Contents

1. 49 7836 50 201 77761 Schiltach E mail info de vega com Germany www vega com
2. system VEGA Connection technology Connection procedure 4 Connecting to the bus system 4 1 Connecting The voltage supply and signal output are connected via the spring loaded terminals in the housing Connection to the display and adjustment module or to the interface adapter is carried out via contact pins in the housing Information The terminal block is pluggable and can be removed from the electronics To do this lift the terminal block with a small screwdriver and pull it out When reinserting the terminal block you should hear it snap in Proceed as follows 1 Unscrew the housing cover 2 Ifa display and adjustment module is installed remove it by turn ing it slightly to the left 3 Loosen compression nut of the cable entry gland 4 Remove approx 10 cm 4 in of the cable mantle strip approx 1 cm 0 4 in of insulation from the ends of the individual wires 5 Insert the cable into the sensor through the cable entry Fig 3 Connection steps 5 and 6 Single chamber housing VEGABAR 86 Foundation Fieldbus LO807l N3 E2E9r 46323 EN 140801 4 Connecting to the bus system Fig 4 Connection steps 5 and 6 Double chamber housing 6 Insert the wire ends into the terminals according to the wiring plan Information Solid cores as well as flexible cores with wire end sleeves are insert ed directly into the terminal openings In case of flexible cores w
3. to the non Ex as well as to the Ex ia version Fig 6 Electronics compartment double chamber housing 1 Internal connection to the terminal compartment 2 Contact pins for the display and adjustment module or interface adapter 3 Simulation switch 1 mode for simulation release 10 VEGABAR 86 Foundation Fieldbus LO807l N3 E2E9r 46323 EN 140801 VEGA 4 Connecting to the bus system Terminal compartment Fig 7 Terminal compartment double chamber housing 1 Voltage supply signal output 2 For display and adjustment module or interface adapter 3 For external display and adjustment unit 4 Ground terminal for connection of the cable screen Information Parallel use of an external display and adjustment unit and a display and adjustment module in the terminal compartment is not supported VEGABAR 86 Foundation Fieldbus 11 5 Set up with the display and adjustment module VEGA 5 Set up with the display and adjustment module 5 1 Insert display and adjustment module The display and adjustment module can be inserted into the sensor and removed again at any time You can choose any one of four differ ent positions each displaced by 90 It is not necessary to interrupt the power supply Proceed as follows 1 Unscrew the housing cover 2 Place the display and adjustment module on the electronics in the desired
4. Quick setup guide Submersible pressure transmitter with ceramic measuring cell VEGABAR 86 Foundation Fieldbus li Document ID 46323 Contents VEGA Contents 1 For your safety Tl Authorised personnel iii csccensecises acd hv aroari iannis 3 ee 3 1 3 Warning about inCOrmect USC iiss ici sscsisiccaeccsesess send sex sessesces sve cuss sossatavsrcsete sess cate rst EEan ETAN 3 1 4 General safety instructions SEE GO 3 1 6 PermissibleprocessjpressUr sa 3 1 7 NAMUR recommendations 1 8 Environmental instructions 2 Product description ee 5 3 Mounting 3 1 General instructions for use of the instrument pp 7 3 2 Ventilation and pressure compensatig pp 7 4 Connecting to the bus system 4 E CoAT eao E A EE A E AA EN AA A AE 4 2 Single chamber housing 4 3 Double chamber HOUSING ass sa 5 Set up with the display and adjustment module 5 1 Insert display and adjustment module ee 12 5 2 Parameter adjustment QUICK StU niina aaia 13 5 3 Parameter adjustment Extended adjustment ee 14 6 Supplement GA TECHMIGAl Gata ssns eree rrera ra aE r AE UEA EVEEN AS EErEE SANET EEEE EEE 17 Information This quick setup guide enables quick setup and commissioning of your instrument You can find supplementary information in the corresponding more detailed Operating Instructions Manual as well as the Safety Manual that comes with instruments with SIL qualification These man
