Home

EURO 46 User Manual - Castle Care-Tech

image

Contents

1. EURO User Manual Using an External Proximity Reader Setting your EURO panel with the External Proximity Reader Present a valid tag to the reader and then remove it The GREEN LED will come on Present the same tag to the reader and then remove it The exit time will start on the control panel The RED LED may be programmed to illuminate under certain actions for example when the system is set Unsetting your EURO panel with the External Proximity Reader Present a valid tag to the reader and then remove it The GREEN LED or RED LED if programmed will be displayed Present the same tag to the reader and then remove it The exit time will start on the control panel The RED LED will extinguish and after 25 seconds the GREEN LED will extinguish Page 9 EURO User Manual Intelligent Set This function If you wish to set your EURO panel and needs enabling stay in the building e g set the alarm by your installing at night the EURO s intelligent company operating system will realise which level of security you require and will set only part of the system You will NOT need to press a Push to Set button if you set only part of a system If intelligent set is not installed on your system you may part set the system as described on pages 11 12 To Part Set EURO go to the keypad and enter your PIN code or present your Tag The appropriate A B C D keys will illuminate Exit tone will start
2. Leave the protected area and retire to the un protected area e g upstairs EURO will detect you have gone upstairs and set the appropriate areas accordingly After a pre set time the exit tone will cease Your EURO panel is now Part Set Page 10 EURO User Manual Codes with Flexi Set Sometimes your security needs will be a little more complex and you will need to use the AB C D keys Your installer can also give names to all four of the A B C D areas so that you can easily identify them For example A Reception or All Set B Warehouse Bedtime Set C Office Cat in Lounge D Storeroom Dog in Study In addition names can be given to the whole system ALL AREAS These will be displayed when setting the system Note The Euro 46 has six available areas labelled as ABCDO1 Page 11 EURO User Manual Codes with Flexi Set For greater flexibility in setting parts of your system you can make a choice at the keypad Key in your PIN code or present your Tag If you do not wish to set all the areas assigned to your PIN code tag simply select the areas you wish to Set by pressing the relevant ABCD key s To change your mind press the relevant A B C D key s again Press the Yes key to accept Setting areas will now be displayed with the corresponding area keys being lit EURO will now set the selected areas Page 12 EURO User Manual Codes with Flexi Set When
3. NO systems installed to European Grade 2 requirements must have 10 000 code differs systems installed to European Grade 3 requirements have must 100 000 code differs Tags have 2 8 thousand billion differs 16 There are no disallowed codes Page 27 EURO User Manual Changing or Adding PIN Codes or Tags Using the numeric keys you can enter a user name similar to typing a text message on a mobile phone Use 0 key for space The A B C D keys on the keypad are used as follows A capital letters B moves cursor left C Clears Character creates a space D Cursor moves right e g to write John simply press the 5 key once D move cursor right 6 key three times The predictive text library selects John press YES to accept If the word you require is not in the predictive text database key in the letter using the individual keys and press YES When you have finished and wish to go to the next menu press NO Page 28 EURO User Manual Review History Log Press YES Press NO to move to the next menu Press YES To advance through the logs Press D For added information Press C To move backward to previous events Press B To stop review Press NO To move to the next menu press NO again Note If an access control facility is in use a Separate d
4. Page 33 EURO User Manual Dial Out Menu Your alarm system may be configured so that you can control the system via a PC If you wish to continue Press YES Press NO to move to the next menu Use the D key to select the required PC from the list 1 4 and Press Yes Use the D key to select the operation you require Data to PC View the system history on your PC where it can be searched and printed Diagnostics Sends electrical and diagnostic data to your PC where it can be printed if required Press YES Page 34 EURO User Manual Allow Engineer Menu When your alarm installation engineer comes to your premises for a maintenance visit or to correct a fault after an alarm he will require access to the programming of the system Press YES Use B amp D keys to make your choice Press YES After the engineer has finished on site you may return this setting to NO Testing your Sounders Press YES Press NO to move to the next Menu Press YES Siren will sound Strobe will flash Press NO to move to next menu Page 35 EURO User Manual Block Remote Set Your alarm system may be configured so that your alarm installation company or company manager can set or unset the system remotely via PC Should you wish to block this access you can do so through this menu Press YES Make your c
