Home

OM6040 User Guide, rev. 2.0

image

Contents

1. e li TE li 12 14 46 m lii Erst of Re List of FIJUTOS essen ee vii Propietar Noto teso acana Ix Trademarks ix Environmental Protection Statement ix Explanation of SymbolS x For MOTS ATOS CE Temperature and High Voltage Safety Instructions Xi Special Handling and Unpacking Instructions 2 2 2 2 4 General Instructions USage Year DIET xiii Unos c 1 3 TT ee e MR 1 3 Let N ee E eM 1 3 1 3 Technical Specification 1 5 GA Standards 1 7 18 PUDICAGUONS esercitano ea iaaa Ea AAS 1 8 2 Component Description 2 3 21 SION ee ee 2 3 2 2 Backplane EM nenne 2 8 2 2 MicroTCA Carrier Hub MCH nassen 2 10 Installation 3 3 3 3 3 2 ST e op 3 4 ID 1027 6427 Rev 2 0 Page iii Preface OM6040 3 3 III Cn JT a a a 3 5 ER MESURE 3 5 33 2 aem 3 5 n 3 5
2. This page has been intentionally left blank Page 1 2 ID 1027 6427 Rev 2 0 OM6040 Introduction 1 Introduction 1 1 Overview The OM6040 is a cost optimized compact and modular MicroTCA platform designed for the implementation of high performance MicroTCA solutions for industrial automation energy and medical applications The 6040 single tier MicroTCA Cube shelf consists of a MicroTCA backplane an power supply unit two cooling fans a Kontron Single Full size MicroTCA Carrier Hub MCH and four slots for accommodating up to four Single Full size AMC modules with various config urations of AMC CPUs and peripheral devices The components are enclosed in a chassis with a wall mount panel and two fixed feet allowing the OM6040 to either stand alone on any flat surface in development environments or be fix mounted using the wall mount panel The 6040 is closed with the exception of the front slots and cooling air inlets on the bottom and outlets on the top of the chassis The OM6040 is equipped with one large fan that provides forced air cooling for the front slots of the system and a second smaller fan that provides forced air cooling for the power supply and backplane in the rear area of the chassis OM6040 s outstanding features are e MicroTCA Cube design Support for up to four Single Full size AMCs Full size MCH with up to three tongues Integrated high power low cost AC
3. This document contains information proprietary to Kontron It may not be copied or transmitted by any means disclosed to others or stored in any retrieval system or media without the prior written consent of Kontron or one of its authorized agents Proprietary Note The information contained in this document is to the best of our knowledge entirely correct However Kontron cannot accept liability for any inaccuracies or the consequences thereof or for any liability arising from the use or application of any circuit product or example shown in this document Kontron reserves the right to change modify or improve this document or the product described herein as seen fit by Kontron without further notice Trademarks This document may include names company logos and trademarks which are registered trademarks and therefore proprietary to their respective owners Environmental Protection Statement This product has been manufactured to satisfy environmental protection requirements where possible Many of the components used structural parts printed circuit boards connectors batteries etc are capable of being recycled Final disposition of this product after its service life must be accomplished in accordance with applicable country state or local laws or regulations ID 1027 6427 Rev 2 0 Page ix Preface OM6040 Explanation of Symbols Caution Electric Shock This symbol and warn of hazards due
4. 3 5 Adding or Replacing OM6040 Components 3 6 3 6 MCH AMC Module Hot Swapping sss 3 6 3 7 AMC Connector Mating Cycles ae 3 6 Page iv ID 1027 6427 Rev 2 0 OM6040 Preface 1 1 1 2 1 3 3 1 List of Tables OM6040 Subrack Specifications 1 5 Standards ee E EE e a a 1 7 Related Publications ME 1 8 OM6040 Base Solution Configuration 3 3 ID 1027 6427 Rev 2 0 Page v Preface OM6040 This page has been intentionally left blank Page vi ID 1027 6427 Rev 2 0 OM6040 Preface List of Figures 1 1 OM6040 Shelf Perspective View 1 4 2 1 OM6040 Shelf Front View nase 2 3 2 2 6040 Shelf Rear View 2 4 2 2 OM6040 Shelf Bottom View ann 2 5 2 4 OM6040 Shelf Top View unse ade 2 5 2 5 OM6040 Shelf Left Side View 2 6 2 6 6040 Shelf Right Side View 2 6 2 7 6040 Shelf Dimensions 2 7 2 8 OM6040 Shelf Subrack View 2 8 2 9 Backplane Topology anne 2 9 ID 1027 6427 Rev 2 0 Page vii Preface OM6040 This page has been intentionally left blank Page viii ID 1027 6427 Rev 2 0 OM6040 Preface
