Home
User manual - Thermocold
Contents
1. User manual Thermocold THE AIRVOLUTION User manual Modular hydronic groups with scroll compressors MUPCO1UEL_REV00_0812_UK Pagina 1 di 11 Thermocold THE AIRVOLUTION User manual INDEX 1 1 Advanced SlISCIONIG ccic cincicreinsstoeciontnestwiecle armenia eee dine emcee 3 M2 User terminal waiewencasncscamnsiesautteiagenatedeetineinpeibarimentnelese boise E E eiap esas 3 1 3 PLD GENIUS Terminal Management siiccccisacccssccticcerecatecssasiciereessmesvansseeererareearesueencratweuree 4 1 3 1 Unit power OR Of csiicssvicciesicxessesiventiderccsaierrviassdsrsieasernyes didsecaandeunvaa dds siesdanayeedderseandaaats 5 12 UN POWSl ON OIL www uinsnieenais iene nies iets 5 1 3 3 Circ it powert OM Offresi a E E E 5 1 3 4 How to navigate through the screens of the PLD display cceeeceeeeeeeeeeeeeeeeeee 5 1 3 5 Language selection by GENIUS terminal cccccceeeeeeeeeseceeeee eee eeeeneeseeeeeeeeeeeeeeaee 9 1 3 6 Machine operation parameters branch ccccceccceeeeceeee eter ee eeeeeeneeeeeeeeeeeteeeetaeeeeeeees 10 1 3 7 User BPANG ixecucscniasetaveeavncavteatecacctaveestneduetaevearecaxntatedgeVeateesceratedaweanecareiatedgearecaceratetas 10 1 3 8 Alarm table Srcpiaxscanuiacdtaasiachihaniaxdaganiavscanniaxdasaniacinnsiandigiiachaassiexdaganiacsiaasiandiatiactianwiaas 11 MUPCO1UEL_REV00_0812_UK Pagina 2 di 11 Thermocold THE AIRVOLUTION User manual 1 1 Advanced electronic Electronics tec
2. AL041 MAC1 COMPRESSOR 1 MAINTENANCE AL042 MAC2 COMPRESSOR 2 MAINTENANCE AL050 U1AL UNIT 1 OFF LINE AL051 U2AL UNIT 2 OFF LINE AL052 U3AL UNIT 3 OFF LINE AL053 U4AL UNIT 4 OFF LINE AL055 CLAL CLOCK CARD FAILURE AL056 DIAL DRIVER 1 CIRCUIT 1 OFFLINE AL057 D2AL DRIVER 2 CIRCUIT 1 OFFLINE AL101 PRAL DRIVER 1 PROBE ERROR AL102 EEAL EEPROM ERROR AL104 BAAL BATTERY ERROR AL105 MOPA HIGH EVAPORATION PRESSURE MOP AL106 LOPA LOW EVAPORATION PRESSURE LOP AL107 SKAL LOW SUPER HEAT AL108 VAAL VALVENOT CLOSED DURING SHUT DOWN AL109 SUAL HIGH SUCTION TEMPERATURE MUPCO1UEL_REV00_0812_UK Pagina 11 di 11
3. of the PLD display e Displaying masks of a branch Navigating through the masks of a branch is made by pressing the DOWN ARROW that allows to scroll through the masks in the art from top to bottom and MUPCO1UEL_REV00_0812_UK Pagina 5 di 11 THE ATRUOLUTION User manual and with the UP ARROW key that shows the same masks in reverse order Note On the up arrow button there is also a led with pump symbol instead the down arrow key led is the compressor symbol These leds light up at pump and or compressor start up e Navigation between the different branches The SEL button allows you to move between the different branches except the constructor branch in which you can enter with a password from a user mask In particular a continued pressure maintains active a loop that displays in succession head masks of each branch in the following order BRANCH HEAD MASK Machine operation parameters branch parameter value tin User branch set1 text I O displaying branch d101 text To enter one of the branches the Sel button must be released as soon as the head mask displays the desired branch If you want to enter in manufacturer branch you must first enter into the user branch in the in the way explained above and with the ARROW DOWN you must bring the form that displays the PASS text At this point you must enter the password equal to 66 according to that are the terms of inclusio
