Opal-RT OPC Server User Guide
Contents
1. Opal RT OPC Server User Guide Version 1 0 Opal RT Technologies Technical Support 2010 Opal RT Technologies OPC Server 2010 Opal RT Technologies Inc All rights reserved for all countries Information in this document is subject to change without notice and does not represent a commitment on the part of OPAL RT Technologies The software and associated files described in this document are furnished under a license agreement and can only be used or copied in accordance with the terms of the agreement No part of this document may be reproduced or transmitted in any form or by any means electronic or mechanical including photocopying recording or information and retrieval systems for any purpose other than the purchaser s personal use without express written permission of OPAL RT Technologies Incorporated Documents and information relating to or associated with OPAL RT products business or activities including but not limited to financial information data or statements trade secrets product research and development existing and future product designs and performance specifications marketing plans or techniques client lists computer programs processes and know how that have been clearly identified and properly marked by OPAL RT as proprietary information trade secrets or company confidential information The information must have been developed by OPAL RT and is not made available to the public without the express
2. customer OPC server and apply it to the RT LAB real time model Implementation of the dataflow The TestDrive interface retrieves the data from the customer OPC server by using a read access type from the customer OPC server TestDrive provides this data to the real time model by using a control display for control signals and for parameters Note that it is not possible to get a data from the customer OPC server and to apply it to an acquisition signal ie it is not possible to force an acquisition signal Component Type of signal 1 Type of signal 2 Type of signal 3 Access Type of the LabView item Read from customer OPC server TestDrive interface LabView item A control Not possible A control RT LAB real time model A control signal An acquisition signal A parameter Table 3 From the TestDrive interface to the real time model See How to create a TestDrive OPC server compatible LabView panel Reading a signal from an OPC server section Technical Support 2010 7 Opal RT Technologies OPC Server How to create an OPC server configuration file The first step toward the OPC server integration with RT LAB is to configure Opal RT OPC server to match the simulation s requirements This is done by launching the RT Lab OPC Server Each component of the configuration window is described below Opal RT RT Lab Version Automatic v Model C Load if neededin Hardware Synchro
3. og ttdemol sc_user_interface port og ttdemol sm_computation Actua go ttdemol sm_computation Actua go ttdemol sm_computation Actua ttdemol sm_computation Comrr amp ttdemol sm_computation Comrr amp ttdemol sm_computation Comrr o ttdemol sm_computation D erive ao ttdemol sm_computation Gain t go ttdemol sm_computation Gain t go ttdemol sm_computation Gain t itdemol sm computation Gain im 7 pana 2 Lill Back Cancel Help Figure 14 Server explorer wizard signal list Click Finish If successful the project explorer should display a Wizard item with the group name the user has defined under the RT Lab OPC Server Each item should be displayed under this wizard RT Lab OPC Server in Name Device Item Item ID Value Timestam ualit amp Wizard Group f rtdemotjsc_ rtdemot sc_user 1 15 02 59 9700 Value good amp ttdemot sc_user_interfacef port rtdemotsm rtdemotjsm_com 0 005 15 02 59 970 Value good vtdemot sm_computation Actuator response time DelayTime l Qitdemotjsm rtdemot sm_com 0 15 02 59 970 value good A Ae lilies RA cere i o rtdemotjsm rtdemoljsm_com 1 15 02 59 970 Value good a Sai k EA TRS rtdemotjsm rtdemoljsm_com 1 15 02 59 970 Value good 6 rtdemo1 sm_computation Commande OPC Value n eE n ta cla A AT ttdemotjsm rtdemol sm_com 1 15 02 59 970 Value good Figure 15 Final server explorer wizard signal list with pro
4. than one Opal RT OPC servers are running To solve the problem reset the real time model close the accessible OPC server found in the icon tray and manually kill the remaining OPC server s that are still running Load the model again and launch the Opal RT OPC server Verify that only one is running OPC server exe Technical Support 2010 25
