User Manual - Riello UPS
Contents
1. This feature is used for Windows NT 2000 or XP systems and enables the configuration to send email by SMTP interface To use this support the email service must be correct configured on the computer Email configuration SMTP configuration Enable SMTP support SMTP server name address SMTP domain name Sender name sender email address Ermail subject Parameter name Parameter description Enable SMTP support Enable or disable SMTP support When disabled the UPSMON cannot send emails through SMTP support The IP address or host name of your SMTP server The SMTP server is a specific computer in SMTP server name address the local network or Internet service provider which 1s used to collect and distribute email to the users For detailed information contact the administrator of the network The domain name is used to correctly log into the SMTP server Some SMTP servers control it for authorised access For detailed information contact the administrator of the network The name of the sender which is included in the email Informational only The sender email address is also included in email header and will allow possible replies to be SMTP domain name Sender email address received on the email message for Upsmon Email subject The subject of the email IN ATTENTION For Windows 9x and ME these operating systems use the MAPI interface and sending email is dependent on the correct configuration and functionality of M
2. Date Hour Device Yinpl W impe W vimpa v YBa BatPerc 5 Eatlimelm Poutl 5 Poute 2 Pouta 5 A 10 10 2007 17 25 42 UPS 04 232 10 10 2007 17 25 47 UFS 04 ER 10 10 2007 17 25 52 UPS 04 232 10 10 2007 17 25 57 UFS 04 eae 10 10 2007 17 26 02 UPS 04 232 10 10 2007 17 26 07 UFS 04 fae 10 10 2007 17 26 12 UPS 04 232 10 10 2007 172617 UPS 04 ER 10 10 2007 17 26 22 UPS 04 232 10 10 2007 17 26 27 UFS 04 ER 10 10 2007 17 26 32 UPS 04 eae 10 10 2007 17 26 37 UPS 04 eae 10 10 2007 17 26 42 UPS 04 10 10 2007 17 26 47 UPS 04 10 10 2007 17 26 52 UPS 04 10 10 2007 17 26 57 UPS 04 10 10 2007 1270 UPS 04 1010 2007 17 27 07 UPS 04 232 A S el D a aAa A A A O AA AAO AGAO A O Daa aAa aAa aAa Aa AAA AAAA A GA A D2 2 a a G A G e GAG A GA O O re O me 2an anaa aana aAa Aa AA AA A A AA Coen aa aAa aAa Aa AAA A A A Jr e JO e Or e Or aAa Aa AA A A A AA l Graphic module 1 ro 4 ee RR RE ee ee EREEREER EE ser bre ey Nice oe gl es aa EM UPS 02 Uinp1 EM UPS 02 Uinp2 EM UPS 02 Uinp3 01 10 2007 01 10 2007 14 00 00 15 00 00 oom control Scroll control Dialog control ATTENTION for some Ups type is available also an internal log downloaded by the Ups through Upsview ATTENTION this menu is available only for Ups monitored by local Upsagent 62 e Uninstallation of the UPSMON UPSMON User Manual 1 2 6 Popupmenu Standard Detail Block Scheme Properties 48 Bar colour Insert IP Addr
3. UPSMON User Manual OMNU106NPB GB This release supersedes all previous releases Specifications are subject to change without any prior notice UPSMON User Manual Contents e i Limited Warranty This software and the enclosed materials are provided without warranty of any kind The entire risk of the software quality performance of the program media free of defects faulty workmanship incorrect use of the software or UPS error free documentation and enclosed material is assumed by the user We do not take any responsibility for the correct function of the software and the security of your system or files which might be damaged due to possible non correct function of our software There is no warranty to the correct functions of the software with the operating systems loss of data or interruption of work processes other UPS problems or to other errors that may occur from this combination Copyright The information contained in this manual is non conditional and may be changed without any notice The software manufacturer undertakes no obligations with this information The software described in this manual is given on the basis of a license contract and an obligation to secrecy i e an obligation not to further publicise the software material The purchaser may make a single copy of the software material for backup purposes No parts of this manual may be transferred to third persons either electronically mechanically by photocopies or
4. 5 9 A Line 1 6 E Bypass values Frequency Hr Line 1 6 Y System temp C 34 68 e Uninstallation of the UPSMON UPSMON User Manual 2 2 4 View Active Status The UPS status table shows the status of the UPS and 1f a situation with the UPS or the system 1s critical lerminal upsview BOx 24 UPSMOM Monitoring Version 5 8 B81 ups 81 Serial Communication is OK Gutout Powered Battery Charged Battery Charging gt 1 Mew Active stotus 2 View Active alarms Vies a ion 4 View General state a uit 2 2 5 View Active Alarms Some UPS types have a special table facility showing the alarms status lerminal upsview 0x24 UPSHOM Monitoring Version 5 8 Bel ups 81 Serial Communication is OK This function is mot possible for actual UPS type 1 View Active stotus gt 2 View Active alarms Vies Device information 4 View General state a uit UPSMON User Manual Uninstallation of the UPSMON e 69 2 2 6 View device information Show the nominal data of the Ups i i o D i i mi erminal Upsviewm oO x 24 UPSAON Honitoring Version 5 6 BB us 81 Serial Communication is OK Identification code LPS model US SOftwore version SABIA Input Output Configuration Horophose Porophose Nominal Nominal Nominal Nominal Nominal Nominal 1 View Actire View Active gt 3 Meu Device Power VA 460 power W
5. Version 5 0 7 Main Network services UPS connections Remote sensor Configurations Schedule States and actions About Email Address list Name Email address Modem m GSM Modem Messages 9 2 GSM number list E Name Telephone number Voice modem Ro Adding or editing email contact details or GSM number details select the Add or Edit button from the email list or from the GSM number list GSM number Parameters Parameters Mame Mame Email address Telephone number It is possible to specify the name and email address or GSM number for the recipients This will only operate if the Email messages checkbox or SMS checkbox in jobs parameters tab has been selected In the event of an alarm condition occurring a messages about the UPS status will be sent to the specified users this message will also be sent by the standard Windows MAPI interface on Windows 9x ME versions On Windows NT 2000 and XP a direct SMTP interface is used if it is enabled Before using this option the email service on the computer must be configured The maximum number of email recipients is 10 The Test emails and the Test SMS button can be used to send test email or test SMS messages by the Upsagent to confirm correct operation The Upsetup will try to send the test email message through MAPI or through SMTP if it is enabled UPSMON User Manual Advanced UPSMON Configuration e 27 1 5 1 Email support configuration
6. 1 UPS configuration select the Add or Modify button UPS configuration UPS identification UPS Mame UPS 04 g PRTE code GPSERTIZ0RU UPS Seral Number Connection P Local Remote IF ddress 255 255 255 259 Device System shutdown Password protection Remote sensor El Delay after start AC Fail min DF autonomy time is below than min UPS shutdown SD Enable Parameter name Parameter description UPS Name UPS identification name PRTK Code The PRTK is used to determine the type of UPS to be monitored the code to be entered can be located on the UPS UPS Serial number UPS connection Password protection Remote sensors 20 e Advanced UPSMON Configuration The UPS have unique serial numbers this number used to identify the UPS Enter the serial number as printed on the UPS identification label This field is important for the correct operation with Teleservice program The UPS connection must be set to the chosen method to be used for the communication between the computer and UPS s The first method of connection is local this connection method is used when the connection to the UPS is to be made via a serial port if this method is to be used ensure that the correct serial port and UPS address is selected All the other settings for the serial connection baud speed etc are automatically set for the selected UPS type The second method of connection is remote via a network for this
7. 245 Battery Copocity Ah 7 Battery Voltage Vj 12 Output Voltoge 4 238 Output Frequency Hz 58 6 SAT a Lora information 4 View General state B Quit 2 2 7 Event log The Event list displays the current Upsagent activities This is the list of events and information about the UPS and its agent during the Upsagent monitoring activity All events contain the date time and the name of the event To use event log you must configure it in the Upsetup module 21 607 266 16 43 15 21 67 266 16 44 35 4 67 266 16244255 41 67 26 16 44 79 lerminal UpSVieWw BOx24 Poge 1 1 4 Start Upsagent version 5 8 Ba Received termination Signal Stop UinsAgent Start UpsAgent Version 5 6 Bai gt 1 Previous events Next everis 3 Beginning file Ending file B Quit 70 e Uninstallation of the UPSMON UPSMON User Manual 2 2 8 Data log The data log list displays logged measured parameters from the UPS such as the input voltage battery voltage capacity runtime and output load All of the information contains the date time device name and measured values To use data log you must configure it in the Upsetup module The data logged can be used by other programs for example 1f you need to generate a graphic view The data is logged into a standard text file which may be simply imported into other programs 2 2 9 Functions It is possible to execute commands
8. Advanced UPSMON Configuration e 51 If selected this enables a message to be sent to remote users via the network For Windows the message is broadcast to all connected users or only to some users depend on the configuration inserted in the page Configurations for other systems the ups mess scr or ncf for Novell Broadcast message Netware script is executed Recommendation Use the wall command to send message to all connected users on Unix systems If selected this option enables the shutdown of the system for Windows the ups shut cmd file is searched for possible user specified commands before shutdown e g quit databases then the standard system shutdown 1s executed using the WIN32 API functions For other systems the ups shut scr or cmd or ncf script 1s started with the appropriate commands to provide the correct shutdown of the computer ATTENTION System shutdown conditions defined in the UPS connection menu is Shutdown system not dependent on this job ATTENTION You cannot specify a Shutdown system action for AC Fail or Battery low these are dependent on the UPS connection configuration The system AN shutdown time after AC Fail may be defined by two independent values fixed time from AC Fail and or specific remaining backup time The Battery Low event causes an immediate system shutdown Direct email support is for Windows only when using other system a script etc must be used to suit the individual system N
9. States and actions About Software version UPSMON Configuration Version 5 0 7 5 0 7 Copyright 2008 All Rights Rese Full Version Unlock full version R The About tab contains the information with regards to the UPSMON including the version and copyright In addition to this is the Enter code button this button is used to enter the CDROM serial and license number to convert the STANDARD version to the FULL version of UPSMON The STANDARD version is used for MS Windows Novell Netware Linux and Mac OS X version when one UPS is to be monitored The FULL version will allow one UPS to be monitored locally and up to 31 UPS to be monitored via a network by the Upsagent To change the STANDARD version to the FULL version you must enter the CDROM serial number and relevant License number Version Standard gt Full RAB 5454 All SWO8S 004 This is the back side of your CD ROM The serial number is in the top right corner In this example the senal number is RAB 5454 Code insertion SW Seral number Sw Licence number UPSMON User Manual Advanced UPSMON Configuration e 37 Zz Upsetup for UNIX To configure the parameters for UPSMON on UNIX use the text version of Upsetup The style and parameters to be set is of course dependent on the text interface used A common problem is finding the correct serial device name for the UNIX system The following table gives the usual device names for different UNIX systems U
10. back up time fourth lowest time is considered on so on 44 e Advanced UPSMON Configuration UPSMON User Manual Enable system shutdown if all of the UPS are supplied from the batteries le th h f e ROD tie VpS ceo ala er It is possible to shutdown the groups UPS together with the system after the specified delay system shutdown It is possible to save the UPS parallel event configuration and also possible to load it on another computer without re inserting the same configuration this can be done using the Load jobs and Save jobs System shutdown parameters for the parallel group can be defined The shutdown may depend on the fact that all the UPS within the parallel group are operating in battery mode To configure the selected actions for the group events there are the next menu erminal upsetup 80x24 Jokes configuration for parallel group 1 Associated erent List Log erent Execute file Local BESSOGE Broadcast NESSE Syetes shutdown Email o 585 io Coll to Teleguard 16 Message Event 2 5 4 5 6 T g q 11 Cael Action name Action description In the message text it is possible to add actual values or information which will be displayed along with the original information these are as follows NAME The UPS or Group name will be added to the message See main parameters dialog box SYSNAME The System name will be added to the
11. button The event shall be removed from the list It is possible to modify the priority of a simple event by selecting it on the Associated event list list and double click on it For each composite event related to the parallel group it is possible to set the actions that Upsagent will perform when the composite event will occur It is possible to define the message that will be sent at the composite event creation This message will be shown on the Message column of the Activated jobs for parallel group list Action name Action description In the message text it is possible to add actual values or information which will be displayed along with the original information these are as follows NAME The UPS or Group name will be added to the message See main parameters dialog box SYSNAME The System name will be added to the message See main parameters dialog box Message SYSLOC The System location will be added to the message See main parameters dialog box SHUTTIME The time before shutdown of the local system in seconds SHUTTIMEI The time before shutdown of the local system in the format hh mm ss STH STM e STS The three values the time before the shutdown of the local system in hours minutes and seconds REMTIME The remaining UPS battery autonomy REMCAP The remaining UPS battery capacity If selected the event will to be logged into event log file system Application event log On UNIX platfor
12. chmod 777 setup scr Use a case sensitive mount command for your CD ROM if an execution error occurs 8 e Installation of the UPSMON UPSMON User Manual 2 To install UPSMON run the specific command for the operating system where the software is to be installed Operating System Command cd directory pkg_add upsmon BSD swinstall s directory upsmon swmgr f directory dpkg i directory upsmon xxx deb rpm i directory upsmon xxx rpm pkgadd d directory upsmon SA The install command will expand automatically all the files and will create the startup shortcut for Upsagent in the correct directory for the specific UNIX operating system 4 After successfully installing the software launch the Upsetup program When prompted enter the correct PRTK code for the UPS to be monitored this code is located on a label which can be found on either the front or the rear of the UPS and failure to input this code will prevent the operation of UPSMON 5 When installing UPSMON on UNIX the software requires the CDROM serial and license number The serial and license number can be obtained from the UPS manufacturer or supplier 6 The configuration of UPSMON is performed using the Upsetup program this will enable correct communication with the UPS and setup of the software operational parameters ATTENTION To copy the UPSMON into the Unix system from the CD medium a CD ROM drive and a CDFS filesystem driver ISO 9660 is required Othe
