Home

User's Manual - ThermoWorks.com

image

Contents

1. on back About Thermo Recorder TR 71U 72U Outline TR 71U TR 72U Thermo Recorders are data loggers capable of measuring displaying and recording temperature and humidity data TR 71U has two temperature channels and TR 72U has one temperature and one humidity channel The data recorded into the TR 71U TR 72U units can then be downloaded quickly via USB cable to your computer whereby with our exclusive software you can easily process the data into graphs tables save to files and or print it out Moreover it is possible to connect more than one unit at the same time Basic Functions Temperature Measuring Range 60 to 155 C TR 71U The TR 71U with the sensor included in this package can measure and record in a range of 40 to 110 C but by purchasing one of our optional sensors it is possible to measure and record in the wider range of 60 to 155 C Please take a look at our full range of optional sensors to find one to match your application Humidity Measuring Range 10 to 95 RH TR 72U The TR 72U with the sensor included in this package can simultaneously measure and record temperature in a range of O to 50 C and humidity in a range of 10 to 95 RH Data Recording Capacity 8000 readings X 2 channels One channel can record and hold up to 8000 measurement readings If set at a recording interval of 1 hour a unit can continuously record for about one year 1 Year of Operation with just 1 AA Alkaline Batter
2. The temperature humidity sensor should probably be changed after a period of about one year After removing the sensor from its package please change the temperature humidity sensor after one year s usage During use the temperature humidity sensor will accumulate impurities dirt on the surface of the sensor causing the sensor s accuracy and sensitivity to decrease If the sensor is being used in a bad environment smoky or dusty places it may be necessary to change the sensor sooner When the temperature humidity sensor is not being used please place it in the attached vinyl bag with the drying agent included and store it in a cool dark place with a temperature of between 5 to 25 C and a humidity of below 30 RH Attached to the temperature humidity sensor are two stickers a wetness detection sticker and a temperature detection sticker If either of the stickers shows abnormality you should change the old sensor to a new one immediately Wetness Detection Sticker Temperature Detection Sticker Wetness Detection Sticker Informs you that the sensor has been wet Normal Abnormal Under normal conditions black Under abnormal conditions it dots will appear on a white will turn to red background Temperature Detection Sticker Informs you that the sensor measured a temperature measurement over 60 C Normal Abnormal Under normal conditions the Under abnormal conditions the number 601 will lightly appea
3. Included screws X 2 75 double sided tape x 1 aan Compatible Devices TR 71U 72U u D A O O For product information or questions contact us at T amp D corPoRATION 5652 169 Sasaga Matsumoto City Nagano 399 0033 Japan Tel 81 263 27 2131 Fax 81 263 26 4281 E mail overseas tandd co jp Office Hours Monday to Friday 9 00 12 00 13 00 17 00 GMT 9 00 Tokyo Time Home Page We have opened an English Homepage called T amp D Online for your convenience Here you can find information about our company news products upcoming events software and user s guides downloads as well as other support Please stop by and see what we have to offer http www tandd jp Thermo Recorder TR 71U TR 72U User s Manual Published by T amp D CORPORATION Copyright 2004 T amp D Corporation All rights reserved il raul This is printed on 100 recycled paper
4. System Restore Automatic Upda ll Remote General Computer Name Hardware Advanced Add Hardware Wizard The Add Hardware Wizard helps you install hardware Add Hardware Wizard Device Manager a The Device Manager lists all the hardware devices installed on your computer Use the Device Manager to change the properties of any device Driver Signing Device Manager button 3 In the Device Manager Window check to see if USB Recorder 1 is listed under USB Recorder COM Device Manager Device Manager File Action View Help gt 8B H IDE ATA ATAPI controllers Ye Keyboards 4 gt Mice and other pointing devices Monitors B Network adapters Y Ports COM amp LPT SB Processors Sound video and game controllers System devices USB Recorder1 E USB Recorder Com amp USB Recorder1 11 For Windows 2000 1 Turn on your computer and open Windows 2 After Windows has been completely started up connect the supplied USB cable to a USB port on your computer 3 Insert the attached CD ROM in the CR ROM drive If the Installation Window opens close it 4 By connecting a data logger to the USB cable already connected to your computer the Found New Hardware Wizard will automatically open 5 By clicking the Next button a window will open where you can choose how you wish to find the driver file Found New Hardwa
