Home
Installation and operating instructions: Radio-control light
Contents
1. OSRAM amp Installation and operating instructions Radio control light sensor patD Type DALI LS ADVANCED y 4 A OSRAM GmbH Hellabrunner Str 1 D 81536 Munich Tel 49 0 89 6213 0 Fax 49 0 89 6213 2020 Customer Service Center KSC Germany Albert Schweitzer Str 64 D 81735 Munich Tel 49 0 1803 677 200 Fax 49 0 1803 677 202 www osram com OSRAM Contents 1 Function overview Page 3 2 Activating the sensor inserting the batteries Page 3 3 Programming in the ADVANCED central unit Page 4 4 MSA AO se een Page 5 5 Lighting control setpoint adjustment Page 6 6 Notes on radio operation cccceeeeeeeeeeeeeeeeeeeeeeeeeees Page 7 7 Technical data BAPAUHBERERRRURRNDEFRREREEBEPEREELTPEREREOEUEFEEPECEREREBEEENG Page 8 Page 2 Installation instructions Light Sensor DALI LS ADVANCED OSRAM amp 1 Function overview The radio control light sensor transmits brightness values to the DALI central unit in a DALI ADVANCED lighting control system How often the sensor sends the values will depend on how often the brightness in the detection area changes The sensor detects the luminance in a particular detection area and forwards this brightness value actual value to the central unit This actual value is compared with the setpoint value stored in the central unit The central unit then uses this comparison to contr
2. d and the lighting value set manually is retained The same applies when a lighting scene involving the regulated group is selected To restart lighting control you need to switch the group off and on again using an appropriate trained channel button Page 6 Installation instructions Light Sensor DALI LS ADVANCED OSRAM 6 Notes on radio operation A non exclusive transmission path is used for radio transmission which means that interference cannot be ruled out Radio transmission is not suitable for safety applications such as emergency shutdown or calls to the emergency services The range of a transmitter up to 100 m in the open depends on the nature of the building Dry material Penetration Wood plaster plasterboard approx 90 Brick MDF approx 70 Reinforced concrete approx 30 Metal metal grating aluminium approx 10 cladding OSRAM CE 0700 Notes on radio operation This radio system may only be connected to other communication networks if this does not infringe the relevant national laws This radio system may not be used for communicating beyond property boundaries If operated in Germany the regulations contained in Official Bulletin Vfg 73 2000 must be met If used as specified this device complies with the requirements of the R amp TTE directive 1999 5 EU A complete conformity declaration can be found on the internet at www osram com The light sen
3. l unit as the setpoint for lighting control Changing the setpoint TIN Select Regulation in the Lighting Control menu on the manual programming unit Enter the number of the group to be controlled You can now change the setpoint Adjust the lighting to the required setting and select Change Setpoint The message waiting for brightness value will appear The next brightness value that the light sensor sends is stored as the new setpoint in the central unit Setpoint changed This process may take up to 90 seconds Activate lighting control by switching the Regulation option to ON Note As long as there is a radio link between the MPU and the central unit lighting regulation will not be carried out Lighting control Lighting control is active if the relevant group has been switched on because a trained channel button on a wall mounted or hand held transmitter has been pressed short press The lighting system is switched to 100 and the brightness is then adjusted to the setpoint stored in the central unit If the measured brightness value exceeds the current brightness setpoint at the minimum dimmer setting for the luminaires the relevant group is automatically switched off The lighting system is not automatically switched on again Terminating control If the regulated group is adjusted faded up or down using trained channel buttons on a wall mounted or hand held transmitter lighting control is terminate
4. light sensor clockwise through no more than 45 on Abb E the base plate until it clicks into place jJ A rN To improve radio transmission you can thread the antenna out of the casing To do this puncture the antenna opening Fig E2 carefully with a screwdriver and push the antenna through the hole before installing the base plate Do not strip the antenna or shorten it Installation instructions Light Sensor DALI LS ADVANCED Page 5 OSRAM 5 Lighting control setpoint adjustment As already mentioned a group is assigned to the light sensor when it is trained in the ADVANCED central unit The luminaires of this group will then be controlled by the sensor This group must also be assigned at least one channel button on a wall mounted or hand held transmitter for operating the lighting controls Train the relevant channel button using the manual programming unit and then assign this button to the group to be controlled control of group XX gt see operating instructions for the manual programming unit Setting the brightness setpoint Abb F The luminance measured on the light sensor Fig F2 A Ld N comprises the reflected artificial light Fig F1 and i ze daylight Fig F3 and depends on the reflective properties of the surface Fig F4 It is transmitted as a brightness value at regular intervals to the central unit for evaluation If the setpoint is changed this brightness value is stored in the centra