13. in the Netman 6 For further information refer to this User Manual 6 e Quick start guide UPSMON User Manual lll Installation of UPSMON L Before the installation Before commencing the software installation please read this manual carefully 1 1 Hardware requirements UPS Connect the UPS to the chosen serial port of your computer various UPS provide several methods of communication interfacing please ensure that the interface for RS 232 communication is used Cable To ensure correct operation of this software ensure that the correct communications cable is used the correct cable should be supplied either with this software or the UPS Do not connect any other cable between UPS and computer 1 2 Software requirements TCP IP UPSMON is based on TCP IP therefore for this function to operate TCP IP must be installed If TCP IP is not installed communication with the UPS is only possible via a local serial connection and thus the Upsview can only connect to the Upsagent via shared memory on the local computer A dedicated system port for the UPS To ensure the correct communication with a local UPS via a serial port please ensure that the selected port is free not required by any other device or program This is very important for UNIX environments when the system is often running some demon how getty for connection terminal through the serial port No other process must be operational using the selected serial port used
14. message See main parameters dialog box Message SYSLOC The System location will be added to the message See main parameters dialog box SHUTTIME The time before shutdown of the local system in seconds SHUTTIMEI The time before shutdown of the local system in the format hh mm ss STH STM e STS The three values the time before the shutdown of the local system in hours minutes and seconds REMTIME The remaining UPS battery autonomy REMCAP The remaining UPS battery capacity If selected the event will to be logged into event log file Log event ATTENTION On Windows NT 2000 or XP platforms the events are also logged in the system Application event log On UNIX platforms the events are also logged into the system log this depends on system configuration see syslog manual Execute tile If selected the Upsagent will execute a specified command file when a selected condition occurs Recommendation Always use the full path name for the file UPSMONUserManual Advanced UPSMON Configuration e 45 lt 2 2 i User Manual Advanced UPSMON Configuration e 45 If selected this enables message to be displayed on the local computer the messages can be delayed to stop short event changes being displayed unnecessarily e g short power problems or Local message repeated to ensure acknowledgment For Windows the message is displayed on the desktop OS 2 executes the ups loc cmd script Novell Netware sends the message to t
15. on the local UPS A list of these commands is dependent on the UPS type but the UPS shutdown and reboot command is supported by all UPS types For some UPS types it is possible to start UPS internal tests or a UPS battery test lerminal Upsviom 80x 24 gt 1 UPS shutdow Trehoot 2 Botter test 3 Corcel test or commas 4 FS on bypass 5 FS on inverter 6 Change password A Quit UPSMON User Manual Uninstallation of the UPSMON e 71 3 The Upsview for Novell Netware On Novell Netware systems it is possible to monitor the UPS using one of two methods The first method is to use the Upsview for Windows This has the same interface as described in the Upsview for Windows section The second method is to use the Upsview nlm module directly on the server console This is able to monitor the UPS without a connected workstation however this program is limited by the alpha numeric interface black white for Novell 3 12 and coloured for higher versions The styles of the displayed screens are dependent on the type of alpha numeric interface used AG Remote Console nee e eS a onfiguration unctions UPS 01 Serial On Line Ups On Input Voltage 220 U Line Present Load 2 45 2 Battery Capacity 2 100 amp Battery Voltage 2 27 2 U Output frequency 50 0 Hz Output voltage 2 234 U futonomy Time 15 min 72 e Uninstallation of the UPSMON UPSMON User Manual 4 The Upsview for
16. pipe O for user eparsi 22 10 2007 11 39 01 Connecting client to pipe 22 10 2007 11 39 01 Start Ups gent version 5 0 5 de 10 2007 11 39 01 Communication Pipe Connected 22 10 2007 11 39 11 InstanceThread arrived hE vent at de 10 2007 11 59 11 Stop Upsigent 22 10 2007 ease Create Named pipe O 2e 10 2007 11 39 22 Connecting clent to pipe 22 10 2007 17 39 22 Start Ups gent Version 5 0 5 22 10 2007 11 39 22 Communication Pipe Connected 22 10 2007 11 39 44 InstanceThread arrived RE ventat gt emt 22 10 2007 11 39 44 Stop UpsAgent 22 10 2007 11 40 50 Create Named pipe O for user eparsi 22 10 2007 11 40 50 Connecting client to pipe 22 10 2007 11 40 50 Start Ups gent Version 5 0 5 2210 2007 114050 o Communication Pipe Connected m e JIJ EJ The data log list displays logged measured parameters from the UPS such as the input voltage battery voltage capacity runtime and output load All of the information contains the date time device name and measured values To use data log you must configure it in the Upsetup module The data logged can be used by other programs for example 1f you need to generate a graphic view The data is logged into a standard text file which may be simply imported into other programs The data log also contains a Graph engine module this module shows the measured values in a graph format UPSMON User Manual Uninstallation of the UPSMON e 61 Data log file Selected UPS 01 UFS 01
17. similar means without the express written permission of the software manufacturer The UPSVIEW software includes the license for using the UPS service at one server with one UPS For operation at several servers a license for every new server is required It doesn t matter if the UPS service runs at that location or if the server is halted by an UPS service via remote command The service programs are generally delivered as a single license If there is more than one disk in one package all of them have the same serial number and must not be used for future installations To use a single CD ROM for several multi server shutdown installations you have to purchase additional CD license keys Copyright of the European Union is effective Copyright EU Copyright 2007 RPS S p a All rights reserved ii e Contents UPSMON User Manual Contents I What is UPSMON II Quick Start Guide 1 Quick start guide to installing the software III Installation of UPSMON 1 Before the installation 1 1 Hardware requirements 12 Software requirements 1 3 User requirements 2 Installation 2 1 Windows 22 UNIX ZS Novell Netware 2 4 Mac OS X IV Simple UPSMON Configuration Wizard 1 Wizsetup for Windows 2 Wizsetup for JAVA and MAC OS X V Advanced UPSMON Configuration 1 Upsetup for Windows 1 1 Main parameters 1 2 Network services 1 3 UPS connections 1 4 Remote sensors 1 5 Configurations 1 6 Action scheduler 1 7 States and action
18. stands for the board and 1 for the port address A newly created device should be moved from the directory dev term to dev UPSMON User Manual UPSMON User Manual Please print out the help documents with man termadd All options are stored for this command With termdel this port is deleted With termshow grep UPS the configuration can be displayed Using SCO computer systems a terminal translator mapchan or mapkey may be mapped on the configured tty port with etc default mapchan in most cases only on coml ttya This causes a malfunction of the RS 232 port Check if this process is active and delete it if necessary Check in the file etc gettydefs which baud rate has been assigned to the port and change it to correspond to the UPS parameter HP UNIX computers sometimes have the following entry in the inittab ups0 respawn rtprio O usr ups_mond f etc ups_conf In the SAM menu Peripheral Devices gt Uninterruptible Power Supplies this entry is to be found but not activated But this causes the device not to work correctly with UPSMON Delete this entry and restart Troubleshooting e 83
19. system name location personnel contact name and parameters for log files Network services The network services section is used to configure the network services such as tcpip snmp etc UPS connections The UPS connections section is used to configure a list of the UPS to be monitored by the Upsagent and the communication parameters for each UPS Remote sensors this section lets you set up to 32 sensors temperature humidity and digital I O sensors associating them with the UPS systems monitored remotely via an on line connection Configurations The configurations section is used to specify the method used to send a message to personnel who will be required to be notified with regards to an alarm condition occurring with the UPS several message types are possible such as email text voice and fax Before using any of these options you must configure the desired service on the computer Schedule parameters The schedule parameters section is used to configure any scheduled actions It is possible to specify scheduled actions such as UPS shutdown reboot test etc these actions will be executed at a specified time Jobs parameters The jobs parameters section is used to configure the jobs to be carried out by the UPSMON when an alarm condition occurs for example it is possible to customise each alarm to carry out a specific set of tasks such as run a shutdown user defined script send email SMS or network messages etc About The a
20. 2003 The basic configuration of UPSMON performed using the Wizsetup program is due in three step Is possible to open the configuration complete program Upsetup by clicking the button with the caption Upsetup 1 Welcome page in this page is possible to select the language of UPSMON Upsmon Wizard Setup Version 5 0 5 Welcome to the Wizard version of the Upsmon Setup This Wizard configures the main parameters for the Upenari Features configuration of the Ups and its connection configuration of the system and Ups shutdown Language Select language English me Version 5 0 5 Copyright 2007 All Rights Reserved UPSMON User Manual Simple UPSMON Configuration Wizard e 11 2 UPS Configuration page in this page is possible to configure UPS parameters and the connection parameters to use to communicate with UPS Upsmon Wizard Setup Version 5 0 5 Ups Configuration Ups Data Ups Mame E PATE Code Do Ups Connection Local Serial Port O Remote IP Address 3 Shutdown page in this page is possible to configure the system shutdown and the UPS shutdown Upsmon Wizard Setup Version 5 0 5 Shutdown Configuration Sistem Shubdowr 2 Delay after AC Fail min DF the autonomy is below than min Do Ups Shutdown VD Dna Delay sec HH 12 e Simple UPSMON Configuration Wizard UPSMON User Manual Zi Wizsetup for JAVA and MAC OS X enter the correct PRTK code fo
21. API based email program e g MS Outlook In NT 2000 and XP platform the MAPI interface may caused problems due to Windows system security reason 28 e Advanced UPSMON Configuration UPSMON User Manual 1 5 2 GSM support configuration This window is used to configure the GSM modem connection The GSM modem may be used to send SMS to normal GSM phones 65M Modem configuration GSM configuration g Enable GSM modem support Connection senal port LOM SMS Centre number Parameter name Parameter description 1 5 3 Network Messages support configuration This window is used to configure network messages It is possible to send the message in broadcast to all computer present in the network or select some user that will be shown in the recipients list In this case it is possible to execute a send test Messages configuration Message recipients gt To all computers broadcast To specified recipients Recipients list o Add E gt Delete UPSMON User Manual Advanced UPSMON Configuration e 29 1 5 4 Modem support configuration This window 1s used to configure the modem connection The modem may be used for communication with teleservice Modem configuration Modem configuration NR Enable modem support Connection eral port COME Primary telephone number Secondary telephone number Number of repeat calls Delay between calls min Accept incomming calls Parameter name Parameter description Ena
22. JAVA and Mac OS X The Upsview user interface is nearly identical to the Windows version All parameters are the same as described in the Windows Upsview section refer to the Windows section UPSMON Monitoring Version 5 0 2 Sy Local General state E ups 01 1 e E Remote uso Battery Voltage J 545 40 F 60 r Other values APP 7 Frequency Hz Voltage LineL V Voltage Line2 v Voltage Line3 V Output 50 0 230 Bypass Line 50 0 226 Q Output Powered Battery Charged Ef Rattery Charoina pi ups 01 Communication is OK Java 1 5 0 06 64 UPSMON User Manual Uninstallation of the UPSMON e 73 Vil Uninstallation of the UPSMON ATTENTION Before attempting to carryout the uninstall procedure ensure that the Upsview or Upsetup program are not running L Uninstall procedure for Windows To uninstall from Windows it is possible to use the standard uninstall procedure for Windows designed applications For example via the Control Panel Add and remove programs or it is possible to use the uninstall icon in the UPSMON program group Ze Uninstall procedure for UNIX To uninstall from UNIX the specific uninstall program for the specific UNIX operating system must be used For further information please refer to the operating system manual 3 Uninstall procedure for Novell Netware To uninstall from Novell Netware ensure that you are connected to the server using the Window
23. NIX System Device name ATTENTION When the Upsetup program is started for first time the correct PRTK code for the UPS to be monitored must be input this code is located on a label which can be found on either the front or the rear of the UPS The Upsetup program has 5 main sections 1 General parameters this section is used to set up all of the common parameters such as the system name location personnel contact name parameters for log files and for network communication PA UPS configuration this section is used to configure a list of the UPS to be monitored by the Upsagent and the communication parameters for each UPS 3 Message configuration this section is used configure the GSM phone list to send SMS and also to configure the modem for a teleservice connection 4 Schedule this section is used to configure any scheduled actions It is possible to specify scheduled actions such as UPS shutdown reboot test etc these actions will be executed at a specified time 5 Jobs configuration this section is used to configure the jobs to be carried out by the UPSMON when an alarm condition occurs for example it is possible to customize each alarm to carry out a specific set of tasks such as run a shutdown user defined script send email SMS or network messages etc 38 e Advanced UPSMON Configuration UPSMON User Manual lerminal upsatup B0x 2 4 UPSAON Configuration UPSetup v 5 8 B81 02 2006 Copyright 2886 UPSPMON Config
24. PS Mage ups BH Type PERAL Connection Serial Coma type PHR State 2588 Communication is OF Line Present Battery 0K Load 0X z 1 View Basic 2 View Storndard 3 Meu Detail 4 View State am alarms A Quit UPSMON User Manual Uninstallation of the UPSMON e 67 2 2 2 View Standard The standard screen displays the most important operating data of the UPS system For further information with regards to this data please refer to the UPS system manual Terminal UpSsVieWw 60x24 UPSHOM Monitoring Version 5 6 Bai ups 81 Serial Communication is DK LPS On Input ol Gage Line Present Line 1 22 Y En Batter Load NM Eqttery Low Line 1 6 Evpass Or Output voltage Cver liad Line 1 23 Y Cvertemp Battery Yoltege 54 5 Y Eqtt Fai Battery Capacity 166 Alarm Output frequency 56 8 Hz Autonoey hh mm 5 31 i View Basic gt Vies Standard 3 View Detail View States and alarms A Quit 2 2 3 View Detail The Detail screen shows all of the detailed information with regards to the measured values from UPS erminal upsview 80x24 UESHON Honitoring Version 5 6 081 ups Bl Serial Communication is OK Irput Frequency Hr 58 6 Hz Line 1 24 65 Y 0 A Battery values Autonoey hh mm 5 31 Current A 6 4 A er eh i Y Copocity X 100 amp Dutput values Frequency Hz 58 8 He Line 1 23H VY
