USER'S MANUAL

image

Contents

1. 1280 7201 00 KS 1280UK R1 2009 10 22 5 49 PM Page 1 F Kidde USER S MANUAL A EN 14604 2005 LICENSE NO KM 524754 CE 0086 CPD 535595 Model FADC230 lonisation PLEASE READ AND SAVE INSTALLER Please leave this manual with the product SMOKE ALARM DESCRIPTION Model FADC230 lonisation 230V AC smoke alarm with Easy Access Battery Door and False Alarm Control SMOKE ALARM FEATURES Interconnects with up to 24 alarms Unique power connector prevents interconnection with incompatible smoke alarms or security systems Tamper resist bracket quickly snaps into place and serves as a safeguard against tampering Multi purpose green and red LEDs indicate that the smoke alarm is receiving AC power working under normal operation in alarm or under False Alarm Control Loud alarm horn 85 decibels at 3 metres 10 feet sounds to alert you of an emergency Test button checks smoke alarm operation Feature False Alarm Control which when activated quiets unwanted alarms for up to 15 minutes Features an easy acces front loading battery compartment Battery door can not be closed if battery is not properly installed Model FADC230 features a latching LED which blinks the initiating alarm s red LED 3 times each minute until manually reset Model FADC230 has a ramp up test horn feature which emits 2 reduced vol ume beeps before reaching the full 85db level during testing IMPORTANT SAFETY INFORMATION PLEASE RE
2. and you may also have other legal rights which vary from state to state Return units freight prepaid to your local reseller For information on your local reseller in the U K and Republic of Ireland contact KIDDE SAFETY EUROPE LIMITED Mathisen Way Colnbrook Berkshire SL3 OHB United Kingdom Tel 44 0 1753 685148 www smoke alarms co uk Kidde strongly recommends that both ionization and photoelectric smoke alarms be installed to insure maximum detection of the various types of fires that can occur within the home lonization sensing alarms may detect invis ible fire particles associated with fast flaming fires sooner than photoelec tric alarms Photoelectric sensing alarms may detect visible fire particles associated with slow smoldering fires sooner than ionization alarms 1280 7201 00
3. and hold test button for at least three seconds after the first unit sounds Hire an electrician to ensure smoke alarms are properly connected WARRANTY Kidde warrants to the original consumer purchaser each new smoke alarm to be free from defects in material and workmanship under normal use and serv ice for a period of six 6 years in the United Kingdom and Republic of Ireland from date of purchase Kidde agrees to repair or replace at its option any defective smoke alarm provided that it is returned with postage prepaid and with proof of purchase date to Kidde This warranty does not cover damage resulting from accident misuse or abuse or lack of reasonable care of the product This warranty is in lieu of all other express warranties obligations or liabilities THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FIT NESS FOR A PARTICULAR PURPOSE ARE LIMITED TO A PERIOD OF SIX 6 YEARS FROM PURCHASE DATE Some states do not allow limitations on how long an implied warranty lasts so the above limitations may not apply to you IN NO CASE SHALL KIDDE BE LIABLE FOR ANY INCI DENTAL OR CONSEQUENTIAL DAMAGES FOR BREACH OF THIS OR ANY OTHER WARRANTY EXPRESS OR IMPLIED WHATSOEVER EVEN IF THE LOSS OR DAMAGE IS CAUSED BY ITS NEGLIGENCE OR FAULT Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you This warranty gives you specific legal rights
4. AD AND SAVE THESE INSTRUCTIONS A W ARNING e AC smoke alarms require constant 230V AC 50Hz power to operate properly Mains powered smoke alarms WILL NOT work if AC power is not connected or has failed or been interrupted for any reason This alarm requires a working 9 volt battery to operate properly in the event of a power failure DO NOT use any other kind of battery except as specified in this manual DO NOT connect this smoke alarm to any other type of smoke alarm or auxiliary device except those listed in this manual DO NOT remove or disconnect battery or turn off AC power to quiet unwanted alarms This will remove your protection Open windows or fan the air around smoke alam to silence it This alarm features a False Alarm Control button which when activat ed will quiet unwanted alarms for up to 15 minutes The Push to Test button accurately tests all smoke alarm functions DO NOT use any other test method Test smoke alarm weekly to ensure proper operation This smoke alarm should be installed only by a qualified electrician This smoke alarm is designed to be used inside a single family household only In multi family buildings each individual living unit should have its own smoke alarms Do not install in non residential buildings or places which house many peo ple like hotels motels dormitories hospitals nursing homes or group homes of any kind This smoke alarm is not a substitute for a complete alarm system Install a smo