5. EOS ESD safe work stations Where a safe work station is not guaranteed it is important for the user to be electrically discharged before touching the product with his her hands or tools This is most easily done by touching a metal part of your system housing It is particularly important to observe standard anti static precautions when changing piggy backs ROM devices jumper settings etc If the product contains batteries for RTC or memory backup ensure that the board is not placed on conductive surfaces including anti static plas tics or sponges They can cause short circuits and damage the batteries or conductive circuits on the board ID 1027 6427 Rev 2 0 Page xi Preface OM6040 General Instructions on Usage In order to maintain Kontron s product warranty this product must not be altered or modified in any way Changes or modifications to the device which are not explicitly approved by Kontron and described in this manual or received from Kontron s Technical Support as a special han dling instruction will void your warranty This device should only be installed in or connected to systems that fulfill all necessary techni cal and specific environmental requirements This applies also to the operational temperature range of the specific board version which must not be exceeded If batteries are present their temperature restrictions must be taken into account In performing all necessary installation and applicat
6. Single Full or Mid size AMC module to slot 4 allocated for Single Full or Mid size AMC module slot 5 allocated for MicroTCA Single Full size Carrier Hub MCH Two fans one located at bottom front area of the shelf and one in bottom of the rear bay Rear bay area occupied by the power supply unit CM and small fan Temperature Ranges Operating 0 C to 55 C Storage 40 C to 70 C Humidity 93 RH at 40 C non condensing Weight 2 8 kg shelf with fans and power supply unit 3 1kg as above plus Backplane and Compatibility Module MicroTCA compliant single tier backplane with Four AMC module connectors One three tongue MCH connector DC DC converters for 3 3 VDC management power PCle clock routing to all AMC slots Two connectors for interfacing to the MCH Compatibility Module CM Input power distribution and control functionality Fan power distribution Backplane FRU data EEPROM Fabrics Single star Gigabit Ethernet Fabric port 0 to each AMC slot port 1 to AMC slots 1 and 3 Fatpipes are routed in a star configuration between AMC ports 4 7 to the MCH Depending on the MCH configuration PCle switch or SRIO switch the fat pipes may be used for 4x lanes of PCle or 4x lanes of SRIO Fat pipes routing AMC ports 8 11 AMC slots 1 2 and 3 4 SATA SAS porting AMC Ports 2 and 3 AMC 1 port 2 to AMC 2 port 2 AMC 1 port 3 to AMC 3 port 2 AMC 3 port 3 to AMC 4
7. Specification v1 5 IPMI Platform Management FRU Information Storage Definition V1 0 Document Revision 1 1 September 27 1999 PCI Express PCI Express Base Specification Revision 1 0a Rapid IO Rapid 10 Specification Revision 1 3 Serial ATA Serial ATA 2 5 Specification All Kontron products Product Safety and Implementation Guide ID 1021 9142 1 8 ID 1027 6427 Rev 2 0 OM6040 Component Description Chapter Component Description ID 1027 6427 Rev 2 0 Page 2 1 Component Description OM6040 This page has been intentionally left blank Page 2 2 ID 1027 6427 Rev 2 0 OM6040 Component Description 2 Component Description 2 1 Shelf OM6040 is single tier vertically oriented MicroTCA Cube shelf and can accommodate up to four Single Mid size AMC For unused slots dummy filler assemblies must be installed to ensure proper air flow through the subrack If required these assemblies must be ordered separately as they are not standard elements of the OM6040 shelf The shelf s steel frame provides a robust housing for system components and airflow channel ization over the system slots It is wall mountable for industrial environments and it can be placed on any flat surface Always ensure that adequate spacing for proper cooling is provided The following figures illustrate the mechanical design of the OM6040 shelf Figure 2 1 OM6040 Shelf