25. TANDARD version of UPSMON will only allow one UPS to be monitored either locally or via a network by the Upsagent The FULL version will allow one UPS to be monitored locally and up to 31 UPS to be monitored via a network by the Upsagent To change the STANDARD version to the FULL version you must enter the CDROM serial number and relevant License number using the About tab and the enter code dialog box The License number is available from the UPS manufacturer or supplier The FULL version of UPSMON also enables the operation of Parallel functionality This function enables the setup of groups of UPS which are working in redundant operation It is possible to create up to 10 groups with each group containing up to 8 UPS 2 UPS minimum with up to 64 event actions Parameter name Parameter description Default Defines the time interval in seconds in which the Upsagent polls for data from the UPS if the Upsagent is connected to remote UPS via network This parameter is enabled only if there is at least one Ups connected via TCP IP in the list of connected Ups The system speed Update frequency may be reduced due to permanent communication with the UPS if 3 seconds this value is too small If the value is too high the system will react slower in the case of an alarm from the UPS The recommended values are from 1 second for smaller networks or 5 10 seconds on larger networks UPSMON User Manual Advanced UPSMON Configuration e 19 1 3
26. UPS shutdown reboot E Battery test Cancel test or command Change password 60 e Uninstallation of the UPSMON UPSMON User Manual Used to send some command to the monitored Ups such as the shutdown and reboot of the Ups the execution of test battery force Ups on bypass and force Ups on inverter It is available also Cancel test or command voice that permit to cancel the last sent command this permit to return to normal condition after the force Ups on bypass command It is possible protect this command with one password that could be inserted with Change password voice Note if there aren t password press enter with password field blank at the password request AN ATTENTION the list of available commands depend of the Ups type but the Shutdown Reboot command is always supported 1 2 5 Logs Menu Eventlog a Data log Used to view the log files The Event list displays the current Upsagent activities This is the list of events and information about the UPS and its agent during the Upsagent monitoring activity All events contain the date time device name and the name of the event The event is logged into a standard text file which may be simply imported into other programs To use the event log you must configure it in the Upsetup module Event log Tile Date Hour Evert 22 10 2007 11 38 57 InstanceThread arrived hE ventat emt 22 10 2007 11 38 57 Stop Ups4gent 22 10 2007 11 39 01 Create Named
27. age E Load Jobs Hj Save Jobs Voice call 22 e Advanced UPSMON Configuration UPSMON User Manual The selected parallel group 1s shown on the Parallel group tree The user can add modify or remove the composite events related to the selected parallel group The composite events defined on the parallel group are shown on the Activated jobs for parallel group list Every composite event related to the group is made up of one or more simple events that may occur on the groups UPS These simple events are visible on the Associated event list list The composite event occurs and the defined actions are performed only when all the simple events on the list are verified on the same time A composite event is made up to 6 simple event Itis possible to add a simple event to the list of the composite events first select a new simple event from the Event list list then press the green left arrow button A dialog window will be shown on this window it is possible to set the event priority 1 e the number of the groups UPS on which the simple event must occur for making it acknowledgeable Event priority Priority Event generated for n UPS Event generated for at least n UPS Event generated for all UPS except one Event generated for all UPS It is possible to remove a simple event from the Associated event list list first select the simple event from the list then press the green right arrow
28. age in this page is possible to configure the system shutdown and the UPS shutdown 0960 Upsmon Wizard Setup 5 0 2 Shutdown Configuration System Shutdown 2 wi Delay after AC Fail min 5 Ww lf the autonomy is below than min sa 1 Enable Delay min i rm Upsetup 4a Ba kl E Next Caner Upsetup Ex amp i 14 e Simple UPSMON Configuration Wizard UPSMON User Manual V Advanced UPSMON Configuration The configuration of UPSMON is performed using the Upsetup program this will enable correct communication with the UPS and setup of the software operational parameters s 1 As A ATTENTION Bad parameters or undesirable manual changes of the upsmon ini file may cause incorrect operation of the UPSMON software primarily the Upsagent module Upsetup for Windows ATTENTION If the Upsetup program is started for first time the software will require a PRTK code therefore when prompted enter the correct PRTK code for the UPS to be monitored this code is located on a label which can be found on either the front or the rear of the UPS and failure to input this code will prevent the operation of UPSMON ATTENTION Administrative rights are required when saving the configuration using Windows NT 2000 Xp 2008 The Upsetup program 1s divided into 8 main sections L Main parameters The main parameters section is used to set up all of the common parameters such as the
29. al T O Name of the UPS connected to the SNMP adapter with which the sensors have been associated Name of UPS Note this combo box shows only the UPS for which the item Remote Sensors has been selected in the UPS configuration see paragraph Errore L origine riferimento non stata Index of the sensors from 1 to 6 connected to the SNMP adapter Maximum and minimum temperature and humidity threshold settings on the sensor When these Temperature and humidity values are exceeded the actions specified for the respective alarm in the section Status and thresholds actions see paragraph 1 7 will be carried out Note humidity thresholds are active only for humidity type sensors Determines whether the digital I O sensor has the input contact normally open the alarm is Digital input parameter triggered when the contact is closed or normally closed the alarm is triggered when the contact is opened This section is active only for digital I O type sensors Determines whether the digital I O sensor must close the output contact when a general alarm occurs on any of the sensors associated with the same SNMP adapter switching for sensor Digital output parameter na alarm and or when an alarm occurs on the UPS connected to the same adapter switching for UPS alarm This section is active only for digital I O type sensors 26 e Advanced UPSMON Configuration UPSMON User Manual 1 5 Configurations fe UPSMON Configuration
30. anced UPSMON Configuration UPSMON User Manual 1 4 Remote sensors fe UPSMON Configuration Version 5 0 7 Network services UPS connections Remote sensor Configurations Schedule States and actions About Hame sensor type Ups connection Sensor index ga Sensor 01 Marco Digital 1 0 UPS 02 gt Sensor 02 Marco Temperature UPS 02 g Sensor 03 Marco Humidity UPS 02 This window shows the list of remote sensors associated with the SNMP adapter connected to the UPS Up to 6 different types of remote sensor can be associated with an SNMP adapter using the serial port see sensor cable wiring specifications The remote sensors are divided into three categories a Temperature sensors that measure the environmental temperature around the sensor Alarms can be set to indicate when high or low temperature thresholds are exceeded so that certain actions can be taken sending an SMS or an e mail or system shutdown Temperature and humidity sensors that measure the environmental temperature and humidity around the sensor Alarms can be set to indicate when high or low temperature thresholds are exceeded so that certain actions can be taken sending an SMS or e mail or system shutdown Temperature and digital I O sensors that measure the environmental temperature around the sensor and have two contacts an Input and an Output Alarms can be set to indicate when high or low temperature thresholds are exceeded so that certa
31. battery autonomy REMCAP The remaining UPS battery capacity Default Used to reset the event action parameters to the default state For the actions associated to a particular event it is possible to specify a delay in the execution in order to filter events that last for a brief time and a interval for the repeat of the actions if the associated event is still active Both value are expressed in seconds 52 e Advanced UPSMON Configuration UPSMON User Manual 3 Upsetup for Novell Netware To configure the Novell Netware version of UPSMON it is possible use the alpha numeric interface program Upsetup nlm directly on the server Novell or the graphical Upsetup program for Microsoft Windows Remote Console Novell Netware 3 12 only uses a black white interface due to system limitations but for Novell Netware 4 x and 5 x the interface of the NLM module is in colour UPSMON User Manual Advanced UPSMON Configuration e 53 d Upsetup for JAVA and Mac OS X The Upsetup user interface is nearly identical to the Windows version All parameters are the same as described in the Windows Upsetup section refer to the Windows section In the Java version misses some particular configuration such as email fax and voice modem 800 UPSMON Configuration Main Network services UPS connections Configurations Schedule States and actions About General parameters System name Server System location Server room System contact Ad
32. ble or disable modem support When disabled the UPSMON cannot call teleservice control service Connection serial port The serial port where the modem is connected Primary Secondary telephone The telephone numbers of the teleservice control centre these are the number where the modem number will call in case of an emergency Number of repeat calls The number of times the system will attempt to call in the event of a busy line or no answer Delay between calls The minutes of delay between each call attempt Accepts incoming calls from a teleservice control centre This can be turned off for security Enable modem support Accept incoming calls reasons 30 e Advanced UPSMON Configuration UPSMON User Manual 1 5 5 Fax support configuration This window is used to configure fax support To use this support the fax service must be correct configured on the computer FAX configuration Fax Service Enable FAS support Sender name Sender company Fax number FAS printer service Local Remote Parameter name Parameter description Printer type associated to the fax service For the remote printer the user must select the location Fax printer service of the printer UPSMON User Manual Advanced UPSMON Configuration e 31 1 5 6 Voice modem support configuration This window 1s used to configure voice modem support The windows shows only 1f there 1s a voice modem recognized by the system With the button Vo
33. bout section show the software version and permit to pass to the FULL version of the program in which it could be possible to monitoring up to 32 UPS UPSMON User Manual Advanced UPSMON Configuration e 15 1 1 Main parameters ir UPSMON Configuration Version 3 0 7 General parameters System name System location system contact Language Logfile registration Event logfile enabled Data logfile enabled Local message window cose Autodose 16 e Advanced UPSMON Configuration UPSMON User Manual Parameter name Parameter description Default Defines the name of the local system Server System location Defines the location of the local system Server room System contact Defines the contact persons name for the local system Administrator Language selection All messages and text in UPSMON except some EEE ene leh Language system messages is described in lang_xx ini files The default is language lang 00 1m1 used for the standard English language interface Event logfile enabled Enables or disables the use of the event logfile for logging the events Enabled by the Upsagent module Data logfile enabled Enables or disables the use of the data logfile for logging measured Disabled values by the Upsagent module Defines the interval in seconds in which the Upsagent writes the Log rate 5 seconds measured values into the data log file Defines the minimum time in hours of t
34. by UPSMON To uninstall any processes e g getty demon please refer to the operating system user manual 1 3 User requirements To ensure correct installation of this software many systems require the user to have super user rights therefore when installing this software ensure that you are logged on as an administrator super user or root prior to the installation procedure UPSMON User Manual Installation of the UPSMON e 7 2 Installation 2 1 Windows 1 To install UPSMON use the installation CD and run the program Upsmon lt Version gt windows intel msi For Windows NT 2000 Xp and 2003 server you need administrator rights 2 When prompted select the destination folder for the program files 3 The Installation program will automatically copy all of the necessary files create a program group and install the startup shortcut for the Upsagent 4 After successfully installing the software the Upsetup or Wizsetup the wizard of UPSMON program will start automatically when prompted enter the correct PRTK code for the UPS to be monitored this code is located on a label which can be found on either the front or the rear of the UPS and failure to input this code will prevent the operation of UPSMON 5 The configuration of UPSMON is performed using the Upsetup program this will enable correct communication with the UPS and complete setup of the software operational parameters Otherwise it is possible to use the wizard Wizse
35. check that they are operational and view the measurements being recorded The types of sensors available are e Temperature measures the environmental temperature in C e Humidity and temperature measures the relative humidity in and the environmental temperature in C e In Out and temperature measures the environmental temperature in C and provides one digital input and one digital output The figure below shows the screen shot illustrating the sensors associated with the SNMP adapter Following a refresh operation all the adapters to which sensors have been connected will be included within the tree structure with an extra indent level and the caption Netman Sensors Select the caption to view the measurements recorded by the sensors and their effective operating status The figure also features an In Out sensor a temperature sensor and a humidity sensor If more than three sensors are connected to the adapter the next three can be viewed by clicking on the button at the bottom right of the screen UPSMON Monitoring Version 5 0 5 Refresh Help v EI a Local Sensor 1 ia 01 Group 01 Digital Input Temperature za UPS o a UPS 02 E UPS 03 Digital Dutput Remote Pa 10110128 Po 10110199 Pa 101 26 Digital Input Temperature Po 1011020 Pa 10110116 BB ce te 10 1 10 124 Digital Output E o E Sensor 2 scl ee sa ae al A aa ft HI fe 10110187 Pe 101 10146 g Methian plus Sensori Metma