5. This may cause electrocution or other damage including malfunction Areas exposed to excessive vibration This may cause injury malfunction damage or loss of proper electrical contact Areas near fire or exposed to excessive heat This may cause damage including malfunction and deformation Areas prone to smoke dust and dirt This may cause damage including malfunction vi vii Cautions about using the Sensors Cautions about using the temperature sensor TR 0106 The possible temperature measurement range for this sensor is 40 to 110 C Please use it within this range It is possible to use just one extension cable per temperature sensor Cautions about using the temperature humidity sensor TR 3100 The sensor can measure temperature within the range of 0 to 50 C and humidity within the range of 10 to 95 RH Only use the sensor within these ranges If extremely severe temperature changes occur the humidity measurements may appear abnormal Once the sensor s temperature becomes stable the measurements will return to normal This sensor is not waterproof Do not get wet The temperature humidity sensor cable cannot be extended When measuring with the temperature humidity sensor in an environment of 0 to 50 C and less than 30 RH the measurements may sometimes fluctuate This is not abnormal See gt Oo bie A Cautions about using the Sensors Handling the temperature humidity sensor
6. saved recorded data 3 If the battery is further left unchanged the display will automatically shut off If all battery power is lost all data will be lost as well Note If a unit is left without a battery for more than 2 minutes all data will be lost so please work quickly when changing the battery Turning on the Power 1 By holding in the POWER switch at the left side the unit will turn on POWER Switch Turning OFF the Power By holding in the POWER switch the unit will turn off During recording the power cannot be turned off Please stop recording first and then turn off the power Even if the power has been turned off the recorded data will be saved However if the battery power is totally lost all data will be lost so please download data as soon as possible to avoid losing any necessary data Installing the USB Device Driver You will need to install this driver in order to use the device with a USB cable and Windows It is necessary for communication via USB between your computer and any TR 71U 72U device After installing your computer will be able to detect and recognize TR 71U 72U devices that have been connected with a USB cable To the Computer To the Main Unit When installing the software T amp D Recorder for Windows the USB Device Driver will also be copied to your hard disc So even if you do not have the CD ROM but have already installed T amp D Rec
7. equipment You are cautioned that changes or modifications not expressly approved by party responsible for compliance could void your authority to operate the equipment Safety Precautions and Instructions To ensure safety be sure to obey all of the following warnings The following items should be strictly obeyed for the safe usage of this unit and for protecting yourself and other people from bodily harm and or damage to property To ensure the proper use of our product please read the following carefully and fully understand the contents E Explanation of Symbols Explanation of Warning Symbols A These entries are actions that absolutely under no circumstance should be taken The taking of such an action DANGER may cause serious personal physical damage or death AN These entries are actions that if taken may lead to physical injury or damage to persons or things CAUTION Explanation of Picture Symbols Denotes an important warning or caution Denotes a forbidden action Inside or near the symbol will appear another symbol giving details EX stands for DO NOT TAKE APART Denotes an action that you must take OV VO CO GO BOUe N DANGERS Do not take apart repair or modify the main unit Doing so may cause fire or electrocution If water or a foreign body enters into this unit immediately remove the batteries and stop using Continued use may cause fire or electrocution Do not use this
8. to install properly the following display will appear in the Device Manager 8 Sound video and game controllers System devices Universal Serial Bus controllers USB Recorder Com USB Device If this occurs please re install from the USB Device properties How to Re install 1 In the Device Manager Window right click on USB Device under Other Devices to display the USB Device Properties Universal Serial Bus controllers USB Recorder Com EL Update Driver pens property sheet for Disable ns Uninstall Scan For hardware changes a 2 In the USB Device Properties Window click on the Reinstall Driver button to display the Installation Window Follow the directions to install USB Device Properties USB Device Device type USB Recorder Com Manufacturer T amp D Corporation Location USB Device Device status The drivers for this device are not installed Code 28 To reinstall the drivers for this device click Reinstall Driver Reinstall Driver Rei n stal l D rive r button Device usage Use this device enable 2 Specifications Device Type TR 71U TR 72U 2 Channels Select from ch1 internal No of Measurement 2 Channels Channels ch 2 external 1 Temperature 1 Humidity Measurement Items Temperature Temperature Humidity Internal Temperature 10 to 60C 10 to 60C _ Sensor Attache
