 58 x 23 x 100 mm 2 28 x 0 9 x 3 94 in Weight 52g LxWxH Signal frequency 433 MHz Number of channel 3 Transmission range 30 m 98 ft unobstructed Temperature range 20 C to 60 C 4 F to 140 F Power 2 x AAA 1 5V batteries Note We recommend that you use alkaline batteries with this product for longer usage and lithium batteries in temperatures below freezing PRECAUTIONS e Do not subject the unit to excessive force shock dust temperature or humidity e Do not cover the ventilation holes with any items such as newspapers curtains etc e Do not immerse the unit in water If you spill liquid over it dry it immediately with a soft lint free cloth e Do not clean the unit with abrasive or corrosive materials e Do nottamper with the unit s internal components This invalidates the warranty e Only use fresh batteries Do not mix new and old batteries e Images shown in this manual may differ from the actual display e When disposing of this product ensure it is collected separately for special treatment and n
2. e Press it once to turn on the backlight for 5 seconds and then press it again to show the minimum and maximum temperature records in the past 24 hours e Press and hold it for 3 seconds to delete the minimum and maximum temperature records 5 C F slide switch e Slide it to switch between Celsius and Fahrenheit 6 SENSOR key e Press it once to search a sensor e During the reception period press and hold it for 3 seconds to stop the reception 7 RESET key e Press it to return all values to default values e In case of malfunction the unit may be required to reset 8 BATTERY COMPARTMENT e Accommodates 2 AAA size batteries 9 BATTERY DOOR LCD DISPLAY i 1 Signal indicator Lc n nmm mn j 2 Channel a J 3 Outdoor temperature 4 pim itt E Es 6 4 Low battery indicator j 5 Min and Max temperature 5 UN iit ii i 5 6 8 F alij 7 Indoor temperature eee ee REMOTE SENSOR a 4 L 1 LED indicator e Flashes when the remote unit sensor a reading 2 Wall mounting holder e Supports the sensor on the wall 3 RESET key e Press it to restart the sensor and return all values to default values 4 CHANNEL slide switch e Assign the sensor to channel 1 2 or 3 5 BATTERY COMPARTMENT e Accommodates 2 AAA size batteries 6 BATTERY DOOR RECEPTION OF SENSOR SIGNAL OPERATING THE TEM
3. 7062 USA Declare that the product Product No EW91 Product Name Indoor Outdoor Thermometer with Ice Alert Manufacturer IPM Concepts Limited Address Block C 9 F Kaiser Estate Phase 1 41 Man Yue St Hung Hom Kowloon Hong Kong Telephone No 1 800 853 8883 is in conformity with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference 2 This device must accept any interference received including interference that may cause undesired operation 2009 Oregon Scientific All rights reserved
4. C8311A Size A4 OreGcon SCIENTIFIC Indoor Outdoor Thermometer with Ice Alert Model EW91 USER MANUAL Thank you for your purchase of this Indoor Outdoor Thermometer Please read these instructions carefully and keep the manual well for future reference The receiver unit has a clear display that shows the indoor temperature the maximum amp minimum temperature records in the past 24 hours as well as the outdoor temperature measured and transmitted from the remote sensors It is able to receive and display readings from up to 3 remote sensors The 433 MHz technology means no wire installation is required and you can place the sensor within 30m 100ft from the main indoor unit OVERVIEW RECEIVER 2 _ recon L 1 LCD display e Displays the outdoor and indoor temperature records the current channel and the low battery indicator 2 lce Alert indicator light e Flashes when the outdoor temperature is between 2 0 C 28 F and 3 0 C 37 F 3 CHANNEL key e Press it once to turn on the backlight for 5 seconds and press it again to switch among Channel 1 2 and 3 e Press it once to turn on the backlight for 5 seconds and then press and hold it for 2 seconds to view the channels automatically e When the channels are being shown automatically press it to exit the automatic display mode 4 MIN MAX key
5. PERATURE STATION 1 Remove the battery door and insert 2 new AAA size batteries as per the polarity information marked on the battery compartment Press RESET key to restart the main unit Slide C F switch to select between C and F Slide the battery door back on Press CHANNEL key to select the desired channel ag Main unit is searching for the sensor s Li Lh the icon will be flashing oo E The sensor s cannot be found Sensor 1 has been found E the icon will be displayed but won t flash and E Outdoor The sensor s cannot be found after temperature operating the main unit for 15 minutes Area Note When the sensor signal is received the icon y will be displayed on the LCD OPERATING THE SENSOR 1 Remove the battery door and slide the CHANNEL switch to CH 1 When using additional sensors make sure each sensor is assigned a different CHANNEL number 2 Ilnsert 2 new AAA batteries matching polarities 3 Press the RESET key 4 Slide the battery door back on Note e Place the sensor in location away from direct sunlight and rain Do not place the sensor more than 30 m 100 ft from the main indoor unit Position the sensor so that it faces the main indoor unit minimizing obstructions such as doors walls and furniture Place the sensor in a location with a clear view to the sky