8. following basic functions Fabric interconnectivity for Gigabit Ethernet SATA SAS PCle or SRIO depends on MCH used Input power distribution and control for payload and management power Point to point connectivity slot 1 2 and slot 3 4 ports 8 11 PCle clock distribution PMI monitor and control interfacing IPMB L Backplane FRU data storage EEPROM MCH IPMB 0 monitor and control interfacing Interfacing for MCH module The following figures illustrate the basic layout of the backplane and power supply In addition a block diagram of the backplane and the backplane topology are provided Figure 2 8 OM6040 Shelf Subrack View 4 y Y Fan 7 f 1019191919 9191919191911 9109117091011 1 1 10 1010 GV B Page2 8 ID 1027 6427 Rev 2 0 OM6040 Figure 2 9 Backplane Topology AMC1 AMC2 AMC3 AMC4 ID 1027 6427 Rev 2 0 Component Description Fabric to AMC Port 0 MCH Fabric A to AMC Port 1 AMC Port 2 SATA SAS AMC Port 3 SATA SAS Fat Pipes MCH Ports D G to AMC Ports 4 7 Clocks MCH CLK1 to AMC TCLKA Clocks MCH CLK3 to AMC TCLKA Clocks terminated AMC TCLKB to MCH CLK2 PRESENT ENABLE Backplane MCH Power Management 2 9 Component Description OM6040 The topology of the OM6040 backplane permits a wide range of module configurations There are however
9. or process in which the product was employed or any loss incurred as a result of the product not functioning at any given time are excluded The extent of Kontron liability to the customer shall not exceed the original purchase price of the item for which the claim exists Kontron issues no warranty or representation either explicit or implicit with respect to its products reliability fitness quality marketability or ability to fulfil any particular application or purpose As a result the products are sold as is and the responsibility to ensure their suitability for any given task remains that of the purchaser In no event will Kontron be liable for direct indirect or consequential damages resulting from the use of our hardware or software products or documentation even if Kontron were advised of the possibility of such claims prior to the purchase of the product or during any period since the date of its purchase Please remember that no Kontron employee dealer or agent is authorized to make any modi fication or addition to the above specified terms either verbally or in any other form written or electronically transmitted without the company s consent ID 1027 6427 Rev 2 0 Page xiii Preface OM6040 This page has been intentionally left blank Page xiv ID 1027 6427 Rev 2 0 OM6040 Introduction Chapter Introduction ID 1027 6427 Rev 2 0 Page 1 1 Introduction OM6040
10. port 2 IPMB L and interfacing supported for IPMI and local monitor and control ID 1027 6427 Rev 2 0 Page 1 5 Introduction OM6040 Table 1 1 OM6040 Subrack Specifications Continued FEATURES SPECIFICATIONS Fans Two auto restart brushless DC motors axial fans Input voltage range 10 to 14 VDC nominal 12 VDC Maximum air flow 170 m h and 13 5 m h Power consumption 5 3 and 1 6 watts Power Supply Unit Built in single AC power supply unit Input voltage range 85 to 264 VAC 47 to 63 Hz Output voltage 12 VDC Output power maximum continuous 250 watts forced air cooling required Maximum current rating 20 A Power derating 2 5 per degree from 50 C to 70 C ambient temperature 1 6 ID 1027 6427 Rev 2 0 OM6040 Introduction 1 4 Standards This Kontron MicroTCA Subrack complies with the requirements of the following standards Table 1 2 Standards COMPLIANCE TYPE STANDARD TEST LEVEL CE Emission EN55022 EN61000 6 3 Immission EN55024 EN61000 6 2 Electrical Safety EN60950 1 Mechanical Mechanical Dimensions IEEE 1101 10 Environmental and Climatic Humidity IEC60068 2 78 93 RH at 40 C non condensing Health Aspects WEEE Directive 2002 96 EC Waste electrical and electronic equipment RoHS Directive 2002 95 EC Restriction of the use of certain hazardous substances in electrical and electronic equipment Note K