9. unit in wet or humid places such as a bathroom Store main units sensors batteries and communication cables out of the reach of children It is dangerous to touch or swallow batteries If any smoke or strange smells are emitted from the unit immediately remove the batteries and stop using Continued use may cause fire or electrocution Do not drop the unit or expose the unit to a strong impact If that happens to the unit immediately remove the batteries and stop using Continued use may cause fire or electrocution This device is designed to measure and record temperature and humidity Do not use it for any other purpose than to measure and record temperature and humidity This unit is not water resistant If the unit gets dirty wipe it with a clean cloth and a mild detergent Do not expose the unit to harmful gases or chemicals It may cause corrosion and or other danger to the unit and to people handling the unit Ye POS Obie N CAUTIONS Do not use batteries other than specified Doing so may cause fire or damage Battery terminals may provide insufficient contact due to age or vibration This may lead to data loss Condensation may occur if the unit is moved from one environment to another where the difference in temperature is great Use the unit in an environment where the ambient temperature is from 10 to 60 C and the humidity is 90 RH no condensation or less To prevent damage to the unit f
10. Thermo Recorder TR 71U TR 72U User s Manual Thank you for purchasing our product Carefully read this instruction manual before using this unit CE Copyright 2004 T amp D Corporation All rights reserved 2004 08 16004374040 Notices about this User s Manual In order to properly use this product please carefully read this manual before using T amp D Corporation accepts no responsibility for any malfunction of and or trouble with this product or with your computer that is caused by the improper handling of this product and will deem such trouble or malfunction as falling outside the conditions for free repair outlined in the attached warranty All rights of this Users Manual belong to T amp D Corporation It is prohibited to use duplicate and or arrange a part or whole of this User s Manual without the permission of T amp D Corporation Microsoft and Windows are registered trademarks of Microsoft Corporation USA and are binding in the USA and all other countries Company names and product names are trademarks or registered trademarks of each company Specifications design and other contents outlined in this manual are subject to change without notice On screen messages in this manual may vary slightly from the actual messages Please notify the shop where you purchased this product or T amp D Corporation of any mistakes errors or unclear explanations in this manual T amp D Corporation acc
11. d Sensor 40 to 110 C 0 to 50 C 10 to 95 RH Optional Temp Sensor 60 to 155C X1 40 to 110 C Measuring Accuracy Average 0 3 C 20 to 80 C 5 RH with Attached Sensor Average 0 5 C 40 to 20 80 to 110 C at 25 C 50 RH Measuring 0 1 C 1 RH Display Resolution Macromolecular Sensor Thermistor Humidity Sensor Select from 15 choices 1 2 5 10 15 20 30 seconds a Umea 1 2 5 10 15 20 30 60 minutes Recording Capacity 8000 readings X 2 channels Recording Modes Endless Mode One time Mode Ch1 only Ch2 only alternating display Measurements LCD display Recording Status Battery Life Warning Amount of Recorded Data Unit of Measurement Power AA alkaline battery LR6 Battery Life About 1 year X 2 Data Backup Activated when battery power is low or when switch is off About 1 year Interface USB Communication Cable option RS 232C e Communicalon When downloading 1 unit of full data about 8 seconds Dimensions Weight of Main Unit H55 X W78 X D18 mm about 62 g including one AA battery Working Environment Temperature 10 to 60 C for Main Unit Humidity under 90 RH without condensation Attached Sensors TR 0106 X 2 TR 3100 X 1 AA alkaline battery LR6 X 1 User s Manual Warranty Xx 1 USB cable X 1 US 15C length 1 5 m Software set X 1 User s Manual Warranty x 1 Accessories included in package x1 There are two typ