5. with a standard server explorer Note that it is possible to use any server explorer that may be at hand The following section shows how to use the server explorer provided with Opal RT s OPC server Opening the server explorer brings a project explorer with all the active servers detected The project explorer to the left should normally display RT Lab OPC Server if it is running Select the RT Lab OPC Server in the project explorer Click the Wizard button or right click on the server and select Wizard New Project Server Explorer 2 4 1 File Servers Edit View Options Help Dll el fol 4 My Computer YF LookoutOPcsServer OPcDemo Reeeceeseeeeoeoecoceeceeoeoececoceeoe Variable Engine Wizard amp My Network Places Connect to server Properties Add Edit Groups Figure 13 Server explorer wizard launcher Click Next to connect the server explorer to the Opal RT OPC server If successful a message should indicate that you are now connected to this server You can then change the Group Name to your convenience and the Update Rate of signals in milliseconds Click Next to complete the wizard s setup If successful the Selected OPC Items should display signals parameters of the real time model Technical Support 2010 20 Opal RT Technologies OPC Server g Press the Finish button to create the selected OPC Item s Available OPC Items Selected OPC Items a
6. 8 How to create a TestDrive OPC server compatible LabView panel 12 Reading a signal from an OPC server cc cece eee eec cent eee tenancies 12 Writing a signal to an OPC Server 0 cece cece cece ee ee tenet ena e eee eeennes 13 How to run the complete configuration 0 c cece ence cece e eect eeeeeeenteees 14 How to use the OPC server prompt and the Server Explorer 0 000008 17 OPC server Prompt ois escoria aaa gia be toads yas ea Labs RI Sea eg yaa we 17 Server Explorer chai esnaera E weosa Wak AEA whee CoA EA na 20 Eronbleshootine eSa r ses l osu teeter aces a a a NO 24 Technical Support 2010 Opal RT Technologies OPC Server What is Opal RT OPC Server Opal RT OPC Server is an add on to Opal RT RT LAB to interface an external OPC server to a real time simulation Opal RT provides his own fully configurable and integrated OPC server A simple OPC server configuration using Opal RT s solution could be represented with the following figure Opal RT RT LAB Customer Servers Interface es Figure 1 OPC server configuration Component Description RT LAB real time model mdl RT LAB real time model including signals and parameters to exchange with the customer database Opal RT OPC Server Opal RT OPC server connected to the real time model Servers Interface Third party interface allowing OPC servers
7. Q7 in the Troubleshooting section Technical Support 2010 13 Opal RT Technologies OPC Server How to run the complete configuration This part of the procedure can be performed only after the real time model is ready the TestDrive panel is ready and the configuration of the OPC server is ready A Make sure the real time model is compiled and that it loads executes fine in RT LAB Make sure the model is not running before using TestDrive B Make sure the TestDrive panel is running fine in LabView Figure 7 Run the panel in LabView C Open TestDrive and create a new configuration just as it is for a standard TestDrive model Launch the configuration The model is loaded and executed automatically A Configurations C C OpalRTIRT LABIOPC Sorver_Real_Time _ Model Path _Server_Real_Time_Model mdl O i i O This is an OPC server TestDrive configuration v EEDIT move Figure 8 Create and load a TestDrive configuration Technical Support 2010 14 Opal RT Technologies OPC Server D Once the model is running add your panel to the configuration By default the Opal RT OPC server should be launched automatically but the controls indicators will indicate not connected from their small color coded warning indicators E To connect the controls indicators to the OPC server it is required to load the panel a second time This can be done by swapping to another panel and coming back to the one of
8. ck on the control indicator and select Properties 2 Scroll right until you reach the Data Binding tab 3 Set the Data Binding Selection field to DataSocket 4 Set the Access Type field to Write only 5 Select DSTP Server from the Browse scrolling list 6 Select the signal to write URL under Name_of_OPC_server_to_write_to Name_of_signal_to_write 7 It should then appear in the Path field 8 Click OK A small warning indicator rectangle should appear next to your control indicator The small color coded warning indicator next to each control indicator can quickly tell the user if it is connected or not to the server and to the selected item At run time the warning is red when there is no active connection The warning is green when the connection is properly established Slide Slide 2 Po crop on ay Pop tT oy Say O 2 4 6 6 10 0D 2 4 6 6 10 Figure 6 Connected disconnected small color coded warning indicator Note the Opal RT OPC server must be running before setting the URL step 6 This is true for read and for write procedures If it is not already running LabView will try to launch it automatically when you reach this step If the Load if needed in option is unchecked in your server settings the server will not be able to connect to the model with error mentioned in Q5 see Troubleshooting section You need to manually start the model first One more issue can be associated to two Opal RT OPC server running See