5. d IP 66 IP 68 0 2 bar Cable entry M20x 1 5 1 x cable gland M20 x 1 5 cable 6 12 mm 1 x blind plug M20 x 1 5 Ye NPT 1 x blind plug NPT 1 x closing cap red NPT Wire cross section spring loaded terminals Massive wire stranded wire 0 2 2 5 mm AWG 24 14 Stranded wire with end sleeve 0 2 1 5 mm AWG 24 16 Voltage supply Operating voltage Non Ex instrument 9 32VDC Ex ia instrument Power supply 9 17 5V DC FISCO model Ex ia instrument Power supply 9 24VDC ENTITY model Ex d instrument 14 32VDC Operating voltage U illuminated display and adjustment module Non Ex instrument 13 5 32V DC Ex ia instrument Power supply 13 5 17 5V DC FISCO model Ex ia instrument Power supply 13 5 24V DC ENTITY model Power supply by max number of sensors Fieldbus max 32 max 10 with Ex VEGABAR 86 Foundation Fieldbus 17 Notes 18 VEGABAR 86 Foundation Fieldbus LO8071 N3 EcE9r 46323 EN 140801 Notes VEGABAR 86 Foundation Fieldbus 19 Printing date VEGA All statements concerning scope of delivery application practical use and operat ing conditions of the sensors and processing systems correspond to the information available at the time of printing Subject to change without prior notice 46323 EN 140801 VEGA Grieshaber KG Schiltach Germany 2014 VEGA Grieshaber KG Phone 49 7836 50 0 Am Hohenstein 113 Fax
6. easurement 2 Units In this menu item you determine the adjustment and temperature units of the instrument Depending on the selected application in the menu item Application different adjustment units are available VEGABAR 86 Foundation Fieldbus 13 5 Set up with the display and adjustment module VEGA Quick setup Process pressure measurement Quick setup Level meas urement Measurement loop name Slave for electronic Units of measurement differential pressure Sensor Disabled Temperature unit Application 3 Position correction In this menu item you compensate the influence of the installation position of the instrument offset on the measured value 4 Zero adjustment In this menu item you carry out the zero adjustment for the processs pressure Enter the corresponding pressure value for 0 5 Span adjustment In this menu item you carry out the span adjustment for the processs pressure Enter the corresponding pressure value for 100 Sensor mounting correction Zero Span P Offset 0 00 x amp 100 007 a 0 0003 bar W 0 0000bar 1 0000bar amp 0 0001 bar 0 0000 bar 0 0000 bar 3 Position correction In this menu item you compensate the influence of the installation position of the instrument offset on the measured value 4 Max adjustment In this menu item you carry out the max adjustment for level Enter the percentage value and the corresponding value for the
7. ecom mendations e NE 21 Electromagnetic compatibility of equipment e NE 53 Compatibility of field devices and display adjustment components e NE 107 Self monitoring and diagnosis of field devices For further information see www namur de 1 8 Environmental instructions Protection of the environment is one of our most important duties That is why we have introduced an environment management system with the goal of continuously improving company environmental pro tection The environment management system is certified according to DIN EN ISO 14001 Please help us fulfill this obligation by observing the environmental instructions in this manual e Chapter Packaging transport and storage e Chapter Disposal VEGABAR 86 Foundation Fieldbus LO807l N3 E2E9r 46323 EN 140801 VEGA 2 Product description Type label Serial number Instru ment search 2 Product description 2 1 Configuration The type label contains the most important data for identification and use of the instrument VEGABARS2 M B82 AXDASAGGSHXKIMXX OmA HART iwo wire ART ection 166 67 NEMA 4X 1000kPa manual r 100 6000kP a s n 25819869 VEGA 77761 Schi tach Germany Www vega com Fig 1 Layout of the type label example Instrument type Product code Field for approvals Power supply and signal output electronics Protection rating Measuring range Permissible process pressu
8. ed one after the other and provided with the correct parameters If possible go through the items in the given sequence The procedure is described below The following submenu points are available Measurement loop name Application t Units ent Sensor mounting correction Adjustment Measurenent loop nane The submenu points described below Menu overview Menu item Parameter Application Process pressure Level Activation Deactivation Slave for elec tronic differential pressure Units Unit of measurement Temperature unit Position correction Adjustment Zero Min adjustment Span Max adjustment Damping Integration time Linearization Linearization type Lock adjustment VEGABAR 86 Foundation Fieldbus 15 5 Set up with the display and adjustment module Display Diagnostics Additional adjustments Menu item Menu language Displayed value 1 Displayed value 2 Backlight Menu item Parameter Sensor status Peak value indicator Pressure Temperature Simulation Menu item Parameter PIN Date Time Copy instrument settings Special parameters Scaling Scaling size Scaling format 16 VEGABAR 86 Foundation Fieldbus LO807l N3 E2E9r 46323 EN 140801 VEGA 6 Supplement 6 Supplement 6 1 Technical data Electromechanical data version IP 66 IP 67 an
