Home
SERVICE MANUAL
Contents
1. Standby 2 Press On Off key 3 Setupfunction keyto 4 Select proper fan speed by actual situation TECHNICAL SPECIFICATIONS AIR CONDITIONER ITEM UNIT PAC 10000DB OUTER DIMENSION REFERENTIAL USING AREA 13 19 RATED VOLTAGE 220 240 50 524W 897H 347D RUNNING VOLTAGE 198 264 COOLING CAPACITY T U 10000 DEHUMIDIFYING CAPACITY RUNNING CURRENT 4 71 POWER CONSUMPTION ee INDOOR AIR VOLUME 420 1 8 MODEL KETC154ELBABA INPUT POWER 950 975 OPERATING OMPRESSOR c yc E 25 450 PROTECTOR MRA90255 9079 LOCKED ROTOR AMPS 16 5 MODEL WTC 13G INDOOR OUTPUT MOTOR POWER 30 CYCLE 1 400 MODEL WTC 43G OUTDOOR OUTPUT MOTOR POWER 43 e 1 5 450 MODEL WA90S2 TURBINE OUTPUT 12 FAN MOTOR POWER CAPILLARY 2 6 O D 1 4 LD 950 L EVAPORATOR 2R11S17FPI CONDENSER 2R13S16FPI REFRIGERANT 440 APPLICABLE AMBIENT TEMPERATURE WEIGHT AIR CONDITIONER TECHNICAL SPECIFICATIONS ITEM UNIT PAC 10000DB 460W 780H 320D 137 19 220 240 50 207 253 9000 1 6 5 0 900 320 NK134PL12C 738 762 25 370 MRA12012 12026 19 WTC 13G 30 1 400 WTC 43G 43 1 5 450 WA90S2 12 2 6 O D 1 4 I D 600 L 2R11S17FPI 2R13S16FPI 440 18 35 32 OUTER DIMENSION REFERENTIAL USING AREA RATED VOLTAGE RUNNING VOLTAGE CO
2. AT e Easy operation Time onor Time offmode Timersetting 1 12 Hours Temperature setting 16 32C ey On Off Timer Key In running mode Auto switch off In standby mode Auto switch on Operation for auto switch on off A Auto switch off 1 To beoperated in cooling orfan mode 2 Press Auto on off key for machine s stopping operation after 1 2 3 12 hours B Auto switch on 1 Be sure that machine isin standby mode power cord is securely plugged 2 Press Auto on off key for machine s starting operation after 1 2 3 12 hours Set up of Function key Temperature 8 Timer set up key dehumidification mode Coolingor Dehumidification mode e NAME OF THE PARTS Full Tank Indicator Cool lamp ison whenin See thetroubleshooting ecole meds when the lamp ison Dry lamp ison whenin Fan on when in fan mode v C cool D High A O Dry O Med O Fan 0 tow os Mode efe 5 Fan Speed Key On Off amp MED amp LOW eO peration Symbols Operation procedure conditioning 1 Make sure power cord is properly connected Standby 2 Press On Off key 3 Setup function key to air conditioning if necessary 4 Select proper fan speed by actual situation if necessary 1 Make sure power cord is properly connected
3. K THE POWER WON T START NO POWER POWER TRIPPED SWITCH IN PLUG AND SOCKET RE PLUGING THE ARE LOOSE POWER SUPPLY CORD TESTING BY TIMER FAILURE ELECTROSCOPE CHANGE THE PROTECTOR FAILURE PROTECTOR CHANGE THE CAPACITOR FAILURE CAPACITOR WIRING IS LOOSE RE CONNECTING CHANGE THE AIR CONDITIONER WITH 15KG CM NITROGEN GAS FROM LOW PRESSURE SIDE AND DETECT THE LEAKING POINT BY SOAP USE OXYACETYLENE AND PLUS 5 RUNNING THE VACUUM HANGE LANT AND SILVER SOLDER TO WELD THE EVACUATION FOR MORE 1 TEST CRACKEDPOINTS THAN 15 MINUTES RUNNING TEST CHANGE THE SWITCH AIR CONDITIONER COMPRESSOR WON T WON T COOL START PROPERLY REFRIGERANT LEAKAGE TROUBLE SHOOTING SYSTEM APPEARANCE OUT WARD control panel FRONT SIDE Air outlet Handle hole Front panel 0 WARD COVER e HOSE CONNECTOR FIX TURE L FIX TURE DISCHARGE GRILLE 4 E COMPLETE Gal FIX TURE s POWER SUPPLY DRAINAGE PIPE amp CAP Wait for the power return Connect the plug Provide repairment Press the main switch Decrease the setting tem
4. NEW WIDETECH SERVICE MANUAL PORTABLE AIR CONDITIONER PAC 10000DB Important points on service and flow chart for inspecting and repairing the unit Appearance out ward Troubleshooting Functions and control panel Technical specifications Refrigerator system diagram and schematic wiring Exploded view 8 Parts list 2 This manual is for the use of technical personnel entrusted with maintenance 220 240 H Widetech reserves the right to change this dehumidifier s 0 0 50 casing circuit and parts without notice IMPORTANT POINTS SERVICE Please follow these instructions carefully Unplug the unit to avoid any danger from electric shock before disassembling the unit for repair e If thereis any sound ofthe refrigerant circulating when in operation avoid touching the cooling coils f you need to perform any welding or soldering be sure you are ina well ventilated area e Only aqualified professional should perform any welding on the unit e When repairing the unit the specifications listed in this manual must be strictly adhered to whenreplacing any components 9 When replacing any electrical components they should be factory approvedunits Be sure that any electrical components are properly wired and in place FLOW CHART FOR INSPECTING AND REPAIRING THEUNIT AIR CONDITIONER CHEC