5. Control Press and release the test button during an unwanted alarm The alarm should stop within ten seconds This means the smoke alarm is in False Alarm Control If the smoke alarm does not go into False Alarm Control and continues to sound its loud alarm horn or if it initially goes into False Alarm Control then resounds the alarm the smoke is too heavy and could be a dangerous situation take emer gency action TESTING THE SMOKE ALARM A WARNING Test each smoke alarm to be sure it is installed correctly and operating properly Test all smoke alarms in an interconnected system after installation The Push to Test button accurately tests all functions DO NOT use an open flame to test this smoke alarm You may ignite and damage the smoke alarm or your home Test smoke alarms weekly and upon returning from holiday or when no one has been in the household for several days Stand at arm s length from the smoke alarm when testing The alarm horn is loud to alert you to an emergency and can be harmful to hearing Test all smoke alarms weekly by doing the following 1 Check Push to Test button A constant green light indicates the smoke alarm is receiving 230V AC 50Hz power A red flashing LED about once a minute veri fies operation The red flashing LED also verifies that a working battery is pres ent 2 Firmly depress the Push to Test button for at least five 5 seconds The smoke alarm will sound a loud beep ab
6. alarm is not operating properly see Troubleshooting If necessary and if still under guarantee return smoke alarm to Kidde Pack it in a well padded carton and send postage prepaid to Kidde address at the end of this manual If the smoke alarm is no longer under guarantee have a licensed electrician replace the smoke alarm immediately with a comparable Firex brand smoke alarm PRACTICE FIRE SAFETY If the smoke alarm sounds its alarm horn and you have not pushed the test button it is warning of a dangerous situation Your immediate response is nec essary To prepare for such occurrences develop family escape plans discuss them with ALL household members and practice them regularly Expose everyone to the sound of a smoke alarm and explain what the sound means Determine TWO exits from each room and an escape route to the outside from each exit Teach all household members to touch the door and use an alternate exit if the door is hot INSTRUCT THEM NOT TO OPEN THE DOOR IF THE DOOR IS HOT Teach household members to crawl along the floor to stay below danger ous smoke fumes and gases Determine a safe meeting place for all members outside the building WHAT TO DO IN CASE OF A FIRE 1 Don t panic stay calm 2 Leave the building as quickly as possible Touch doors to feel if they are hot before opening them Use an alternate exit if necessary Crawl along the floor and DO NOT stop to collect anythin
7. d member is hearing impaired install special smoke alarms with lights or vibrating devices to alert occupants e Smoke alarms can only sound their alarms when they detect smoke Smoke alarms detect combustion particles in the air They do not sense heat flame or gas This smoke alarm is designed to give audible warning of a devel oping fire However many fires are fast burning explosive or intentional Others are caused by carelessness or safety hazards Smoke may not reach the smoke alarm QUICKLY ENOUGH to ensure safe escape e Smoke alarms have limitations This smoke alarm is not fool proof and is not warranted to protect lives or property from fire Smoke alarms are not a substitute for insurance Homeowners and renters should insure their lives and property In addition it is possible for the smoke alarm to fail at any time For this reason you must test the smoke alarm weekly and replace every 10 years SMOKE ALARM PLACEMENT It is recommended to achieve complete coverage protection by installing a smoke alarm in every room of your home At a minimum smoke alarms shall be installed outside of each separate sleeping area in the immediate vicinity of the bedrooms and on each additional storey of the family living unit including basements and excluding crawl spaces and unfinished attics Any home requires a minimum of two smoke alarms FOR BEST PROTECTION IT IS RECOMMENDED THAT YOU INSTALL A SMOKE ALARM IN EVERY ROOM In additi