5. Pes aN a a Fault nset Tamper The Alert LED will flash if there is information available to you Enter your code to see the information After a code has been entered one of the following LEDs will light Alarm tamper or fault The relevant detail of the problem will be Shown on the display To clear the display press the Yes key or the display will clear automatically after 3 minutes The Alarm LED will flash after code entry if an alarm occurs The Tamper LED will flash after code entry if the wiring or equipment is tampered with The Fault LED will light after code entry to indicate if a technical fault occurs The Unset LED will light for 5 seconds if the panel is completely Unset steady or if some areas remain Set flashing It will also illuminate during the setting procedure turning off once set Page 4 EURO User Manual Security Checks Before you set your system You must ensure all doors and windows are securely closed and any pets or people are excluded from areas protected by movement sensors Close Doors amp Windows Exclude Pets and People Page 5 EURO User Manual Leaving the Building If you are leaving the building go to your keypad and key in your PIN code or present your tag The Exit Tone Starts The appropriate area ABCD keys will illuminate If flexi set is enabled you will be able to choose which areas you set see p
6. EURO is already set and you wish to unset Key in your PIN code or present your tag If entry timer has started All areas for which the tag or PIN code is valid will be unset Any areas set for which the code is not valid will remain set e g if A and B are set If a tag valid for area A only is presented then area A will be unset leaving B set If a tag valid for areas A B is presented both A amp B will be unset If a tag valid for areas A B C is presented it will unset A amp B leaving C unset If entry timer is not running You will be asked if you wish to set any areas currently not set Press YES to do so or press NO to unset the system If there are NO areas set for which the code is valid the system will SET as described on page 12 Note Your alarm installing company may have programmed keypads to set and unset certain areas only Page 13 This function needs enabling by your installing company EURO User Manual Flexi UnSet If your codes have been set up with Flexi Unset enabled you will always have a choice of what areas you would like to set or unset regardless of whether the entry timer is running or not providing you have a code valid for the relevant areas This function can only be enabled by your alarm installing company and will not be permitted if your system is designed to comply with clause 6 4 5 of DD243 2004 Ask your installer for f
7. T 50131 3 2003 EN50131 1 PD6662 Security Grade 3 Environmental Class 2 EURO 46 User Manual For use with the EURO 46 www castle caretech com CASTLE RINS1339 1 EURO User Manual Contents Introduction 1 5 Using EURO Panel with Code or Tag 6 8 Using Tags with External Prox Readers 9 Intelligent Setting 10 Setting Individual Areas 11 14 Omitting Inputs 15 16 Silencing the Alarm 17 Resetting the Alarm 18 Chime Facility 19 Keypad Hold Up Personal Attack 20 Manager Menu 21 Changing Date amp Time 22 Omitting 24 hr Inputs 23 Change Add Codes or Tags 24 28 Review History Log 29 SMS Phonebook 30 Walk Testing Detectors 31 SMS Messaging System 32 33 Dial Out Menu 34 Testing your Sounder 35 Allow Engineer Menu 35 Block Remote Set 36 Troubleshooting 38 39 Service amp Codeholder Records 40 41 Disclaimer 42 Note the specification of EURO panels may vary between models and some facilities in the manual may not be available Check with your installer for full details This equipment may be used in systems installed to a lower grade which will be agreed with your installation company There are no user serviceable parts contained in this product This manual is for use with panels fitted with version 7 software Castle Care Tech 2009 RINS1339 Issue 1 Page 1 Note For your security the keypad becomes disabled for 90 seconds after 30 incorrect key presses It will subsequently be di
8. The tone will cease after about 10 seconds Press the NO key The system will remain unset so you can resolve the problem For example you may have left a door open if so close the door You can now recommence the setting procedure Page 38 EURO User Manual Troubleshooting Problems when leaving the Building If when you have closed the final exit door and pushed the Push to Set button f fitted the exit tone continues to sound an interrupted tone beep beep beep You have probably left a protected door on the exit route open Return to the keypad and note the message on the display Stop the setting procedure with your PIN code or Tag Close the open door Now commence the setting procedure again see page 6 Page 39 EURO User Manual Service Information We are sure that you will be delighted with your Euro Alarm installation For your personal reference here is a record of the relevant service information Service Company Date of Installation pay Month Year Site Reference 24hr Service Number Tel Keyholders Name Tel Name Tel Panel Type Software Version Installed to Grade Environmental Class 2 External set unset readers and access control readers meet the requirements of environmental class 4 Page 40 EURO User Manual User Codes Warning This information should be removed from the manual and stored in a secure location Photo
