Home

USER'S MANUAL

image

Contents

1. 2 10m 1 3 jim 1 Piezo Pt100 E 5 mwater h 3 2 Capacitance Pt100 S 10mwaterh 4 90 m 9 gt 9m 9 Piezo threaded Z 20 mwaterh 5 100 m A Om 0 Piezo threaded Pt100 M The order code of an Ex version should endin Ex 50 mwaterh 6 200 m B e 10m 1 Can be set within the range on special request 100 mw h 7 300 m G dl 200mwh 8 S 90m 9 Cable terminal box NAA 101 Optional to be ordered separately TYPE Cable terminal boksz with OVP NAA 102 Cable holding assy NAA 105 Cable mounting wedge clamp NAA 209 Sewage adapter NAW 104 for NP types OVP units OVP12 33 outdoor OVP32 33 DIN rail 2 3 DIMENSIONS NIVOPRESS NP NE PROBE NIVOPRESS NC NS PROBE NIVOPRESS NM NZ PROBE CABLE HOLDING WEDGE CLAMP NAA 209 CABLE TERMINAL BOX CABLE HOLDING ASSY SEWAGE ADAPTER NAA 101 s NAA 102 NAA 105 NAW 104 breathing capillary 11 2 BSP 21 3 OVP 32 33 OVERVOLTAGE PROTECTION UNIT 62 min 100 mm 3 INSTALLATION For fastening the cable use cable mounting wedge clamp NAA 209 that provides a solution for hanging the cable without slipping and risk of rupture For the NP NE types the NAW 104 sewage adapter can be snapped in the place of th
2. the cable holding assy then place the probe to the desired level and finally fasten the cable holding assy 6 MAINTENANCE REPAIR The unit does not require regular maintenance In some instances however the probe may need occasional cleaning to remove surface deposits within the protective cap that can be easily snapped off Do not touch the sensor membrane Repairs during or beyond the guarantee period are to be carried out solely by the Manufacturer Equipments sent back for repair should be cleaned or sterilised by the User The User must declare that the above has been carried out 7 STORAGE CONDITIONS Ambient temperature 10 C 50 C Relative humidity max 85 8 WARRANTY All Nivelco products are warranted free of defects in materials or workmanship for a period of two years from the date of purchase as indicated in the Certificate of Warranty 1 NAA 102 OVP12 33 IN OUT aD Y XE RY Potecting mg electrode o tj 5 i npk2110a0600h_04 February 2008 Nivelco reserves the right to change technical data without notice
3. Thank you for choosing a NIVELCO instrument We are sure that you will be satisfied throughout its use NIVOPRESS HYDROSTATIC LEVEL TRANSMITTER 1 APPLICATION The NIVOPRESS N submersible hydrostatic level transmitters are applicable for the continuous level measurement of clean or chemically faintly contaminated liquids in bored wells open reservoirs or tanks The NC type is recommended for level detection of polluted water The NIVOPRESS is easy to install in already existing tanks and in deep bored wells and is especially recommneded for controlling of submersible pumps The use of the supplemental accessories is recommnended Using the NAW 104 sewage adapter direct contact between the sewage and the diaphragm of the built in pressure sensor can be avoided Versions with built in 4 wire Pt100 temperature sensor are also available The NOK 300 0 Ex types can be used in explosion hazardous environment 2 TECHNICAL DATA PROBE USER S MANUAL Two wire Three wire NPK NEK NZK NMK NPH NZH 0 200 m water head 0 20 m water head Coe WAIST f Ranges head See ordercode 20x h lt 3 mwh 3x 10x gt 3 mwh 0 10 V 0 V lt 80 mV a measured to the power supply NCK NSK NCH Overload allowed versus range 3x Outputl Built in temperature sensor NE NM NS types Pt100 B class 9 30 VDC NPK Ex 12 30 V DC TAi OVDE Max load U U U power supply Rmn m
4. Warranty Declaration of Conformity NAA 101 cable terminal box Intrinsical safety ACCESSORIES Cable terminal box NAA 101 Dimensions 93 x 93 x 55 mm Ingress protection IP 65 Operating temperature 40 C 70 C Material Plastic Cable gland M20x1 5 cable 5 10 mm Elektromos csatlakoz s Terminal block for cable with max cross section of 2 5 mm Cable terminal box with overvoltage protection NAA 102 Data See NAA 101 Electrical data See OVP Cable mounting wedge clamp NAA 209 Max mech Load Operating temperature With cable length up to 300 m 20 C 60 C Overvoltage protection OVP12 33 OVP32 33 Mounting outdoor DIN 35 mm rail Dimensions 72 x 42 x 19mm 62 x 65 x 18 mm Ingress protection IP 54 IP 20 Breakdown voltage 33 V Absorbed energy 600 W 1 ms Serial resistance 13 ohm Leakage current only for 2 wire 4 20mA equipments lt 10 pA 2 2 ORDER CODE NIVOPRESS N TYPE CODE OUTPUT CODE VERSION CODE RANGE CODE CABLELENGTH CODE CABLE LENGTH CODE Capacitance c Two wire 4 20 mA K Normal 2 1 mwaterh 1 Om 0 g Om 0 Piezo P Three wire 0 10 V H Ex 3 2mwaterh