36. connection an IP address for the computer or SNMP adapter must be specified for the device where the UPS is connected and the device number usually 1 Note The Windows version supports USB communication via USB UPS adapter The USB communication is supported by MS Windows 95 OSR2 98 2000 and higher Note The TCP IP communication allows the user to specify a remote Upsagent or SNMP adapter location by host name or DNS name It is possible to specify a connection password for each UPS connected This password must always be specified to connect the specific UPS It is possible to specify whether temperature humidity and or digital I O sensors are associated with the SNMP adapter to which the remotely connected UPS is connected This will make it possible to configure the sensors in the right section and activate the relative alarms UPSMON User Manual This field 1s used to specify the parameters for the system shutdown the system Shutdown can be triggered by either a specified time after AC Fail or if the UPS autonomy time is below a System shutdown specified time If the UPS sends a low battery signal to the computer i e the UPS backup time is low the Upsagent will ignore the specified times and start the system shutdown procedure immediately This field can be used to send a shutdown signal to the UPS once all remote computers have UPS shutdown ee shutdown at this point the UPS will then shutdown 1 3 2 Parallel group co
37. correct PRTK code for the UPS to be monitored this code is located on a label which can be found on either the front or the rear of the UPS and failure to input this code will prevent the operation of UPSMON 6 The basic configuration of UPSMON is performed using the Wizsetup program this will enable correct communication with the UPS The full configuration of UPSMON is performed using the Upsetup program this will enable correct communication with the UPS and complete setup of the software operational parameters 10 e Installation of the UPSMON UPSMON User Manual IV Simple UPSMON Configuration Wizard The basic configuration of UPSMON WINDOWS or JAVA version is performed using the Wizsetup program this will enable correct communication with the UPS and setup of the main software operational parameters ATTENTION Bad parameters or undesirable manual changes of the upsmon ini file may cause incorrect operation of the UPSMON software primarily the Upsagent module if Wizsetup for Windows ATTENTION If the Wizsetup program is started for first time the software will require a PRTK code therefore when prompted enter the correct PRTK code for the UPS to be monitored this code is located on a label which can be found on either the front or the rear of the UPS and failure to input this code will prevent the operation of UPSMON AN ATTENTION Administrative rights are required when saving the configuration using Windows NT 2000 Xp
38. ct one of the UPS from the list which is being monitored by the Upsagent module In this case the connection between Upsview and Upsagent is made via the shared memory UPSMON User Manual Uninstallation of the UPSMON e 65 fa Terminal upsview B0x2 1 UPS mnitored by local Upsagent 2 Other UPS A Quit Terminal upsview 80x2 uns Bi hot hot hot hot not hot hot hot hot nor Hot 1 2 5 4 5 6 T g q LH 11 1 L3 Hot Hot n amp not hot y B Quit If the Upsagent is not running on the system it is possible to select a UPS directly by the IP address of the computer or SNMP adapter where the UPS is connected To do this set the IP address and device number usually 1 the Upsview will then try to find the specified system by IP address host names or DNS names are also supported Remote connection made via TCP IP protocol The default UDP port for the Upsagent 1s 33000 66 e Uninstallation of the UPSMON UPSMON User Manual lerminal upsview 6Ux24 s 1 IF ates 2 Device meber 3 Select this UPS 2 2 The displays AN ATTENTION The following screen shots below are only examples and will vary between different UPS system 2 2 1 View Basic The basic information screen shows the UPS name UPS type connection type type of communication protocol status and four status boxes UPSMON Monitoring Version 5 0 6815 L
39. e commands on the connected Ups such as shutdown and reboot Some of these functions depend on the type of monitored Ups Logs used to manage logs file created by Upsmon The logs file must be enabled from Upsetup module Help used to show the help on line Selecting one of the UPS from the Remote tree it is being monitored via TCP IP The default UDP port for the Upsagent is 33000 It is possible to find on the local network all of the agents that are activated at any particular moment without remembering the individual name or address to do this used the Refresh menu It is also possible to select a UPS directly by the IP address of the computer or SNMP adapter where the UPS is connected To do this use the popupmenu that appeared right clicking the mouse on the tree Host names or DNS names are also supported For these Ups there are the following menus 1 Refresh used to find on the local network all of the agents that are activated at any particular moment without remembering the individual name or address View used to switch between various Ups status visualizations There are three visualizations graphic detail and block scheme Functions used to execute some commands on the connected Ups such as shutdown and reboot Some of these functions depend on the type of monitored Ups Help used to show the help on line 56 e Uninstallation of the UPSMON UPSMON User Manual 1 2 Upsview menus 1 21 Refresh Menu o Remote re
40. e same time for the UPS parallel group UPSMON User Manual Advanced UPSMON Configuration e 21 User can add modify or delete parallel groups In the three Parallel groups it will be shown the defined parallel groups By expanding one group it is possible to see the Ups that belong to the group By selecting one parallel group the belonging UPSs will be inserted on the list Groups UPS bara ooi It is possible to add an UPS to a parallel group first select the UPS on the list System groups then press the green left arrow button The new UPS will appear on the list Groups UPS Itis possible to remove an UPS from the parallel group first select the UPS on the list Groups UPS then press the green right arrow button The UPS will disappear from the list Groups UPS Note Each parallel group must contain at least two UPS Defines the redundancy level of the parallel group possible choices are N default N 1 for groups with a minimum of 2 UPS N 2 for groups with a minimum of 3 UPS and N 3 for Redundancy level groups with a minimum of 4 UPS N B A parallel group with redundancy NH will stay active and operational even if 1 UPS within the group fail The load will be shared between the remaining UPS Enable system shutdown if all of the UPS are supplied from the batteries System shutdown parameters for the parallel group can be defined The shutdown may depend on the fact that all the UPS com
41. e the script ups_mess which is used to send messages to users about the UPS status ir UPSMON Configuration Version 3 0 7 System shutdown NOTE Incorrect commands may not provide succesfully shutdown Save files before shutdown Hibernate support only on compatible computers Event list Disable all jobs Action Delay Interv siFile Log event 10 J Execute file 0 Generation event delay sec Communication is lost as Communication is established AC Fail UPS on battery UPS is on line Low battery capacity Normal battery status UPS Output is overloaded UPS Output is normal UPS on bypass UPS return from bypass me Message Communication is lost 34 e Advanced UPSMON Configuration Local message _ Broadcast message system shutdown Email sms Call to Teleguard L Fax message Voice call UPSMON User Manual Parameter name Parameter description When selected the Upsagent will try to save any open files before the system shutdown 1s started This function is not be supported by all programs or some international variant of standard programs Only standard Windows applications are supported e g MS Write MS Office and more Save files before shutdown due to an incompatibility application or conflict with possibly the Save files before shutdown To ensure correct shutdown this may have to be disabled if problems persist 1 ATTENTION If the Upsagent system sh
42. e user from forcing a command to the UPS such as UPS shutdown or test etc HTTP enabled Allow the support for HTTP Disabled HTTP path Used to specify ee Ue Upsagent creates the files with the UPS status for HTTP monitoring If selected the software will require a password for communication ith the UPS This password is to protect the U t connection If Password protection Ki E p mn Disabled the user doesn t know the password it will not be possible to connect the agent 2 2 UPS Configuration l ermin l Up S2TU 80x 4 1 Fi a 4 5 7 i 9 16 1i i 13 an a Farallel functionality The UPS connection window contains the list of the UPS that will be monitored by the Upsagent It is possible to add delete or edit the UPS list The STANDARD version of UPSMON will only allow one UPS to be monitored either locally or via a network by the Upsagent The FULL version will allow one UPS to be monitored locally and up to 15 UPS to be monitored via a network by the Upsagent To change the STANDARD version to the FULL version you must enter the CDROM serial number and relevant License number using the About tab and the enter code dialog box The License number is available from the UPS manufacturer or supplier The FULL version of UPSMON also enables the operation of Parallel functionality This function enables the setup of groups of UPS which are working in redundant operation It is possible to create up to 10 grou
43. ed Ups The colours show the status of the UPS green status means OK and working i e Ups On yellow status means not serious anomalous condition i e Battery On or Bypass On red status means an error or problem i e overload In the section Backup time it is shown the battery autonomy in hours and minutes and the charge percentage of the battery AN ATTENTION the value of autonomy depend on the load of the Ups In the section Time remaining will be shown the effective working time before shutdown system ATTENTION in normal condition line present will be shown In battery on condition and shutdown configuration enabled will be shown the countdown before the shutdown of the system ATTENTION the section Autonomy and Time remaining could be unavailable for some Ups type gt gt In the section States and alarms will be shown Ups states and alarms The difference between states and alarms will be made from the icon place side by side with the text In the graphic Standard visualization will be shown three measures voltage input monofase or threefase load percentage monofase or threefase voltage battery depend on the Ups type In the numeric Detail visualization will be shown all of the detailed information with regards to the measured values from UPS In the block scheme visualization will be shown the internal scheme of the Ups The colors of every UPS block show the s
44. ed actions settings Schedule parameters Device Scheduled action System shutdown amp UPS shutdo Time parameters OneTime dd mm yyyy hh mm Ce Daily hh mm Weekly hh mm Monthly hh mm UPSMON User Manual Advanced UPSMON Configuration e 33 1 7 States and actions In the section System shutdown the user can configure some actions to execute before system shutdown It is possible to launch an external editing program to write a user defined shutdown script Edit script button The user defined shutdown script is executed before the normal system shutdown This can be used for specific commands which will be executed before the shutdown for example stop the web server close some special application or shutdown database server The name of this script is ups_shut however the extension will depend on the operating system ups_shut bat for Windows ups_shut ncf for Novell Netware and ups_shut scr for UNIX s ATTENTION If you specify an incorrect command in the user shutdown script or this command stops not correctly ended then the Upsagent will not provide a correct system shutdown and thus possibly lose some data or a failure on the file system will occur The last command in the user shutdown script must be the command to shutdown of system except Windows versions the shutdown is executed by using the system routines directly from the Upsagent In some operating system it is possible chang
45. endent values fixed time from AC Fail and or specific remaining backup time The Battery Low event causes an immediate system shutdown Direct email support is for Windows only when using other system a script etc must be used to suit the individual system It is possible to specify a name and email address for email recipients in the Configurations page Email a If the Email checkbox is selected then the message is sent to the specified users also by standard Windows MAPI or SMTP interface Before using this option the email service must be configured on the computer sus Eno the option to send the message as SMS to a specified GSM phone number It is possible ss E specify a name and telephone number in the Configurations page The Upsmon can be used to contact a teleservice monitoring and control system with regards to Call to Teleguard the event of the UPS FAX Message Selected when sending a UPS status message via FAX Before using this option the email service must be configured on the computer Selected when making a voice call using a voice modem For each UPS event it is possible to Voice Call create a wav file to describe the event Default Used to reset the event action parameters to the default state Default All Used to reset all of the parameter to the default state 36 e Advanced UPSMON Configuration UPSMON User Manual 1 8 About fe UPSMON Configuration Version 5 0 7 Configurations Schedule
46. ess This menu is available right clicking with the mouse on the tree Used to see the Ups properties such as the UPS name UPS type connection type type of communication protocol some information on the Upsagent or SNMP adapter that monitoring the Ups and some nominal value of the device Ups property Device information Nominal values Device number UPS Mame 5 PATE Code SENTATS607 AU IP address Connection type TCPAIP 10 1 10 128 Software version Nominal power kVA Seral number Password Nominal Power k State On Line Ho Remote system information Nominal Battery Capacity Ah 40 Sa Ene een eT a ere Reese Input Output Configuration ThreephaseT hreephase UPS Type On Line OS version SGP ay version UPSMOM Version 5 0 5 Battery Benches 2 IF address 127 0 0 1 From the popupmenu it is also possible to change the bar color of the graphs in the Standard visualization From the popupmenu it is also possible to select a UPS directly by the IP address of the computer or SNMP adapter where the UPS is connected 8 Insert IP Addr IF address Device number UPSMON User Manual Uninstallation of the UPSMON e 63 1 3 Display for the sensors associated with an SNMP adapter A maximum of six temperature humidity or input output sensors may be connected to the SNMP adapter through the serial port refer to the sensor cable wiring specifications If these sensors are connected the Upsview module can be used to
47. event L 2 Execute file E 3 Local message O 4 Broadcast message B 5 System shutdown S 6 Email E 7 SMS M 8 Call to teleguard 50 e Advanced UPSMON Configuration UPSMON User Manual pr pen ot adro e pes Td RR lerminal upsatup ee 4 Event ation WEET eic events Communication is lost LE DES E Lomanto ion is estab ished AC Foil UPS on battery LEDESE LPS is on Lire PLEGESEPC Low battery copocity Rorm al battery status Outpt UPS is overload utpat UPS is mormal LAS on bypass LEDESEMO LPS return froe byposs 1 Fa a 4 5 7 i 5 lerminal upsetup Sumo g Comuniortion 15 Lost Log event Execute file Local mEssoge EDON DOS BESSOge rem Susto Email ic or No Coll to Teleguard T 18 Default Exit If selected the event will to be logged into event log file If selected the Upsagent will execute a specified command file when a selected condition occurs Execute file Recommendation Always use the full path name for the file If selected this enables message to be displayed on the local computer the messages can be delayed to stop short event changes being displayed unnecessarily e g short power problems or Local message repeated to ensure acknowledgment For Windows the message 1s displayed on the desktop Novell Netware sends the message to the server console and Unix executes the ups loc scr script UPSMON User Manual