9. age 12 Leave by agreed Exit Route Close and Lock the Final Exit Door If your exit is timed Finally press the Push to Set you will see the above button if fitted that is mounted screen i externally by the final exit door If you use a Push to Set button or final door set you will see The Exit Tone will cease the screen below EURO is now SET Page 6 This function needs enabling by your installing company EURO User Manual Simple Setting It is also possible to set the EURO without using your PIN code or Tag When your system is unset press the YES key and then select the area you wish to set For example to set area C Press YES then Press C The exit procedure will start beep beep beep EURO Is now Set Please note that when using the simple set facility the user who initiated the set cannot be logged Page 7 EURO User Manual Entering the Building To enter the building you must use the agreed entry route and go straight to the keypad The Entry Tone will be sounding beep beep beep Key in your PIN code or present your tag The Entry Tone will cease To indicate that the system has unset the unset LED will illuminate for five seconds EURO is now UNSET Page 8
10. ber whose PIN code Tag you wish to add or change Press YES Key in the new 4 5 or 6 digit PIN code you require or present the new Tag To delete a code or Tag press C Press YES EURO will not allow you to programme in codes that are already in use by the system Standard users can only edit their own code Managers can only programme new users with access to the same areas as he she has access Page 25 EURO User Manual Changing or Adding PIN Codes or Tags Choose the level of authority the user is allowed User cannot access Manager Menu Manager can use Manager Menu Use B amp D keys to make your choice Press YES Using the A B C D keys choose the areas you wish to be controlled by the user Managers may not give other users access to areas he himself cannot access Press YES Choose the limits you wish to place on the user s actions Set amp Unset Set only Unset only choose None if the Tag is only for Access or Ward control Use B amp D keys to make your choice Press YES Page 26 EURO User Manual Changing or Adding PIN Codes or Tags Flexi Set gives you the opportunity to choose the areas you require to set when you use your PIN code or Tag If you do not choose Flexi Set your Code Tag will simply set the areas assigned without offering you the opportunity to choose For simplicity of use choose
11. copy this page if you have more users Access 00 John Manager ABCD Set unset NO 128 To ee ee ee ee Page 41 EURO User Manual Disclaimer EURO includes the facility to send electronic signals to an Alarm Receiving Centre ARC and also to send SMS text messages to mobile telephones Alarm etc signals may be transmitted via a PSTN link using a variety of formats to suitable receiving equipment located at the premises of an independently operated Alarm Receiving Centre Provision is also made for the use of third party device to transmit signals to an Alarm Receiving Centre by means of the PSTN GSM IP or other network The SMS facility uses a PSTN connection to a special SMS Centre SMSC where the information is transferred to the GSM network for delivery to the client s designated mobile telephone s The SMSC services are provided by GSM network operators or other reputable companies whose operation is outside of the control or influence of Castle Care Tech Ltd Castle Control Panels have an embedded premium rate telephone number that is used to contact a Castle host computer prior to commissioning in order to download the SMSC details and appropriate call routing authorisation The control panel will continue to contact this CHC at regular intervals to verify the operation and update and confirm the routing information and authorisation as appropriate The charge for this service is raised by the use of the
12. eady to use This 6 digit code is also displayed in the user menu see page 36 Page 18 EURO User Manual The Chime Facility The C key can be used to select the chime facility while the system is Unset For example you may wish to be alerted if someone enters through a particular door during the day Simply press the C key The display will show a C Now if the door opens you will be alerted by the chime tone To cancel the Chime function simply press C again Note This is only operative on detectors programmed for this purpose If multiple detectors are programmed to permit this the sounder will not distinguish between them This function needs enabling by your installing company Page 19 This function needs enabling by your installing company EURO User Manual Keypad Hold Up If you need to summon personal assistance in an emergency EURO allows you to do so Simply press the 1 and 7 keys at the same time To reset Enter you PIN code or present your Tag This facility is only available if it has been enabled by your alarm installer 2 Key PA and any duress codes programmed on the system by your engineer are not permitted to send a signal to the Alarm Receiving Centre under police regulations in England Wales or Northern Ireland Page 20 EURO User Manual Manager Menu The manager menu is accessed by p
13. edicated access control event log is recorded Page 29 EURO User Manual SMS Phone Book Press YES Press NO to move to the next Menu Use the D key to scroll to which SMS telephone number you wish to change 1 4 Press YES Using the numeric keys type in the new telephone number do not leave any spaces You can move the cursor back with the B key and forward with the D key Use the C key to delete a character Press YES Select the next mobile telephone number you wish to change or Press NO to move to the next menu Page 30 EURO User Manual Testing your System Press YES Press NO to move to the next Menu Choose the area s you wish to test by pressing the appropriate ABCD keys Press YES All detectors waiting to be tested will scroll in the display Walk around the building and activate all of the detectors The system will chime each time a detector responds When all detectors have been activated and are working the display will show Walk Test Completed To move to the next menu press No Page 31 This function needs enabling by your installing company EURO User Manual Test CHC Communications Your system may have been configured to send messages to a mobile telephone If so the system will call the appropriate messaging bureau and forward the message to you