4. V00_0812_UK Pagina 7 di 11 THE ATRVOLUTION User manual e Other features ON OFF key allows the switching on and off of the unit and it is equipped with corresponding LED SUN key allows you to select the chiller mode and it is equipped with corresponding LED SNOW key allows you to select the heat pump mode and it is equipped with corresponding LED MUPCO1UEL_REV00_0812_UK Pagina 8 di 11 Thermocold User manual THE AIRVOLUTION 1 3 5 LANGUAGE SELECTION by Genius terminal At the start up unit by default displays a form where you can choose the language to use This screen remains active for 30 seconds after which the program jump automatically to the main menu mask MO You can disable this feature to do this simply 1 Go to the Program branch mask PO 2 Set the correct password 3 Go to the Various Parameters subsector 4 Press the down arrow until you get to the mask with reference R9 5 Select N under Display Form language In any case you can change the language any time To do this just to go in the A2 mask of the key MAINT MUPCO1UEL_REV00_0812_UK Pagina 9 di 11 Thermocold THE AIRVOLUTION User manual 1 3 6 Machine operation parameters branch This is the branch called at the machine startup and it displays the default T evaporator inlet MACHINE OPERATION PARAMETERS Parameter Value Description Tin T Displays the value of B5 Tout T Displays the val
5. ection to all units of the network with the mechanism described above is possible not only by the Master but by the generic unit to which the PGD the dip switch set to 16 always is connected physically MUPCO1UEL_REV00_0812_UK Pagina 4 di 11 THE AIRVOLUTION User manual 1 3 1 Unit power on off There are two ways of powering on off of the unit Q Power on off of the system all the modules Q Power on off of the circuit the single unit The control of the machine state you can do by keyboard digital input enabled supervisor enabled The operation on off using the ON OFF button of the keypad has the highter priority The machine will be able be switched on off by a supervisor and or by a digital input only if it has been activated before by the keypad 1 3 2 System power on off The control is performed by the master board if it is on you can also turn on all the slave system components on the opposite if it is off 1 3 3 Circuit power on off The control is performed by each slave board the supervisor will able to switch on off individual slave boards only if the master is on At the first start up of the system you need to ensure that all boards are powered on querying them through the shared terminal To do this we suggest you to refer to the USER Terminal paragraph which describes the meaning of the different buttons and LEDs on used keyboard 1 3 4 How to navigate through the screens
6. hnologically advanced thanks to the choice of a reliable ise be able to control the parameters of the own thermohygrometric i Te uuu components which complexity remains unknown to the user who will r 1 SHA welfare only by the graphic terminal of simple and immediate use Within the controller have been implemented new features developed specifically by Thermocold for the residential sector and to simplify operations of selection the user interface The pleasant graphic display mounted on the front of the unit allows to change easily the parameters of the system and ensure the thermohygrometric welfare conditions within the building envelope 1 2 User terminal The user terminal can display the operating conditions of the unit at any time and to change parameters MUPCO1UEL_REV00O_0812_UK Pagina 3 di 11 THE AIRVOLUTION User manual 1 3 PLD GENIUS Terminal Management The Master unit can operate both with the PLD that with the GENIUS terminal when you connect physically the GENIUS terminal to the Master PLD remains frozen until the GENIUS terminal is not disconnected this only works for the network configuration for the single machine instead you need to power down and power back Genius Terminal By GENIUS terminal you can be connected to any device on the network by calling using the Info button the mask m_switch_unt_M3 and entering net_address of the unit of interest to connect to any slave unit is
