Home

USER MANUAL - Security Dynamics

image

Contents

1. MOVE 4 TO SAVE amp EXIT SET TILT LIMITS Default setting is on Limits are determined by the Camera Orientation set up see 6 4 7 All X Series Cameras have the following viewing tilt angle In Dome configuration i e with lid 90 to 10 above horizon In Ball configuration i e without lid 90 to 60 above horizon Default tilt setting is ON Limits are determined by the Camera orientation setup See 6 4 7 gt LOGIN gt MAIN MENU gt JOYSTICK gt TILT LIMIT gt SET TILT MOVE TO SELECT ON OFF gt MOVE 4 TO SAVE amp EXIT SHORT CUTS It is possible to allocate a PRESET number to activate the WIPER WASH or NIGHT MODE SWITCHING gt LOGIN gt MAIN MENU gt JOYSTICK gt SHORTCUTS MOVE gt gt TO SELECT WIPERWASH NIGHTMODE SWITCHING MOVE SELECT NO PRESET OR PRESET NUMBER BETWEEN 1 100 gt MOVE 4 TO SAVE amp EXIT TECH SUPPORT COMMENT Ifa preset number is allocated to the wiper or IR lamp function it cannot be used for a preset position The wiper or IR function will over ride a preset position if it shares the same preset number AUXILLARY RELAY FUNCTION If using an RVX PSU ALM16 or RVX PSU AALM16 W the auxilliary relay can be programmed to transmit active alarms only or trigger when the camera switches to IR NIGHT MODE e g Switch on additional IR or WHITE LIGHTING etc gt LOGIN gt MAIN MENU gt JOYSTICK gt AUX RELAY FUN gt MOVE
2. Redvision USER MANUAL Products Covered 0 RV X SERIES PTZ Positioning Camera RVX PSU Power Supply RVX PSU ALM16 Power Supply with Alarm Module RVX PSU ALM16 W PSU with Wireless PIR module RVX V9 2 7 2012 Redvision CCTV Limited All rights reserved Table of Contents 1 INSTALLING THE CAMERA HEAD 1 1 1 2 1 3 1 4 CONVERT DOME TO BALL PTZ CONFIGURATION ATTACHING CAMERA TO BRACKET BRACKET TYPES HOW TO CANTILEVER BALL PTZ ARMS FORWARD 2 HOW TO CONFIGURE THE CAMERA 2 1 2 1 1 21 2 2 2 2 3 2 4 2 5 2 6 2 7 REMOVING THE DIP SWITCH SCREW COVER CAMERA ORIENTATION FOR SETTING DIP SWITCHES DEFAULT DIP SWITCH SETTINGS SETTING THE CAMERA ADDRESS SETTING THE CAMERA PROTOCOL SETTING THE CAMERA BAUD RATE SETTING THE CAMERA RS485 TERMINATION REAL TIME CLOCK RTC REPLACING THE DIP SWITCH COVER 3 POWER SUPPLY INSTALLATION 3 1 3 2 3 3 3 3 1 3 3 2 3 3 3 3 3 4 3 3 5 REDVISION POWER SUPPLY RVX PSU VOLTAGE RVX PSU INTERNAL CONNECTIONS MAINS INPUT CONNECTIONS TO CAMERA 8 WAY BLOCK CONNECTIONS TO CONTROL 8 WAY BLOCK RS485 DIAGNOSTIC LEDS FUSE PROTECTION 4 RVX PSU ALM16 PSU WITH ALARM MODULE 4 1 4 2 4 2 1 4 2 2 4 2 3 4 2 4 4 2 5 4 3 4 3 1 4 3 2 4 3 3 4 4 4 4 1 4 4 2 4 5 4 5 1 VOLTAGE RVX PSU ALM16 CONNECTIONS MAINS INPUT CONNECTIONS TO CAMERA 8 WAY BLOCK CONNECTIONS TO CONTROL 8 WAY BLOCK RS485 DIAGNOSTIC LEDS FUSE PROTECTION ALARM MODULE D
3. RVX PSU ALM16 INTERNAL CONNECTIONS MAINS INPUT TABLE 11 IDENT MAINS POWER LIVE LIVE BROWN 110 230Vac Connection via 2 way terminal block NEUTRAL NEUTRAL BLUE Connection via 2 way terminal block EARTH GREEN YELLOW Connection via earth terminal screw NOTE Earth connection requires 4mm red spade loop supplied with PSU to be fitted by engineer at installation SAFETY ENSURE MAINS INPUT amp EARTH CONNECTIONS ARE SECURELY STRAIN RELIEVED 4 2 2 4 2 3 4 2 4 4 2 5 4 3 X SERIES USER MANUAL CONNECTIONS TO CAMERA 8 WAY TERMINAL BLOCK PCBIDENT UMBILICAL LEAD TO CAMERA N C Normally Closed N C Normally Closed VIDEO Coax signal BNC 7 V GND Coax screen RS485 A White IVE RS485 B Orange 24V Red ov Black and cable screen CONNECTIONS TO CONTROL 8 WAY TERMINAL BLOCK PCBIDENT CONTROL CONNECTIONS AUX C AUX E VIDEO COAX signal BNC P6 V GND COAX screen RS485 A RS485 A RS485 B RS485 B 24V Red OV Black and cable screen RS485 DIAGNOSTIC LEDs STATUS DESCRIPTION RED OFF GREEN OFF DISCONNECTED RED OFF GREEN ON OK IDLE RED FLASH GREEN FLASH OK TRAFFIC PASSING RED ON GREEN ON A B REVERSED FUSE PROTECTION PCB IDENT DESCRIPTION Mains input fuse 3 15A Anti Surge Camera fuse 3 15A Fast Blow ALARM MODULE DIP SWITCH SETTINGS Refer to S5 CONFIG DIP SWITCH see diagram in FIG 8 page 8 for Setting Protocol Baud Rate amp RS485 te
4. 11 1 SET CLEAR MASK LOGIN gt MAIN MENU gt PRIVACY gt SET CLEAR MASK MOVE TO SELECT A MASK NUMBER MOVE TO REVEAL CROSS HAIRS MOVE CAMERA TO REQUIRED VIEW USING PTZ CONTROLS SELECT ENTER COMMAND FROM CONTROL OR WAIT 15 SECS UNTIL RED PATCH APPEARS MOVE TO SCROLL TO NEXT MASK NUMBER REPEAT STEPS 3 TO 5 TO CREATE NEW PRIVACY MASKS MOVE 4 TO SAVE amp EXIT Villi iV 11 2 ZOOM THRESHOLD gt LOGIN gt MAIN MENU gt PRIVACY gt ZOOM THRESHOLD MOVE v 0 100 MOVE 4 TO SAVE amp EXIT 11 3 EDIT MASK gt LOGIN gt MAIN MENU gt PRIVACY gt EDIT MASK MOVE TO SELECT A MASK NUMBER BE EDITED CLEAR MASK YES NO MOVE 4 TO SAVE amp EXIT 9 X SERIES USER MANUAL 12 ALARM HANDLING IN MENU SOFTWARE 12 1 12 2 12 3 The alarms can be mapped to any preset or tour or to just put a message on the screen Within the Alarm Edit menu 12 4 use to select alarm number within each alarm you can set type of action dwell and time based masking for weekdays 12 4 1 amp weekends 12 4 2 The time based masking is SECONDARY to the Enable alarms menu 12 1 If the alarm is not enabled it will be completely ignored If an alarm is enabled but masked the user can then decide to set it to be silent or message only 12 4 3 Title 12 4 6 is the title or name of the alarm just like giving a preset or tour a title this will be displayed on screen when the alarm ac
5. gt LOGIN gt MAIN MENU gt CAMERA SETTINGS gt DAY MODE SETTINGS gt ADV CONFIG gt BACKLIGHT COMPENSATION MOVE 4 gt TO SELECT ON OFF gt MOVE TO SAVE amp EXIT IMAGE STABILISER SONY MODULE gt LOGIN gt MAIN MENU gt CAMERA SETTINGS gt DAY MODE SETTINGS gt ADV CONFIG gt IMAGE STABILISER MOVE 4 v TO SELECT ON OFF gt MOVE 4 TO SAVE amp EXIT WHITE BALANCE LOGIN gt MAIN MENU gt CAMERA SETTINGS gt DAY MODE SETTINGS gt ADV CONFIG gt WHITE BALANCE MOVE 4 v TO SELECT OPTION gt MOVE TO SAVE amp EXIT NOISE REDUCTION PARKED gt LOGIN gt MAIN MENU gt CAMERA SETTINGS gt DAY MODE SETTINGS gt ADV CONFIG gt NOISE REDUCTION PARKED MOVE TO ADJUST 0 to 5 0 IS DEFAULT gt MOVE TO SAVE amp EXIT NOISE REDUCTION MOVING gt LOGIN gt MAIN MENU gt CAMERA SETTINGS gt DAY MODE SETTINGS gt ADV CONFIG gt NOISE REDUCTION MOVING MOVE lt v To ADJUST 0 to 5 2 is DEFAULT gt MOVE TO SAVE amp EXIT SPOT AE SONY MODULE LOGIN gt MAIN MENU gt CAMERA SETTINGS gt DAY MODE SETTINGS gt ADV CONFIG gt SPOT AE MOVE 4 v TO SELECT ON OFF gt MOVE TO SAVE amp EXIT APERTURE CORRECTION SONY MODULE LOGIN gt MAIN MENU gt CAMERA SETTINGS gt DAY MODE SETTINGS gt ADV CONFIG gt APERTURE CORRECTION MOVE lt v SELECT 1 to 16 9 IS DEFAULT gt MOVE lt TO SAVE amp EXIT GAIN LIMIT LOGIN gt MAIN MENU gt CAMERA SETTINGS gt
6. A message will display to confirm successful login or not Default PASSWORDS TECHNICIAN 999900 Full access SUPERVISOR 555500 partial access OPERATOR 111100 limited access To change a password see 6 4 5 4 amp view permissions rights see 6 4 5 LOGIN EXPIRY After 5 minutes of user inactivity the system times out and the Camera reverts to its previous activity Access to the menu will be denied unless password is re entered SET UP The SET UP is the main sub menu for accessing Camera configuration settings See 6 4 1 to 6 4 10 LOGIN gt MAIN MENU gt SET UP ENTER DATE amp TIME LOGIN gt MAIN MENU gt SETUP gt ENTER DATE TIME MOVE gt v TO SET DATE DD MM YY 8 TIME HH MM SS MOVE 4 TO SAVE amp EXIT eo ENTER DATE TIME DATE TIME POSITION 6 1 MENU NAVIGATION FLOW CHART DAYLIGHT SAVING CAMERA CAMERA TITLE SCREEN POSITION LANGUAGE SHOW PRESETS DURING TOURS DISPLAY PRESET TEXT POSITION LOG IN PASSWORDS TEXT BACKGROUND DATUM CHECK HANGING ARMS 0UT CAMERA ORIENTATION SET UP 4 UPRIGHT INSTALLATION DATE UPRIGHT ARMS OUT CLEAR SETTINGS CLEAR CONFIGURATION DIAGNOSTICS CLEAR PRESETS CLEAR TOURS Ci wove LEAR PRIVACY NIGHT MODE 7 SELECT NIGHT MODE c NIGHT MODE SWITCHING CLEAR ALARM SETTINGS ON LEVEL CLEAR EVERYTHING REBOOT SHUTTER SPEED EXPOSURE COMPENSATION JOYSTICK FOCUS MODE CAMERA SETTINGS s DAY MODE SETTINGS PRESET FOCUS MODE ADVANCED CONFIGURATION LOW
7. 2 7 3 7 4 7 5 SELECT NIGHT MODE IR Mode Low Light Mode gt LOGIN gt MAIN MENU gt NIGHT MODE gt SELECT NIGHT MODE gt MOVE TO SELECT EITHER IR MODE OR LOW LIGHT MODE MOVE 4 TO SAVE amp EXIT NIGHT MODE SWITCHING Light sensing Manual Timed LOGIN gt MAIN MENU gt NIGHT MODE gt NIGHT MODE SWITCHING gt MOVE TO SELECT EITHER LIGHT SENSING MANUAL OR TIMED MOVE 4 TO SAVE amp EXIT ON LEVEL Light level at which the camera switches to either IR mode or Low Light Mode Low light mode can be set to force camera to stay in colour or mono without infra red Default setting is 50 On Level must be lower than OFF level The lower the number the darker the light needs to be in order for the camera to switch to IR mode or Low Light Mode LOGIN gt MAIN MENU gt NIGHT MODE gt ON LEVEL MOVE CHANGE VALUE gt MOVE 4 TO SAVE amp EXIT TECH SUPPORT COMMENT The numerical value is an arbitrary figure and not a lux measurement OFF LEVEL Light level at which the camera switches to DAY MODE Colour gt LOGIN gt MAIN MENU gt NIGHT MODE gt OFF LEVEL MOVE CHANGE VALUE gt MOVE 4 TO SAVE amp EXIT AUTO SWITCH DELAY The AUTO SWITCH DELAY time can be set in seconds The delay prevents the IR pods amp Camera responding to short term effects e g car headlights which may cause the IR pods amp Camera to switch to mono gt LOGIN gt MAIN MENU gt NIGHT MODE gt AUTO SW