9. consent of OPAL RT or its legal counsel ARTEMIS RT EVENTS RT LAB and DINAMO are trademarks of Opal RT Technologies Inc MATLAB Simulink Real Time Workshop and SimPowerSystem are trademarks of The Mathworks Inc LabVIEW is a trademark of National Instruments Inc QNX is a trademark of QNX Software Systems Ltd All other brand and product names are trademarks or service marks of their respective holders and are hereby acknowledged We have done our best to ensure that the material found in this publication is both useful and accurate However please be aware that errors may exist in this publication and that neither the authors nor OPAL RT Technologies make any guarantees concerning the accuracy of the information found here or in the use to which it may be put Published in Canada Contact Us For additional information you may contact the Customer Support team at Opal RT at the following coordinates Tool Free US and Canada 1 877 935 2323 08 30 17 30 EST Phone 1 514 935 2323 Fax 1 514 935 4994 E mail support opal rt com info opal rt com sales opal rt com Mail 1751 Richardson Street Suite 2525 Montreal Quebec H3K 1G6 Web www opal rt com Technical Support 2010 2 Opal RT Technologies OPC Server TABLE of CONTENTS What is Opal RT OPC Servet ccs csceisueece ie ee ea 4 Datafl Weir renere ea rana a e aaar ee a 6 How to create an OPC server configuration file 0 ccc ccc cece cence eee ene
10. e lag can also be induced if Dynamic Acquisition has been selected without forcing the Probe Control reconfiguration Refresh time OPC Lag induced on the Opal RT OPC server side Items count Displays the number of signals and the number of parameters available to the Opal RT OPC server These numbers depends on you mapping LOG Give access to the OPC server logs for more details or troubleshooting gt RT Lab OPC Server Mainnas userdata E_Support OP RT Lab OPC Sending parameters and signals A Waiting For signals and to OPC thread parameters list Configuration finished Waiting For parameters initial m values ic Configuration complete inst 2000 mean 2000 max 2047 Application Log Statistics Refresh time OPAL 2047ms OPC Oms Items count 19 signals 16 parameters Figure 12 Opal RT OPC server log prompt RT Lab Logs related to RT LAB with regards to the Opal RT OPC application OPC Logs related to Opal RT OPC server with regards to the RT LAB application Application Log Logs related to the Opal RT OPC server application debug Technical Support 2010 18 Opal RT Technologies OK HIDE Returns the Opal RT OPC server prompt to the icon tray EXIT Stops the Opal RT OPC server A prompt appears to allow model reset or not Technical Support 2010 OPC Server 19 Opal RT Technologies OPC Server Server Explorer Opal RT OPC server comes
11. election field to DataSocket 4 Set the Access Type field to Read only 5 Select DSTP Server from the Browse scrolling list 6 Select the signal to read URL under Name_of_OPC_server_to_read_from Name_of_signal_to_read 7 It should then appear in the Path field 8 Click OK A small warning indicator rectangle should appear next to your control indicator Meter 43 Knob Properties Meter Select URL X m E Scale Display Format Text Labels oeaan or0 hg slali TE J My Computer me OK o 100 E National Instruments LookoutOPCServer Sie 5 National Instruments OPCDemo Visible Items DataSocket 5 National Instruments Variable Engine 3 A Find Terminal Change to Indicator Description and Tip stop Create Replace Data Operations Advanced Browse host Fit Control to Pane National Instruments recommends that you use data binding through the Shared URL ope localhost RT Lab OPC Server ttdemol sc_user_intetface port Slide 2 Scale Object with Pane Variable Engine Refer to the LabVIEW Hepp for more information about data binding controls I a Representation gt 0 2 Data Entry Display Format Add Needle Scale gt Text Labels A ros o Figure 5 Steps to perform in order to read a signal from an OPC server Technical Support 2010 12 Opal RT Technologies OPC Server Writing a signal to an OPC server 1 Right cli