48. fresh Used to find on the local network all of the agents remote Upsagent or SNMP adapter that are activated at any particular moment without remembering the individual name or address The refresh will take about ten seconds The IP address of the active agents and the Ups that they controlled will be put in the tree under Remote voice 1 2 2 View Menu Used to switch between Upsview visualizations There are three visualizations graphic Standard numeric detail and Block Scheme ATTENTION The following screen shots below are only examples and will vary between different UPS system Graphic Standard visualization UPSMON Monitoring Version 5 0 5 Refresh View Configuration Functions Logs Help s aja T anal T l a General state Input Voltage go M i i i i i i Li 225YV dj Remote i Pot oy ft say E On Battery 150 160 170 180 190 200 210 220 230 240 250 260 270 260 A Batter Low Load Q Bypass On i i 4 i L 2723 L2 19 QP overload SR CE RL Sn eS ee A SEEE A EEE T gs Overtemp O 10 20 30 40 50 60 70 60 90 100 110 A Alarm 320 350 400 440 460 520 560 600 Autonomy hh mm Other values Frequency Hz Voltage Linet 4 Voltage Line VW Voltage Line3 4 Output 49 9 231 231 230 Bypass Line 49 9 224 224 224 Time remaining States and alarme Communication is OK UPSMON User Manual Uninstallation of the UPSMON e 57 Numer
49. he data logfile for the Minimum size 1 hour measured values Defines the maximum time in hours of the data logfile for the measured values The data logfile will be reset back to the minimum Maximum size i wee 5 hours size value of Minimum size if the logfile contains more data than the configured values When selected the window that appears with the message with regards Autoclose local message window to the UPS status displayed on desktop will automatically be closed only for Windows after 10 seconds if this is not selected the message must be cleared manually by the OK button Enabled UPSMON User Manual Advanced UPSMON Configuration e 17 1 2 Network services ir UPSMON Configuration Version 3 0 7 Main Network services UPS connections Remote sensor Configurations Schedule States and actions About TCP IP service ta Server enabled UDP Port SNMP service Ste _ SNMP enabled HTTP service 2 HTTP enabled WAP service ER WAP enabled Network security Ignore remote UPS commands Password protection Parameter name Parameter description Default TCPAP Service Server enabled Enables or disables Me connection access of other computers running Enabled the Upsagent or Upsview programs TCP IP Service UDP Port The UDP communication port This must be same on all system using 33000 UPSMON All th t for SNMP The data and the status of the U SNMP Service SNMP enabled a ees ca
50. he server console and Unix executes the ups loc scr script If selected this enables a message to be sent to remote users via the network For Windows the message is broadcast to all connected users or only to some users depend on the configuration inserted in the page Configurations for other systems the ups mess scr or ncf for Novell Broadcast message Netware script is executed Recommendation Use the wall command to send message to all connected users on Unix systems If selected this option enables the shutdown of the system for Windows the ups shut cmd file is searched for possible user specified commands before shutdown e g quit databases then the Shutdown system standard system shutdown is executed using the WIN32 API functions For other systems the ups shut scr or cmd or ncf script is started with the appropriate commands to provide the correct shutdown of the computer Direct email support is for Windows only when using other system a script etc must be used to suit the individual system It is possible to specify a name and email address for email recipients in the Configuration tab If the Email checkbox is selected then the message is sent to the specified users also by standard Windows MAPI or SMTP interface Before using this option the email service must be configured on the computer Enables the option to send the message as SMS to a specified GSM phone number The Upsmon can be used to contact a te
51. i aaa SC be monitored via SNMP Allows the support for HTTP The data and the status of the Ups can HTTP Service HTTP enabled be monitored via HTTP through the html static page created by Disabled Upsagent Used to specify where the Upsagent creates the html static page with Empt Per i yee oa the UPS data and status for HTTP monitoring E All th t for WAP The data and the status of the U WAP Service WAP enabled N E A ao be monitored via WAP Enables or disables access from remote computers to make commands to the UPS by Upsagent or Upsview This feature is used to prevent a remote user from forcing a command to the UPS such as UPS shutdown or test etc If selected the software will require a password for communication with the UPS This password 1s to protect the Upsagent connection If the user doesn t know the password it will not be possible to connect Ignore remote UPS commands Disabled Password protection Disabled the agent 18 e Advanced UPSMON Configuration UPSMON User Manual 1 3 UPS connections ir UPSMON Configuration Version 3 0 7 Network services UPS connections Remote sensor Parallel functionality Data update remotes UPS Devices Name PRTK code Connection Serial port IP Address Device ml ups 04 GPSER11201RU Local USB p 1 Delete The UPS connection window contains the list of the UPS that will be monitored by the Upsagent It is possible to add delete or edit the UPS list The S
52. ic visualization Detail _ UPSMON Monitoring Version 5 0 5 Refresh View Configuration Functions Logs Help Gis vue a Local General state Input a E uson ay Remote a Linel 225 sr RA Line Present WA laor Line 3 225 E On Battery Tal Battery Low Voltage 1 EE z i Ling 1 z224 amp Bypass On Line 224 Ling 3 2d Overload E f5 Overtemp Voltage M Bypass Line Output Voltage 1 linet 230 O Alam ine an E Line 3 230 Battery values F Voltage 4 Autonomy hh mr 326 History values anu Func on Inverter h ss Time remaining States and alarms Communication is OR Block Scheme visualization UPSMON Monitoring Version 5 0 5 Refresh View Configuration Functions Logs Help 2 HOR ale H a Local General state urso e tr t On Battery A Battery Low j Q Bypass On Fi Overload Overtemp l A Alarm E Remote Autonomy hhmm Time remaining States and alarms Communication is OR Frequency Hz 43 9 Frequency Hz 50 Frequency Hz a0 Current 4 1 0 Func on Battery h 45 58 e Uninstallation of the UPSMON UPSMON User Manual Sistem values Current 4 25 25 25 nao ce System temp C Load 2 Current 4 2a eli 13 16 ed 2d Oper on Battery Fully discharged ad 33 In the section General State it is shown the Ups complete status The status information depend on the type of monitor
53. ice modem settings 1t 1s possible to configure the voice modem see relative software Voice call configuration Voice modem configurator y gt Allowed Voice call support Voice modem Linea Has Telephone number Delay before play voice sec Humber of retries Parameter name Parameter description 32 e Advanced UPSMON Configuration UPSMON User Manual 1 6 Action scheduler This window 1s used to specify various actions such as UPS shutdown reboot test etc that will be executed at a specified time The maximum number of scheduled actions is 16 The configured actions will be shown in the List of schedule actions list The Next button can be used for showing the actions that will be executed ordered by time a UPSMON Configuration Version 5 0 7 Network services UPS connections Remote sensor Configurations Schedule States and actions About List of scheduled actions UPS Name Scheduled action Time parameters 1 UPS 04 System shutdown amp UPSs Weekly The action can be executed once daily weekly or monthly In the window Scheduled actions settings the user can choose these time parameters and also the type of actions and the Ups on which the action is executed It is recommended to set only one action in same time if multiple action have been specified at the same time some of these actions may be ignored Any actions which are not supported by the UPS will to be ignored schedul
54. in actions can be taken sending an SMS or e mail or system shutdown It is also possible to set parameters for the Input contact so that certain actions are taken sending an SMS or e mail or system shutdown whenever the contact opens or closes One of the actions that can be taken is the closing of the Output contact of the digital I O sensors This can be set to signal a general alarm condition on the UPS e g AC Failure or a general alarm condition on a sensor e g high temperature Up to 32 remote sensors can be configured Given that a maximum of 32 UPS systems can be controlled it is evident that if each UPS has 6 sensors it will not be possible to monitor all the sensors It is up to the user to choose which of the 32 sensors he intends to monitor It is possible to add delete or modify the sensors listed UPSMON User Manual Advanced UPSMON Configuration e 25 1 4 1 Remote sensor configuration Remote sensors configuration Sensor identification A Hame sensor 01 Marco 2 Sensor type Digital 1 0 Ups connection UPS Name Sensor index Temperature thresholds C Down threshold Digital input logic ag Normally open Normally dose Digital output logic as _ Digital output change on sensor alarm _ Digital output change on ups alarm Name of parameter Description of parameter Name of the sensor connected to the SNMP adapter Type of sensor Type of sensor temperature humidity or digit
55. in use you cannot use the powered peripheral connector for tty2 Similarly if tty3 s DB 9 connector is connected to a peripheral the powered peripheral port connected to the tty3 signal lines cannot also be used The powered peripheral ports have the following pin assignments Pin Segnale Nome STEREO Stereo Field Sync amo o Re ebu e Sim n Dev o vs 78 e Communication port specifications UPSMON User Manual 3 4D Compatible Pin Assignments RS 232 The DIN 8 serial port connectors on the Personal Iris 4D 30 4D 35 4D RPC Indigo 4D RPC 50 R4000 Indigo Indy and Indigo 82 have the following pin assignments Pin Segnale Nome a os sumiu O C w eenen Ce es feos O Des f seacoa UPSMON User Manual Communication port specifications e 79 X Troubleshooting 1 General Problem On some Computer Main boards the COM ports are mixed up therefore it is possible that COM 1 under NOVELL is actually COM 2 under NT etc So if any communication problems exist configure the software intentionally on the wrong com port and try again This problem is known from some ASUS Acer GigaByte and SIEMENS Main boards out of production 1997 Ze All operating systems Problem Error message Ups communication lost Answer There is no COM Port available check the COM Port the settings in CMOS and System Setup Problem During the system boot the UPS Management software starts and the UPS turns off Answer To gua
56. inal upsetup 80x24 1 Enable poral lel function 2 Disable action on single UPS 3 Consider a UPS with Lost cossunication a an alare 4 Disable the system shutdom froe a single UPS No 5 Parallel groups a Exit UPSMON User Manual Advanced UPSMON Configuration e 43 Parameter name Parameter description Enable parallel function Enable or disable the parallel functionality A If selected the standard configuration for the single UPS event will be ignored The Upsagent Disable action on single Ups a controls only the group status If it is not selected the Upsagent controls both the group events and also the single UPS events If this parameter is selected the job actions defined in the job dialog box are disabled for the single UPS Consider a Ups with lost If selected the active alarm level is raised specified on the parallel event list for each UPS in communication as an alarm communication lost condition Disable the System shutdown from If selected this disables the system and UPS shutdown time defined on the single UPS a single UPS configuration This function shutdown time is the same time for the UPS parallel group Parallel Groups Used to add modify or delete groups 2 2 4 Parallel Groups The name and UPS number of each parallel group and the events associated to the parallel group are described or configured using the next menu Terminal upsetup 80x 2 4 Pa
57. ix system been indicated correctly The correct Name of the serial port has to be indicated in the menu Upsetup or with the editor in the configuration file Example The entry in the configuration menu could be Ups Connection dev tty01 If the DEVICE exists it can be entered Even if you can enter a DEVICE it does not necessarily mean that this is the one where the UPS cable is plugged in C Is the port directly located at the computer or at a multiplexer or Terminal server Some Terminal server do not give certain interface settings but change the port address after every boot On such a distributor a connection is not possible With Multiplexer 1 only contact information is transmitted d Have you been logged in as root or superuser Login as root and restart E Using Siemens RM models this message appears if the port is unknown or has not been configured at the system installation If RM models have not configured a port you can do this with the termadd command termadd T serial n UPS b motherboard 0 2 d 1 generic Where UPS is the name of the interface for the UPS service dev UPS and motherboard names the location of the interface For motherboard a different device can be used such as the ITP interface distributor or CHASE I OLAN on large RM models The UPS service can also be used on all interface distributors 1f a clear port is dedicated At the command entry motherboard 0 1 O
58. kage primarily used for the Upsagent is performed using the Upsetup module The Upsview module is used for operating and monitoring the active Upsagent module that is connected to the UPS It is possible to check the status of the UPS using various views for example block diagram or alarm tables The Upsview can be used to constantly monitor and evaluate the event file log file which is permanently updated with the changing status of the UPS by the Upsagent UPSMON User Manual What is UPSMON e 5 ll Quick Start Guide 1 Quick start guide to installing the software 1 Make a note of the UPS PRTK code this code is located on a label that will be positioned on either the front or the rear of the UPS e g SENTR Ds If the connection to the UPS is to be made via a serial or USB port install the software and when prompted enter the PRTK code 3 If the connection to the UPS s is to be made via a network using a NetMan adaptor first setup the NetMan following the NetMan user manual the most important information required for the NetMan is the IP address netmask and the router address all of which are entered via option 1 of the Netman main menu screen 4 Enter the PRTK code from note 1 into the Netman via option 5 of the Netman main menu 5 Once the software is installed select Upsetup followed by the UPS configuration tab then enter the PRTK code and the method of communication ensure to use the correct IP address as set
59. l Fa 10110120 Po 10110191 Pa 10 1 10 114 Sensor 3 Digital Input Temperature Humidity Digital Output 8 vo ts NetMan plus Communication is OR Please refer to the SNMP adapter manual for further information on the sensors that can be associated with the adapter ATTENTION this function is active only for remotely connected SNMP adapters In order to see the sensors they must be configured up to a maximum of 32 sensors in the Upsetup module or a Refresh operation executed The threshold settings are active on the sensors configured in the Upsetup module 64 e Uninstallation of the UPSMON UPSMON User Manual Zs Upsview for UNIX When monitoring the UPS using UNIX systems the text version of the Upsview program must be used The style of the displayed screens is dependent on the text interface The text version of Upsview does not support the automatic refresh of the screens if the UPS status changes 2 Connections with Upsagent The Upsview enables the monitoring of a local or remote connected UPS UPS s connected to other computers or SNMP adapters Each Upsview can monitor one UPS but it is possible to start multiple Upsviews to monitor different UPS at the same time lerminal upsview 80x2 UPSAON fonitoring UPSView v 5 8 B81 62 2886 Copyright 2886 UPSAON Monitoring 1 Selected UPS 2 View Basic 3 Event log Dota lig FLActisns A Quit Sele