5. ol the lighting The light sensor consists of the following Base plate Brightness sensor LED Abb A 2 Activating the sensor inserting the batteries Battery type The light sensor is operated with a lithium button cell type CR 2450N The battery is included with the sensor To avoid damaging the electronics through electrostatic discharge you must comply with the safety precautions for electrostatically sensitive devices when changing the battery Inserting replacing the battery Abb B 1 Detach the light sensor from the base plate by turning the unit approx 45 anticlockwise Fig B 2 If there is an old battery in the sensor Remove this battery You need to wait about 2 minutes before inserting the new battery to allow the capacitor to discharge 3 Insert the new battery as shown in Fig C The battery should make contact with the side contact of the battery holder Push the battery gently until it clicks in place Make sure the battery is the right way round on top visible when inserted Make sure there is no grease on the battery 4 When the battery is inserted the light sensor spends the first 30 seconds sending special programming telegrams so that it can be identified in the system The LED will flash during this process Installation instructions Light Sensor DALI LS ADVANCED Page 3 OSRAM Flat battery indicator The LED in
6. sor may be operated in all EU and EFTA states Installation instructions Light Sensor DALI LS ADVANCED Page 7 OSRAM 7 Technical data Power supply Battery 3V DC 1 x lithium cell CR 2450N Transmission frequency 433 42 MHz ASK Range Coding Type of protection Temperature range Relative humidity Brightness Dimensions x H max 100 m in the open gt 1 billion possibilities IP 20 5 C to 55 C max 65 no condensation approx 3 Ix to 2000 Ix 52 mm x 23 mm Date 13 09 02 Light Sensor ADVANCED Version 1 0 Page 8 Subject to change without notice Errors and omission excepted Installation instructions Light Sensor DALI LS ADVANCED
7. tegrated in the light sensor Fig A 3 can only be seen in darkness It flashes about three times whenever a transmission is made If the LED flashes about ten times this indicates that the battery is almost flat LowBatt and has to be replaced Important Keep batteries away from children If a battery is swallowed seek medical attention immediately Replace the battery with one of the same type The old battery should be removed immediately and disposed of properly 3 Programming in the ADVANCED central unit The light sensor must be trained for lighting control in the central unit so that the central unit can identify the sensor as part of its system The actual function of the sensor is assigned to the central unit by the manual programming unit MPU gt see also the operating instructions for the manual programming unit A light sensor can only be assigned to one group of the lighting control system A maximum of eight light sensors or combined sensors can be integrated in the system Procedure 1 Remove the battery from the light sensor allow enough time for the capacitor to discharge 2 On the manual programming unit MPU start the radio startup programming mode 3 Insert the battery again The light sensor will now transmit special programming telegrams for approx 30 seconds to which the manual programming unit will react light sensor found On the MPU enter the number of the luminaire group to be controlled b
8. y this sensor 4 Terminate the radio startup procedure on the MPU This completes the programming process Notes When you enter the group on the MPU the message programming will appear This message does not disappear until the light sensor stops sending programming telegrams up to 30 seconds after the battery has been inserted During this time no other functions can be performed by the system We recommend that you label the light sensor with the device number indicated on the MPU and enter this number in the documentation for the lighting system Deleting the sensor in the DALI ADVANCED central unit Trained devices can be deleted via the MPU gt see the operating instructions for the manual programming unit Page 4 Installation instructions Light Sensor DALI LS ADVANCED OSRAM amp 4 Installation Electrical equipment may only be installed by qualified electricians The light sensor is installed on the ceiling above an illuminated work area Fig D Make sure the sensor is not exposed to direct light Note Do not attach the light sensor to the base plate until you have inserted the battery and trained the sensor in the central unit Installation 1 Detach the light sensor from the base plate by turning the unit Abb D approx 45 anticlockwise 1 7m 2 5m N Install the base plate directly on the ceiling using the screw provided Fig E1 or the adhesive pad oO Turn the
Download Pdf Manuals
Related Search
Related Contents
CONTENTS - CPD Solutions JVC GC-S1 Digital Camera User Manual E5024 ECDIS System Bedienungs-Anleitung BeachTek DXA-8 User's Manual 11 - Provincia di Torino 313905B - Supply Systems, Operation, French LG WD-10130(5)F User's Manual be.ez LArobe 2Green 15.4" Poulan 530085855 Trimmer User Manual Copyright © All rights reserved.