Home

H017-001-028-6 English PAD TRAINER User Manual.cdr

image

Contents

1. HeartSine samaritan PAD Trainer user manual TABLE OF CONTENT HeartSine samaritan PAD Trainer HeartSine samaritan PAD Trainer Accessories Setup and Programming Installing the HeartSine samaritan PAD Trainer PAK Turning the HeartSine samaritan PAD Trainer on and off Cleaning Choosing scenarios Changing the volume Choosing language Using the Trainer Pads Charging the PAD Trainer Product list ARR WWW N OD on HeartSine samaritan PAD CONFIGURATION HeartSine Technologies can provide you with a fully configurable HeartSine samaritan PAD system to allow you to comply with your chosen Sudden Cardiac Arrest SCA treatment protocol Our current devices can be configured to be compliant with the 2000 or 2005 version of the AHA ERC guidelines on Cardiopulmonary Resuscitation CPR and Emergency Cardiovascular Care ECC You should have been trained in the appropriate version of the AHA ERC guidelines and the use of your device configuration Contact HeartSine Technologies or your authorised HeartSine Technologies distributor for further information AHA ERC 2000 AHA ERC 2005 Configuration ABOUT THIS EDITION Information in this document is subject to change without notice and does not represent a commitment on behalf of HeartSine Technologies No part of this manual may be reproduced or transmitted in any form or by any means electrical or mechanical including photocopying and recording for any purpose
2. cables when re inserting the Trainer Pad tray lid Contact your local HeartSine Technologies distributor for replacement Trainer Pads when required www heartsine com When to recharge The removable HeartSine samaritan PAD Trainer Pad Pak contains a rechargeable battery It is recommended that you ensure the HeartSine samaritan PAD Trainer Pad Pak is fully charged prior to any training activities When fully charged the HeartSine samaritan PAD Trainer will give you approximately 6 hours of usage before it needs to be recharged The HeartSine samaritan PAD Trainer will monitor the capacity of the battery as it approaches depletion the Trainer will play the following message Warning Low battery If this warning is heard you may continue to use your HeartSine samaritan PAD Trainer for a limited period of time If the trainer becomes completely depleted of power it will shut itself down At this point the Trainer Pad Pak must be recharged in order to continue using the device Extended operation between charges For extended use of the HeartSine samaritan PAD Trainer the device can be used with its charger attached This will allow the HeartSine samaritan PAD Trainer to operate longer than 6 hours between recharging To use the HeartSine samaritan PAD Trainer while attached to the mains electricity supply simply connect it to the charger as per the instructions contained in the Charging Process The HeartSine
3. samaritan PAD Trainer will charge as you are using it If it is necessary to provide extended periods of training where connection mains electricity is not possible HeartSine Technologies recommend you purchase a second Trainer Pad Pak for your device this will allow you to remove the depleted Trainer Pad Pak and replace it with a second charged Trainer Pad Pak If you require a second Trainer Pad Pak contact your HeartSine Technologies authorised distributor There are no user serviceable parts inside your HeartSine samaritan PAD Trainer Trainer Pad Pak or charger These products should not be opened In the unlikely event of a malfunction please contact your distributor immediately PAD TRAINER Charging Process The HeartSine samaritan PAD Trainer Pad Pak contains a rechargeable battery It is recommended that you ensure the HeartSine samaritan PAD Trainer Pad Pak is fully charged prior to training activities To safely recharge the HeartSine samaritan PAD Trainer follow the instructions given below u Insert the charger adaptor into the socket on the Trainer Pad Pak as shown in the picture Ensure the adaptor is fully inserted Plug the charger into the mains electricity supply Where required an adaptor will have been provided with your charger lf necessary use the adaptor to plug the charger into your mains supply Check that the red light on the charger is on This light indicates that the Trai
4. will now default to the selected volume Changing the Language 1 Press and hold the Pause Button At the same time press the On Off Button Keep the Pause Button pressed until you hear Setup Mode 2 Press the Pause Button to change the language The trainer will say Call for medical assistance in the languages programmed in the device from our language library For a list of available languages contact HeartSine Technologies 3 Press the Pause Button again to change the language If the pause button is not pressed to change the language within 10 seconds the HeartSine samaritan PAD trainer will repeat the message in the current language 3 times and shut down When the desired language is selected do not press any buttons The trainer will repeat the message three times emit 3 short beeps and shut down If the trainer is turned on after the above is carried out it will deliver voice prompts in the selected language Using the Trainer PADs The Trainer Pads are located inside the Trainer Pad tray Pull the green tab on the Trainer Pad tray lid and remove The Pads can then be peeled from their liner and placed on a mannequin as indicated on the electrode The Trainer Pads are designed to be a single use component They can be replaced by disconnecting from the connector on the Pad When replaced the Trainer Pads can be returned to the Trainer Pad Tray Take care not to crush the Trainer Pads or