11. safety and of the correct operation of your new Kontron product you are requested to conform with the following guidelines For Your Safety Temperature and High Voltage Safety Instructions Warning All operations on this device must be carried out by sufficiently skilled personnel only Be careful this device will heat up during operation and if touched may cause burns The temperature of the product housing may reach up to approximately 50 C Allow for sufficient cool down before han dling after power is turned off Caution Electric Shock Before installing your new Kontron product into a system always ensure that your mains power is switched off This applies also to the installation of piggybacks Serious electrical shock hazards can exist during all installation repair and maintenance operations with this product Therefore always unplug the power cable and any other cables which provide external voltages before performing work Special Handling and Unpacking Instructions ESD Sensitive Device Electronic boards and their components are sensitive to static elec tricity Therefore care must be taken during all handling operations and inspections of this product in order to ensure product integrity at all times Do not handle this product out of its protective enclosure while it is not used for operational pur poses unless it is otherwise protected Whenever possible unpack or pack this product only at
12. some restrictions as to the use of particular module combinations If for example CPU modules are installed in both slots 1 and 2 or 3 and 4 there must be no SATA functionality active on AMC ports 2 and 3 If both CPUs have SATA active on these ports neither of the CPUs will not properly boot If PCle functionality is implemented by default slot 1 is configured as the root complex This can be changed by setting appropriate PCle configuration parameters in the MCH 2 3 MicroTCA Carrier Hub MCH The OM6040 is supplied with an appropriate MCH installed at the factory There are three pos sible configrations which must be specified at the time the OM6040 is ordered There is a base MCH which supports only GbE Fabric the second version supports GbE and PCle and the third version provides GbE and SRIO Page 2 10 ID 1027 6427 Rev 2 0 OM6040 Installation Chapter Installation ID 1027 6427 Rev 2 0 Page 3 1 Installation OM6040 This page has been intentionally left blank Page 3 2 ID 1027 6427 Rev 2 0 OM6040 Installation 3 Installation 3 1 General The OM6040 shelf itself is an application support platform for MicroTCA solutions In order to satisfy solution requirements it must be configured accordingly To assist application devel opers and system implementers in achieving their goals the OM6040 is provided with a mini mum configuration Specifically it is de
13. Front View SLOTS SLOT IMCISISISISISISISIS Peel 16816181 eee else gt 4901 H 5 ID 1027 6427 Rev 2 0 Page 2 Component Description OM6040 Figure 2 2 OM6040 Shelf Rear View Vor Netzstecker ziehen 400 240V 50 60 Hz Main Power Switch Input Power Connector Page 2 4 ID 1027 6427 Rev 2 0 OM6040 Component Description Figure 2 3 OM6040 Shelf Bottom View nem 19161519 17157 90 OGO 5121719 bl LEE ID 1027 6427 Rev 2 0 2 5 Component Description OM6040 Figure 2 5 OM6040 Shelf Left Side View Figure 2 6 OM6040 Shelf Right Side View ID 1027 6427 Rev 2 0 OM6040 Component Description Figure 2 7 OM6040 Shelf Dimensions 5 250 00 u 6 aon eee 872 So EEE TETTE 11 25 CEE 00 50 a N _ 157 00 E 90000000000000000000000000000 S 00000000000000900000000000000 60 P ID 1027 6427 Rev 2 0 Page 2 7 Component Description OM6040 2 2 Backplane and CM The OM6040 backplane and CM MCH Compatibility Module provide the
14. G kontron User Guide OM6040 MicroTCA Four Slot Single Width Full Size Single Tier Cube Shelf Doc ID 1027 6427 Rev 2 0 December 10 2010 If its embedded it s Kontron Preface OM6040 Revision History Publication Title OM6040 MicroTCA Four Slot Single Width Single Tier Cube Shelf User Guide 1027 6427 Rev Brief Description of Changes Date of Issue 1 0 Initial issue 19 Jan 2009 2 0 Updated to reflect extensive system modifications 10 Dec 2010 Imprint Kontron Modular Computers GmbH may be contacted via the following MAILING ADDRESS TELEPHONE AND E MAIL Kontron Modular Computers GmbH 49 0 800 SALESKONTRON Sudetenstrake 7 sales kontron com D 87600 Kaufbeuren Germany For information about other Kontron products please visit our Internet web site www kontron com Disclaimer Copyright 2009 2010 Kontron AG All rights reserved All data is for information purposes only and not guaranteed for legal purposes Information has been carefully checked and is be lieved to be accurate however no responsibility is assumed for inaccuracies Kontron and the Kontron logo and all other trademarks or registered trademarks are the property of their respec tive owners and are recognized Specifications are subject to change without notice Page ii ID 1027 6427 Rev 2 0 OM6040 Preface Table of Contents Ac li IMPAN E