60. leservice monitoring and control system with regards to Call to Teleguard the event occur on the parallel group The associated event list is the list of simple event that compose the composite event Composite event related to the group is made up of one or more simple events that may occur on the groups UPS The composite event occurs and the defined actions are performed only when all the simple events on the list are verified on the same time A composite event is made up to 6 simple event jerminal upsetuo SOx 4 dssnciated event List 46 e Advanced UPSMON Configuration UPSMON User Manual To add a simple event to the list of the composite events there 1s next menu On this window 1t 1s possible to set also the event priority i e the number of the groups UPS on which the simple event must occur for making it acknowledgeable Terminal upsetup Bx 2 4 gt 1 Concel 2 Event Commjunicotion is lost 3 Priority Event generated for n WS 2 2 3 Message configuration From this menu is possible to configure the modem for the teleservice call the GSM Modem and the WAP support It is also possible to add telephone numbers used by GSM modem for the SMS send ermina l upsetup Blix 4 Hoka configuration gt 1 Enable modem support res 2 Connection serial port 3 4 Primary telephone mmber 4 4 Secondary telephone mmber 5 heber of repeat calls 5 6 Delay bet
61. ministrator Language English i rLogfile registration WV Event logfile enabled Data logfile enabled Log rate sec 5 Bel fa a Minimum size h Lim Maximum size h Sie rLocal message window close Ww Autoclose 54 e Advanced UPSMON Configuration UPSMON User Manual VI Running the UPSMON After the Upsagent service is active the system is protected by the UPS The Upsview is used to connect to the Upsagent service to view the UPS data and to inspect the monitoring process This is also possible via remote access only if TCP IP is installed on the system ATTENTION To confirm if the Upsagent is running and the system is protected access the system utility for a list of operating processes For UNIX use the command ps and for Windows confirm that the icon on the toolbar is present usually bottom right or left of the desktop if Upsview for Windows 1 1 Connecting with Upsagent The Upsview enables the monitoring of a local or remote connected UPS UPS connected to other computers or SNMP adapters Each Upsview can monitor one UPS but it is possible to start multiple Upsviews to monitor different UPS at the same time In the tree will be shown all selectable Ups The tree is divided in two section Local to monitored Ups connected to the local Upsagent Remote to monitored Ups connected to other remote Upsagent or remote SNMP adaptors UPSMON Monitoring Version 5 0 5 Refresh View Configuration F
62. ms the events are also logged into the Log event 1 ATTENTION On Windows NT 2000 or XP platforms the events are also logged in the system log this depends on system configuration see syslog manual If selected the Upsagent will execute a specified command file when a selected condition occurs E te fil ds Recommendation Always use the full path name for the file UPSMON User Manual Advanced UPSMON Configuration e 23 Local message Broadcast message Shutdown system SMS Call to Teleguard FAX Message Voice Call If selected this enables message to be displayed on the local computer the messages can be delayed to stop short event changes being displayed unnecessarily e g short power problems or repeated to ensure acknowledgment For Windows the message is displayed on the desktop OS 2 executes the ups loc cmd script Novell Netware sends the message to the server console and Unix executes the ups loc scr script If selected this enables a message to be sent to remote users via the network For Windows the message is broadcast to all connected users or only to some users depend on the configuration inserted in the page Configurations for other systems the ups mess scr or ncf for Novell Netware script is executed Recommendation Use the wall command to send message to all connected users on Unix systems If selected this option enables the shutdown of the system for Windows the ups shut cmd file is searched for po
63. nfiguration select the Configure button Groups configuration Main properties of parallel functionality Enable parallel function al Disable action on single UPS Ww Consider a UPS with lost communication as an alarm Disable the system shutdown from a single UPS Parallel groups ig 01 Group U1 Level of redundancy a al Groupe UPS System UPS a pee UPS Name PATE code UPS Name PATE code UPS 01 SENTATSBOT RU UPS 01 SENTATSB0T RU UPS 2 SENTATSBOT RU UFS 02 SENTATSBOT RU Enable the system shutdown if all UPS are on battery Delete _ Enable the system shutdown if the autonomy is low Parameter name Parameter description Enable parallel function Enable or disable the parallel functionality If selected the standard configuration for the single UPS event will be ignored The Upsagent controls only the group status If it is not selected the Upsagent controls both the group events and also the single UPS events If this parameter is selected the job actions defined in the job dialog box are disabled for the single UPS Disable actions on single Ups Consider a Ups with lost If selected the active alarm level is raised specified on the parallel event list for each UPS in communication as an alarm communication lost condition Disable the System shutdown from If selected this disables the system and UPS shutdown time defined on the single UPS a single UPS configuration This function shutdown time is th
64. oing and interpreting parameters can also be set Special files for the serial ports exist in the dev directory These files tty dfm 1 56 are created automatically when the system software is installed Each port is referred to by three different names represents the port number Some drivers are used for directly connecting simple devices including most terminals others for the use modem control signals and more for devices that understand hardware flow control signals UPSMON User Manual Communication port specifications e 77 There are four different types of connectors found on various 4D models The DB 9 serial port connectors which are found on the Challenge Onyx Personal Iris and PowerSeries machines have the following pin assignments Signal Name Transmit Data Request to Send pos RR ooo pom 8G Simairua os peo DataCarier Detect S O om Data Terminal Ready S The Challenge and Onyx systems supply an RS 422 port This RS 422 port uses a DB 9 serial connector that have the following pin assignment Pin Signal Name Dao oo foca OOOO Deo so Jimi De o oon freedutm OOOO Do ts frutos OOOO O In order to support peripherals which draw power from the host system the Challenge and Onyx systems provide two powered peripheral serial ports These ports have a DIN 8 connector The powered ports share the tty2 and tty3 signal lines with the standard DB 9 connectors if the DB 9 connector for tty2 is already
65. on these are as follows NAME The UPS or Group name will be added to the message See main parameters dialog box S YSNAME The System name will be added to the message See main parameters dialog box S YSLOC The System location will be added to the message See main parameters dialog box SHUTTIME The time before shutdown of the local system in seconds SHUTTIMEI The time before shutdown of the local system in the format hh mm ss STH STM e STS The three values the time before the shutdown of the local system in hours minutes and seconds REMTIME The remaining UPS battery autonomy REMCAP The remaining UPS battery capacity SENSORNAME Name of the sensor on which the event occurred Valid only if events have been associated with the sensors Message If selected the event will to be logged into event log file system Application event log On UNIX platforms the events are also logged into the Log event ATTENTION On Windows NT 2000 or XP platforms the events are also logged in the system log this depends on system configuration see syslog manual If selected the Upsagent will execute a specified command file when a selected condition occurs Execute file Recommendation Always use the full path name for the file UPSMON User Manual Advanced UPSMON Configuration e 35 If selected this enables message to be displayed on the local computer the messages can be delayed to stop short event changes being dis
66. ote for UNIX operating system it is possible to send email message adding the command in the script ups_eml scr Enables the option to send the message as SMS to a specified GSM phone number It is possible to specify a name and telephone number in the Configurations Message menu The Upsmon can be used to contact a teleservice monitoring and control system with regards to Call to Teleguard the event of the UPS The number of the teleservice company can be inserted in the Modem Configuration Menu It is possible to alter the default message for a particular event It is not recommended to change the basic message text as this may cause an incorrect message to be sent which does not correspond to the actual event Note in the message text it is possible to add actual values or information which will be displayed along with the original information these are as follows NAME The UPS or Group name will be added to the message See main parameters dialog box SYSNAME The System name will be added to the message See main parameters dialog box SYSLOC The System location will be added to the message See main parameters dialog box SHUTTIME The time before shutdown of the local system in seconds SHUTTIMEI The time before shutdown of the local system in the format hh mm ss Message STH STM e STS The three values the time before the shutdown of the local system in hours minutes and seconds REMTIME The remaining UPS
67. own shutdown at this point the UPS will then shutdown 2 2 2 Ups Connection The UPS connection must be set to the chosen method to be used for the communication between the computer and UPS s The first method of connection is local this connection method is used when the connection to the UPS is to be made via a serial port if this method is to be used ensure that the correct serial port and UPS address is selected All the other settings for the serial connection baud speed etc are automatically set for the selected UPS type The second method of connection is remote via a network for this connection an IP address for the computer or SNMP adapter must be specified for the device where the UPS is connected and the device number usually 1 42 e Advanced UPSMON Configuration UPSMON User Manual Note The Windows version the Linux version the Solaris version and the Mac OS X version supports USB communication via USB UPS adapter Note The TCP IP communication allows the user to specify a remote Upsagent or SNMP adapter location by host name or DNS name Note It is possible to specify a connection password for each UPS connected via TCP IP This password must always be specified to connect the specific UPS Terminal upsetup SUx 24 gt 1 Connection Local Commection serial port Adress a IP Address JEY ICES tassvord protection 2 3 1 Enter or modify password 2 2 3 Parallel functionality Term
68. played unnecessarily e g short power problems or Local message repeated to ensure acknowledgment For Windows the message is displayed on the desktop OS 2 executes the ups loc cmd script Novell Netware sends the message to the server console and Unix executes the ups loc scr script If selected this enables a message to be sent to remote users via the network For Windows the message is broadcast to all connected users or only to some users depend on the configuration inserted in the page Configurations for other systems the ups mess scr or ncf for Novell Broadcast message Netware script is executed Recommendation Use the wall command to send message to all connected users on Unix systems If selected this option enables the shutdown of the system for Windows the ups shut cmd file is searched for possible user specified commands before shutdown e g quit databases then the standard system shutdown 1s executed using the WIN32 API functions For other systems the ups shut scr or cmd or ncf script is started with the appropriate commands to provide the correct shutdown of the computer ATTENTION System shutdown conditions defined in the UPS connection dialog box Shutdown system is not dependent on this checkbox ATTENTION You cannot specify a Shutdown system action for AC Fail or Battery low these are dependent on the UPS connection configuration The system AN shutdown time after AC Fail may be defined by two indep
69. prising the parallel group are operating in battery mode The shutdown may depend on the fact that the i th backup time of the parallel group selected is lower than the preset time N B If the redundancy level is N the lowest backup time is considered if it is N 1 the second lowest time is considered if it is N 2 the third lowest time is considered while if it is N 3 the fourth lowest time is considered Enable th h f e ADE eee td It is possible to shutdown the groups UPS together with the system after the specified delay system shutdown It is possibile to define a set of actions related to states or events for each parallel group In order to configure these actions it is necessary Enables system shutdown in the event of low back up time to select the parallel group and to press the Jobs button Jobs configuration for parallel group Jobs configuration Parallel group E ig Associated event list Event list a Evert Priority Communication is lost 3 RS Re ae All Communication ig established aaa AC Fail UPS on battery Communication ig establis Exact ES cama Low battery capacity Activated jobs for parallel group Normal battery status UPS Output it overloaded UPS Output i normal Sf Event 1 Event 01 UPS on bypass Event Message Acton Interv 5 File Log event Execute file Local message _ Broadcast message System shutdown Email o Call to Teleguard _ Fax mess
70. ps with each group containing up to 8 UPS 2 UPS minimum with up to 64 event actions To enable this function the user must define at least 2 Ups UPSMON User Manual Advanced UPSMON Configuration e 41 2 2 1 UPS definition lerminal upsetuo OA 4 UPS configuration LPS Home FRIE code PERLI UPS Serial Mmber Connect Lon Shee shuldo F 1 Delay after start AC Fail mina Dystea shutdown E 1 If autoromy bime iz below than min UPS shutdown Yel Delay 220 Exit Parameter name Parameter description UPS Name UPS identification name The PRTK is used to determine the type of UPS to be monitored the code to be entered can be PRTK Code located on the UPS The UPS have unique serial numbers this number used to identify the UPS Enter the serial number as printed on the UPS identification label This field is important for the correct operation with Teleservice program UPS Serial number This field is used to specify the parameters for the system shutdown the system Shutdown can be triggered by either a specified time after AC Fail or if the UPS autonomy time is below a System shutdown specified time If the UPS sends a low battery signal to the computer i e the UPS backup time is low the Upsagent will ignore the specified times and start the system shutdown procedure immediately This field can be used to send a shutdown signal to the UPS once all remote computers have PS sh UPS shutd
71. r the UPS to be monitored this code is located on a label which can be found on either the front ATTENTION If the Wizsetup program is started for first time the software will require a PRTK code therefore when prompted or the rear of the UPS and failure to input this code will prevent the operation of UPSMON The basic configuration of UPSMON performed using the Wizsetup program is due in three step Is possible to open the configuration complete program Upsetup by clicking the button with the caption Upsetup l Welcome page in this page is possible to select the language of UPSMON 08e Upsmon Wizard Setup 5 0 2 Welcome to the Wizard version of the Upsmon Setup This Wizard configures the main parameters for the Upsmon Features configuration of the Ups and its connection configuration of the system and Ups shutdown Language Select language English 9234 ay Upsetup dm Back E Next x Cancer PA UPS Configuration page in this page is possible to configure UPS parameters and the connection parameters to use to communicate with UPS UPSMON User Manual Simple UPSMON Configuration Wizard e 13 Upsmon Wizard Setup 5 0 2 Ups Configuration Ups Data a Ups Name UPS 01 PRTK Code GPSER 11201RU Ups Connection f Local Serial Port USB Er gt Remote IP Address EE upsetup qa Back mb Next cance E Upsetup SD Back SP Next O Cancr 3 Shutdown p