5. without the express written permission of HeartSine Technologies Copyright 2008 HeartSine Technologies All rights reserved samaritan is a registered trademark of HeartSine Technologies Saver and SCOPE are trademarks of HeartSine Technologies All other trademarks and registered trademarks are the property of their respective owners www heartsine com Heartsine samaritan PAD Trainer Training Scenarios Available 2005 Guidelines Scenarios Scenario one No pads attached Shock advised Two minutes CPR Scenario two No pads attached No shock advised Two minutes CPR Scenario three No pads attached Check pads Shock advised Scenario four Shock advised Two minute CPR pause Shock advised Two minute CPR pause No shock advised The HeartSine samaritan PAD trainer and Trainer Pad Pak have a warranty period of two years from the date of purchase of the device R i i 2000 Guidelines Scenarios HeartSine samaritan PAD Trainer Accessories Scenario five No pads attached Shock advised x3 One minute CPR Shock advised No shock advised One minute CPR Scenario six No pads attached Check pads The trainer package includes One set of HeartSine samaritan PAD Trainer Pads accessed by removing tray lid Trainer Charger with adaptor The trainer charger will where necessary be supplied with an adaptor Shock advised x2 to allow connection to your electricity No shoc
6. ar setup mode ay f f Ss 4 ig T 2 Press the shock button to scroll through the scenarios available see Training Scenarios Available section The system will announce Training Scenario and then the number of the current scenario 3 Within 10 seconds press the Shock Button again to change the scenario If the Shock Button is not pressed to change the scenario then the HeartSine samaritan PAD Trainer will repeat the previously selected scenario number several times and shut down gt When the required scenario number is selected do not press any other buttons The scenario number will be repeated a number of times and the trainer will emit 3 short beeps and shut down If the trainer is now turned on it will play the selected scenario PAD TRAINER Changing The Volume 1 Press and hold the Shock Button Atthe same time press and release the On Off button Keep the shock button pressed until you hear setup mode 2 Press the Pause Button to change the volume level of the device The HeartSine samaritan PAD Trainer will emit a beep and you will hear a number 1 4 which is the currently selected volume level ia oD 3 Press the Pause Button again to change the volume level ia gt gt When the desired volume is selected do not press any other buttons The trainer will repeat the number of the volume three times then emit 3 short beeps and shut down The HeartSine samaritan PAD Trainer
7. k advised mains supply One minute CPR Scenario seven Shock advised The Different Training Scenarios No Shock advised One minute CPR The HeartSine samaritan PAD trainer has 8 training scenarios Scenario eight No pads attached to choose from Scenarios 1 to 4 are based on AHA ERC 2005 Shock advised guidelines and scenarios 5 to 8 are based on AHA ERC 2000 No Shock advised guidelines One minute CPR pause Listed opposite are the scenarios available and a brief outline of Shock advised how the training incident will unfold for those using the One minute CPR pause HeartSine samaritan PAD Trainer No shock advised PAD TRAINER 3 Setting the HeartSine samaritan PAD Trainer Installing Turning The HeartSine samaritan PAD Trainer On and Off Ensure that the trainer Pad Pak is fully charged see Charging section of this Turn on the HeartSine samaritan PAD Trainer by pressing the manual Place the HeartSine On Off button By default the Trainer will function in the last samaritan PAD Trainer and the scenario setting used trainer Pad Pak on a flat surface Push the trainer Pad Pak into the opening of 4 the HeartSine samaritan PAD Trainer of the and listen for a click sound to ensure that it is properly inserted the Trainer Pad Pak Press the On Off Button and listen to the voice prompts to ensure that the unit is functioning Turn off the HeartSine samaritan PAD Trainer by pressing the On Off Butto
8. n again To change the scenario played the language gt spoken or the volume level of the HeartSine Ss samaritan PAD Trainer follow the instructions on Pressing the Pause Button when a scenario is playing will stop he following pages the scenario An LED will illuminate to show that the pause function is active Pressing the Pause Button again will cause the Cleaning the HeartSine samaritan PAD Trainer same scenario to resume and the LED will go off You may clean your HeartSine samaritan PAD Trainer with a soft cloth that has been dampened by one of the following Soapy Water Isopropyl Alcohol 70 solution Do not immerse any part of the HeartSine samaritan A PAD Trainer in water or any type of fluid Contact with fluids may seriously damage the device or cause fire or shock hazard If the HeartSine samaritan PAD Trainer has insufficient charge it will not function correctly Plug charger into the system to recharge the system For full instructions see the Charging section of this manual You may continue to operate the HeartSine samaritan PAD Trainer as it recharges Do not clean the HeartSine samaritan HeartSine samaritan PAD Trainer with abrasive materials or solvents 4 www heartsine com Setting the HeartSine samaritan PAD Trainer Choosing Scenarios 1 Press and hold the Shock Button At the same time press and release the On Off Button Keep the Shock Button pressed until you he
9. ner Pad Pak is charging Leave the Trainer Pad Pak to charge To fully charge a completely depleted Trainer Pad Pak will take approximately 12 hours Remove the adaptor from the Trainer Pad Pak Unplug the charger and store it away Turn on the trainer to ensure that the device is working The HeartSine samaritan PAD Trainer is now ready to assist in the provision of defibrillation training The HeartSine samaritan PAD Trainer must only be charged with the charger supplied with it Use of any other charging device will nullify the warranty and may result in damage to the HeartSine samaritan PAD Trainer The HeartSine samaritan PAD Trainer and charger are A designed for indoor use only Do not use in wet or damp environments HeartSine Technologies PRODUCT LIST SELECTION TRAINING SYSTEMS TRN SYS XX 05 HeartSine samaritan PAD Training System AHA ERC 2000 2005 Guidelines TRN ACC 01 HeartSine samaritan PAD Trainer Battery Charger TRN ACC 02 HeartSine samaritan PAD Trainer Training electrodes Set of 10 FOR FURTHER INFORMATION PLEASE CONTACT AN AUTHORISED HEARTSINE TECHNOLOGIES DISTRIBUTOR Worldwide Headquarters Manufactured by HeartSine Technologies Inc HeartSine Technologies Ltd 105 Terry Drive Canberra House Newtown 203 Airport Road West PA 18940 USA Belfast BT3 9ED Northern Ireland Tel 1 215 860 8100 Tel 44 0 28 9093 9400 Fax 1 215 860 8118 Fax 44 0 28 9093 9401