8. 5 3 6 4 5 4 6 4 6 X SERIES USER MANUAL TEXT BACKGROUND LOGIN gt MAIN MENU gt SETUP gt DISPLAY gt TEXT BACKGROUND MOVE SELECT TO CHANGE TEXT BACKGROUND MOVE 4 TO SAVE amp EXIT PASSWORDS LOGIN gt MAIN MENU gt SETUP gt PASSWORDS OPERATOR LIMITED ACCESS Default password is 111100 TO CHANGE see 6 4 5 4 Permission rights Date time Daylight saving Presets Tours Display options Language options Datum check SUPERVISOR PARTIAL ACCESS Default password is 555500 TO CHANGE see 6 4 5 4 Permission rights All operator permissions plus Clear privacy Set privacy Alarms TECHNICIAN FULL ACCESS Default password is 999900 TO CHANGE see 6 4 5 4 Permission rights All operator amp supervisor permissions plus Camera titles Set passwords Installation date Clear settings Reboot Diagnostics R modes Camera settings Joystick settings Wiper settings TO CHANGE PASSWORD LOGIN gt MAIN MENU gt SETUP gt PASSWORDS LOGIN USING TECHNICIAN PASSCODE MOVE 4 TO SELECT LEVEL TO BE CHANGED MOVE 4 TO CHANGE PASSWORD NUMBER MOVE 4 TO SAVE amp EXIT V v V v DATUM CHECK The Redvision X Series Camera is programmed to perform a datum check every 24 hours The Camera will pan and tilt for a few seconds while it undergoes a self diagnostic test and re checks its alignment When the process is complete the Camera will revert to its previous activity includin
9. 5 to set the Baud rate 0 off up amp 1 down See TABLE 3 below For Baud Rate settings refer to user manual for the control equipment being used NB Pelco D is normally 2400 Pelco P is 4800 Dennard is 9600 TABLE 3 ROW A DIP SWITCH BAUD 6 2g 7 9600 0 0 2400 1 0 4800 0 1 19200 de X SERIES USER MANUAL 2 5 SETTING THE CAMERA RS485 TERMINATION The default position is ON down TABLE 4 ROW A DIP SWITCH TERMINATION 2 3 4 5 6 7 8 OFF 0 ON 1 4 b CAUTION Termination switch should be set to ON down if The Camera is being run on coax protocol The Camera is the only one connected to the twisted pair The Camera is last one on a daisy chain An alarm module has been fitted to the Camera power supply amp is running 485 protocol The termination switch should be OFF up if More than one Camera is connected on a DAISY CHAIN but it is NOT the last in line The exception would be if an alarm module were installed If this were the case the Camera should be terminated ON DOWN and the alarm module would un terminated OFF UP see section 4 5 Setting the Alarm Module RS485 Termination 2 6 REAL TIME CLOCK RTC Row A switch 7 sets the Camera s internal real time clock The RTC is used for setting the cameras internal clock amp can be used for programming timed tours as well as RVX Series alarm functions if using RVX PSU ALM16 W The RTC battery can be s
10. DAY MODE SETTINGS gt ADV CONFIG gt GAIN LIMIT MOVE 4 TO CHANGE VALUE gt MOVE TO SAVE amp EXIT CHROMA CORRECTION HITACHI MODULE gt LOGIN gt MAIN MENU gt CAMERA SETTINGS gt DAY MODE SETTINGS gt CHROMA CORRECTION MOVE TO CHANGE VALUE gt MOVE 4 TO SAVE amp EXIT Bee 8 2 8 2 1 8 2 2 8 28 8 2 4 8 2 5 8 2 6 8 2 6 1 LOW LIGHT MODE SETTINGS ESERIES USER MANUAL The following settings apply when the camera switches from DAY MODE SETTINGS colour to NIGHT MODE gt LOW LIGHT MODE SETTINGS COLOUR MONO Select either COLOUR or MONO for when the camera switches to LOW LIGHT MODE SETTING In this mode on DAY to NIGHT change over the camera will be forced to stay in colour or mono without IR regardless of ambient light conditions TECH SUPPORT COMMENT In LOW LIGHT MODE setting the camera can be programmed to auto switch to IR ON MONO by using THE IRIS KEY or A PRESET NUMBER gt LOGIN gt MAIN MENU gt CAMERA SETTINGS gt NIGHT SETTINGS gt COLOUR MONO gt MOVE TO SELECT COLOUR OR MONO gt MOVE 4 TO SAVE amp EXIT SHUTTER SPEED The shutter speed can be slowed down to increase light sensitivity Default setting 1 25 gt LOGIN gt MAIN MENU gt CAMERA SETTINGS gt LOW LIGHT MODE SETTINGS gt SHUTTER SPEED gt MOVE TO CHANGE SHUTTER SPEED MOVE 4 TO SAVE amp EXIT EXPOSURE COMPENSATION Adjustment for unusual lighting distribution C
11. ENABLE SOLID DISABLE CLEAR MOVE 4 TO SAVE amp EXIT Note This is a global setting for monday through friday ACTIVE TIME WEEKENDS LOGIN gt MAIN MENU gt ALARMS gt EDIT ALARMS gt 1 16 gt ACTIVE TIME WEEKEND MOVE 4 TO SELECT HOUR TIME BLOCKS MOVE gt gt TO SELECT ENABLE SOLID DISABLE CLEAR MOVE 4 TO SAVE amp EXIT Note This is a global setting for saturday and sunday ACTION WHEN ACTIVE gt LOGIN gt MAIN MENU gt ALARMS gt EDIT ALARMS gt 1 16 gt ACTION WHEN ACTIVE MOVE gt gt TO SELECT GO TO PRESET MESSAGE ONLY SILENT OR RUN TOUR MOVE 4 TO SAVE amp EXIT ACTION NUMBER TECH SUPPORT COMMENT The Action Number is the number of the preset or tour to go depending on which option is selected gt LOGIN gt MAIN MENU gt ALARMS gt EDIT ALARMS gt 1 16 gt ACTION NUMBER gt MOVE TO SELECT NUMBER BETWEEN 1 100 MOVE 4 TO SAVE amp EXIT ACTION WHEN MASKED gt LOGIN gt MAIN MENU gt ALARMS gt EDIT ALARMS gt 1 16 gt ACTION WHEN MASKED MOVE TO SELECT GOTO MESSAGE ONLY OR SILENT gt MOVE 4 TO SAVE amp EXIT gt LOGIN gt MAIN MENU gt ALARMS gt EDIT ALARMS gt 1 16 gt TITLE MOVE 2 TO SELECT ALPHNUMERIC CHARACTERS MOVE 4 TO SAVE amp EXIT 12 4 7 12 4 8 12 4 9 X SERIES USER MANUAL NEW ALARM DWELL The Camera will move to a corresponding preset when a new alarm occurs On multiple alarms presets wil
12. MOVE gt gt TO SELECT A TOUR NUMBER 1 8 MOVE gt gt TO CHANGE VALUE MOVE lt TO SAVE amp EXIT TOUR TITLE HOW TO PROGRAM Each tour can be assigned its own title The default title is T1 T2 T3 etc gt LOGIN gt MAIN MENU gt PRESETS amp TOURS gt TOURS gt TOUR TITLES TOUR MOVE INPUT TITLE MOVE gt gt TO SELECT A TOUR NUMBER TO BE NAMED MOVE TO SELECT ALPHANUMERIC CHARACTERS MOVE 4 TO SAVE amp EXIT HOW TO INITIALISE A TOUR gt LOGIN gt MAIN MENU gt PRESETS amp TOURS gt TOURS gt INITIALISE TOUR MOVE TO SELECT EITHER CANCEL DOES NOTHING 8 LEAVES TOUR INTACT CLEAR REMOVES PRESETS FROM TOUR OR SET POPULATES THE TOUR WITH ALL SET PRESETS IN ORDER MOVE 4 TO SAVE amp EXIT EDIT TOUR Allows operator to edit the standard tour sequence e g preset 1 2 3 The default setting is position 1 of the tour preset 1 and position 2 preset 2 etc The tour can be edited so that position 1 could preset 2 for example any positions set to NO preset will be ignored when the tour is running TECH SUPPORT COMMENT Note that any positions set to empty presets will be skipped J gt LOGIN gt MAIN MENU gt PRESETS amp TOURS gt TOURS gt EDIT TOUR gt MOVE TO SELECT TOUR TO BE EDITED gt MOVE 4 TO SAVE amp EXIT eO 10 3 1 4 10 3 1 5 10 3 1 6 10 3 1 7 10 4 10 4 1 10 4 2 10 4 3 X SERIES USER MANUAL TOUR DWELL TIME T
13. TO SELECT OFF ACTIVE ALARMS NIGHT MODE MOVE 4 TO SAVE amp EXIT 9 9 9 COMPATIBILITY MODE usan MANUAL Use this function if ADPRO TELEPRECISION ABSOLUTE POSITIONING BBV1000 1500 Control Systems are being deployed All other systems select STANDARD gt LOGIN gt MAIN MENU gt JOYSTICK gt COM MODE MOVE TO SELECT CONTROL SYSTEM STD OR OFF MOVE 4 TO SAVE amp EXIT 10 PRESETS amp TOURS Presets and tours can be programmed using third party keyboard controllers or from the Camera s own internal menu To access presets amp tours menu gt LOGIN gt MAIN MENU gt PRESETS amp TOURS 10 1 FOCUS SHIFT gt TECH SUPPORT COMMENT Technicians will be familiar with setting up focus on a fixed camera by temporarily fitting the lens with a Neutral Density ND filter to compensate for focus shift when the camera switches to mono The best way to ensure optimum focus on THE REDVISION X SERIES PTZ Dome camera is to set night time presets when the light levels are low and the camera is in mono If using a PTZ fitted with IR the IR pods should be switched ON RVX IR versions only The controller s focus near focus far can be used to fine tune the focus manually before saving the preset This way the camera will remember the IR focus settings at an absolute focal length for that specific preset lt SSS SSS SSS 10 2 PRESET 10 2 1 SET A PRESET USING CAMERA INTERNAL M
