DEX DENDROMETER INSTALLATION AND USER GUIDE
Contents
1. optional calibration kit an inside micrometer The sensor does not need to be calibrated each time it is installed however the zero offset does need to be entered into the bridge command If a change in excitation voltage is made for compatibility with another type of logger the calibration should be performed with that specific set up in order to be as accurate as possible Optional Calibration Kit The calibration kit included in model number DEXCC has a custom anvil fitted to make readings easier for the user The 2cm long extension has a stainless cap nut affixed When calibrating use the set of spherical anvils supplied to fit the calibration tool between the anvils without slippage If necessary use small strips of masking tape inside the anvils to make slippage less likely Remove the masking tape later to make your readings in the field At first one may make readings between 0 7 mm and then fit a calibrated 6mm spacer between the inside micrometer and the custom anvil Then proceed to record values for inside diameters between eight and ten mm Due to the geometry between 11 and 13 mm it is not recommended to routinely count on these readings and thus it is best to leave this off of a calibration curve fit Note that the DEX devices are most accurate between growths of around five to seven mm Installation and Zero Set The zero offset procedure needs to be performed when the absolute size is to be logged If the user only wants gro
2. 0 After the trunk or fruit grows up to 5 7 mm reset the sensor and start a new zero value This is to maintain the fit of the sensor with a minimum of pressure on the plant The sensor is tested to perform up to a 13 mm growth without breaking or loosing the accuracy of the patented flex arm assembly however it is not an ideal geometry and may have difficulty fitting normally between 7 13 mm growth However it is nice to know that if you forget to reinstall the sensor it will not break Do not flex the sensor over the 13 mm expansion or we will not be able to guarantee against breakage in the strain gauges DEX Dendrometer Calibration Procedure Calibration of the DEX range of electronic dendrometers DEX20 DEX70 DEX100 amp DEX200 from Dynamax Inc is most easily performed by using the DEX Calibration Kit Model DEXCC also available from Dynamax The calibration kit includes a high precision inside Micrometer and custom anvil to accommodate the 2cm long micrometer extension arm that is fitted with a rounded cap nut This helps to ensure a firm fit of the micrometer within the dendrometer without the need to apply force to the micrometer by tightening the adjustment screw with the adjusting knob The dendrometer does not need to be calibrated each time it is used however the multiplier and zero offset from the calibration does need to be entered into the bridge command whenever a dendrometer is added or changed in the setup procedure for
3. 2 7 5 mV 60 Hz noise rejection voltage range 03 1 In Chan 04 1 Excite all reps w Exchannel 1 05 500 mV Excitation 06 1 Loc Gage 1 mV mm 07 Mult b Enter the multiplier value 1 Constant supplied on the calibration computation sheet If preferred a 1 0 value records millivolts for purposes of calibration only 08 Offset Z Enter initial value to zero output After logger records a stable number average 1 2 min re enter the negative of the recorded offset value eg 1 348 if 1 348 zero set was recorded 02 P6 01 1 Rep DEX Dendrometer Installation and User Guide 3 02 22 7 5 mV 60 Hz noise rejection range 03 2 In Chan 04 1 Excite all reps w Echannel 1 05 500 mV Excitation 06 2 Loc Gage 2 mV mm 07 Mult b See note above use the multiplier b for sensor no 2 08 Offset z 03 P92 01 0 minutes into a 02 60 minute interval 03 10 Set high Flag 0 output 04 P71 01 2 Reps 02 1 Loc gage 1 mV mm 7 Let the logger run first with the dendrometer installed and collect the data for an average of 15 minutes Retrieve the output data Make a note of the output results as the zero set Z 8 Enter the zero set as a negative offset That is enter the initial value Z into the program as Z The next data collection should be verified to have a zero output 9 Collect data for 30 days or more Then monitor the growth and retrieve the diurnal changes as well as the long term trends 1
4. DEX DENDROMETER INSTALLATION AND USER GUIDE DYNAMAX INC OCT 2003 The DEX20 DEX70 DEX100 and DEX200 are highly precise electronic dendrometers that measure the growth and size of plant stems and fruits The effects of environmental factors on the water balance of plants and stem size variations over time are easily monitored with a temperature compensated dendrometer The DEX is a caliper style device with a full bridge strain gage attached to a flexible arm The output signal is then recorded by a data logger or computer in real time The millivolt sensor output shows both the diurnal and long term growth of the plant This device has been used to test plants under conditions of water stress elevated ozone and other atmospheric pollutants Applications for screening plants for growth rate and stress tolerance are also common Operation of Dex Dendrometers The electronic dendrometers from Dynamax are operable with any datalogger that can make a full bridge resistance measurement All Dynamax sap flow system configurations except the Flow4 may record the DEX Dendrometers as well as Campbell Scientific CR10 CR7 21X and the DL2e loggers from Delta T devices Current Consumption Excitation The principal connections are a differential input measurement one pair per sensor and a single excitation measurement for every 10 to 20 sensors For example the excitation on a CR10 has an output current rating of 50 mA at 1 5 V Each DEX dendromete