15. e system Page 3 6 ID 1027 6427 Rev 2 0
16. ion operations please follow only the in structions supplied by the present manual Keep all the original packaging material for future storage or warranty shipments If it is neces sary to store or ship the board please re pack it as nearly as possible in the manner in which it was delivered Special care is necessary when handling or unpacking the product Please consult the special handling and unpacking instruction on the previous page of this manual Page xii ID 1027 6427 Rev 2 0 OM6040 Preface Kontron grants the original purchaser of Kontron s products a TWO YEAR LIMITED HARDWARE WARRANTY as described in the following However no other warranties that may be granted or implied by anyone on behalf of Kontron are valid unless the consumer has the express written consent of Kontron Two Year Warranty Kontron warrants their own products excluding software to be free from manufacturing and material defects for a period of 24 consecutive months from the date of purchase This warranty is not transferable nor extendible to cover any other users or long term storage of the product It does not cover products which have been modified altered or repaired by any other party than Kontron or their authorized agents Furthermore any product which has been or is suspected of being damaged as a result of negligence improper use incorrect handling servicing or maintenance or which has been damaged as a result of excessive curre
17. livered with an appropriate MCH module The following table and figures illustrate the base solution configuration of the OM6040 This configuration is the basis for the information and procedures provided in the following Installa tion sections Table 3 1 OM6040 Base Solution Configuration COMPONENT QTY SYSTEM LOCATION DESCRIPTION Subrack 1 Mechanical chassis of OM6040 Backplane 1 Power Supply Unit PSU 1 Built in to the rear bay area Fan 2 fan in the bottom front bay area and one fan in the rear bay area Filler Panels 0 Must be ordered separately as required Available are 2HP filler panels and Full size dummies MCH 1 FSA 5 Single Full size with extraction handle Required configuration must be specified at time OM6040 is ordered Legend for Table 3 1 FSA front slot area as seen from front numbered left to right QTY quantity ID 1027 6427 Rev 2 0 Page 3 3 Installation OM6040 3 2 Safety The following precautions must be observed Caution Electric Shock Hazard The OM6040 requires AC mains power in the range from 90 to 240 volts for operation Therefore due caution must be exercised when handling or per forming operations on the OM6040 when power is applied Failure to comply with the above could endanger your life or health and may cause damage to the OM6040 or other system components including pro cess side signal conditioning equipment ESD Equi
18. nt voltage or temperature or which has had its serial number s any other markings or parts thereof altered defaced or removed will also be excluded from this warranty If the customer s eligibility for warranty has not been voided in the event of any claim he may return the product at the earliest possible convenience to the original place of purchase together with a copy of the original document of purchase a full description of the application the product is used on and a description of the defect Pack the product in such a way as to ensure safe transportation see our safety instructions Kontron provides for repair or replacement of any part assembly or sub assembly at their own discretion or to refund the original cost of purchase if appropriate In the event of repair refunding or replacement of any part the ownership of the removed or replaced parts reverts to Kontron and the remaining part of the original guarantee or any new guarantee to cover the repaired or replaced items will be transferred to cover the new or repaired items Any extensions to the original guarantee are considered gestures of goodwill and will be defined in the Repair Report issued by Kontron with the repaired or replaced item Kontron will not accept liability for any further claims resulting directly or indirectly from any warranty claim other than the above specified repair replacement or refunding In particular all claims for damage to any system