14. hoice with the B and D keys Block UDL If you wish that your alarm company can only dial into your system with their PC whilst their engineer is on site this can be set up through the Block UDL menu Page 36 EURO User Manual Menu Exit To exit from Manager Menu and return to normal mode Press YES If you wish to select any of the Manager Menu items again press the NO key until your choice is displayed see page 21 Manager User Menu Options Operators holding Euro Manager codes have access to the following programming options Set Date amp Time page 22 Change User Codes page 24 Change Mobile Telephone Numbers page 30 Allow Engineer Access page 35 Inhibit omit Zones from the system page 22 Allow Remote Set page 36 To enter manager menu press D and enter your Manager PIN code or tag Every user has access to the following programming options Change his her own code page 24 Allow Remote Set page 36 Allow Engineer Access page 35 To enter your user menu press D and enter your user PIN code or tag Page 37 EURO User Manual Troubleshooting Help with Setting your System If when you key in your PIN code or present your Tag a warning tone sounds and the fault LED comes on the keypad display will show the nature of the problem An appropriate A B C D key will flash to indicate within which area the problem exists
15. ng in the design and manufacture of high quality security control equipment
16. premium rate telephone number Please check with your installer for exact charges In order for the SMS service to work you must not have 09 or 07 numbers disabled on the telephone line Whilst we will use our best endeavours to resolve any issues relating to these uses of equipment manufactured by us Castle Care Tech are in no way responsible for the operation of the PSTN or other transmission media the Alarm Receiving Centre ARC or the SMSC or for the end to end security and delivery of information and messages involved EURO is designed to automatically disable certain functionality The factory default settings are as shown below 1 confirmed alarm 1 confirmed alarm Keypad After 30 keypresses without entering a valid code keys are disabled for 90 seconds After reinstatement this will be repeated after each 7 keypresses until a valid code is entered Tag Reader or Tag at After 6 presentations of an invalid tag the reader a keypad will be disabled for 90 seconds After reinstatement this will be repeated for each invalid tag until a valid tag is used This figure is programmable by the installing company Page 42 Descriptions Page 43 Page 44 Website www castle caretech com Castle Care Tech Ltd reserves the right to adjust specifications of this system at any time and without notice in the interests of product improvement Castle Care Tech Ltd is an independent British company specialisi
17. r any other inputs that need to be omitted After 10 seconds EURO will begin to set These inputs will be omitted for this one period only Page 16 EURO User Manual Silencing Alarms If an alarm tone sounds the alert LED will flash Just key in your PIN code or Present your tag The Alarm will stop sounding The display will indicate the why the alarm has activated Press the YES Key EURO will advise you on any action that is needed If the Alert LED indication remains lit there is additional information available Enter your PIN or present your tag to view Page 17 EURO User Manual Engineer Reset Corema y When an alarm has been cancelled and wees the Police have been notified by the Alarm Receiving Centre ARC you will see the screen shown left when you try to use the system It is usually necessary for an engineer from your installation company to check the installation and reset the system for further use But if you have caused the alarm in error your Alarm Receiving Centre or Alarm Installation Company may permit you to reset the system without an engineer present You will be required to quote a 6 digit code by telephone advise them that the system is a Castle Euro ONE You will then be given a special code which will reset the system for that one occasion only Enter the anti code given to you by your installation company You alarm in now restored and r
18. r mobile telephone whenever an event occurs that is important to you Message calls are charged at the normal network rate current at the time of the call The fee for routine checking is collected automatically via a premium rate number when the EURO panel makes its regular authorisation and routing call to the Castle Host Computer CHC Should this call fail the display will show CHC Test Fail until the next time that the call is made successfully see next page for making test calls to the CHC This acts as a reminder that SMS Message signalling may not be operational but will not interfere with this or any other aspect of the alarm system If you wish to change the information sent to your mobile telephone please contact your alarm system installation company Please note that all CHC calls are 50p per call Page 32 EURO User Manual Test CHC Communications It is recommended that this test Is only undertaken under the supervision of your alarm installation engineer Press NO to move to the next menu Press YES to make the test under the direction of an alarm engineer the test call will be via a premium rate number If your alarm panel is connected to an internal telephone network PABX system which requires a 9 for an outside line press YES otherwise press NO Once test is complete press YES Please note that all CHC calls are 50p per call