12. interest It can also be done by unassigning reassigning the panel in TestDrive he panel is now available Panels l TestOPC1TD aed a mcm ae Coe ad the panel once he eated f e file syster Slide y T end Load the panel a second time Q sss Fn EEATT 0 Z 4 6 8 10 i The yntrols displays are now nected and functiona The OPC server is started but the Figure 9 Load the panel and connect to the OPC server F Perform the required tests with the simulation G When done three instances must be resetted TestDrive the real time model and the OPC server Only one rule to follow always reset TestDrive before the OPC server To reset TestDrive File Logout or File Exit from the TestDrive menu To reset the Opal RT OPC server Right click on the OPC server icon in the icon tray and click Restore Click Exit To reset the real time model Both instances TestDrive and Opal RT OPC server will ask if the user wants to perform the model reset at the same time as resetting themselves Any option is functional 3 This is the normal behavior of OPC servers As soon as one client asks for a connection the OPC server is started Therefore as the panel that runs in TestDrive is the client the OPC server is launched Technical Support 2010 15 Opal RT Technologies OPC Server It is also possible to manually launch the Opal RT OPC server This is not recommended when using TestDrive interface as the ser
13. ition Acquisition group from to Select which acquisition groups are concerned by the dynamic acquisition settings defined in the OPC server configuration Get all values then filter Get values one by one Minimal refresh time Select what is the refresh rate of signals parameters in the OPC server in milliseconds RUN Run Start the Opal RT OPC Server Note For a new configuration the Run button is disabled by default The configuration must first be saved the button will then be enabled While editing an existing configuration pressing Run will ask to save or not the edited configuration before starting the server Technical Support 2010 11 Opal RT Technologies OPC Server How to create a TestDrive OPC server compatible Lab View panel Creating a TestDrive panel for OPC server is very similar to creating a standard TestDrive panel The only difference is that some controls indicators added to the panel must be associated to the OPC servers to be used Two possibilities can occur either the display reads a signal from an OPC server read or the display writes a signal to an OPC server write After adding a control indicator in the panel it must be edited in order to read write a specific signal to from a specific OPC server Reading a signal from an OPC server 1 Right click on the control indicator and select Properties 2 Scroll right until you reach the Data Binding tab 3 Set the Data Binding S
14. ject explorer and values Technical Support 2010 21 Opal RT Technologies OPC Server One of the main uses of the server explorer is to test the connection between the OPC server and the TestDrive interface or the real time model by forcing a value from the server explorer and by confirming its change in the TestDrive interface or in the real time model From the signal list 1 Right click on a signal and select Properties BP TLC LIS TLURTIULIST_LUI o g rtdemoljsm Oo rtdemoijsm rtdemot sm_c rtdemotjsm rtdemot sm_c Deactivate Item s rtdemot sm rtdemo1 sm_corny rtdemot sm rtdemoljsm_com 1 Figure 16 Access the properties of a signal Properties Delete 2 Open the Read amp Write AsyncIO tab 3 In the Write section type a value in the value field and press the Write button Settings Properties Read amp Write Sy gl0 Read amp Write AsynclO Read Value Timestamp Quality Status Read Perf microsec Source Poll Rate msec Refresh Perf mictosec write OK Cancel Help Figure 17 Apply a new value to a signal Technical Support 2010 22 Opal RT Technologies OPC Server 4 Observe the control indicator associated to this signal in the TestDrive interface The new value applied from the server explorer should also be found in the TestDrive interface As both executions are asynchronous it may take a litt
15. le bit of time to update or update by gradual steps Note The server explorer must be closed before shutting down the Opal RT OPC server and the RT LAB real time model Else it may freeze until killed manually and the TestDrive interface may return a Permission not granted at load Technical Support 2010 23 Opal RT Technologies OPC Server Troubleshooting Q1 The Run button of the OPC server configuration is always grayed out I cannot run my configuration A1 The Run button is only available when the OPC server configuration is saved File Save or File Save As will allow the user to save his configuration The Run button will then be available Q2 The OPC server log returns DLL opal C OPAL RT RT LAB10 1 dll cound not be found Program halted 094925 982 Debug opal D OPAL RT RT LAB10 1 dll not loadable The shared library was not found 094926 076 Debug OPAL 9102 DLL opal D OPAL RT RT LAB10 1 dll cound not be found Program halted What is the problem A2 This is a known issue When selecting Automatic for the RT LAB version in the OPC server configuration the dll file cannot be found The solution is to manually select the version of RT LAB to use in the scrolling list Q3 The OPC server is always running even after I reset the model and log out What can I do A3 This is a known issue The solution is to manually kill the running server Q4 I am not able to see the signals pa