12. e sensor is connected to only the ch 2 jack the internal sensor will be used to measure for ch 1 To avoid poor connections be sure to push the sensor connector securely into the jack Note If a sensor extension cable is being used with the data logger connected by USB to your computer electromagnetic waves may cause large errors in measurements TR 72U Thermo Recorder TR 72U Caution When using the temperature humidity sensor in environments where the temperature is 0 to 15 and humidity under 30 RH there may occur changes in measurement readings This is not a malfunction To avoid poor connections be sure to push the sensor connector securely into the jack 23 24 Handling the temperature humidity sensor The temperature humidity sensor should be changed after a period of about one year After removing the sensor from its package please change the temperature humidity sensor after one year s usage During use the temperature humidity sensor will accumulate impurities dirt on the surface of the sensor causing the sensor s accuracy and sensitivity to decrease If the sensor is being used in a bad environment smoky or dusty places it may be necessary to change the sensor sooner When the temperature humidity sensor is not being used please place it in the attached vinyl bag with the drying agent included and store it in a cool dark place with a temperature of between 5 to 25 C and a humidity of bel
13. ed and click the Next button Add New Hardware Wizard 7 Check Specify a location and click the Browse button Select the Device Driver in the CD ROM drive and click Next i Add New Hardware Wizard Check Browse button 20 8 Click Next to start the installation Add New Hardware Wizard 9 After completing installation click the Finish button Add New Hardware Wizard Caution If the Driver is not automatically detected please search by specifying the place as CD ROM Device Driver and install manually from there 21 Checking After Connecting 1 Open the Control Panel and double click on System the system properties will be displayed 2 Click the Device Manager Tab and the Device Manager Window will appear Device Manager Tab General Device Manager Hardware Profiles Perfomance View devices by type C View devices by connection 2 CDROM amp Disk drives Display adapters 3 Floppy disk controllers Sy Hard disk controllers E Keyboard Monitors Mouse EF Network adapters Other devices 37 Ports COM amp LPT System devices P c H a Jf 0 A fi mm Ollers USB Recorder1 ok Properties Refresh Remove Print 3 Check to see if USB Recorder 1 is listed under USB Recorder COM 22 Connecting the Sensor Connecting the Sensor TR 71U Thermo Recorder TR 71U If a temperatur
14. epts no responsibility for any damage or loss of income caused by the use of our product This product has been designed for private or industrial use only It is not for use in situations where strict safety precautions are necessary such as in connection with medical equipment whether directly or indirectly We are not responsible for any malfunction or trouble caused by the use of our product or by any problem caused by the use of measurement results of our unit Please be fully aware of this before using our product Some of our products which come under the category of strategic goods in foreign trade law need the permission of the Japanese government to be exported outside of Japan This Users Manual cannot be reissued so please keep it in a safe place Please read the warranty and provisions for free repair carefully FCC Compliance Statement for American Users This device complies with Part 15 of the FCC Rules Operation is subject to following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Note This equipment has been tested and found to comply with the limits for a Class A Digital Device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can
15. ermo Recorder TR 72U X 1 unit T amp D Recorder for Windows Software CD ROM X 1 AA Alkaline Battery USB Communication Cable LR6 X 1 Temperature Sensor US 15C X 1 TR 3100 X 1 Hardware Users Manual Warranty x 1 Software User s Manual X 1 Part Names and Functions Part Names FRONT Thermo Recorder TR 71U o Ha By o E N lt b s m D DISPLAY INTERVAL REC STOP button button button DISPLAY Pressing this button will change the LCD display mode INTERVAL Pressing this button will display the currently set recording interval REC STOP Pressing this button will start or stop recording RIGHT SIDE LEFT SIDE Sensor Jack Channel 1 USB Cable Jack Sensor Jack Channel 2 l Only for TR 71U ii Serial Cable Jack POWER Switch X 1 Serial Communication Cable is an Optional Accessory LCD Display Channel Mark The channel number of the measurement being displayed will appear Recording Mark The recording condition will appear ON Recording in progress BLINKING Waiting for programmed start Data Capacity Scale After every 2000 readings the scale will be marked from left to right COM Mark This will appear when data is being sent or received ON USB cable is connected BLINKING In communication with computer Recording Mode ONETIME When the number of recorded readings reaches 8000 FULL will appear i