7. n of any of the parameters described in the following paragraph MUPCO1UEL_REV00_0812_UK Pagina 6 di 11 THE ATRUOLUTION User manual e Insert parameters value Parameter inclusion principle provides that from a form which displays the parameter identifier text you enter into the set mask of the same parameter by pressing the PRG button Pressing the PRG key you get the prompt for the parameter change and the last digit to the right of the field to be changed flashes After changing the parameter value with the ARROW UP and ARROW DOWN you must press the PRG button again to confirm the new parameter value N B With a pulse pressure of the SEL button you can return to the display screen of Tin from any identification parameter mask not set in which you are e Alarm reset The occurrence of an alarm event that shows itself with the activation of PLD buzzer and at the same time with the displaying of the text mask containing the alphanumeric alarm code The first pressure of the BELL button silences the buzzer and displays the alarm code mask while with a second pressure of the same button you will reset if the alarm cause has been removed All the possible alarm codes are reported at Alarm table paragraph Note To leave the alarm mask if you are not able to reset because you have not removed the cause you can use the SEL key see above how to navigate among the different branches MUPCO1UEL_RE
8. simply pressing the enter key after setting the field which appears to the right of the string Displays the unit the net_address the only exception is the return on the Master unit that requires pressing the menu key after the enter button N B The connection to all units of the network with the mechanism described above is possible not only from the master but from the generic unit to which the GENIUS terminal always with address on dip switch set on 16 is connected physically The monitoring of the network by the mask m_switch_unt_M3 will no longer be usable if you were to check the fault in this case failure means that the unit is no longer seen on the network of one or more slave units Infact when you have the disappeared of a slave unit from the network the GENIUS terminal connects to the Master unit from whatever the unit to which it was linked to the occurrence of failure and from this time until the drive in failure is resetted it is not longer able to connect to any of the slave units In this situation you can still monitor the single slave terminal by GENIUS terminal connecting physically the GENIUS terminal to the unit of interest after setting the addresses dip switches of the PGD to i 16 where i is the net address of the device that you want to connect The foregoing means that for ex to connect a terminal PGD to the card 2 it must set to its dip switch the value 18 to the card 3 the value 19 and so on N B The conn
9. ue of B6 AI01 Displays the value of B1 AI02 Displays the value of B2 AI03 Displays the value of B3 AI04 Displays the value of B4 CLh Adjust the hours of the clock CL m Adjust the minutes of the clock 1 3 7 User Branch The user branch has the following three masks Parameter Description SET1 SUMMER SET SET2 WINTER SET PASS Construction Password which are the selection masks of the summer and winter SET POINT more manufacturer password mask MUPCO1UEL_REV00_0812_UK Pagina 10 di 11 THE AIRVOLUTION User manual 1 3 8 Alarm table All the possible codes are reported below Note The alarms present on the PGD terminal and not contained in this table will in any case be managed and viewed with their numerical code e g alarm ALO36 will show 36 Parameter Value Description ALOO1 MAL GENERAL SERIOUS ALARM AL002 FRAL ANTI FREEZE ALARM AL003 PAL EVAPORATOR PUMP CUT OUT ALOOS FLAL EVAPORATOR FLOWMETER ALO007 TFAL MAIN FAN CUT OUT ALO10 LPAL LOW PRESSURE PRESSURE SWITCH AL012 HPAL HIGH PRESSURE PRESSURE SWITCH ALO16 TCAL COMPRESSOR CUT OUT ALO17 TCAL COMPRESSOR CUT OUT AL023 TRAL HIGH PRESSURE FROM TRANSDUCER AL030 BIAL PROBE B1 FAILURE OR NOT CONNECTED AL031 B2AL PROBE B2 FAILURE OR NOT CONNECTED AL032 B3AL PROBE B3 FAILURE OR NOT CONNECTED AL033 B4AL PROBE B4 FAILURE OR NOT CONNECTED AL034 B5AL PROBE B5 FAILURE OR NOT CONNECTED AL035 B3AL PROBE B6 FAILURE OR NOT CONNECTED AL040 MAFP PUMP FAN MAINTENANCE