16. ly a few are required for the OPC server Opal RT RT LAB RT LAB real time model mdi Servers Mapping file filter Interface Opal RT OPC Server Figure 4 Mapping file filter application SIGNALS Select which filter you want to apply to signals to display in the OPC server Filter Description All OPC server displays all signals available in the real time model Mapped OPC server displays mapped from the mapping file signals only None OPC server does not display any signals Table 6 Signals filter description Note Leaving all options unselected is the same as selecting None Technical Support 2010 10 Opal RT Technologies OPC Server PARAMETERS Select which filter you want to apply to parameters to display in the OPC server Filter Description All OPC server displays all parameters available in the real time model Mapped OPC server displays mapped from the mapping file parameters only None OPC server does not display any parameters Table 7 Parameters filter description Note Leaving all options unselected is the same as selecting None SIGNALS ACQUISITIONS TECHNOLOGY Dynamic acquisition Force probecontrol reconfiguration If checked the settings defined in the OPC server configuration for the dynamic acquisition will overwrite the actual model s probe control settings Rate Select the refresh rate of the dynamic acquis
17. nized mode Mapping file He Signals Parameters O all O all Mapped Mapped None None Signals acquisitions technology Dynamic acquisition Force probecontrol reconfiguration Rate Acquisition group from to with 5000 signals per group Get all value then filter Get values one by one Minimal refresh time 0 ms Run Figure 3 Opal RT OPC server configuration window Technical Support 2010 8 Opal RT Technologies OPC Server File Menu File Menu Item Description New Open a new OPC server configuration Open Open an existing OPC server configuration Save Save the currently opened OPC server configuration with a ogp extension Save As Save the currently opened OPC server configuration with a specified name Exit Quit OPC server configuration Table 4 Opal RT OPC server configuration window File menu item description Tools Menu Tools Menu Item Description Convert v1 mapping file Convert OPC Server 1 mapping file to OPC Server 2 mapping file Create new mapping file Create a new mapping file from existing signal and param files Table 5 Opal RT OPC server configuration window Tools menu item description RT LAB Version Select which version of RT LAB to use with the OPC server Note 1 Not all versions of RT LAB are supported You must absolutely use a version of RT LAB supported by the OPC server Note 2 Selecting A
18. rameters in the OPC server The statistic says Items count 0 signals 0 parameters A4 This is caused by a default setting in the OPC server configuration By default the signals and parameters filter both have all options unchecked This is the same as selecting None Edit your configuration file and select All or Mapped if you have a mapping file for signals parameters See also Q6 below Q5 When an OPC server stops running while TestDrive is still running TestDrive freezes and cannot be restored A5 This is a known issue The solution is to manually kill TestDrive Q6 When I observe the Opal RT OPC server Application log I get the following error 114009 217 Debug QOpal Wrapper impl cpp 459 OpalError Model not specified by previous OpalConnect or OpalSetCurrentModel code 9 badf Items count also shows zero signals and zero parameters Technical Support 2010 24 Opal RT Technologies OPC Server A6 This error means that the RT LAB real time model is not loaded and that the Opal RT OPC server is not able to connect to it Stop the server load the model and launch the server again Q7 I am trying to set my control indicator in LabView When I try to set the URL for a signal under the Opal RT OPC server the RT Lab OPC Server tries to connect itself but it never succeeds From the icon tray and the Application log it shows that the server is working fine though A7 This behavior is caused when more
19. to communicate together Customer OPC Server Customer OPC server connected to the customer database Customer Database Customer database including signals and parameters to exchange with the RT LAB real time model Table 1 OPC server component description The configuration shown is a simple connection schematic in which the Opal RT OPC server is connected to a single customer database The real time model is considered a client of the Opal RT OPC server The customer database is considered a client of the customer OPC server A more complex configuration can include multiple customer OPC servers and multiple customer databases multiple clients connected to various OPC servers Technical Support 2010 4 Opal RT Technologies OPC Server Opal RT has demonstrated as a proof of concept that it is possible to use TestDrive or LabView as the servers interface Therefore the configuration detailed in this document will be presented as in the following figure Opal RT RT LAB Customer RT LAB real time Customer model mdl Database Opal RT f Opal RT OPC y Server aul Figure 2 OPC server configuration using TestDrive as the servers interface This guide is intended for users who are already able to build a real time model to use RT LAB to build a panel compatible with TestDrive and to use TestDrive Technical Support 2010 5 Opal RT Technologies Dataflow OPC Server The dataflow must be