19. of or damage to the OM6040 3 3 2 Filler Panels Filler panels for the OM6040 are available as required Depending on solution requirements these components may be removed or reconfigured as necessary 3 4 Mounting The OM6040 is supplied with a fixed mounting panel for installation in a system cabinet This will require mounting hardware which is not supplied with the OM6040 For operation of the OM6040 on a flat surface desktop or rack shelf there are no special mounting fixtures In this case for operation ensure adequate airflow to the OM6040 Care must also be taken to ensure that the OM6040 cannot fall off of the flat surface ID 1027 6427 Rev 2 0 Page 3 5 Installation OM6040 3 5 Adding or Replacing OM6040 Components Solution requirements determine the operational configuration of the OM6040 Therefore it may or will be necessary to add remove or reconfigure components Warning Remove power from the system before performing any reconfiguration of these components Failure to comply with the above could endanger your life or health and may cause damage to the OM6040 or other system components including pro cess side signal conditioning equipment Kontron rejects any and all liability for damage resulting from failure to remove power before performing the above AMC modules are normally supplied with documentation which provides instructions or guide lines on their installation or replacement Please refe
20. ontron performs comprehensive environmental testing of its products in accor dance with applicable standards Customers desiring to perform further environmental testing of Kontron prod ucts must contact Kontron for assistance prior to performing any such testing This is necessary as it is possible that environmental testing can be destructive when not performed in accordance with the applicable specifications In particular for example boards without conformal coating must not be exposed to a change of temperature exceeding 1K minute averaged over a period of not more than five minutes Otherwise condensation may cause irre versible damage especially when the board is powered up again Kontron does not accept any responsibility for damage to products resulting from destructive environmental testing ID 1027 6427 Rev 2 0 Page 1 7 Introduction OM6040 1 5 Related Publications The following publications contain information relating to this product Table 1 3 Related Publications PRODUCT PUBLICATION MicroTCA PICMG 0 Micro Telecommunications Computing Architecture R1 0 July 6 2006 AMC PICMG AMC 0 Advanced Mezzanine Card Specification R2 0 Nov 15 2006 PICMG AMC 1 PCI Express R2 0 Oct 8 2008 PICMG AMC 2 Gigabit Ethernet R1 0 PICMG AMC 3 Storage Interfaces R1 0 Aug 25 2005 PICMG AMC 4 Serial Rapid 10 R1 0 July 11 2009 IPMI Intelligent Platform Management Interface
21. pment The OM6040 contains electrostatic sensitive devices Ensure that the follow ing precautions are observed to avoid damaging the OM6040 Discharge clothing before touching the assembly Tools must also be dis charged before use Do not touch any board components connector pins or board conductive cir cuits If working at an anti static workbench with professional discharging equip ment ensure compliance with its usage when handling this product Page 3 4 ID 1027 6427 Rev 2 0 OM6040 Installation 3 3 Prerequisites 3 3 1 Cooling The OM6040 requires forced air cooling which is provided by the cooling fans located on the bottom side of the subrack in the front and rear bay areas Adequate ambient airflow to the fan inlet areas must be ensured In addition the area above the subrack must also provide for ad equate outlet airflow Direct re cycling of outlet air to the inlet area must be avoided to preclude overheating of the system Warning Failure to comply with the above can result in improper operation or damage to the OM6040 or other components installed in the OM6040 Kontron rejects any and all liability for damage resulting from inadequate cooling of the OM6040 or components installed in the OM6040 Warning If the OM6040 is operated at temperatures above 45 C ensure that an inlet area and an outlet area of 1U 44 45 mm are provided Failure to comply with the above may cause improper operation