14. WASH is activated by a wash command or by user defined preset AUX can be triggered by ACTIVE ALARMS or IR NIGHT MODE SWITCHING NORMALLY OPEN NORMALLY CLOSED ALARM INPUTS See S3 amp S4 on the RVX PSU ALM16 PCB see diagram FIG 8 page 8 DEM 3 NO NC ALARMS 1 8 54 NO NC ALARMS 9 16 TERMINATION SCENARIOS If control is over coax protocol both the Camera and Alarm Module should be terminated ee en n i 1 000 TERMINATED TERMINATED eot el p T i K DVR PR i RV DOME Toco PSU b 7 TERMINATED If control is over RS485 and the system is running a Star Card configuration both the Camera and Alarm Module should be terminated ccm m PSU amp ALARM QS uides nm TERMINATED lt lt e 8 DVR it RV DOME Rs 485 PSU 2 TERMINATED T 5 i If control is over RS485 the system is running Daisy Chain configuration then A If the Camera and Alarm Module is the last in line both the Camera and Alarm Module should be terminated X SERIES USER MANUAL RV DOME RV DOME RV DOME UN TERMINATED UN TERMINATED TERMINATED n WE cen Kn _RS 48 DAISY CHAIN 1 1 PSU amp PU PSU 7 ALARM MODULE 7 TERMINATED B If the Camera and Alarm Module is NOT the last in line the Camera should be terminated and the Alarm Module un Terminated The Alarm Module takes
15. gt TO SELECT OFF ON ON IS DEFAULT gt MOVE 4 TO SAVE 8 EXIT APERTURE CORRECTION SONY MODULE gt LOGIN gt MAIN MENU gt CAMERA SETTINGS gt LOW LIGHT MODE SETTINGS gt ADV CONFIG gt APERTURE CORRECTION MOVE TO SELECT 1 to 16 9 IS DEFAULT gt MOVE 4 TO SAVE amp EXIT 8 2 6 10 GAIN LIMIT LOGIN gt MAIN MENU gt CAMERA SETTINGS gt LOW LIGHT MODE SETTINGS gt ADV CONFIG gt GAIN LIMIT MOVE TO CHANGE VALUE MOVE 4 TO SAVE amp EXIT X SERIES USER MANUAL 8 3 IR MODE SETTINGS 8 3 1 FOCUS CORRECTION gt LOGIN gt MAIN MENU gt CAMERA SETTINGS gt IR MODE SETTINGS gt FOCUS CORRECTION gt MOVE TO SELECT ON OR OFF DEFAULT MOVE 4 TO SAVE amp EXIT TECH SUPPORT COMMENT For typical CCTV applications it is recommended to leave the setting to default OFF 8 3 2 SHUTTER SPEED The shutter speed can be slowed down to increase light sensitivity Default setting 1 25 gt LOGIN gt MAIN MENU gt CAMERA SETTINGS gt IR MODE SETTINGS gt SHUTTER SPEED MOVE TO CHANGE SHUTTER SPEED 1 12 to AUTO gt MOVE 4 TO SAVE amp EXIT 8 3 3 EXPOSURE COMPENSATION Adjustment for unusual lighting distribution Compensation can be either positive additional exposure or negative reduced exposure Default setting 0 gt LOGIN gt MAIN MENU gt CAMERA SETTINGS gt IR MODE SETTINGS gt EXPOSURE COMPENSATION MOVE gt gt TO ADJUST EXPOSURE LEVEL BETWEEN 7 AND 7 MOVE 4 T
16. over the termination from the Camera i e it the Alarm Module should be un terminated RV DOME RV DOME RV DOME RV DOME UN TERMINATED TERMINATED UN TERMINATED TERMINATED r RS 485 DVR DAISY CHAIN ENU EENE 4 PSU amp 1 1 PSU ALARMMODULE M PSU PSU UN TERMINATED 5 WIRELESS ALARM CARD WIRELESS PIR DETECTOR 5 1 FACTORY FITTED WIRELESS CARD RV PSU ALM16 W The Redvision Wireless Card is compatible with the Redvision Wireless PIR Luminite Genesis Range and the Redwall Wireless Transmitter Module Part Code WF434T wireless enables Redwall PIRs This PSU is compatible with the following RVX SERIES PTZs RVX18 RVX18 IR RVX18 W RVX18 IR W RVX28 RVX28 IR RVX28 W RVX28 IR W Refer to 4 2 for RVX PSU INTERNAL CONNECTIONS amp 4 3 for ALARM MODULE DIP SETTINGS 5 1 1 CONFIGURING WIRELESS ALARM MODULE ALARM INPUTS The RVX PSU ALM16 W has 16 Alarm Inputs These can either be used as either HARDWIRED or WIRELESS Alarm Inputs or a combination of both e g 8 HARDWIRED amp 8 WIRELESS Be 5 1 2 5 2 X SERIES USER MANUAL DIP SWITCH SETTINGS The WIRELESS Alarm Module has a single 8 Way DIP SWITCH See FIG 8 below 1 to 3 dip switches are not used amp should be left ON UP Switches 4 to 8 Dome Head Site Code provide up to 32 1 to SW1 16 shown in TABLE 19 channels of wireless transmission to 45 67 UP oc enable alarm activa
17. the setting selected in SELECT NIGHT MODE 7 1 10 2 2 3 10 2 3 10 3 10 3 1 10 3 1 1 10 3 1 2 10 3 1 3 X SERIES USER MANUAL CLEAR PRESET DELETES INDIVIDUAL PRESET amp CONTENT gt LOGIN gt MAIN MENU gt PRESETS amp TOURS gt PRESETS gt EDIT PRESETS MOVE TO SELECT PRESET NUMBER TO BE EDITED USE TO SELECT PRESET USE TO SELECT YES NO gt MOVE 4 TO SAVE amp EXIT PRESET SPEED The speed at which the Camera moves to each preset can be programmed Default is 60 To change the value gt LOGIN gt MAIN MENU gt PRESETS amp TOURS gt PRESETS gt PRESET SPEED gt MOVE TO SELECT PRESET MOVE TO CHANGE VALUE 10 TO 100 MOVE 4 TO SAVE amp EXIT TOURS Tour 1 by default is fully populated amp includes all set presets It is possible to program up to 100 presets per tour Once a tour is set the Camera moves between each preset within that tour automatically and will dwell 10 3 1 4 for a period specified The restore tour mode 10 4 4 can be activated on any tour from 1 to 8 The tour is continually repeated unless interrupted by Manual pan tilt or zoom Calling up a preset position An alarm activation TOUR 1108 The user can set up to 8 different tours Tour 1 by default is fully populated amp includes all set presets These can be edited if required All other tours are empty LOGIN gt MAIN MENU gt PRESETS 8 TOURS gt TOURS gt TOUR
18. 8x Optical 12x 12x 550TVL 550TVL 2 8 48 2 2 54 2 4 1 to 73 8mm F1 4 to F3 0 7 1x F1 4 50IRE FCB EX985 E P RVX28x Optical 3 5 91 0mm F1 6 to F3 8 0 25 1x F1 35 50IRE email web FCB EX1020 P RVX36x Optical 12x 550TVL 1 7 57 8 3 5 91 0mm F1 6 to F3 8 1 4 1x F1 6 50IRE X SERIES USER MANUAL 44 0 1420 448 448 support redvisioncctv com www redvisioncctv com support TELEMETRY RS485 Pelco P Pelco D Vista Dennard amp Bosch Coax BBV Addressing DIP switch Baud rate 2400 4800 9600 amp 19200 MECHANICAL Left amp Right Pan Limits Pan amp Tilt Programmable Continuous 360 Pan 0 1 200 per second Tilt 60 to 90 depending on set up INFRA RED ILLUMINATION RVX IR version KEY FEATURES IR wavelength IR range 850nm semi covert 940nm covert wavelength available to special order Tested to 100m 850nm Presets Tours Password protection 100 presets with programmable titles amp 8 tours with programmable titles Yes three levels Camera titles 16 alphanumeric characters ENVIRONMENTAL amp PHYSICAL Preset titles 16 alphanumeric characters Privacy zones 24 programmable Camera head material Die cast aluminium Alarm handling Weekend weekday time Window Flat toughened glass schedules for enabling disabling Operating temperature 35 C to 50 C heater Fan alarms Camera head Weight 6 5 Kilos Video launch amplifier 0 6dB 8 steps
19. BER BETWEEN 1 100 To activate wiper Press preset number To deactivate wiper Select same preset number WASH SHORTCUT PRESET If the control unit does not have a dedicated wiper key function it is possible to allocate a PRESET number to activate deactivate the wiper gt LOGIN gt MAIN MENU gt JOYSTICK gt JOYSTICK WIPER gt WASH SHORT CUT PRESET gt SELECT NO PRESET OR PRESET NUMBER BETWEEN 1 100 9 5 9 5 1 9 5 2 9 6 9 7 9 8 X SERIES USER MANUAL PAN LIMITS Program Camera to pan only within pre defined left and right limits This can be useful if the Camera is mounted on the corner of a building or a wall If presets are programmed the Camera will stay within the permitted limits and not take the shortest route gt LOGIN gt MAIN MENU gt JOYSTICK gt PAN LIMIT gt SET PAN LIMITS gt MOVE TO SELECT ON OFF MOVE 4 TO SAVE amp EXIT TECH SUPPORT COMMENT If re setting LEFT amp RIGHT PAN limits the technician should turn use limits off to allow full movement SET RIGHT LIMIT gt LOGIN gt MAIN MENU gt JOYSTICK gt PAN LIMIT gt SET RIGHT PAN LIMIT gt PAN THE CAMERA TO THE RIGHT MOST PAN LIMIT PRESS SELECT OR WAIT 10 SECS FOR AUTO SET gt MOVE 4 TO SAVE amp EXIT SET LEFT LIMIT gt LOGIN gt MAIN MENU gt JOYSTICK gt PAN LIMIT gt SET LEFT PAN LIMIT gt PAN THE CAMERA TO THE LEFT MOST PAN LIMIT PRESS SELECT OR WAIT 10 SECS FOR AUTO SET
20. CKS MOVE 2 TO SELECT ENABLE 1 9 DISABLE MOVE 4 TO SAVE amp EXIT Note This is a global setting for Monday through Friday TIMED RESTORE WEEKEND gt LOGIN gt MAIN MENU gt PRESETS amp TOURS gt RESTORE gt TIMED RESTORE WEEKEND MOVE 4 TO SELECT HOUR TIME BLOCKS MOVE TO SELECT ENABLE 1 9 DISABLE MOVE 4 TO SAVE amp EXIT Note This is a global setting for Saturday amp Sunday X SERIES USER MANUAL 1044 RESTORE MODE PRESETS amp TOURS Use this option to make the Camera revert to a tour or preset after a specified delay period in seconds of inactivity see RESTORE DELAY 10 4 5 Restore modes gt LOGIN gt MAIN MENU gt PRESETS amp TOURS gt RESTORE gt RESTORE MODE MOVE TO SELECT OFF FIXED TOUR FIXED PRESET TIMED TOUR TIMED PRESET MOVE 4 TO SAVE amp EXIT TECH SUPPORT COMMENT Can also use timed restore weekday weekend to restore To restore to a different tour at different times see 12 4 10 45 RESTORE DELAY PRESETS amp TOURS Time taken before presets or tours are restored Select between 5 180 seconds and OFF gt LOGIN gt MAIN MENU gt PRESETS amp TOURS gt RESTORE DELAY MOVE TO SELECT OFF or CHANGE VALUE IN SECONDS 5 180 MOVE 4 TO SAVE amp EXIT 11 PRIVACY ZONES Multiple privacy zones can be programmed TECH SUPPORT COMMENT Recommended privacy patch should be set 50 larger than object being masked