20. utomatic allows the OPC server to detect which version of RT LAB is currently used and to connect to it if supported It is recommended to manually select the version to use in the scrolling list though MODEL File Select which real time model to use with the OPC server The browser allows the user to access the computer s file system Edit Open the selected Simulink model in Matlab for edition Load if needed in If checked this option allows the OPC server to load and execute the model with the specified real time simulation mode The load and execution process starts when the Run button is pressed in the OPC server interface Note It is required to leave this option unchecked when running the server interface on TestDrive It is also recommended to leave this option unchecked when running the server interface on LabView and to load execute the model from RT LAB itself Technical Support 2010 9 Opal RT Technologies OPC Server MAPPING FILE File Select which mapping file to use with the OPC server The browser allows the user to access the computer s file system Edit Open the selected mapping file in an XML editor What is a mapping file A mapping file is actually an xml file which acts as a filter on the list of signals and parameters of a model It allows the user to display only filtered signals to the OPC server This option is handy with models that include a large number of signals and parameters and where on
21. vers interface but it can be handy to launch manual tests with LabView as the servers interface 1 Open the RT Lab OPC Server 2 Open the OPC server configuration file generated earlier ogp file 3 Click Run The Opal RT OPC server icon should appear in the icon tray This will launch the Opal RT OPC server Note Launching manually the server before launching TestDrive may lead to a Permission not granted at load Technical Support 2010 16 Opal RT Technologies OPC Server How to use the OPC server prompt and the Server Explorer OPC server prompt The Opal RT OPC server prompt can be accessed as long as the OPC server is running The OPC server icon can be found in the icon tray of your operating system Right clicking on it will bring the Restore option which will open the OPC server prompt Q r OYG 3 03PM Opal RT OPC server icon Figure 10 Opal RT OPC server icon in the icon tray The first window to appear is the Statistic window STATISTICS gt RT Lab OPC Server Mainnas userdata E_Support OP Statistics Refresh time OPAL 2047ms OPC Oms Items count 19 signals 16 parameters Figure 11 Opal RT OPC server statistics prompt Technical Support 2010 17 Opal RT Technologies OPC Server Refresh time OPAL Lag induced on the RT LAB real time model side Excessive lag can be induced if non existing acquisition groups have been set in the OPC server configuration Excessiv
22. well defined in order to use the Opal RT OPC server efficiently How the data is exchanged between the RT LAB real time model the Opal RT OPC server the TestDrive interface and the customer OPC server is the basis of a complete and functional application From the RT LAB real time model to the customer OPC server Goal Take a value from the RT LAB real time model and write it on the customer OPC server Implementation of the dataflow The RT LAB real time model provides the data to the TestDrive interface as for a standard TestDrive application by signal assignation Control signals and parameters can be assigned to control displays only Acquisition signals can be assigned to indicator displays only TestDrive passes the data to the customer OPC server by using a write access type to the customer OPC server Component Type of signal 1 Type of signal 2 Type of signal 3 RT LAB real time model A control signal An acquisition signal A parameter TestDrive interface LabView item A control An indicator A control Access Type of the LabView item Write on customer OPC server Table 2 From the real time model to the TestDrive interface See How to create a TestDrive OPC server compatible Lab View panel Writing a signal to an OPC server section Technical Support 2010 Opal RT Technologies OPC Server From the customer OPC server to the RT LAB real time model Goal Take a value from the