19. ressing D and then keying in your Manager PIN code You then have a choice of Set Date amp Time see page 22 Omit Inputs see page 23 Change Code s see page 24 Review Logs see page 29 Phone Book see page 30 Walk Test see page 31 Siren Test see page 35 Test CHC Communications see page 32 Dial Out Menu see page 33 Allow Engineer Menu see page 35 Block Remote Set see page 36 Block UDL see page 36 Exit Manager Menu see page 37 These features can also be accessed with a standard user code Pressing the NO key will take you from one Menu to the next as well as Escaping from within a menu Pressing the YES key will take you into a menu as well as Accepting a choice within a menu It is recommended that the system is fully unset when using Manager Menu functions Page 21 EURO User Manual Set Date and Time Press NO to move to next menu Press YES Press NO to move to the next menu Enter Year eg 06 2006 Press YES Enter Month Press YES Enter Day Press YES Enter Hours 24 hour clock Press YES Enter Minutes Press YES To go to the next menu press NO again Press YES Press NO to move to the next Menu Page 22 EURO User Manual Omit Inputs Some of your doors may rarely be used e g fire doors and your system ma
20. sabled again after 7 further incorrect key presses Once a correct code has been registered the keypad is returned to normal operation Please note that Keypad design may differ from that shown EURO User Manual The Euro Keypad Using your EURO Alarm System just couldn t be easier This is the Keypad from where you control your Alarm System The LCD display guides you through user menus and gives you any important messages regarding the status of the system The 10 digit numeric keypad is where you use your PIN code The A B C D keys allow you to choose which level of security you wish to apply when you leave the building or to part set the system Page 2 EURO User Manual Using Proximity Tags Your EURO system may have been enabled for use with proximity tokens or Tags If you have Tag Readers installed then simply hold your Tag against the Tag logo When using the keypads hold your Tag to the area shown left When your Tag has been accepted there will be an acknowledgement beep You can use your Tag in place of a pin code for all operations of the alarm system i e setting unsetting and entering the Manager and User Menus The tag contains NO batteries and is completely maintenance free Page 3 EURO User Manual Warning Indications All setting points Keypads or Tag Readers have LEDs to clearly indicate what is happening a
21. urther details Page 14 This function needs enabling by your installing company EURO User Manual Deliberately omitting an Input when leaving the Building In a domestic setting you may wish to ignore a window you have deliberately left open in the summer time There may be another fault on the system which you want to ignore when you set the system Enter your PIN code or present your tag The display will ask if you wish to set with the fault To omit the fault Press YES or NO if you do not wish to omit The system will then set as normal The fault will be omitted for this one arming period only NOTE Only doors or windows already open can be omitted in this way The system may be programmed to be able to set with certain types of fault e g mains fail but not others e g telephone line fault Page 15 This function needs enabling by your installing company EURO User Manual Deliberately omitting an Input when leaving the Building At some time you may wish to isolate a detector if a room is occupied Enter your PIN code or tag While the exit tone is sounding press the YES key When the OMIT INPUT menu is displayed Key in the number of the input you wish to omit and press YES Always use a leading zero eg 02 is input 2 On larger systems 002 is input 2 If it has been accepted it will be displayed on the screen Repeat fo
22. y be designed such that if they are opened your panel will generate an alarm even if the panel is unset If you need to open these doors you can omit them from the system as shown below Only inputs of tamper and day alarm type can be omitted this way as set up by your alarm installing company Enter the input number you wish to omit Press YES To reinstate inputs simply key in the number again Press No when your selection is complete Inputs omitted while UNSET will NOT be omitted when you SET the system See page 16 for more information on omitting inputs Page 23 EURO User Manual Changing or Adding PIN Codes or Tags A record should be kept as shown on Page 41 Press YES Press NO to move to the next Menu Press YES Press NO to program the Master Manager Code Turn to the next page to continue to program user codes Press YES Press NO to move to the next menu The Master Manager Code can only be changed by the Master Manager Turn to the next page to continue to program the Master Manager Code Page 24 Note European Grade 3 alarm systems will only accept 5 or 6 digit codes or tags EURO User Manual Changing or Adding PIN Codes or Tags EURO identifies each user by a different User Number Eg John would be user O1 Jane would be user O2 etc Now key in the User Num

Download Pdf Manuals