21. ENU LOGIN gt MAIN MENU gt PRESETS amp TOURS gt PRESETS gt SET PRESETS MOVE TO SELECT PRESET NUMBER BE SAVED 1 100 NUDGE JOYSTICK ARROW right TO PRODUCE COSSHAIR USE PTZ CONTROL TO MOVE CAMERA INTO POSITION USE ENTER OR CANCEL TO QUIT OR WAIT 10 SECS FOR PRESET TO AUTO SET REPEAT STEPS 4 TO 6 TO SET MORE PRESETS MOVE 4 TO SAVE amp EXIT v v Vv Vv v v V 10 2 2 EDIT PRESET The default display title for a preset is p1 p2 p3 etc TO CUSTOMISE preset titles A preset can be edited in three ways TITLE NIGHT MODE SWITCHING amp CLEAR PRESET 10 2 2 1 TITLE The default preset title p1 p2 etc can be renamed e g front door LOGIN gt MAIN MENU gt PRESETS amp TOURS gt PRESETS gt EDIT PRESETS MOVE TO SELECT PRESET NUMBER TO BE EDITED gt USE TO INPUT TITLE USE 2 TO SELECT ALPHANUMERIC CHARACTERS MOVE 4 TO SAVE amp EXIT 10 2 2 2 NIGHT MODE SWITCHING A preset can be programmed to switch to a different night mode setting e g infra red low light colour or mono with no infrared for example this may be useful if the camera is set to switch to low light colour mode at night but needs to automatically switch to ir mono in certain preset position gt LOGIN gt MAIN MENU gt PRESETS amp TOURS gt PRESETS gt EDIT PRESETS gt MOVE TO SELECT NIGHT MODE MOVE TO SELECT IR MODE LOW LIGHT MODE AUTO MOVE 4 TO SAVE amp EXIT qe NOTE Auto will default to
22. IGITAL ZOOM Select digital zoom if user wants zoom beyond optical zoom limit Default is off TECH SUPPORT COMMENT Picture degradation may occur at high zoom gt LOGIN gt MAIN MENU gt CAMERA SETTINGS gt DIGITAL ZOOM MOVE SELECT YES NO MOVE 4 TO SAVE amp EXIT INVERT CAMERA IMAGE TECH SUPPORT COMMENT Technicians should set the Camera orientation first see 6 4 7 INVERT CAMERA IMAGE function should only be used to correct for special cases once orientation has been set otherwise it should be set to NO gt LOGIN gt MAIN MENU gt CAMERA SETTINGS gt INVERT CAMERA IMAGE MOVE SELECT YES NO MOVE 4 TO SAVE amp EXIT MIRROR CAMERA IMAGE This function reverses the image e g left to right will appear right to left gt LOGIN gt MAIN MENU gt CAMERA SETTINGS gt MIRROR CAMERA IMAGE gt MOVE SELECT YES NO MOVE 4 TO SAVE amp EXIT CROSS HAIR gt LOGIN gt MAIN MENU gt CAMERA SETTINGS gt CROSS HAIR MOVE SELECT ON OFF MOVE 4 TO SAVE amp EXIT Be X SERIES USER MANUAL JOYSTICK amp WIPER 9 1 9 2 9 3 9 4 9 4 1 9 4 2 9 4 3 9 4 4 JOYSTICK CURVE There are three settings The following options describe how sensitive the joystick is to small movements Linear is most sensitive quasi linear and non linear allow for finer control at low speeds ramping up with larger movements Quasi linear is the default gt LOGIN gt MAIN MENU gt J
23. IP SWITCH SETTINGS PROTOCOL ALARM MODULE BAUD RATE ALARM MODULE RS485 TERMINATION ALARM MODULE ALARM INPUTS ALARM INPUTS GROUNDS ALARM RELAY OUTPUTS VOLT FREE NORMALLY OPEN CLOSED ALARM INPUTS TERMINATION SCENARIOS 5 WIRELESS ALARM CARD WIRELESS PIR DETECTOR 5 1 5 1 1 5 1 2 5 2 FACTORY FITTED WIRELESS CARD RVX PSU ALM16 W CONFIGURING WIRELESS ALARM MODULE POSITIONING OF RVX PSU ALM16 W IF RETRO FITTING WIRELESS ALARM RECEIVER X SERIES USER MANUAL 6 NAVIGATING THE MENUS 9 9 6 1 MENU NAVIGATION FLOW CHART 6 1 1 ACCESS MAIN MENU FROM 3RD PARTY CONTROLLERS 6 1 2 EXIT MENU 6 2 LOGIN 6 3 LOGIN EXPIRY 6 4 SET UP 6 4 1 ENTER DATE amp TIME CLOCK 6 4 2 DAYLIGHT SAVING 6 4 3 LANGUAGE OPTIONS 6 4 4 DISPLAY 6 4 5 PASSWORDS 6 4 6 DATUM CHECK 6 4 7 CAMERA ORIENTATION 6 4 8 DATE AND TIME OF INSTALLATION 6 4 9 CLEAR SETTINGS 6 4 10 DIAGNOSTICS 7 NIGHT MODE 7 1 SELECT NIGHT MODE 7 2 NIGHT MODE SWITCHING 7 3 ON LEVEL 7 4 OFF LEVEL 7 5 AUTO SWITCH DELAY 7 6 ON TIMES 7 7 INFRA RED POWER RVX IR VERSION 0NLY 8 CAMERA SETTINGS 8 1 DAY MODE SETTINGS 8 2 LOW LIGHT MODE SETTINGS 8 3 IR MODE SETTINGS 8 4 VIDEO GAIN 8 5 VIDEO LIFT 8 6 IRIS KEY USAGE 8 7 DIGITAL ZOOM 8 8 INVERT CAMERA IMAGE 8 9 CROSS HAIR 9 JOYSTICK amp WIPER 9 1 JOYSTICK CURVE 9 2 ZOOM RATIO 9 3 JOYSTICK SPEED 9 4 WIPER 9 4 1 INTERMITTENT WIPE 9 4 2 WIPER TIMEOUT 9 4 3 WIPE SHORTCUT PRESET 9 4 4 WASH SHORTCUT PRESET 9 5 PAN LIMIT
24. ITCH DELAY MOVE CHANGE VALUE 1 999 seconds MOVE 4 TO SAVE amp EXIT Solid block Infra red ON No Block Infra red OFF 7 6 7 7 TIMES X SERIES USER MANUAL The IR PODS RVX IR version amp Camera can be programmed to switch on off colour mono at pre determined times There are 24 block positions representing each hour of the day gt LOGIN gt MAIN MENU gt NIGHT MODE gt IR ON TIMES MOVE TO SELECT HOUR TIME BLOCKS gt MOVE 4 TO SAVE amp EXIT INFRA RED POWER RVX IR VERSION ONLY The infra red intensity can be varied Default is set to 100 gt LOGIN gt MAIN MENU gt NIGHT MODE gt IR POWER MOVE CHANGE VALUE gt MOVE 4 TO SAVE amp EXIT CAMERA SETTINGS 8 1 8 1 2 8 1 4 8 1 5 1 Use CAMERA SETTINGS to optimise the Sony module performance for specific day or night time conditions 1 Day Settings default day time colour amp IR PODS off RVX IR models see 8 1 2 Night Mode settings camera is either in IR Mode or Low Light Mode see 7 1 DAY MODE SETTINGS SHUTTER SPEED Adjust the shutter speed to achieve greater light sensitivity Default is 1 215 gt LOGIN gt MAIN MENU gt CAMERA SETTINGS gt DAY MODE SETTINGS gt SHUTTER SPEED MOVE TO CHANGE SHUTTER SPEED 1 1 to AUTO MOVE 4 TO SAVE amp EXIT EXPOSURE COMPENSATION Adjustment for unusual lighting distribution Compensation can be either positive additional exposure or nega
25. LIGHT MODE SETTINGS SHUTTER SPEED IR MODE SETTINGS EXPOSURE COMPENSATION JOYSTICK FOCUS MODE VIDEO GAIN PRESET FOCUS MODE ADVANCED CONFIGURATION VIDEO UIT IRIS KEY USAGE OFF FOCUS CORRECTION OFF SHUTTER SPEED DIGITAL ZOOM EXPOSURE COMPENSATION INVERT CAMERA IMAGE JOYSTICK FOCUS MODE MIRROR CAMERA IMAGE PRESET FOCUS MODE CROSS HAIR ADVANCED CONFIGURATION X SERIES USER MANUAL JOYSTICK WIPER PAN LIMITS INTERMITTENT TILT LIMITS WIPER TIME OUT SHORTCUTS WIPER WASH SHORTCUT PRESET WIPER SHORTCUT PRESET NIGHT MODE SHORTCUT PRESETS WASH SHORTCUT PRESET AUX RELAY FUNCTION COMPATIBILITY MODE STANDARD BBV TX1000 1500 SET PRESET EDIT PRESETS PRESETS amp TOURS 10 PRESET SPEED PRESET 2 INITIALISE TOUR TOURS TOURS 1 8 EDIT TOUR RESTORE DWEIL TOUR ORDER FREEZE FRAME DURING SEEK RESTORE TO NUMBER TIMED RESTORE WEEKDAY TIMED RESTORE WEEKEND PRIVACY 11 SET OR CLEAR MASK RESTORE MODE ZOOM THRESHOLD RESTORE DELAY EDIT MASK ACTIVE TIME WEEKDAY ALARMS 12 ACTIVE TIME WEEKENDS ACTION WHEN ACTIVE ENABLE ALARMS ACTION NUMBER ALARM OVERRIDE TIME ACTION WHEN MASKED ALARM CYCLE TIME TITLE NEW ALARM DWELL EDIT ALARM SHOW ALARM INFO CLEAR COUNTERS 6 4 2 6 4 3 6 4 4 6 4 4 1 6 4 4 2 6 4 4 3 6 4 4 4 6 4 4 5 X SERIES USER MANUAL DAYLIGHT SAVING Default setting is AUTO gt LOGIN gt MAIN MENU gt SETUP gt DAYLIGHT SAVING MO
26. LOGIN gt MAIN MENU gt SETUP gt CLEAR SETTINGS gt CLEAR TOURS MOVE TO SELECT YES NO MOVE 4 TO SAVE amp EXIT CLEAR PRIVACY MASKS Use this option to clear ALL privacy masks LOGIN gt MAIN MENU gt SETUP gt CLEAR SETTINGS gt CLEAR PRIVACY MASKS gt MOVE TO SELECT YES NO gt MOVE 4 TO SAVE amp EXIT CLEAR ALARM SETTINGS LOGIN gt MAIN MENU gt SETUP gt CLEAR SETTINGS gt CLEAR ALARM SETTINGS gt MOVE TO SELECT YES NO gt MOVE 4 TO SAVE amp EXIT CLEAR EVERYTHING This option clears ALL settings but does not reboot the camera therefore leaving video picture LOGIN gt MAIN MENU gt SETUP gt CLEAR SETTINGS gt CLEAR EVERYTHING MOVE TO SELECT YES NO MOVE 4 TO SAVE amp EXIT REBOOT To soft restart the camera equivalent to power cycling LOGIN gt MAIN MENU gt SETUP gt CLEAR SETTINGS gt REBOOT gt MOVE TO SELECT YES NO gt MOVE 4 TO SAVE amp EXIT 6 4 10 X SERIES USER MANUAL DIAGNOSTICS There are five diagnostic screens which display useful information for the technician and remote help diagnostics for Redvision s technical support helpdesk They are not configurable To access the diagnostic screens LOGIN gt MAIN MENU gt SETUP gt DIAGNOSTICS MOVE gt gt TO SELECT SYSTEM STATUS CAMERA TELEMETRY OR MOTORS MOVE 4 TO SAVE 8 EXIT To exit motors it is necessary to recall the menu see 6 1 1 7 NIGHT MODE 7 1 7
27. O SAVE amp EXIT 8 3 4 JOYSTICK FOCUS MODE There are two settings AUTO focus amp MANUAL focus Default setting for NIGHT is AUTO gt LOGIN gt MAIN MENU gt CAMERA SETTINGS gt IR MODE SETTINGS gt JOYSTICK FOCUS MODE MOVE TO SELECT AUTO OR MANUAL MOVE 4 TO SAVE amp EXIT 8 3 5 PRESET FOCUS MODE SONY MODULE There are two modes AUTO amp STORED Default setting for NIGHT is STORED gt LOGIN gt MAIN MENU gt CAMERA SETTINGS gt IR MODE SETTINGS gt PRESET FOCUS MODE MOVE TO SELECT AUTO OR STORED gt MOVE 4 TO SAVE amp EXIT 8 3 6 ADVANCED CONFIGURATION LOGIN gt MAIN MENU gt CAMERA SETTINGS gt IR MODE SETTINGS gt ADVANCED CONFIGURATION 8 3 6 1 ZOOM LIMIT SONY MODULE This can be adjusted from 10 to 100 gt LOGIN gt MAIN MENU gt CAMERA SETTINGS gt IR MODE SETTINGS gt ADV CONFIG gt ZOOM LIMIT gt MOVE TO ADJUST ZOOM LIMIT BETWEEN 10 and 100 MOVE 4 TO SAVE amp EXIT 8 3 6 2 BACKLIGHT COMPENSATION The ability of a Camera to compensate in cases where a subject with a large amount of background light would otherwise be obscured by blooming or silhouetting gt LOGIN gt MAIN MENU gt CAMERA SETTINGS gt IR MODE SETTINGS gt ADV CONFIG gt BACKLIGHT COMPENSATION MOVE gt TO SELECT ON OFF gt MOVE TO SAVE amp EXIT 8 3 6 3 8 3 6 4 8 3 6 5 8 3 6 6 8 3 6 7 8 3 6 8 8 3 6 9 8 3 6 10 8 4 X SERIES USER MANUAL IMAGE STABILI
