1. Discharge Protection h Fuses F1 Auxiliary F2 Battery i Housing Front Cover Back Box Maximum Current During Alarm Voltage Maximum Current Short Circuit Open Circuit Voltage Maximum Current Protection Call 13 8 VDC Less than 10 5 VDC 1 12 VDC 10 30mA gt 30mA lt 1 5mA 1 12 VDC 10 200mA Shut Down At 1 Hz Pulse 500mA Anti Surge 20mm Glass 500mA Anti Surge 20mm Glass Polycarbonate Fire Retardant Polycarbonate Fire Retardant 30 mA DC Maximum 4 2 DPTA PC Pull Cord Ceiling Mounted a Power Supply Input Voltage Quiescent Standby Current Maximum Current During Alarm 12 VDC OmA 15 mA DC Maximum Section 4 Product Specifications b User Operation Action Response Pull Card Alarm Activation c LED LED System Status LED Response Front Mounted Alarm Activation Illuminates in Sympathy with System d Termination Device is wired with 3 wires positive negative amp signal in and 3 wires positive negative amp signal out e Housing Material ABS Colour White 4 3 DPTA RR Remote Reset Surface Flush Mounted a Power Supply Input Voltage 12 VDC Quiescent Standby Current OmA Maximum Current During Alarm 15 mA DC Maximum b User Operation Action Response Pull Card Alarm Activation c LED LED System Status LED Response Front Mounted Alarm Activation Illuminates in Sympathy with System d Termination Device is wired wit
2. OUT DPTA CP DPTA RI GA IN IN IN_SIG OUT_SIG OUT OUT DPTA PC IN IN IN SIG 1 1 SIG1 2 2 SIG2 3 3 SIG3 4 4 SIG4 Zone 1 Zone 2 Zone 3 Zone 4 DPTA CP AC 230V 50 650Hz 12V DC 11
3. Specifications 4 Product Specifications 4 1 DPTA CP Control Panel Surface Flush Mounted a Power Supply Mains Input Voltage Quiescent Standby Current Maximum Overall Supply Current DC Input Voltage b Button Functions Button Silence Reset Zone 1 Zone 2 Zone 3 Zone 4 c Led s LED Mains Green Alarm Zone 1 2 3 4 Red d Internal Buzzer Type Current Frequency Sound System Status Alarm Activation Alarm Activation Alarm Activation Alarm Activation Alarm Activation Alarm Activation System Status Mains On Battery Back Up Battery Saver Pulse Alarm Activation 230VAC 50Hz 60Hz 3mA DC Buzzer Muted 250 mA DC Maximum 12VDC Battery Operation Press for 0 5 Seconds Press for 0 5 Seconds Press for 0 5 Seconds Press for 0 5 Seconds Press for 0 5 Seconds Press for 0 5 Seconds Piezo PCB Mounted 5mA maximum 1 Khz Tone Function Mute Control Panel Rest All Zones Reset Zone 1 Reset Zone 2 Reset Zone 3 Reset Zone 4 LED Response Constant Mains Present Pulse Every 5 Seconds Every 20 Seconds Slow Flashing 1 Hz 1 Hz Pulse Alarm Activation Mute System Normal Beep Every 20 Seconds Battery Saver Mode Section 4 Product Specifications e Field Device Inputs Number of Zone Circuits Detection Supply Detection Mode Monitoring f Field Device Outputs Number of Zone Circuits Sounder Supply Alarm g Battery Input Charging Voltage Deep
4. User Manual Disabled Persons Toilet Alarm opt DPTA KIT3 DPTA KIT4 Contents Contents Section 1 Introduction Section 2 Features Section 3 Typical Installation Section 4 Product Specifications Section 5 Electrical Requirements Section 6 Wiring Diagram U A UW 10 11 Section 1 Introduction 1 Introduction This Disabled Persons Toilet Alarm Kit is available in 1 2 3 or 4 zones where one zone is used for each toilet It has been designed for use in disabled persons dwellings typically for disabled toilets where this design process considered the requirements of BS8300 The system consists of a 4 zone control panel DPTA CP4 which is for each zone connected to a Pull Cord DPTA PC Remote Reset DPTA RR and Remote Indicator DPTA RI These connected items are known as field devices which provide the Control Panel with the necessary input and output signals to allow the system to function These field devices are categorised as follows JY Pull Cords DPTA PC are Call Devices which are ceiling mounted pull cords used to generate an alarm activation by a person in distress or requiring attention from a carer When a call devices is activated the system will generate an alarm and the Remote Indicator DPTA RI will illuminate amp sound D V Remote Resets DPTA RR are Reset Devices which are generally wall mounted and consist of a push button which is pressed to cancel an alarm activa
5. h 3 wires positive negative amp signal in and 3 wires positive negative amp signal out Section 4 Product Specifications e Housings Material ABS Colour White 4 4 DPTA RI Remote Indicator Surface Flush Mounted a Power Supply Input Voltage 12 VDC Quiescent Standby Current OmA Maximum Current During Alarm 30 mA DC Maximum c LED LED System Status LED Response Front Mounted Alarm Activation Illuminates in Sympathy with System d Termination Device is wired with 3 wires positive negative amp signal in and 3 wires positive negative amp signal out e Housings Material ABS Colour White Section 5 Electrical Requirements 5 Electrical Requirements A Power Supply Y 230V AC at 50 60Hz V 12V DC Storage battery JY Standby Current 4mA J Alarm Current 250mA max B DPTA CP Internal Safety Fuses F1 Auxiliary 500mA Anti Surge Timed The Auxiliary Fuse protects the DPTA CP circuitry field devices and field device wiring from current overload The field device wiring is protected with electronic current limiting F2 Battery 500mA Anti Surge Timed The battery fuse protects the DPTA CP battery supply from overload either while charging or in Standby Section 6 Wiring Diagram 6 Wiring Diagram E E E OUT_SIG OUT OUT DPTA RR O Wiring of field devices for IN IN IN_SIG each zone which can be wired in any order once spurred from control panel OUT_SIG OUT
6. tion VY Remote Indicators DPTA RI are Warning Devices that are generally wall mounted devices which during f an alarm activation will alert cares staff of a person amp requiring attention Warning devices typically have visual and audible element within the same housing but devices with only audible or visual elements may be fitted to a system J O77 V The control panel DPTA CP is powered by mains supply and an optional battery back up can be installed which allows the system to function during a power outage Section 2 Features 2 Features V Simple 3 wire operation for all field devices Y Control Panel supporting up to 4 zones V Simple maintenance and fault diagnosis JY On board buzzer in both Control Panel amp Remote Indicator V Zone LED indication on Control Panel V Full range of field devices available i e Pull Cord Remote Reset amp Remote Indicator V System silence mute option from Control Panel Y Local at Control Panel or remote at Remote Reset reset options V Optional battery back up V Auto shut down function to save battery power Section 3 Typical Installation 3 Typical Installation The following illustration shows how the Control Panel and field devices are connected in a typical installation for a single toilet Up to four toilets on one panel Pull Cord DPTA PC Control Panel DPTA CP Remote Indicators DPTA RI Section 4 Product