1. Ne 4 Stop bits fi 7 Flow control RAES 13 AR 727i already gets IP address now shown as follows Note that save it after set all parameters IP Address 192 168 061 127 Gateway IP 192 168 081 254 Netmask IP 255 255 255 008 TCP Port 1621 Remote IP 192 168 061 001 Password a AR 7271 Ver 1 09 Local IP Gateway IP Netmask IP ICP Port Remote IP Password Save gt Quit OFF DIP SW 1 or Enter a choice 14 Power off Then switch DIP SW 2to OFF position take away communication IC Chip on the U3 position of the PCB and AR 701CM Networking 3 6 Get IP address by AR 701CM COM Port connects to PC At first PCB diagram as follows and Connect AR 701CM to the HOST of the PCB Switch DIP SW 1 to OFF position Switch DIP SW 2 to ON position Serial Setup Mode Switch JumperJ2 J3 J4 and J5 to RS 485 position 1 To modify parameter on the AR 727i through the Hyper Terminal function of the Window Start gt Programs gt Accessories gt Communication gt Hyper Terminal 2 Click Hyper Terminal Shown as follows HyperTerminal by Hilgraeve Monroe Michigan USA For more power and convenience upgrade to hot new i HyperACCESS TODAY Developed for gmmmimntsatasserntneseruetnscrss z Microsoft Upgrade Info opeahtt 93s by Hilgraeve Inc A Higreve Inc eraranta 3 key in any temporary name It is not important matter
2. Connection Description E 2 x a New Connection Enter a name and choose an icon for the connection 4 Choose which COM port that AR 701CM connect and click OK to exit Connect To E 2i x D 123 Enter details for the phone number that you want to dial Country region T awan Soh Area code 02 Phone number COMI COM2 TCP IP Winsock Controller FE CE GA EOR RS 485 panel S ee 7 gs i IRHAT Pieris r 5 Set Port Settings to 9600 8 None 1 None and click OK to save Port Settings Bits per second 9600 Data bits E gt Parity None Stop bits hi gt Flow controt None O oOo O Restore Defaults File Edt wew Cal Transfer Help 192 168 001 128 192 168 001 254 E3 P 259 255 295 000 829 192 168 001 001 Gateway IP Netmask IP TCP Port Remote IP Password or Enter a choice 7 Please refer above item and enter item on the Oso that set all parameters 8 Note that enter item 6 on the to save parameter after finishing to set parameter 9 Then switch DIP SW 1 and SW 2 to OFF position Please visit our web to get more detail information
3. address is a unique identifier MAC Address 00 E0 4C 00 00 50 set at the factory Forces AR 727CM device s TCP IP protocol software to try to pack serial data received during the specified time into the same data Vv Force Transmit time Millisecond frame Lock Remote IP Address Allows contact with only the specified remote IP address To avoid the hacker use this IP to intercept data when Remote IP Address doesn t receive data Setup Password Console password Changes current baud rate of the AR 727CM s serial port Serial Port Speed 9500 from 2400bps to 57600bps TCP Auto Disconnect Time This device automatically closes TCP connection if there is no V Second TCP activity for the given time Serial Port Hardware An exchange of signal over specific wires which each device V Handshaking RTS CTS indicates its readiness to send or receive data DHCP Selecting the enable option allows DHCP to automatically assign V the AR 727CM s IP address Lock Serial Port Free Run or Freeze Over Defines the amount of data in the serial Ethernet buffer at which Force Transmit Bytes the break condition will be generated and the contents of buffer will be sent out via the Ethernet port 3 5 Get IP address by DHCP Server AR 727i support Auto Configuration of the IP and gateway addresses and subnet mask function but must make sure the DHCP Server is active The steps as follows 1 Power off 2 PCB diagram as follows by using DHC
4. Networking Controller User Guide Q Initial setting 1 Power Off 2 Release the Battery 3 J5 to Clear position J5 to Run after 15 sec 4 Connect the Battery 5 Power On Work Done Node Setting FEES 4 Power Off Node eee 2 Release the Battery gt 3 Set Node number 001 4 Connect the Battery aco SUMTEESS gt 5 Power On f Work Done 003 Gunaan 42 l fo l 033 CTTPUIF 4432 AR 716Ei Configuration 3 1 Reset to Factory Default of the AR 727i Press RESET button more than 5 seconds then AR 727i will restore to Factory Default value Q IP Address 192 168 001 127 Gateway IP 192 168 001 254 Subnet Mask 255 255 255 000 Serial Port 9600 N 8 1 TCP Port 1621 Password none 3 2 DIP Switch Settings IP Resent Description ON DHCP Function AR 727i support Auto Configuration Switch 1 of the IP and gateway addresses and subnet mask function but must 1 32 make sure the DHCP Server is active OFF Switch 2 Serial Setup Mode 3 3 AR 727i s contains three LED indicators as described in the following table LED Name LED Color LED Function Yellow Media is connected eink Off Media is not connected Green 10 Mbps Ethernet connection ek Off Ethernet cable is disconnected or has a short BUSY Red Configuration Setup Off Number EN ACT E BUSY ES bs j a AR 727i 3 4 How to set IP address on the AR 716Ei 3 4 1 Get IP address by using Ne