16. es of temperature sensor for TR 71U depending on measurement range For details see Optional Accessories on p 29 x2 Battery life depends upon the measuring environment recording interval and quality of the battery being used 28 Optional Accessories Temperatue Sensors For TR 71U unit millimeters TR 1106 Teflon Shielded Sensor Cable Length 0 6m E Thermal Constant Time s In the air Approx 15 Sec D In agitated water Approx 2 Sec TR 1220 Stainless Protection Sensor Cable Length 2 0m 18 a T T Thermal Constant Time In the air Approx 36 Sec Pr 5 we 4 9 wM In agitated water Approx 7 Sec 5 30 2000 TR 1320 Stainless Protection Sensor 2000 Cable Length 2 0m 7 caesar Gk Thermal Constant Time Fy T 4 j T In the air Approx 12 Sec In agitated water Approx 2 Sec Materials Thermistor Stainless pipe SUS316 3 Teflon Compaction Tube Teflon Resin FEP Shielded Possible Measurement Range 60 to 155 C Sensor Temperature Durability 70 to 180 C Water Resistance Splash Proof Sensor and Cable Measurement Accuracy Average 0 3 C 20 to 80 C Average 0 5 C 40 to 20 C 80 to 110 C Average 1 0 C 60 to 40 C 110 to 155 C unit millimeters TR 0106 TPE resin Shielded Sensor Cable Length 0 6m e r E T 800 Thermal Constant Time In the air Approx 75 Sec 29 TR 0206 Stai
17. icrosoft Windows Update lt Back Next gt Cancel 13 8 By clicking the Next button installation will begin Found New Hardware Wizard Driver Files Search Results The wizard has finished searching for driver files for your hardware device S The wizard found a driver for the following device o USB Device Windows found a driver for this device To install the driver Windows found click Next Sy d devicedriver recusb01 inf Caution If the Driver is not automatically detected please search by specifying the place as CD ROM Device Driver and install manually from there 9 After completing installation click the Finish button Found New Hardware Wizard Completing the Found New Hardware Wizard gt USB Recorder1 Windows has finished installing the software for this device To close this wizard click Finish lt Back Carcel 14 Checking After Connecting 1 Open the Control Panel and double click on System the system properties will be displayed 2 Click the Hardware Tab and click the Device Manager button in the Device Manager Area Device Manager Hardware Tab General Network Identification Hardware User Profiles Advanced r Hardware Wizard The Hardware wizard helps you install uninstall repair oh unplug eject and configure your hardware Hardware Wizard i Device Manager m The Device Manager list
18. n the unit s LCD display and recording will automatically stop ENDLESS When the number of recorded readings reaches 8000 the oldest data reading will be overwritten and recording will continue Battery Life Warning Signal When the battery power becomes low this will appear in the LCD display If the battery power becomes even lower SLP will appear and normal operations will stop If the lt 2 signal appears please change the battery as soon as possible Unit of Measurement The unit of measurement C F for the display will appear Measurements and Messages Area Current measurements or operational messages such as FULL or SLP will appear Installing the Battery 1 Remove the battery cover form the back of the unit 2 Insert 1 AA alkaline battery making sure that the and are in the correct direction Always use a new battery 3 Replace and close the battery cover Changing the Battery 1 When battery power becomes low a battery life warning signal will appear in the unit s LCD display If at this time you change the battery recording will continue uninterrupted and all data will be saved for downloading 2 If the battery is not changed and power becomes even lower SLP will appear in the LCD display The unit will automatically go into sleep mode in order to protect the data and all normal operations will stop If you change the battery at this point it is still possible to download all
19. nit will automatically go into sleep mode in order to protect the data In sleep mode all normal operations will stop and it will become impossible to switch on the power of the main unit Note If the main unit remains in sleep mode for about 1 month without a change of battery or if the battery is left out of the unit for more than 2 minutes all recorded data will be lost Current Readings Monitoring Display With our exclusive software you cannot only monitor the current measurements at a set interval but can view those measurements in a continually changing graph You can simultaneously display the current measurements and corresponding graphs for the number of units you have connected Adjustment Function Bt setting adjustment values beforehand you can record and display the post adjusted measurement values You can choose from two adjustment methods 1 point and 2 point Adjustment will be carried out using an adjustment equation of Y aX b where X is the pre adjusted measurement value and Y is the post adjusted value Package Contents The following items are included in the package TR 71U Thermo Recorder TR 71U X 1 unit T amp D Recorder for Windows Software CD ROM x 1 TD FTE AA Alkaline Battery USB Communication Cable Temperature Sensor LR6 x 1 US 15C X 1 TR 0106 X 1 Hardware Users Manual Warranty x 1 Software User s Manual X 1 TR 72U Th