6. away from metallic or electronic objects Position the sensor closer to the main unit during cold winter months as below freezing temperatures may affect battery performance and signal transmission Tip the transmission range may vary depending on many factors You may need to experiment with various locations to get the best results Standard Alkaline batteries contain significant amounts of water Because of this they will freeze in low temperatures of approximately 12 C 10 F Disposable Lithium batteries have a much lower threshold for temperature with an estimated freezing range of below 30 C 22 F Wireless ranges can be impacted by a variety of factors such as extremely cold temperatures Extreme cold may temporarily reduce the effective range between the sensor and the base station If the unit s performance fails due to low temperature the unit will resume proper functioning as the temperature rises to within the normal temperature range i e no permanent damage will occur to the unit due to low temperatures USING THE BACKLIGHT FUNCTION In normal mode press CHANNEL or MIN MAX key once to activate the backlight for 5 seconds SWITCHING BETWEEN C amp F TEMPERATURE FORMATS Slide 2C 2F switch to select between Celsius and Fahrenheit VIEWING THE MINIMUM AND MAXIMUM TEMPERATURE RECORDS In normal mode press MIN MAX key twice to show the minimum indoor amp outd
7. he party responsible for compliance could void the user s authority to operate the equipment Note This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures e Reorient or relocate the receiving antenna e Increase the separation between the equipment and receiver e Connect the equipment into an outlet on a circuit different from that to which the receiver is connected e Consult the dealer or an experienced radio TV technician for help DECLARATION OF CONFORMITY The following information is not to be used as contact for support or sales Please visit our website at www2 oregonscientific com service support for all inquiries We Name Oregon Scientific Inc Address 19861 SW 95th AVe Tualatin Oregon 9
8. oor temperature records in the past 24 hours 2 Press it again to show the maximum temperature records 3 Press it again to exit Note Press and hold it for 3 seconds to delete the minimum and maximum temperature records MAX temperature records MIN temperature records D Se eee 2 Sy n oe 7 or fae i ot fo ri ii we i De m ml Tj IN mi Ta j N i 2 ne ii j nan Em i SEE EN s e MIN SES See USING ICE ALERT FUNCTION If the outdoor temperature range is 2 0 C 3 0 C 28 F 37 F the Ice Alert indicator light will be turned on and flash BATTERY REPLACEMENT If the low battery indicator m displays beside the outdoor temperature it means that the battery power of sensor is not enough and you should replace with 2 AAA size batteries at once While if the low battery indicator gm displays beside the indoor temperature it indicates that you should replace batteries of the main unit with 2 new AAA size batteries Low battery indicator E9 Am Be i OUT Lt ca E BEE IN EEE EEE i ca Note Attention Please dispose of the used unit or batteries in an ecologically safe me PLACEMENT OF MAIN UNIT AND SENSOR For the sensor place the screw on the desired wall and hang the sensor by the recessed hole in the back of it or simply place it on the desktop For the main unit you can just place it on the table by itself re
9. ot as normal household waste e Placement of this product on certain types of wood may result in damage to its finish for which Oregon Scientific will not be responsible Consult the furniture manufacturer s care instructions for information e The contents of this manual may not be reproduced without the permission of the manufacturer e Do not dispose old batteries as unsorted municipal waste Collection of such waste separately for special treatment is necessary e Please note that some units are equipped with a battery safety strip Remove the strip from the battery compartment before first use Note The technical specifications for this product and the contents of the user manual are subject to change without notice ABOUT OREGON SCIENTIFIC Visit our website www oregonscientific com to learn more about Oregon Scientific products If you re in the US and would like to contact our Customer Care department directly please visit www2 oregonscientific com service support For international inquiries please visit wwwe2 oregonscientific com about international FCC STATEMENT This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation WARNING Changes or modifications to this unit not expressly approved by t
Download Pdf Manuals
Related Search
Related Contents
製品安全データシート Starrsed Inversa Gebrauchsanweisung Dis-moi quelque chose Aide-mémoire en cas de dégâts de tempète STIHL KM 56 R Product Instruction Manual Equip USB 2.0 Hub 7 Port HOBLink JWT User Manual Reason Essentials 8.1 Installation Manual Copyright © All rights reserved.
Failed to retrieve file