28. OT SWAP WIRELESS ALARM MODULE B Align Wireless Alarm Module with P3 Connector and secure with M3 fixings E Thread aerial antenna through gland and connect to BNC on Wireless Receiver F See Table 19 5 1 1 for DIP switch settings qe X SERIES USER MANUAL 6 NAVIGATING THE MENUS 6 1 6 1 1 6 1 2 6 2 6 3 6 4 6 4 1 MENU NAVIGATION FLOW CHART Use joystick Arrow keys to navigate the menu options See FIG 9 page 15 ACCESS MAIN MENU FROM 3rd PARTY CONTROLLERS As most keyboards differ in the way they access the Camera s MAIN MENU it is recommended the user refers to the specific keyboard manual for the control system they are using See Table 20 below for examples Some common examples for accessing the Camera main menu and commands are as follows TABLE 20 CONTROLLER ACCESS MAIN CAMERA MENU BBV Press amp hold then press 1 DTX400 Press amp hold SHIFT then press 1 BBV 1000 Press hold then press wash key DTX 1000 Press amp hold then wash key Save 95 Preset EXIT MENU Move the joystick or arrow keys to the left from all levels to exit the Camera main menu Any changes made will be saved permanently when the menu is exited The message SAVED OK will appear to confirm changes have been saved LOGIN Use joystick Arrow keys to navigate the menu options gt From main menu move joystick arrow TO LOGIN MENU MOVE 4 gt ENTER DIGIT PASSWORD MOVE 4 TO SAVE amp EXIT
29. OYSTICK gt JOYSTICK CURVE MOVE TO SELECT QUASI LINEAR LINEAR OR NON LINEAR gt MOVE 4 TO SAVE amp EXIT ZOOM RATIO The zoom ratio affects how much the Camera slows down as you zoom in the higher the numbers make the speed drop off more as you zoom in The default setting is 16 gt LOGIN gt MAIN MENU gt JOYSTICK gt ZOOM RATIO MOVE lt 8 16 32 64 MOVE 4 TO SAVE amp EXIT JOYSTICK SPEED Default setting is 60 Use gt to increase decrease LOGIN gt MAIN MENU gt JOYSTICK gt JOYSTICK SPEED MOVE INCREASE DECREASE SPEED SETTING MOVE 4 TO SAVE amp EXIT WIPER Applies to RVX models fitted with wiper LOGIN gt MAIN MENU gt JOYSTICK gt WIPER MOVE INTERMITTENT WIPE 1 99 OR WIPER TIMEOUT 1 255 MOVE TO CHANGE TIME IN SECONDS WIPE 1 99 TIMEOUT 1 255 gt MOVE 4 TO SAVE amp EXIT INTERMITTENT WIPE LOGIN gt MAIN MENU gt JOYSTICK gt WIPER gt INTERMITTENT WIPE gt WIPER SHORT CUT PRESET gt TO SELECT 1 99 SECS WIPER TIMEOUT gt LOGIN gt MAIN MENU gt JOYSTICK gt WIPER gt WIPER TIMEOUT gt WIPER SHORT CUT PRESET gt TO SELECT 1 255 MINS WIPER SHORT CUT PRESET If the control unit does not have a dedicated wiper key function it is possible to allocate a PRESET number to activate deactivate the wiper LOGIN gt MAIN MENU gt JOYSTICK gt WIPER gt WIPER SHORTCUT PRESET gt WIPER SHORT CUT PRESET gt SELECT NO PRESET OR PRESET NUM
30. Paint finish Powder coat Heater Yes IP Rating IP66 Fan Yes WIPER Optionally available on all models OPTIONAL ALARM MODULE Intermittent and Wiper Time Out Features 16 Alarm inputs volt free 1 relay fits to RV PSU Optional wireless card up to 16 PIRs POWER CONSUMPTION MOUNTING BRACKETS Input 110V to 240Vac 50MZ Type Pedestal Swan pedestal tower Output 24V DC 2A output mount wall corner pendant amp Power Consumption 2 Amps at 48VA pole clamp This product is marked and has been fully tested and complies with 2004 108 eec Electromagnetic Compatibility 73 23 eec Low Voltage Directives 60950 2006 Safety Standards 15 WARRANTY INFORMATION xv US rim Redvision CCTV Limited Redvision warrants the buyer that the product will on the date of shipment be free from defects in material amp workmanship and will conform to Redvision s specifications provided to the buyer If any defect in material or workmanship appears in the product Redvision will at its option either repair or replace the defective product without charge at Redvision s customer service centre or serviced authorised repair facility or credit or refund the purchase price of the defective product provided The defect appears within 24 months from the date of purchase by the end user Examination of the product confirms that the claimed defect actually exists Buyer shall follow Redvision s instructions regarding return of the defective prod
31. S 9 6 TILT LIMITS 9 7 SHORTCUTS 9 8 AUX RELAY FUNCTIONS COMPATIBILITY MODE X SERIES USER MANUAL 10 PRESETS amp TOURS 10 1 10 2 10 2 1 10 2 2 10 2 3 10 3 10 3 1 10 4 10 4 1 10 4 2 10 4 3 10 4 4 10 4 5 FOCUS SHIFT PRESET SET A PRESET USING CAMERA INTERNAL MENU EDIT PRESET PRESET SPEED TOURS TOUR 1 TO 8 RESTORE PRESETS AND TOURS RESTORE TO NUMBER EITHER TOUR OR PRESET NUMBER TIMED RESTORE WEEKDAY TIMED RESTORE WEEKEND RESTORE MODE PRESETS amp TOURS RESTORE DELAY PRESETS amp TOURS 11 PRIVACY ZONES 11 1 11 2 11 3 SET CLEAR MASK ZOOM THRESHOLD EDIT MASK 12 ALARM HANDLING IN MENU SOFTWARE 12 1 12 2 12 3 12 4 12 4 1 12 4 2 12 4 3 12 4 4 12 4 5 12 4 6 12 4 7 12 4 8 12 4 9 ENABLE DISABLE ALARMS ALARM OVER RIDE ALARM CYCLE TIME EDIT ALARMS ACTIVE TIME WEEKDAYS ACTIVE TIME WEEKENDS ACTION WHEN ACTIVE ACTION NUMBER ACTION WHEN MASKED TITLE NEW ALARM DWELL SHOW ALARM INFO CLEAR COUNTERS 13 CONTACT TECHNICAL SUPPORT 14 TECHNICAL SPECIFICATION 15 WARRANTY INFORMATION X SERIES USER MANUAL X SERIES USER MANUAL NOTES 1 INSTALLING THE CAMERA HEAD 1 1 1 2 X SERIES USER MANUAL CONVERT DOME TO BALL PTZ CONFIGURATION The RVX Series can be mounted as a dome or ball PTZ configuration To convert the dome to ball PTZ remove the M4 button head scre
32. SER SONY MODULE gt LOGIN gt MAIN MENU gt CAMERA SETTINGS gt IR MODE SETTINGS gt ADV CONFIG gt IMAGE STABILISER MOVE a TO SELECT ON OFF gt MOVE TO SAVE amp EXIT WHITE BALANCE LOGIN gt MAIN MENU gt CAMERA SETTINGS gt IR MODE SETTINGS gt ADV CONFIG gt WHITE BALANCE MOVE gt gt SELECT OUTDOOR AUTO ATW OUTDOOR INDOOR AUTO SODIUM LAMP SODIUM LAMP AUTO gt MOVE 4 TO SAVE 8 EXIT WIDE DYNAMIC RANGE LOGIN gt MAIN MENU gt CAMERA SETTINGS gt IR MODE SETTINGS gt ADV CONFIG gt WIDE DYNAMIC RANGE MOVE gt TO SELECT OFF AUTO ON MOVE lt TO SAVE amp EXIT NOISE REDUCTION PARKED gt LOGIN gt MAIN MENU gt CAMERA SETTINGS gt IR MODE SETTINGS gt ADV CONFIG gt NOISE REDUCTION PARKED MOVE gt TO ADJUST 0 to 5 0 IS DEFAULT gt MOVE 4 TO SAVE amp EXIT NOISE REDUCTION MOVING gt LOGIN gt MAIN MENU gt CAMERA SETTINGS gt IR MODE SETTINGS gt ADV CONFIG gt NOISE REDUCTION MOVING MOVE gt TO ADJUST 0 to 5 2 IS DEFAULT gt MOVE 4 TO SAVE amp EXIT SPOT AE SONY MODULE LOGIN gt MAIN MENU gt CAMERA SETTINGS gt IR MODE SETTINGS gt ADV CONFIG gt SPOT AE MOVE 4 TO SELECT OFF ON ON IS DEFAULT gt MOVE 4 TO SAVE amp EXIT APERTURE CORRECTION SONY MODULE LOGIN gt MAIN MENU gt CAMERA SETTINGS gt IR MODE SETTINGS gt ADV CONFIG gt APERTURE CORRECTION MOVE gt TO SELECT 1 to 16 9 IS DEFAULT MOVE lt TO SAVE amp E
33. VE 4 v TO SET AUTO OFF 0 ON 1 gt MOVE 4 TO SAVE amp EXIT LANGUAGE OPTIONS Localise the display messages into the following language options English Spanish German French Portuguese LOGIN USING TECHNICIAN PASSCODE gt MAIN MENU gt LANGUAGES MOVE TO CHANGE LANGUAGE MOVE 4 TO SAVE amp EXIT DISPLAY DATE TIME POSITION User has the option of inserting the on screen position of the date time LOGIN gt MAIN MENU gt SETUP gt DISPLAY gt DATE amp TIME POSITION MOVE 2 TO MOVE THE DISPLAY POSITION MOVE 4 TO SAVE amp EXIT Default is OFF nothing displayed CAMERA TITLE LOGIN gt MAIN MENU gt SETUP gt DISPLAY gt CAMERA TITLE gt TITLE MOVE a TO CHANGE ALPHANUMERIC CHARACTERS MOVE 4 TO SAVE 8 EXIT CAMERA TITLE SCREEN POSTION LOGIN gt MAIN MENU gt SETUP gt DISPLAY gt CAMERA TITLE gt POSITION ON SCREEN MOVE 2 TO MOVE SCREEN POSITION MOVE 4 TO SAVE amp EXIT SHOW PRESET TITLES DURING TOURS LOGIN gt MAIN MENU gt SETUP gt DISPLAY gt SHOW PRESET TITLE DURING TOURS MOVE SELECT YES NO MOVE 4 TO SAVE amp EXIT PRESET TEXT POSITION LOGIN gt MAIN MENU gt SETUP gt DISPLAY gt SHOW PRESET TEXT POSITION MOVE TO CHANGE POSITION MOVE 4 TO SAVE amp EXIT TECH SUPPORT COMMENT It is important users do not set everything to the same corner of the screen 09207 6 4 4 6 6 4 5 6 4 5 1 6 4 5 2 6 4