5. e plastic protecting cap STEPS OF INSTALLATION Feed the special cable through the glands arrange proper length of cable and fasten the cable with the glands Excessive cable parts has to be wound on a pipe with a min diameter of 100 mm The special cable must not be cut short Let the probe down to the lowest possible point as only the height of the liquid above the probe will be measured MOUNTING EXAMPLE For connecting the special breathing cable and the signal cable use the cable Z terminal box NAA101 accessory or NAA102 optional with IP65 that accommodates the cable end in an ambience free of dust and humidity Fasten the cable mounting wedge clamp e g by the use of 2 pcs of M4 screw to a plain surface In open air or industrial applications the transmitter should be protected against transient surges overvoltage NAA 101 The GND of the OVP must be connected with the shortest possible wire and NAA 102 without direction changes to the protecting ground In this case it is suggested the NAA 102 terminal box with OVP is installed close to the location of the measurement At the opposite end of the cabling the use of an additional over voltage protection OVP12 33 or OVP32 33 is advised close to the processing i E J unit 4 WIRING TWO WIRE THREE WIRE TWO WIRE Pt100 Cable core Color Shielding Yellow Positive power supply Red Black with an N
6. egative power supply additional blue colored insulation Voltage output 3 wire type Pt100 sensor current drive Pt100 sensor current drive Uncolored Pt100 sensing Pt100 sensing Breathing capillary Uncolored TWO WIRE 4 20 mA THREE WIRE 0 10V DC overs A a VR WAR T z 8 2 Ss N wiring of wiring of NAA 101 NAA 102 ALWAYS LEAVE THE BREATHING CAPILLARY FREE NAA 101 WIRING OF OVP 12 33 WIRING OF OVP 32 33 Ni D ouT1 IN1 IN2 inputs LE GND OUT1 OUT2 outputs N2 OUT GND grounding 4 1 SAFETY REGULATIONS FOR THE EX APPROVED UNITS 11 C 12 D inputs 01 F E outputs A B H G grounding The Ex type hydrostatic level transmitter must be operated in intrinsically safe circuit only see values in technical data for Ex approved units The metal housing of the device must be connected to the EP network using the connection cable marked with 1 INSTALLATION EXAMPLE USING OVP UNITS PDF 401 OPTIONAL PDF 501 OVP12 33 3 OVP32 33 4 20 mA 12 30V DC 5 PUTTING INTO OPERATION ADJUSTMENT The unit installed and wired according to the specification is immediately operable however the specified accuracy will be reached in six hour time with short cable and in twenty four hour time with a cable of 300 m length If correction of insertion lenght is needed loosen
7. t gt 5 kohm Umin min transmitter voltage 0 02A Current lt 6 mA Accuracy 0 55 25 0 5 Built in 4 wire temp sensor NEK and NSK types only Temperature coefficient lt 0 1 10K lt 0 2 10K Operating temperature 10 60 C 0 60 C 10 60 C Mechanical connection NAA 209 cable mounting wedge clamp NZ and NM types BSP thread Ingress protection IP 68 Electrical protection Class Ill Electrical connection Shielded cable with breathing capillary 7 mm Wire cross section 0 34 mm Cable length 0 300m_ see ordercode Power supply 18 30 V DC f k oo Manufacturer NIVELCO Process Control Co H 1043 Budapest Dugonics u 11 Phone 36 1 889 0100 Fax 36 1 889 0200 e mail sales nivelco com e www nivelco com NPK NEK 22x145 mm NPH 2 ree Probe dimensions 40x140mm NZK NMK 38x152 mm NPK NEK probe 0 2 kg NZK NMK probe 0 3kg NZH 38x152 mm Probe 0 4 kg Cable 0 06 kg m Sensor 1 4404 Al2O3 ceramic 1 4404 Probe 1 4571 Cable coating Polyurethane Sealing VITON FKM Protecting cap probe 0 2 kg 2 1 ACCESSORIES special order max 75 C ADDITIONAL DATA FOR EX APPROVED MODELS Tyoe NPK 300 0 Power supply 12 30 V DC Ex marking I1 G EEx ia IIC T6 Ui 30 V 100 mA Pi 0 8 W Ci 20 nF hx 0 04 nF Li 100 pH h x 0 9 pH h cable length User s Manual Certificate of