72. rallel group i Camel 2 Nome 3 Level of redundancy Mi 4 Enable the systea shutdown if the qutonosy is low 4 1 Autonosy Threshold min 5 Enable the systea shutdom if all UPS are on battery K i System shutdown delay mind ee the UPS shutdom after systea shutdom 6 1 UPS shutdown delay Sec ie 7 Groups UPS O Activated jobs for parallel group q Load Jobs 18 Sore Jobe a Exit A group name must be specified a minimum of two UPS added from the list of UPS monitored by Upsagent shown by selecting Groups UPS and configured the selected actions for the group events Parameter name Parameter description Defines the redundancy level of the parallel group possible choices are N default N 1 for groups with a minimum of 2 UPS N 2 for groups with a minimum of 3 UPS and N 3 for Redundancy level groups with a minimum of 4 UPS N B A parallel group with redundancy N 1 will stay active and operational even if 1 UPS within the group fail The load will be shared between the remaining UPS The shutdown may depend on the fact that the i th backup time of the parallel group selected is lower than the preset time N B If the redundancy level is N the lowest backup time is considered if it is N 1 the second lowest time is considered if it is N 2 the third lowest time is considered while if it is N 3 the Enables system shutdown in the event of low
73. rantee the correct function of UPSMON Software use the default settings for the UPS model or the serial port type this problem can also be caused by a wrong cable connection Problem In the logfile of UPSMOM the message Communication lost communications restored occurs Answer Some of the data from the UPS is not correct or the bytes of software received where damaged This may be the result of external effects on the cables or the UPS Check the cable cable length and the communication parameters Check if any background software that is using the com ports is active e g Virus checker within NetWare or others If this message occurs periodically it is not a critical event Only if this message occurs continuously for a longer period should you contact the UPS software hardware support 3 Troubleshooting Novell NetWare Problem ASUS P5HX B series 1997 does not accept any NOFIFO Parameters at NOVELL AIOCOMX Commands Answer Node Parameter Problem with Novell NetWare If AIOCOMX is installed and responds with the message loaded aiocomx 2F8 on port 36789690 the node parameter e g NODE 1 has to be specified otherwise the serial port will not work Problem The UPSMON Software could not establish the communication to the UPS Answer You may have configured a port which is not found by aiocomx nlm Check the ports offered by aiocomx nlm Pay attention to the screen display when starting aiocomx nlm If aiocomx nlm has been star
74. rive mounted Problem How can I shutdown my database 1 e within the ups exe shell Answer Itis sufficient to edit the ups shut scr file and write the command of database shutdown Problem Unix problem with HP Netserver LC2 Answer Please switch the remote access in the BIOS to disabled otherwise a UPS communication is not possible because the same IRQ is used as with the TTY port Problem Upsagent does not start communication lost Answer This error occurs only with cable serial setting Possible Problems You are using the wrong device cable or adapter between the computer and cable If you are using an IRIX server you often need a adapter it to connect the computer to UPS Mini DIN to D SUB 9 With the IRIX serial com port description below you can check if you are using the correct one UPSMON User Manual Troubleshooting e 81 Problem Answer Problem Answer Problem Answer Problem Answer Problem Answer Problem Answer Problem Answer 82 e Troubleshooting A false alarm by the Upsagent happens in constant intervals Is the port free meaning that no getty processes are active No Login must run on this port In the file inittab respawn has to be overwritten with off When I start the ups shut scr script I get a syntax error Change default shell to sh The configuration menu can not be read at the terminal type 978x of a Siemens comp
75. rwise use a DOS or Windows workstation on your network insert the CD into this machine Now copy the software e g via FTP to the hard disk of the Unix system Make a copy of the complete Unix directory ATTENTION When configuring Upsmon on a platform which can support JAVA environment v1 4 or higher it is possible to use the JAVA version of Upsetup For these platform it is possible to use also the wizard JAVA Wizsetup that perform a basic configuration to ensure a correct communication with the UPS 2 3 Novell Netware l The Installation must be started from an MS Windows workstation that is connected to the server by a user with administrator rights 2 To install UPSMON start the SETUP EXE program located on the installation CD 3 When prompted select the destination folder for the program files 4 The Installation program will automatically copy all of the necessary files and create a program group however a shortcut to start the Upsagent module must be created in Autoexec ncf by system utility Install or NwConfig UPSMON User Manual Installation of the UPSMON e 9 5 After successfully installing the software the Upsetup program will start automatically when prompted enter the correct PRTK code for the UPS to be monitored this code is located on a label which can be found on either the front or the rear of the UPS and failure to input this code will prevent the operation of UPSMON 6 The configuration of UPSMON is performed
76. s 1 8 About 2 Upsetup for UNIX 2 1 General parameters 2 2 UPS Configuration Did Message configuration 2 4 Scheduler 29 Job configuration 3 Upsetup for Novell Netware Upsetup for JAVA and Mac OS X VI Running the UPSMON 1 Upsview for Windows 1 1 Connecting with Upsagent 1 2 Upsview menus 1 3 Display for the sensors associated with an SNMP adapter 2 Upsview for UNIX 21 Connections with Upsagent 2 2 The displays 3 The Upsview for Novell Netware 4 The Upsview for JAVA and Mac OS X VII Uninstallation of the UPSMON 1 Uninstall procedure for Windows ON VO 0O U YN NY N 11 11 13 15 15 16 18 19 25 27 33 34 37 38 39 41 47 49 50 53 54 55 55 55 a 64 65 65 67 72 73 74 74 UPSMON User Manual Contents e iii e JR 4 VIII 1 2 IX L 2 3 X I 2 3 4 ai iv e Contents Uninstall procedure for UNIX Uninstall procedure for Novell Netware Uninstall procedure for Mac OS X Configuration for expert users Manual changes of the UPSMON INI parameters Console execution of Upsagent Communication port specifications RS 232 specifications IRIX serial communication ports 4D Compatible Pin Assignments RS 232 Troubleshooting General All operating systems Troubleshooting Novell NetWare Troubleshooting Windows Troubleshooting UNIX 74 74 74 75 75 75 11 1 T11 79 80 80 80 80 81 81 UPSMON User Man
77. s workstation which was used for the installation Otherwise all of the files must be deleted manually It is possible to uninstall using the standard uninstall procedure for Windows designed applications For example via the Control Panel Add and remove programs or it is possible to use the uninstall icon in the UPSMON program group Finally ensure that the startup shortcut for the Upsagent from Autoexec ncf is deleted 4 Uninstall procedure for Mac OS X To uninstall from Mac OS X use the script uninstall upsmon command on the upsmon directory this can only be executed with root rights 74 e Uninstallation of the UPSMON UPSMON User Manual Vill Configuration for expert users 1 Manual changes of the UPSMON INI parameters The UPSMON INI configuration file includes some fields that are possible to modify by editing the file SYSTEM section System OEMMode 0 1 Enables the configuration menu and the functions menu 4 Disables the display of the Upsagent icon on the task bar It is possible to use a combination of these i e 1 2 3 DebugMode 0 1 Enables the view of some extended parameters in the debug mode 3 Decodes the entire UDP packet in the TCP IP communication ShutdownType 1 O Executes only the system shutdown computer with AT power supply 1 Default executes system shutdown and turns off the computer power supply ATX power supply In the SERIAL 00 section Serial 00 CheckRate 1 Enables the time be
78. sing the jobs configuration menu it is possible to launch an external editing program to write a user defined shutdown script The user defined shutdown script is executed before the normal system shutdown This can be used for specific commands which will be executed before the shutdown for example stop the web server close some special application or shutdown database server The name of this script is ups_shut scr for the UNIX system ATTENTION If you specify an incorrect command in the user shutdown script or this command stops not correctly ended then the Upsagent will not provide a correct system shutdown and thus possibly lose some data or a failure on the file system AN will occur The last command in the user shutdown script must be the command to shutdown of system except Windows versions the shutdown is executed by using the system routines directly from the Upsagent In some operating system it is possible change the script ups mess which is used to send messages to users about the UPS status Terminal upsetuo 80x24 Disable all jobs Mo Event action WEET basic events Event action sormager other events Default All Edit script Exit Action name Action description Disable all jobs Enables or disable all of the jobs 1f selected no jobs can be executed Default All Used to reset all of the parameter to the default state For each event it is possible to set an action from the list below 1 Log
79. ssible user specified commands before shutdown e g quit databases then the standard system shutdown 1s executed using the WIN32 API functions For other systems the ups shut scr or cmd or ncf script 1s started with the appropriate commands to provide the correct shutdown of the computer Direct email support is for Windows only when using other system a script etc must be used to suit the individual system It is possible to specify a name and email address for email recipients in the Configuration tab If the Email checkbox is selected then the message is sent to the specified users also by standard Windows MAPI or SMTP interface Before using this option the email service must be configured on the computer me Enables the option to send the message as SMS to a specified GSM phone number The Upsmon can be used to contact a teleservice monitoring and control system with regards to the event occur on the parallel group Enables the option to send the message as FAX Before using this option the fax service must be configured on the computer Selected when making a voice call using a voice modem For each UPS status 1t 1s possible to create a wav file to describe the event It is possible to save the UPS parallel event configuration and also possible to load it on another computer without re inserting the same configuration this can be done using the Save profile and Load profile buttons 24 e Adv
80. ta logfile for the measured values The data logfile will be set back to the minimum size Maximum size m a 5 hours value of Minimum size if the logfile contains more data than the configured values 2 1 1 Network services Terminal upsetuo 80x24 Network Services Update frequency mec Server enabled Yes LDP Port T Ignore remote UPS comman HTTP eran led 0 HTTP Path Password protection Mo Yel Enter or modify password Exit Parameter name Parameter description Default Defines the time interval in seconds in which the Upsagent polls for data from the UPS if the Upsagent is connected to remote UPS via network The system speed may be reduced due to permanent Update frequency communication with the UPS if this value is too small If the value is 3 seconds too high the system will react slower in the case of an alarm from the UPS The recommended values are from 1 second for smaller networks or 5 10 seconds on larger networks Enables or disables the connection access of other computers running Server enabled l Enabled the Upsagent or Upsview programs 40 e Advanced UPSMON Configuration UPSMON User Manual UDP Port The UDP communication port This must be same on all system using UPSMON Enables or disables access from remote computers to make commands to the UPS by Upsagent or Upsview This feature is used Ignore remote UPS commands Disabled to prevent a remot
81. tatus of the UPS and if a situation with the UPS or the system is critical Green means OK and working Grey means that the object is present but not in use at the moment Yellow means a not serious anomalous condition Red means an error or problem has occurred with this object 1f any values are critical a system shutdown and or technical service may be required If the parallel groups have been configured see Upsetup a summary list of all the UPS within a group can be displayed by selecting the name of the parallel group from the local tree structure The top of the screen shows the status of all the UPS modules belonging to the group taken from the General Status section of each UPS The graphic shows the load supported by the UPS within the group and calculated as the average of the loads shared between the group UPS modules The graphic also shows another transparent bar which shows a projection of the load supported in the event of loss of group redundancy e g if a parallel group comprising of three UPS modules has a redundancy level of N 2 the transparent bar will show the load that the remaining UPS module would have to support should the other two redundant modules fail The Backup time section shows the battery backup time in hours and minutes as well as the battery charge percentage of the UPS which has the lowest backup time for redundancy level N or the UPS with the second lowest time for redundancy level N 1 the
82. ted unload aiocomx nlm and start it again to check the parameters Check if other modules are using aiocomx nlm like fax software time synchronising modules etc Problem I receive the error message Loader cannot find public symbol Answer Has SNMP been loaded before the start of the UPS service Check the SNMP Version From version 2 08 on communications is possible Please use a CLIB NLM that is able to work with SNMP NLM Problem I receive the error message Communication lost Answer Upsagent can not identify the protocol 80 e Troubleshooting UPSMON User Manual Solutions a Has an original Novell NetWare aio or aiocomx driver been used Some fax software products e g Faxware have their own aio modules for serial communication which do not correspond with the NetWare standard and overwrite the original drivers Is the port of the system ok In certain cases the port is unable to support the standard for NetWare aio and aiocomx especially with ports on board with a 16550 components Replace the aio and aiocomx mo dules with up to date drivers or try a manual start of the ailocomx modules with the parameter nofifo load sys system aiocomx nofifo Is the communication speed for aiocomx too high Set the UPS on a communication rate of 2400 or 1200 baud if your UPS supports this and test it again If you can t reduce the communication speed of your UPS model set the parameter for arocomx to ma