22. power supply unit instead of high cost power mod ules Two integrated cooling fans e MicroTCA backplane Four Single Full size AMC module slots One three tongue Full size slot Fabric support Gigabit Ethernet PCI Express Serial Rapid I O SATA SAS Integrated generation of 3 3 VDC management power e Payload power switching on mezzanine compatiblilty module Storage for FRU data 1 2 Components The OM6040 shelf is comprised of the following elements Chassis Backplane with CM integrated Subrack Power Supply Unit PSU Fans MCH Kontron AM490n ID 1027 6427 Rev 2 0 Page 1 3 Introduction OM6040 The following figure illustrates the OM6040 shelf configured with the 4901 MCH The chas sis is provided with a wall mount panel on the left side of the chassis The cooling fans are lo cated at the bottom of the chassis and the power supply at the rear These units are not user serviceable Figure 1 1 OM6040 Shelf Perspective View Mounting Holes 1 1 AMC2 AMC3 AMC4 SLOT SLOT SLOT SLOT Page 1 4 ID 1027 6427 Rev 2 0 OM6040 Introduction 1 3 Technical Specification Table 1 1 M6040 Subrack Specifications FEATURES SPECIFICATIONS Shelf MicroTCA cube form designed for Single Full size AMC Modules Dimensions 250mm x 157mm x 150mm depth x width x height with mounting panel Slot geometry from left side of the subrack slot 1 allocated for
23. r to their respective documentation for fur ther assistance For replacement of the MCH refer to the MCH User Guide The power supply fans and backplane are not user replaceable 3 6 MCH AMC Module Hot Swapping 6040 as such is designed to support hot swapping under IPMI control Hot swapping however is a function of the individual application requirements and the ability of system com ponents hardware and software to support these requirements Therefore it is the responsi bility of the system integrator to ensure the system operability and compliance with hot swap requirements prior to application implementation More specifically for example the MCH used supports hot swapping of itself This in return re sults effectively in a power off and on cycling of the system as a whole If this is not desired then precautions must be taken to ensure proper hot swapping of system components 3 7 AMC Connector Mating Cycles The OM6040 backplane connectors and the AMC module card edge connectors are designed to support at least 200 insertion extraction cycles As systems used in a laboratory or develop ment environment may exceed this number of mating cycles over the product life time the card edge connector of each AMC module should be inspected for wear or damage before in sertion or after extraction If a card edge connector exhibits excessive wear or damage the AMC module must be replaced to preclude improper operation of th
24. to electrical shocks gt 60V when touching products or parts of them Failure to observe the pre cautions indicated and or prescribed by the law may endanger your life health and or result in damage to your material Please refer also to the section High Voltage Safety Instructions on the following page Warning ESD Sensitive Device This symbol and title inform that electronic boards and their compo nents are sensitive to static electricity Therefore care must be taken during all handling operations and inspections of this product in order to ensure product integrity at all times Please read also the section Special Handling and Unpacking Instructions on the following page Warning This symbol and title emphasize points which if not fully understood and taken into consideration by the reader may endanger your health and or result in damage to your material Note This symbol and title emphasize aspects the reader should read through carefully for his or her own advantage oe Page x ID 1027 6427 Rev 2 0 OM6040 Preface Your new Kontron product was developed and tested carefully to provide all features neces sary to ensure its compliance with electrical safety requirements It was also designed for a long fault free life However the life expectancy of your product can be drastically reduced by improper treatment during unpacking and installation Therefore in the interest of your own

Download Pdf Manuals

image

Related Search

Related Contents

Intel DX79TO  NXドライバ ツールユニット取扱説明書  Uniden EcoTerra GMR2889-2CK User's Manual  Brainboxes PCMCIA 9-pin RS232  DS 1400E Bedienungsanweisung  3Com 6000 Switch User Manual  Getting started    取 扱 説 明 書 - リズム時計工業株式会社  Bedienungsanleitung  

Copyright © All rights reserved.
Failed to retrieve file