8. e alarm to live red or brown mains power wire 3 5 If interconnection is desired connect orange wire from connector to intercon nect wire between smoke alarms See section Interconnecting Smoke Alarms NOTE If this will be a single station smoke alarm cover orange wire with electrical tape and tuck into ceiling wall or pattress ELECTRICAL BOX OR PATTRESS T CEILING LINE E LEP INTERLINK LO NEUTRAL BLUE BROWN ORANG MODEL FADC230 Lift open battery pocket door 7 Connect new 9 volt battery to battery connector inside battery pocket BE SURE BATTERY IS SECURELY CONNECTED Smoke alarm may beep briefly when bat tery is installed 8 Close battery pocket door snapping it into place 9 Push button and hold button on front cover of smoke alarm for three 3 sec onds Smoke alarm should sound its alarm horn if battery is fitted correctly 10 Attach connector plug to pins on back of smoke alarm Plug will only fit one way and will snap into place 11 Gently tug connector to be sure it is attached securely 12 Position smoke alarm to mounting plate so that keyslot on side of smoke alarm is to left of tab on mounting plate Turn clockwise to lock into place 13 Remove arrow tab and close battery door Smoke alarm may beep briefly as door is closed 14 Test smoke alarm See TESTING THE SMOKE ALARM INTERCONNECTING SMOKE ALARMS Use 1 5mm m
9. e smoke alarm is receiving AC power Use only the following batteries as replacements in this smoke alarm Eveready 216 522 1222 Duracell MN 1604 or Ultralife U9VL J Replace only with the same or equivalent battery type recommended by the manu facturer Discard used batteries safely according to manufacturer s instructions TEST THE ALARM FOR CORRECT OPERATION USING THE TEST BUTTON WHENEVER THE BATTERY IS REPLACED A WARNING DO NOT USE ANY OTHER TYPE OF BATTERY EXCEPT AS SPECIFIED IN THIS MANUAL DO NOT USE RECHARGEABLE BATTERIES 1 Turn off power to smoke alarm at main service panel 2 Slide battery door open as shown in the illustration p Remove drained battery from compartment and discard Install a fresh 9 volt battery Slide battery door closed Turn on power and test smoke alarm using Push to Test button CLEANING Clean the smoke alarm at least once a month to remove dust dirt or debris Always turn off power to smoke alarm before cleaning Using the soft brush or wand attachment to a vacuum cleaner vacuum all sides and cover of smoke alarm Be sure all the vents are free of debris OP es O f necessary turn off power and use a damp cloth to clean smoke alarm cover IMPORTANT Do not attempt to remove the cover or clean inside the smoke alarm THIS WILL VOID YOUR GUARANTEE REPAIR A CAUTION Do not attempt to repair this smoke alarm Doing so will void your guarantee If smoke
10. g 3 Meet at a pre arranged meeting place outside the building 4 Call the fire brigade from OUTSIDE the building 5 DO NOT GO BACK INSIDE A BURNING BUILDING Wait for the fire brigade to arrive These guidelines will assist you in the event of a fire However to reduce the chance that fires will start practice fire safety rules and prevent hazardous situations TROUBLESHOOTING DANGER Always turn off power at main fuse box or consumer unit before taking trouble shooting action A WARNING DO NOT disconnect battery or mains power to quiet an unwanted alarm This will remove your protection Fan the air or open a window to remove smoke or dust You may also use the false alarm control feature you may also use the False Alarm Control feature to quiet unwanted alarms Smoke alarm does not sound when tested NOTE Push test but ton for at least five 5 seconds while testing Smoke alarm sounds unwanted alarms when residents are cooking taking showers etc Interconnected smoke alarms do not sound when system is tested Check that AC power is turned on Green LED should be illuminated Turn off power Remove smoke alarm from mounting plate and a check that connector plug is securely attached check that battery is properly attached to connector Clean smoke alarm Hire an electrician to move smoke alarm to a new location See SMOKE ALARM PLACEMENT Press