20. nless Protection Sensor Cable Length 0 6m _ _ _ Thermal Constant Time Tr SS In the air Approx 75 Sec poe i n TR 0306 Stainless Protection Sensor Cable Length 0 6m d r 40 i B00 Thermal Constant Time r In agitated water Approx 18 Sec X Only stainless section is water resistant 5 TR 0406 Stainless Protection Sensor Cable Length 0 6m Thermal Constant Time In agitated water Approx 20 Sec X Only stainless section is water resistant TR 0506 Stainless Protection Sensor Cable Length 0 6m i 83 T al Thermal Constant Time u a In agitated water Approx 20 Sec X Only stainless section is water resistant TR 0706 Stainless Protection Sensor Cable Length 0 6m N Thermal Constant Time en I In agitated water Approx 18 Sec i 4 a X Only stainless section is water resistant Materials Thermistor TPE resin shielded sensor TPE resin shielded wire M3Screw Hole Compacion Tube Stainless pipe SUS304 Stainless pipe SUS316 Possible Measurement Range 40 to 110 C Sensor Temperature Durability 50 to 115 C Measurement Accuracy Average 0 3 C 20 to 80 C Average 0 5 C 40 to 20 C 80 to 110 30 Sensor Extension Cable Temp Sensor Only unit millimeters TR 1C30 Cable length 3 0m Materials Vinyl Coated Electrical Wire Note Only one cable per sensor When using the exten
21. order for Windows you can easily install the USB Device Driver For Windows XP 1 Turn on your computer and open Windows 2 After Windows has been completely started up connect the supplied USB cable to a USB port on your computer 3 Insert the attached CD ROM in the CD ROM drive Caution If the Installation Window opens close it 4 By connecting a data logger to the USB cable already connected to your computer the Add Hardware Wizard will automatically open 5 By checking Install the Software automatically Recommended and clicking Next the software will automatically be installed Found New Hardware Wizard Welcome to the Found New Hardware Wizard This wizard helps you install software for USB Device 9 If your hardware came with an installation CD Q or floppy disk insert it now What do you want the wizard to do Completing the Found New Hardware Wizard The wizard has finished installing the software for USB Recorder1 Click Finish to close the wizard Caution If the Driver is not automatically detected please search by specifying the place as CD ROM Device Driver and install manually from there 10 Checking After Connecting 1 Open the Control Panel and double click on System the system properties will be displayed 2 Click the Hardware Tab and click the Device Manager button in the Device Manager Area Hardware Tab System Properties
22. ow 30 RH Attached to the temperature humidity sensor are two stickers a wetness detection sticker and a temperature detection sticker If either of the sticker shows abnormality you should change the old sensor with a new one immediately Wetness Detection Sticker Temperature Detection Sticker Wetness Detection Sticker Informs you that the sensor has been wet Normal Abnormal Under normal conditions black Under abnormal conditions it dots will appear on a white will turn to red background Temperature Detection Sticker Informs you that the sensor measured a temperature measurement over 60 C Normal Abnormal Under normal conditions the Under abnormal conditions the number 601 will lightly appear on a number 60 will clearly appear on a pinkish white background red background Starting Recording from Main Unit Switch By pressing the REC switch on the main unit you can start a recording session immediately Caution If you wish to make changes to the device name channel name recording mode or to any other recording conditions you must make those settings by connecting the device to your computer Starting a Recording Session Press in the REC STOP button on the front of the unit until the REC mark appears in the display When displayed recording has begun REC mark lights up REC DATA COM ENDLESS Z tlt D Cb hal Note By starting a new recording session all da
23. r on a number 601 will clearly appear on a pinkish white background red background vill Contents Safety Precautions and Instructions iii About Thermo Recorder TR 71U 72U 1 Package Contents 3 Part Names and Functions 5 Installing the Battery 7 Turning on the Power 8 Installing the USB Device Driver 9 Windows XP 9 Windows 2000 12 Windows Me 16 Windows 98 19 Starting Recording from Main Unit Switch 27 Setting Recording Interval from Main Unit Switch 28 If Installation Fails 29 Specifications 31 Optional Accessories 32 Warranty
24. radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Warning This equipment has been verified to comply with the limits for a Class A personal digital device pursuant to Subpart B of Part 15 of FCC Rules Only peripherals computer input output devices terminals printers etc certified or verified to comply with the Class A or B limits may be attached to this equipment Operation with non certified or non verified personal computer and or peripherals is likely to result in interference to radio and TV reception The connection of a non shielded equipment interface cable to this equipment will invalidate the FCC Certification of this device and may cause interference levels which exceed the limits established by the FCC for this
25. re Wizard Welcome to the Found New Hardware Wizard This wizard helps you install a device driver for a hardware device To continue click Next 12 6 Check Search for a suitable driver for my device recommended and click the Next button Found New Hardware Wizard Install Hardware Device Drivers device driver is a software program that enables a hardware device to work with an operating system This wizard will complete the installation for this device USB Device device driver is a software program that makes a hardware device work Windows needs driver files for your new device To locate driver files and complete the installation click Next What do you want the wizard to do Display a list of the known drivers for this device so that can choose a specific driver 7 Check CD ROM and then click the Next button Found New Hardware Wizard Locate Driver Files Se SZ Where do you want Windows to search for driver files eS Search for driver files for the following hardware device oa USB Device The wizard searches for suitable drivers in its driver database on your computer and in any of the following optional search locations that you specify To start the search click Next If you are searching on a floppy disk or CD ROM drive insert the floppy disk or CD before clicking Next Optional search locations I Floppy disk drives eae I M
26. rom static electricity remove static electricity from your body by touching metal around you door knob window frame before touching the unit Static electricity may cause not only damage to the unit but may cause breaks in or a loss of data If the unit will not be used for period of time for safety reasons please remove the battery If left in the unit it may leak and lead to malfunctioning Please take extra caution when plugging in and pulling out the USB plug while another USB device such as CD RW HDD is in operation It may cause problems to your CD RW or other device We shall not guarantee the operation of our device if you have connected it to your computer using a USB hub or a USB extension cable Please do not insert your fingers or any foreign objects into any of the devices jacks O N CAUTIONS Do not use any other batteries than those that are specified in this User s Manual It may cause a fire or other trouble including malfunction Do not use or store the Thermo Recorder in any of the following places Doing so may cause electrocution fire and or other adverse effects to the device and or your computer Areas exposed to direct sunlight This will cause the inside of the device to become overheated and may cause fire deformation and or other damage including malfunction Areas prone to strong magnetic fields This may cause damage including malfunction Areas exposed to water leakage
27. roperties will be displayed 2 Click the Device Manager Tab and the Device Manager Window will appear Device Manager Tab General Device Manager Hardware Profiles Performance View devices by type View devices by connection CDROM amp Disk drives Ss Display adapters Floppy disk controllers Hard disk controllers E Keyboard c Monitors T Mouse 89 Network adapters aF Ports COM amp LPT 1 BB A USB Recorder1 Properties Refresh Remove Print cova 3 Check to see if USB Recorder 1 is listed under USB Recorder COM 18 For Windows 98 1 Turn on your computer and open Windows 2 After Windows has been completely started up connect the supplied USB cable to a USB port on your computer 3 Insert the attached CD ROM in the CR ROM drive X If the Installation Window opens close it 4 By connecting a data logger to the USB cable already connected to your computer the Add New Hardware Wizard will automatically open 5 By clicking the Next button a window will open where you can choose how you wish to find the driver file Add New Hardware Wizard This wizard searches for new drivers for USB Device device driver is a software program that makes a hardware device work 19 6 Check Search for the best driver your device Recommend