34. XIT GAIN LIMIT gt LOGIN gt MAIN MENU gt CAMERA SETTINGS gt IR MODE SETTINGS gt ADV CONFIG gt GAIN LIMIT gt MOVE gt TO CHANGE VALUE gt MOVE 4 TO SAVE 8 EXIT VIDEO GAIN Video gain can be set from 0 to 7db to compensate for losses in long cable runs Default setting is 2 TECH SUPPORT COMMENT It is recommended to use video lift first before adding gain as this will usually give better results LOGIN gt MAIN MENU gt CAMERA SETTINGS gt VIDEO GAIN MOVE v TO ADJUST from 0 7 gt MOVE 4 TO SAVE amp EXIT qe 8 5 8 6 8 7 8 8 8 9 8 10 VIDEO LIFT X SERIES USER MANUAL High frequency video lift can be set between 0 amp 8 Default is zero TECH SUPPORT COMMENT Technician should attempt to compensate for poor cable runs using video lift before using video gain gt LOGIN gt MAIN MENU gt CAMERA SETTINGS gt VIDEO LIFT gt MOVE TO ADJUST BETWEEN 0 8 MOVE 4 TO SAVE amp EXIT IRIS KEY USAGE The iris key can be assigned to either Adjust exposure compensation brighten darken image Shutter speed allows integration amp can only be adjusted when the camera is in NIGHT mode Night Mode Switching switches between IR mode amp Night Mode Low Light Setting gt LOGIN gt MAIN MENU gt CAMERA SETTINGS gt IRIS KEY USAGE MOVE gt gt TO SELECT EXPOSURE COMPENSATION SHUTTER SPEED NIGHT MODE SWITCHING OR OFF MOVE 4 TO SAVE amp EXIT D
35. a 2 way terminal block EARTH GREEN YELLOW Connection via terminal screw NOTE Earth connection requires 4mm red spade loop supplied with PSU to be fitted by engineer at installation SAFETY ENSURE MAINS INPUT amp EARTH CONNECTIONS ARE SECURELY STRAIN RELIEVED 90 3 3 2 CONNECTIONS CAMERA 8 WAY TERMINAL BLOCK TABLE7 PCBIDENT UMBILICAL LEAD TO CAMERA N C Normally Closed N C Normally Closed VIDEO Coax signal BNC 7 V GND Coax screen RS485 A White RS485 B Orange 24V Red ov Black and cable screen 3 3 3 CONNECTIONS TO CONTROL 8 WAY TERMINAL BLOCK TABLE 8 PCBIDENT CONTROL CONNECTIONS AUX C AUX E Not used VIDEO COAX signal BNC P6 V GND COAX screen RS485 A RS485 A RS485 B RS485 B 24V ov 3 3 4 RS485 DIAGNOSTIC LEDs TABLE 9 STATUS DESCRIPTION RED OFF GREEN OFF DISCONNECTED RED OFF GREEN ON OK IDLE RED FLASH GREEN FLASH OK TRAFFIC PASSING RED ON GREEN ON A B REVERSED 3 3 5 FUSE PROTECTION TABLE 10 PCB IDENT DESCRIPTION Mains input fuse 3 15A Anti Surge Camera fuse 3 15A Fast Blow X SERIES USER MANUAL X SERIES USER MANUAL FIG 8 METAL COVER CONTROL amp CONNECTIONS ALARM INPUTS DOME CONNECTIONS EARTH TERMINAL ALARM OUTPUTS 3 84 CONFIG DIP SWITCH 5 r is i 4 RVX PSU ALM16 PSU WITH ALARM MODULE 4 1 4 2 VOLTAGE Input 100 230V 47 63Hz 80VA MAX Output 24Vdc 2
36. e SET UP MENU select either UPRIGHT ARMS OUT or HANGING ARMS OUT RK Wh Canter Arms Forward Allen Screws X SERIES USER MANUAL 2 HOW TO CONFIGURE THE CAMERA 2 1 REMOVING THE DIP SWITCH SCREW COVER There are two rows of DIP switches located behind the large screw cap see FIG 1 below Use flat bladed screw driver to remove by turning anti clockwise to unscrew 2 1 1 CAMERA ORIENTATION FOR SETTING DIP SWITCHES CAUTION Make sure the dip switches read right way up before configuring Camera The word protocol should be displayed as per picture see FIG 2 below ON is down away from the word protocol gt OFF is up toward the word protocol The switch numbers read 1 to 8 from left to right THE BAUD amp PROTOCOL SWITCHES ROW A WORK AS FOLLOWS SWITCH 1 2 3 PROTOCOL SEE 2 3 SWITCH 4 amp 5 BAUD RATE 2 4 SWITCH 6 NOT USED SWITCH 7 REAL TIME CLOCK RTC BATTERY ENABLE 2 6 SWITCH 8 RS485 TERMINATION ENABLE 2 5 Use row B FIG 2 below to set the Camera address 2 2 FIG 2 BEFORE SETTING DIP SWITCHES ENSURE PROTOCOL READS THIS WAY UP SEE SAMPLE BAUD PROTOCOLTASST CAMERA ADDRESS LEM 2 1 2 DEFAULT DIP SWITCH SETTINGS All X series cameras are factory defaulted to the following configuration BBV Up The Coax UTC Camera address set to 1 RS485 terminat
37. ect accident or abuse To the unauthorised repair or alteration by anyone other than Redvision To improper installation storage or maintenance by anyone other than Redvision To product used in material violation of Redvision s instruction or To product which has had its serial numbers or month and year of manufacture or shipment removed defaced or altered or To software The term software means a set of logical instructions and table of information which guide the functioning of a processor Such set may be contained in any medium whatsoever including without limitation hardware containing a pattern of bits representing such set provided however the term software does not mean or include the medium Redvision shall charge for the repair of all product returned out of warranty call Redvision Customer Service 44 0 1420 448 448 for an RMA number or visit www redvisioncctv com for more information Due to a policy of continuous product development the content of this manual may change without notice Redvision CCTV Limited will endeavour to ensure the latest version is made available through the download section on its website www redvisioncctv com Copyright 2008 2011 Redvision CCTV Limited All rights reserved Redvision CCTV the Redvision Logo Redvision X series RV Camera Series Redzone IR Illuminator are trademarks or registered trademarks of Redvision CCTV Limited Redvision CCTV Limited 17 Highvie
38. et to ON either at commissioning or installation stage The default position is OFF UP TABLE 5 ROW DIP SWITCH 2 3 4 6 7 8 RTC OFF 0 ON 1 2 7 REPLACING THE DIP SWITCH COVER Before replacing the DIP switch screw cap it is important to check it is free of dirt and grit Thread contamination could affect the waterproof seal The thread should be carefully aligned to prevent burring Using a large flat bladed screw driver turn the screw CLOCKWISE to tighten X SERIES USER MANUAL 3 POWER SUPPLY INSTALLATION amp SETUP 3 1 3 2 3 3 3 3 1 AY see Camera Warranty is void unless it is installed using one of the following Redvision power supplies and a Redvision supplied fly lead Composite cable Using the wrong type of 3rd party PSU could compromise safety and damage the camera unit e RVX PSU RVX PSU ALM16 RVX PSU ALAM16 W The RVX Power Supplies are compatible with the following X Series Cameras RVX18 RVX18 W RVX18 IR RVX18 IR W RVX28 RVX28 W RVX28 IR RVX28 IR W COMPOSITE CABLE A pre made composite cable with a 7 way female amphenol connector is supplied with all Redvision brackets The female connector connects directly to the male connector on the RVX PTZ Camera housing Follow the colour coding idents as shown in table 3 2 2 for terminating the fly lead in the power supply CABLE CABLE WIRE TABLE The Redvision power supply part code RVX PSU output
39. g any tours with presets TECH SUPPORT COMMENT It is recommended to leave the Camera in the default 24 hour option BO 6 47 6 4 8 6 4 9 6 4 9 1 6 4 9 2 6 4 9 3 6 4 9 4 6 4 9 5 6 4 9 6 6 4 9 7 X SERIES USER MANUAL CAMERA ORIENTATION The Camera orientation automatically sets the maximum tilt up down positions depending on whether the Camera is in upright or hanging down mode The maximum tilt restrictions can be deactivated to allow full tilt movement See 9 6 gt LOGIN gt MAIN MENU gt SETUP gt CAMERA ORIENTATION MOVE gt gt TO SELECT CAMERA ORIENTATION gt HANGING HANGING ARMS OUT UPRIGHT UPRIGHT ARMS OUT gt MOVE 4 TO SAVE amp EXIT DATE AND TIME OF INSTALLATION LOGIN gt MAIN MENU gt SETUP gt INSTALLATION DATE MOVE 4 v TO ENTER INSTALLATION DATE TIME gt MOVE 4 TO SAVE amp EXIT CLEAR SETTINGS CLEAR CONFIGURATION Use this option to partially clear configuration settings All configuration changes except for tours and presets will be reset to factory default LOGIN gt MAIN MENU gt SETUP gt CLEAR SETTINGS gt CLEAR CONFIGURATION MOVE TO SELECT YES NO gt MOVE 4 TO SAVE amp EXIT CLEAR PRESETS Use this option to clear ALL stored presets gt LOGIN gt MAIN MENU gt SETUP gt CLEAR SETTINGS gt CLEAR PRESETS gt MOVE TO SELECT YES NO gt MOVE 4 TO SAVE amp EXIT CLEAR TOURS Use this option to clear ALL stored tours
40. he time the Camera dwells between each preset can be programmed between 1 amp 120 seconds Default is 8 seconds gt LOGIN gt MAIN MENU gt PRESETS amp TOURS gt TOURS gt DWELL gt MOVE TO SELECT DWELL TIME IN SECONDS MOVE 4 TO SAVE amp EXIT SPEED The speed at which the Camera moves to each preset Programmed in seconds gt LOGIN gt MAIN MENU gt PRESETS amp TOURS gt TOURS gt SPEED MOVE TO SELECT SPEED IN SECONDS MOVE 4 TO SAVE amp EXIT TOUR ORDER The speed at which the Camera moves to each preset Programmed in seconds gt LOGIN gt MAIN MENU gt PRESETS amp TOURS gt TOURS gt TOUR ORDER gt MOVE TO SELECT STANDARD 1 2 3 PING PONG 1 2 3 3 2 1 RANDOM MOVE 4 TO SAVE amp EXIT FREEZE FRAME DURING SEEK Freezes the last preset image until Camera moves to next preset image gt LOGIN gt MAIN MENU gt PRESETS amp TOURS gt TOURS gt FREEZE FRAME MOVE TO SELECT FREEZE FRAME gt MOVE 4 TO SAVE amp EXIT RESTORE PRESETS amp TOURS RESTORE TO NUMBER EITHER TOUR NUMBER OR PRESET NUMBER gt LOGIN gt MAIN MENU gt PRESETS amp TOURS gt RESTORE gt RESTORE TO NUMBER gt MOVE TO SELECT NUMBER 1 TO 100 IF ASSIGNING PRESET NUMBER 1 TO 8 IF ASSIGNING TOUR NUMBER MOVE 4 TO SAVE amp EXIT TIMED RESTORE WEEKDAY gt LOGIN gt MAIN MENU gt PRESETS amp TOURS gt RESTORE gt TIMED RESTORE WEEKDAY MOVE 4 TO SELECT HOUR TIME BLO