5. O MATERIALCODE PARTSNAME QUANTITY PRICE 1 0 BASE PANASS Y es ae A7402 010 TURING WHEEL A5401 010 A 11 DRAIN BUCKET A5408 010 H 11 DRAIN BUCKET COVER A5410 010 A 11 RENK FLOAT MICRO SWITCH DRAINAGE PIPE SOFT CAP A5404 010 A2506 020 V02P11 100 7307 010 7 10 5001 070 11 DRAINAGE PAN FAN MOTOR 11 12 A5311 030 A 22 BLADE STRIKE COMPRESSOR ASS Y 1 CONDENSER 4 4 SERVICE DISCHARGE PIPE SUCTION PIPE STRIKE STRIKE FAN MOTOR STRAINER COMPLETE 23 A5301 070 A 22 FAN CASING A5301 090 A 22 A5304 050 A 22 FAN CASING BLOWER WHEEL CAPACITOR PLATE TERMINAL BLOCK EVAPORATOR A3000 430 A5802 410 A3202 080 A3404 140 A3408 010 A6202 010 A6208 390 A6227 510 A5802 070 A5802 080 A3000 360 A2509 320 A5700 010 A2525 010 A3400 130 A6204 220 A5802 030 33 6602 0400 STRIKE FANMOTOR 1 34 35 A5301 110 A 22 FANCASING J 9 A3000 330 PARTSLIST NO MATERIALCODE PARTSNAME 36 As301 130 A 22 FANCASING 1 37 5304 070 22 BLOWERWHEEL 1 38 4250 060 CAPACITOR 1 39 2525 020 TERMNALBLOCK 1 40 A5900 010 TOP BOARD 5802 020 STRIKE 5802 010 STRIKE strike ass 85 44 002 3 45 000 3 46 096160 cowmotsowp 3 47 0700200 POWER SUPPLY CORDGo
6. OLING CAPACITY DEHUMIDIFYING CAPACITY RUNNING CURRENT POWER CONSUMPTION INDOOR AIR VOLUME MODEL INPUT POWER OPERATING OMPRESSOR LOCKED ROTOR AMPS MODEL INDOOR OUTPUT MOTOR POWER OPERATING CYCLE MODEL OUTDOOR OUTPUT MOTOR POWER OPERATING CYCLE MODEL TURBINE OUTPUT FAN MOTOR POWER CAPILLARY EVAPORATOR CONDENSER REFRIGERANT APPLICABLE AMBIENT TEMPERATURE WEIGHT CAPILLARY CONDENSOR AIR FILTER WATER PADDIE STRIKE WATERMOTOR PAC 10000DB 220 240V 50 Hz REFRIGERATOR SYSTEM DIAGRAM INDOOR RADIATOR DRUM INDOOR MOTOR INDOOR RADIATOR FAN OUTDOOR RADIATOR DRUM OUTDOOR RADIATOR FAN OUTDOOR MOTOR LIQUID ACCUMULATOR COMPRESSOR SCHEMATIC WIRING DIAGRAM SENSOR MICROS W OUTDOOR RED COMPRESSOR RED MOTOR z CAPACITOR CAPACITOR CAPACITOR BLUE 5 G 6069 090906009 OO 7 Br lt AN 77777 Tit 72 gt A 7 N OUIA EN ty fu 0 25 time NAN 5 6 52 9 KY ACCESSOR PAC 10000DB EXPLODED VIEW PARTS LIST N
7. perature Remove any obstacles Provide repairment Turn off the appliance remove the plug and contact the service center Close the window Remove switch the source of heat Decrease the set temperature Clean the filter Clean the air filter Change the purifier filter if necessary Do not make the appliance operating attoo low temperature below22 C Provide repairment TROUBLESHOOTING There is a powerfailure plugis not connected The timeris unable to work The main switch has not been pressed The settemperature is too close to the room s temperature There is something blocking the suction vent on the back of condenser The fan on the condenser is blocked Malfunction There is a window opened There is a source of heat operating in the room burner lamp etc or the room is crowded The airfilter is clogged The capacity of the air conditioner is not suitable for the conditions or size of the room The evaporatoris frozen The compressor blocking device has been loosen the copper pipe is getting in touch with the body of the set 3 PROBLEM POSSIBLE CAUSE REMEDIES The air conditioner doesn t work The air conditioner works for short period only The air conditioner switches are off constantly The air conditioner works butit does not cool the room The applianceis very noisy and vibrates violently IU 8 2 AY
8. wpLETE 1 0000 ag 10000 PME T 3 T 51 52 0260000858 ore 1 53 0060888 FRONTPANEL 54 6002080888 screw 3 55 Ac102 070 A88 screwToecover 3 se asosowAss Frue L 1 T j 57 0200160888 neancovER sa arororAss arrimer 3 se arssomAss 60 asiorosoass ow x L 3 62 0200100085 TOPCOvERPLATE A6200 010 HEATEXHAUSTHOSECONNECTOR 1 20088 Frue O 3 Fes aeo o eare T 3 PME TL 3 T Fez asemos xss Frue 68000085 on L 69 00 00 5701000 a 10 1 1 QUANTITY PARTS NAME CARTONBASE MATERIAL CODE 7105 120 06 9 PARTSLIST
Download Pdf Manuals
Related Search
Related Contents
Hoja Técnica - Rodacal Beyem D-Link Air DWL 650 802.11b Wireless Adapter D-Link AC1200 ll-2000 man english.qxd Samsung M181DN Manual de Usuario Philips SPA2200 User's Manual Sony XR-C102 User's Manual Copyright © All rights reserved.
Failed to retrieve file