9. he country specific installation standards as well as all prevailing safety regulations and accident prevention rules The instrument must only be operated in a technically flawless and reliable condition The operator is responsible for trouble free opera tion of the instrument During the entire duration of use the user is obliged to determine the compliance of the necessary occupational safety measures with the current valid rules and regulations and also take note of new regula tions 1 5 CE conformity The device fulfills the legal requirements of the applicable EC guide lines By affixing the CE marking we confirm successful testing of the product You can find the CE Certificate of Conformity in the download section of our homepage 1 6 Permissible process pressure The permissible process pressure is specified on the type label with Process pressure see chapter Configuration For safety reasons VEGABAR 86 Foundation Fieldbus 3 1 For your safety VEGA this range may not be exceeded This applies even if a measuring cell with a measuring range order related higher than the permissible pressure range of the process fitting is installed 1 7 NAMUR recommendations NAMUR is the automation technology user association in the process industry in Germany The published NAMUR recommendations are accepted as the standard in field instrumentation The device fulfills the requirements of the following NAMUR r
10. ithout end sleeves press the terminal from above with a small screwdriver the terminal opening is then free When the screwdriver is released the terminal closes again You can find further information on the max wire cross section under Technical data Electromechanical data 7 Check the hold of the wires in the terminals by lightly pulling on them 8 Connect the screen to the internal ground terminal connect the outer ground terminal to potential equalisation 9 Tighten the compression nut of the cable entry gland The seal ring must completely encircle the cable 10 Reinsert the display and adjustment module if one was installed 11 Screw the housing cover back on The electrical connection is finished 4 2 Single chamber housing The following illustration applies to the non Ex Ex ia and Ex d ver sion VEGABAR 86 Foundation Fieldbus 9 4 Connecting to the bus system Electronics and terminal compartment Electronics compartment 2 3 J Bus 4 wl Re Ors Fig 5 Electronics and terminal compartment single chamber housing Voltage supply signal output Contact pins for the display and adjustment module or interface adapter Simulation switch 1 mode for simulation release For external display and adjustment unit Ground terminal for connection of the cable screen QAROM 4 3 Double chamber housing The following illustrations apply
11. max level 5 Min adjustment In this menu item you carry out the min adjustment for level Enter the percentage value and the corresponding value for the min level Sensor mounting correction Min adjustment Max adjustment Offset 2 0 00 100 00 0 0003 bar W 0 0500 bar 1 0000 bar 0 0001 bar 0 0000 bar 0 0001 bar The quick setup is finished 5 3 Parameter adjustment Extended adjustment For technically demanding measuring points you can carry out extended settings in Extended adjustment Quick setup Extended adjustment 14 VEGABAR 86 Foundation Fieldbus LO807 N3 E2E9r 46323 EN 140801 VEGA Main menu Setup 5 Set up with the display and adjustment module je The main menu is divided into five sections with the following func tions Display Diagnostics Additional adjustments Info Setup Settings e g for measurement loop name application units position correction adjustment signal output Display Settings e g for language measured value display lighting Diagnosis Information e g on instrument status pointer measure ment reliability simulation Additional adjustments PIN date time reset copy function Info Instrument name hardware and software version date of manu facture device ID sensor features Note For optimum adjustment of the measuring point the individual sub menu items in the main menu item Setup should be select
12. position and turn it to the right until it snaps in 3 Screw housing cover with inspection window tightly back on Disassembly is carried out in reverse order The display and adjustment module is powered by the sensor an ad ditional connection is not necessary Fig 8 Installing the display and adjustment module in the electronics compart ment of the single chamber housing 12 VEGABAR 86 Foundation Fieldbus LO807l N3 E2E9r 46323 EN 140801 5 Set up with the display and adjustment module bale Quick setup Presettings Fig 9 Installing the display and adjustment module in the double chamber housing 7 Inthe electronics compartment 2 Inthe terminal compartment Note If you intend to retrofit the instrument with a display and adjustment module for continuous measured value indication a higher cover with an inspection glass is required 5 2 Parameter adjustment Quick setup To quickly and easily adapt the sensor to the application select the menu item Quick setup in the start graphic on the display and adjustment module Quick setup Extended adjustment Carry out the following steps in the below sequence You can find Extended adjustment in the next sub chapter 1 Application In this menu item you activate deactivate the slave for the electronic differential pressure and select the application The application com prises process pressure and level m