41. ion set to ON Real time clock set to OFF X SERIES USER MANUAL SETTING THE CAMERA ADDRESS See table TABLE 1 below for guidance on DIP switch setting for each Camera address 0 represents OFF up and 1 represents ON down TABLE 1 ROW B DIP SWITCH ROW B DIP SWITCH ADDRESS 1 2 3 4 5 6 7 8 ARMES 1 2 3 45 67 8 not used 0 0 0 0 0 0 0 16 0 0 0 0 1 0 0 0 1 1 0 0 00 0 0 0 17 1 0 0 0 1 Q 0 0 2 0 1 0 0 0 0 0 0 18 0 16 0 1 0 0 0 3 1 1 0 0 0 0 0 19 1 t 0 0 1 0 0 Q0 4 0 01 0090 0 0 20 0 0 7 0 0 0 5 1 0 1 0 0 0 0 0 2 1 0 0 1 0 0 0 6 0 1 1 0 0 0 0 0 22 0 1 1 0 10 0 0 7 14 1 0 0 0 0 0 23 1 1 7 0 1 0 0 0 8 0 0 0 1 0 0 0 24 0 D O 0 0 O 9 10 0 1 0 O 0 25 1 00 11 0 0 0 10 0 1 01 0 0 0 0 26 0 1 0 1 1 o 0 0 id Q1 1 0 1 0 0 0 0 27 1 1 0 1 1 0 0 0 12 0 0 1 1 0 0 0 28 0 0 1 9 0 00 13 1 0 1 7 60 O0 6 29 1 0 T7 1 1 0 0 0 14 6 1 1 1 9 0 0 0 30 0 1 1 1 1 0 0 0 15 1 1 1 1 0 0 0 0 31 1 43 17 1 17 0 0 2 See www redvisioncctv com support downloads for camera address 32 to 255 SETTING THE CAMERA PROTOCOL On row A Set DIP switch numbers 1 2 and 3 See TABLE 2 below 1 represents ON down and 0 represents OFF up TABLE 2 ROW A DIP SWITCH i 8 PROTOCOL BBV Up the Coax Pelco P Pelco D Dennard Vista Bosch BBV422 O a CO SETTING THE CAMERA BAUD RATE row A Use DIP switch numbers 4 and
42. is important and should match the picture in FIG C amp D below i e The Flat Edge should be positioned to the rear and the Retaining Lugs engaged in the Boss Cut Outs 4 If RV PED Pedestal is being used support the Camera with hand when tightening the Hand Lock Nut ensure the Hand Lock Nut is fully tightened 8 5 Ensure the Clearance is even throughout 360 rotation and the Camera is free moving 6 Replace Mount Cover Plates Retaining Lugs Mounting BaSS Mounting Boss Flat Edge 1 3 BRACKET TYPES RV SWAN Swan mount RV WALL Wall mount RV PNDT Pendant mount RV PED Pedestal for mast tower mount TECH SUPPORT COMMENT It is important to match the menu software settings to the Camera orientation 6 4 7 i e is the Camera hanging down or upright hanging down would be using one of the following bracket types swan RV SWAN pendant RV PNDT or wall RV WALL NOT SUITABLE FOR UPRIGHT MOUNTING Upright would be using the pedestal bracket RV PED 1 4 HOW TO CANTILEVER BALL PTZ ARMS FORWARD 1 Remove pear shaped badge on each arm using small flat head screw driver Slightly loosen by one turn BUT DO NOT REMOVE the allen screws Cantilever the Ball Arms forward to STOP position Tighten allen screws Replace badges spares are provided See Section 6 4 7 and from th
43. l be called up in sequence the dwell time in seconds between each alarm can be programmed Default is 5 seconds This function will be ignored if alarms are connected directly to third party control equipment rather than the Redvision alarm module TECH SUPPORT COMMENT See ALARM OVER RIDE 12 2 and ALARM CYCLE TIME 12 3 the new alarm dwell defines how long the Camera will stay on a new alarm when cycling through the active alarms list gt LOGIN gt MAIN MENU gt ALARMS gt EDIT ALARMS gt 1 16 gt NEW ALARM DWELL TIME MOVE TO CHANGE VALUE BETWEEN 1 20 SECONDS MOVE 4 TO SAVE amp EXIT SHOW ALARM INFO TECH SUPPORT COMMENT ALSO INCLUDES NUMBER OF ACTIVATIONS WHICH COULD BE USEFUL FOR TRACKING DOWN CHATTERING ALARMS gt LOGIN gt MAIN MENU gt ALARMS gt EDIT ALARMS gt 1 16 gt SHOW ALARM INFO gt ALARM INFO INCLUDES ALARM NUMBER ENABLED Y N ACTIVE Y N MASKED Y N ACTION WHEN ACTIVE LAST ACTIVATION gt MOVE 4 TO SAVE amp EXIT CLEAR COUNTERS gt LOGIN gt MAIN MENU gt ALARMS gt EDIT ALARMS gt 1 16 gt CLEAR COUNTERS MOVE TO SELECT YES OR NO MOVE 4 TO SAVE amp EXIT qe 13 CONTACT TECHNICAL SUPPORT Redvision Technical Support Helpline tel 14 TECHNICAL SPECIFICATION Image sensor Model Optical zoom Digital zoom Horizontal resolution Angle of view Focal Length Min illumination CAMERA Sony EXview 1 4 HAD CCD PS FCB EX490E P RVX1
44. nd light would otherwise be obscured by blooming or silhouetting LOGIN gt MAIN MENU gt CAMERA SETTINGS gt LOW LIGHT MODE SETTINGS gt ADV CONFIG gt BACKLIGHT COMPENSATION MOVE gt TO SELECT ON OFF MOVE 4 TO SAVE amp EXIT IMAGE STABILISER SONY MODULE LOGIN gt MAIN MENU gt CAMERA SETTINGS gt LOW LIGHT MODE SETTINGS gt ADV CONFIG gt IMAGE STABILISER MOVE 4 gt TO SELECT ON OFF MOVE 4 TO SAVE 8 EXIT WHITE BALANCE gt LOGIN gt MAIN MENU gt CAMERA SETTINGS gt LOW LIGHT MODE SETTINGS gt ADV CONFIG gt WHITE BALANCE MOVE 4 gt TO SELECT OUTDOOR AUTO ATW OUTDOOR INDOOR AUTO SODIUM LAMP SODIUM LAMP AUTO MOVE 4 TO SAVE 8 EXIT WIDE DYNAMIC RANGE gt LOGIN gt MAIN MENU gt CAMERA SETTINGS gt LOW LIGHT MODE SETTINGS gt ADV CONFIG gt WIDE DYNAMIC RANGE MOVE 4 gt TO SELECT OFF AUTO ON gt MOVE 4 TO SAVE 8 EXIT NOISE REDUCTION PARKED LOGIN gt MAIN MENU gt CAMERA SETTINGS gt LOW LIGHT MODE SETTINGS gt ADV CONFIG gt NOISE REDUCTION PARKED gt MOVE 4 gt 10 ADJUST 0 to 5 2 IS DEFAULT MOVE 4 TO SAVE 8 EXIT NOISE REDUCTION MOVING gt LOGIN gt MAIN MENU gt CAMERA SETTINGS gt LOW LIGHT MODE SETTINGS gt ADV CONFIG gt NOISE REDUCTION MOVING MOVE gt TO ADJUST 0 to 5 0 IS DEFAULT MOVE 4 TO SAVE 8 EXIT SPOT AE SONY MODULE gt LOGIN gt MAIN MENU gt CAMERA SETTINGS gt LOW LIGHT MODE SETTINGS gt ADV CONFIG gt SPOT AE MOVE 4
45. ompensation can be either positive additional exposure or negative reduced exposure Default setting 0 gt LOGIN gt MAIN MENU gt CAMERA SETTINGS gt LOW LIGHT MODE SETTINGS gt EXPOSURE COMPENSATION MOVE TO ADJUST EXPOSURE LEVEL BETWEEN 7 AND 7 MOVE 4 TO SAVE amp EXIT JOYSTICK FOCUS MODE There are two settings AUTO focus amp MANUAL focus Default setting for NIGHT is AUTO gt LOGIN gt MAIN MENU gt CAMERA SETTINGS gt LOW LIGHT MODE SETTINGS gt JOYSTICK FOCUS MODE MOVE TO SELECT AUTO OR MANUAL MOVE 4 TO SAVE amp EXIT PRESET FOCUS MODE SONY MODULE There are two modes AUTO amp STORED Default setting for NIGHT is STORED LOGIN gt MAIN MENU gt CAMERA SETTINGS gt LOW LIGHT MODE SETTINGS gt PRESET FOCUS MODE gt MOVE TO SELECT AUTO OR STORED MOVE 4 TO SAVE amp EXIT ADVANCED CONFIGURATION LOGIN gt MAIN MENU gt CAMERA SETTINGS gt LOW LIGHT MODE SETTINGS gt ADVANCED CONFIGURATION ZOOM LIMIT SONY MODULE This can be adjusted from 10 to 100 gt LOGIN gt MAIN MENU gt CAMERA SETTINGS gt LOW LIGHT MODE SETTINGS gt ADV CONFIG gt ZOOM LIMIT gt MOVE TO ADJUST ZOOM LIMIT BETWEEN 10 and 100 MOVE 4 TO SAVE amp EXIT 8 2 6 2 8 2 6 3 8 2 6 4 8 2 6 5 8 2 6 6 8 2 6 7 8 2 6 8 8 2 6 9 X SERIES USER MANUAL BACKLIGHT COMPENSATION The ability of a Camera to compensate in cases where a subject with a large amount of backgrou
46. rmination Switches 6 amp 7 are NOT used 4 3 1 4 4 X SERIES USER MANUAL PROTOCOL ALARM MODULE TABLE 16 Protocol Baud Rate RS 485 Termination DIP SWITCH No 4 5 6 7 8 BBV Coax NOT NOT Pelco P USED USED Pelco D Dennard Bosch ForwardVision BBV 422 TECH SUPPORT COMMENT Alarm module PROTOCOL should be set to the same PROTOCOL as the camera BAUD RATE ALARM MODULE 6 CO k 65 63 ex C OO N TABLE 17 Protocol Baud Rate RS 485 Termination 6 7 NOT NOT USED USED DIP SWITCH No 2400 4800 9600 lt O 19200 TECH SUPPORT COMMENT Alarm module BAUD RATE should be set to the same BAUD RATE as the camera PELCO D normally uses 2400 PELCO P normally uses 4800 RS485 TERMINATION ALARM MODULE See 4 5 1 for TERMINATION SCENARIOS TABLE 18 Protocol 6 RS 485 Termination DIP SWITCH No 3 6 7 OFF 0 0 0 NOT NOT 0 0 1 0 USED USED 1 ALARM INPUTS 1 16 sets of volt free Contacts which can be configured using the onboard 8 way dip S3 amp S4 FIG 8 page 8 for either normally open or normally closed operation See 4 5 below ALARM INPUT GROUNDS 16 Alarm Inputs are provided to match 16 Ground Inputs 4 4 2 4 5 4 5 1 X SERIES USER MANUAL RELAY OUTPUTS VOLT FREE There are 3 relay outputs NO NC 0V output Alarms Wash and Aux ALARMS are tied into ALARM INPUTS
47. s 24V DC amp is supplied in a weather proof ABS box rated IP67 Video Signal Video Screen White Orange NOT USED 6 RED 24Vdc 7 Centre BLACK 006 FIG 7 METAL COVER REDVISION POWER SUPPLY RVX PSU 1 Mount the Redvision PSU in a position so it cannot be interfered with intentionally or accidentally Ideally use a lockable cabinet 2 Securely fix the Redvision PSU using appropriate size screws and ensure the cable glands have sufficient clearance to allow the cables to enter 3 All cables should be channelled through the appropriate sized gland holes MAINS INPUT 4 It is recommended that a good quality screened data pair or coax is used for DOME transmitting data signal CONNECTIONS 5 If the Redvision alarm module and or wireless PIR module is to be used refer EARTH to section 4 and 5 TERMINAL 6 If Star configuration is used it is recommended a suitable Star Card interface is used 7 Only use Redvision supplied umbilical cables for connecting E 2 the X SERIES ball PTZ dome 6 Redvision PSU Warranty will be void if these cables are extended between the PTZ dome unit and PSU Extending cables could also compromise safety gt iss ARN LEDS VOLTAGE gt Input 110V 230V j Output 24Vdc 2A RVX PSU INTERNAL CONNECTIONS MAINS INPUT TABLE 6 IDENT MAINS POWER LIVE LIVE BROWN 110 230Vac Connection via 2 way terminal block NEUTRAL NEUTRAL BLUE Connection vi