5. a logger The DEX range of dendrometers are factory calibrated using DNX10 or CR10X Campbell Scientific dataloggers with an excitation of 500mV If a change in excitation voltage is made for compatibility with another logger the calibration should be performed with that specific set up in order to be as accurate as possible Also be aware that other loggers may also require a DEX Dendrometer Installation and User Guide 4 voltage regulator to maintain a standard excitation voltage with which to supply the dendrometer Calibration Steps To begin a calibration connect the dendrometer to the logger and view the output in real time on the computer screen in front of you A simple logger calibration program for Campbell Scientific loggers DENDROM dld is available from our web site www dynamax com Set the inside micrometer to 0 00mm Adjust the dendrometer with the custom calibration anvil fitted with sufficient firmness so that the micrometer is just held in place without slippage Be sure to place the dendrometer lying flat on a firm bench and maintain this same position throughout the calibration to ensure uniformity for each measurement This will also allow the adjustment arm of the micrometer to rest on the bench and take any strain off it that may cause the micrometer to slip or drop out of the dendrometer Ensure that the voltage output from the micrometer is adjusted as close to 0 00 mV as possible to ensure you receive the full rang
6. e of measurement from your dendrometer Generally a voltage output of 0 100 to 0 400 mV is an acceptable place to start at 0 00mm Now tighten the locking nut on the Adjustment Screw of the Dendrometer Using the DEX Calibration Sheet doc available from www dynamax com record the voltages at each measurement distance Please note due to the scale of the micrometer the graduations marked are actually as follows 10 on the micrometer is 0 20mm 20 on the micrometer is 0 40mm 30 on the micrometer is 0 60mm and 40 on the micrometer is 0 80mm From this point on each 1 mm on the micrometer 1 00mm After adjusting the micrometer at each distance position it carefully in the center of the anvils of the dendrometer where the zero reading was made and record the measurement on the calibration sheet Repeat this for each distance After completing the measurements for each distance as recorded on the DEX calibration sheet transfer these readings to the DEXCAL x s file This spreadsheet is available via our web site www dynamax com it contains an Example Page and a Calibration Template to use Enter the results from the Calibration Sheet into the Column heading Readings The Read Offset is then calculated by subtracting the zero reading from the reading recorded at each distance measured For example if the zero reading was 0 400 mV then 0 400 mV must be subtracted from each reading This is done automatically by the equation in th
7. e spreadsheet The Excel graph is forced through zero and an offset was subtracted For this reason the linear formula is y mx b 0 m cal constant mv mm For your records make sure you update the DEX Model and Serial of the Calibration graph by clicking on the text and editing it Finally to calculate the DEX Calibration Multiplier in mm mV divide 1 by the slope y mV mm to provide the answer in mm mV and again update the graph by clicking on the text and editing it You can then print this page so that you have a hard copy record of the current calibration Also save the calibration file using the Save As function to a meaningful file name such as the date of the calibration e g DEXCAL091400 xls or DEX25 091400 xls if you have multiple sized dendrometers DEX Dendrometer Installation and User Guide 5 In practice the multiplier to convert a signal in mV is set into a logger command so the output is displayed in mm The initial offset may be entered upon positioning the dendrometer on a stem to enable the measurement of absolute size However this is entirely optional since the growth rate is the difference between the initial reading and the subsequent readings DEX Dendrometer Installation and User Guide 6
8. h the suspension line Support the assembly as it is held into position and close the Velcro strap around the trunk 4 Attach the connecting cable to the trunk or stem with a second Velcro strap so that there is slack in the cable Position the cable so that there is a minimum of force on the dendrometer from the weight of the cable Take additional precautions to prevent accidental contact to the cable from equipment animals or people that may pull on the cable and reposition the sensor The use of a fixed stake to support the dendrometer is not recommended because any bending of the plant will cause forces on the flex band to register as noise in the readings If necessary to suspend the dendrometer in a vertical plane as opposed to a horizontal plane in the case of branch measurements or fruit growth studies it is recommended to add two more drill holes on each arm opposite the existing suspension holes These additional holes will aid suspension in a variety of angles 5 Install the dendrometer around the stem and tighten down on the adjustment screw until there is contact between the stem and the clamp Tighten adjustment screw 2 or 3 more turns to apply slight pressure to the stem Tighten the locking nut with a spanner wrench so that the adjuster screw will not turn thereafter 6 Enter the four wire bridge instruction for your logger as follows Programming 1 Table 1 Programs 01 10 Sec Execution interval 01 P6 01 1 Rep 02 2