28. s all the hardware devices installed on your computer Use the Device Manager to change the properties of any device Driver Signing i 3 In the Device Manager Window check to see if USB Recorder 1 is listed under USB Recorder COM Floppy disk drives Sy IDE ATA ATAPI controllers Keyboards A Mice and other pointing devices 3 Monitors S Network adapters l Y Ports COM amp LPT E g Sound video and game controllers a System devices USB Recorder Com amp USB Recorder1 15 16 For Windows Me 1 Turn on your computer and open Windows 2 After Windows has been completely started up connect the supplied USB cable to a USB port on your computer 3 Insert the attached CD ROM in the CR ROM drive X If the Installation Window opens close it 4 By connecting a data logger to the USB cable already connected to your computer the Add New Hardware Wizard will automatically open 5 Check Automatic search for a better dirver Recommended and click the Next button to begin installation Add New Hardesre Wizard 6 After completing installation click the Finish button Bancel Caution If the Driver is not automatically detected please search by specifying the place as CD ROM Device Driver and install manually from there 17 Checking After Connecting 1 Open the Control Panel and double click on System the system p
29. sion cable there will be a 0 3 C at normal temperature and at 50 C a gap of 0 5 C may occur If a sensor extension cable is being used with the data logger connected by USB to your computer electromagnetic waves may cause large errors in measurements Do not use the Extension Cable with TR 72U Temp Humidity Sensors For TR 72U TR 3100 Temp Humidity Sensor TR 3110 Temp Humidity Sensor Cable length 1m Materials Temperture humidity sensor Polypropylene resin Vinyl Coated Electrical Wire Possible temperature measurement range 0 to 55 C Possible humidity measurement range 10 to 95 RH Sensor temperatur resistance 10 to 55 C humidity measurement accuracy 5 RH At 25 C 50 RH Service life 1 year under normal operational conditions Operational conditions Without dew condensation water leakage or effect from corrosive gas or organic solvents Note An Extension Cable cannot be used with Temperature Humidity Sensors 31 Serial Communication Cable for TR 71U 72U TR 07C Serial Communication Cable Cable Length about 1 0 m Connector Type Specialized Connector D sub9pin For communication with computer TR 4C10 Serial Communication Cable Cable Length about 1 0 m Connector Type Specialized Connector e TE D sub9pin For communication with RTR 57C Wall Attachment for TR 71U 72U unit millimeters TR 07K2 Wall Attachment
30. ta currently saved in the unit will be erased Even if the unit is waiting for a programmed start by pressing the REC STOP button until the REC mark appears you can start a new recording session immediately Stop Recording You can stop a recording session by pressing the REC STOP button until the REC mark disappears from the display When it has disappeared recording has stopped REC mark disappears f DATA COM ENDLESS DI LAL c 25 26 Setting Recording Interval from Main Unit Switch You can make or change recording interval settings from the INTERVAL switch on the front of the TR 71U 72U main unit 1 Press in the INTERVAL button on the front of the device until the recording interval appears in the display 2 With each pressing of the INTERVAL button the recording interval time will change Press until the desired setting appears DATA ENDLESS DATA ENDLESS ET IE l P Vd 15 seconds 15 minutes 3 When the desired recording interval appears stop pressing the INTERVAL button Within a few seconds the current measurement readings will return to the display and the setting will be finished By pressing the INTERVAL button during recording or while waiting for a programmed recording to start the currently set recording interval will be displayed If Installation Fails If during USB device driver installation some trouble occurs that results in a failure
31. y Our low energy consumption design gives you one year of continuous operation with only one AA alkaline battery This gives you the freedom to use the data loggers in places where they can be left alone for long periods of time such as in transportation or refrigeration Note Battery life varies depending upon the type of battery the measuring environment the frequency of communication and the ambient temperature in which it is used Specifications and explanations used in this User s Manual are based on operations carried out with a new battery and are in no way a guarantee of your actual battery life Battery Life Warning Display When the battery power becomes low a battery life warning signal will appear in the unit s LCD display If the battery power becomes even lower the unit will automatically go into sleep mode in order to protect the data 15 Recording Intervals Select from 15 Recording Intervals from 1 second to 1 hour to meet your needs Select from 2 Recording Modes One time Mode When the number of recorded readings reaches 8000 FULL will appear in the unit s LCD display and recording will automatically stop Endless Mode When the number of recorded readings reaches 8000 the oldest data reading will be overwritten and recording will continue Backup Function When battery power becomes low a battery life warning signal will appear in the unit s LCD display and if the battery power becomes even lower the u