48. set view of the most current alarm The alarm overide is the time the Camera will wait before over riding the operator s joystick commands and moving to alarm action The over ride time can be set to between 1 and 20 seconds Default is 10 seconds gt LOGIN gt MAIN MENU gt ALARMS gt ALARM OVERIDE TIME MOVE TO CHANGE VALUE 1 20 SECS MOVE 4 TO SAVE amp EXIT ALARM CYCLE TIME The alarm cycle time programmed in seconds is the time it takes to tour the presets of still active alarms Default is 3 seconds This function will be ignored if alarms are connected directly to third party control equipment rather than the Redvision Alarm Module RV PSU ALM 16 amp RV PSU ALM16 W LOGIN gt MAIN MENU gt ALARMS gt NEW ALARM CYCLE TIME MOVE TO CHANGE VALUE 1 20 SECS MOVE 4 TO SAVE amp EXIT 12 4 12 4 1 12 4 2 12 4 3 12 4 4 12 4 5 12 4 6 X SERIES USER MANUAL EDIT ALARMS Use this menu to program how alarms are configured e g Create a weekday time schedule when alarms are automatically enabled or disabled and the type of action required when an alarm is enabled amp subsequently activated etc Alarm dwell 12 4 7 time can also be programmed in the menu LOGIN gt MAIN MENU gt ALARMS gt EDIT ALARMS gt 1 16 gt ACTIVE TIME WEEKDAYS LOGIN gt MAIN MENU gt ALARMS gt EDIT ALARMS gt 1 16 gt ACTIVE TIME WEEKDAYS MOVE 4 TO SELECT HOUR TIME BLOCKS MOVE TO SELECT
49. tion n 2 IPAE DOWN T The transmission needs to be matched between the Dome Head 3 Y Site Code on the wireless alarm module amp the Site Code within 4 A A Y Y the PIR detector see separate PIR installation guide supplied 5 4 Y A with the PIR EIE LE One or more domes wil respond to any wireless PIR within range A A Y Y A ten A providing the Dome Head Site Code amp corresponding PIR Site 9 Y Code match 10 A Y Y 11 A Y Y 12 Y A Y Y 13 Y Y 14 Y Y Y 15 Y Y Y A 16 4 Y Y Y Y FIG 8 METAL COVER CONTROL CONNECTIONS MAINS INPUT ALARM INPUTS 50 CONNECTIONS EARTH TERMINAL ALARM OUTPUTS lt NO NC ALARMS S3 amp 54 CONFIG DIP SWITCH S5 WIRELESS 8 WAY gt DIP SWITCH AERIAL POSITIONING RV PSU ALM16 W To maximise the transmission range install the PSU externally with the aerial pointing through the gland towards the ground An optional booster aerial RV AE434 can be used to significantly improve signal and range It is recommended to use the booster aerial if the PIRs are installed on metal clad buildings IF RETRO FITTING WIRELESS ALARM RECEIVER If Retro Fitting a wireless alarm receiver card onto an existing 16 way alarm module RVX PSU ALM16 W observe the following steps A ISOLATE POWER FROM PSU YOU CANNOT H
50. tivates ALARM ACTIONS Go to preset will go to preset if set and dwell on it for dwell seconds Otherwise it will just display alarm title if set or alarm number if not on screen for dwell before moving on Go to tour will invoke the selected tour if set for dwell seconds Otherwise it will just display alarm title if set alarm number if not on screen for dwell before moving on It is down to the user to ensure that the alarm dwell time gives sufficient time to run the tour or as much of the tour as they require Message only will display alarm title if set number if not on screen for dwell seconds before moving on Silent will do nothing and move on instantly When all alarms are cleared 12 4 9 the Camera will be pointing at wherever the last preset was or running the last tour This will continue until either the user moves the Camera or the RESTORE MODE 10 4 4 if set kicks in ENABLE DISABLE ALARMS Alarms need to be enabled in order to function correctly This feature can also be used to disable nuisance alarms caused by faulty alarm input devices such as PIRs The alarm default setting is all alarms enabled block LOGIN gt MAIN MENU gt ALARMS gt ENABLE ALARMS MOVE 4 gt TO SELECT ALARM NUMBER 1 TO 6 MOVE gt gt TO ENABLE BLOCK DISABLE CLEAR MOVE 4 TO SAVE amp EXIT ALARM OVER RIDE On alarm activation the Camera automatically switches to the pre
51. tive reduced exposure Default setting 0 LOGIN gt MAIN MENU gt CAMERA SETTINGS gt DAY MODE SETTINGS gt EXPOSURE COMPENSATION MOVE gt gt TO ADJUST EXPOSURE LEVEL BETWEEN 7 AND 7 MOVE 4 TO SAVE amp EXIT JOYSTICK FOCUS MODE There are two settings AUTO focus amp MANUAL focus Default setting for day is auto LOGIN gt MAIN MENU gt CAMERA SETTINGS gt DAY MODE SETTINGS gt JOYSTICK FOCUS MODE MOVE TO SELECT AUTO OR MANUAL MOVE 4 TO SAVE amp EXIT PRESET FOCUS MODE SONY MODULE There are two modes auto amp stored Default setting for day is auto LOGIN gt MAIN MENU gt CAMERA SETTINGS gt DAY MODE SETTINGS gt PRESET FOCUS MODE gt MOVE TO SELECT AUTO OR STORED MOVE 4 TO SAVE amp EXIT ADVANCED CONFIGURATION gt LOGIN gt MAIN MENU gt CAMERA SETTINGS gt DAY MODE SETTINGS gt ADVANCED CONFIGURATION ZOOM LIMIT SONY MODULE This can be adjusted from 10 to 100 gt LOGIN gt MAIN MENU gt CAMERA SETTINGS gt DAY MODE SETTINGS gt ZOOM LIMIT MOVE a TO CHANGE ZOOM LIMIT 10 to 100 gt MOVE 4 TO SAVE amp EXIT 8 1 5 2 8 1 5 3 8 1 5 4 8 1 5 5 8 1 5 6 8 1 5 7 8 1 5 8 8 1 5 9 8 1 5 10 X SERIES USER MANUAL BACKLIGHT COMPENSATION The ability of a Camera to compensate in cases where a subject with a large amount of background light would otherwise be obscured by blooming or silhouetting Can be turned ON or OFF Default is off
52. uct and no product will be accepted for repair replacement credit or refund without the written authorisation of Redvision or in accordance with Redvision s written instructions In the case of any such return the buyer shall bear the risk of loss or damage and shall prepay all transportation charges to Redvision Repaired or replacement product will be shipped with freight prepaid by Redvision and the buyer shall bear the risk of loss or damage The replaced product shall become Redvision s property In no event shall Redvision be responsible for de installation or reinstallation of the product or for the expenses thereof If it is determined that product is not defective the buyer shall pay Redvision all costs of handling inspection repairs and transportation at Redvision s then prevailing rates Repairs and replacements covered by the above warranty are warranted to be free from defects as set forth above except that the defect must appear Within three 3 months from the date of repair or replacement or Prior to the expiration of the above twenty four 24 month period whichever is later With respect to product not manufactured by Redvision to the extent permitted extends the warranties and affords the remedies to the buyer given to Redvision by its vendor of said products The foregoing warranties do not extend To expendable items To experimental or development products To product which has been subjected to misuse negl
53. w business park High Street Bordon Hampshire GU35 0AX United Kingdom Company registration UK3952814 www redvisioncctv com X SERIES USER MANUAL Redvision
54. ws with 2 5mm allen key provided See FIG A below FIG B MOUNTING ORIENTATION OBSERVE THE FOLLOWING PRECAUTIONS WHEN INSTALLING 1 Mount the Camera in a position where it cannot be be interfered with either intentionally or accidentally 2 The mounting surface should be capable of supporting the weight of both the Camera and mounting brackets under all expected conditions of load vibration and temperature 3 The mounting brackets should be fitted in accordance with instructions and should observe all appropriate safety precautions amp local building regulations 4 Ensure the Camera is in the correct orientation see FIG B above ATTACHING CAMERA TO BRACKET BRACKET INSTALLATION Fixings to the various bracket types will depend on the fixing surface It is important to use adequate quality fixings to safely support the complete Dome Ball PTZ assembly Fixing slots on a 4 PCD provide adequate clearance for 6mm bolts if attaching the Pedestal or Swan Mount to the mast FLYING LEAD If using a Swan Pedestal Pendant Mount install the Fly Lead optionally through the Central Mounting Tube or via a 20mm Gland Entry Point The Gland Entry is supplied with a 20 x 1mm thread to accomodate industry standard 20mm Glands ee X SERIES USER MANUAL ATTACHING CAMERA TO THE BRACKET See Fig C amp D below 1 Remove Mount Cover Plate 2 Fully unscrew Hand Lock Nut 3 Offer Camera to Bracket The Mounting Boss orientation