9. ons about 0 5 uV for DEX70 The user would also need to observe electrical noise reduction methods that would reduce noise below the specified limits of 0 010 mV The simplest noise reduction is to have a slow integration A D converter that matches a multiple of the cycle period of the noise created by line powered equipment be it either 50 Hz or 60 Hz lighting or other sources In the example attached one will find a 60 Hz noise reduction implemented and Dynamax has observed noise reduction to less than a noise level of 2 uV equivalent to 15 microns on DEX100 and 9 microns on DEX70 All users will find it advantageous to use either a 50 or 60 Hz noise rejection along with other usual methods of grounding the conductor shields and DFX Dendroameter Inctallatiann and Tieer Giide 1 so on Hookup A typical datalogger hookup sequence and sensor cable assignments are shown below Gauge 1 Gauge 2 Function DEX Cable CR10 Port DEX Cable CR10 Port Out White H1 White H2 Out Green L1 Green L2 Ex Red Ex1 Red Ex1 Ex Black AG Black AG Shield Bare G Shield G Installation The Dendrometers are calibrated at the time of assembly The Multiplier calculated for each Dendrometer is supplied on a calibration sheet Each dendrometer is identified with a serial number found on the sensor flex band and the certificate should match the serial number Each sensor can be re calibrated by the customer with the
10. r has an input impedance of 350 Ohms and is typically given an excitation of 0 5 V Thus the current consumption at that excitation level is 0 5 350 0 0014 Amps It is a conservative figure to estimate one may connect 35 sensors per excitation port Logger Resolution Input Ranges At a 500 mV excitation level and at a 7 5 mV input range for the logger in this example DNX10 or CR10 the logger resolution is 1 uV which translates to a linear resolution of 0 007 mm or 7 microns The resolution can be improved by increasing the excitation voltage or by using a more accurate logger however it will not improve the accuracy of the sensor The voltage out of the sensor can range between 4 or 5 millivolts so many loggers can use a range smaller than 7 5 millivolts Nevertheless the temperature instability of the device over 20 C is such that temperature compensation would be required to decrease the error of 50 microns see the environmental operating specifications on pg 8 to a value close to 7 microns In the case of indoor temperature stable experiments one may find a greater resolution desirable to achieve accuracy in the 10 micron range For example if one were controlling the environment to no more than 4 C temperature range the 2 5 microns C times 4 C would enable readings with error less than 10 microns In this case the user must select an input range that allows readings with a resolution of at least 2 5 micr
11. wth or diurnal changes zero offset procedure is not necessary The installation process is as follows 1 Find a relatively smooth surface on opposing sides of the trunk or branch to be measured Clean or sand the dead bark from the trunk if it will interfere with a solid contact with the trunk at the point of attachment Select the best fitting anvils supplied with the sensor One anvil is designed to screw into the fixed arm The adjustable screw has a slip in anvil 25mm x 25 mm installed with a light slip on force Adjust the dendrometer screw with the adjusting knob and make a trial fit of the dendrometer on the stem while supporting the device by hand If there is DEX Dendrometer Installation and User Guide 2 a tendency of the device to slip into another position due to the shape of the stem make a note that this will be the best position to affix the sensor 2 Using a circumference tape or a caliper measure the circumference and divide by 3 14 recording the beginning diameter of the trunk This reading will be used as a reference point for the growth readings to be obtained from the dendrometer 3 Attach one end of a 60 cm length of medium test fishing line to the hole drilled in the right arm of the dendrometer and tie the other end to the left arm The holes are drilled into the center of gravity to minimize any support forces on the flex band not related to the trunk or fruit growth Place a Velcro strip around the trunk and throug
Download Pdf Manuals
Related Search
Related Contents
Downloading - TeleDynamics ANNEXE 1 - Ministère de l`écologie, du développement durable et Stratagy DK Voice Mail Delta U4900-SS-PK Installation Guide MANUAL DEL OPERADOR - DICKEY Tetrax GEO Steel control unit mdx61b0750-503-4-00 mdx61b - Banner Engineering TaqMan® Universal Master Mix II Protocol 1. Introduction 2. Installation CT241 Telephone Controller Copyright © All rights reserved.