83. the scheduled actions Using this function it is possible to specify various actions such as UPS shutdown reboot test etc these actions will then be executed at a specified time It is recommended to set only one action in same time if multiple action have been specified at the same time some of these actions may be ignored Note The maximum number of scheduled actions is 16 The Next actions function can be used for showing the actions that will be executed ordered by time List of scheduled actions ups GL Hot def ined Rot defined Not def ined Rot defined Not defined Hot def ined Hot defined Rot defined Rot defined Not def ined Hot defined Not def ined Not defined Hot defined 16 Mot defined ee ee mn ces 17 Nest octione Exit The action can be executed once daily weekly or monthly In the menu Schedule parameters the user can choose these time parameters and also the type of actions and the Ups on which the action is executed Any actions which are not supported by the UPS will to be ignored Terminal upsatup 80x24 uns Bl UPS shutdom Daily 18 43 UPSMON User Manual Advanced UPSMON Configuration e 49 2 5 Job configuration The jobs configuration menu is used to define the jobs that will be executed when an event of the UPS occurs It is possible to configure multiple jobs for a particular event It is possible to execute an external command defined by the user U
84. third lowest time N 2 or the fourth lowest time N 3 The Remaining time section shows as when there is no parallel group the effective operating time remaining before the system shuts down The Other Values section shows the voltage current and frequency values of the parallel group The frequencies and voltages are the same for all the UPS modules within the group while the current values represent the sum of the currents present on each UPS in the group UPSMON User Manual Uninstallation of the UPSMON e 59 UPSMON Monitoring Version 5 0 5 Refresh Help elo E ET Local ig 01 Group 01 urso UPS 02 UPS 03 E Remote upsot ursos 7 UPS 03 E A if i j On Battery On Battery On Battery Battery Low Battery Low Battery Lowy als 6 6 amp Bypass On Bypass On Bypass On Overload Overload Overload E Oyvertemp Oyvertemp Overtemp gt E Alarm Alarm Alarm Autonomy hmm A My E O A E R ES O O L E E L E 0 10 20 30 40 50 60 70 680 90 100 110 Time remaining Other values F Hz Li ty L2 L3 4 Li A L2 A Input 499 225 ae der 55 55 Output 50 230 231 230 ae 34 Bypass Line 50 226 224 226 1 2 3 Configuration Menu Configuration Used to launch the Upsetup module ATTENTION this menu is available only for Ups monitored by local Upsagent 1 2 4 Functions Menu
85. tup that allow a basic software configuration NOTE To confirm the correct installation on Windows NT 2000 Xp and 2003 Server it is possible to view a list of all installed AN services in the Control Panel Services NOTE The destination PC must have Windows Installer in order to run the installation package 2 2 UNIX 1 To install UPSMON insert the UPSMON CDROM and execute the MOUNT command to access the included file There are several specific options for this command these option are dependent on the different versions of UNIX for example the configuration for the file authorisation the filename written in upper or lower case etc The following table describes specific options for the specific UNIX operating systems Options Device name Lin o mode 777 t 1509660 dev cdrom Where id is the SCSI Id There are two possible case modes for filenames on the CD ROM all filenames are either upper or lower case This must be noted when you name the installation program or when you change the subdirectory at the CD ROM The ISO9660 specification supports also version numbers of filename therefore on some systems you will mon wow find suffixes semicolon or dot with filenames As you can abbreviate filenames with wildcards you shouldn t have any problems with this feature ATTENTION Sometimes it is necessary to change using the CHMOD command the execution rights of the install script or other scripts
86. tween one request and the next for the serial communication to be incremented This is important 1f there 1s communications loss due to a slow computer 2 Console execution of Upsagent The Upsagent service can be executed using various parameters gt debug to view all the data flow between the program and the UPS gt log to save the data flow shown in the file debug log The file created can be used to solve any problems with the communication In Windows there are others parameters gt start to start the service gt stop to stop the service gt install to write the service in the Windows configuration registry gt remove to cancel the service from the Windows configuration registry UPSMON Manuale Utente Configurazione per utenti esperti e 75 IX Communication port specifications k RS 232 specifications 25 pin contact male at the computer end Pin Signal Name Da os frmansma DE om omtemmanas 5 06 found 9 pin contact male at the computer end Pin Signal Name Da om outemnana OO Do os ousar OOO EO fers onsa Doing 2 IRIX serial communication ports All IRIS 4D Series machines have two or more general purpose serial ports These ports may be used to connect terminals printers modems other machines or graphical input devices such as a tablet or dial and button box Each line may be independently set to run at speed as high as 19 200 or even 38 400 bps Various character ech
87. ual What is UPSMON The UPSMON software package is a client server application for networks and local workstations used for monitoring UPS systems The server module of the UPSMON Software is the Upsagent this communicates via an RS 232 or TCP IP network cable with the UPS When the Upsagent is operating it collects as a background program the messages sent from the UPS The Upsagent interprets the received messages and makes them available to the client module which is known as Upsview The communication of the data between the Upsagent and the Upsview can be done either via TCP IP or shared memory on a local computer If the Upsagent detects mains supply voltage variations or even a total power loss it can execute various command scripts which for example may either perform a shutdown of the server or send warnings to the connected users These scripts which are a part of the UPSMON package can be adapted to suit your specific requirements When a change in the UPS alarm status is detected there is a corresponding file i e shell script command file that will be executed either when the alarm is activated or deactivated If an alarm condition remains for a long duration the user can customise the system to shutdown The user may also prompt the UPS to shutdown to save autonomy time which allows the system adequate time to enable further shutdowns in the unfortunate event of a repetitive alarm condition The configuration of the UPSMON pac
88. unctions Logs Help ielmna ga o SJ Local General state Input voltage os Lins Present T On Battery A Battery Low Load 7 x RA Bypass Un i i i 1 23 L2 19 io Overload E i L 29 TSERE EEE STC E T E TASE ESES EE ETE TATT R TE EERE UT i al Overtemp D 10 20 30 40 50 60 70 60 90 100 110 Battery Volta AY Alarm Poe E Remote EEE EEE EA ED E EEE EEE EFE A 200 240 26 320 360 400 440 450 520 560 600 Autonomy hmm Other values e Frequency Hz Voltage Line1 1 Voltage Line W Voltage Line3 W Output 49 9 231 231 2a Bypass Line 49 9 224 224 224 Time remaining States and alarm Communication is OK Selecting one of the UPS from the Local tree it is being monitored by the Upsagent module running on the same computer In this case the connection between Upsview and Upsagent is made via the shared memory In the Local tree will be shown all the Ups configured in the Upsetup module eventually with the parallel groups defined For these Ups there are the following menus Refresh used to find on the local network all of the agents that are activated at any particular moment without remembering the individual name or address 2 View used to switch between various Ups status visualizations There are three visualizations graphic detail and block scheme 3 Configuration used to open the Upsetup module UPSMON User Manual Uninstallation of the UPSMON e 55 Functions used to execute som
89. uration gt 1 Generol porgeeters 2 UPS configuration 3 Messages configuration 4 Schedule 5 Abe conf igration a Exit 2 1 General parameters lerminal upsetup Bbw 2 4 gt 1 Systems ME Systems Location d Hsia Gonbact 5 Event Logfile enabled res 6 Dota logfile enabled Ro 6 1 og rate S60 6 2 ininum size ho 6 5 daxinum size h T Network Services Defines the name of the local system Server System location Defines the location of the local system Server room UPSMON User Manual Advanced UPSMON Configuration e 39 System contact Defines the contact persons name for the local system Administrator Language selection All messages and text in UPSMON except some Ea ri Language system messages is described in lang_xx ini files The default is language lang 00 1m used for the standard English language interface Event Idetilomenabled Enables or disables the use of the event logfile for logging the events Enabled by the Upsagent module Data logfile enabled Enables or disables the use of the data logfile for measured values by Disabled the Upsagent module Defines the interval in seconds in which the Upsagent writes the Log rate 5 seconds measured values into the data log file ne Defines the minimum time in hours of the data logfile for the Minimum size 1 hour measured values Defines the maximum time in hours of the da
90. using the Upsetup program this will enable correct communication with the UPS and setup of the software operational parameters ATTENTION After the installation it is possible to configure the UPSMON using the Windows programs Upsetup exe and Upsview exe or it is possible to use NLM module Upsetup nim and Upsview nim directly on the server console ATTENTION To successfully start the Upsagent on some systems a successful start of UPSMON is required This system NLM modules must be started before you start the Upsagent or Upsview module AIOCOMX NLM for specified serial port and TCPIP NLM For more details consult the system user manual As As ATTENTION The standard version of UPSMON for Novell Netware only supports Novell Netware 4 x and 5 x For Novell Netware 3 12 you must use the special version of UPSMON located in directory 312 2 4 Mac OS X 1 The installation must be performed by a user with root rights 2 To install UPSMON start the file Setup dmg sit on the installation CD the program will unpack the installation package Upsmon pkg 3 Select and execute the package 4 The installation program will automatically copy all the necessary files and create on the Applications directory 3 new icons for the viewer configuration program and wizard The Upsagent module will startup automatically at the next reboot 5 After successfully installing the software the Wizsetup program will start automatically when prompted enter the
91. utdown does not work correctly it may be When selected it enables the possibility to suspend the system instead of a normal shutdown Hibernate support aut This function is supported by Windows 2000 and higher on supported hardware In the List of events section the user may define the actions to be taken when a given event is detected on the UPS or on the sensors connected A number of actions can be associated with a particular event on the UPS or on the sensors connected such as for example the possibility of executing a series of external commands defined by the user A runtime delay can be programmed for the actions associated with a particular event so as to filter events that only last for a short time Similarly an interval can be programmed for the repetition of the action should the associated event still be active Both values are expressed in seconds Action name Action description Disable all jobs Enables or disable all of the jobs 1f selected no jobs can be executed Generation event delay The event that occurs 1s recognized by Upsmon only after the specified delay It is possible to alter the default message for a particular event It is not recommended to change the basic message text as this may cause an incorrect message to be sent which does not correspond to the actual event Note in the message text it is possible to add actual values or information which will be displayed along with the original informati
92. uter For a correct screen display the baudrate has to be set to 9600 19200 The message Write error on dev or TCSAGET error on appears Especially with IBM AIX a clocal has to be entered in the SMIT configuration menu in the boot default settings of the interface that should be used by the UPS The interface should be without modem control signals and no hardware handshake After changes are made in the Upsetup menu the Upsagent starts unchanged Changes have been made in the ups_conf menu but a running Upsagent has not taken over the changes Stop the daemon and restart Some files on the CD ROM are not displayed in the correct way or the install script ends abnormally Mount the CD ROM as case sensitive Check the correct mount commands for your system E g HP UNIX may use mount o cdcase lt device gt lt mountpoint gt or DEC ALPHA OSFI V 3 2 mount t cdfs o noversion dev rz6c cdrom2 rz Disktyp 6 SCSI address c partition c for total SINIX mount F hs dev iosO sdiskO05s0 cdrom LINUX mount t 1509660 dev scdO cdrom See your specific UNIX mount options Error message during start of Upsagent Communication lost a Is the UPS cable plugged in the correct way Plug side of the SUB D9 to the UPS Do you use any adapters If so check the contact of the cable the pin layout and their correct correspondence to your UPS user manual interface description b Has the port of the Un
93. ween calls min a 7 Accept incoming calls UPSMON User Manual Advanced UPSMON Configuration e 47 Parameter name Parameter description Enable or disable modem support When disabled the UPSMON cannot call teleservice control Enable modem support service Connection serial port The serial port where the modem is connected Primary Secondary telephone The telephone numbers of the teleservice control centre these are the number where the modem number will call in case of an emergency Number of repeat calls The number of times the system will attempt to call in the event of a busy line or no answer Delay between calls The minutes of delay between each call attempt r Accepts incoming calls from a teleservice control centre This can be turned off for security Accept incoming calls ie Terminal upsetuo 80x24 CoA Aodes conf iguraotion gt 1 Enable GOA moea support t nection serial port 3 W5 Centre member 4 CSA modes type 51 Exit Parameter name Parameter description Enable GSM modem support Enable or disable GSM modem support When disabled the UPSMON cannot send SMS Connection serial port The serial port name where the modem is connected SMS Centre number Contact your SIM card provider to obtain this number GSM modem type The supported modems are Siemens and Falcon 48 e Advanced UPSMON Configuration UPSMON User Manual 2 4 Scheduler Configuration of
94. xrate baud You can find further information concerning the parameters in aiocomx help and on the CD in the Drivers directory 4 Troubleshooting Windows Problem Upsagent does not start UPS Communications lost Answer This error means that you are using a device name which does not exist Try another device and check the NT serial connection settings Problem UPS shutdown contact closure when NT is booting Answer a This problem occurs because of a high signal on the com port when Windows NT searches for serial mouse hardware Change the entry in BOOT INI multi 0 disk 0 rdisk 0 partition 2 WINNT Windows NT Workstation Version 4 0 noserialmice comx where x represents the COM port where NT should not search for a mouse because the UPS is connected here Exception any none MS mouse drivers have to be disabled via the device manager 5 Troubleshooting UNIX Problem When reading the disk an error message appears can not open file can not read disk Answer a You have entered the name of your disk drive wrong Please check which driver is installed for the disk in the directory dev The disk should read as rawdisk on most systems b Is the disk being read with the correct command With the UPSMON software the disk is formatted in the TAR format C Is the disk or the disk drive defective Please try the disk on another Unix system or maybe ask your dealer for a replacement disk d Is the disk d