11. inimum solid or stranded wire with a rating of 230V When inter connecting maximum wire length between any two is 450 m for 1 5mm or 1200 m for 2 5mm 20 OHMS loop resistance This smoke alarm may be interconnected with as many as 24 other Models Connect smoke alarms to a single AC branch circuit If local codes do not per mit be sure the neutral wire is common to both phases Wiring must conform to IEE Regulations for electrical installation RED AND GREEN LED INDICATORS This smoke alarm features red and green LED indicators that can be seen through the Push to Test button or the LED lens above the test button The LEDs indicate the following GREEN LED ON AC power is present OFF AC power is not present RED LED Blinks once a minute Blinks once a second indicating normal operation smoke alarm senses smoke and simultane ously sounds an audible alarm Blinks once every 10 seconds smoke alarm is quieting an unwanted alarm Interconnected system only OFF another smoke alarm in the network has sensed smoke and is signalling this alarm RED blinks 3 times indicates this unit initiated an every minute alarm in an inteconnected system press the test button to reset indicates weak or improperly connected battery RED blinks 4 times every minute preceded by an audible chirp 1280 7201 00 KS 1280UK R1 2009 10 22 5 50 PM Page 2 FALSE ALARM CONTROL To use the False Alarm
12. ke alarm in every room and on every level of the home Smoke may not reach the smoke alarm for many reasons For example if a fire starts in a remote part of the home on another level in a chimney wall roof or on the other side of a closed door smoke may not reach the smoke alarm in time to alert household members A smoke alarm will not promptly detect a fire EXCEPT in the area or room in which it is installed e Interconnected smoke alarms installed in every room and on every level of the household offers maximum protection We recommend interconnecting smoke alarms so that when one smoke alarm senses smoke and sounds its alarm all others will sound as well Do not interconnect smoke alarms from one individual family living unit to another Do not connect this smoke alarm to any other type of alarm or auxiliary device Smoke alarms may not alert every household member every time The alarm horn is loud in order to alert individuals of a potential danger However there may be limiting circumstances where a household member may not hear the alarm i e outdoor or indoor noise sound sleepers drug or alcohol usage the hearing impaired etc If you suspect that this smoke alarm may not alert a household member install and maintain specialty smoke alarms Household members must hear the alarm s warning sound and quickly respond to it to reduce the risk of damage injury or death that may result from fire If a house hol
13. ome no matter how small the home Any size TOP OF DETECTOR home requires fitting a minimum of two smoke alarms ACCEPTABLE HERE NEVER HERE ACCEPTABLE HERE sinen WALL Install a smoke alarm in each room that is divided by a partial wall either coming down from the ceiling at least 60 cm 24 inches or coming up from the floor Install smoke alarms on peaked cathedral or gabled ceilings 1 m from the highest point measured hori zontally Install a smoke alarm in lived in attics or attics which s SOFFIT 600m por am STUB WALL house electrical equipment like furnaces air condi tioners or heaters DO NOT install smoke alarms ii Near appliances or areas where normal com bustion regularly occurs kitchens near boil ers hot water heaters Use specialized smoke alarms with unwanted alarm control for these areas PEAKED CEILING Fj In areas with high humidity like bathrooms or areas near dishwashers or washing machines Install at least 3 metres away from these areas Near air returns or heating and cooling supply vents The air could blow smoke away from the detector interrupting its alarm In rooms where temperatures may fall below 5 C 41 F or rise above 45 C 113 F In extremely dusty dirty or insect infested areas Loose particles interfere with smoke alarm operation Do not site