5. P Function Switch DIP SW 1 to ON position Switch DIP SW 2 to OFF position Switch JumperJ2 J3 J4 and J5 to Net position 3 Power on In begging state the ACT LED will flashing after IP has got ACT LED will off and auto save the new IP address to EEPROM 4 Power off 5 Then Switch DIP SW 1 to OFF position and Switch DIP SW 2 to ON position return to Serial Setup Mode 6 Connect AR 701CM to the HOST of the PCB 7 Power on Networking Controller TCP IP panel 8 To modify parameter on the AR 727i through the Hyper Terminal function of the Window Start Programs gt Accessories gt Communication Hyper Terminal 9 Click Hyper Terminal Shown as follows HyperTerminal by Hilgraeve Monroe Michigan USA gt For more power and convenience upgrade to hot new HyperACCESS TODAY Developed for grusu sania ye a Inc Upgrade Info i Hilgraeve Inc Connection Description E 2 x a5 New Connection Enter a name and choose an icon for the connection 11 Choose which COM port that AR 701CM connect and click OK to exit D 123 Enter details for the phone number that you want to dial Country region 1 een 95 Area code joz Phone number TCP IP Winsock 12 Set Port Settings to 9600 8 None 1 None and click OK to save Comi Properties alx Port Settings Bits per second 3600 Data bits fa 7 Party
6. ss is2 168 1 254 5 Click ok to exit Local Network IP NetMask 255 255 255 0 Writ 6 Install Net727i exe into your PC and run Net727i exe reg 11162 Start Programs soyal software Net727i i MAC Address 00 10 4C 00 00 12 Force Transmit time 0 3000ms 5 Mode 2 03 Later 7 Click Get to get default Local IP Address Gateway Netmask Force Transmit Bytes 1 32 Be C Server Mode and TCP Port Cilent Mode Remote IP Address 192 168 1 1 Cilent Mode 8 Change new address and parameters then click write Cilent Mode Remote TCP Port O Connect Event 9 switch DIP SW 1 and SW 2 to OFF position Pi rer crest ices oy VOET Pacayal Setup Password 0 8 Characters l CTS Active State Remark Serial Port Speed E Lock Serial Port How to know PC s IP Address Win98 A ra eee Free Run Start execute enter winipcfg I Serial Port Hardware Handshaking RTS CTS C Freeze Over How to know PC s IP Address Win2000 ee Start Programs Accessories Command Prompt Ready C gt ipconfig ee Local IP Address 192 168 001 127 Defines own IP Address of the AR 727CM Wiese i 192 168 001 254 Defines the IP Address of the default gateway Local Subnet Mask 255 255 255 000 Defines the IP Address range for the local network segment TCP Port The TCP port that other devices must use to contact this device To avoid conflicts with standard TCP ports The MAC Media Access Control
7. t727i software Usually the network of some companys don t built in the DHCP Server Therefore we can use the following method to get default IP address and modify it The steps as follows 1 Press RESET button more than 5 seconds The BUSY LED will flash 5 times thenAR 727i will restore to Factory Default value 2 Open explorer click My Network Places and press right key to open operties I ioixi File Edt Wew Favorites Tools Halp e E Peak gt Arh PFoders G a E X A E Address KE my Network Places C Folders x Name s Comment a Desktop ladd Network Place Conmacts to shared folders We LAJ My Documents Entire Network C My eBooks Fy Computers Near Me Displays computers in your work 2 My Pictures Computer Recycle Bin 3 object s Please visit www soyal com to download the operation manual for more detailed information AR 716E is also allowed to operate through software Please contact your supplier to acquire it Fe CE MA SO Networking Controller User Guide 3 Click Local Area Connection and press right key to open Soyal 7271 Sertai Device Setup U Get AR 727i at IP 192 168 1 127 Password Properties Then double click Internet Protocol TCP IP to open Properties Paramet 4 Click Use the following IP address and enter IP address en ae IP Adis 192 168 1 177 192 168 001 64 Subnet mask 255 255 255 0 Local Gateway IP Addre