13. re Material wetted parts Hardware and software version 10 Order number 77 Serial number of the instrument 72 Data Matrix Code for Smartphone App 13 Symbol of the device protection class 14 ID numbers instrument documentation 15 Reminder to observe the instrument documentation 16 Notified authority for CE marking 17 Approval directive OANA ARKRWNH The type label contains the serial number of the instrument With it you can find the following instrument data on our homepage e Product code HTML e Delivery date HTML e Order specific instrument features HTML e Operating instructions and quick setup guide at the time of ship ment PDF Order specific sensor data for an electronics exchange XML e Test certificate PDF optional Go to www vega com VEGA Tools and nstrument search Enter the serial number Alternatively you can access the data via your smartphone VEGABAR 86 Foundation Fieldbus 5 2 Product description VEGA e Download the smartphone app VEGA Tools from the Apple App Store or the Google Play Store e Scan the Data Matrix code on the type label of the instrument or e Enter the serial number manually in the app VEGABAR 86 Foundation Fieldbus LO807l N3 E2E9r 46323 EN 140801 VEGA 3 Mounting Protection against mois ture Instruments in non Ex and Ex ia version 3 Mounting 3 1 General instructions for use of the instrument Protect your in
14. strument against moisture ingress through the following measures e Use the recommended cable see chapter Connecting to power supply e Tighten the cable gland e When mounting horizontally turn the housing so that the cable gland points downward e Loop the connection cable downward in front of the cable gland This applies particularly to e Outdoor mounting e Installations in areas where high humidity is expected e g through cleaning processes e Installations on cooled or heated vessels 3 2 Ventilation and pressure compensation The filter element is mounted into the electronics housing It has the following functions e Ventilation of the electronics housing e Atmospheric pressure compensation with relative pressure meas uring ranges Turn the housing so that the filter element points downward after the instrument is installed This provides better protection against buildup Fig 2 Position of the filter element non Ex Ex ia version Housing plastic stainless steel precision casting Housing aluminium Housing stainless steel electropolished Filter element KOM With the following instruments a blind plug is installed instead of the filter element e Instruments in protection IP 66 IP 68 1 bar ventilation via capil laries in non detachable cable e Instruments with absolute pressure VEGABAR 86 Foundation Fieldbus T7 4 Connecting to the bus
15. uals are available on the supplied DVD or in the download area of www vega com Operating instructions VEGABAR 86 Foundation Fieldbus Document ID 45043 Editing status of the quick setup guide 2014 07 30 2 VEGABAR 86 Foundation Fieldbus LO807l N3 E2E9r 46323 EN 140801 1 For your safety 1 For your safety 1 1 Authorised personnel All operations described in this operating instructions manual must be carried out only by trained specialist personnel authorised by the plant operator During work on and with the device the required personal protective equipment must always be worn 1 2 Appropriate use Model VEGABAR 86 is a pressure transmitter for level and gauge measurement You can find detailed information about the area of application in chapter Product description Operational reliability is ensured only if the instrument is properly used according to the specifications in the operating instructions manual as well as possible supplementary instructions 1 3 Warning about incorrect use Inappropriate or incorrect use of the instrument can give rise to application specific hazards e g vessel overfill or damage to system components through incorrect mounting or adjustment 1 4 General safety instructions This is a high tech instrument requiring the strict observance of stand ard regulations and guidelines The user must take note of the safety instructions in this operating instructions manual t