14. on it is recommended that all smoke alarms be interconnected Typical Efficiency Home Apartment Install a smoke alarm on the ceiling or wall stereo closest to the sleeping area Install a smoke alarm with False Alarm Control in the kitchen living area Typical Single Storey Home Install a smoke alarm on the ceiling or wall inside each bedroom and in the hallway outside each separate sleeping area If a bedroom area hallway is more than 9 m long install a smoke alarm at each end DINING ROOM KITCHEN e BEDROOMBEDROOM e e e e BEDROOM LIVING ROOM Typical Two Storey Home Install a smoke alarm on the ceiling or wall inside each bedroom and in the hallway outside each separate sleeping area If a bedroom area hallway is more than 9 m long install a smoke alarm at each end Install a smoke alarm at the top of a first to second floor stairwell L SENN N BEDROOM BEDROOM K Ron E ee gae Key e Smoke Alarm A Smoke Alarm with False Alarm Control IMPORTANT SMOKE ALARM PLACEMENT AND EXCEPTION INFORMATION Install a smoke alarm as close to the centre of the ceiling as possible If this is not practical mount no closer than 10 cm 4 inches from a wall or corner Also if local codes emma fm allow install smoke alarms on walls between 10 and 30 cm 4 and 12 inches from ceiling wall intersections Install a minimum of two smoke alarms in every h
15. out four 4 times a second The alarm may sound for up to 10 seconds after releasing the Push to Test button NOTE If smoke alarms are interconnected all smoke alarms should sound an alarm within three seconds after any test button is pushed and the tested smoke alarm sounds 3 If smoke alarm does not sound turn off power at main fuse box or circuit breaker and check wiring Retest smoke alarm A DANGER If alarm horn sounds and smoke alarm is not being tested the smoke alarm is sensing smoke THE SOUND OF THE ALARM HORN REQUIRES YOUR IMMEDIATE ATTENTION AND ACTION MAINTENANCE AND CLEANING In addition to weekly testing this alarm also require periodic battery replacement Regularly clean smoke alarm to remove dust dirt and debris WARNING Alarm comes equipped with a dust cover which prevents dust and debris from damaging the unit during construction or remodeling Remove dust cover before operation Alarm will not operate properly while covered A DANGER ELECTRICAL SHOCK HAZARD Turn off main power at fuse box or consumer unit by removing fuse or switching appropriate circuit breaker to OFF position before replacing battery or cleaning smoke alarm BATTERY REPLACEMENT A CAUTION Danger of explosion if battery is incorrectly replaced Always turn off power to smoke alarm before replacing battery Replace battery at least once a year or immediately when the low battery signal sounds once a minute even though th
16. this alarm in area where water or other liquids may enter the alarm HOW TO INSTALL THIS SMOKE ALARM DANGER A WARNING AX WARNING ELECTRICAL SHOCK HAZARD Turn off power at the main fuse box or circuit breaker by remov ing the fuse or switching the circuit breaker to the OFF position and securing it Mains operated smoke alarms should be installed by a qualified electrician in accordance with the Regulations for Electrical Installations published by the Institution of Electrical Engineers BS Failure to install this smoke alarm correctly may expose the user to shock or fire hazards The smoke alarm its associated supply and interconnect wiring must be installed in accor dance with BS 7671 published by the institution of Electrical Engineers Install smoke alarm on a wall ceiling standard electrical box or surface mount ing pattress 1 Align mounting plate with mounting holes of standard electrical box or surface mounting pattress For siting on wall or ceiling use mounting plate as template to mark holes Drill holes for wall or ceiling only and insert supplied screw plugs into holes until flush with wall or ceiling 2 Secure mounting plate to electrical box pattress wall or ceiling Diagram illus trates fixing mounting plate to electrical box 3 Connect blue wire from connector plug of smoke alarm to neutral black or blue mains power wire 4 Connect brown wire from connector plug of smok

Download Pdf Manuals

image

Related Search

Related Contents

Manual - Test Equipment Depot  InFocus IN3116 User's Manual  Guía del Usuario  Bedienungsanleitung - sht - heiztechnik aus salzburg  Enregistrement du nouvel album d`Ursus Minor Appel à  DOWNLOAD Catalogo Industria D4  OPERATION MANUAL - AMETEK Programmable Power  Avaya 555-250-701 IP Phone User Manual  Output Binary Electrical Function Module  Samsung LN-R1742 User's Manual  